CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

Size: px
Start display at page:

Download "CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018."

Transcription

1 July 2018, Revision: Issue Page 1 of 16 CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER July 2018 Revision: Issue Corning Optical Communications reserves the right to update this specification without prior notification. 1.0 FlexNAP Systems Distribution Trunk, Tap, Tether: General The FlexNAP Distribution Systems for outside plant consists of a factory-tested distribution trunk cable, tether attachment points, tether assemblies, and multiport terminals that allow for a quick, reliable installation. The FlexNAP Distribution System utilizes standard optical fiber cables upon which tether attachment points (TAPs) are preinstalled at customer-specified locations along the length of the cable. The cable and tether attachment points are tested and shipped as a complete system. FlexNAP TAP (Tether Attachment Point) FlexNAP Distribution Trunk Cable Figure 1: FlexNAP Distribution System Trunk components for outside plant 1.1 The FlexNAP Distribution System is designed to meet the applicable performance criteria of GR-3122 and S Fiber Characteristics 2.1 Detailed information on the fiber types available for this cable design can be found in the following documents: Dispersion Un-shifted and Non-zero Dispersion Shifted Singlemode Fiber: Generic Specification F1, Generic Specification for Single-mode Optical Fiber in Loose Tube and Ribbon Cables. 3.0 Distribution Trunk Cable Construction 3.1 Optical fibers shall be placed inside a loose buffer tube. The nominal outer diameter of the buffer tube shall be 2.5 mm.

2 March 2018, Revision: Issue Page 2 of Each buffer tube shall contain up to 12 fibers. 3.3 The fibers shall not adhere to the inside of the buffer tube. 3.4 Each fiber shall be distinguishable by means of color coding in accordance with TIA/EIA-598-B, "Optical Fiber Cable Color Coding." 3.5 The fibers shall be colored with ultraviolet (UV) curable inks. 3.6 Buffer tubes containing fibers shall be color coded with distinct and recognizable colors in accordance with TIA/EIA-598-B, "Optical Fiber Cable Color Coding." Buffer tube colored stripes shall be inlaid in the tube by means of co-extrusion when required. The nominal stripe width shall be 1 mm. 3.7 For cables containing more than 12 buffer tubes, standard colors are used for tubes 1 through 12 and stripes are used to denote tubes 13 through 24. The color sequence applies to tubes containing fibers only, and shall begin with the first tube. If fillers are required, they shall be placed in the inner layer of the cable. The tube color sequence shall start from the inside layer and progress outward. 3.8 In buffer tubes containing multiple fibers, the colors shall be stable across the specified storage and operating temperature range and shall not be subject to fading or smearing onto each other. Colors shall not cause fibers to stick together. 3.9 The buffer tubes shall be resistant to external forces and shall meet the buffer tube cold bend and shrinkback requirements of 7 CFR Fillers may be included in the cable core to lend symmetry to the cable cross-section where needed. Fillers shall be placed so that they do not interrupt the consecutive positioning of the buffer tubes. In dual layer cables, any fillers shall be placed in the inner layer. Fillers shall be nominally 2.5 mm in outer diameter The central member shall consist of a dielectric, glass reinforced plastic (GRP) rod (optional steel central member). The purpose of the central member is to provide tensile strength and prevent buckling. The central member shall be overcoated with a thermoplastic when required to achieve dimensional sizing to accommodate buffer tubes/fillers For gel-filled constructions each buffer tube shall be filled with either a non-hygroscopic, non-nutritive to fungus, electrically non-conductive, homogenous gel. The gel shall be free from dirt and foreign matter. The gel shall be readily removable with conventional nontoxic solvents. For gelfree construction each buffer tube shall contain water blocking material embedded in the inside wall of the buffer tube for water-blocking protection. The water blocking material shall be non-nutritive to fungus, electrically Corning Restricted

3 July 2018, Revision: Issue Page 3 of 16 non-conductive, and homogeneous. It shall also be free from dirt or foreign matter. This material will preclude the need for other water-blocking materials such as gels, yarns, foams, or tapes; the buffer-tube shall be gel-free The optical fibers shall not require cleaning before placement into a splice tray or fan-out kit Buffer tubes shall be stranded around the dielectric central member using the reverse oscillation, or "S-Z", stranding process Water swellable yarn(s) shall be applied longitudinally along the central member during stranding. Water blocking elements shall be applied uniformly throughout the buffer tube Two polyester yarn binders shall be applied contrahelically with sufficient tension to secure each buffer tube layer to the dielectric central member without crushing the buffer tubes. The binders shall be non-hygroscopic, non-wicking, and dielectric with low shrinkage For single layer cables, a water swellable tape shall be applied longitudinally around the outside of the stranded tubes/fillers. The water swellable tape shall be non-nutritive to fungus, electrically non-conductive, and homogenous. It shall also be free from dirt and foreign matter For dual layer cables, a second (outer) layer of buffer tubes shall be stranded over the original core to form a two layer core. A water swellable tape shall be applied longitudinally over both the inner and outer layer. The water swellable tape shall be non-nutritive to fungus, electrically nonconductive, and homogenous. It shall also be free from dirt and foreign matter Non-armored cables shall contain one ripcord under the sheath for easy sheath removal. Armored cables shall contain two ripcords under the steel armor for easy armor removal. Additionally, armored cables that have an inner sheath will also contain one ripcord under the inner sheath All tensile strength shall be provided by the central member Non-armored cables shall be sheathed with medium density polyethylene (MDPE). The minimum nominal jacket thickness shall be 1.3 mm. Jacketing material shall be applied directly over cable core and water swellable tape. The polyethylene shall contain carbon black to provide ultraviolet light protection and shall not promote the growth of fungus Armored cables without an inner jacket shall have an armor layer applied directly over the cable core and water swellable tape. The armor shall be a corrugated steel tape, plastic-coated on both sides for corrosion resistance, and shall be applied around cable core and water swellable tape with an overlapping seam with the corrugations in register. The outer jacket shall be applied over the corrugated steel tape armor. The outer

