On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - OVERALL LEVEL MODE, the user can select either DIGITAL or ANALOG.
|
|
- Nicholas Elvin Hopkins
- 5 years ago
- Views:
Transcription
1 Title: Analog vs Digital for Overall Measurement Product: Data Collectors Program: 2115/2117 Version: Not Applicable Technology: Vibration Technote Number: On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - OVERALL LEVEL MODE, the user can select either DIGITAL or ANALOG. The Overall value, calculated in DIGITAL mode, will calculate the value from the low frequency cutoff to the maximum frequency specified. In other words, the overall is calculated over the defined frequency range of the spectrum. The Overall calculated in ANALOG mode will calculate the value from 2 Hz to the bandwidth of the instrument ( khz, khz, khz). The Analog overall value is sometimes referred to as an Unfiltered reading and is calculated from the waveform.
2 Title: Analog vs Digital Integration Mode for Measurement Product: Application Notes Program: App Notes Version: Not Applicable Technology: Vibration Technote Number: On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - SIGNAL INTEGR MODE there is the choice of ANALOG or DIGITAL. ANALOG integration integrates data in the waveform then performs the FFT - Fast Fourier Transform. The end result is that the waveform stored is in the integrated units and the spectrum is stored in the integrated units. DIGITAL integration performs the FFT first then the integration is performed on the spectrum. The end result is that the waveform is stored in the raw units of the sensor and the spectrum is stored in the integrated units. A common setup is to use an Accelerometer and integrate the signal to Velocity units. If DIGITAL integration is used then the waveform will be stored in G's and the spectrum will be stored in IN/SEC. However, one disadvantage to using DIGITAL integration is low frequencies will be enhanced. This causes a "ski slope" effect or "integration leg" on the low end of the spectrum. Typically this does not cause a problem unless the user is analyzing slow speed machinery. The ANALOG integration steps are: 1. The Waveform is collected in Acceleration units of G's 2. The Integration is performed on the waveform. 3. The last Waveform collected is stored in Velocity units of IN/SEC 4. The FFT is performed. 5. The averaged spectrum is stored in Velocity units of IN/SEC The DIGITAL integration steps are:
3 1. The Waveform is collected in Acceleration units of G's 2. The last Waveform collected is stored in Acceleration units of G's 3. The FFT is performed. 4. The spectrum is averaged in Acceleration units of G's 5. The Integration is performed on the spectrum 6. The averaged spectrum is stored in Velocity units of IN/SEC
4 Title: Analog/Digital Overall/Integration - 4 Cases, 1 Exception Product: Application Notes Program: App Notes Version: Not Applicable Technology: Vibration Technote Number: Four possible cases for setup include: Overall Level Mode: Digital Digital Analog Analog Signal Integr Mode: Analog Digital Analog Digital If a customer indicates overall measurement in the data collector shows as digital, but upon checking setup in collector for overall measurement mode he has actually chosen analog. For overall mode in analog, the frequency range for data acquisition is 2 Hz to 20 Khz. For overall mode in digital, the frequency range is 2 x delta f to the F max specified in the analysis parameter set. For integration mode in analog, the initial waveform signal is integrated when collected. The waveform is then stored in the integrated units. The FFT is applied to this waveform to get the spectrum. Since integration is performed on waveform, the mathematical amplification of spectrum at low frequencies is eliminated. For integration mode in digital, the waveform is collected and an FFT is applied to it to get the spectrum. This spectrum is then digitally integrated to get required result. The waveform is saved in native units of sensor, but "ski slope" has been introduced at low frequencies of spectrum. The Exception: Assuming integration is being performed on the point, with the combination of analog overall and digital integration modes, the expected result does not occur. The overall measurement is saved in digital not analog. This is because to get an analog overall, an analog integrated time waveform is required. The waveform is already in digital mode to get the requested digital spectrum. In this situation the customer wanted overall in analog to be able to have any high frequency abnormalities indicated be trending overall values. The integration was in digital to keep waveform units in sensor units, Gs in this case.
