1 Transformer Protection by Using Arduino with GSM Modem Prof. R. B. Pandhare 1,Mr. ParmanandWaghmare 2, Ms. Ashvini Gawande 3, Mr. Gopal Bahekar 4, Ms. Rekha Ghate 5 Department of Electrical Engineering 1,2,3,4,5, faculty of Electrical Engineering 1 Students of Electrical Engineering 2,3,4,5 profpandhare@gmail.com 1,waghmare8526@gmail.com 2 ashvinigawande12@gmail.com 3,bahekargopal16@gam il.com 4, 24rekhaghate@gmail.com 5 Abstract:-Distribution transformer is a main element for electrical energy transfer in electrical power systems. Prevent the distribution transformer damage due to the overloading currents, over-heatingof transformers oiland high voltage spikes. So, relevant protection of transformer is very crucial for continuity ofpower supply. In this protective strategy is implemented by using of Arduinocontroller that is cost powerful deviceandtremendous high speed with high accuracy. The controller sense the temperature of transformer and current of load continuously. The rating of voltage and currentreaches from its pre-setvalues, protection scheme operates and trips the load. As temperature reaches to threshold value set in system, a fan would turn on for the cooling of the heated transformer. During the testing a special type of transformer that is i.e. autotransformer is used to vary the input voltage of the transformer to generate over voltage and under voltage fault. To occur the over current fault we increase load by using bulbs. If any emergency or aberrantconditions occur the system sends information through SMS to the mobile phones, by using GSMModem. At the end, successful results have been justifying the proposed technique and identify problems before any failure. Keywords:-Distribution transformer, potential transformer, Current transformer, Arduino, GSM, Relay. 1. INTRODUCTION Distribution transformer is electrical equipment which is utilized to step down the voltage without change in frequency. In this paper a protection system has been fabricated in such a way that system is monitoring the real time based, operating flexible of the transformer continuously and these parameters are viewed on the LCD display. In the LCD display unit we can view the continuous parametric information of transformer. In this research work a potential transformer is used for step down the line voltage for measuring purposes and current transformer is acting as a current sensor. The C.T. place in series and P.T. is shunt to the transformer.thermistor is utilized to measure the temperature of transformer oil. Relays are used to carry out the tripping mechanism. Voltage and currents aremeasured using A/D converter of microcontroller. A/Dconverter converts the values of analog current and voltage value to the digital value. Then according to the code, values are compared with the preset values in the controller if excess in any parameter occur a relay would trip the transformer upon exceeding the limit of current and voltage. If temperature increases from preset value, a fan would be turn on using relay. The voltage, temperature and current values are displayed on the LCD. It is also has the advantages of significant cost savings, power consumption and greater reliability. In this system, Arduino microcontroller is used to monitor cases of electrical faults and communicate to a switch to detachthe transformer from the system. 2. LITERATURE REVIEW Electric Power system an electric Power system refers to a network that constitutes electrical components/machines used in the supply, transmission and digestion of electric power. The figure shows below clarification a complete power electric system. It involves generation, transmission and distribution of electric power to various categories of consumers. The generation plant is normally located far from the load center. There are different levels of electric power consumption depending on the motive for which a customer uses electricity. Electrical power consumers may be commercial, domestic orindustrial [3]. These consumers require different levels of electric power supply. In order to meet their specific requirement, certain devices that adjust the voltage levels accordingly have to be used. Some of those components include prevent devices, capacitor banks, step down and step up transformersetc. 119

2 Figure1:-Generation, transmission and distribution of electrical power 3. PROBLEM STATEMENT Transformer is electrical element that changes the voltage from one level to other level without change in frequency. Transformer is more expensive device in power system. As the load increase at secondary winding of the transformer form its rated value [1]. Due to short circuit or instantly increase in load can cause overloading, over-voltages and overheating that can damage the insulation of transformer windings and severe damage can be occur on the secondary side. The various types of faults that cause the transformer failures are winding faults, faults due to over currents, over voltage faults, earthing faults, insulation failure faults and bushing flashover faults [4]. So, for overcome above problems a reliable and speedy protection with more accuracy is needed. In this paper a protection scheme is purposed that addresses the above stated problems. Power system protection is a vital consideration in the design of an electrical power system. There is need to protect electrical power components from dangerous faults. This is warranted by the need to improve the life of the components, avoid dispersible expenditure in frequent replacement of obsolete components and to ensure that there is a continuous supply of power to serve the needs of the ever growing economy. This paper therefore seeks to design a microcontroller based system that will intelligently monitor faults and prompt a safety measure to protect the power transformer in case of power overload. 4. PROPOSED TECHNIQUE Methodology of purposed protection scheme is shown in following figure (2) with the help of block diagrams. The brain of the scheme is Arduino board [5]. Detailed description and circuit of each block is given below. Figure 2:- Block Diagram. 4.1 Current Transformer (C.T.) The C.T. is act as current sensor which is place series with the load. Basic function of current transformer is to step down and calculate the current. C.T load of 10ῼ is connected on secondary winding of C.T. For calibration purpose the pots (Variable resistor) areis used.[6]. Then AC signal rectification DC analog signal is transferred to the analog pin of Arduino Board Platforms analog pin. Real time picture and current sensing circuit is given below. Figure 3:- Current sensing circuit 4.2Potential Transformer (P.T.) The Potential transformer is act as voltage sensor which is used to sense or measure the voltage flow from the system. The potential transformer place parallel to the load [6]. The bridge rectifier convert AC voltages into DC voltage and attached to the analog pin of microcontroller. For calibration purpose the pots (Variable resistor) are is used. The voltage sensing circuit is shown figure (4). 120