4 March 2018, Revision: Issue Page 4 of 16 jacket shall be a MDPE with a minimum nominal jacket thickness of 1.3 mm. The polyethylene shall contain carbon black to provide ultraviolet light protection and shall not promote the growth of fungus The MDPE jacket material shall be as defined by ASTM D1248, Type II, Class C, Category 4 and Grades J4, E7 and E The jacket or sheath shall be free of holes, splits, and blisters The cable jacket shall contain no metal elements and shall be of a consistent thickness Cable jackets shall be marked with the manufacturer s name, month and year of manufacture, sequential meter or foot markings, a telecommunication handset symbol as required by Section 350G of the National Electrical Safety Code (NESC ), fiber count, and fiber type. The actual length of the cable shall be within -0/+1% of the length markings. The print color shall be white, with the exception that cable jackets containing one or more coextruded white stripes, which shall be printed in light blue. The height of the marking shall be approximately 2.5 mm If the initial marking fails to meet the specified requirements (i.e., improper text statement, color, legibility, or print interval), the cable may be remarked using a contrasting alternate color. The numbering sequence will differ from the previous numbering sequence, and a tag will be attached to both the outside end of the cable and to the reel to indicate the sequence of remarking. The preferred remarking color will be yellow, with the secondary choice being blue The maximum pulling tension shall be 2700 N (600 lbf) during installation (short term) and 890 N (200 lbf) long term installed The minimum bend radius shall be 15 times the cable outside diameter while under tension and 10 times the cable outside diameter installed The storage temperature range for the cable on the original shipping reel shall be -40 C to +70 C for all FlexNAP Trunk cable types. The installation temperature range for the cable shall be -30 C to + 70 C for Loose Tube cables and -18 C to +70 C for RPX Ribbon cables. The operating temperature range for the cable shall be -40 C to + 70 C for all FlexNAP Trunk cable types For RPX trunk designs the cable will be a flat profile with two dielectric or high strength steel central members on either side of a central cavity. The central cavity will house 24 fiber ribbons, separable by hand into 4 fiber ribbons. The ribbons will be surrounded by a protective water blocking tape and the overall cable construction will be gel-free For Figure-8 trunk designs, the optical cable and steel messenger shall be sheathed in medium density polyethylene (MDPE) with an MDPE web between the messenger and the optical cable. The web will couple the Corning Restricted

5 July 2018, Revision: Issue Page 5 of 16 cable to the messenger. The nominal thickness of the messenger sheath shall be 1.50 mm (0.06 inches). The web shall have a nominal height of 2.29 mm (0.09 inches) and a nominal thickness of 1.52 mm (0.06 inches) For Figure-8 trunk designs, an internal steel messenger shall be incorporated into the cable jacket. The messenger shall be a nominal 6.4 mm (0.25 inch) in diameter, extra high strength (EHS), 7 strand, Class A galvanized steel conforming to ASTM A 640. The messenger shall be galvanized for corrosion resistance and asphalt flooded to prevent the ingress of moisture. The minimum rated breaking strength of the messenger shall be kn (6,650 lbs). 4.0 Distribution Trunk Cable Assembly Construction 4.1 General Distribution Trunks shall be constructed from a cable type specified in Section Operating temperature range for cable portion of the trunks shall be as indicated in Section Distribution Trunks made from non-armored cables shall be of an all-dielectric construction Distribution Trunk fiber count shall be specified as 12, 24, 36, 48, 72, 96, 144, or 216 for Loose Tube cables Distribution Trunk fiber count shall be specified as 24, 48, 72, 96, or 144 for RPX Ribbon cables. 4.2 Distribution Trunk cables pre-terminated with MTP Connectors on the Central Office (CO)/ Wire Center (WC) CO / WC pre-terminated distribution trunk cable fiber counts shall be specified as 12, 24, 36, 48, 72, 96, and CO / WC pre-terminated distribution trunk cable types shall be specified as Single Mode Altos Dielectric Loose Tube cables only MTP connector furcation will begin with a 24 leg length and stagger 2 MTP connectors every Each cable buffer tube will be connectorized with a Single Mode MTP connector on the CO / WC end of the cable and numbered with a #1 label through a #12 in accordance with the TIA/EIA-598- B, Optical Fiber Cable Color Coding CO / WC Distribution Trunk cables pre-terminated with Single Mode MTP Connectors shall include a 600lb, water resistant, metal sheath pulling grip with pulling eye.