5 CSI's recommendation is to take overall in digital and specify Fmax large enough to encompass the frequencies in question.usually, problems occurring at high frequencies are so small that 1xRPM or other multiples will mask any changes. CSI now has the ability to save 12 trend parameters and this should be adequate to include any high frequency bands. The integration mode should be in analog to eliminate amplification of values at low frequencies. A special time waveform may be specified to be collected in the analysis parameter set. This special time waveform will replace the original after FFT is performed, and can be specified to be collected in native units of sensor.
6 Title: Why Analog Overall is not recommended when collecting PeakVue Data Product: Application Notes Program: App Notes Version: Technology: Vibration Technote Number: A customer asks what the difference is in the Overall collection mode and how it affects PeakVue data. The signal processing method is the same whether Digital or Analog Overall is used. The spectrums shown below were collected on a rotor kit without moving the accelerometer, just the overall parameter was changed. The top spectrum was in Analog Overall and shows a value of.1246 G's as compared to the lower spectrum collected in Digital which is shown at.0540 G's. The Analog Overall will calculate a value from Fmin to the high end of the frequency response of the accelerometer. The Digital Overall will calculate a value from the Fmin to Fmax but because the HP Filter is set to 1KHz those values are filtered out and not included in the overall calculation. Accel-Accel 500Hz Fmax 1000 HZ HP filter used for PeakVue 1 Average Also note that the spectrums below taken from the rotor kit show all the energy below the High Pass FIlter selection. If no energy is present both Overall values could be very close.
7 The above spectrum was collected with Analog Overall
8 The above spectrum was collected with Digital RMS Overall
Also, side banding at felt speed with high resolution data acquisition was verified.
PEAKVUE SUMMARY PeakVue (also known as peak value) can be used to detect short duration higher frequency waves stress waves, which are created when metal is impacted or relieved of residual stress through
More informationPeakVue Analysis for Antifriction Bearing Fault Detection
Machinery Health PeakVue Analysis for Antifriction Bearing Fault Detection Peak values (PeakVue) are observed over sequential discrete time intervals, captured, and analyzed. The analyses are the (a) peak
More informationPresentation at Niagara Falls Vibration Institute Chapter January 20, 2005
Monitoring Gear Boxes with PeakVue Presentation at Niagara Falls Vibration Institute Chapter January 20, 2005 1 WHAT IS A STRESS WAVE? 2 Hertz Theory Prediction for Various Size Metal Balls 3 Frequencies
More informationIMPACT DEMODULATION. An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults
IMPACT DEMODULATION An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults 2018 by Azima. All Rights Reserved. Part Number: 80004240-1 AZIMA DLI HEADQUARTERS: 300 Trade Center, Suite
More informationCSI 9330 Vibration Transmitter
Machinery Health Management O-9330-110512 Product Data Sheet November 2012 CSI 9330 Vibration Transmitter n Continuously monitors critical machinery in process applications and other industrial environments
More informationSC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)
SC200 Series Signal Conditioner MNX10020, REV H 10/17/2012 1 CONTENTS SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical...
More informationCapacitive MEMS accelerometer for condition monitoring
Capacitive MEMS accelerometer for condition monitoring Alessandra Di Pietro, Giuseppe Rotondo, Alessandro Faulisi. STMicroelectronics 1. Introduction Predictive maintenance (PdM) is a key component of
More informationTesting Sensors & Actors Using Digital Oscilloscopes
Testing Sensors & Actors Using Digital Oscilloscopes APPLICATION BRIEF February 14, 2012 Dr. Michael Lauterbach & Arthur Pini Summary Sensors and actors are used in a wide variety of electronic products
More informationShaft Vibration Monitoring System for Rotating Machinery
2016 Sixth International Conference on Instrumentation & Measurement, Computer, Communication and Control Shaft Vibration Monitoring System for Rotating Machinery Zhang Guanglin School of Automation department,
More informationCASE STUDY: Roller Mill Gearbox. James C. Robinson. CSI, an Emerson Process Management Co. Lal Perera Insight Engineering Services, LTD.
