Alarm-Display SD 9648
|
|
- Millicent Scarlett Rich
- 6 years ago
- Views:
Transcription
1 Alarm-Display SD Digital- or 1 Digital- and 8 Analog inputs Features M Activation with voltage free contacts, 0/4 V signals or 0/ ma for monitoring of analog measuring values M First- or last message, priority M Internal and external reset M LCD-text display with background lighting lines, 16 characters each, 6.5 mm high M Text length max. 64 characters M Programming by frontside keypad M Acoustic alarm with integr. buzzer M Alarm relay, SPDT M Real-time clock M Front protection IP65 General The Alarm-Display SD9648 will be used for indicating and evaluations of alarm signals as well as analog measured values. Short information Sort mode The messages take place alternatively after their priority or after its occurrence (first/last message). Display mode Fault signals are cyclically or permanently displayed. With permanent announcement all messages can be queried by depressing the key. Display time It is programmable whether a message is deleted automatically after omission of the cause or additionally an acknowledgement is necessary. Relay / buzzer Parallel to the messages buzzers and/or alarm relay can be activated. Start-up-delay After switching on of the device, for an adjustable time by s all alarm signals are suppressed. Message delay time Programmable from s. Analog input Display range, alarm setpoints und alarm performance (min / max) are free programmable. Process values can be displayed at any place in the message. Date / time Can inserted in arbitrary place into a message (only with real-time clock), alternatively the current time or the time with the occurrence of an alarm. Note: With powerless device the inputs became a high resistance
2 Content Page Technical data... Connection diagram...3 Dimensions...3 Controls and indicators...4 Description...4 Programming...5 Error messages...1 Characters...13 Variables Programming examples...14 Ordering code...16 Start-up note: Before the device can be used, it must be configurated for the intended use. Technical data Power supply Supply voltage : 30V AC ±10%, 115V AC ±10%, 4V AC±10%, 4V DC ±15% Frequence AC : 50/60 Hz Power consumption : max. 3.5 VA Operating temperature : C Rated voltage : 50 V~ acc. to VDE 0110 between input/output/supply voltage degree of pollution, overvoltage categoric III Test voltage : 4kV=, between input/output/supply voltage - conformity : EN550, EN60555, IEC /4/5/11/13 Inputs Digital inputs Impulse/ break Analog inputs Accuracy Temperature coefficient Transmitter-supply : 0/4 V DC, Ri = 10 kω, switching threshold low <4 V, High >11 V max. 35 V : min. 10 ms : 0/ ma, Ri = 100 Ω voltage drop max.. V at 0 ma overload app. 3 ma (max. voltage 35 V). With powerless device the inputs became a high resistance : 0.1 %, ± 1 Digit : < %/K : Uo = 4 V, Ri 150 Ω, max. 50 ma Display : LCD-text display white/blue, 6.5 mm high with background lighting Display range : lines 16 characters each Refreshing time : 0.5s Output Panel case Dimensions Weight Connection Protection : SPDT < 50 V AC < 50 VA < A, < 300 V DC < 50 W < A : DIN 96x48 mm, Material PA6-GF; UL94V-0 : Front 96x48 mm, mounting depth 100 mm, : max. 390 g : Clamp terminals, mm² single wire, 1,5 mm² flexible wire, AWG14 : Front IP65, terminals IP0, finger safe acc. to German BGV A3 - -
3 Connection diagram Digital- or analog inputs 1-8 Digital inputs 9-0 Input 1 Input Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 1 Input 13 Input 14 Input 15 Input 16 Input 17 Input 18 Input 19 Input 0 Extern. acknowledge +4 V DC GND Alarm relay Operation with voltagefree NO contact Supply voltage Operation with voltagefree NC contact Opeartion with external control voltage 4 V DC Analog inputs 0/ ma Note! If the analog signal is generated by an device with automatic burden recognition (current/voltage changeover), the analog output must be configured to mA (see page 7). Dimensions Seal Terminal position Panel cut-out acc. to DIN x48-3 -
