1 Proposed Hydropower Archimedean Screw Osney Lock and Weir, Oxford Noise Impact Assessment TECHNICAL REPORT

2 Hydropower Archimedean Screw Noise Impact Assessment Prepared for: The Low Carbon Hub, 23 Park End Street, Oxford OX1 1HU Site address: Osney Lock and Weir, Oxford Table of Contents 1 INTRODUCTION DEVELOPMENT SITE NOISE CRITERIA... 3 NATIONAL PLANNING POLICY FRAMEWORK... 3 BS4142:1997 RATING INDUSTRIAL NOISE IN MIXED RESIDENTIAL AND INDUSTRIAL AREAS... 3 WORLD HEALTH ORGANISATION GUIDELINES FOR COMMUNITY NOISE ENVIRONMENTAL NOISE STUDY... 6 ASSESSMENT OF BACKGROUND NOISE LEVELS SOURCE NOISE STUDY... 9 PREDICTION OF NOISE FROM MECHANICAL PLANT (NOISE MODELLING) NOISE ASSESSMENT CONCLUSIONS Appendix A: Appendix B: Appendix C: Appendix D: Glossary of Acoustic Terms... I Noise Measurement Locations... III Scheme Design... VI Noise Survey Summary... VII

3 PO Box 755, Capel St Mary, Ipswich, Suffolk IP9 2WF Tel No: Fax No: VAT No Registration No Registered Address: 57 Thorney Road, Capel St. Mary, Ipswich IP9 2XH SSC PROJECT NO: STATUS SIGNATURE / NAME / POSITION DATE ORIGINATED Steve Skingle BSc. (Hons) MAES MIOA Senior Acoustic Consultant 28 th September 2012 Revision R1 APPROVED DOC REFERENCE Mark Page MIOA Managing Director R1 28 th September 2012 Revision R1

4 INTRODUCTION 1 1 INTRODUCTION 1.1 Sound Solution Consultants Limited were commissioned to undertake a noise assessment of a proposed renewable energy development at Osney Lock and Weir; to establish the noise impact of mechanical plant proposals on those in the vicinity of the development. 1.2 A noise survey has been requested to supplement a prospective planning application for hydropower development at Osney Lock and Weir. Consultation with the Environmental Health Department of Oxford City Council has highlighted that the prospect of planning permission being granted is dependent on the applicant addressing impact on neighbours. One issue that requires assessment includes the impact of noise on surrounding noise sensitive locations. 1.3 The objective of this study is to quantify the acoustic environment in the vicinity of the existing site by carrying out a noise assessment using the methodology outlined in BS4142:1997. Further guidance is to be advised considering the World Health Organisation Guidance for Community Noise.

5 DEVELOPMENT SITE 2 2 DEVELOPMENT SITE 2.1 The development site is a triangular shaped island bound by the River Thames to the north and Osney Weir Pool to the south; as shown in the block plan in Appendix B. The proposal is to locate a hydropower scheme in the south west corner of the site, to utilise the flow of water across the existing lock and generate a sustainable source of electricity for the local community. 2.2 The scheme incorporates an Archimedean screw positioned across the fall of the lock, along with a fish pass and main building containing a generator. The development only operates where there is sufficient flow over the lock as to turn the screw and generator; which is rated to produce up to 30kW of electrical power. 2.3 The noise sensitive locations of Bridge Street lie west of the mechanical plant proposals and with line-of-site to the development. The nearest residence of No. 47 Bridge Street is nominally 22m from the proposed building and mechanical plant locations. South of the development site lies the Boat House, nominally 30m from the development, containing commercial premises. Adjacent to this property is the residential dwelling of the Lock House. 2.4 The following tasks have been undertaken as part of this noise assessment: Survey of noise levels about the application site, representing the ambient noise climate of properties closest to the proposed development. Measurement of noise levels of a similar Archimedean screw, representing the noise level of the development proposal. Calculation of noise levels from the proposed scheme at the nearest noise sensitive locations using specific noise data from a similar scheme and noise modelling. Assessment of the background noise level with regard to the proposed development against the guidance provided by BS4142:1997 Rating industrial noise affecting mixed residential and industrial areas. 2.5 A glossary of acoustic terms is shown in Appendix A.

6 NOISE CRITERIA 3 3 NOISE CRITERIA NATIONAL PLANNING POLICY FRAMEWORK 3.1 The National Planning Policy Framework (NPPF) sets out the Government s planning policies for England and how these are expected to be applied. It provides a framework where local Councils can produce their own local and neighbourhood plans, which reflect the needs of their communities. 3.2 In conserving and enhancing the natural environment, the planning system should prevent both new and existing development from contributing to, or being put at, unacceptable risk from environmental factors including noise. 3.3 Planning policies and decisions should aim to avoid noise giving rise to significant adverse impacts on health and quality of life as a result of new development. Conditions may be used to mitigate and reduce noise to a minimum so that adverse impacts on health and quality of life are minimised. Reference is made within NPPF to the Noise Policy Statement for England (NPSE) as published by DEFRA in March Consultation with Oxford City Council planning department has highlighted an absence of specific sustainable development standards and supplementary planning guidance with respect to industrial environmental noise and protection of residential amenity. Suitable noise guidance is taken from BS4142:1997 Rating Industrial Noise in Mixed Residential and Industrial Areas and the World Health Organisation Guidance for Community Noise. BS4142:1997 RATING INDUSTRIAL NOISE IN MIXED RESIDENTIAL AND INDUSTRIAL AREAS 3.5 The most relevant criteria to assess the impact of industrial noise levels on residential dwellings are contained within BS4142:1997 Rating industrial noise affecting mixed residential and industrial areas. This British Standard describes a method of determining the level of a noise of an industrial nature, together with procedures for assessing whether the noise in question is likely to give rise to complaints from persons living in the vicinity. 3.6 The likelihood of complaint in response to a noise depends on factors including the margin by which it exceeds the background noise level, its absolute level, time of day, change in the noise environment, as well as local attitudes to the premises and the nature of the neighbourhood. BS4142:1997 is only concerned with the rating of a noise of an industrial nature, based on the margin by which it exceeds a background noise level with an appropriate allowance for the acoustic features present in the noise. As this margin increases, so does the likelihood of complaint. 3.7 Certain acoustic features can increase the likelihood of complaint over that expected from a simple comparison between the specific noise level and the background noise level. Where present as part of the assessment, such features are taken into account by adding 5 db to the specific noise level to obtain the rating level:

7 NOISE CRITERIA 4 The noise contains a distinguishable, discrete, continuous note (whine, hiss, screech, hum, etc.); The noise contains distinct impulses (bangs, clicks, clatters, or thumps); The noise is irregular enough to attract attention. 3.8 The rating level is equal to the specific noise level if there are no such features present or expected to be present. 3.9 To assess the likelihood of complaints using BS4142:1997 the measured background noise level is subtracted from the rating level. The greater this difference the greater the likelihood of complaints, such as: A difference of around +10 db or more indicates that complaints are likely. A difference of around + 5 db is of marginal significance. If the rating level is more than 10 db below the measured background noise level then this is a positive indication that complaints are unlikely BS4142:1997 states that: The likelihood that an individual will complain depends on individual attitudes and perceptions in addition to the noise levels and acoustic features present. This standard makes no recommendations in respect of the extent to which individual attitudes and perceptions should be taken into account in any particular case. WORLD HEALTH ORGANISATION GUIDELINES FOR COMMUNITY NOISE 3.11 The scope of WHO Guidelines for Community Noise was to consolidate scientific knowledge on the health impacts of community noise, to provide guidance to environmental health authorities and professionals trying to protect people from the harmful effects of noise in nonindustrial environments. The health risk to human from exposure to environmental noise was evaluated and guidelines derived The WHO presents a measure to assess adverse health effects from steady-state anonymous noises such as traffic. There are no specific health guidelines for the influence of noises with specific character (i.e. tonality or intermittency), or with respect to specific sources of noise; such as industrial sources Internal design levels within the WHO guidelines are recommended in line with those mentioned in BS8233:1999: The effects of noise in dwellings, typically, are sleep disturbance, annoyance and speech interference. For bedrooms the critical effect is sleep disturbance. Indoor guideline values for bedrooms are 30 db LAeq for continuous noise... At night-time, outside sound levels about 1 metre from facades of living spaces should not exceed 45 db LAeq, so that people may sleep with

8 NOISE CRITERIA 5 bedroom windows open. This value was obtained by assuming that the noise reduction from outside to inside with the window open is 15 db. To enable casual conversation indoors during daytime, the sound level of interfering noise should not exceed 35 db LAeq In addition to the above: The capacity of a noise to induce annoyance depends upon its physical characteristics, including the sound pressure level, spectral characteristics and variations of these properties with time. During daytime, few people are highly annoyed at LAeq levels below 55 db(a), and few are moderately annoyed at LAeq levels below 50 db(a). Sound levels during the evening and night should be 5 10 db lower than during the day.

9 ENVIRONMENTAL NOISE STUDY 6 4 ENVIRONMENTAL NOISE STUDY 4.1 An environmental noise survey was undertaken over a weekday period from Tuesday 24 th July to Thursday 26 th July 2012, to sample existing background noise levels during different times of the day in accordance with BS4142:1997 and BS7445-1: The equipment used during the survey consisted of the following Type 1 and Class 1 precision noise monitoring equipment listed below. All equipment listed has traceable calibration history to relevant British Standards, valid in accordance with BS4142. Manufacturer Model No. Description Serial No. Calibration Date Larson Davis rd Octave Band Sound Level Meter /12 Larson Davis 902 Microphone pre-amplifier /12 Larson Davis 2541 ½ Condenser microphone /12 Larson Davis LxT Octave Band Sound Level Meter /10 Larson Davis PRMLXT1 Microphone pre-amplifier /10 Larson Davis 377B02 ½ Electret microphone /10 Larson Davis CAL200 Sound Level Calibrator /12 Table 1 Noise monitoring equipment. 4.3 The main sources of noise at the background measurement location consisted of water flow noise from Osney Lock and Weir, along with intermittent community noises in and around the measurement locations. 4.4 Ambient noise measurements were taken at a height of 1.5m from the ground in free-field conditions away from objects that would adversely affect the data measured; in accordance with the guidance contained within BS4142:1997 and BS7445-1: A brief description of the measurement positions are detailed below and shown on the annotated drawing and photographs in Appendix B: Position 1) North of the development site, on the bank of the river and in line with the rear of No. 46 Bridge Street. Noise measurements at this location were judged to be the same as those experienced at the nearest noise sensitive location of No. 47 Bridge Street, being equidistant from Osney Lock. Position 2) South of the development site at the west end of a handrail on the bank of the river. This noise measurement location was at least 3.5m from the Boat House with clear line-ofsite to the surrounding lock and weir. 4.6 The weather at the start of the noise survey was measured using a Kestrel 4500 weather station to be 25 C and 40% relative humidly, with a breeze less than 1m/s. Good measurement conditions were reported throughout the survey such that the weather conditions did not have significant adverse affects on the noise levels monitored.

10 ENVIRONMENTAL NOISE STUDY In line with the requirements of BS4142, the following lowest L A90,T noise levels are considered for the development. Given that ambient noise levels are reasonably constant over the measurement period from Tuesday 24 th July to Thursday 26 th July 2012; the lowest L A90,1hr level is taken at each measurement location as a baseline for noise assessment. Measurement Time Residual noise level Location Date BS4142:1997 Period HH:MM Free-field L A90, T P1 25/07/ :00 05:00 Lowest L A90, 1hr 57dB(A) P2 26/07/ :00 05:00 Lowest L A90, 1hr 66dB(A) Table 2 Lowest recorded L A90, T noise levels for noise assessment. 4.8 Daytime operation is normally considered between the hours of 07:00 and 23:00, with night time operation between 23:00 and 07:00. These times are taken in line with time periods and guidance defined by BS7445 and BS4142. The noise levels in Table 2 are representative of the minimum noise level measured in a 24-hour period, whose lowest levels are typically seen during the evening and night. 4.9 The following design criteria are considered applicable for cumulative mechanical noise levels 1m from the nearest residential premises, based on a complaint is unlikely criteria in accordance with BS4142. Achieving the rating assessment of complaint is unlikely depends on whether the noise source has distinguishable features as defined by Section 8.2 of the standard. Design Description BS4142:1997 Rating Assessment Noise Level LAeq,T db re. 20µPa P1 P2 Anonymous mechanical noises 10dB(A) below existing background Complaint is unlikely Distinguishable mechanical noises 15dB(A) below existing background Complaint is unlikely Table 3 Design noise levels for mechanical equipment at noise sensitive locations. ASSESSMENT OF BACKGROUND NOISE LEVELS 4.10 Ambient noise level data recorded in this assessment is representative of a sample of environmental conditions over the specified monitoring period. Seasonal variation should be expected with ambient noise adjacent to the site, where the area is dominated by water-flow noise and river flows typically change across the year. It is reasonable to predict therefore, that environmental noise levels may increase or decrease depending on the flow of water over Osney Lock and Weir The effect of changing environmental noise levels relative to river flow is difficult to quantify without extensive monitoring of different water levels, flow rates and lock configurations during different times of the year. No attempt has been made to quantify the change in ambient noise levels across seasonal variations where such detail is reasonably beyond the scope of this assessment The issue of varying environmental noise was discussed with the Environmental Health team of Oxford City Council during the noise assessment. It was verbally established that long term

11 ENVIRONMENTAL NOISE STUDY 8 noise monitoring would be unnecessary for an outline planning survey if some technical evaluation was provided on the river flow during noise assessment, against those which otherwise could be expected at different times of the year. Where the river flow rate during noise assessment can be shown as typical of the yearly average, then ambient noise levels may be considered proportionately so. Conversely, this exercise may highlight a need for further noise assessment at periods of significantly reduced river flow River flow data has been obtained and interpreted by Mannpower Consulting Limited for the period of ambient noise survey about Osney Lock and Weir. The following information is summarised from the data obtained: Water conditions were reasonably consistent from Tuesday 24 th to Wednesday 25 th July with flow rates around 25m 3 /s (25 th Q-percentile). Flow rates reduced on Thursday 26 th July to around 20m 3 /s (32 nd Q-percentile). Flow conditions during the survey period were marginally above the annual mean of 14m 3 /s (35 th Q-percentile). The setting of the lock gates was close to the average expected in July The noise level data shown graphically in Appendix D shows no indication of reduced noise levels during Thursday 26 th July even though a lower flow rate has been determined during this period. It is therefore logical to suggest that: Marginal changes in river flow (-5m 3 /s) above the average level have no measurable effect on the ambient noise level in the area. The noise level measurements are likely to be representative of the average river flow.