CASE STUDY: Roller Mill Gearbox James C. Robinson CSI, an Emerson Process Management Co. Lal Perera Insight Engineering Services, LTD. ABSTRACT Stress Wave Analysis on a roller will gearbox employing the
More informationCONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS
SENSORS FOR MACHINERY HEALTH MONITORING WHITE PAPER #47 CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS www.pcb.com/imi-sensors imi@pcb.com 800.828.8840 Continuous Condition
More informationCSI 9420 Wireless Vibration Transmitter
Machinery Health Management O-9420 Product Data Sheet August 2010 CSI 9420 Wireless Vibration Transmitter n Accurately monitors vibration and temperature in hard-toreach locations n Provides complete vibration
More informationMTN/8066/G-MAC VIBRATION MODULE
Monitran Ltd. Monitor House, Hazlemere Road Penn, Bucks. HP10 8AD England Tel: +44 (0) 1494 816569 Fax: +44 (0) 1494 812256 E-Mail: info@monitran.co.uk Web Site: www.monitran.co.uk MTN/8066/G-MAC VIBRATION
More informationCSI 9420 Wireless Vibration Transmitter
Machinery Health Management O-9420 Product Data Sheet November 2012 CSI 9420 Wireless Vibration Transmitter n Accurately monitors vibration and temperature in hard-to-reach locations n Provides complete
More information9330 Vibration Transmitter
Reliability Solutions Product Data Sheet June 2017 9330 Vibration Transmitter Continuously monitors critical machinery in process applications and other industrial environments Interfaces with existing
More informationPioneering Partnership Performance
Pioneering Partnership Performance Born for In-Field Testing Impaq Elite is a portable 4 channel real-time analyzer that is built for advanced noise and vibration test in the field. Unique features like
More informationVibration based condition monitoring of rotating machinery
Vibration based condition monitoring of rotating machinery Goutam Senapaty 1* and Sathish Rao U. 1 1 Department of Mechanical and Manufacturing Engineering, Manipal Institute of Technology, Manipal Academy
More informationUnderstanding Discrepancies in Vibration Amplitude Readings Between Different Instruments
Understanding Discrepancies in Vibration Amplitude Readings Between Different Instruments Part of 2 Steve Sabin Editor, ORBIT magazine GE Energy steve.sabin@ge.com 8 ORBIT [Vol.25 No.2 25] Introduction
More informationCSI 9420 Wireless Vibration Transmitter
Machinery Health Management Product Data Sheet August 2016 CSI 9420 Wireless Vibration Transmitter Accurately monitors vibration and temperature in hard-to-reach locations Provides complete vibration data
More informationWIRELESS ASSET MONITORING
WIRELESS ASSET MONITORING WITH ANALYSIS AND DATABASE TRANSLATOR SOFTWARE WAM 661 WAM 761 WAM 32U (pending) Rev. 5/10 WAM WIRELESS ASSET MONITORING SYSTEM OVERVIEW: Spectrum Instruments Ltd s WAM product
More informationErrata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition
Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition Correction Sheet #1 Issued 01 July 2018 Copyright 2018 by NEBB All rights reserved. Published 2018. Printed in the United
More informationIntroduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*
IntroductiontoMachineryVibrationSheetAnswer Chapter1:VibrationsSourcesandUses 1. 1. imposed motions related to the function - e.g. slider crank and earn 2. inadequate design - e.g. resonance 3. manufacturing
More informationIndustrial vibration sensor selection: piezovelocity transducers
Industrial vibration sensor selection: piezovelocity transducers In many industrial monitoring applications, piezovelocity transducers have distinct advantages over piezoelectric accelerometers and traditional
More informationIntroduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed
SPECTRUM ANALYZER Introduction A spectrum analyzer measures the amplitude of an input signal versus frequency within the full frequency range of the instrument The spectrum analyzer is to the frequency