4 GHM-Messtechnik GmbH Standort Martens Controls and indicators Field for additional text Infrared-sensor Up button Right button Left button Enter/acknowledge button Down button Description After switching on the supply the device initializes itself. The display shows the message SD9648 VX.X (X.X software-version). After the initializing procedure the device is located in the working level. Displayed messages can be paged and acknowledged with button. Pressing the button for more than seconds, activates the Configuration level Now all the parameters defining the function of the SD9648 can be programmed. After finishing the configuration or when no button was pushed for more than minutes, the program returns to the working level. Leaving the configuration level is possible at any time by pressing the button for more than seconds. Programming: Menu selection With every new display page menu points will be shown. The arrow º marks the actual menu point With button the next menu point will be selected With button the last menu point will be selected (Over the infrared remote control IR51 the menu items can also be selected by entering of the first letters.) With button the wanted menu will be called up. Parameter (e.g. input-no.; measuring range, alarm setpoint...) The wanted value will be entered with and. Arrows º» indicates that more than 3 characters can be displayed in the arrow direction. + = 1 parameter back Messages The wanted character position in the message will be selected with buttons and. The wanted character will be selected with buttons and. The entered character will be automatically stored with button and the cursor shows the next position. Special functions: + = Deletes character at the cursor position. Repeat function by pressing the button continuously. + = Blank 8 at the actual cursor position. Repeat function by pressing the button continuously. + = Line feed in the next line of the character set (see page 13). + = Simulation for controlling of the edited messages including the variables (see page 13)
5 Programming Notes to representation Parameter is only displayed when configurated Parameter is only displayed when feature is included (see order code) Note: All parameters can be called if they are not blocked by other programmed parameters and if they are available. Factory settings are shown in the display grafic. Menue display Operating level SD9648 StörmeldeDisplay press s min. Parameter display When first calling the configuration level. 1 Configuration level ºLanguage Standard text 1.1 deutsch ~ englisch Language of the operating instructions. Language ºStandard text.1 SD9648 StörmeldeDisplay Message if no error is present. Edit message, see page 4 and 13. continue page 6-5 -
6 GHM-Messtechnik GmbH Standort Martens Menue display Parameter display 3 ºMessages Copy messages Message programming for the inputs Devices with analog inputs have additional parameters. 3.1 Input: 1 (digital) Selection of input no. (depends on device type) 3. Input: 1 Selection of input no. (analog) 3.3 Measure range 1 Decimals: 1 Decimal selection, decimals 3.4 Measure range 1 Start: 0.0 Setting possible from digit Note! In case of change of a measuring range including analog variables in the message they must be adapted if necessary (see page 13). 3.5 Measure range 1 End: 100,0 3.6 Alarm function 1 OFF ~MIN ~MAX Selection possible from digit Switching performance for alarm output activation 3.7 Alarm 1 at: 0.0 Setting possible from start value... end value 3.8 Text 1 Edit message (see page 4 and 13). Note : Parameter programmning for input -0 are identical continue page 7-6 -
7 Menue display Parameter display 4 Messages ºCopy messages Copy mode. With same or similar messages the programming expenditure can be reduced with this function. 4.1 Copy message from 1 to Start- and destination address (identical with input no.). Note: With same start- and destination address the existing text will be deleted and with Text X substituted. X = Input-no. 4. Overwrite? Message N Only displayed if text is available at the destination address. Selection with Y or N. 4.3 Text 1 Edit message 5 ºInput type Alarm output Input identification. NO (H) or NC (L) with digital inputs and 0...0mA or 4...0mA with analog inputs 5.1 Input 1 3 º active H H H Enter H or L for digital inputs Input 1 3 º 0/4mA Enter 0 or 4 for analog inputs Input º active H H H Enter H or L for digital inputs continue page 8-7 -