12 SOURCE NOISE STUDY 9 5 SOURCE NOISE STUDY 5.1 Further noise assessment was undertaken during the afternoon of Thursday 26 th July 2012 to establish noise levels of a similar hydropower development to that proposed at Osney. Noise measurements were taken at an existing Archimedean screw off Rosemary Lane, Bath BA2. This site was taken to be representative of the Osney development where it was of similar construction and electrical capacity. 5.2 The nature of noise from an Archimedean screw is complex in nature and consists of more than one noise component. These can be summarised as follows: A. Mechanical noise from the generator at the top of the screw. B. Blade-entry and water flow noise from the top of the screw. C. Water flow noise from the lower (out-water) end of the screw. D. Noise from water running through the fish pass. B A D C Figure 1 Identification of development noises using a similar site. 5.3 Those sources A to C are considered to be the most distinguishable or significant noises from the Archimedean screw that warrant specific noise assessment. No noise assessment is made on the installation of a fish pass at Osney where this element is representative of low-level water noise and wholly comparable to the natural environment. 5.4 The noise source [A] of the mechanical generator emits broadband noise and specific tonal component relative to the operational speed of the unit. Noise measurements of this source were made at 1m from the open housing, accounting for direct noise from the generator and reverberant noise from the enclosure. A level of 86dB(A) was noted at full-speed operation.

13 SOURCE NOISE STUDY Noise emanating from the top of the screw in [B] consists of broadband water flow noise and rhythmic blade-entry noise. The leading-edges of the screw are fitted with rubber fish bumpers to protect fish which may pass through the screw. As these fish bumpers enter the water they emit a cyclic plunging noise, relative to the number of screw blades and rotational speed of the screw. The phenomenon of blade-plunging noise is most noticeable at high speed operation (20-21rpm) where a specific component is audible at low frequency. Recent improvements in screw design have determined that low-frequency blade plunging noise in [B] can be designed out by angling the blade entry into the water. This design consideration should be adopted at Osney where it is to be installed in a residential area. 5.6 Noise measurements of [B] included some component of [A] where the generator housing was not fully insulating against noise from the generator. The housing contained ventilation apertures which allowed sound to pass directly from internal to external areas with minimal attenuation. A noise level of 79dB(A) at 2m was recorded but contains some component from the generator, particularly at 630Hz. 5.7 Out-water noise at [C] is produced as a result of turbulent water flow over the supporting lower section of the screw and blade-exits. This noise is typically broadband in nature but also contains some low-frequency content, subjectively less noticeable than at blade-entry [B]. A noise level of 81dB(A) at 1m was recorded with the screw at full speed operation. 1m from outwater 2m from screw top 1m from generator Sound Pressure Level db re. 20µPa Hz 31.5 Hz 40 Hz 50 Hz 63 Hz 80 Hz 100 Hz 125 Hz 160 Hz 200 Hz 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz 1 khz 1.25 khz 1.6 khz Third Octave Band Centre Frequency (Hz) 2 khz 2.5 khz 3.15 khz 4 khz 5 khz 6.3 khz 8 khz 10 khz Figure 2 Noise level measurements of a similar site. 5.8 The weather at the start of the noise survey was measured using a Kestrel 4500 weather station to be 30 C and 44% relative humidly, with a breeze averaging less than 0.5m/s. 5.9 The Larson Davis 824 sound level meter assembly as listed in Table 1 was used to determine the above noise levels over a nominal 1-2minute period at each point. Short term noise levels of 1-2 minutes were recorded given that the sources were constant in duration. The data measured in this section is considered applicable to long-term running noise that can be expected from the screw when operating at maximum speed.

14 SOURCE NOISE STUDY 11 PREDICTION OF NOISE FROM MECHANICAL PLANT (NOISE MODELLING) 5.10 The measured sound pressure level data in Figure 2 has been used to determine resulting noise levels 1m from nearest noise sensitive premises about Osney Lock and Weir. Third-octaveband sound pressure data has been used over the frequency range from 25Hz to 10kHz (as to cover octave bands from 31.5Hz to 8kHz) along with a scale model of the area extracted from land surveys and scheme proposals Mediterranean Acoustics Research & Development Ltd. Olive Tree Lab Terrain software V1.4.2 has been used to calculate the resulting noise level about the nearest noise sensitive premises. The modelling software is used to generate accurate results of sound pressure level with the following assumptions: The noise data in Figure 2 is used as input to the model, accounting for noise occurring at each part of the screw. Noise sources are taken to be omni-directional so no account is made for source directivity. Cumulative noise levels are considered from all three noise sources [A-C] at two receiver locations, assuming all noises are coherent. Noise from the generator and screw are initially considered separately to evaluate noise mitigation on each part of the development. Site geometry and layout is based on information obtained from topographical land surveys scheme design drawings. Surface attenuation factors are considered in line with the existing environment (i.e. water, gravel car park, grass). Receiver location is taken 1m from the façade of the nearest premises, 1.5m above the ground. Atmospheric absorption is based on ISO9613 Part 1, using meteorological conditions of 10 C and 70% relative humidity. Complex screening attenuation has been estimated from the noise model where line-ofsight may be partially restricted between proposed plant and nearest noise sensitive windows A recent paper 1 presented by the developers of Olive Tree Lab Terrain shows the benefits of using its software-based noise estimates, in comparison to measured results and common industry-adopted methods such as ISO The use of Terrain s complex calculation algorithms (based on purely scientific research) can be shown to produce very accurate diffraction and propagation estimates of noise. 1 P. Economou, P. Charalampous, A comparison of ISO and advanced calculation methods using Olive Tree Lab-Terrain, an outdoor sound propagation software application: predictions verses experimental results. Institute of Acoustics Vol 34. Pt

15 SOURCE NOISE STUDY Notwithstanding the accuracy of the software used, the success of any noise model is substantially dependent on the software user to generate valid and representative results. Reasonable care needs to be taken with the design of the model and ensuring that the topography is representative of the design proposals The noise level results presented in this section are considered to be an accurate account of the development noise level, based on measured input values and site topography. Two fundamental scenarios are considered in noise assessment, for different purposes of noise control, but considered cumulatively in noise impact assessment. These are listed as follows: 1) Contribution of screw noises [B + C] propagating to noise sensitive locations. 2) Estimation of generator noise [A] at nearest noise sensitive locations The results of part (1) will realistically determine the screw noise level at nearest receptor points. An appropriate sound insertion loss characteristic of the generator housing (being a selfcontained room of the development) will be determined separately in (2) where the modelled approach using Terrain cannot directly verify the amount of noise that travels through a building element, or from a contained room. Figure 3 Geometric noise modelling (ray tracing solution for screw noise at Bridge Street) The following estimates have been obtained from modelling screw noise about the proposed development at Osney Lock and Weir against the scheme design shown in Appendix C.

