1 A Brand Keeping the World Flowing

2 Keeping the World Flowing RELIABILITY IN FLOW CONTROL CRITICAL APPLICATIONS RELIABLE OPERATION WHEN IT MATTERS Assured reliability for critical applications and environments. Whether used 24/7 or infrequently, Rotork products will operate reliably and efficiently when called upon. QUALITY DRIVEN GLOBAL MANUFACTURING Products designed with 60 years of industry and application knowledge. Research and development across all our facilities ensures cutting edge products are available for every application. CTOMER-FOCED SERVICE WORLDWIDE SUPPORT Solving customer challenges and developing new solutions. From initial enquiry through to product installation, longterm after-sales care and Client Support Programmes (CSP). LOW COST OF OWNERSHIP Long-term reliability prolongs service life. Rotork helps to reduce long-term cost of ownership and provides greater efficiency to process and plant. 2

3 Section Page Section Page Section Page Rotork Market Sectors 4 Rotork Instruments 6 Valve Positioner Features Summary 8 Smart Positioner TMP Pneumatic-Pneumatic Positioner YT Electro Pneumatic Positioners YT-1000 / YT Smart Positioners YT-3300 / YT-3350 / YT-3301 / YT YT-3400 / YT YT-2500 / YT-2501 / YT YT YT l/p Converters YT-930 / YT Air Filter Regulators YT-200 / YT-205 / YT-220 / YT Volume Boosters YT-300 / YT-305 / YT-320 / YT-325 / YT-310 / YT Lock Up Valves YT-400 / YT-405 / YT-430 / YT Snap Acting Relays YT-520 / YT-525 / YT-530 / YT Solenoid Valve YT Position Transmitters SPTM-5V 28 SPTM-6V / SPTM-65V 29 Limit Switch Boxes YT YT-870 / YT Examples for Installation 32 Brackets and Levers 34 Appendix A: Equipment Certification Requirements for Hazardous Locations 36 Appendix B: Certifications 38 COMPREHENSIVE PRODUCT RANGE SERVING MULTIPLE INDTRIES Improved efficiency, assured safety and environmental protection. Rotork products and services cover Oil & Gas, Water & Wastewater, Power, Marine, Pharmaceutical, HVAC, Mining, Biomedical, Rail, Pulp & Paper and Food & Beverage industries around the world. MARKET LEADER TECHNICAL INNOVATOR The recognised market leader for 60 years. Our customers have relied upon Rotork for innovative solutions to safely manage the flow of liquids, gases and powders. GLOBAL PRESENCE LOCAL SERVICE Global company with local support. Manufacturing sites, service centres, sales offices and Centres of Excellence throughout the world provide unrivalled customer services and fast delivery. CORPORATE SOCIAL RESPONSIBILITY A responsible business leads to being the best business. We are socially, ethically and environmentally responsible and committed to embedding CSR across all our processes and ways of working. Keeping the World Flowing 3

4 Keeping the World Flowing GLOBAL EXPERIENCE STRATEGIC INDTRIES Active in every industry and market sector around the world. Serving customers and working with partners. Improving efficiency, assuring safety and protecting the environment. 4 INDTRY KNOWLEDGE Our engineering and application knowledgebase, built over 60 years, allows us to provide innovative and reliable solutions for all flow control applications. We work across the globe, servicing a diverse range of markets and critical applications. Our experience of flow control is second to none.

5 OIL & GAS WATER Rotork products are used on upstream, midstream and downstream activities, ranging from offshore production facilities, to refining and processing, to transportation, storage and distribution. Rotork products are used on modern state-of-the-art water treatment and distribution processes, which maximise existing resources such as, desalination plants and water re-use projects, together with conventional water and wastewater plants. Onshore and offshore production Refining and petrochemicals Sludge and sewage treatment Distribution and storage Water treatment, desalination and re-use Pipelines Environmental control LNG liquefaction and regasification Dams, reservoirs and irrigation Unconventional oil and gas POWER OTHER INDTRIES Rotork products are found in traditional power stations, including nuclear power stations where its products are certified for use both inside and outside containment. They are also used for renewable energy generation systems such as thermal solar plants, and emission reduction processes such as flue gas desulphurisation. Marine Pharmaceutical HVAC Mining Biomedical Conventional fuels Rail Nuclear energy Paper & Pulp Concentrating solar power Food & Beverage Geothermal and other renewables Keeping the World Flowing 5

6 Worldwide Industry and Application Experience With nearly 60 years of extensive knowledge and experience, Rotork has provided products and services worldwide for virtually every industrial actuator application. Rotork Instruments are specialist manufacturers of products for flow control, pressure control, flow measurement and pressure measurement. Our solutions are trusted wherever there is a need for high precision and reliability, including pharmaceutical, biomedical, oil & gas and manufacturing industries. We have production facilities throughout the world, complemented by a large network of distribution and support centres. A full listing of our worldwide sales and service network is available on our website at Rotork Instruments offers a range of precision control and valve accessory products through our prestigious brands, including Fairchild, YTC, Soldo, Midland-ACS TM, Bifold, Orange, M&M, Alcon and RI Wireless: Instrument Valves Valve actuation accessories Solenoid valves Piston valves Instrument valves Medium pressure valves Subsea valves and connectors Controllers Valve positioners Rail systems I/P and E/P converters Fire protection Measurement Valve position sensors Transmitters and switches Instrument Pumps Pumps Intensifiers and accumulators Rotork Instruments is proud to offer a diverse range of products which serve many different duties in a wide variety of applications. We also offer a factory customisation service to create one-off units to meet specific needs. 6

7 A valve positioner is a device that adjusts the valve actuator's position based on a control signal and are generally used in control applications because of their precision. Valve positioners are usually mounted on the yolk or top casing of a pneumatic actuator for linear control valves, or near the end of the shaft for rotary control valves. To allow the valve's position to be compared with the position requested by the controller, the positioner can be connected mechanically to the valve stem or valve shaft or detect the movement by noncontact sensing technology. When a control signal differs from the valve actuator's position, the valve positioner changes the pilot pressure to move the actuator until the correct position is reached. Benefits of using a valve positioner on rotary or linear control valves include: Accurately control and fast response to process a valve Control with minimized friction, dead-band, and hysteresis Auto-Tune and Auto-Calibrate through simple and fast setup and configuration Overcome seating frictions Negate flow-induced reactions to higher pressure drops and compensates for internal force imbalances Allow the use various valve characteristics Pneumatic positioners receive pneumatic signals (usually 3-15 psig). The positioner then supplies the valve actuator with the correct air pressure to move the valve to the required position. Pneumatic positioners are intrinsically safe and can provide a large amount of force to close a valve. Electro-pneumatic positioners convert current control signals to equivalent pneumatic signals. It uses a mix of both electricity and air, as implied by the name. Digital or "SMART" positioners use a microprocessor to position the valve actuator while monitoring and recording data. They function very similarly to an electro-pneumatic analogue-type positioners, except the electronic signal conversion is digital rather than analogue. Smart positioners are very accurate, use less air and allow for online digital diagnostics. YTC Positioner technology is based on over 20 years of experience. YTC Positioners and accessories have global recognition for their quality and reliability across all industries and all types of environments. Keeping the World Flowing 7

8 Valve Positioner Features Summary A Brand Type Top Mounted P/P E/P E/P Smart Model TMP-3000 YT-1200 YT-1000 YT-1050 YT-2500 YT-2550 Certification Hardware Diagnostics Feedback Option Comm. Explosion proof Intrinsically safe ATEX/IECEx - - FM/CSA KCs - - EAC - - NEPSI TIIS TS EMC SIL Certified Technology Solenoid Bellows Torque Motor Torque Motor Piezo Piezo Local Buttons LCD Display Single / Double Linear / Rotary Linear Only Feedback NCS Potentiometer Potentiometer Potentiometer Potentiometer Potentiometer Fail Safe Fail Freeze Natural Gas capability IP Rating IP67 IP66 IP66 IP66 IP66 IP66 Enclosure Material PPS Aluminium Aluminium STS316 Aluminium STS316 Mounting Error Supply Air Check Range Error Partial Stroke Test Analogue 4-20 ma Mechanical switches Proximity sensors Transistor switches (soft. type) HART Ver. 5 Ver. 5 Page Notes: 1. Available for rotary version only. In case of hazardous Ex installation area external mount through limit switch box is required. 2. YT-3300/3 and YT-3301, FM available, CSA in progress. 3. NEPSI and EMC only for YT-3300, not for YT

9 Valve Positioner Features Summary YT-2600 YT-2700 YT-3300/3 YT-3301 YT-3350 YT-3400 YT-3450 Smart Piezo Piezo Torque Motor Torque Motor Torque Motor Torque Motor Torque Motor Single Only Potentiometer Potentiometer Potentiometer Potentiometer Potentiometer Potentiometer Potentiometer IP66 IP66 IP66 IP66 IP66 IP66 IP66 Aluminium Aluminium Aluminium Aluminium STS316 Aluminium STS Ver. 5 Ver. 5 Ver. 7 Ver. 7 Ver. 7 Ver. 7 Ver Keeping the World Flowing 9

10 Smart Positioner TMP-3000 Solenoid Technology Design features Vertical mounting. Easy to mount installation. Fail Freeze and Fail Safe function. Enables the valve maintain the last position (Fail Freeze) or move to a pre-determined position (Fail Safe) on the loss of electrical power supply or the pneumatic supply air. LCD display. Backlit alphanumeric digital display for process values and calibration. Feedback signal. 4 to 20 ma output option. Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. Low air consumption level. Almost zero air leakage. Front panel pushbuttons for configuration. Positive acting pushbuttons for field configuration. TMP (1.87) 14.5 (0.57) (7.5) 14.5 (0.57) 138 (5.43) (4.38) Dimensions: mm (Inches ") OUT1 PORT 28 (1.1) OUT2 PORT 4 (1.5 Item Type TMP-3000 Power Supply 24 VDC ± 10% Product Code TMP S - N - G F 9 (3.8 Input Signal 4 to 20 ma, 0 to 5 / 10 V Power Consumption Output Output Characteristics Operating Temp. < 4W 4 to 20 ma Linear, EQ%, Quick Open, User Set (16 points) -10 to 60 C (14 to 140 F) Model TMP-3000 = Smart Positioner Acting Type S = Single D = Double Supply Pressure Air Consumption 0 to 0.7 MPa (0 to 7 bar) 0 LPM Explosion Protection N = Non-Explosion Flow Capacity Filtering Size 20 / 50 LPM 5 micron Conduit & Air Connection G = M16 x G1/8 Acting Type Stroke Single 2 solenoid valves Double 4 solenoid valves 5 to 40 mm Flow Capacity 1 = 20 LPM 2 = 50 LPM Air Connection G1/8 (Ø6 mm tube) Conduit M16 x 1.5 (with screw terminals) Ingress Protection IP67 Output Options 0 = NONE 1 = 4 to 20 ma feedback Body Material Cover Material Weight PPS PC 820 g (1.8 lb) Fail Option F = Fail Freeze S = Fail Safe 10