8 GHM-Messtechnik GmbH Standort Martens Menue display Parameter display 6 Input type ºAlarm output Definition of the criteria for the identification of messages when simultaneous several alarms being present. 6.1 Text scrolling after 1s Input of the display time of a message of several lines (scrolling lines 1+/3+4) and/or change to other activated messages. 6. Auto scrolling OFF ~ON Automatical scrolling between several presented messages. Selection of ON jumps back to the menu selection. 6.3 Sort by First message Selection: First message The first message is permanently indicated. When manual scrolling is selected, every following messages are displayed in the queue of there indicated sequence Last message as before, however in reverse order. Priority The message with the highest priority is permanently indicated. At manual scrolling all further messages in the order of their priority, and/or with the same priority are sorted according to the last message mode. 6.4 Input 1 º Priority 1 1 Enter wanted priority. 1 = highest priority 9 = lowest priority continue page 9-8 -
9 Menue display Parameter display 7 ºAcknowledge Alarm relay Acknowledge function extern and/or intern possible 7.1 Acknowledge int. ~OFF ON Acknowledge intern with button. Note: only the just displayed and inactive message will be deleted. The internal buzzer can always be reset with every frontside button. 7. Acknowledge ext. ~OFF HIGH ~LOW 7.3 Quit relay Fault removed Acknowledge extern Selection OFF HIGH (NO) LOW (NC) Note: all inactive messages will be deleted Fault removed The relay can be quit if the belonging message is not present (like the message in the display). Fault pending The relay can be quit if the belonging message is present (like buzzer). 7.4 Input 1 3º Acknowl. N N N Selection Y activates the general acknowledge function for each input. 8 Acknowledge ºAlarm relay Switching function of the internal alarm relay. 8.1 Not energized ~Energized Switching performance Not energized Relay active at alarm Energized Relay inactive at alarm 8. Inputs 1 3º Relay N N N Selection Y activates the alarm relay for the indicated input continue page
10 GHM-Messtechnik GmbH Standort Martens Menue display Parameter display 9 ºBuzzer Alarm delay Buzzer function 9.1 Input 1 3º Buzzer N N N Selection Y activates the buzzer for the indicated input. The buzzer can quit with every frontside button 10 Buzzer ºAlarm delay Alarm delay function 10.1 Startup delay Delay 0s Startup delay of the device after power on from s. 10. Messages delay 0.0s Message delay after incoming alarm from s. 11 ºDate/time LCD-display Only with feature realtime clock 11.1 Date tt.mm.jjjj XX.XX.XXXX Configuration of the actual date. 11. Time hh:mm:ss XX:XX:XX Configuration of the actual time. continue page
11 Menue display Parameter display 1 Date/time ºLCD-display 1.1 Brightness Level: 7 Configuration of display brightness from Contrast Level: 5 Configuration of display contrast from ºRemote control Input lock 13.1 Device adress No: 7 Input of a device address within the range Itś possible to program 99 devices with the remote control IR51 without mutual influence. If the address 1 should be standard, the address no must not be changed by IR51. Every device react of each pressed button. 14 Remote control ºInput lock 14.1 Input lock OFF ~INT ~ALL INT Front key pad locked ALL as before, additional remote control is locked. Changing possible by pressing buttons or for seconds. continue page
12 GHM-Messtechnik GmbH Standort Martens Menue display Parameter display 15 ºFactory adjust (Exit) 15.1 Factory adjust Code=0 Code for factory settings. 16 Factory adjust º(Exit) End of programming Operating level SD9648 StörmeldeDisplay If no alarm is indicated the programmed Standard text (page 5) will be displayed. Error messages Parameter error -> please check If this messages appears, an configuration error is present. This message will be deleted by entering the Configuration level. The device is working with factory settings of this / these parameter(s). The function must be tested. If the same messages appears again, the device must be sent for factory repair. Write protected!! Input lock activated. See page