16 SOURCE NOISE STUDY 13 Octave Band Data db re. 20µPa Ref Description 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz Total (A) M1 M2 Screw noise No. 47 Bridge Street Screw noise The Boat House Table 4 Preliminary noise modelling results It is considered difficult to attenuate out-water noise in the direction of The Boat House where clear line-of-sight results from development to receiver position. The contribution of outwater noise is estimated to account for 54dB(A) at this receptor location, whose noise content should relate the existing (water noise dominated) environment From modelling the propagation of generator noise at Osney Weir, it can be shown that respective noise levels of 60dB(A) will result at No. 47 Bridge Street and 56dB(A) at The Boat House; if the unit is placed in a free-field environment. This scenario is substantially unrealistic knowing that the generator will be contained within a dedicated outbuilding; however one limitation of the chosen modelling approach is that it cannot determine noise breakout With knowledge of the resulting generator sound pressure level at the nearest receptor position, it can be shown that reducing generator noise (to below NR29) at No. 47 Bridge Street will typically result in achieving a cumulative noise level of 42dB(A). This process is used to specify a suitable sound reduction index of the generator building where the result falls in line with the design target noise levels listed in Table 3. Octave Band Data db re. 20µPa Ref Description 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz Total (A) M4 SRI - M3 X Generator noise (free-field) No. 47 Bridge Street Noise excess above NR29 Generator Building SRI Generator noise (attenuated) No. 47 Bridge Street Screw noise No. 47 Bridge Street Cumulative noise level No. 47 Bridge Street Table 5 Estimation of generator enclosure SRI and cumulative noise level at No. 47 Bridge Street The resulting level of attenuated generator noise at The Boat House is insignificant when compared to the level of screw (out-water) noise at this location.

17 SOURCE NOISE STUDY 14 Octave Band Data db re. 20µPa Ref Description 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz Total (A) M5 SRI - M2 Y Generator noise (free-field) The Boat House Generator Building SRI Taken from above Generator noise (attenuated) The Boat House Screw noise The Boat House Cumulative noise level The Boat House Table 6 Estimation of cumulative noise level at The Boat House Cumulative specific noise levels of 42dB(A) and 55dB(A) are used in noise assessment at the respective locations of No. 47 Bridge Street and The Boat House.

18 NOISE ASSESSMENT 15 6 NOISE ASSESSMENT 6.1 Cumulative noise levels from the proposed development have been assessed at the nearest noise sensitive locations of No. 47 Bridge Street and The Boat House. The difference between predicted BS4142 rating noise levels and lowest measured daytime L A90 background noise levels has been calculated to attain the BS4142 difference rating. 6.2 Rating penalties specified in Section 8.2 of BS4142 are considered as a precautionary measure with the proposed hydropower development; where resulting noise levels may contain lowfrequency or tonal components and be distinguishable from the surrounding environment. 6.3 The following noise assessment can be made for the proposed development: Receiver location Specific Noise Level db(a) Rating Penalty db BS4142:1997 Rating Level db(a) Lowest L A90, T Noise Level BS4142:1997 Rating Assessment No. 47 Bridge Street The Boat House 'Complaint is unlikely' 'Marginal significance' Complaint is likely Table 7 BS4142 assessment 1m from the nearest noise sensitive locations. 6.4 BS4142 states that where the rating level is 10dB below the measured background noise level then this a positive indication that complaints are unlikely. Use of the proposed scheme during a 24-hour period at Osney Lock and Weir is predicted to have a negligible impact on the neighbouring residences along Bridge Street with a -10dB rating assessment. 6.5 There is no description within BS41242 to describe a rating assessment of -6dB, as estimated at the commercial premise of The Boat House. A similarly low impact is expected occur at this location given the specific noise level is substantially below the lowest measured L A90 noise level. 6.6 Where specific noise levels are calculated 11-15dB below the existing background noise over a 24-hour period; it is predicted that the development will have no significant or measureable effect on the background noise level at the closest noise sensitive locations. 6.7 Quantification of the predicted noise level against the existing background noise level is an important step to demonstrate that the development will minimise background creep in the neighbouring area. This phenomenon only occurs if developments are permitted whereby the resultant noise level at the nearest noise sensitive location is close to or greater than the existing background noise. 6.8 Considering that an open window loss of 15dB will apply to the noise level inside the nearest neighbouring residential buildings of Bridge Street; a resultant internal noise level of 27dB L Aeq, T can be expected. Consulting noise level guidance in Section 3 of this assessment, anticipated

19 NOISE ASSESSMENT 16 noise levels will be within the WHO health limit of 30dB(A) for a bedroom. The specified scheme would therefore be unlikely to cause negative effects on sleep inside nearby residences. 6.9 A continuous equivalent noise level of 27dB L Aeq, T predicted inside nearby dwellings is unlikely to provoke a significant annoyance response from residences. Noise levels are significantly below the 35dB L Aeq, T critical health limit where moderate annoyance or speech interference may occur for a few people during the daytime and evening Resulting noise levels at the Boat House are unlikely to be excessive when referring to internal noise level guidance within BS8233:1999 Sound Insulation and Noise Reduction for Buildings Code of Practice. Assuming a reduction of 15dB reduction through an open window; an internal noise level of 40dB(A) will maintain reasonable conditions for study and work requiring concentration.

20 CONCLUSIONS 17 7 CONCLUSIONS 7.1 An assessment of background noise level has been carried out at a position representative of the nearest noise sensitive locations to Osney Lock and Weir. Ambient noise levels were recorded over a typical weekday period and are summarised in Table 2 and Appendix D of this assessment. 7.2 The ambient noise climate at the nearest receptor positions noise is recognised to be dominated by water flow from Osney lock and weir. From comparing the measured noise data against river flow conditions, the data obtained is likely representative of the average river flow despite being recorded in a period of flow marginally above the annual mean. No attempt has been made to quantify the change in ambient noise levels across all seasonal variations throughout the year where such detail is reasonably beyond the scope of this assessment. 7.3 The methodology and assessment criteria used within this report are contained in the British Standard 4142:1997 Rating industrial noise affecting mixed residential and industrial areas. Cumulative specific noise levels of 42-55dB(A) have been calculated at positions 1m away from the nearest noise sensitive windows, using noise modelling techniques of the proposed scheme. Calculation of specific noise level is detailed in Section 5 of this assessment. 7.4 BS4142 states that where the rating level is 10dB below the measured background noise level then this a positive indication that complaints are unlikely. Use of the proposed hydropower development during a 24-hour period at Osney Lock and Weir is predicted to have a negligible impact on the neighbouring residences along Bridge Street with a -10dB rating assessment. A similarly low impact is anticipated at the commercial premise of The Boat House with a -6dB rating assessment. 7.5 Where specific noise levels are calculated to lie significantly below the existing background noise over a 24-hour period; it is predicted that the development will have no significant or measureable effect on the background noise level at either noise sensitive location. 7.6 The determination of a suitably low noise level from the hydropower scheme depends on the form of the outbuilding to contain generator noise within its structure. The minimum sound reduction index (including all walls, apertures and ventilation) of the ventilation housing should exceed the following specification. Octave Band Data db re. 20µPa Ref Description 125 Hz 250 Hz 500 Hz 1 khz 2 khz 4 khz 8 khz SRI Minimum sound reduction index of generator housing (including ventilation) Table 8 Sound insulation requirement for generator housing. 7.7 It is also recommended that the design of the screw incorporates an improved blade-entry profile to minimise the low-frequency plunging effect which can occur at the top of the screw.