6 March 2018, Revision: Issue Page 6 of Distribution Trunk cables pre-terminated with HMFOC on the Central Office (CO)/ Wire Center (WC) CO / WC HMFOC pre-terminated distribution trunk cable fiber counts shall be specified as 12, 24, 36, and CO / WC HMFOC pre-terminated distribution trunk cable types shall be specified as Single Mode Altos Loose Tube cables and Single Mode RPX Ribbon cables HMFOC will be comprised of tether attachment points and tether assemblies, with the tether assemblies facing the CO/WC cable end Tether assembly lengths shall be 8 ft. for all applications Each cable buffer tube or ribbon will be connected to a HMFOC tether assembly on the CO / WC end of the cable and numbered with a label identifying its position within the distribution trunk CO / WC Distribution Trunk cables pre-terminated with HMFOC shall include a water resistant protective grip, and allow traditional cable installation methods to be used at the end of the cable. 4.4 Tether Attachment Point (TAP) & Tether Assembly Tether attachment points shall include a FlexNAP Distribution System closure (overmold) and a tether assembly HMFOC Tether lengths shall be 5 ft. for Aerial applications and 15 ft. for Direct Buried, Duct / Buried Duct. HFOC Tether lengths shall be 10 ft. for Aerial applications and 15 ft. for Direct Buried and Duct applications TAP distances shall be specified as the distance between tether attachment points at each designated section of the distribution trunk cable as specified by the end Customer or Contractor The FlexNAP Distribution System Closure shall meet the following specifications: The shipping, storage, and operating temperature range of the TAP shall meet or exceed the temperature ranges specified below: shipping, storage, and operating temperature range of -40 C to +70 C for Loose Tube and RPX Ribbon cables The TAP portion shall be flexible The TAP shall meet or exceed GR-3122 and GR-771. Corning Restricted

7 July 2018, Revision: Issue Page 7 of The dimensions of the premium Low Profile Overmold (28mm), All-Dielectric, Loose Tube TAP (Fiber count up to 72) will allow for installation into a 1.25 inch inside diameter duct. The TAP minimum bend radius shall be 24.2 cm (9.5 inches) during installation and 16.1 cm (6.4 inches) after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term The dimensions of the Standard Profile Overmold (36mm), All-Dielectric Loose Tube Cable TAP s (Fiber counts up to 72) will allow for installation into a 2 inch inside diameter duct. The TAP minimum bend radius shall be 24.2 cm (9.5 inches) during installation and 16.1 cm (6.4 inches) after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term The dimensions of the High Fiber Count Overmold (44mm), All-Dielectric, Loose Tube Cable TAP s (Fiber counts of 96,144 and 216) will allow for installation into a 2 inch inside diameter duct. The TAP minimum bend radius shall be 26.4 cm (10.4 inches) during installation and 17.6 cm (7.0 inches) after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term The dimensions of the standard Profile Overmold (44mm), Armor Lite, Loose Tube TAP s (Fiber count up to 72) will allow for installation into a 2 inch inside diameter duct. The TAP minimum bend radius shall be 18.2 cm (7.2 inches) during installation and 12.1 cm (4.8 inches) after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term The dimensions of the High Fiber Count Overmold (50mm), Armor Lite, Loose Tube TAP s (Fiber counts of 96, 144, and 216) will allow for installation into a 3 inch inside diameter duct. The TAP minimum bend radius shall be 20.7 cm (8.1 inches) for 96 fiber, 26.3 cm (10.4 inches) for 144 fiber, and 26.6 cm (10.5 inches) for 216 fiber during installation and 13.8 cm (5.4 inches) for 96 fiber, 17.5 cm (6.9 inches) for 144 fiber, and 17.7 cm (7.0 inches) for 216 fiber after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term The dimensions of the RPX Ribbon Overmold (33mm) TAP s (Fiber counts of 24, 48, 72, 96, and 144) is approved for Aerial or buried applications. The TAP minimum bend radius shall be 22.9 cm (9.0 inches) during installation and 22.9 cm (9.0 inches) after installation. The TAP maximum tensile load shall be 2700 N (600 lb f ) short term and 890 N (200 lb f ) long term.