11 YOUNG TECH Co.,Ltd. Pneumatic-Pneumatic Made in Korea YOUNG TECH Co.,Ltd. Pneumatic-Pneumatic Made in Korea Pneumatic-Pneumatic Positioner YT-1200 Design features Simple zero and span adjustment. Internal hand dials and locking screws for 4 to 20 ma range adjustments. Reverse and Direct Acting Settings. Full and 1/2 split range setting by simple adjustment. High vibration resistant. No resonance between 5 to 200 Hz. Auto / Manual switch. Internal adjustment with lock screw safety. YT-1200 Aluminum Enclosure 35 (1.38) 5 (0.2) (1.38) (2.36) 5 (0.2) (2.36) (1.36) 34.5 (1.36) 2-M8*1.25P 2-M8*1.25P Tap Tap 20 (0.79) 20 (0.79) 28.5 (1.12) 28.5 (1.12) 3 (0.12) 3 (0.12) POSITIONER (6.55) (6.55) 10~ YOUNG TECH Co.,Ltd. 10~ (0.79) (4.21) (0.79) 107 (4.21) 26.5 (1.04) 26.5 (1.04) POSITIONER 30 (1.18) 30 (1.18) YOUNG TECH Co.,Ltd (0.89) 22.5 (0.89) (6.99) (6.99) 80.8 (3.18) 80.8 (3.18) 8-M8*1.25P 8-M8*1.25P Tap Tap Dimensions: mm (Inches ") YT-1200L & YT-1200R Item Type Single Double Input Signal Supply Pressure Stroke Air Connection Gauge Connection Linear Type 0.02 to 0.1 MPa (0.2 to 1 bar) 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm Rotary Type 0 to 90 PT(NPT)1/4 PT(NPT)1/8 Ingress Protection IP66 Operating Temp. (Standard Type) -20 to 70 C (-4 to 158 F) Linearity Linear Type ± 1% F.S. ± 2% F.S. Hysteresis Rotary Type ± 2% F.S. ±1% F.S. Sensitivity Linear Type ± 0.2% F.S. ± 0.5% F.S. Rotary Type ± 0.5% F.S. Repeatability ± 0.5% F.S. Air Consumption 2.5 LPM (sup = 0.14 MPa) Flow Capacity 80 LPM (sup = 0.14 MPa) Material Aluminium Diecasting Weight 1.7 kg (3.1 lb) Product Code Model YT-1200L = Linear Positioner YT-1200R = Rotary Positioner Acting Type S = Single D = Double Lever Type Linear Rotary 1 = 10 to 40 mm 1 = M6 x 34L 2 = 30 to 70 mm 2 = M6 x 63L 3 = 60 to 100 mm 3 = M8 x 34L 4 = 100 to 150 mm 4 = M8 x 63L 5 = NAMUR Orifice Type 1 = Ф1 2 = Ф2 3 = None Air Connection Linear 1 = PT 1/4 2 = NPT 1/4 Operating Temp. S = -20 to 70 C H = -20 to 120 C L = -40 to 70 C YT-1200L Option (Rotary only) 0 = None 1 = Dome Cover 2 = 4 to 20 ma feedback - 5VR 3 = 4 to 20 ma feedback - 6VR 4 = Limit Switch (YT-850) 5 = Limit Switch (YT-870) 6 = 4 to 20 ma feedback + Limit Switch (YT-870) YT-1200R - S S - (0) Keeping the World Flowing 11

12 Electro-Pneumatic Positioners YT-1000 / YT-1050 Design features Simple zero and span adjustment. Internal hand dials and locking screws for adjustments. Internal feedback option. Available on weatherproof model only. Reverse & Direct Acting Settings. Full and 1/2 split range setting by simple adjustment. Auto / Manual switch. Internal adjustment with lock screw safety. High vibration resistant. No resonance between 5 to 200 Hz. YT-1000 Aluminum Enclosure ( (1.53) (1.53) 43.5 (1.71) 43.5 (1.71) (0.9) 23 (0.9) 10~ (3.33) 84.5 (3.33) 167 (6.57) 167 (6.57) 10~ (1.04) (1.3) (1.04) (1.3) (1.79) (1.79) 27 (1.06) 27 (1.06) 2-M8*1.25P 2-M8*1.25P Tap Tap (1.32) (1.32) 4-M8*1.25P 4-M8*1.25P Tap Tap (8.83) (8.83) (4.59) (4.59) 8 (0.31) YT-1000L YT-1000L 33 (1.3) 45 (1.77) 27 (1.06) 23 (0.91) 4-M8*1.25P Tap 4-M8*1.25P Tap (8.83) 00R YT-1050 Dimensions: mm (Inches ") (1.32) 43.5 (1.71) (6.65) 43.5 (1.71) 84.5 (3.33) 23 (0.9) 26.5 (1.04) 27 (1.06) 2-M8*1.25P Tap (1.04) (1.34) 91.8 YT-1050 STS316 Enclosure (1.32) (6.31) 32.5 (1.28) (0.31) (

13 Electro-Pneumatic Positioners YT-1000 / YT-1050 Item Type YT-1000 YT-1050 Input Signal Impedance Supply Pressure Stroke Linear Type 4 to 20 ma DC 250 ± 15 Ω 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm Rotary Type 0 to 90 Air Connection PT(NPT,G)1/4 NPT 1/4 Gauge Connection PT(NPT)1/8 NPT 1/8 Conduit G(PF,NPT)1/2, M20 G 1/2 (PF 1/2) Explosion Protection Type KCs Ex dmb IIB T5/T4 / Ex d IIC T5 IP66 / Ex ia IIB T6 Gb TS Ex db mb IIB T5 Gb X ATEX (II 2 G) Ex dmb IIB T5 IECEx (II2 G) EEx mb IIB T5 CSA (, Zone 1) Ex dm IIB T5 FM XP-S/I/1/CD/T5 Ta=60 C; DIP/II,III/1/EFG/T5 Ta=60 C; Type 4X NEPSI KCs Ex dmb IIB T5 TIIS Ex dmb IIB T5 Ingress Protection IP66 Operating Operating -20 to 70 C (-4 to 158 F) Temp. Explosion -20 to 60 C (-4 to 140 F) Linearity Single ± 1% F.S. Double ± 2% F.S. Hysteresis ±1% F.S. Sensitivity Single ± 0.2% F.S. Double ± 0.5% F.S. Repeatability ± 0.5% F.S. Air Consumption 2.5 LPM (sup = 0.14 MPa) Flow Capacity 80 LPM (sup = 0.14 MPa) Material Aluminium Diecasting Stainless steel 316 Weight YT-1000L: 2.7 kg (6.1 lb) YT-1000R: 2.8 kg (6.2 lb) YT-1050: 5.71 kg (12.6 lb) - Product Code YT R - S - N S (0) Model YT-1000 = Aluminum YT-1050 = STS316 Motion Type L = Linear R = Rotary Acting Type S = Single D = Double Explosion Protection N = Non-Explosion M = ATEX, IECEx, TS, KCs, CSA F = FM (YT-1000 only) C = Ex d KCs, NEPSI (YT-1000 only) I = Exia KCs (YT-1000 only) X = TIIS (YT-1000 only) Lever Type Linear Rotary 1 = 10 to 40 mm 1 = M6 X 34L 2 = 30 to 70 mm 2 = M6 X 63L 3 = 60 to 100 mm 3 = M8 X 34L 4 = 100 to 150 mm 4 = M8 X 63L 5 = NAMUR Orifice Type 1 = Ф1 2 = Ф2 3 = None Conduit & Air Connection YT-1000 YT = G1/2 - PT1/4 2= G1/2 - NPT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Operating Temp. S = -20 to 60 C H = -20 to 120 C L = -40 to 60 C Option 1 YT-1000L YT-1000R 0 = None 0 = None (St'd) 2 = 4 to 20 ma feedback (Smart Type) 1 = Dome Cover 3 = 4 to 20 ma feedback with LCD (Smart Type) Option 2 (YT-1000R only) 0 = None 1 = 4 to 20 ma feedback (Internal - only for non-explosion area protection) 2 = 4 to 20 ma feedback (External) 3 = Limit Switch (Internal - only for non-explosion area protection) 4 = Limit Switch (External) 5 = 4 to 20 ma feedback + Limit Switch (Internal - only for non-explosion area protection) 6 = SPTM + Limit Switch (External) Keeping the World Flowing 13

14 Smart Positioners YT-3300 / YT-3350 / YT-3301 / YT-3303 Torque motor technology with communications Design features Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. LCD display. Alphanumeric digital display for process values and calibration. Partial Stroke Test (PST). Fully adjustable Partial Stroke Test. All functionality can be performed and selected locally, through push buttons, or remotely with communication protocol. Feedback signal. Analogue and Digital feedback signals with 4 to 20 ma, mechanical and proximity switch options (Limit switch options for YT-3300 and YT-3350 models). PID control. Pre-calibrated and user configurable variables via front panel pushbutton menu. Auto / Manual switch. Enables closed-loop automatic valve position control or manual positioning via the A/M switch. The manual mode is useful for troubleshooting, calibration, system testing or as a manual bypass. HART communication. Allows commands, position feedback and diagnostics to be sent digitally over the current loop. Front panel pushbuttons for configuration. 4 robust and positive acting pushbuttons for field configuration. Remote Mounting Option (YT-3301 model). Remote sensor via cable to enable the positioner to be mounted away from extreme temperature. SIL SIL LEVEL 2 YT-3300 Aluminium Enclosure Adapter Type Lever YT-3350 STS316 Enclosure 93.1 (3.67) (4.15) 2 (0.08) 30 (1.18) 26.5 (1.04) 53.5 (2.11) (775) 240 (9.45) (4.24) 10 (0.39) YT-3301 Remote Mounting Option Dimensions: mm (Inches ") Cable Connector 105 (4.13) 74 (2.91) 25 (0.98) YT-3303 Left Side Mounting Option 91.5 (3.60) 16 (0.63) (5.82) (7.98) (4.40) 14

15 Smart Positioners YT-3300 / YT-3350 / YT-3301 / YT-3303 Item Type YT-3300 YT-3303 YT-3350 YT-3301 Input Signal 4 to 20 ma DC Product Code YT L - S - N S - (1) Supply Pressure Linear Type Stroke Rotary Type Impedance 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm 0 to 90 Max ma DC Air Connection PT(NPT,G)1/4 NPT1/4 PT(NPT,G)1/4 Gauge Connection PT(NPT)1/8 NPT1/8 PT(NPT)1/8 Conduit G(PF,NPT)1/2, M20 G(PF)1/2 G(PF,NPT)1/2, M20 Standard Type -30 to 85 C (-22 to 185 F) Low Temp. -40 to 85 C (-40 to 185 F) Operating Type Temp. LCD -30 to 85 C (-22 to 185 F) Explosion Temp. -40 to 60 C (T5) -40 to 40 C (T6) Linearity Hysteresis Sensitivity Repeatability Remote Sensor Air Consumption Flow Capacity Output Characteristics Material - ±0.5% F.S. ±0.5% F.S. ±0.2% F.S. ±0.3% F.S. Below 2 LPM (sup = O.14 MPa) 70 LPM (sup = O.14 MPa) -40 to 120 C (-40 to 248 F) Linear, EQ%, Quick Open user set (18 Point) Aluminium Diecasting Stainless Steel 316 Aluminium Diecasting Ingress Protection IP66 ATEX, IECEx Ex ia IIC T5/T6 Gb, EX iad IIIC T100 C/T85 C Db IP66 NEPSI Ex ia llc T5/T6 Explosion Protection Type Communication (Option) L/S Rating Mechanical Type (Omron) Proximity Type (P&F) KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C CSA Certification in progress FM, Div 1, Groups ABCD, Zone 0 AEx ia IIC I/III, Div 1, Groups EFG, II, III, Div 2, Groups ABCDEFG NEMA Type 4X IP66 AMBIENT TEMP: C (T5) / C (T6) AC 125 V, 3 A DC 30 V, 2 A DC 8.2 V 8.2 ma - - HART (ver.7) AC 125 V, 3 A DC 30 V, 2 A DC 8.2 V 8.2 ma - - Model YT-3300 = Aluminium housing YT-3301 = Aluminium housing with remote sensor YT-3303 = Aluminium housing with right side lever YT-3350 = Stainless steel housing Motion Type L = Linear R = Rotary Acting Type S = Single D = Double Area Protection N = Safe Area I = Intrinsically Safe ATEX, IECEx. NEPSI, KCs A = Intrinsically Safe CSA, FM E = EAC Lever Type Linear Rotary 0 = 10 to 40 mm 1 = M6 x 34L 1 = 20 to 100 mm 2 = M6 x 63L 2 = 90 to 150 mm 3 = M8 x 34L 3 = 16 to 30 mm 4 = M8 x 63L 4 = 16 to 60 mm 5 = NAMUR 5 = 16 to 100 mm roller type 6 = 90 to 150 mm YT-3303, 3301=YT-3400(Same Lever) Conduit & Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Communications 0 = NONE 2 = HART protocol communication Output Options 0 = NONE 1 = 4 to 20 ma feedback 2 = Limit Switch - Mechanical Type (YT-3300 and YT-3350 only) 3 = Limit Switch - Proximity Type (YT-3300 and YT-3350 only) 4 = 4 to 20 ma + Limit Switch - Mechanical Type (YT-3300 and YT-3350 only) 5 = 4 to 20 ma + Limit Switch - Proximity Type (YT-3300 and YT-3350 only) Operating Temp. S = -30 to 85 C L = -40 to 85 C Cable Length (YT-3301 only) Option for YT-3301 only. Standard cable length is 5 m. 1 = 5 m 2 = 10 m 3 = 15 m 4 = 20 m fork type Weight Body Remote Sensor 2 kg (4.4 lb) 5.1 kg (11.2 lb) 2 kg (4.4 lb) kg (2.0 lb) Keeping the World Flowing 15