21 CONCLUSIONS With the inclusion of appropriate mitigation measures incorporated into the design of proposed outbuilding; noise should not be a detrimental issue for the hydropower scheme proposal at Osney Lock and Weir.

22 Appendix A: Glossary of Acoustic Terms I Appendix A: Glossary of Acoustic Terms DEFINITIONS AND UNITS A1.1 Noise is defined as unwanted sound. The range of audible sound is from 0dB to 140dB, which is taken to be the threshold of pain. The sound pressure detected by the human ear covers an extremely wide range. The decibel (db) is used to condense this range into a manageable scale by taking the logarithm of the ratio of the sound pressure and a reference sound pressure. A1.2 The unit of frequency is Hz. 1 Hz is one pressure fluctuation in one second. The frequency response of the ear is usually taken to be about 16Hz (number of oscillations per second) to 18,000Hz. The ear does not respond equally to different frequencies at the same level. It is more sensitive in the mid-frequency range than at the lower and higher frequencies, and because of this, the low and high frequency component of a sound are reduced in importance by applying a weighting (filtering) circuit to the noise measuring instrument. The weighting which is most used and which correlates best with the subjective response to noise is the db(a) weighting. This electronic filter matches the variation in the frequency sensitivity of the meter to that of the human ear. This is an internationally accepted standard for noise measurements. A1.3 The ear can just distinguish a difference in loudness between two noise sources when there is a 3dB(A) difference between them. Also when two sound sources of the same noise level are combined the resultant level is 3dB(A) higher than the single source. When two sounds differ by 10dB(A) one is said to be twice as loud as the other. A1.4 A few examples of noise of various levels are given below: Sound Level, db(a) Environmental Condition 0 10 Threshold of hearing Broadcasting studio Bedroom at night Library Living room urban area Typical business offices Conversation speech Average traffic on street corner Inside a factory Burglar alarm (1m away) Pneumatic drill (1m away) Jet aircraft take off Threshold of pain Table A1 Example noise levels. A1.5 The subjective response to a noise is dependent not only upon the sound pressure level and its frequency, but also its intermittency. Various statistical indices have been developed to

23 Appendix A: Glossary of Acoustic Terms II try and correlate annoyances with the noise level and its fluctuations in a changing noise environment. The indices and parameters used in this report are defined below: A1.6 L Aeq : Equivalent Continuous Sound Pressure Level The A-weighted sound pressure level of a steady sound that has, over a given period, the same energy as the fluctuating sound under investigation. It is in effect the energy average level over the specified measurement period (T) and is the most widely used indicator for environmental noise. A1.7 L AN : the A-weighted sound level exceeded for N% of the measurement period. In BS7445 the L A90 is used to define the background noise level, i.e. the noise that would remain once all local noise sources were removed. The L A10 gives an indication of the upper limit of fluctuating noise and is used in the assessment of road traffic noise. A1.8 L AMAX : The maximum A weighted noise level recorded during the measurement period.

24 Appendix B: Noise Measurement Locations III Appendix B: Noise Measurement Locations Site boundary Measurement location P1 P2 Figure B1 Background noise measurement locations.

25 Appendix B: Noise Measurement Locations IV Facing south at P1 No Bridge Street (noise sensitive locations) Facing south-west at P1 Figures B2 & B3 Background noise measurement location P1.

26 Appendix B: Noise Measurement Locations V Facing north at P2 Boat House (noise sensitive location) Facing east at P2 Figures B4 & B5 Background noise measurement location P2.

27 Appendix C: Scheme Design VI Appendix C: Scheme Design Figure C1 Scheme Design.

28 Appendix D: Noise Survey Summary VII Appendix D: 100 Noise Survey Summary Figure D1 - Background noise survey graphical data. Position 1: North of Osney Lock and Weir Sound Pressure Level db re.20µpa LAFmax LAFeq LAF90 LAFmin :00:00 13:00:00 14:00:00 15:00:00 16:00:00 17:00:00 18:00:00 19:00:00 20:00:00 21:00:00 22:00:00 23:00:00 00:00:00 01:00:00 02:00:00 03:00:00 04:00:00 05:00:00 06:00:00 07:00:00 08:00:00 09:00:00 10:00:00 11:00:00 12:00:00 13:00:00 14:00:00 15:00:00 16:00:00 17:00:00 18:00:00 19:00:00 20:00:00 21:00:00 22:00:00 23:00:00 00:00:00 01:00:00 02:00:00 03:00:00 04:00:00 05:00:00 06:00:00 07:00:00 08:00:00 09:00:00 Measurement Time HH:MM:SS

29 Appendix D: Noise Survey Summary VIII 100 Figure D2 - Background noise survey graphical data. Position 2: South of Osney Lock and Weir Sound Pressure Level db re.20µpa LAFmax LAFeq LAF90 LAFmin :00:00 13:00:00 14:00:00 15:00:00 16:00:00 17:00:00 18:00:00 19:00:00 20:00:00 21:00:00 22:00:00 23:00:00 00:00:00 01:00:00 02:00:00 03:00:00 04:00:00 05:00:00 06:00:00 07:00:00 08:00:00 09:00:00 10:00:00 11:00:00 12:00:00 13:00:00 14:00:00 15:00:00 16:00:00 17:00:00 18:00:00 19:00:00 20:00:00 21:00:00 22:00:00 23:00:00 00:00:00 01:00:00 02:00:00 03:00:00 04:00:00 05:00:00 06:00:00 07:00:00 08:00:00 09:00:00 Measurement Time HH:MM:SS

NOISE IMPACT ASSESSMENT 2016

NOISE IMPACT ASSESSMENT 2016 Panther Environmental Solutions Ltd, Unit 4, Innovation Centre, Institute of Technology, Green Road, Carlow, Ireland. Mobile: 087-8519284 Telephone /Fax: 059-9134222 Email: info@pantherwms.com Website:

More information

Pfizer Ireland Pharmaceuticals

Pfizer Ireland Pharmaceuticals Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,

More information

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown

More information

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare Environmental

More information

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE On behalf of: ITV plc Report No. 22396.01v1 October 2014 ITV CORONATION

More information

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01 Heslington East Campus Details of Noise Modelling and Noise Survey Report ref Heslington East Campus Details of Noise Modelling and Noise Survey January 2008 Arup Acoustics Admiral House, Rose Wharf, 78

More information

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA

More information

BASELINE NOISE MONITORING SURVEY

BASELINE NOISE MONITORING SURVEY t m s environment ltd TMS Environment Ltd 53 Broomhill Drive Tallaght Dublin 24 Phone: +353-1-4626710 Fax: +353-1-4626714 Web: www.tmsenv.ie BASELINE NOISE MONITORING SURVEY UNIVERSITY COLLEGE DUBLIN Report

More information

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA

More information

Bickerdike Allen Partners

Bickerdike Allen Partners 25 CHURCH ROAD, SE19 ENTERTAINMENT NOISE ASSESSMENT Report to Kayode Falebita Kingsway International Christian Centre 3 Hancock Road Bromley-By-Bow London E3 3DA A9540/R01-A-HT 26/07/2012 CONTENTS Page