8 March 2018, Revision: Issue Page 8 of Tether Assemblies shall be terminated with a pinned Hardened MT connector or Hardened SC connector for aerial and direct buried/duct applications. For Façade FlexNAP applications or CO preterminated locations the tether assemblies shall be terminated with a non-pinned Hardened MT connector Operating temperature range of the terminated portion of the tether assembly (terminated with Hardened connector) shall be -40 C to + 70 C Single Tether Assembly fiber count shall be specified as 1, 2, 4, 6, 8, or 12 fibers for Loose Tube cables and 4, 8 or 12 for RPX Ribbon cables Tether Attachment Points can support a maximum of two single tether assemblies for a maximum of 24 fibers per TAP for non Premium Low Profile overmolds. Premium Low Profile overmolds closures can only support one, 12 fiber tether assembly per access point. Dual access points are required for 24 fibers per location Tether Assembly Hardened connectors will meet specifications in Table 1 below: Connector Type Fiber Count Insertion Loss Reflectance Polish Hardened single-mode MT Connector 2, 4, 6, 8, db typical 0.62 db max < -65 db 8 o Hardened single-mode SC Connector db typical 0.4 db max Table 1: Hardened Connector Specifications 5.0 General Hardened MT Connector Specifications < -65 db 8 o 5.1 The hardened MT connector shall be available in fiber counts of 2, 4, 6, 8 and 12 for Loose Tube cables and 4, 8, and 12 fiber count connectors for RPX Ribbon cables. 5.2 The hardened MT connector shall have an 8º angled end face for single mode and shall always mate key up to key down. The connector Corning Restricted

9 July 2018, Revision: Issue Page 9 of 16 housings shall be keyed to ensure proper connector mating relative to the end face angle. 5.3 The largest diameter of the connector housing shall be 17.5 mm, and the assembly terminated with this connector shall be designed to fit through 1.25 duct. 5.4 Connector alignment shall be achieved through 2 alignment pins located in the pinned hardened MT connector. 5.5 The hardened MT connector is designed to meet the applicable performance criteria of GR-3152, IP 69K, and IP When tested in accordance with FOTP-1, "Cable Flexing for Fiber Optic Connectors", the assembly shall be mounted to a cable tension test device with a weight of 0.9kg. Each assembly is rotated through the angles of +90 to 90 degrees for a total of 100 cycles. Measurements of loss and reflectance are made at the beginning and at the end of the test. At the end of the test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 5.7 The assembly shall not become uncoupled when subjected to the following series of the tests. The test sample shall undergo a series of straight pulls (4.5 kgf (10 lbf) 0 for 5 sec, wait 10 sec to measure, then 6.8 kgf (15 lbf) at 0 5 sec, wait 10 sec to measure) and 90 o side pulls (2.3 kgf (5 lbf) 0 for 5 sec, wait 20 sec to measure, then 3.4 kgf (7.5 lbf) at 0 for 5 sec, wait 20 sec to measure). At the end of the test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 5.8 When tested in accordance with FOTP-2, "Impact Test Measurements for Fiber Optic Devices", each assembly is subjected to eight impact cycles by being dropped from a height of 1.5m. Each connector was cleaned after the test and re-mated. Measurements of maximum loss and reflectance were measured before and after the impacts. At the end of the test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 5.9 When tested in accordance with FOTP-21, "Mating Durability for Fiber Optic Interconnecting Devices", each assembly is disconnected and then reconnected 200 times. The assemblies are cleaned after every 25th mating. Measurements of loss and reflectance are made before and after each cleaning cycle. At the end of the durability test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of

10 March 2018, Revision: Issue Page 10 of db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db The HMFOC assembly shall show no evidence of water leakage as a result of the applied Seal Under Load Test method. The side load applied shall be 2.5 lbs while being placed under 10 feet of waterhead The HMFOC assembly shall not permanently deform more than 10%, nor temporarily deform more than 20%, when it is compressed by a uniformly distributed load. In addition, application of the compressive load shall not cause any mechanical damage to the closure or its contents. The applicable compressive loads are 300 lbs for the buried/underground environment and 100 lbs for all other deployment environments The HMFOC shall meet the Rockwell R87 material hardness specification to meet the rodent resistance requirement When tested in accordance with FOTP-3, "Procedure to Measure Temperature Cycling Effects on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components", each assembly is subjected to test conditions ranging from 23 C to 75 C to -40 C for 500 hrs. Measurements of loss and reflectance are made at the beginning, at each temperature plateau and at the end of the test or other interim measurements such as 50, 100, 168, 220, 310, 425, and 500 hour intervals. At the end of the temperature cycling each connector shall maintain a maximum insertion loss of 0.75 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-4, "Fiber Optic Component Temperature Life Test", each assembly is subjected to test conditions of 85 C and < 40% RH for 2000 hrs. Measurements of loss and reflectance are made at the beginning, at 168 hr., at 500 hr., at 1000 hr. and at the end of the test. At the end of the temperature life test each connector shall maintain a maximum insertion loss of 0.75 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-5 "Humidity Test Procedure for Fiber Optic Components", test type 1, each connector assembly is subjected to test conditions of 75 C and 90% relative humidity for 1000 hrs. Measurements of loss and reflectance are made at the beginning of the test, at 100 hrs, at 168 hrs, at 500 hrs, and at the end of the test. At the end test each connector shall maintain a maximum insertion loss of 0.75 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-16, Salt Spray Test", each connector assembly shall subjected to a 5% (±1%) NaCl by weight dissolved in distilled water solution over a period of 168 hrs. (7 days). At Corning Restricted