13 Character set: 8 = Blank A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z ä ö ü ß ñ ² ³ -1 $ - + ± * ^ [ ] ( ) < = >» ~ % # & α γ μ Ω π Σ / 8!? : ;,. _ 8 = 1 character forwards = 1 character backwards + = Line feed to the next line of the character set Variable Variable can inserted in arbitrary place into a message. Variable Function $c Number of the indicated message ( = input number) $a Number of indicated messages $o Priority of the indicated message (does not work at Standard text ) $n Recording counter of repeated messages on one input until acknowledge appears. (f 1Hz; nmax=99; if no. >99 flashes) [xxxx] All characters between [ ] are flashing (no combination with analog values possible) Only with feature real-time clock $h Actual hour (4h mode) $i Actual hour (1h mode) $p am / pm (1h mode) $m Actual minute $s Actual second $d Actual day $x Actual month $y Actual year $w Actual week day, letters identification εh, εi, εp, εm, εs, εd, εx, εy, εw as before, if messages appears (does not work at Standard text ) εt Additional time 1/100 seconds Only with feature analog inputs $1... $8 Shows permanent the analog value of the actual inputs By pressing the button after entering the input number, a number of substitute symbols is inserted automatically of the confirured measuring range into the text. This preemption can be adapted if necessary to the requirements. _ is a substitute symbol for a number. "," or "." indicates the decimal point. Maximally 5 numbers can be indicated, whereby already the variable name reserves $x already numbers and/or signs and 1 number. If the difference between measuring range end and measuring range start is more than 10000, the last number is kept automatically to "0". If are less digits reserved than necessary for the measuring range, this is marked in the simulation mode (buttons + at the same time) by flashing squares. ε1... ε8 Shows the analog value at input to the actual time of the presented signal (does not work at Standard text ) must be pressed. Reserved positions for the ana- After entering the variables (e.g. $x or εx) the button log variables will be inserted in the working mode. Example: $_,_ Reserved Positions for the analog-display of the measuring range from If reserved positions will be overwritten, the displayed value of the variable is incorrect. More examples next page
14 GHM-Messtechnik GmbH Standort Martens Variable function examples M Displaying of date and time in Standard text if no alarm appears.. M Displaying of date and time in messages at the time of the incoming signal. Identification possible for time and sequence of the signals. M Displaying of the actual analog measuring value in messages or Standard text. M Displaying of several analog values in the messages, at the time of incoming signal. This function allows to make an analysis for process problems possible. M Identification of the alarm input (identical with input number). Programming examples Line Actual date and time 1 $w, $d.$x.$y $h:$m:$s Line 1 Anzeige Mo, :3:30 Time at indicated input 1 εh:εm:εs Less water 3 Raw water :10:33 Less water Less water raw water Analog value (actual value) 1 Press 6: $1_,_ C Over temperature 1 Press C Over temperature Analog value (process value at time of incoming signal) 1 Press 6: ε1_,_ C Over temperature 1 Press C Over temperature Number of the indicated input 1 $C Door open 1 01 Door open Recording counter 1 Door open, $n Messages 1 Door open 33 Messages Flashing Text 1 [Attention!] No pressure 1 Attention! No pressure
15 - 15 -
16 GHM-Messtechnik GmbH Standort Martens Ordering code: 1. SD Inputs 1 0 digital inputs 1 digital + 8 analog inputs. Real-time clo 0 without 1 with clock 3. Supply voltage 0 30 V AC V AC 4 4 V AC 5 4V DC ±10 % ±10 % ±10 % ±15 % Hz Hz Hz 4. Options 00 without option 5. Additional text (appears in the field for additional text, max. text field 3 mm x 90 mm) 10/05-V1_
Monitoring Relay MR 50
Monitoring Relay MR 50 Standard signals 0/4... 20 m, 0/2... 10 V DC Features M Input standard signals 0/4... 20 m, 0/2... 10 V DC M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Installed
More informationProgr. Universal-Transmitter PMT 50 Signal conditioning - linearization - output characteristic transformation
GHM-Messtechnik GmbH Location Martens Progr. Universal-Transmitter PMT 50 Signal conditioning - linearization - output characteristic transformation Features M Input for standard signals, resistance/poti
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Characteristics Applications System Evaluation connection Media pressure temperature
More informationInsulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V
Insulation Guard IW 0 Monitoring of ungrounded AC- and DC voltage systems up to 690V Features M Time optimized pulse measuring method M Safe monitoring at extreme conditions (frequency converter, phase
More informationRCMS460 and RCMS490 Series
4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.
More informationLINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems -A_D00001_01_D_XXE/09.2015 LIETRAXX -A etwork and system protection (S protection) for
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More informationSUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.
SUPPLY NETWORK ANALYZER CVMk SERIES & CVMk-4C SERIES INSTRUCTION MANUAL ( M 981 171 / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A. ----- Supply network analyzer CVMk and CVMk-ITF ------ Manual 1 / 2 --- Page
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function
More informationKNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2
KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2 4940212 4940217 2018-10-17 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The FIX2 RM 8 H application programme
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationBATCHMATE 1500 Batch Control Computer Technical Bulletin
TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second
More informationE N SHT-1 SHT-1/2 SHT-3 SHT-3/2
Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Content Symbol, Connection... 3 Warning... Characteristics... 5 Technical parameters... 6 Versions of time switches, Load... 7 Description... 8-9 Control...
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationvacon 100 flow ac drives application manual
vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationInstruction manual SMART 96-2 / WG-2 ph
Instruction manual SMART 96-2 / WG-2 ph Stand: 06.09.2015 SMART 96-2 / WG-2 ph / mv Instructions for Installation Configuration PH-mV / Temp. 0...20 ma 4...20mA 20 ma PH-mV / Temp. 0...20 ma 4...20mA 20
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationGrid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21
Data sheet Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 The CM-UFD.M21 is a multifunctional grid feeding monitoring relay for three-phase mains. It provides different monitoring functions
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More information4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd
Digital 7-Day Programmable Timer 4TCD1 Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Installation Instructions
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationConductivity-Converter
Conductivity-Converter compact version separate version Condutec-LF / e Technical Information Operating Instructions Hengesbach GmbH & Co. KG * Schimmelbuschstr. 17 * D-40699 Erkrath * Tel.: +49 (0) 21
More informationDevice manual Multifunction display and evaluation system FX 360. Mode/Enter
Device manual Multifunction display and evaluation system FX 360 7390275 / 08 07 / 2009 Mode/Enter Set Safety instructions This manual is part of the unit. It contains texts and diagrams for the correct
More informationNote The module converts unipolar and bipolar input signals
PROGRAMMABLE ANALOG SIGNAL CONVERTER THREE WAY GALVANIC ISOLATOR - 19 input scales - 7 output scales - 1 SPDT alarm contact - input/output isolation 3kV - auxiliary supply output for loop powered sensors
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationEnglish. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM
English Operating manual Temperature measuring transducer MU125 Company / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents Page 1. Intended use (areas of application)...
More information+GF+ SIGNET Temperature Transmitter Instructions
GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal
More informationNRT 105: Electronic fan-coil controller, equiflex
Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/020 0277078 RN 5897/020 RP 5898 Product Description The insulation monitor RN 5897/020 of the VARIMETER IMD family provides best and up to
More informationS200 I/O System Units
S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features
More informationInstallation and Operating Instructions. Power IT Power Factor Controller RVC
Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...
More informationInstruction manual SMART 96-2 / WG-2 LF
Instruction manual SMART 96-2 / WG-2 LF Stand: 06.09.2015 SMART 96-2 / WG-2 conductivity Instructions for Installation Configuration ANALOG 2 EC / Temp. 0...20 ma 4...20mA 20 ma ANALOG 1 EC / Temp. 0...20
More informationALPTEC POWER FACTOR CONTROLLER
ALPTEC POWER FACTOR CONTROLLER ALPTEC3 ALPTEC5 ALPTEC7 ALPTEC12 0 REF : 2008-ALPTEC3.5.7.12-01-ANG CONTENTS I GENERAL INFORMATION. 2 II WAYS TO SET UP THE CONTROLLER.. 4 III OPERATING MODE..6 IV ADVANCED
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationReactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau
Reactive Power Control Relay RM 2106 / 2112 Operating Instructions FRAKO Kondensatoren- und Anlagenbau www.frako.com Figure 1 Front view a b c d e Display for active capacitor stages Display for inductive
More information8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE
8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...