More informationLION. TechNote LT September, 2014 PRECISION. Understanding Sensor Resolution Specifications and Performance
LION PRECISION TechNote LT05-0010 September, 2014 Understanding Sensor Resolution Specifications and Performance Applicable Equipment: All noncontact displacement sensors Applications: All noncontact displacement
More informationMachine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers
Machine Data Acquisition Powerful vibration data collectors, controllers, sensors, and field analyzers CHOOSE THE PERFECT HARDWARE DESIGN SUITED FOR YOU BRAUN, BRAINS AND BEAUTY TOTAL TRIO IS A COMPLETE
More informationIndustrial vibration sensor selection: Piezovelocity transducers
Industrial vibration sensor selection: Piezovelocity transducers In many industrial monitoring applications, piezovelocity transducers have distinct advantages over piezoelectric accelerometers and traditional
More informationPanasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD
Panasonic, 2 Channel FFT Analyzer VS-3321A DC to 200kHz,512K word memory,and 2sets of FDD New generation 2CH FFT Anal General The FFT analyzer is a realtime signal analyzer using the Fast Fourier Transform
More informationVibration Data Collector Signal Analysis
Vibration Data Collector Signal Analysis James Zhuge, Ph.D., President Crystal Instruments Corporation 2370 Owen Street Santa Clara, CA 95054, USA www.go-ci.com (Part of VDC User s Manual) 3/16/2009 COPYRIGHT
More informationVIBRATION DATA COLLECTOR SIGNAL ANALYSIS
CI PRODUCT NOTE No. 019 VIBRATION DATA COLLECTOR SIGNAL ANALYSIS WWW.CRYSTALINSTRUMENTS.COM Dynamic Signal Analysis in Vibration Data Collector The CoCo-80/90 provides two different user interfaces for
More informationUnstable Reading of Accelerometers in Cryogenic Service. Cryodynamics Division
Unstable Reading of Accelerometers in Cryogenic Service Francisco Marquez Head Condition Monitoring Operations Technical Dept. RasGas Robert Mollath Project Engineer Ebara International Corp Cryodynamics
More informationAMS 9420 Wireless Vibration Transmitter
Reliability Solutions Product Data Sheet April 2018 AMS 9420 Wireless Vibration Transmitter Accurately monitors vibration and temperature in hard-to-reach locations Provides complete vibration data including
More informationME scope Application Note 02 Waveform Integration & Differentiation
ME scope Application Note 02 Waveform Integration & Differentiation The steps in this Application Note can be duplicated using any ME scope Package that includes the VES-3600 Advanced Signal Processing
More informationAGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 008 Vibration DESCRIPTION Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance
More informationVIBRATION MONITORING OF VERY SLOW SPEED THRUST BALL BEARINGS
VIBRATION MONITORING OF VERY SLOW SPEED THRUST BALL BEARINGS Vipul M. Patel and Naresh Tandon ITMME Centre, Indian Institute of Technology, Hauz Khas, New Delhi 110016, India e-mail: ntandon@itmmec.iitd.ernet.in
More informationSVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION. SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK
SVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK SVAN 958A DESCRIPTION OF GROUND VIBRATION FUNCTION 2 Note: The ground vibration mode may require FFT analysis
More informationCEC VIBRATION TRANSMITTER
CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:
More informationShaft Absolute Vibration Monitor Specifications
Shaft Absolute Vibration Monitor Specifications The Shaft Absolute Vibration Monitor is designed for high reliability for the plant s most critical rotating machinery. This 1-slot monitor is used together
More informationSHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 17. Aliasing. Again, engineers collect accelerometer data in a variety of settings.
SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 17. Aliasing By Tom Irvine Email: tomirvine@aol.com Introduction Again, engineers collect accelerometer data in a variety of settings. Examples include:
More informationHG4930 INERTIAL MEASUREMENT UNIT (IMU) Performance and Environmental Information
HG493 INERTIAL MEASUREMENT UNIT () Performance and Environmental Information HG493 Performance and Environmental Information aerospace.honeywell.com/hg493 2 Table of Contents 4 4 5 5 6 7 8 9 9 9 Honeywell
More informationStatistical analysis of low frequency vibrations in variable speed wind turbines
IOP Conference Series: Materials Science and Engineering OPEN ACCESS Statistical analysis of low frequency vibrations in variable speed wind turbines To cite this article: X Escaler and T Mebarki 2013
More informationORBIGate The Turbomachinery Vibration Software
ORBIGate DATASHEET DATASHEET ORBIGate The Turbomachinery Vibration Software Introduction ORBIGate is the OROS portable and dedicated solution for the measurement of industrial rotating machinery vibration.
More informationWHITE PAPER. Continuous Condition Monitoring with Vibration Transmitters and Plant PLCs
WHITE PAPER Continuous Condition Monitoring with Vibration Transmitters and Plant PLCs Visit us online at www.imi-sensors.com Toll-Free in USA 800-959-4464 716-684-0003 Continuous Condition Monitoring
More informationUNIT-3. Electronic Measurements & Instrumentation
UNIT-3 1. Draw the Block Schematic of AF Wave analyzer and explain its principle and Working? ANS: The wave analyzer consists of a very narrow pass-band filter section which can Be tuned to a particular
More informationBLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 2: RESAMPLING TO IMPROVE EFFECTIVE DYNAMIC RANGE
BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 2: RESAMPLING TO IMPROVE EFFECTIVE DYNAMIC RANGE Kenneth P. Maynard, Martin Trethewey Applied Research Laboratory, The Pennsylvania
More informationGV-700 VIBE PORT. Installation and. Operating Manual
GV-700 VIBE PORT Installation and Operating Manual This document may not be reproduced in any way without the prior written permission of the company. August 2016 2 GV - 700T TRANSMITTER GV - 701R RECEIVER
More informationThe Battle for Data Fidelity:Understanding the SFDR Spec
The Battle for Data Fidelity:Understanding the SFDR Spec As A/D converters (ADC) and data acquisition boards increase their bandwidth, more and more are including the spurious free dynamic range (SFDR)
More informationGetting Started. MSO/DPO Series Oscilloscopes. Basic Concepts
Getting Started MSO/DPO Series Oscilloscopes Basic Concepts 001-1523-00 Getting Started 1.1 Getting Started What is an oscilloscope? An oscilloscope is a device that draws a graph of an electrical signal.
More informationCASE STUDY: Rotor Bar Fault in AC Induction
Dwight Bradshaw General Manager DBradshaw@VoyagerInstruments.com Office: 970.232.9344 Cell: 970.412.8264 VoyagerInstruments.com CASE STUDY: Pioneer Engineering is a leading engineering services company
More informationVibration Analysis on Rotating Shaft using MATLAB
IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 06 December 2016 ISSN (online): 2349-784X Vibration Analysis on Rotating Shaft using MATLAB K. Gopinath S. Periyasamy PG
More informationSignals & Systems for Speech & Hearing. Week 6. Practical spectral analysis. Bandpass filters & filterbanks. Try this out on an old friend
Signals & Systems for Speech & Hearing Week 6 Bandpass filters & filterbanks Practical spectral analysis Most analogue signals of interest are not easily mathematically specified so applying a Fourier
More informationOverall vibration, severity levels and crest factor plus
Overall vibration, severity levels and crest factor plus By Dr. George Zusman, Director of Product Development, PCB Piezotronics and Glenn Gardner, Business Unit Manager, Fluke Corporation White Paper
More informationTroubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most commonly
More informationDeveloper Techniques Sessions
1 Developer Techniques Sessions Physical Measurements and Signal Processing Control Systems Logging and Networking 2 Abstract This session covers the technologies and configuration of a physical measurement
More informationEET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS
EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS Experimental Goals A good technician needs to make accurate measurements, keep good records and know the proper usage and limitations of the instruments
More informationComparison of Transmissibility of Non-Metallic Materials For Vibration Isolation
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X PP. 57-61 www.iosrjournals.org Comparison of Transmissibility of Non-Metallic Materials For Vibration A.