16 Smart Positioners YT-3400 / YT-3450 Torque motor technology with communications Design features Explosionproof / Flameproof Housing. Global certification for Zone 1 and Division 1 installations. Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. LCD display. Alphanumeric digital display for process values and calibration. Partial Stroke Test (PST). Fully adjustable Partial Stroke Test, with single or double set positions, all functionality can be performed and selected locally, through push buttons, or remotely with communication protocol. Feedback signal. Analogue feedback signals with 4 to 20 ma, mechanical and transistor switch options. Auto / Manual switch. Enables closed-loop automatic valve position control or manual positioning via the Open / Close buttons. The manual mode is useful for troubleshooting, calibration, system testing or as a manual bypass. PID control. Pre-calibrated and user configurable variables via front panel pushbutton menu. HART communication. Allows commands, position feedback and diagnostics to be sent digitally over the current loop. Front panel pushbuttons for configuration. 4 robust and positive acting pushbuttons for field configuration. SIL SIL LEVEL 2 YT-3400 Aluminium Enclosure (4.47) (4.98) (2.06) YT-3450 STS316 Enclosure (8.25) (9.78) (6.03) Dimensions: mm (Inches ") 16

17 Smart Positioners YT-3400 / YT-3450 Item Type YT-3400 YT-3450 Input Signal Supply Pressure Stroke Impedance Linear Type 4 to 20 ma DC 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm Rotary Type 0 to 90 Max ma DC Air Connection PT(NPT,G)1/4 NPT1/4 Gauge Connection PT(NPT)1/8 NPT1/8 Conduit G(PF,NPT)1/2, M20 G(PF)1/2 Operating Temp. Standard Type Low Temp. Type LCD Operating Temp. Explosion Temp. -30 to 85 C (-22 to 185 F) -40 to 85 C (-40 to 185 F) -30 to 85 C (-22 to 185 F) -40 to 80 C (T5) / -40 to 70 C (T6) Linearity ±0.5% F.S. Hysteresis ±0.5% F.S. Sensitivity ±0.2% F.S. Repeatability ±0.3% F.S. Air Consumption Below 2 LPM (sup = O.14 MPa) Flow Capacity 70 LPM (sup = O.14 MPa) Output Characteristics Linear, EQ%, Quick Open user set (18 Point) Material Aluminium Stainless Steel 316 Diecasting Ingress Protection IP66 ATEX, IECEx Ex db IIC T5/T6, Ex tb lllc T85 C/T100 C NEPSI Ex db IIC T5/T6, DIP A21 TA, T5/T6 KCs Ex d IIC T5/T6 IP66 CSA Ex db IIC T5 or T6, Zone 1, AEx db llc T5 or T6, Explosion Protection Type I, Division 1, Groups E, F and G; Ex tb llc T85 C/T100 C AEx tb lllc T85 C/T100 C Product Code Model YT-3400 = Aluminium housing YT-3450 = Stainless steel housing Motion Type L = Linear R = Rotary Acting Type S = Single D = Double Explosion Protection C = ATEX, IECEx, NEPSI, KCs E = EAC A = CSA, FM Lever Type Linear Rotary 1 = 10 to 40 mm 1 = M6 x 34L 2 = 20 to 70 mm 2 = M6 x 63L 3 = 50 to 100 mm 3 = M8 x 34L 4 = 100 to 150 mm 4 = M8 x 63L 5 = NAMUR Conduit & Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Communication 0 = NONE 2 = HART protocol communication Output Options 0 = NONE 1 = 4 to 20 ma feedback 2 = Limit switch 3 = 4 to 20 ma feedback + Limit switch Operating Temp. S = -30 to 85 C L = -40 to 85 C YT L - S - C S FM XP/I/1/ABCD/T6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C I/1/AEx db/iic/t6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C DIP/II, III/1/EFG/T6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C 21/AEx tb/iiic/t85 C Ta= -40 C to +70 C, T100 C Ta= -40 C to +80 C; IP66 Communication (Option) HART (ver.7) Weight 3.4 kg (7.5 lb) 7.0 kg (15.4 lb) Keeping the World Flowing 17

18 20 Smart Positioners YT-2500 / YT-2501 / YT2550 Piezo technology with communications Design features Fail Freeze and Fail Safe function. Enables the valve maintain the last position (Fail Freeze) or move to a pre-determined position (Fail Safe) on the loss of electrical power supply or the pneumatic supply air. Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. LCD display. Alphanumeric digital display for process values and calibration. Low air consumption level. Almost zero air leakage. Feedback signal. Analogue feedback signals with 4 to 20 ma, mechanical and proximity switch options. PD control. Pre-calibrated and user configurable variables via front panel pushbutton menu. HART communication. Allows commands, position feedback and diagnostics to be sent digitally over the current loop. Front panel pushbuttons for configuration. 4 robust and positive acting pushbuttons for field configuration. YT-2500 Aluminium Enclosure 5 (0.2) 45 (1.77) 64.6 (2.54) 97.5 (3.84) YT-2500 SMART POSITIONER (1.18) 30 (1.18) 4-M YT-2550 Stainless Steel Enclosure (4.97) (8.54) 97.5 (3.84) YT-2500 SMART POSITIONER (4.48) 54 (2.13) 12 (0.47) 4-M8*1.25P Tap (8.54) (4.48) YT-2501 Remote Mounting Option 105 (4.13) 74 (2.91) 25 (0.98) 91.5 (3.6) 55 (2.17) YOUNG TECH CO., LTD. Made in Korea 98.6 (3.88) 35 (1.38) (4.74) 13.5 (0.53) CABLE CONNECTOR 4-M5*0.8P Tap 24.3 (0.96) Dimensions: mm (Inches ") 18

19 Smart Positioners YT-2500 / YT-2501 / YT2550 Item Type YT-2500 YT-2550 YT-2501 Input Signal Supply Pressure Stroke Impedance Linear Type 4 to 20 ma DC 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm Rotary Type 0 to 90 Max ma DC Air Connection PT(NPT,G)1/4 NPT1/4 PT(NPT,G)1/4 Gauge Connection PT(NPT)1/8 NPT1/8 PT(NPT)1/8 Conduit Operating Temp. Standard Type LCD Explosion Temp. Remote Sensor Linearity Hysteresis Sensitivity Repeatability Air Fail Freeze Consumption Fail Safe Flow Fail Freeze Capacity Fail Safe Output Characteristics Material G(PF,NPT)1/2, M20 G(PF)1/2-30 to 80 C (-22 to 176 F) G(PF,NPT)1/2, M20-30 to 85 C (-22 to 185 F) -40 to 60 C (T5) -40 to 40 C (T6) -40 to 120 C - (-40 to 248 F) ±0.5% F.S. ±0.5% F.S. ±0.2% F.S. ±0.3% F.S LPM (sup = 0.14 MPa) 6 LPM (sup = 0.14 MPa) 60 LPM (sup = 0.14 MPa) 40 LPM (sup = 0.14 MPa) Linear, EQ%, Quick Open user set (18 Point) Aluminium Diecasting Stainless Steel 316 Aluminium Diecasting Ingress Protection IP66 Explosion Protection Type ATEX, IECEx Ex ia IIC T5/T6 Gb, Ex iad IIC T85 C/T100 C IP6X NEPSI - Ex ia IIC T5/T6 KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C Communication (Option) HART (ver.5) Mechanical AC 125 V, 3 A - Type (Omron) DC 30 V, 2 A L/S Rating Proximity DC 8.2 V 8.2 ma Type (P&F) - Weight Body 1.5 kg (3.3 lb) 2.9 kg (6.4 lb) 1.5 kg (3.3 lb) Linear kg (1.3 lb) Remote sensor Rotary Remote sensor kg (2.0 lb) Product Code Model YT-2500 = Aluminium housing YT-2550 = Stainless steel house YT-2501 = Aluminium housing with remote sensor Motion Type L = Linear R = Rotary Acting Type S = Single D = Double Explosion Protection YT-2500, YT-2550 N = Non-Explosion I = ATEX, IECEx, NEPSI, KCs YT L - S - N S - (1) YT2501 N = Non-Explosion I = ATEX, IECEx, KCs Lever Type Linear Rotary 1 = 10 to 40 mm 1 = M6 x 34L 2 = 20 to 70 mm 2 = M6 x 63L 3 = 50 to 100 mm 3 = M8 x 34L 4 = 100 to 150 mm 4 = M8 x 63L 5 = NAMUR (YT-2501) Conduit & Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Communications 0 = NONE 2 = HART protocol communication Output Options 0 = NONE 1 = 4 to 20 ma feedback 2 = Limit switch - Mechanical Type (YT-2500 and YT-2550 only) 3 = Limit switch - Proximity Type (YT-2500 and YT-2550 only) 4 = 4 to 20 ma feedback + Limit switch - Mechanical Type) (YT-2500 and YT-2550 only) 5 = 4 to 20 ma feedback + Limit switch - Proximity Type (YT-2500 and YT-2550 only) Fail Option F = Fail Freeze S = Fail Safe Cable Length (YT-2501 only) Option for YT-2501 only. Standard cable length is 5 m. 1 = 5 m 2 = 10 m 3 = 15 m 4 = 20 m Keeping the World Flowing 19