11 July 2018, Revision: Issue Page 11 of 16 the beginning and end of the test each connector shall maintain a maximum insertion loss of 0.75 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with ASTM B827-92, Airborne Contaminants Test, each connector assembly shall be subjected each of the following gases over a period of 20 days individually: 20ppb Cl 2, 100ppm H 2 S, 200ppm NO 2, and 200ppb SO 2. At the end of the test and before cleaning each connector shall maintain a maximum insertion loss of 0.75 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db with no visible corrosion When tested in accordance with ASTM G21, Fungus Resistance Test, each connector assembly shall achieve a rating of When tested in accordance with UL-94 and ASTM D , Flammability Test, each connector assembly shall have a material rating of V-1 or better and an oxygen index of 28 percent or better respectively The connector assemblies shall show no evidence of cracking when exposed over a period of 24 hrs. to the following: WD-40 Water Displacing Lubricant, 10% IGEPAL, Cable Filling Compound, as used in the field, Splice Encapsulating Compound, Isopropyl Alcohol Grade HPLC, and Wasp & Hornet Spray Each connector assembly shall show no change in sealing ability and shall not experience a reduction in either tensile strength or elongation properties greater than 20% after submersion in a specified chemical test fluid for 7 days. The chemicals to be used are: Sulfuric Acid (3% H2SO4 by weight), Sodium Hydroxide (0.2 NaOH), IGEPAL (10%), and Kerosene (having flash point > 160 F) The connector endface shall meet the geometry requirements as stated in IEC Part General Single Fiber Hardened Fiber Optic Connector Performance Specifications 6.1 The connector will be free of any defects such as burrs that may present a hazard safety or otherwise to the user. 6.2 When tested in accordance with FOTP-3, "Procedure to Measure Temperature Cycling Effects on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components", the connector shall be put through 21 cycles (168hrs) with a temperature range -40 o C to 75 o C for each cycle. At the end of the temperature cycling the connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db,

12 March 2018, Revision: Issue Page 12 of 16 and a reflectance change of 5 db. The loss measurements are done before and after every cycle and at each temperature plateau. 6.3 When tested in accordance with FOTP-4, "Fiber Optic Component Temperature Life Test" ", the connector shall be placed in an 85 o C environment with uncontrolled humidity for 168hrs. At the end of the temperature life test the connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. The measurement is done before and after the test. 6.4 When tested in accordance with FOTP-5, "Humidity Test Procedure for Fiber Optic Components", each connector undergoes two tests: a Humidity Aging Test and a Humidity/Condensation test. For the Humidity Aging test each connector is subjected to test conditions of 75 C and 95% relative humidity for 7 days. Measurements of loss and reflectance are made at the beginning of the test, at a minimum of six-hour intervals during the test, and at the end of the test. For the Humidity/ Condensation test each connector is subjected to the temperature cycle of 10oC to 65oC, with relative humidity of 90 to 100%, for a period of 7 days. Measurements of loss and reflectance are made at every temperature plateau, and at 23 C at the end of the test, at least thirty minutes after the start of each plateau interval. At the end of either test the connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. The loss measurements are done at the beginning and end of the test and every six hours during the test. 6.5 When tested in accordance with FOTP-12, "Fluid Immersion Test for Fiber Optic Components, the connector shall be submersed in groundwater for 168 hrs. At the end of the groundwater submersion test the connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. The loss measurements are done at the beginning and end of the test. 6.6 When tested in accordance with FOTP-12, the connectors shall be submerged in the following chemicals: Kerosene, IGEPAL 10%, Sodium Hydroxide, and Sulfuric Acid. The connectors shall only be smeared with the following chemicals: WD-40, Wasp & Hornet Spray, Isopropyl Alcohol, Cable-filling compound, Splice Encapsulating compound, and IGEPAL 10%. After being submerged or smeared for the required time, the connectors will be cleaned with water then checked for cracks or any other physical deformations. 6.7 When tested in accordance with FOTP-1, "Cable Flexing for Fiber Optic Connectors", the assembly shall be mounted to a cable tension test device with a weight of 0.9kg. Each assembly is rotated through the angles of +90 to 90 degrees for a total of 100 cycles. Measurements of loss and reflectance are made at the beginning and at the end of the test. At the end of the test each connector shall maintain a maximum insertion loss of Corning Restricted