3 4.3 Relay Circuit Figure 4:- Voltage Sensing Circuit Figure 6:-Temperature sensor interfacing with Arduino 4.5 LCD Display LCD is used to show all result on screen. In research 16pin (LMB162AFC) LCD is used to display the parameters of transformer such as voltage, current and temperature. Arduino Platform communicates with the LCD using serial communication protocol. Hardware connections are shown in figure (7). Figure 5:- Relay Circuit The function of relay is to disconnect the supply when the abnormal condition is happened. The relay circuit is connected to Arduino Board with using of opto-coupler (pc817). Opto-coupler is used for protects the microcontroller from high voltage spikes [6] and the isolation purpose. The transistor is used in relay circuit to operate the relay. The output of Arduinobecome high, the relay circuit will operate and trips the load. The relay circuit is also shown in figure (5). 4.4 Temperature sensor interfacing with Arduino Thermistor is cheap and easily-obtainable temperature sensors. It is very easy to use and adaptable. Circuits with thermistor can have reliable output voltages not the mv outputs thermocouples have. Because of these properties thermistor are usually used for easy measurement of temperature. Thermistors are not used for high temperatures. Resistor of 10 k-ohms is used to linearize the output of thermistor. Hardware connections are shown in the given figure (6). 4.6 GSM Modem Figure 7:- LCD interfacing with Arduino Figure 8:- GSM modem A GSM Modem is operating on same principal of mobile phone. It is uniquetype of modem which receives a sim card and operates over contribution to a mobile operator, as like a mobile phone. From the mobile operator perspective.the GSM is interface with the arduino and it is used to send the information to the consumer about the faulty condition of the system through the SMS. 4.7 Arduino Circuit Arduino Uno is used for implementing the digital controller. Arduino Uno is an AVR based upon microcontroller board. It has ATmega328 microcontroller and other onboard peripherals including 16 MHz crystal [7]. Programming is done in C language [8]. Detailed Arduino board diagram is shown in figure (9). 121

4 temperature increases more than the pre-set value then the circuit will trip and the fan is ON. Figure 9:-Arduino Circuit 5. RESULTS/LAB TESTING Lab testing is performed on 1A current, 190Vmin to 265Vmax voltages and 45C temperature settings. When the rating of current and voltage is reaches its defined value, then the load is cut-off. Also the temperature reaches it limits then fan would be turn on for cooling the transformer. If current would or voltage would over s its defined limits then load would be cut-off and as the temperature limit reaches, cooling fan would be turn ON Testing results are as given below. Table1. Effect of over voltage and under voltage Sr. No. Voltage Load (lamp) 1 < 190 V OFF 2 Between 190V - 265V ON 3 >265V OFF Table 2 Effect of load variation Sr. No. Current Load 1 0.4A 1 Lamp ON 2 0.8A 2 Lamp ON 3 1.2A 3 Lamp/Load Trips Table3. Effect of temperature variation Sr. No. Temperature (C) Fan 1 <45 C OFF 2 >45 C ON 6. CONCLUSION From this project we can i. Calculate the current flowing through the circuit and analyzed it. The C.T. is to used to measure the current and displayed on the LCD display. ii. The relay is used for tripping operation. when the fault is occur due to overloading or over voltages then microcontroller will energies the relay coil to trip the circuit. iii. The temperature measure by using temperature sensor which is interface with arduino. The REFERENCES [1] Hase, Y. (2007) Handbook of Power System Engineering. John Wiley & Sons Ltd, England, [2] Electrical4u. electrical4u.com. [Online] [3] Fundamentals of Power System Protection by ByYeshwant G. Paithankar, S. R. Bhide [4] Cristina CIULAVU, Elena HELEREA Power Transformer Incipient Faults Monitoring Annals of University of Cariova, Electrical Engineering Series, No, 32, 2008; ISSN [5] Thien-Bach Huynh, Leon Hardy, Mark Pezzo, and Otis Wilder The Testing and Design of an ArduinoMicrocontroller Board for the Study of Proxemics University of South Florida St. Petersburg Student Research Journal Volume 2 Issue 1: 01 October 2012 [6] Hobson, A Instrument Transformers IET Journals & Magazines Volume: 91, Issue: 20 January 2010 [7] Don Wilcher, Learn Electronics with Arduino, illustrated Edition, Apress, 2012 [8] YashavantP.Kanetkar, Let us C, 12th Edition, BPB Publications, Prof. R. B. Pandhare H.O.D.of Electrical Engineering 2. Mr. Parmanand D. Waghmare Student of Electrical Engineering 3. Ms. Ashvini S. Gawande Student of ElectricalEngineering 122

5 4. Mr. Gopal V. Bahekar Student of ElectricalEngineering 4. MsRekha S. Ghate Student of Electrical Engineering 123