20 Unscrew, lift cover, and turn to the direction as arrow indicated. Smart Positioner YT-2600 Piezo technology with communications Design features Fail Freeze and Fail Safe function. Enables the valve maintain the last position (Fail Freeze) or move to a pre-determined position (Fail Safe) on the loss of electrical power supply or the pneumatic supply air. Explosionproof / Flameproof Housing. Global certification for Zone 1 and Division 1 installations Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. LCD display. Alphanumeric digital display for process values and calibration. Low air consumption level. Almost zero air leakage. Feedback signal. Analogue feedback signals with 4 to 20 ma, transistor switch options. PD control. Pre-calibrated and user configurable variables via front panel pushbutton menu. HART communication. Allows commands, position feedback and diagnostics to be sent digitally over the current loop. Front panel pushbuttons for configuration. 4 robust and positive acting pushbuttons for field configuration. YT-2600 Aluminium Exd Positioner 30 (1.18) 121 (4.76) 121 (4.76) 60 (2.36) 55 (2.17) 30 (1.18) (8.09) (9.63) 154 (6.06) Dimensions: mm (Inches ") 5 (0.2) Item Type Input Signal Supply Pressure Stroke Impedance Air Connection Gauge Connection Conduit Operating Temp. Linearity Hysteresis Sensitivity Linear Type YT to 20 ma DC 0.14 to 0.7 MPa (1.4 to 7 bar) 10 to 150 mm Rotary Type 0 to 90 Standard Type LCD Explosion Temp. Max ma DC PT(NPT,G)1/4 PT(NPT)1/8 G(PF,NPT)1/2, M20-30 to 80 C (-22 to 176 F) -30 to 85 C (-22 to 185 F) -40 to 80 C (T5) -40 to 70 C (T6) ±0.5% F.S. ±0.5% F.S. ±0.2% F.S. Repeatability ±0.3% F.S. Air Fail Freeze 0.01 LPM (sup = 0.14 MPa) Consumption Fail Safe 6 LPM (sup = 0.14 MPa) Flow Capacity Fail Freeze 50 LPM (sup = 0.14 MPa) Fail Safe 40 LPM (sup = 0.14 MPa) Output Characteristics Linear, EQ%, Quick Open user set (18 Point) Material Aluminium Diecasting Ingress Protection IP66 ATEX, IECEx Explosion Protection Type Ex db IIC T5/T6, Ex tb IIIC T85 C/T100 C KCs Exd IIC T5/T6 IP66 Communication (Option) HART (ver.5) Weight 3.0 kg (6.61 lb) Product Code Model YT-2600 = Aluminum housing Motion Type L = Linear R = Rotary Acting Type S = Single D = Double Explosion Protection C = ATEX, IECEx, KCs Lever Type Linear Rotary 1 = 10 to 40 mm 1 = M6 x 34L 2 = 20 to 70 mm 2 = M6 x 63L 3 = 50 to 100 mm 3 = M8 x 34L 4 = 100 to 150 mm 4 = M8 x 63L 5 = NAMUR Conduit & Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Communications 0 = NONE 2 = HART protocol communication Output Options 0 = NONE 1 = 4 to 20 ma feedback 2 = Limit switch 3 = 4 to 20 ma feedback + Limit switch Fail Option F = Fail Freeze S = Fail Safe YT L - S - C S 20

21 Smart Positioner YT-2700 Piezo technology single acting Design features Fail Freeze and Fail Safe function. Enables the valve maintain the last position (Fail Freeze) or move to a pre-determined position (Fail Safe) on the loss of electrical power supply or the pneumatic supply air. Auto calibration. Simple menu structure with options to auto calibrate all parameters or zero and end points only. LCD display. Alphanumeric digital display for process values and calibration. Low air consumption level. Almost zero air leakage. Feedback signal. Analogue feedback signals with 4 to 20 ma. PID control. Pre-calibrated and user configurable variables via front panel pushbutton menu. HART communication. Allows commands, position feedback and diagnostics to be sent digitally over the current loop. Front panel pushbuttons for configuration. 4 robust and positive acting pushbuttons for field configuration. YT-2700 Compact Aluminium Positioner 30 (1.18) 7.8 (0.3) 8 (0.31) 47.8 (1.88) 65.4 (5.74) 24 (0.94) (5.7) 78.5 (3.09) 24.3 (0.96) 24 (0.94) Dimensions: mm (Inches ") Item Type Input Signal Supply Pressure YT to 20 ma DC 0.14 to 0.7 MPa (1.4 to 7 bar) Stroke Linear Type 5 to 35 mm Impedance Air Connection Gauge Connection Conduit Operating Temp. Linearity Hysteresis Sensitivity Repeatability Rotary Type 0 to 90 Standard Type LCD Explosion Temp. Max ma DC PT(NPT)1/4 PT(NPT)1/8 G1/2(PF1/2) -30 to 80 C (-22 to 176 F) -30 to 85 C (-22 to 185 F) -40 to 60 C (T5) -40 to 40 C (T6) ±0.5% F.S. ±0.5% F.S. ±0.2% F.S. ±0.3% F.S. Fail Freeze 0.01 LPM (sup = 0.14 MPa) Air Consumption Fail Safe 6 LPM (sup = 0.14 MPa) Flow Capacity Fail Freeze 9 LPM (sup = 0.14 MPa) Fail Safe 40 LPM (sup = 0.14 MPa) Output Characteristics Linear, EQ%, Quick Open user set (18 Point) Material Aluminium Diecasting Ingress Protection IP66 Explosion Protection Type KCs Ex ia IIC T5 Communication (Option) HART (ver.5) Weight 0.82 kg (1.8 lb) Product Code Model YT-2700 = Single acting positioner Motion Type L = Linear R = Rotary Acting Type S = Single Explosion Protection N = Non-Explosion I = KCs Lever Type Linear Rotary 1 = 5 to 35 mm 1 = M6 x 34L 2 = M6 x 63L 3 = M8 x 34L 4 = M8 x 63L 5 = NAMUR Conduit & Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 3 = G1/2 - G1/4 4 = M20 - NPT1/4 5 = NPT1/2 - NPT1/4 Communications 0 = NONE 2 = HART protocol communication Output Options 0 = NONE 1 = 4 to 20 ma feedback Fail Option F = Fail Freeze S = Fail Safe YT L - S - N S Keeping the World Flowing 21

22 IP Converters YT-930 / YT-940 Design features Flameproof Housing (YT-940) for Zone 1 installation. High Accuracy and Sensitivity with pressure sensor. Analogue PID control. High resolution proportional control No effect from mounting orientation. Item Type YT-930 YT-940 Input Signal Standard Output Signal Multirange Standard Supply Minimum Pressure Maximum Explosion Protection Type 4 to 20 ma DC 0.02 to 0.1 MPa (0.2 to 1.0 bar) 0 to 0.12 MPa (0 to 1.2 bar) 0.04 to 0.2 MPa (0.4 to 2.0 bar) 0 to 0.23 MPa (0 to 2.3 bar) 0.13 to 0.16 MPa (1.3 to 1.6 bar) 0.2 bar greater than the maximum calibrated output pressure 0.24 MPa (2.4 bar) ATEX, IECEx FM Ex ia IIC T5/T6 Gb, Division 1 Groups A,B,C,D Ex ia IIIC T100 C/ I, III Division 1 Groups E,F,G T85 C Db Zone 1 AEx d IIC T6 Ta=-40 C to + 75 C, T5 Ta=-40 C to + 85 C, Type 4X, IP66 Zone 21 AEx tb IIIC T85 C Ta=- 40 C to +75 C, T100 C Ta= -40 C to +85 C, Type 4X, IP66 KCs Ex d IIC T5/T6 Below 2 LPM (sup = 0.14 MPa) 70 LPM (sup = 0.14 MPa) -40 to 60 C (T5) / -40 to 40 C (T6) -40 to 85 C (-22 to 185 F) ±0.5% F.S. ±0.5% F.S. ±0.2% F.S. ±0.3% F.S. Air consumption Flow Capacity Explosion Temp. Operating Temp. Linearity Hysteresis Sensitivity Repeatability Air Connection (N)PT 1/4 Conduit G 1.2 (PF 1/2) Ingress Protection IP66 Type 4X, IP66 Impedance Max ma DC Material Aluminium Diecasting Weight 1.6 kg (3.53 lb) 3 kg (6.61 lb) YT-930 Product Code Model YT-930 = Intrinsically Safety Type YT-940 = Flameproof Type Explosion Protection YT-930 N = Non-Explosion I = ATEX, IECEx Output Pressure 1 = 0.02 to 0.1 MPa 2 = 0.00 to 0.12 MPa 3 = 0.04 to 0.2 MPa 4 = 0.00 to 0.23 MPa Conduit - Air Connection 1 = G1/2 - PT1/4 2 = G1/2 - NPT1/4 Operating Temp. L = -40 to 85 C Option 0 = None 1 = Feedback Signal (4 to 20 ma DC) Gauge 0 = None 1 = 0 to 0.2 MPa 2 = 0 to 0.4 MPa YT-940 C = KCs A = FM, CSA YT-940 YT N L Dimensions: mm (Inches ") 17.6 (0.69) 36 (1.42) 29.3 (1.15) 58.6 (2.31) 29.3 (1.15) 3-M8*1.25P 66 (2.6) 2-M8*1.25P 39.8 (1.57) 84.4 (3.32) 30.2 (1.19) (4.91) 22.4 (0.88) 22.2 (0.87) 12.6 (0.5) 44.6 (1.76) 17.6 (0.69) 22.2 (0.87) 27.2 (1.07) 77.2 (3.04) YT (1.1) 2-M8*1.25P 77.6 (3.05) (4.89) (1.98) (6.22) YT (4.56) 52 (2.05) 33.2 (1.31) 8.3 (0.33) 9.3 (0.37) 30.2 (1.19) 42.8 (1.69)

23 Air Filter Regulators YT-200 / YT-205 / YT-220 / YT-225 Design features Stable Output and repeatability. Provides constant control under variable flow rates and supply pressures. Relief flow capability. Discharges pressure if outer pressure is higher than set pressure. Light weight and compact size. Reduces installation costs. 5 micron filter. Protects pneumatic instruments from dirty air. Manual or Auto Draining Option YT-200 YT-205 YT-220 YT-225 YT-200 / YT-205 Flow (LPM) Out Pressure (MPa) Supply: 0.7 MPa Item Type YT-200 YT-220 YT-205 YT-225 Max. Supply Pressure 1.7 MPa (17 bar) Max. Output 0.42 MPa (A Type), 0.84 MPa (B Type) Pressure Air Connection PT (NPT) 1/4 PT (NPT) 1/2 NPT 1/4 NPT 1/2 Gauge Connection PT (NPT) 1/4 PT (NPT) 1/4 NPT 1/4 NPT 1/4 Operating Temp. -20 to 70 ºC (-4 to 158 F) (Standard type) Min. Filtering Size 5 micron Material Aluminium Diecasting Stainless Steel 316 Weight Flow (LPM) 0.6 kg (1.7 lb) 0.86 kg (1.89 lb) YT-220 / YT-225 Flow (LPM) Out Pressure (MPa) Supply: 0.7 MPa Flow (LPM) 1.4 kg (3.0 lb) 2.1 kg (4.6 lb) Product Code Model YT-200 = Aluminum 1/4" YT-205 = Stainless Steel 1/4" YT-220 = Aluminum 1/2" YT-225 = Stainless Steel 1/2" Adjustable Range A = 0 to 0.42 MPa B = 0 to 0.84 MPa Connection Type P = PT N = NPT Gauge 0 = None 1 = 0 to 0.4 MPa 2 = 0 to 1.0 MPa Operating Temp. 1 = -20 to 70 C 2 = -20 to 120 C 3 = -40 to 70 C Option 0 = Manual drain 1 = Auto drain YT A - N (1.22) Dimensions: mm (Inches ") GAUGE PORT SUPPLY PORT 57.2 (2.25) 71.4 (2.81) OUT PORT 61.5 (2.42) DRAIN 63.3 (2.49) 79.1 (3.11) Max. 190 (7.48) GAUGE PORT SUPPLY PORT DRAIN PORT NPT 1/ (2.25) 71.4 (2.81) OUT PORT 17.6 (0.69) 3 (0.12) 85.4 (3.36) (4.50) Max. 213 (8.39) GAUGE PORT SUPPLY PORT DRAIN 72 (2.83) 15.6 (0.61) OUT PORT 110 (4.33) (5.09) Max (9.43) GAUGE PORT SUPPLY PORT DRAIN PORT NPT 1/4 72 (2.83) OUT PORT 15.6 (0.61) 110 (4.33) (6.42) Max. 213 (8.39) YT-200/205 Manual drain YT-200/205 Auto drain YT-220/225 Manual drain YT-220/225 Auto drain Keeping the World Flowing 23