13 July 2018, Revision: Issue Page 13 of db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 6.8 When tested in accordance with FOTP-2, "Impact Test Measurements for Fiber Optic Devices", each assembly is subjected to eight impact cycles by being dropped from a height of 1.5 m. Each connector was cleaned after the test and re-mated. Measurements of maximum loss and reflectance were measured before and after the impacts. At the end of the test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 6.9 When tested in accordance with FOTP-3, "Procedure to Measure Temperature Cycling Effects on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components", each assembly is subjected to test conditions ranging from 23 C to 75 C to -40 C for 7 days and a total of 21 cycles. Measurements of loss and reflectance were made at the beginning, at each temperature plateau and at the end of the test. At the end of the temperature cycling each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-4, "Fiber Optic Component Temperature Life Test", each assembly is subjected to test conditions of 85 C for 7 days. Measurements of loss and reflectance are made at the beginning of the test and at the end of the test. At the end of the temperature life test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-5 "Humidity Test Procedure for Fiber Optic Components", each cable assembly undergoes two tests: a Humidity Aging Test and a Humidity/Condensation test. For the Humidity Aging test each connector assembly is subjected to test conditions of 75 C and 95% relative humidity for 7 days. Measurements of loss and reflectance are made at the beginning of the test, at a minimum of six-hour intervals during the test, and at the end of the test. For the Humidity/ Condensation test each assembly is subjected to the temperature cycle of 10oC to 65oC, with relative humidity of 90 to 100%, for a period of 7 days. Measurements of loss and reflectance are made at every temperature plateau, and at 23 C at the end of the test, at least thirty minutes after the start of each plateau interval. At the end of either test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. The loss measurements are

14 March 2018, Revision: Issue Page 14 of 16 done at the beginning and end of the test and every six hours during the test When tested in accordance with FOTP-6, Cable Retention Test Procedure for Fiber Optic Cable Interconnecting Devices," each assembly is mounted onto a text fixture device, and tension is then applied at 0o and 90o offset from the boot of the connector. The tension applied starts at 0.25 and is gradually increased to 0.7kg, 1.5kg, and finally 2.0kg. At the end of the test each connector shall maintain an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. The loss measurements are made while the tensile load is applied When tested in accordance with FOTP-11, "Vibration Test Procedures for Fiber Optic Components and Cables", each connector assemblies is tested with a vibration amplitude of 1.5 mm (peak-to-peak), with a frequency range sweeping from 10 to 55 Hz at a rate of 45 Hz per minute. The test is conducted for 2 hours in each of three planes. Measurements of loss and reflectance are made at the beginning of the test and after vibration in each of the three planes. At the end of the vibration test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-21, Mating Durability for Fiber Optic Interconnecting Devices", each assembly is disconnected and then reconnected 200 times. The assemblies are cleaned after every 25th mating. Measurements of loss and reflectance are made before and after each cleaning cycle. At the end of the durability test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db When tested in accordance with FOTP-36, "Twist Test for Fiber Optic Connecting Devices", each assembly is mounted to a cable tension test device with a weight of 1.35 kg. The assembly is then twisted +2.5 revolutions to 2.5 revolutions (from the starting point) about the axis of the cable (10 cycles in total). After that, it was rotated + 5Y revolutions in one direction, then was reversed direction and rotated another + 5Y revolutions, for a total of 10 cycles. Measurements of loss and reflectance are made at the beginning and at the end of the test. At the end of the twist test each connector shall maintain a maximum insertion loss of 0.50 db, a mean insertion loss of 0.30 db, an insertion loss increase of 0.30 db, a maximum reflectance of -40 db, and a reflectance change of 5 db. 7.0 General Cable Performance Specifications 7.1 When tested in accordance with FOTP-3, "Procedure to Measure Temperature Cycling Effects on Optical Fibers, Optical Cable, and Other Passive Fiber Optic Components," the change in attenuation at extreme operational temperatures (-40 C and +70 C) shall not exceed 0.15 db/km at 1550 nm for single-mode fiber. Corning Restricted