More informationNeurophysiology. The action potential. Why should we care? AP is the elemental until of nervous system communication
Neurophysiology Why should we care? AP is the elemental until of nervous system communication The action potential Time course, propagation velocity, and patterns all constrain hypotheses on how the brain
More informationBiomechanical Instrumentation Considerations in Data Acquisition ÉCOLE DES SCIENCES DE L ACTIVITÉ PHYSIQUE SCHOOL OF HUMAN KINETICS
Biomechanical Instrumentation Considerations in Data Acquisition Data Acquisition in Biomechanics Why??? Describe and Understand a Phenomena Test a Theory Evaluate a condition/situation Data Acquisition
More informationUsing Spectral Analysis to Determine the Resonant Frequency of Vibrating Wire Gages HE Hu
4th International Conference on Machinery, Materials and Computing Technology (ICMMCT 2016) Using Spectral Analysis to Determine the Resonant Frequency of Vibrating Wire Gages HE Hu China Institute of
More informationPresented By: Michael Miller RE Mason
Presented By: Michael Miller RE Mason Operational Challenges of Today Our target is zero unplanned downtime Maximize Equipment Availability & Reliability Plan ALL Maintenance HOW? We are trying to be competitive
More informationDynamic Angle Estimation
Dynamic Angle Estimation with Inertial MEMS Analog Devices Bob Scannell Mark Looney Agenda Sensor to angle basics Accelerometer basics Accelerometer behaviors Gyroscope basics Gyroscope behaviors Key factors
More informationLaboratory Test of Vibration of Micro/Nano Satellite for Environment Test Standardization
Laboratory Test of Vibration of Micro/Nano Satellite for Test Standardization Amgalanbat Batsuren, Toru Hatamura, Hirokazi Masui, Mengu Cho Interaction Kyushu Institute of Technology 5 th Nano Satellite
More informationSensor Portfolio for Machinery Health Applications
Machinery Health Management Product Data Sheet March 2014 Sensor Portfolio for Machinery Health Applications One source of responsibility for the entire measurement chain measurements Unique sensors co-developed
More informationEnhanced API 670 monitoring of gearboxes
Application Note Enhanced API 670 monitoring of gearboxes Use of SKF acceleration enveloping with the On-line System DMx By Chris James SKF Reliability Systems and Oscar van Dijk SKF Reliability Systems
More informationLaboratory Experiment #1 Introduction to Spectral Analysis
J.B.Francis College of Engineering Mechanical Engineering Department 22-403 Laboratory Experiment #1 Introduction to Spectral Analysis Introduction The quantification of electrical energy can be accomplished
More informationCardVibro Neo Model : VM-2004Neo
CardVibro Neo Model : VM-2004Neo IMV CORPORATION CardVibro Neo, VM-2004Neo succeeds the excellent basic features of CardVibro VM-2001 and is improved to be used with Pocket PC. Features Conforms to the
More informationmetro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.
metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD. Product brocure 1 is reliable, fast and easiest to use tool designed for routine
More informationFAG Detector III The solution for monitoring and balancing. Technical Product Information
FAG III The solution for monitoring and balancing Technical Product Information Principle Operation High functionality Simple handling The FAG III is a vibration measuring device, data collector and operational
More informationSCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL
SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL Section Description Page 1.0 Introduction 1 2.0 CE Compliance 1 3.0 Features and theory of operation 1 4.0 The High Pass filter and the Low Pass Bessel
More informationExperiment 2: Electronic Enhancement of S/N and Boxcar Filtering
Experiment 2: Electronic Enhancement of S/N and Boxcar Filtering Synopsis: A simple waveform generator will apply a triangular voltage ramp through an R/C circuit. A storage digital oscilloscope, or an
More informationVibration Fundamentals Training System
Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals An Ideal Tool for Optimizing Your Vibration Class Curriculum The Vibration Fundamentals Training System
More informationChapter 1: Introduction. EET-223: RF Communication Circuits Walter Lara
Chapter 1: Introduction EET-223: RF Communication Circuits Walter Lara Introduction Electronic communication involves transmission over medium from source to destination Information can contain voice,
More informationTransfer Function (TRF)
(TRF) Module of the KLIPPEL R&D SYSTEM S7 FEATURES Combines linear and nonlinear measurements Provides impulse response and energy-time curve (ETC) Measures linear transfer function and harmonic distortions
More informationAnalogue Signals. M J Brockway. February 5, 2018
Analogue Signals M J Brockway February 5, 2018 Digital vs Analogue Digital (electrical) inputs to a CPU register as logical values - true or false, 1 or 0, on or off. typically arise from switch contacts
More informationAdvantages of Analog Representation. Varies continuously, like the property being measured. Represents continuous values. See Figure 12.