SIMULATION OF TRANSFORMER PROTECTION USING MICROCONTROLLER BASED RELAY & MONITORING USING GSM

SIMULATION OF TRANSFORMER PROTECTION USING MICROCONTROLLER BASED RELAY & MONITORING USING GSM SIMULATION OF TRANSFORMER PROTECTION USING MICROCONTROLLER BASED RELAY & MONITORING USING GSM 1 Shweta Mate, 2 Shital Jagtap, 3 B.S. Kunure Department of Electrical Engineering, ZCOER, Pune, India Abstract

More information

Automatic Load Sharing of Transformers using Microcontroller

Automatic Load Sharing of Transformers using Microcontroller Automatic Load Sharing of Transformers using Microcontroller Akhil Krishnan V 1, Arun P S 1, D Yathishan 1, Jomice Thomas 1, D K Narayanan 2 U.G. Students, Department of Electrical and Electronics Engineering,

More information

AUTOMATIC METHOD OF PROTECTING TRANSFORMER USING PIC MICROCONTROLLER AS AN ALTERNATIVE TO THE FUSE PROTECTION TECHNIQUE A. Z. Loko 1, A. I. Bugaje 2, A. A. Bature 3 1 Department of Physics Electronics/Nasarawa

More information

Feeder Protection From Over Load and Earth Fault Relay

Feeder Protection From Over Load and Earth Fault Relay Feeder Protection From Over Load and Earth Fault Relay Prof. Vaneela Pyla 1, Uma N. Bhimnath 2, Archana M. Bhosale 3, Apurva V. Khachane 4 Assistant Professor, Electrical Engineering Department, NBN Sinhgad

More information

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION HARSH DHIMAN Department of Electrical Engineering, The M. S. University, Vadodara,

More information

Design and Implementation of High Precision Automated Online Monitoring of Distribution Transformer (OMDT) Device

Design and Implementation of High Precision Automated Online Monitoring of Distribution Transformer (OMDT) Device Design and Implementation of High Precision Automated Online Monitoring of Distribution Transformer (OMDT) Device Beena M Varghese Associate professor, EEE department, Mar Athanasius College of Engineering

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 5.71 e-issn (O): 2348-4470 p-issn (P): 2348-6406 International Journal of Advance Engineering and Research Development A National Conference On Spectrum Of Opportunities

More information

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3 RESEARCH ARTICLE International Journal of Engineering and Techniques - Volume 4 Issue 1, Jan Feb 2018 Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2,

More information

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM Md.Imran 1, R.Surender Reddy 2 1 Md.Imran, Mtech Student, Lords Institute of Engineering and Technology, Himayath sagar, Telangana, India 2 R.Surender Reddy,

More information

Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm

Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm Ramadas.K 1, Madasamy.P 2 1, 2 Assistant Professor, Department of Electrical and Electronics Engineering, Aliquippa Chettiar College

More information

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM KIRAN DILIP DESAI 1, RAMCHANDRA P.HASABE 2 Electrical Engg.Department, Walchand College of Engg., Sangli.

More information

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction:

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction: GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction: Electricity is an extremely handy and useful form of energy. It plays an ever growing role in our modern industrialized

More information

Digital Monitoring Cum Control of a Power Transformer with Efficiency Measuring Meter

Digital Monitoring Cum Control of a Power Transformer with Efficiency Measuring Meter Digital Monitoring Cum Control of a Power Transformer with Efficiency Measuring Meter Shaikh Ahmed Ali, MTech(Power Systems Control And Automation Branch), Aurora s Technological and Research institute(atri),hyderabad,

More information

Mobile Agent Based Intelligence Power Distribution Control System

Mobile Agent Based Intelligence Power Distribution Control System IJIRST International Journal for Innovative Research in Science & Technology Volume 4 Issue 11 April 2018 ISSN (online): 2349-6010 Mobile Agent Based Intelligence Power Distribution Control System Pratik

More information

International Journal of Engineering Trends and Technology (IJETT) Volume 50 Number 1 August 2017

International Journal of Engineering Trends and Technology (IJETT) Volume 50 Number 1 August 2017 Over current Protection of Transmission Line using GSM and Arduino Kunal Jagdale *1, A.Siddhartha Rao *2 #1, 2, Bachelor of Engineering, Dept. of Electrical Engineering, SVITS, Indore, India Abstract This

More information

AC Overload Tester for Magnet Wire

AC Overload Tester for Magnet Wire 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435 450 465 480 495 510 525 540 555 570 585 600 615 630 645 660 675 690 705 720 735 750 765 780

More information

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Numbering System for Protective Devices, Control and Indication Devices for Power Systems Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements

More information

AN EMBEDDED 1/3 PHASE AUTOMATIC TRANSFER SWITCH WITH INTELLIGENT ENERGY MANAGEMENT

AN EMBEDDED 1/3 PHASE AUTOMATIC TRANSFER SWITCH WITH INTELLIGENT ENERGY MANAGEMENT International Journal of Computer Engineering and Applications, Volume IX, Issue V, May 2015 www.ijcea.com ISSN 2321-3469 AN EMBEDDED 1/3 PHASE AUTOMATIC TRANSFER SWITCH WITH INTELLIGENT ENERGY MANAGEMENT

More information

International Journal Of Core Engineering & Management Volume-4, Issue-11, February-2018, ISSN No:

International Journal Of Core Engineering & Management Volume-4, Issue-11, February-2018, ISSN No: DESIGN AND IMPLEMENTATION OF INTELLIGENT CIRCUIT BREAKER FOR ELECTRICAL CURRENT SENSING AND MONITORING Hamzah M. Marhoon, Department of Computer Techniques Engineering, Al-Esra'a University College Karadah,

More information

LOAD SHARING OF TRANSFORMERS BASED ON MICROCONTROLLER

LOAD SHARING OF TRANSFORMERS BASED ON MICROCONTROLLER LOAD SHARING OF TRANSFORMERS BASED ON MICROCONTROLLER Piprotar Khyati 1, Sakariya Dimpal 2, Thummar Bhumika 3, Bodar Geeta 4 Students, Professor, Department of Electrical Engineering, Shree Swami Atmanand

More information

Transformer Health Condition Monitoring Through GSM Technology

Transformer Health Condition Monitoring Through GSM Technology Transformer Health Condition Monitoring Through GSM Technology 1 Linganagouda.R, 2 Tasleem, 3 Rizwana.Shaik, 4 Tasmiya Rahil.V, 5 Shailaja.V 1 Asst.prof,EEE Dept 2345 8th sem,eee Dept Abstract- Transformers

More information

Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT

Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT GRD Journals Global Research and Development Journal for Engineering National Conference on Emerging Research Trend in Electrical and Electronics Engineering (ERTEE-2018) March 2018 e-issn: 2455-5703 Smart

More information

International Journal of Scientific Research and Reviews

International Journal of Scientific Research and Reviews Research article Available online www.ijsrr.org ISSN: 2279 0543 International Journal of Scientific Research and Reviews Arduino Based Drinking Water Bill Calculator Using GSM Technology Karthikeyan Sundarasamy

More information

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani Abstract Aim of this research is to help a remote user to remain in touch with what

More information

Auto Selection of Any Available Phase in 3 Phase Supply System

Auto Selection of Any Available Phase in 3 Phase Supply System Auto Selection of Any Available Phase in 3 Phase Supply System Prof. Praful Kumbhare 1, Pramod Donode 2, Mahesh Nimbulkar 3, Harshada Kale 4, Mayur Waghamare 5, Akansha Patil 6, 1, 2, 3, 4, 5, 6 Department

More information

WIRELESS THREE PHASE LINE FAULT MONITORING

WIRELESS THREE PHASE LINE FAULT MONITORING WIRELESS THREE PHASE LINE FAULT MONITORING Vaishnavi Kailas Pardeshi 1, Pooja Anil Kawade 2, Rutuja Ratanakar Kshirsagar 3 1,2,3 Department Electrical Engineer, Sandip Polytechnic, Nashik Maharashtra (India)

More information

Over Current Protection Relay using Arduino Uno for Future Renewable Electric Energy Delivery and Management (FREEDM) System

Over Current Protection Relay using Arduino Uno for Future Renewable Electric Energy Delivery and Management (FREEDM) System Over Current Protection Relay using Uno for Future Renewable Electric Energy Delivery and Management (FREEDM) System Mohamed. F. Kotb, Magdi El-Saadawi, and Eman H. El-Desouky Abstract The FREEDM (Future

More information

Wireless Automated Transmission System For Guarding or Health Monitoring Of High Voltage Transformer

Wireless Automated Transmission System For Guarding or Health Monitoring Of High Voltage Transformer Wireless Automated Transmission System For Guarding or Health Monitoring Of High Voltage Transformer Mr. V. B. Patil 1,Patil Pooja 2, Patil Dhanashree 3, More Tejaswini 4, Ghewari Vinayak 5, Patil Shailesh

More information

International Journal of Advance Engineering and Research Development. Transformer Health Monitoring And Control Through Arduino

International Journal of Advance Engineering and Research Development. Transformer Health Monitoring And Control Through Arduino Scientific Journal of Impact Factor (SJIF): 5.71 International Journal of Advance Engineering and Research Development Volume 5, Issue 04, April -2018 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Transformer

More information

DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM

DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM Shunmugam.R 1, Ashok kumar.k 2, Deebika Devi.A.R 3, Manoj Kumar.K 4, Mathivanan.A.M 5 1 Atssociate professor,electrical And Electronics Engineering,

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

Simulation & Realization of Feeder Protection with Micro Controller

Simulation & Realization of Feeder Protection with Micro Controller International Journal of Electrical Engineering. ISSN 0974-2158 Volume 9, Number 1 (2016), pp. 57-65 International Research Publication House http://www.irphouse.com Simulation & Realization of Feeder

More information

A Review on Load Sharing of Transformer

A Review on Load Sharing of Transformer IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 07 January 2017 ISSN (online): 2349-784X A Review on Load Sharing of Transformer Mohammad A. Lakdawala Bhavik Patel Vaibhav

More information

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC Shubhangi Landge¹, Snehal Waydande², Sanjay Sangale³, Somesh Gaikwad⁴ ¹Assistant Professor, Dept. Of Electrical Engineering, AISSMS IOIT College,

More information

Control of Lighting System

Control of Lighting System EE318 Electronic Design Lab Project Report, EE Dept, IIT Bombay, April 2009 Control of Lighting System Group No: D13 Bharat Bhushan (06d04026) Sravan Kumar Jatavath (06d07018)