15 July 2018, Revision: Issue Page 15 of When tested in accordance with FOTP-82, "Fluid Penetration Test for Fluid-Blocked Fiber Optic Cable," a one meter length of unaged cable shall withstand a one meter static head or equivalent continuous pressure of water for one hour without leakage through the open cable end. 7.3 When tested in accordance with FOTP-81, "Compound Flow (Drip) Test for Filled Fiber Optic Cable," the cable shall exhibit no flow (drip or leak) of filling and/or flooding material at 70 C. 7.4 When tested in accordance with FOTP-41, "Compressive Loading Resistance of Fiber Optic Cables," the cable shall withstand a minimum compressive load of 220 N/cm (125 lbf/in) applied uniformly over the length of the sample. The 220 N/cm (125 lbf/in) load shall be applied at a rate of 2.5 mm (0.1 in) per minute. The load shall be maintained for a period of 1 minute. The load shall then be decreased to 110 N/cm (63 lbf/in). Alternatively, it is acceptable to remove the 220 N/cm (125 lbf/in) load entirely and apply the 110 N/cm (63 lbf/in) load within five minutes at a rate of 2.5 mm (0.1 in) per minute. The 110 N/cm (63 lbf/in) load shall be maintained for a period of 10 minutes. Attenuation measurements shall be performed before release of the 110 N/cm (63 lbf/in) load. The change in attenuation shall not exceed 0.15 db at 1550 nm for single-mode fibers. 7.5 When tested in accordance with FOTP-104, "Fiber Optic Cable Cyclic Flexing Test," the cable shall withstand 25 mechanical flexing cycles around a sheave diameter not greater than 20 times the cable diameter. The change in attenuation shall not exceed 0.15 db at 1550 nm for singlemode fiber. 7.6 When tested in accordance with FOTP-25, "Repeated Impact Testing of Fiber Optic Cables and Cable Assemblies," except that the number of cycles shall be two at three locations along a one meter cable length and the impact energy shall be atleast 4.4 Nm (in accordance with ICEA S ), the change in attenuation shall not exceed 0.15 db at 1550 nm for single-mode fiber. 7.7 When tested in accordance with FOTP-33, "Fiber Optic Cable Tensile Loading and Bending Test," using a maximum mandrel and sheave diameter of 560 mm, the cable shall withstand a rated tensile load of 2670N (601 lbf) and residual load of 30% of the rated installation load. The axial fiber strain shall be 60% of the fiber proof level after completion of 60 minute conditioning and while the cable is under the rated installation load. The axial fiber strain shall be 20% of the fiber proof level after completion of 10 minute conditioning and while the cable is under the residual load. The change in attenuation at residual load and after load removal shall not exceed 0.15 db at 1550 nm for single mode fiber. 7.8 When tested in accordance with FOTP-85, "Fiber Optic Cable Twist Test," a length of cable no greater than 2 meters shall withstand 10 cycles of mechanical twisting. The change in attenuation shall not exceed 0.15 db at 1550 nm for single-mode fiber.

16 March 2018, Revision: Issue Page 16 of When tested in accordance with FOTP-181, "Lightning Damage Susceptibility Test for Optic Cables with Metallic Components," the cable shall withstand a simulated lightning strike with a peak value of the current pulse equal to 55 ka without loss of fiber continuity. A damped oscillatory test current shall be used with a maximum time-to-peak value of 15 µs (which corresponds to a minimum frequency of 16.7 khz) and a maximum frequency of 30 khz. The time to half-value of the waveform envelope shall be from 40 to 70 µs When tested in accordance with FOTP-37, "Low or High Temperature Bend Test for Fiber Optic Cable," the cable shall withstand four full turns around a mandrel of 20 times the cable diameter after conditioning for four hours at test temperatures of -30 C and +60 C. Neither the inner or outer surfaces of the jacket shall exhibit visible cracks, splits, tears, or other openings. The change in attenuation shall not exceed 0.30 db at 1550 nm for single mode fiber. 8.0 Quality Assurance Provisions 8.1 All cable assemblies of any length shall be 100% attenuation tested. 8.2 All cable assemblies shall be tested in from both ends of each link within the cable. 8.3 The cable manufacturer shall be ISO 9001 registered. 9.0 Packaging 9.1 The completed cable shall be packaged for shipment on varying size plastic, composite and wooden reels Miscellaneous 10.1 At the request of the customer, the cable manufacturer shall provide installation procedures and technical support concerning the items contained in this specification. Corning Restricted

features and benefits

features and benefits features and benefits Fully waterblocked loose tube, gel-free design Medium-density polyethylene jacket Figure-8 cable design Available in 62.5 µm, 50 µm, single-mode and hybrid versions Simple access

More information

Single-Armored Cables, Fibers

Single-Armored Cables, Fibers Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease

More information

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease

More information

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet,

More information

Fiber Optic Outside Plant Cables (4-144 Fibers)

Fiber Optic Outside Plant Cables (4-144 Fibers) Fiber Optic Outside Plant Cables (4-144 ) Central Tube Dielectric Cable 4-12 Fiber Water Blocking Strength Members Multi-Tube Dielectric Cable 24-216 Fiber The number of tubes changes depending on fiber

More information

Ø 1250 * 688 mm 93 kg ± 105m

Ø 1250 * 688 mm 93 kg ± 105m GCDE Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection 05-05-5 v7.0 Ordering Information Belden Part Numbers Fibre Description

More information

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev. Page 1 of 5 Scope: The scope of this procedure is to describe how to properly install a cable pulling grip on an Optical Cable Corporation interlocked armor (ILA) and corrugated steel tape (CST) fiber

More information

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D Product Model: GYFXTY 2~12C Our Ref: No.TS-FT201107-03-64-V1.0 GENERAL 1.1 These optical cables have excellent protection, optical transmission and mechanical

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş. Technical Specification Revision/Date:01/02.15 By S.Erol Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSLT41DYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657 A2

More information

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, Fig 8 Armored, Multi Tube Outdoor, Fig 8 Armored, Multi Tube Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,