More information

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary Sheringham Shoal Cawston, Norfolk Substation Noise Assessment Summary Document title: Substation Noise Assessment Summary Status: Final Date: 13 March 2015 Project name: Sheringham Shoal, Cawston, Norfolk

More information

Offaly County Council

Offaly County Council Derryclure Landfill Facility, Derryclure, Co. Offaly Annual Monitoring Report Waste Licence Reg. No. W0029-04 Report Date: th October 15 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth

More information

Xtratherm Limited Kells Road, Navan, Co Meath

Xtratherm Limited Kells Road, Navan, Co Meath Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre Ennis Road Limerick Kells Road, Navan, Co Meath Annual Environmental Noise Survey 2017 IPPC Licence

More information

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE Head Office Postal Address T 02 9908 1270 Suite 9 PO Box 270 F 02 9908 1271 38-46 Albany St Neutral Bay 2089 E info@acousticdynamics.com.au St Leonards 2065 ABN: 36 105 797 715 W www.acousticdynamics.com.au

More information

McGill Environmental Ltd.

McGill Environmental Ltd. McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan

More information

Acoustics Technical Note

Acoustics Technical Note Acoustics Technical Note To Ian Roach From Alf Maneylaws Copies to File Date 30/3/11 Subject D123356: Devonport EfW: Analysis of measurement data to support adopted approach to BS4142 assessment. Introduction

More information

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times 765 kv Substation Acoustic Noise Impact Study by Predictive Software and

More information

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick. info@axisenv.ie 00353 61 324587 Unit 4, Osberstown Industrial Park, Caragh

More information

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Date: 09 March 2016 REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Client: Edinburgh Limited Report Author:... Dr R. Peters Principal Consultant

More information

Noise Assessment for Planning Purposes - as per TAN11

Noise Assessment for Planning Purposes - as per TAN11 Noise Assessment for Planning Purposes - as per TAN11 Report No: 1703035R01A Report Status: Final Report (Amended) Dated: 23 October 2017 Purchase order No: n/a Prepared for: Garep Demirci 73 Spencer David

More information

Roche Ireland Limited

Roche Ireland Limited Limited Clarecastle, Co. Clare Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 1 st February 17 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth Report No.

More information

Methods for rating and assessing industrial and commercial sound

Methods for rating and assessing industrial and commercial sound BS 4142:2014 BSI Standards Publication Methods for rating and assessing industrial and commercial sound BS 4142:2014 BRITISH STANDARD Publishing and copyright information The BSI copyright notice displayed

More information

Appendix N. Preliminary Noise Assessment Technical Memorandum

Appendix N. Preliminary Noise Assessment Technical Memorandum Appendix N Preliminary Noise Assessment Technical Memorandum SENES Consultants Limited MEMORANDUM 121 Granton Drive, Unit 12 Richmond Hill, Ontario Canada L4B 3N4 Tel: (905) 764-9380 Fax: (905) 764-9386

More information

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental.

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental. ANNUAL MONITORING OF ENVIRONMENTAL NOISE AT THE BORD NA MóNA KILBERRY COMPOST FACILITY IN COMPLIANCE WITH IED LICENCE, NO. W0198-01 For the Attention of: Site Work & Report Prepared by: Anua File Ref:

More information

Environmental Noise Assessment Cambourne to Cambridge options

Environmental Noise Assessment Cambourne to Cambridge options Environmental Noise Assessment Cambourne to Cambridge options CLIENT: Cambridgeshire County Council Major Infrastructure Delivery Box No SH1311 Shire Hall Cambridge CB3 0AP CONTACT: Tim Watkins REPORTED

More information

Roche Ireland Limited

Roche Ireland Limited Roche Ireland Limited Clarecastle, Co. Clare Environmental Noise Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 6 th October 17 Fitz Scientific Unit 35A, Boyne Business Park,

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 1 November 2018 Ref: 171356/8121 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: OCTOBER 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise

More information

January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4

January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4 January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4 MALONE O REGAN 2B Richview Office Park, Clonskeagh, Dublin 14. Tel:

More information

SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011

SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011 Date: 24 June 2012 Ref: 00148/Felbridge/002/rp SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 16 May 2018 Ref: 171356/7853 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: MAY 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise compliance

More information

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:

More information

SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011

SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011 Date: 9 June 2012 Ref: SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by

More information

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring October 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring October 2017 Reference: Report date:

More information

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Appendix 8. Draft Post Construction Noise Monitoring Protocol Appendix 8 Draft Post Construction Noise Monitoring Protocol DRAFT CPV Valley Energy Center Prepared for: CPV Valley, LLC 50 Braintree Hill Office Park, Suite 300 Braintree, Massachusetts 02184 Prepared

More information

REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012

REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012 Date: 25 July 2013 Ref: REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H.

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 15 December 2017 Suite 6, Level 1, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Appendix G Noise and Vibration Assessment

Appendix G Noise and Vibration Assessment Appendix G Noise and Vibration Assessment Annex G1: Noise Perception and Terminology Annex G2: Baseline Noise Monitoring Annex G3: Construction Information Annex G4: Operational Information Annex G1: Noise

More information

Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver. Vancouver Airport Authority

Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver. Vancouver Airport Authority Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver Vancouver Airport Authority September 27, 2016 Table of Contents INTRODUCTION... 2 OBJECTIVES... 2 VANCOUVER: AIRCRAFT

More information

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Appendix G Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Environmental Management Plan G May 2014 Colton Coal Mine Aldershot, Queensland Review of Baseline Noise Monitoring

More information

Noise Mitigation Study Pilot Program Summary Report Contract No

Noise Mitigation Study Pilot Program Summary Report Contract No Ohio Turnpike Commission Noise Mitigation Study Pilot Program Summary Report Contract No. 71-08-02 Prepared For: Ohio Turnpike Commission 682 Prospect Street Berea, Ohio 44017 Prepared By: November 2009

More information

WITHIN GENERATOR APPLICATIONS

WITHIN GENERATOR APPLICATIONS POWER SYSTEMS TOPICS 9 Measuring and Understanding Sound WITHIN GENERATOR APPLICATIONS INTRODUCTION When selecting a generator, there are many factors to consider so as not to negatively impact the existing

More information

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE Cedric Roberts Environmental Operations, Integrated Assessment, Queensland Environmental Protection Agency, 160 Ann Street, Brisbane, Queensland,

More information

APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS

APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS PORT OF NAPIER WHARF 6 FUTURE PORT NOISE MAPS (2026) Rp 004 r02 2015784A 20 September 2016 84 Symonds Street PO Box 5811 Wellesley Street Auckland

More information

Appendix D: Preliminary Noise Evaluation

Appendix D: Preliminary Noise Evaluation Appendix D: Preliminary Noise Evaluation Acoustics The study of sound and its properties is known as acoustics. By considering basic physical properties of sound and the acoustic environment, the potential

More information

Further Investigations of Low-frequency Noise Problem Generated by Freight Trains

Further Investigations of Low-frequency Noise Problem Generated by Freight Trains Proceedings of Acoustics 2012 - Fremantle Further Investigations of Low-frequency Noise Problem Generated by Freight Trains Jingnan Guo, John Macpherson and Peter Popoff-Asotoff Noise Regulation Branch,