More information

Substation Monitoring System

Substation Monitoring System Substation Monitoring System Amol Ram Kate 1, Girish Baban Dongare 2, Krishana Maroti Janwade 3, Payal Burande 4, Narendra P. Zinjad 5 1,2, 3 UG Students 4, 5 Assistant Professor 1 Department of Electrical

More information

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION GSM BASED DISTRIBUTION TRANSFORMER MONITORING SYSTEM Bhakare Govind A. 1, Dabe Nilesh P. 2,Pawar S. D. 3. 1 UG Student, Electrical Engineering, ATCFOE, Ahmednagar, Maharashtra, India 2UG Student, Electrical

More information

DESIGN OF TEMPERATURE BASED SPEED CONTROL SYSTEM USING ARDUINO MICROCONTROLLER

DESIGN OF TEMPERATURE BASED SPEED CONTROL SYSTEM USING ARDUINO MICROCONTROLLER Int. J. Chem. Sci.: 14(S3), 2016, 753-760 ISSN 0972-768X www.sadgurupublications.com DESIGN OF TEMPERATURE BASED SPEED CONTROL SYSTEM USING ARDUINO MICROCONTROLLER KANISHAK KESARWANI, S. M. PRANAV, TANISH

More information

SUBSTATION MONITORING AND CONTROL SYSTEM

SUBSTATION MONITORING AND CONTROL SYSTEM SUBSTATION MONITORING AND CONTROL SYSTEM Mr.S.S.Ghodhade #1,Dhiraj.D.Patil #2,Ajaykumar.S.Pujari #3,Sachin.S.Ayarekar #4, Prakash.B.Bandgar #, Ashwini.S.Waghmare #6 Assistant Prof. #1, Department of Electrical

More information

World Journal of Engineering Research and Technology WJERT

World Journal of Engineering Research and Technology WJERT wjert, 2018, Vol. 4, Issue 4, 300-306. Original Article ISSN 2454-695X Sarkar. WJERT www.wjert.org SJIF Impact Factor: 5.218 EARTH FAULTED EQUIPMENT INDICATION SYSTEM FOR ISOLATED NEUTRAL SYSTEM Prosanjeet

More information

Transformer Health Monitoring System

Transformer Health Monitoring System Transformer Health Monitoring System Nagargoje Dnyaneshwar 1, Kankate Akshay 2, Singh Akash 3, U.V. Patil 4 Dept. of Electronics and telecommunications Engg. 1,2,3,4, P.R.E.C Loni, Maharashtra, India Email:

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS - GSM TECHNIQUE USED FOR UNDERGROUND CABLE FAULT DETECTOR AND DISTANCE LOCATOR R. Gunasekaren*, J. Pavalam*, T. Sangamithra*, A. Anitha Rani** & K. Chandrasekar*** * Assistant Professor, Department of Electrical

More information

International Journal of Advance Engineering and Research Development PROTECTION OF TRANSFORMERS USING SENSORS

International Journal of Advance Engineering and Research Development PROTECTION OF TRANSFORMERS USING SENSORS Scientific Journal of Impact Factor (SJIF): 5.71 International Journal of Advance Engineering and Research Development Volume 5, Issue 04, April -2018 e-issn (O): 2348-4470 p-issn (P): 2348-6406 PROTECTION

More information

AC POWER CONTROL USING ANDROID CELLPHONE WITH LCD DISPLAY

AC POWER CONTROL USING ANDROID CELLPHONE WITH LCD DISPLAY Journal of Advanced Research in Engineering ISSN: 2394-2819 Technology & Sciences Email:editor@ijarets.org May-2016 Volume 3, Issue-5 www.ijarets.org AC POWER CONTROL USING ANDROID CELLPHONE WITH LCD DISPLAY

More information

PERFORMANCE ANALYSIS OF MICROCONTROLLER BASED ELECTRONIC LOAD CONTROLLER

PERFORMANCE ANALYSIS OF MICROCONTROLLER BASED ELECTRONIC LOAD CONTROLLER ORIGINAL RESEARCH ARTICLE OPEN ACCESS PERFORMANCE ANALYSIS OF MICROCONTROLLER BASED ELECTRONIC LOAD CONTROLLER Amir Raj Giri *, Bikesh Shrestha, Rakesh Sinha Department of Electrical and Electronics Engineering,

More information

GSM Based Automatic Wireless Energy Meter Reading System P. Harish M.Tech, S. Sandeep M.Tech,

GSM Based Automatic Wireless Energy Meter Reading System P. Harish M.Tech, S. Sandeep M.Tech, GSM Based Automatic Wireless Energy Meter Reading System P. Harish M.Tech, S. Sandeep M.Tech, Asst.Professor, Dept.of ECE, SVPCET, RVS Nagar, Puttur. Asst. Professor, Dept. of ECE, SVPCET, RVS Nagar, Puttur.