24 BOOSTER RELAY YOUNG TECH CO., LTD. BOOSTER II 2 G c IIC RELAY BOOSTER RELAY YOUNG TECH CO., LTD. II 2 G c IIC YOUNG TECH CO., LTD. MODEL : YT-300 II 2 G c IIC AMBIENT TEMP. : MODEL : YT-300 MODEL : YT-300 AIR CONNECTION : AMBIENT TEMP. : AMBIENT TEMP. : MAX. SUP. PRESS. : AIR 1MPa CONNECTION (10 bar) : AIR CONNECTION : MAX. SIG./OUT PRESS. : MAX. 0.7 MPa SUP. (7 PRESS. bar) : 1MPa (10 bar) MAX. SUP. PRESS. : 1MPa (10 bar) LOT NO. : MAX. SIG./OUT PRESS. : 0.7 MPa (7 bar) MAX. SIG./OUT PRESS. : 0.7 MPa (7 bar) LOT NO. Gimpo-si, Korea : Gimpo-si, Korea LOT NO. : Gimpo-si, Korea YOUNG TECH CO., LTD. YOUNG TECH II 2 CO., G c LTD. IIC II 2 G c IIC YOUNG TECH CO., LTD. II 2 GMODEL c IIC : YT-320 AMBIENT TEMP. MODEL : : YT-320 MODEL : YT-320 AIR CONNECTION AMBIENT : TEMP. : AMBIENT TEMP. : MAX. SUP. PRESS. AIR CONNECTION : 1MPa (10 bar) : AIR CONNECTION : MAX. SIG./OUT PRESS. MAX. : 0.7 SUP. MPa PRESS. (7 bar) : 1MPa (10 bar) MAX. SUP. PRESS. : 1MPa (10 bar) LOT NO. MAX. SIG./OUT PRESS. : 0.7 MPa (7 bar) MAX. SIG./OUT PRESS. : 0.7 MPa (7 bar) LOT : NO. Gimpo-si, : Korea LOT NO. : Gimpo-si, Korea Gimpo-si, Korea Volume Boosters YT-300 / YT-305 / YT-320 / YT-325 / YT-310 / YT-315 Design features Large flow capacity. Specifically designed to be used in conjunction with valve positioners. Optimal sensitivity. Reacts to sudden change in s Fixed deadband. Provides accurate and stable final positioning of the valve. Internal by-pass control. Improves system stability. YT-300 YT-325 YT-315 SIL SIL LEVEL 3 Item Type YT-300 YT-305 YT-320 YT-325 YT-310 YT-315 Max. Supply Pressure 1 MPa (10 bar) Max. Signal / Output Pressure 0.7 MPa (7 bar) Signal/Output Pressure Ratio 1:1 Flow Exhaust Capacity (Cv) Output Supply/Output Connection PT (NPT) 1/4 PT (NPT) 1/2 NPT 3/4 Signal Connection PT (NPT) 1/4 NPT1/4 Linearity ±1% F.S. Operating Temp. -20 to 70 C (-4 to 158 F) (Standard type) Material YT-300, YT-320, YT-310 Aluminium Diecasting YT-305, YT-325, YT-315 Stainless Steel 316 Weight YT-300 YT-320 YT kg (1.1 lb) YT-305 YT-325 YT kg (2.9 lb) 0.76 kg (1.7 lb) 1.9 kg (4.2 lb) 2.3 kg (5.1 lb) 5 kg (11 lb) Product Code YT N - 1 Model YT-300 = Aluminum 1/4" YT-305 = Stainless Steel 1/4" YT-320 = Aluminum 1/2" YT-325 = Stainless Steel 1/2" YT-310 = Aluminum 3/4" YT-315 = Stainless Steel 3/4" Connection Type (YT-305/310/325/315 are only available in NPT connection) P = PT N = NPT Operating Temp. 1 = -20 to 70 C 2 = -20 to 120 C 3 = -40 to 70 C Dimensions: mm (Inches ") ø86 (ø3.39) ø86 (ø3.39) ø86 (ø3.39) SIGNAL PORT SIGNAL SIGNAL PORT PORT Max. 82 (Max. 3.23) Max. 82 (Max. 3.23) 82 (Max. 3.23) ø100 (ø3.94) ø100 (ø3.94) ø100 (ø3.94) SIGNAL PORT SIGNAL SIGNAL PORT PORT SUPPLY SUPPLY PORT 82 PORT 82 OUT OUT PORT PORT SUPPLY SUPPLY PORT PORT 96 SUPPLY PORT 82 OUT PORT 96 SUPPLY PORT 96 OUT PORT OUT OUT PORT PORT SUPPLY PORT SUPPLY SUPPLY PORT PORT (3.23) (3.23) (3.23) (3.78) (3.78) (3.78) BOOSTER RELAY YT-300/305 YT-320/325 YT-310/315 YT-300/305 BOOSTER RELAY BOOSTER RELAY Max. 109 (Max. 4.29) Max. 109 (Max. 4.29) 109 (Max. 4.29) ø121 (ø4.76) ø121 (ø4.76) ø121 (ø4.76) SIGNAL PORT SIGNAL SIGNAL PORT PORT 111 (4.37) (4.37) (4.37) Max. 154 (Max. 6.06) Max. 154 (Max. 6.06) 154 (Max. 6.06) OUTPUT OUTPUT PORT OUTPUT PORT PORT MM MM MM (INCH) (INCH) (INCH) 24

25 Lock-up Valves YT-400 / YT-405 / YT-430 / YT-435 Design features Compact size. No bracket is required. Optimal sensitivity. Detects small variation of the pressure - below 0.01 MPa. Differential Pressure. Differential Pressure of more than 1 bar is required when setting. Symbol YT-400S YT-405D YT-430S YT-435D Single Acting Type Double Acting Type Item Type YT-400 YT-405 YT-430 YT-435 Signal Pressure Max. Supply Pressure Lock-Up Pressure 0.14 to 0.7 MPa (1.4 to 7 bar) Max. 1 MPa (10 bar) Max. 0.7 MPa (7 bar) Differential Pressure Below 0.01 MPa (0.1 bar) Operating Temp. -20 to 70 C (-4 to 158 F) (Standard type) Flow Capacity (Cv) Air Connection PT (NPT) 1/4 NPT 1/4 NPT 3/8 Signal Connection PT (NPT) 1/4 NPT 1/4 NPT 1/4 Material Aluminium Diecasting Stainless Steel 316 Aluminium Diecasting Stainless Steel 316 Weight Single Double 0.45 kg (1.0 lb) 0.7 kg (1.5 lb) 1.3 kg (2.2 lb) 1.5 kg (3.3 lb) 1.3 kg (2.2 lb) 2.3 kg (5.1 lb) 3.3 kg (7.3 lb) 5.8 kg (12.8 lb) Product Code YT S - P - 1 Model YT-400 = Aluminum 1/4" YT-405 = Stainless Steel 1/4" YT-430 = Aluminum 3/8" YT-435 = Stainless Steel 3/8" Acting Type S = Single D = Double Connection Type (YT-405/430/435 are only available in NPT connection) P = PT N = NPT Operating Temp. 1 = -20 to 70 C 2 = -20 to 120 C 3 = -40 to 70 C Dimensions: mm (Inches ") 54 (2.16) BOLT(M8) (4.47) Max. 4t (Max. 0.16) ER'S BRACKET SIGNAL PORT Max. 4t (Max. 0.16) ER'S BRACKET SIGNAL PORT (5.69) IN PORT 1 OUT PORT 1 ER'S BRACKET SIGNAL PORT BOLT(M8) 54 (2.16) (6.81) ER'S BRACKET SIGNAL PORT B PORT 1 A PORT (10.67) IN PORT 2 OUT PORT 2 B PORT A PORT B PORT 2 A PORT 2 IN PORT ø62 (ø2.44) YT-400S, YT-405S (Single Acting) YT-400S/405S OUT PORT ø62 (ø2.44) YT-400D, YT-405D (Double Acting) YT-400, 405 YT YT-400D/405D ø90 (ø3.54) YT-430S, YT-435S (Single Acting) YT-430S/435S YT-430, 435 ø90 (ø3.54) YT- 430D, YT-435D (Double Acting) YT-430D/435D Keeping the World Flowing 25

26 Snap Acting Relays YT-520 / YT-525 / YT-530 / YT-535 Design features Rugged and reliable design. Suitable for all environments. Designed for valve actuation. Changes the direction of the supply air to a fail-safe circuit, or fail freeze in its last known position, on sudden loss of supply air pressure. Differential Pressure. Differential Pressure of more than 1 bar is required when setting. YT-520S YT-525D YT-535S YT-530D Symbol Single Acting Type Double Acting Type Item Type YT-520 YT-525 YT-530 YT-535 Signal Pressure Max. Supply Pressure Operating Temp. Signal Connection In / Output Connection Flow Capacity (Cv) Material Single Weight Double Aluminium Diecasting 0.73 kg (1.8 lb) 1.2 kg (2.7 lb) 0.14 to 0.7 MPa (1.4 to 7 bar) 1 MPa (10 bar) -20 to 70 C (-4 to 158 F) (Standard type) NPT 1/4 NPT 1/4 NPT 3/ Stainless Steel kg (3.7 lb) 3.1 kg (6.3 lb) Aluminium Diecasting 1.3 kg (2.2 lb) 2.3kg (5.1 lb) Stainless Steel kg (7.3 lb) 5.8kg (12.8 lb) Product Code Model YT-520 = Aluminum 1/4" YT-525 = Stainless Steel 1/4" YT-530 = Aluminum 3/8" YT-535 = Stainless Steel 3/8" Acting Type S = Single D = Double Connection Type 2 = NPT Operating Temp. 1 = -20 to 70 C 2 = -20 to 120 C 3 = -40 to 70 C YT S Dimensions: mm (Inches ") 54 (2.13) BOLT(M8) ER'S BRACKET OUT PORT 1 OUT PORT 2 Max. 4t (Max. 0.16) IN PORT 138 (5.43) ER'S BRACKET OUT PORT 1-1 OUT PORT 1-2 OUT PORT 2-1 Max. 4t (Max. 0.16) IN PORT 1 SIGNAL PORT OUT PORT 2-2 IN PORT (8.56) BOLT(M8) ER'S BRACKET SIGNAL PORT B PORT C PORT 54 (2.13) (6.81) A PORT ER'S BRACKET SIGNAL PORT B PORT 1 C PORT 1 B PORT 2 C PORT 2 A PORT (10.67) A PORT 2 ø62 (ø2.44) SIGNAL PORT ø62 (ø2.44) ø90 (ø3.54) ø90 (ø3.54) 26 YT-520S/525S YT-520D/525D YT-530S/535S YT-530D/535D YT-520, 525 YT-530, 535