More information

Attended Noise Monitoring - Quarter Ending September 2013

Attended Noise Monitoring - Quarter Ending September 2013 Unity Mining Level 10, 350 Collins St Melbourne VIC 3000 Version: Page 2 PREPARED BY: ABN 29 001 584 612 Units 7-8, 26-28 Napier Close Deakin ACT 2600 Australia (PO Box 9344 Deakin ACT 2600 Australia)

More information

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 OneSteel Recycling Pty Ltd 14-Jul-2017 60493017 OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 Testing

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015

More information

A REPORT OF MONITORING OF AIRCRAFT NOISE FROM STANSTED AIRPORT AT HELIONS BUMPSTEAD, ESSEX BETWEEN SEPTEMBER AND DECEMBER 2008

A REPORT OF MONITORING OF AIRCRAFT NOISE FROM STANSTED AIRPORT AT HELIONS BUMPSTEAD, ESSEX BETWEEN SEPTEMBER AND DECEMBER 2008 Date: 6 November 2009 Our ref: 09296/001/rp A REPORT OF MONITORING OF AIRCRAFT NOISE FROM STANSTED AIRPORT AT HELIONS BUMPSTEAD, ESSEX BETWEEN SEPTEMBER AND DECEMBER 2008 carried out by R J Peters Employer:

More information

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia ICSV14 Cairns Australia 9-12 July, 2007 ACOUSTIC BARRIER FOR TRANSFORMER NOISE Ruisen Ming SVT Engineering Consultants, Leederville, WA 6007, Australia Roy.Ming@svt.com.au Abstract In this paper, an acoustic

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 20 June 2017 Doc no. 102-QM-RP-4-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:

More information

Please refer to the figure on the following page which shows the relationship between sound fields.

Please refer to the figure on the following page which shows the relationship between sound fields. Defining Sound s Near The near field is the region close to a sound source usually defined as ¼ of the longest wave-length of the source. Near field noise levels are characterized by drastic fluctuations

More information

REPORT PERIOD: JANUARY 01 MARCH

REPORT PERIOD: JANUARY 01 MARCH QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT PERIOD: JANUARY 01 MARCH 31 2018 IE LICENCE REF. NO. W0178-02 APRIL 2018 QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT

More information

AMERICAN UNIVERSITY EAST CAMPUS DEVELOPMENT WASHINGTON, D.C. Environmental Noise Study. Project Number

AMERICAN UNIVERSITY EAST CAMPUS DEVELOPMENT WASHINGTON, D.C. Environmental Noise Study. Project Number AMERICAN UNIVERSITY EAST CAMPUS DEVELOPMENT WASHINGTON, D.C. Environmental Noise Study Project Number 11-107 Douglas P. Koehn, M.S. Senior Consultant 12040 SOUTH LAKES DRIVE, SUITE 104, RESTON, VIRGINIA

More information

Pipeline Blowdown Noise Levels

Pipeline Blowdown Noise Levels Pipeline Blowdown Noise Levels James Boland 1, Henrik Malker 2, Benjamin Hinze 3 1 SLR Consulting, Acoustics and Vibration, Brisbane, Australia 2 Atkins Global, Acoustics, London, United Kingdom 3 SLR

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date November 2014 Issue No 1 TABLE OF CONTENTS 1. Introduction/Purpose 2. Responsibility and Authority 3. Noise Monitoring 4.

More information

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July

More information

City and Borough of Juneau

City and Borough of Juneau City and Borough of Juneau Flightseeing Noise Measurement and Assessment Study Proposed Work Plan BACKGROUND AND STUDY OBJECTIVES The objective of the flightseeing noise measurement program is to provide

More information

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S Pre-Construction Sound Study Substation DRAFT January 2011 D A T A AN AL Y S IS S OL U T I ON S TABLE OF CONTENTS 1.0 INTRODUCTION...1 2.0 SOUND LEVEL MONITORING...1 3.0 SOUND MODELING...4 3.1 Modeling

More information

CHAPTER 3 NOISE FUNDAMENTALS

CHAPTER 3 NOISE FUNDAMENTALS CHAPTER 3 NOISE FUNDAMENTALS While a great deal is known about aircraft noise, the methods used to calculate noise exposure can be difficult to understand. Determining aircraft noise impacts involves logarithmic

More information

REPORT OF NOISE MONITORING AT HEVER FEBRUARY 2011 TO JANUARY 2012

REPORT OF NOISE MONITORING AT HEVER FEBRUARY 2011 TO JANUARY 2012 Date: 25 June 2012 Ref: REPORT OF NOISE MONITORING AT HEVER FEBRUARY 2011 TO JANUARY 2012 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H. Holdich

More information

REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012

REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012 Date: 25 July 2013 Ref: REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H. Holdich

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 10 October 2017 Suite 6, Level 1,, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:

More information

Low frequency noise near wind farms and in other environments

Low frequency noise near wind farms and in other environments www.epa.sa.gov.au www.resonateacoustics.com Low frequency noise near wind farms and in other environments Low frequency noise near wind farms and in other environments Page i Low frequency noise near wind

More information

ENVIRONMENTAL NOISE ASSESSMENT

ENVIRONMENTAL NOISE ASSESSMENT ENVIRONMENTAL NOISE ASSESSMENT AT MURPHY BREWERY. Report Dated: 25 June 15 Greenhills House, Kilmoney, Carrigaline, Co. Cork. Tel: 353 21 437433 http://www.env.ie/ TITLE: Environmental Noise Assessment

More information

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1 Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC Final Report Rev 1 Noise Impact Assessment RWDI # 1502274 SUBMITTED TO Paul Dufault Project Manager Metro Vancouver 4330

More information

Environmental Noise Propagation

Environmental Noise Propagation Environmental Noise Propagation How loud is a 1-ton truck? That depends very much on how far away you are, and whether you are in front of a barrier or behind it. Many other factors affect the noise level,

More information

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices ABERDEEN HARBOUR EXPANSION PROJECT November 2015 Volume 3: Technical Appendices Appendix 20-B BASELINE NOISE SURVEY 20-B BASELINE NOISE SURVEY Noise Sensitive Receptors A desk-based study and site walkover

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report

More information

NOISE IMPACT STUDY. Benton Boarding and Daycare 5673 Fourth Line Road Ottawa, Ontario City of Ottawa File No. D

NOISE IMPACT STUDY. Benton Boarding and Daycare 5673 Fourth Line Road Ottawa, Ontario City of Ottawa File No. D NOISE IMPACT STUDY Benton Boarding and Daycare 5673 Fourth Line Road Ottawa, Ontario City of Ottawa File No. D07-12-13-0024 Page 2 of 23 TABLE OF CONTENTS 1.0 INTRODUCTION / BACKGROUND INFORMATION...6

More information

Memorandum 1.0 Highway Traffic Noise

Memorandum 1.0 Highway Traffic Noise Memorandum Date: September 18, 2009 To: Chris Hiniker, SEH From: Stephen B. Platisha, P.E. Re: Updated CSAH 14 Noise Analysis The purpose of this memorandum is to provide the results of the revised traffic