More informationInstruction manual. art Installation manual
Instruction manual art. 01521 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 4 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL FEATURES AND
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationPhotoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs
Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic
More informationME162 Single-Phase Electronic Meter
Energy Measurement and Management ME162 Single-Phase Electronic Meter Technical Description Version 1.1, 02.06. 2006 Index: ME162 Electronic single-phase time-of-use kwh-meter... 3 1. Meter appearance...
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationKNX manual 1-channel flush-mounted switch actuator SU 1
KNX manual 1-channel flush-mounted switch actuator SU 1 4942520 2018-10-04 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The SU 1 application programme 7 4.1 Selection in the product
More informationBU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS
INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported
More informationTrip amplifier, 1 channel
Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationMultifunctional counter tico 772/773/774
Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC320 Process Controller
More informationCount - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2
Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationTechnical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay
Technical Datasheet RELAY-1 RISHABH k V RESET True RMS Digital Protection Relay RELAY-2 TEST True RMS Measurement RISH Relay V is used to protect against Over Voltage, Under Voltage, Phase Sequence detection,
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationUniversal Controller
7 863 Universal Controller POLYGYR RWF32... ISO 9001 RWF32... with casing ARG61.01 The RWF32... is a universal digital boiler temperature / pressure controller designed for use in oil- and / or gas-fired
More informationGuidelines to Using a Three Phase Voltage Monitor
September 2000 Guidelines to Using a Three Phase Voltage Monitor Introduction A phase monitor can be used with any three phase motor. A monitor such as the Copeland 085-0160-00 is recommended for monitoring
More informationQuick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB
DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks
More informationElectromagnetic flowmeters Transmitter types MAG 5000, MAG 6000
s Operating Manual Edition 05/2006 - Revision 05 SITRANS F M MAGFLO Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000 [ ] Technical Documentation (handbooks, instructions, manuals etc.) on
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationSentry Digital Timers
Sentry Digital Timers 0733s S4 Contents 1. Safety precautions 2. General rmation 3. DIN rail Installation 4. Display Layout. Programming 6. Technical Data 7. Guarantee 2 Safety precautions The connection
More informationMonitoring Relays 3-Phase Active power direction Types DWB03, PWB03
Monitoring Relays 3-Phase Active power direction ypes DWB03, PWB03 DWB03 PWB03 RMS active power relays for three phase balanced applications Measuring if active power is within set limits Measure their
More informationOperating Manual MU2000K
ZIEHL industrie elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN
More informationluxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor
ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel)
More informationISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet iso685-x-b_d00177_04_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems
More informationSUNDIAL Light Dimmer. User's Manual
Light Dimmer User's Manual 1. PRECAUTIONS Although fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection
More informationISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances
ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) iso685-x_d00022_08_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationAssembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail
Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationAnalyzer Twin. k +49 (0) / (0) / General Agent Germany:
Combined Instrument for Quartz and Mechanical Watches This combined measurement and test instrument associates all functions of test equipments for quartz watches and test equipments for mechanical watches.
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationTechnical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay
Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationTC 204 Heating Controller
TC 204 Heating Controller ver. 1.32-01 The TC204 is a multi-purpose heating controller with built-in programs for different types of heating systems. General Data Power requirement 24 volts ac, 2 va Inputs
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed
More informationMCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.
Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long
More informationSupercal 531 Multi function Integrator that lives up to Your highest expectations
n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationTime Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001
, GH Q605 0062 R0001 The 2-fold week time switch is a DIN rail mounted device with a width of two modules for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal.
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric
More informationMonitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71
Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 DPC71 PPC71 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect
More informationPassive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
More information96M0374. Instruction Manual. Analog Sensor Controller. RD Series
Instruction Manual Analog Sensor Controller RD Series 96M0374 Safety precautions This manual describes how to install the RD Series as well as its operating procedures and precautions. Please read this
More information