27 Solenoid Valve YT-720 Design features Balance spool type. No require of backing spring. AC and DC Power options. Interchangeable AC and DC coils. Manual override Options. For maintenance or emergency operation. Rotational Connection. Coil assembly can be rotated. Symbol YT-720S (3-Way) YT-720D (4-Way) IN OUT E1 IN C1 B E2 C2 YT-720S (3-Way) YT-720D (4-Way) Item Type YT-720S YT-720D Max. Supply Pressure 0 to 0.4 MPa 0 to 0.7 MPa 0.1 to 1 MPa 0.2 (Ф3) at 0.4 MPa Output Flow Capacity (Cv) (Ф1.6) at MPa Exhaust N/A AC 220 V 60 ma (11 W) Rating Current AC 110 V 130 ma (12 W) DC 24 V 580 ma (14 W) Frequency 50 to 60 Hz Explosion Protection Type KCs Ex d llc T6 Connection Type PT (NPT) 1/4 Conduit G 1/2 (PF 1/2) Coil Insulation Grade Class F Operating Temp. Operating -20 to 70 C (-4 to 158 F) Explosion -20 to 50 C (-4 to 122 F) Weight O.8 kg (1.8 lb) 1.2 kg (2.6 lb) Product Code Model YT-720 Valve Type S = 3-Way D = 4-Way Connection Type P = PT N = NPT Power Source 1 = AC 110 V 2 = AC 220 V 3 = DC 24 V Pressure 1 = 0 to 0.4 MPa (3-Way) 2 = 0 to 0.7 MPa (3-Way) 3 = 0 to 1.0 MPa (4-Way) YT S - P Dimensions: mm (Inches ") B (5.45) B (5.45) (5.45) (5.45) 139 (5.47) 139 (5.47) 12.5 (0.49) OUT PORT 12.5 (0.49) OUT PORT 55 (2.17) 55 (2.17) IN PORT YT-720S (3-Way) IN PORT YT-720S(3WAY) YT-720S(3WAY) C PORT 1 C PORT 1C PORT 2 C PORT 2 24 (0.94) 30.5 (1.2) (0.94) (8.11) 30.5 (1.2) YT-720D (4-Way) 206 (8.11) 24 (0.94) 30.5 (1.2) 24 (0.94) 30.5 (1.2) 32 (1.26) 45 (1.77) IN PORT 42.5 (1.67) 32 (1.26) 45 (1.77) IN PORT E PORT 1 E PORT (1.67) E PORT 1 2-ø5.5 E PORT Hole 2 Thru. ø10 C.B Dp. 7 2-ø5.5 Hole Thru. ø10 C.B Dp. 7 YT-720D(4WAY) YT-720D(4WAY) 33.5 (1.32) 44 (1.73) 33.5 (1.32) 20.5 (0.81) Keeping the World Flowing (1.73) 20.5 (0.81)

28 Position Transmitter SPTM-5V Design features Convenient wiring: 2 wire type. High accuracy and reliability. Stable Output Simple change for RA v.s. DA action setting. Smart setting. Easy setting of zero and span by pressing the buttons (2 or 5 points setup). SPTM-5V Item Type SPTM-5VL SPTM-5VR Input Type 2 Wire Input Signal 0 to 30 0 to 90 Output Signal 4 to 20 ma DC Load Resistance Vs[v] - 9[v] RL I [ma] Supply Voltage 9 to 28 VDC Noise Range 50 mv p.p Conduit G 1/2 (PF 1/2) Operating Operating -40 to 85 C (-40 to 185 F) Temp. LCD -30 to 85 C (-22 to 185 F) Linearity ±1% F.S. Hysteresis ±0.2% F.S. Sensitivity ±0.2% F.S. Explosion Protection Type Ex ia IIC T5 Ingress Protection IP67 Material Aluminium Diecasting Weight 0.6 kg (1.3 lb) Product Code Model SPTM-5V = Intrinsically Safety Aluminum Motion Type L = Linear R = Rotary Explosion Protection N Lever Type Linear Rotary 1 = 10 to 40 mm 1 = Standard 2 = 20 to 70 mm 2 = NAMUR 3 = 50 to 100 mm 4 = 100 to 150 mm Option 0 = None 1 = With LCD SPTM-5V - L - I (Rotary Type) (Rotary Type) 30 (Linear Type) 30 (Linear Type) 4-M5*0.8P Tap 4-M5*0.8P Tap Dimensions: mm (Inches ") SPTM-5V POSITION TRANSMITTER 55 (2.17) 35 (1.38) (3.88) (1.55) 39.3 (1.55) SPTM-5V POSITION TRANSMITTER 55 (2.17) 35 (1.38) 98.6 (3.88) 74 (2.91) 74 (2.91) 95.5 (3.76) 52.5 (2.07) 52.5 (2.07) 95.5 SPTM-5V (3.76) 55 (2.17) 55 (2.17) 24.3 (0.96) 24.3 (0.96) MM MM (INCH) (INCH) 28

29 Position Transmitters SPTM-6V / SPTM-65V Design features Loop powered 2 wire type. High accuracy and reliability. Stable Output and repeatability. Reverse or Direct acting. Easy to configure options. Smart setting. Easy setting of zero and span by pressing the buttons (2 or 5 points setup). SPTM-6V SPTM-65V Item Type SPTM-6V SPTM-65V Connection Type Input Signal Output Signal Load Resistance Supply Voltage Noise Range 2 Wire Linear 0 to 30 Rotary 0 to 90 4 to 20 ma DC Vs[v] - 9[v] RL I [ma] 9 to 28 VDC 50 mv p.p Conduit PF 1/2 (G 1/2) Operating Operating Temp. Explosion Linearity Hysteresis Sensitivity LCD Explosion Protection Type Ingress Protection Material -40 to 85 C(-40 to 185 F) -40 to 60 C(-40 to 140 F) -30 to 85 C (-22 to 185 F) Aluminium Diecasting ±1% F.S. ±0.2% F.S. ±0.2% F.S. KCs Ex d IIC T6 IP67 Stainless Steel 316 Weight 1.3 kg (2.9 lb) 2.8 kg (6.17 lb) Dimensions: mm (Inches ") Product Code Model SPTM-6V = Flameproof Aluminum SPTM-65V = Flameproof Stainless Steel Motion Type L = Linear R = Rotary Explosion Protection C = Ex d IIC T6 Lever Type Linear Rotary 1 = 10 to 40 mm 1 = Standard 2 = 20 to 70 mm 2 = NAMUR 3 = 50 to 100 mm 4 = 100 to (Rotary mm Type) 30 (Linear Type) 90 (Rotary Type) 30 (Linear Type) SPTM-6V - L - C (4.25) 15 (0.59) 45 (1.77) 5 (0.2) 5 (0.2) 102 (4.02) 108 (4.25) 102 (4.02) 108 SPTM-6V (4.25) 108 (4.25) (4.65) 32 (1.26) 4-M8*1.25P Tap 32 (1.26) (4.65) 29 (1.14) 15 (0.59) 45 (1.77) 60 (2.36) 29 (1.14) 4-M8*1.25P Tap 60 (2.36) SPTM-65V MM (INCH) MM (INCH) Keeping the World Flowing 29

30 YOUNG TECH Co., Ltd. TYPE : MECHANICAL SWITCH / 2 SPDT www. ytc.co.kr Enclosure : IP67 Voltage AC : 250V 3A, 125V 5A DC : 250V 0.2A, 125V 0.4A, 30V 4A, 14V 5A, 8V 5A TYPE : MECHANICAL SWITCH / 2 SPDT Enclosure : IP67 Voltage AC : 250V 3A, 125V 5A DC : 250V 0.2A, 125V 0.4A, 30V 4A, 14V 5A, 8V 5A YOUNG TECH Co., Ltd. www. ytc.co.kr Limit Switch Box YT-850 Design features Visual position indicator. 360 viewing angle. Multiple Output signals. 8 contacts of terminal ports. Universal Compatibility. Suitable for any rotary motion actuator <IS05211>. Easy configuration. Simple adjustment of cam position. Dual conduit entries. Separate connections for power and signal cables. YT-850 Item Type YT-850M YT-850P Switch Type Switch Rating AC Mechanical Switch (2xSPDT) SS5GL (Omron) 250 V 3 A 125 V 5 A SS10GL (Omron) 250 V 10.1 A 125 V 10.1 A Inductive Proximity Sensor PSN17-5DNU (Autonics) DC 250 V 0.2 A, 125 V 0.4 A, 30 V 4 A, 14 V 5 A, 8 V 5 A VDC Ingress Protection IP67 Operating Temp. -20 to 80 C (Standard) Conduit Entry NPT1/2, G1/2, M20 Terminal 8 Points Mounting Bracket NAMUR VDI / VDE 3845, ISO 5211 Material Aluminium Diecasting Weight 880 g (1.94 lb) Dimensions: mm (Inches ") (4.74) (4.74) 97.5 (3.84) LIMIT SWITCH BOX Model : YT (3.84) LIMIT SWITCH BOX Model : YT-850 YT-850 Product Code Model YT-850 = Weatherproof Aluminum Switching Type M = Mechanical Switch (2xSPDT) P = Proximity Type Conduit 1 = 3 = 4 = M20 Bracket Type 0 = None 1 = ST-1 (30*80,H20) 2 = ST-2 (30*80,H30) 3 = ST-3 (30*130,H30) 4 = ST-4 (30*130,H50) 25.5 (1) 64.5 (5.34) 25.5 (1) 64.5 (5.34) (4.74) (4.74) ø4.9 (ø0.19) ø4.9 (ø0.19) 22 (0.87) 17 (0.67) 7 (0.28) 3 (0.12) 22 (0.87) 17 (0.67) 7 (0.28) 3 (0.12) P.C.D ø50 (P.C.D ø1.97) YT M P.C.D ø50 (P.C.D ø1.97) 96.5 (3.8) 4-M6*1.0P Tap 96.5 (3.8) 4-M6*1.0P Tap (1.96) (2.79) (4.74)

31 Limit Switch Boxes YT-870 / YT-875 Design features Visual position indicator. 360 viewing angle. Multiple Output signals. 8 contacts of terminal ports. Universal Compatibility. Suitable for any rotary motion actuator <IS05211>. Easy configuration. Simple adjustment of cam position. Dual conduit entries. Separate connections for power and signal cables. Item Type Switch Type Switch Rating Ingress Protection AC DC Explosion Protection Type YT-870M YT-875M Mechanical Switch (2 x SPDT) SS5GL (Omron) 250 V 5 A 125 V 5 A SS10GL (Omron) 250 V 10.1 A 125 V 10.1 A 250 V 0.2 A, 125 V 0.4 A, 30 V 4 A, 14 V 5 A, 8 V 5 A YT-870P YT-875P Inductive Proximity Sensor PS17-5DNU (Autonics) NJ2-V3-N (P&F) VDC IP VDC YT-870D YT-875D Mechanical Switch (2 x DPDT) DZ-10G-1B (Omron) 125 or 25O VAC 10 A 480 VAC 2 A 125 VDC 0.5 A 250 VDC 0.25 A ATEX, IECEx Ex db IIC T6, Ex tb IIIC T85 C CSA Ex db IIC T6 (5.28), Zone 1, AEx db IIC T6 I, Division 1, Groups E, F and G, Ex tb IIIC T85 C Zone21, AEx tb IIIC T85 C KCs Ex d IIC T6 Operating Temp. -20 to 60 C Conduit Entry NPT3/4 (G3/4, M20, NPT1/2) Terminal 8 Points 136 (5.35) Mounting Bracket Material and Weight 124 (4.88) YT-870 YT-875 NAMUR VDI / VDE 3845, ISO 5211 Aluminium Diecasting: 1.5 kg (3.3 lb) Stainless Steel 316: 3.5 kg (7.7 lb) Product Code Model YT-870 = Flameproof Aluminum YT-875 = Flameproof Stainless Steel Switching Type M = Mechanical Type (2 x SPDT) P = Proximity Type D = Mechanical Type (2 x DPDT) Conduit 1 = NPT 3/4 2 = PF 3/4 (YT-870 only) 3 = M20 (YT-870 only) 4 = NPT 1/2 (YT-870 only) Bracket Type 0 = None 1 = ST-1 (30*80,H20) 2 = ST-2 (30*80,H30) 3 = ST-3 (30*130,H30) 4 = ST-4 (30*130,H50) Option 0 = None 1 = SPTM YT-870 YT-875 YT M Dimensions: mm (Inches ") (2.94) (2.34) (5.28) 136 (5.35) 124 (4.88) 25 (0.98) (5.37) (6.04) 136 (5.35) 124 (4.88) P.C.D ø50 (P.C.D ø1.97) 7 (0.28) 3 (0.12) 4 (0.16) YT-870 / YT875 4-M6*1.0P Tap Keeping the World Flowing (0.98) (5.37) (6.04) 136 (5.35) 124