More information

INTELLIGENCE HOME AUTOMATION SYSTEM USING LDR

INTELLIGENCE HOME AUTOMATION SYSTEM USING LDR INTELLIGENCE HOME AUTOMATION SYSTEM USING LDR Priyadarshni.S 1, Sakthigurusamy.S 2,Susmedha. U 3, Suryapriya.M 4, Sushmitha. L 5, Assistant Professor 1, Student members 2,3,4,5 Department of Electronics

More information

e-automatic MOTOR CONTROL SYSTEM

e-automatic MOTOR CONTROL SYSTEM e-automatic MOTOR CONTROL SYSTEM Mr. G.Venkata Prasad 1, Mr.P.Shanker 2 1,2 Assistant Professor, Department of CSE, Sphoorthy Engineering College, Hyderabad ABSTRACT In this paper e-automatic MOTOR CONTROL

More information

IOT Based Smart Greenhouse Automation Using Arduino

IOT Based Smart Greenhouse Automation Using Arduino IOT Based Smart Greenhouse Automation Using Arduino Prof. D.O.Shirsath, Punam Kamble, Rohini Mane, Ashwini Kolap, Prof.R.S.More Abstract Greenhouse Automation System is the technical approach in which

More information

Monitoring Temperature using LM35 and Arduino UNO

Monitoring Temperature using LM35 and Arduino UNO Sharif University of Technology Microprocessor Arduino UNO Project Monitoring Temperature using LM35 and Arduino UNO Authors: Sadegh Saberian 92106226 Armin Vakil 92110419 Ainaz Hajimoradlou 92106142 Supervisor:

More information

A digital DC powersupply

A digital DC powersupply LinuxFocus article number 379 http://linuxfocus.org A digital DC powersupply Abstract: by Guido Socher (homepage) About the author: Guido likes Linux because it is a really good system to develop your

More information

Monitoring And Control Over Power Factor By Using Pic Micro-Controller

Monitoring And Control Over Power Factor By Using Pic Micro-Controller International Journal Of Scientific Research And Education Volume 2 Issue 7 Pages 1351-1363 July-2014 ISSN (e): 2321-7545 Website: http://ijsae.in Monitoring And Control Over Power Factor By Using Pic

More information

MDSRC Proceedings, December, 2017 Wah/Pakistan

MDSRC Proceedings, December, 2017 Wah/Pakistan Three Phase Frequency Converter Quratulain Jamil 1, Hafiz Muhammad Ashraf Hayat 2, Haris Masood 3 1 Department of Electrical Engineering Wah Engineering College, University of Wah jamil0265@gmail.com 2

More information

ADVANCES in NATURAL and APPLIED SCIENCES

ADVANCES in NATURAL and APPLIED SCIENCES ADVANCES in NATURAL and APPLIED SCIENCES ISSN: 1995-0772 Published BYAENSI Publication EISSN: 1998-1090 http://www.aensiweb.com/anas 2017 Special 11(4): pages 1-7 Open Access Journal Data Acquisition System

More information

Universal Protection System for Ac Industrial Motors

Universal Protection System for Ac Industrial Motors Universal Protection System for Ac Industrial Motors Mr. Ibrahim Rawat 1, Mr. Saurabh Patel 2, Mr. Akshil Chauhan 3, Mr. Nisargkumar Parmar 4, Mr. Sunil Malival 5 1234 B.E Students, ITM Universe, Vadodara

More information

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes

More information

Automated E-Billing and Supply Control using Power Line Communication

Automated E-Billing and Supply Control using Power Line Communication Automated E-Billing and Supply Control using Power Line Communication Vishal Salunke 1, Datta Barsale 2, Rushikesh Kashid 3 Jagadeesh Hallur 4 123 Student, Dept of E&TC, DYPSOET, Maharashtra, India 4 Asst.

More information

HOME AUTOMATION A Prototype to control home appliances automatically

HOME AUTOMATION A Prototype to control home appliances automatically Volume 119 No. 15 2018, 737-741 ISSN: 1314-3395 (on-line version) url: http://www.acadpubl.eu/hub/ http://www.acadpubl.eu/hub/ HOME AUTOMATION A Prototype to control home appliances automatically A.Selvapandian

More information

DLVP A OPERATOR S MANUAL

DLVP A OPERATOR S MANUAL DLVP-50-300-3000A OPERATOR S MANUAL DYNALOAD DIVISION 36 NEWBURGH RD. HACKETTSTOWN, NJ 07840 PHONE (908) 850-5088 FAX (908) 908-0679 TABLE OF CONTENTS INTRODUCTION...3 SPECIFICATIONS...5 MODE SELECTOR

More information

AUTOBOOK The Messaging Machines (Using GSM and Arduino)

AUTOBOOK The Messaging Machines (Using GSM and Arduino) AUTOBOOK The Messaging Machines (Using GSM and Arduino) Vidya Sneha.V 1, Sadhve.V 2, Swathi.J 3 Department of Electronics and Instrumentation Engineering Easwari Engineering College, Chennai. Abstract:

More information

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS Ljubomir KOJOVIC Cooper Power Systems - U.S.A. Lkojovic@cooperpower.com INTRODUCTION In steel facilities that use Electric Arc Furnaces (EAFs) to manufacture

More information

Smart Energy Meter with Advanced Features and Billing System

Smart Energy Meter with Advanced Features and Billing System 2019 4 th International Electrical Engineering Conference (IEEC 2019) Jan, 2019 at IEP Centre, Karachi, Pakistan Smart Energy Meter with Advanced Features and Billing System Mubashar Hasnain Tahir 1*,

More information

Design and Development of Pre-paid electricity billing using Raspberry Pi2

Design and Development of Pre-paid electricity billing using Raspberry Pi2 International Journal of Electronics Engineering Research. ISSN 0975-6450 Volume 9, Number 7 (2017) pp. 995-1005 Research India Publications http://www.ripublication.com Design and Development of Pre-paid

More information

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation Excitation Systems Compound-Excitation System for Synchronous Generators Power Generation Operating Characteristics Load dependent Short circuit supporting Low voltage gradient dv/dt Black start capability

More information

A Super trainer with advanced hardware and software features only found in very expensive equipment.