More information

Assured Monitoring Group

Assured Monitoring Group Assured Monitoring Group YARRANLEA SOLAR FARM NOISE & VIBRATION IMPACT ASSESSMENT JANUARY 2017 I3 CONSULTING PTY LTD Project ID. 10734 R_1 DATE OF RELEASE: 15/02/2017 Table 1: Document approval Name Position

More information

Defence Infrastructure Organisation RAF Brize Norton

Defence Infrastructure Organisation RAF Brize Norton Defence Infrastructure Organisation RAF Brize Norton C130 EGR Noise Assessment Technical Report AMEC Environment & Infrastructure UK Limited Document Revisions No. Details Date 1 Draft Report 12343i1

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 11 August 16 Doc no. 102-QM-RP-1-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Problems with the INM: Part 2 Atmospheric Attenuation

Problems with the INM: Part 2 Atmospheric Attenuation Proceedings of ACOUSTICS 2006 20-22 November 2006, Christchurch, New Zealand Problems with the INM: Part 2 Atmospheric Attenuation Steven Cooper, John Maung The Acoustic Group, Sydney, Australia ABSTRACT

More information

Bancroft & Piedmont Cellular Facility

Bancroft & Piedmont Cellular Facility Page 1 of 19 Environmental Noise Analysis Bancroft & Piedmont Cellular Facility Berkeley, California BAC Job # 2015-177 Prepared For: Complete Wireless Consulting Attn: Ms. Kim Le 2009 V Street Sacramento,

More information

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation INTERNATIONAL STANDARD IS0 9613-2 First edition 1996-I 2-l 5 Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation Acoustique -Attenuation du son lors de

More information

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 REPORT 30-1664R1R0 Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 PREPARED FOR P.O Box 806 Cessnock NSW 2325 14 MAY 2007 Quarterly Noise Monitoring Report Austar

More information

REVISED NOISE IMPACT STUDY

REVISED NOISE IMPACT STUDY REVISED NOISE IMPACT STUDY Benton Boarding and Daycare 5673 Fourth Line Road Ottawa, Ontario City of Ottawa File No. D07-12-13-0024 Integral DX Engineering Ltd. Page 2 of 24 TABLE OF CONTENTS 1.0 INTRODUCTION

More information

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W0115-01 Report Date: 09 th July 2013 Report Number: 3220-13-03 Version 0 AXIS environmental services 40 Coolraine

More information

Noise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare

Noise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare Bray (Co. Wicklow) 01 276 1428 Lisburn (Co. Antrim) 028 9262 6733 Birmingham (U.K.) 0121 673 1804 Blackrock (Co.Cork) 021 4536155 Noise Monitoring Report 2017 For Schloetter (Ireland) Ltd. Naas Enterprise

More information

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

Template Planning Condition on Amplitude Modulation Noise Guidance Notes www.renewableuk.com Template Planning Condition on Amplitude Modulation Noise Guidance Notes December 2013 Template Planning Condition on Amplitude Noise Guidance Notes Modulation Introduction Introduction

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date 31/7/15 Issue No 2e DRAFT TABLE OF CONTENTS 1. Policy Statement 2. Introduction/Purpose 3. Responsibility and Authority

More information

Assessing the accuracy of directional real-time noise monitoring systems

Assessing the accuracy of directional real-time noise monitoring systems Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Assessing the accuracy of directional real-time noise monitoring systems Jesse Tribby 1 1 Global Acoustics Pty Ltd, Thornton, NSW,

More information

Fundamentals of Environmental Noise Monitoring CENAC

Fundamentals of Environmental Noise Monitoring CENAC Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative

More information

Statement of Evidence of N I Hegley

Statement of Evidence of N I Hegley IN THE MATTER AND IN THE MATTER of the Resource Management Act 1991 of Notices of Requirement to enable the construction, operation and maintenance of the City Rail Link. Statement of Evidence of N I Hegley

More information

Sound Reflection from a Motorway Barrier

Sound Reflection from a Motorway Barrier Auckland Christchurch Kuala Lumpur Melbourne Sydney Wellington www.marshallday.com Sound Reflection from a Motorway Barrier Christopher W Day Paper revised June 2005 chrisday@marshallday.co.nz Abstract

More information

REPORT OF NOISE MONITORING AT DOMEWOOD DECEMBER 2012 TO DECEMBER 2013

REPORT OF NOISE MONITORING AT DOMEWOOD DECEMBER 2012 TO DECEMBER 2013 Date: 07 April 2014 Ref: REPORT OF NOISE MONITORING AT DOMEWOOD DECEMBER 2012 TO DECEMBER 2013 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H.

More information

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring August 2018 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring August 2018 Reference: Report date:

More information

Noise and Ground-Borne Vibration Monitoring

Noise and Ground-Borne Vibration Monitoring 69 Noise and Vibration Study Noise and Ground-Borne Vibration Monitoring Labrador City, Newfoundland Nov, 07 Iron Ore Company of Canada TABLE OF CONTENTS 1.0 INTRODUCTION... 2 1.1 Study Objectives... 2

More information

SILVERSTONE CIRCUIT MASTERPLAN APPENDIX H NOISE & VIBRATION

SILVERSTONE CIRCUIT MASTERPLAN APPENDIX H NOISE & VIBRATION ... a world-class motor sport destination and leading business, education, leisure and entertainment venue with a brand that is synonymous with excellence and innovation SILVERSTONE CIRCUIT MASTERPLAN

More information

91 Street Earth Berm Removal in Edmonton, Alberta

91 Street Earth Berm Removal in Edmonton, Alberta aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Monitoring For The 91 Street Earth Berm Removal in Edmonton,

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 1996-2 Second edition 2007-03-15 Acoustics Description, measurement and assessment of environmental noise Part 2: Determination of environmental noise levels Acoustique Description,

More information

HIIUMAA OFFSHORE WINDFARM, ESTONIA LOW FREQUENCY NOISE AND INFRASOUND SURVEY

HIIUMAA OFFSHORE WINDFARM, ESTONIA LOW FREQUENCY NOISE AND INFRASOUND SURVEY Intended for Nelja Energia AS Document type Report Date 15/11/2016 Reference 1510023010 Madalsagedusliku ning infraheli uuringu tõlge asub KMH aruande ptk-s 5.11.2 Infraheli ja madalsageduslik müra HIIUMAA

More information

Non-Technical Summary of Environmental Statement

Non-Technical Summary of Environmental Statement Non-Technical Summary of Environmental Statement Speedway World Cup Introduction This document is the Non-Technical Summary (NTS) of the Environmental Statement (ES) prepared for the proposed Speedway

More information

Orora Compliance Monitoring

Orora Compliance Monitoring Orora Compliance Monitoring ORORA LIMITED April 2016 Noise Monitoring 038900_20160506 A 6 May 2016 Orora Compliance Monitoring Project no: Document title: IA038900 April 2016 Noise Monitoring Document

More information

UC Berkeley Northside Relocation Cellular Facility

UC Berkeley Northside Relocation Cellular Facility Page 1 of 19 Environmental Noise Analysis UC Berkeley Northside Relocation Cellular Facility Berkeley, California BAC Job # 2015-290 Prepared For: Complete Wireless Consulting Attn: Kim Le 2009 V Street

More information