32 Examples for Installation (Linear Type) Actuator YT-400S YT-300 SPTM-5VL YT-1000L Valve YT-200 YT-1000L (Single type) Application Example Air Tank YT-300 YT-520D Actuator Check Valve YT-300 YT-1000L SPTM-5VL Valve YT-200 YT-1000L (Double type) Application Example 32

33 Examples for Installation (Rotary Type) YT-1000R YT-220 (Auto drain type) Actuator YT-400S YT-300 YT-1000R (Single type) Application Example YT-200 YT-1000R Actuator YT-400D YT-300 YT-300 YT-1000R (Double type) Application Example Keeping the World Flowing 33

34 Brackets and Levers YT-1000R Bracket Series YT-1200R Bracket Series YT-2500R & 2550R & 2600R & 3303R & 3400R & 3450R Bracket Series YT-3300R & 3350R Bracket Series Linear Type Namur Bracket Series 34

35 Brackets and Levers YT-850 & 870 & 875 Bracket Series Lever Series Keeping the World Flowing 35

36 Appendix A: Equipment Certification Requirements for Hazardous Locations ATEX & IECEx Typical ATEX & IECEx Marking [*ATEX only] II 2 G ccs Aus Typical North American Marking (CSA), Division 1, Groups A,B,C,D T4 *Complies with European Directives *Notified Body Number *Specific Marking for Explosion Protection *Equipment Group *Equipment Category *Environment Hazard Class Area Classification Gas Group I, Division 1, Groups E,F,G Temperature Class Ex db IIC T4 Gb Hazard Class Area Classification Dust Group Explosion Protection Type of Protection Gas Group Temperature Class (T1-T6) Equipment Protection Level (EPL), Zone 0, AEx ia IIC T4 Ex tb IIIC T135 C Db Explosion Protection Type of Protection Dust Type Temperature Class ( C) Equipment Protection Level Hazard Class Area Classification Approved to Standards Protection Concept Code Gas Group Temperature Class Protection Concepts Type of Protection Symbol Typical IEC EPL Typical Zone(s) IEC Standard Electrical Equipment for Gases, Vapours and Mists (G) General Requirements IEC Optical Radiation Increased Safety Op pr Op sh Op is eb ec Gb Ga Ga Gb Gc 1, 2 0, 1, 2 0, 1, 2 1, 2 2 IEC IEC Type n (non-sparking) na Gc 2 IEC Flameproof da db dc Ga Gb Gc 0, 1, 2 1, 2 2 IEC Basic Concept of Protection Protection against ignitions from optical radiation No arcs, sparks or hot surfaces. Enclosure IP54 or better Contain the explosion, quench the flame Type n (enclosed break) nc Gc 2 IEC Quartz / Sand Filled q Gb 1, 2 IEC Quench the flame Intrinsic Safety Type n (sealing & hermetic sealing) ia ib ic Ga Gb Gc 0, 1, 2 1, 2 2 IEC nc Gc 2 IEC Limit the energy of sparks and surface temperatures Type n (restricted breathing) nr Gc 2 IEC Keep the flammable gas out Encapsulation ma mb mc Ga Gb Gc 0, 1, 2 1, 2 2 IEC Electrical Equipment for Combustible Dusts (D) General Requirements IEC Optical Radiation Enclosure Intrinsic Safety Encapsulation General Requirements Op pr Op sh Op is ta tb tc ia ib ic ma mb mc Db Da Da Da Db Dc Da Db Dc Da Db Dc 21, 22 Protection against 20, 21, 22 IEC ignitions from 20, 21, 22 optical radiation 20, 21, 22 21, , 21, 22 21, , 21, 22 21, IEC IEC IEC Electrical Equipment for Combustible Dusts (D) EN h Ga, Gb, Gc Da, Db, Dc 0, 1, 2 IEC , 21, 22 Standard protection for dusts, rugged tight enclosure Limit the energy of sparks and surface temperatures Protection by encapsulation of incendive parts Low potential energy Flow Restricted Enclosure Flameproof Enclosure fr d EN EN Relies on tight seals,closely matched joints and tough enclosures to restrict the breathing of the enclosure c - 0, 1, 2 20, 21, 22 EN Ignition hazards eliminated by Constructional Safety h Ga, Gb, Gc Da, Db, Dc 0, 1, 2 IEC , 21, 22 good engineering methods Protection Concepts Type of Protection General Requirements Code Country Class Division / Zone Standard Electrical Equipment for Flammable Gas, Vapors and Mists - AEx Ex Increased AEx e Safety Ex e (NI) Non-Incendive (NI) AEx na Non-Sparking Ex na (XP) Explosion Proof (XP) AEx d Flameproof AEx d Ex d AEx nc Enclosed Break Ex nc (IS) (IS) AEx ia Intrinsic Safety AEx ib EX ia Ex ib AEx nc Limited Energy Ex nl Restricted AEx nr Breathing Ex nr Encapsulated General Requirements AEx ma AEx m Ex m AEx mb Ex CA CA CA CA CA CA CA CA CA CA CA CA CA CA Division 1 & 2 Division 1 & 2 Zone 1 & 2 Zone 1 & 2 Zone 1 Zone 1 Division 2 Division 2 Zone 2 Zone 2 Division 1 Division 1 Zone 1 Zone 1 Zone 1 Zone 2 Zone 2 Division 1 Division 1 Zone 0 Zone 1 Zone 0 Zone 1 Zone 2 Zone 2 Zone 2 Zone 2 Zone 0 Zone 1 Zone 1 Zone 1 FM ISA CSA ISA CSA C22.2 No ISA / FM 3611 C22.2 No. 213 ISA CSA C22.2 No UL 1203 / FM 3615 C22.2 No. 30 ISA UL 1203 / FM 3615 CSA ISA Basic Concept of Protection No arcs, sparks or hot surfaces Contain the explosion and extinguish the flame CSA C22.2 No UL 913 / FM 3610 C22.2 No. 157 ISA / FM 3610 Limit energy ISA / FM 3610 of sparks and CSA C22.2 No surface CSA C22.2 No temperature ISA CSA C22.2 No ISA CSA C22.2 No ISA ISA CSA C22.2 No ISA Electrical Equipment for Flammable Gas, Vapors and Mists - CA CA Dust Ignition - Proof CA Dust Protected - CA AEx ta AEx tb Protection by AEx tc Enclosure Ex ta CA Ex tb CA Ex tc CA Encapsulation AEx mad AEx mbd (IS) (IS) CA Intrinsic Safety AEx iad AEx ibd (IS) (IS) CA I I II II - Division 1 & 2 Division 1 & 2 Division 1 & 2 Division 1 & 2 Zone 20, 21, 22 I I Division 1 Division 1 I Division 2 I Division 2 I Zone 20 I Zone 21 I Zone 22 I Zone 20 I Zone 21 I Zone 22 - Zone 20 - Zone 21 I I - - II II Division 1 Division 1 Zone 20 Zone 21 Division 1 Division 1 FM 3600 CSA C22.2 No.0 FM 3600 CSA C22.2 No.0 ISA UL 1203 / FM 3616 CSA C22.2 No. 25 ISA / FM 3611 CSA C22.2 No. 25 ISA ISA ISA CSA C22.2 No CSA C22.2 No CSA C22.2 No ISA ISA UL 913 / FM 3610 CSA C22.2 No. 157 ISA ISA UL 913 / FM 3610 CSA C22.2 No. 157 Keep flammable gas out Keep combustible dust out Limit energy of sparks and surface temperature Control of Ignition Source b - - EN Control equipment Ga, Gb, Gc 0, 1, 2 fitted to detect h IEC Da, Db, Dc 20, 21, 22 malfunctions 36

37 Appendix A: Equipment Certification Requirements for Hazardous Locations ATEX & IECEx Certificate Number SIRA 13 ATEX 1234 Name of Notified Body performing EC-type examination Year of Certification Reference to ATEX 95 Directive IECEx CSA Serial Number Temperature Classification Classification of maximum surface temperatures for Group II Electronic Equipment (T Class). IIA T1 Ammonia 630 IIC T1 Hydrogen 560 IIA T1 Methane 537 IIA T1 Propane 470 C Name of Notified Body performing EC-type examination Name of Body Performing IECEx Certification Year of Certification Serial Number IIB T2 Ethylene 425 IIA T2 Butane 372 IIC T2 Acetylene 305 Suffixes: U component certification X special conditions for safe use apply Apparatus Groups [ATEX and IECEx] Group Environment Location Typical Substance I IIA IIB IIC IIIA IIIB IIIC Gases, Vapours Combustible Dusts Coal Mining Surface and other locations Surface and other locations Methane (Fire damp) Acetic acid, Acetone, Ammonia, Butane, Cyclohexane, Gasoline (petrol), Kerosene, Methane (natural gas) (nonmining), Methanol (methyl alcohol), Propane, Propan-2-ol (iso-propyl alcohol), Toluene, Xylene Di-ethyl ether, Ethylene, Methyl ethyl ketone (MEK), Propan-1-ol (n-propyl alcohol), Ethanol (ethyl alcohol) Acetylene, Hydrogen, Carbon disulphide Combustible flyings Non-conductive Conductive Apparatus Groups ( / CAN) Substance Hazard Class NEC 500 NEC 505 Acetylene Group A Hydrogen Group B IIC Ethylene Group C IIB Flammable Gases Propane Group D IIA Methane (mining) Group D - Combustible Metal Dusts Combustible Carbonaceous Dusts Combustible Dusts not in Group E or F (Flour, Grain, Wood, Plastics, Chemicals) Combustible Fibers and Flyings I Combustible Dusts II Fibers and Flyings Classification of Divisions and Zones Group E - Group F - Group G Type of Area NEC and CEC* ATEX and IEC Definitions Continuous hazard Intermittent hazard Hazard under abnormal conditions Division 1 Division 1 Division 2 Zone 0 / Zone 20 Cat 1 Zone 1 / Zone 21 Cat 2 Zone 2 / Zone 22 Cat 3 IIC A place in which an explosive atmosphere is continuously present A place in which an explosive atmosphere is likely to occur in normal operation A place in which an explosive atmosphere is not likely to occur in normal operation, but may occur for short periods * On occasion the ATEX and IEC Zones may be used in the corresponding NEC and CEC system IIA T3 Cyclohexane 259 IIA T3 Kerosene 210 IIB T4 Di-ethyl Ether 160 IIC T6 Carbon Disulphide 95 Dusts Typical Ignition Temperatures ( C) Dusts Cloud Layer Aluminium Coal dust (lignite) Flour Grain dust Methyl cellulose Phenolic resin Polythene PVC Soot Starch Sugar 590 C 380 C 490 C 510 C 420 C 530 C 420 C 700 C 810 C 460 C 490 C Ingress Protection Codes >450 C 225 C 340 C 300 C 320 C >450 C (melts) C >450 C 570 C 435 C 460 C First Number (protect from solid bodies) Second Number (protect from water) 0 No protection 0 No protection 1 Objects > 50mm 1 Vertical drip 2 Objects > 12.5mm 2 Angled drip 3 Objects > 2.5mm 3 Spraying 4 Objects > 1.0mm 4 Splashing 5 Dust-protected 5 Jetting 6 Dust-tight 6 Powerful jetting 7 Temporary immersion 8 Continuous immersion Enclosure Type Ratings (NEMA / CSA / UL) Type Area Brief Definition 1 Indoor General purpose 2 Indoor Protection against angled dripping water 3, 3R, 3S Indoor / Outdoor Protection against rain, snow 4, 4X Indoor / Outdoor Protection against rain, snow, hose directed water 5 Indoor Protection against angled dripping water, dust, fibers, flyings 6 Indoor / Outdoor Protection against temporary submersion 6P Indoor / Outdoor Protection against prolonged submersion 12, 12K Indoor Protection against circulating dust, fibers, flyings 13 Indoor Protection against circulating dust, fibers, flyings, seepage Keeping the World Flowing 37