Analog Signals Signals that vary continuously throughout a defined range. Representative of many physical quantities, such as temperature and velocity. Usually a voltage or current level. Digital Signals
More informationXMV16 / XIO16T Extended vibration monitoring card pair XMV16
Extended vibration monitoring card pair XMV16 FEATURES» From the Vibro-Meter product line» Designed for operation with the VibroSight software total monitoring solution» 16 dynamic vibration channels and
More informationSignalCalc Drop Test Demo Guide
SignalCalc Drop Test Demo Guide Introduction Most protective packaging for electronic and other fragile products use cushion materials in the packaging that are designed to deform in response to forces
More informationFundamentals of Vibration Measurement and Analysis Explained
Fundamentals of Vibration Measurement and Analysis Explained Thanks to Peter Brown for this article. 1. Introduction: The advent of the microprocessor has enormously advanced the process of vibration data
More informationApplications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems
Bently Nevada* Asset Condition Monitoring Connecting SCOUT to Continuous Monitoring Systems The most effective installations of continuous monitoring instruments such as the 3500 system include integration
More informationReal-Time FFT Analyser - Functional Specification
Real-Time FFT Analyser - Functional Specification Input: Number of input channels 2 Input voltage ranges ±10 mv to ±10 V in a 1-2 - 5 sequence Autorange Pre-acquisition automatic selection of full-scale
More informationAero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.
4-170 Piezoelectric Accelerometer The CEC 4-170 accelerometer is a self-generating, piezoelectric accelerometer designed for medium temperature vibration measurement applications. This instrument provides
More informationUnraveling Zero Crossing and Full Spectrum What does it all mean?
Unraveling Zero Crossing and Full Spectrum What does it all mean? Ian Agranat Wildlife Acoustics, Inc. 2 nd Symposium on Bat Echolocation Research, Tucson AZ March 29, 2017 Let s start with a sound wave
More informationLab 2b: Dynamic Response of a Rotor with Shaft Imbalance
Lab 2b: Dynamic Response of a Rotor with Shaft Imbalance OBJECTIVE: To calibrate an induction position/displacement sensor using a micrometer To calculate and measure the natural frequency of a simply-supported
More informationResponse spectrum Time history Power Spectral Density, PSD
A description is given of one way to implement an earthquake test where the test severities are specified by time histories. The test is done by using a biaxial computer aided servohydraulic test rig.