A Super trainer with advanced hardware and software features only found in very expensive equipment. PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such

More information

GSM BASED AGRICULTURE MONITORING SYSTEM

GSM BASED AGRICULTURE MONITORING SYSTEM GSM BASED AGRICULTURE MONITORING SYSTEM Aprajita Anand 1, Akansha Parasar 2, Assoc. Prof. A Prabhakar 3 1.2Btech in Electronics and telecommunication engg. BVDUCOE,Pune,Maharashtra,India 3Assoc. Professor

More information

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated Rev. D CE Series Power Amplifier Service Manual 3 Circuit Theory 3.0 Overview This section of the manual explains the general operation of the CE power amplifier. Topics covered include Front End Operation,

More information

SIGNAL INTERFACE MODULE

SIGNAL INTERFACE MODULE SIGNAL INTERFACE MODULE FEATURES Optically isolated inputs Field adjustable output Second onboard DC supply Positive / negative voltage output APPLICATIONS Phase cut to ma / VDC conversion Signal scaling

More information

ARDUINO-BASED TEMPERATURE MONITOR- ING AND CONTROL VIA CAN BUS MOHAMMAD HUZAIFAH BIN CHE MANAF UNIVERSITI MALAYSIA PAHANG

ARDUINO-BASED TEMPERATURE MONITOR- ING AND CONTROL VIA CAN BUS MOHAMMAD HUZAIFAH BIN CHE MANAF UNIVERSITI MALAYSIA PAHANG ARDUINO-BASED TEMPERATURE MONITOR- ING AND CONTROL VIA CAN BUS MOHAMMAD HUZAIFAH BIN CHE MANAF UNIVERSITI MALAYSIA PAHANG ii ARDUINO-BASED TEMPERATURE MONITORING AND CONTROL VIA CAN BUS MOHAMMAD HUZAIFAH

More information

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection. QTMS The transformer monitor shall provide data integration platform, cooling supervision & monitoring. User configurable without need of a technician, a 100% configurable to specific customer requirement.

More information

Power Pulse Modulator A High Performance Versatile Square Pulse Generator

Power Pulse Modulator A High Performance Versatile Square Pulse Generator Power Pulse Modulator A High Performance Versatile Square Pulse Generator Model: PWM-OCXi v2.2 Type: High Voltage, 9A, 340V, 1.5MHz, Active Protection Features and Specifications * Max current varies with

More information

Training Schedule. Robotic System Design using Arduino Platform

Training Schedule. Robotic System Design using Arduino Platform Training Schedule Robotic System Design using Arduino Platform Session - 1 Embedded System Design Basics : Scope : To introduce Embedded Systems hardware design fundamentals to students. Processor Selection

More information

ISSN: [Kumar* et al.,7(9): September, 2018] Impact Factor: 5.164

ISSN: [Kumar* et al.,7(9): September, 2018] Impact Factor: 5.164 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY A REVIEW ON TRANSFORMER FAULT MONITORING SYSTEM Suman Kumar *1 &Varsha Mehar 2 *1 M.tech Scholar Department of Electrical Engineering

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

AVR Microcontroller based remote controlled embedded system to regulate AC fan or dim AClight with power level, temperature and humidity display.

AVR Microcontroller based remote controlled embedded system to regulate AC fan or dim AClight with power level, temperature and humidity display. AVR Microcontroller based remote controlled embedded system to regulate AC fan or dim AClight with power level, temperature and humidity display. Joyita Tasnia Islam 1, Shibly Sadik 2 1. Engineer, Research

More information

GREEN HOUSE USING IOT

GREEN HOUSE USING IOT Abstract GREEN HOUSE USING IOT L.Praveen Kumar 1, U.V.Arivazhagu 2 ME.,M.B.A.,Ph.D., Department of Computer Science and Engineering Students 1, Professor and Head of Department 2, Kingston Engineering

More information

Improve asset protection and utilization

Improve asset protection and utilization QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause

More information

Real Time Transformer Health Monitoring System using IOT

Real Time Transformer Health Monitoring System using IOT Real Time Transformer Health Monitoring System using IOT D.Sarathkumar, Uvaraj.M, Kabilesh Kumar C V, Kalaiselvi A Assistant Professor, Department of Electrical and Electronics Engineering, 4 Kongu Engineering

More information

Ocean Controls KT-5221 Modbus IO Module

Ocean Controls KT-5221 Modbus IO Module Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,

More information

Modern Electricity Billing System and Fuse Detection Using GSM

Modern Electricity Billing System and Fuse Detection Using GSM Modern Electricity Billing System and Fuse Detection Using GSM Santhya, Sandhya, Saranya, Sowmeya U.G Student, Department of ECE, SNS College of Technology, Coimbatore, Tamilnadu, India Associate Professor,

More information

Power Line Communication Based Fault Monitoring And Control

Power Line Communication Based Fault Monitoring And Control Power Line Communication Based Fault Monitoring And Control Rutika Sanjay Abhang rutikaabhang5@gmail.com Archana Dattatraya Dighe Student of Electrical Engineering achanadighe59@gmail.com Dhanshri Arun