38 Appendix B: Certifications Product Type Model Number Cert. Type Rating YT-1000 / 1050 ATEX II 2G Ex db mb IIB T5 Gb IECEx Ex db mb IIB T5 Gb FM XP-S/I/1/CD/T5 Ta=60 C; DIP/II,III/1/EFG/T5 Ta=60 C; Type 4X CSA (, Zone 1) Ex dm IIB T5 EIectro-Pneumatic NEPSI Ex dmb IIC T6 Gb / Ex ia IIC T6 Positioner YT-1000 TIIS Ex dmb IIB T5 TS Ex db mb IIB T5 Gb X KCs Ex dmb IIB T5/T4 Ex d IIC T5 IP66 Ex ia IIB T6 Gb YT-1050 KCs Ex dmb IIB T5 YT-3300 / 3350 /3303 / 3301 / 3400 / 3450 SIL SIL2/SIL3 YT-3300 / 3350 / 3303 / 3301 ATEX Ex ia IIC T5/T6 Gb, EX iad IIIC T100 C/T85 C Db IP66 IECEx Ex ia IIC T5/T6 Gb, EX iad IIIC T100 C/T85 C Db IP66 YT-3300 / 3350 / 3303 / 3301 FM, Div 1, Groups ABCD, Zone 0 AEx ia IIC I/III, Div 1, Groups EFG, II, III, Div 2, Groups ABCDEFG NEMA Type 4 IP66 YT-3300 / 3350 / 3303 / 3301 CSA, Division 1, Groups A, B, C, and/or D T5/T6, Division 2, Groups A, B, C, and/or D T5/T6 I, Division 1, Groups E, F, and/or G T100 C/T85 C I, Division 2, Groups E, F, and/or G T100 C/T85 C II Ex ia IIC T5/T6 Ga Ex tb IIIC T100 C/T85 C Db YT-3300 NEPSI Ex ia IIC T5/T6 YT-3300 / YT-3350 / YT-3303 / YT-3301 KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C ATEX Ex db IIC T5/T6, Ex tb IIIC T85 C/T100 C IECEx Ex db IIC T5/T6, Ex tb IIIC T85 C/T100 C XP/I/1/ABCD/T6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C I/1/AEx db/iic/t6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C FM Smart Positioner DIP/II, III/1/EFG/T6 Ta= -40 C to +70 C, T5 Ta= -40 C to +80 C YT-3400 / /AEx tb/iiic/t85 C Ta= -40 C to +70 C, T100 C Ta= -40 C to +80 C; IP66 Ex db IIC T5 or T6 CSA, Zone 1, AEx db IIC T5 or T6, I, Division 1, Groups E, F and G; Ex tb IIC T85 C/T100 C AEx tb IIIC T85 C/T100 C NEPSI Ex db IIC T5/ T6, DIP A21 TA, T5/T6 YT-3400 KCs Ex d IIC T5/T6 IP66 YT-3450 KCs Ex d IIC T5/T6, Ex tb IIIC T85 C/T100 C YT-2500 / 2550 / 2501 ATEX Ex ia IIC T5/T6 Gb, Ex iad IIC T85 C/T100 C IP6X IECEx Ex ia IIC T5/T6 Gb, Ex iad IIC T85 C/T100 C IP6X YT-2500 NEPSI Ex ia IIC T5/T6 KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C YT-2550 KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C YT-2501 KCs Ex ia IIC T5/T6, EX iad IIIC T100 C/T85 C ATEX Ex db IIC T5/T6, Ex tb IIIC T85 C/T100 C YT-2600 IECEx Ex db IIC T5/T6, Ex tb IIIC T85 C/T100 C KCs Ex d IIC T5/T6 IP66 YT-2700 KCs Ex ia IICT5 YT-930 ATEX Ex ia IIC T5/T6 Gb, Ex ia IIIC T100 C/T85 C Db IECEx Ex ia IIC T5/T6 Gb, Ex ia IIIC T100 C/T85 C Db Division 1, Groups A, B, C, D; T6 Ta= -40 C to +75 C, T5 Ta= -40 C to +85 C; Type4X, IP66 FM I, III Division1, Groups E, F, G;T6 Ta=-40 C to+75 C, T5 Ta=-40 C to+85 C; Type4X, IP66 IP Converter, Zone 1, AEx d IIC T6 Ta= -40 C to + 75 C, T5 Ta= -40 C to +85 C, Type 4X, IP66 YT-940 Zone 21 AEx tb IIIC T85 C Ta= -40 C to +75 C, T100 C Ta= -40 C to +85 C, Type 4X, IP66 CSA Ex db IIC T5 or T6 Ex tb IIC T85'C/T100'C, IP66 KCs Ex d IIC T5/T6 Solenoid Valve YT-720 KCs Ex d IIC T6 Position Transmitter Limit Switch SPTM-6V KCs Ex d IIC T6 IP67 SPTM-65V KCs Ex d IIC T6 IP67 ATEX Ex db IIC T6, Ex tb IIIC T85 C IECEx Ex db IIC T6, Ex tb IIIC T85 C YT-870 / 875 Ex db IIC T6 CSA, Zone 1, AEx db IIC T6 I, Division 1, Groups: E, F and G, Ex tb IIIC T85 C Zone 21, AEx tb IIIC T85 C YT-870 KCs Ex d IIC T6 YT-875 KCs Ex d IIC T6 Volume Booster YT-300 / 305 / 320 / 325 / 310 / 315 SIL SIL3 38

39 Keeping the World Flowing 39

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL. PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic

More information

Young Tech Co., Ltd.

Young Tech Co., Ltd. Smart Positioner Electro-Pneumatic Positioner Pneumatic-Pneumatic Positioner Volume Booster Air Filter Regulator Lock Up Valve Snap Acting Relay Solenoid Valve Electro Position Transmitter Young Tech Co.,

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

Young Tech Co., Ltd.

Young Tech Co., Ltd. Smart Positioner Electro-Pneumatic Positioner Pneumatic-Pneumatic Positioner Volume Booster Air Filter Regulator Lock Up Valve Snap Acting Relay Solenoid Valve Electro Position Transmitter Limit Switch

More information

Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments

Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS3 Linear / Rotary Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments Flameproof IECEx / ATEX

More information

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual

INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES. ESL & ESR Series. Installation & Maintenance Manual INSTRUCTION MANUAL SMART POSITIONER ESL & ESR SERIES 1 September 26, 2005 - I N D E X - 1. Features.... P.3 11-6] Sub-Parameters... P.14 2. Specifications 11-6-1] Changing Input Signal. 3. Principle of

More information

Fisher 646 Electro-Pneumatic Transducers

Fisher 646 Electro-Pneumatic Transducers Product Bulletin D101374X012 646 Transducers Fisher 646 Electro-Pneumatic Transducers Fisher 646 electro-pneumatic transducers, shown in figure 1, use a patented converter module that converts a 4 to 20

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES M/SSL/SSR/E 01 2009 INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES 1 - I N D E X - 1. Features.... P.3 11-6] Sub-Parameters... 2. Specifications 11-6-1] Changing Input Signal. P.15 3. Principle

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Rotary Valve Positioners

Rotary Valve Positioners Rotary Valve Positioners 6 PNY-SERIES PNY-Series Pneumatic Positioners Available Options Item Type PNY Series 3 15 psi 20 100 psi Air Connection PT (NPT) 1/4 Gage Connection PT (NPT) 1/8 PNY01 PNY02 PNY03

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology SoCLEAN Sanitary and Electropolished Finish Inherent Accuracy ±1 mm No Scheduled Maintenance or Recalibration Hazardous

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

All TXI7850 products are ROHS compliant.

All TXI7850 products are ROHS compliant. Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

POSITIONERS. Positioners. K10 Electro-Pneumatic Positioner " K10 Electro-Pneumatic Positioner w/ Keypad & Remote Infrared AutoCal Calibration

POSITIONERS. Positioners. K10 Electro-Pneumatic Positioner  K10 Electro-Pneumatic Positioner w/ Keypad & Remote Infrared AutoCal Calibration Positioners K1 Electro-Pneumatic Positioner " K1 Electro-Pneumatic Positioner w/ Keypad & Remote Infrared AutoCal Calibration ICoT Smart Positioners " Design Features " ICoT 41 Electro-Pneumatic Positioner

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

Submersible pressure sensor For superior applications Model LF-1

Submersible pressure sensor For superior applications Model LF-1 Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology RefineME 4-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration

More information

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products Data sheet DS/AT100S-EN Rev. N AT100S Magnetostrictive Level Transmitter Sanitary magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* High Accuracy:.01% of Full Scale Superior

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

AT200 External Mount Magnetostrictive Level Transmitter

AT200 External Mount Magnetostrictive Level Transmitter Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up. Model L2610 Instrumentation designed with the user in mind. NULL-KOTE Self-Diagnostic Analog Level Transmitter Electronic, RF Impedance sensing, with the innovative NULL-KOTE system, which ignores product

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

LA-5000 SERIES LINEAR VALVE ACTUATORS

LA-5000 SERIES LINEAR VALVE ACTUATORS LA-5000 SERIES LINEAR VALVE ACTUATORS GENERAL DESCRIPTION The LA-5000 Series are bi-directional, linear actuators internally geared to produce up to 6,500 lbs. (28,913 N) of thrust, and offer continuous

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU Level probe Features Assembly Device for hydrostatic pressure measurement in liquids High resistance to overload High-precision, robust ceramic measuring cell with longterm stability Simultaneous level

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Level Plus. CHAMBERED Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. CHAMBERED Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology CHAMBERED Designed for Magnetic Level Gauge (MLG) No Scheduled Maintenance or Recalibration Hazardous Area Certified MEASURING

More information

Baymaster LED Luminaire High Bay for Hazardous Locations

Baymaster LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Flow rate Indicator / Totalizer

Flow rate Indicator / Totalizer Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries. SmartLine Non-Contact Radar Level Meter Technical Datasheet 34-VF-03-19 September 2009 Specification The Universal Radar Solution The SmartLine Non-Contact Radar Level Meter (FMCW) is for level measurement

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Accutech DP20. Wireless differential pressure field unit

Accutech DP20. Wireless differential pressure field unit Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional

More information

Accutech GP10. Wireless gauge pressure field unit

Accutech GP10. Wireless gauge pressure field unit Accutech GP10 Wireless gauge pressure field unit 1 The Accutech GP10 wireless gauge pressure field unit provides pressure data in a variety of ranges from 250 to 10000 PSIG. With its integrated and highly

More information

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer Model T7800 Series Electro-Pneumatic I/P, E/P Transducer General Information The T7800 Series Transducers provide maximum versatility for precision applications. Field Reversible Feature provides output

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx) Heading Product Name A Higher Level of Performance Data Sheet HAWK Magnetostrictive Level Transmitter For more information, please visit > www.hawkmeasure.com Model HLT Transmitter with Analog Output and

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

FDY PC-Programmable Frequency-to-DC Transmitter with Display

FDY PC-Programmable Frequency-to-DC Transmitter with Display PC-Programmable -to-dc March 2017 Description The PC-Programmable -to-dc monitors frequency, period, high or low pulse width, and contact closure signals. It converts the input signal to a proportional,

More information