More informationSave Money and Decrease Downtime with Vehicle and Equipment Monitoring. Embedded Technology Summit National Instruments
Save Money and Decrease Downtime with Vehicle and Equipment Monitoring Embedded Technology Summit National Instruments Costa Allegra Types of Vehicle Monitoring Propulsion Task Based Collateral Damage
More informationAs Published on EN-Genius.net
Analysis and Measurement of Intrinsic Noise in Op Amp Circuits Part IX: 1/f Noise and Zero-Drift Amplifiers by Art Kay, Senior Applications Engineer, Texas Instruments Incorporated This TechNote focuses
More informationGraph Matching. walk back and forth in front of. Motion Detector
Graph Matching One of the most effective methods of describing motion is to plot graphs of position, velocity, and acceleration vs. time. From such a graphical representation, it is possible to determine
More informationAMS 2140 Machinery Health Analyzer
Reliability Solutions Product Data Sheet AMS 2140 Machinery Health Analyzer Easy data collection and powerful analysis tools in a single unit Four-channel data collection for faster route completion and
More informationDetection of an Inner Race Defect Using PeakVue
Detection of an Inner Race Defect Using PeakVue By: Aubrey Green, Lead Analyst In early January of 2012, I assumed the responsibilities of the vibration analysis program at a customer s site that had been
More informationFrom Digital to RF Debugging in the Time and Frequency Domain. Embedded Systems Conference 2015 May 6-7, 2015
From Digital to RF Debugging in the Time and Frequency Domain Embedded Systems Conference 2015 May 6-7, 2015 Agenda In this seminar we ll discuss ı The challenges of debugging mixed domain embedded systems
More informationEmbedded Surface Mount Triaxial Accelerometer
Embedded Surface Mount Triaxial Accelerometer Robert D. Sill Senior Scientist PCB Piezotronics Inc. 951 Calle Negocio, Suite A San Clemente CA, 92673 (877) 679 0002 x2954 rsill@pcb.com Abstract 18566 59
More informationVCSO Mechanical Shock Compensation
VCSO Mechanical Shock Compensation Who are we? Team members: Max Madore Joseph Hiltz-Maher Shaun Hew Shalin Shah Advisor: Helena Silva Phonon contact: Scott Kraft Project Overview VCSO and mechanical vibration
More informationAn Introduction to Time Waveform Analysis
An Introduction to Time Waveform Analysis Timothy A Dunton, Universal Technologies Inc. Abstract In recent years there has been a resurgence in the use of time waveform analysis techniques. Condition monitoring
More informationChapter 2 Analog-to-Digital Conversion...
Chapter... 5 This chapter examines general considerations for analog-to-digital converter (ADC) measurements. Discussed are the four basic ADC types, providing a general description of each while comparing
More informationFrequency Response Analysis of Deep Groove Ball Bearing
Frequency Response Analysis of Deep Groove Ball Bearing K. Raghavendra 1, Karabasanagouda.B.N 2 1 Assistant Professor, Department of Mechanical Engineering, Bellary Institute of Technology & Management,
More informationSistemas de Aquisição de Dados. Mestrado Integrado em Eng. Física Tecnológica 2015/16 Aula 3-29 de Setembro
Sistemas de Aquisição de Dados Mestrado Integrado em Eng. Física Tecnológica 2015/16 Aula 3-29 de Setembro Aliasing Example fsig=101khz fsig=899 khz All sampled signals are equal! fsig=1101 khz 2 How to
More informationSetting up a Multi sine impedance measurement
Setting up a Multi sine impedance measurement Case study: how do I setup a Multi Sine impedance measurement? 1 Single sine vs Multi sine Traditional electrochemical impedance spectroscopy measurements
More informationCOMPARATIVE STUDY OF VIBRATION ISOLATORS USING PARAMETER TRANSMISSIBILITY
COMPARATIVE STUDY OF VIBRATION ISOLATORS USING PARAMETER TRANSMISSIBILITY Sushil Ramdas Deore 1, Mohammad Safi A Patan 2, Prof. R.S.Pawar 3 1,2,3 Department of mechanical engineering, G.E.S.R.H.S. College
More informationTrendmaster * Dynamic Scanning Module
149744 Trendmaster * Dynamic Scanning Module Product Datasheet Bently Nevada * Asset Condition Monitoring Description The 149744 Trendmaster* Dynamic Scanning Module (DSM) is a compact rack-based data
More informationTool Condition Monitoring using Acoustic Emission and Vibration Signature in Turning
, July 4-6, 2012, London, U.K. Tool Condition Monitoring using Acoustic Emission and Vibration Signature in Turning M. S. H. Bhuiyan, I. A. Choudhury, and Y. Nukman Abstract - The various sensors used