More information

Design and implementation of a programmable remote controlled and monitored irrigation system

Design and implementation of a programmable remote controlled and monitored irrigation system IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 12 (December 2014), V1 PP 25-29 www.iosrjen.org Design and implementation of a programmable remote controlled

More information

AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER

AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER Miss. Manali Ashok Hirave 1, Prof.A.S.Mali 2, Dr. B.T. Salokhe 3 1 Master of Engineering in Electronics, T.K.I.E.T. Warananagar

More information

3 Phase Induction Motor Protection using Numerical Relay

3 Phase Induction Motor Protection using Numerical Relay IJIRST International Journal for Innovative Research in Science & Technology Volume 3 Issue 11 April 2017 ISSN (online): 2349-6010 3 Phase Induction Motor Protection using Numerical Relay Anand B. Gediya

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

AUTOMATIC RESISTOR COLOUR CODING DETECTION & ALLOCATION

AUTOMATIC RESISTOR COLOUR CODING DETECTION & ALLOCATION AUTOMATIC RESISTOR COLOUR CODING DETECTION & ALLOCATION Abin Thomas 1, Arun Babu 2, Prof. Raji A 3 Electronics Engineering, College of Engineering Adoor (India) ABSTRACT In this modern world, the use of

More information

Implementation Of Solid State Relays For Power System Protection

Implementation Of Solid State Relays For Power System Protection Implementation Of Solid State Relays For Power System Protection Nidhi Verma, Kartik Gupta, Sheila Mahapatra ABSTRACT: This paper provides the implementation of solid state relays for enhancement of power

More information

Hydraulic Valve Interface Products

Hydraulic Valve Interface Products Filename: Hydraulic Valve Interface Information.docx Date: 04/02/2014 Version: 2.0 Hydraulic Valve Interface Products Hydraulics provides a wonderful way of generating very large forces to move and control.

More information

Power System Protection Manual

Power System Protection Manual Power System Protection Manual Note: This manual is in the formative stage. Not all the experiments have been covered here though they are operational in the laboratory. When the full manual is ready,

More information

DTMF BASED HOME AUTOMATION SYSTEM USING MICROCONTROLLER WITH PORTABLE POWER SUPPLY

DTMF BASED HOME AUTOMATION SYSTEM USING MICROCONTROLLER WITH PORTABLE POWER SUPPLY DTMF BASED HOME AUTOMATION SYSTEM USING MICROCONTROLLER WITH PORTABLE POWER SUPPLY *Mrs. Ashwini Sawant, **Mr. Sanjay Mirchandani, ***Santoshi Saravanan, ****Shreeparna Sarkar *Assistant Professor, Electronics

More information

Design of LVDT Based Digital Weighing System

Design of LVDT Based Digital Weighing System International Journal of Electronics and Computer Science Engineering 2100 Available Online at www.ijecse.org ISSN- 2277-1956 Pratiksha Sarma 1, P. K. Bordoloi 2 1,2 Department of Applied Electronics and

More information

Methods of secondary short circuit current control in single phase transformers

Methods of secondary short circuit current control in single phase transformers 2015; 1(8): 412-417 ISSN Print: 2394-7500 ISSN Online: 2394-5869 Impact Factor: 5.2 IJAR 2015; 1(8): 412-417 www.allresearchjournal.com Received: 17-05-2015 Accepted: 20-06-2015 Parantap Nandi A/2, Building

More information

[Ahmed, 3(1): January, 2014] ISSN: Impact Factor: 1.852

[Ahmed, 3(1): January, 2014] ISSN: Impact Factor: 1.852 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Microcontroller Based Advanced Triggering Circuit for Converters/Inverters Zameer Ahmad *1, S.N. Singh 2 *1,2 M.Tech Student,

More information

Automatic Lux Level Controller

Automatic Lux Level Controller Automatic Lux Level Controller Chiranjivee Deogade 1, Harshal Ninawe 2, Chanchal Kumar Singh 3, Anup Kutemate 4 Prof. Anusha Yerra 5 1-4 Department of Electrical Engineering, GHRCE, Nagpur, Maharashtra,

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 4.14 International Journal of Advance Engineering and Research Development Volume 3, Issue 2, February -2016 e-issn (O): 2348-4470 p-issn (P): 2348-6406 SIMULATION

More information

Numerical Quadrilateral Distance relay

Numerical Quadrilateral Distance relay Numerical Quadrilateral Distance relay T. M. Yesansure 1, T. G. Arora 2 Dept. of Electrical Engineering, Ramdeobaba College of Engineering and Management, Nagpur, Maharashtra, India 1 Dept. of Electrical

More information

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions 1 Transmission transformers are important links in the bulk power system. They allow transfer of power from generation centers, up to the high-voltage grid, and to bulk electric substations for distribution

More information

An Improved Method for Protection of Three Phase Induction Motor using Microcontroller

An Improved Method for Protection of Three Phase Induction Motor using Microcontroller An Improved Method for Protection of Three Phase Induction Motor using Microcontroller Gagan Garg M.E. Student, EIED Thapar University, Patiala, India gagan_garg1989@yahoo.co.in Abstract A low cost and

More information