More information

Canadian OSP Copper I-1. Table of Contents

Canadian OSP Copper I-1. Table of Contents Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,

More information

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0 ITEM MODEL NO. ADSS Fiber Optic Cable A-288-XX DESCRIPTION 2-288 core, Single-mode/Multi-mode Overview AOA-ADSS cable is ideal for installation in distribution as well as transmission environments, even

More information

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA NOTE: These installation instructions have been written for

More information

Sabritec Qualification Test Report Summary

Sabritec Qualification Test Report Summary Sabritec Qualification Summary Qualification of Multimode Fiber Optic Termini, and Type 1, Category 2 Connectors per ARINC Specification 801 QTR #705 03-27-08 Revision Page Paragraph Description of Revision

More information

Exhibit A Construction Project Manual and Drawings

Exhibit A Construction Project Manual and Drawings Exhibit A Construction Project Manual and Drawings Summary Starting the summer of 2015 TxDOT will be adding a Toll lane to Hwy 288 with fly over exits and entrances in the area of Holcombe Blvd. and Ardmore

More information

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application (SM 12 Fibers) Product: Single Mode Optical Fiber Cable Customer: Date: Write by: Kevin Zhou / technical engineer International

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

IBER OPTIC ATTENUATOR (FC/UPC, SC/UPC,

IBER OPTIC ATTENUATOR (FC/UPC, SC/UPC, F IBER OPTIC ATTENUATOR (FC/UPC, SC/UPC, LC/UPC) 1. GENERAL This specification covers the requirements of the standard attenuator for single mode optical fiber to be supplied to TOT Public Company Limited

More information

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE Air Blown Micro LC Cable ITU-T G.652.D 6~72F Customer : Czech Atlantis Date : Oct. 31. 2007 Author : MinLi Fu Manager : HanDong Choi Department :

More information

MAG-MATE* Series 300 Terminals

MAG-MATE* Series 300 Terminals MAG-MATE* Series 300 Terminals Application Specification 114-2046 28 NOV 18 Rev AB All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].

More information

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements

More information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits GAAG Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)Y(T) 05-04-9 v4.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GAAG04 GAAG08 GAAG GAAG8 GAAG4 GAAG30 GAAG36

More information

Datasheet Outside Plant Cable

Datasheet Outside Plant Cable Outside Plant Cable Direct Buried Cable Direct buried cable can be buried directly into the ground in a trench or using a vibratory plow. Except for with great water-blocking and moisture-proof performance,

More information

Section 914. JOINT AND WATERPROOFING MATERIALS

Section 914. JOINT AND WATERPROOFING MATERIALS 914.01 Section 914. JOINT AND WATERPROOFING MATERIALS 914.01. General Requirements. Joint and waterproofing material for use in concrete construction must meet the requirements of this section. 914.02.

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application (SM 24, 36, 48, 64, 96 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM L TD. / Bulgaira Date: August 1, 2012 Write

More information

Filled Solid ALPETH Cable

Filled Solid ALPETH Cable I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive

More information

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5. GUXW Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection 05--0 v5.0 Ordering Information Belden Part Numbers Fibre Description / count

More information

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002 National Radio Astronomy Observatory Socorro, NM 87801 EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable T. Baldwin June 05, 2002 Summary Double-armor triple-sheath fiber optic cable will be

More information

SOLARLOK PV BAR Junction Box

SOLARLOK PV BAR Junction Box SOLARLOK PV BAR Junction Box Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 3 2. APPLICABLE DOCUMENTS... 3 2.1. TE Connectivity Documents... 3 2.2. Commercial Standard... 3 3.

More information

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED INCH-POUND 17 June 1996 SUPERSEDING MIL-I-23053/4C 01 May 1986 DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED This specification

More information

Installation Instructions. for AFL Dead Ends Installed on. CTC Composite Core Conductor

Installation Instructions. for AFL Dead Ends Installed on. CTC Composite Core Conductor Installation Instructions for AFL Dead Ends Installed on CTC Composite Core Conductor NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS ARE THE PROPERTY OF AFL,

More information

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested

More information

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS E&P Pag. 1 / 14 Pre-salt Standard Steel Tube Umbilical Types Umbilical Electrical Cable Element DPT-SUB/ES/DCT INDEX OF REVISIONS REV DESCRIPTION AND/OR AFFECTED SHEETS 0 Original ORIGINAL REV. A REV.

More information

Initial release of document

Initial release of document This specification covers the requirements for application of SMT Poke In Connectors for use on printed circuit (pc) board based LED strip lighting typically used for sign lighting. The connector accommodates

More information

3M IDC Ribbon Cable Socket. Series 891

3M IDC Ribbon Cable Socket. Series 891 78-51-- Rev A 1 of 8 M IDC Ribbon Cable Socket Series 891 Product Specification 78-51-- Released: 9-7-11 Austin, TX 7876-9 78-51-- Rev A of 8 Table of Contents Section Page 1. Scope........ M Customer

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 0.8x1.2 mm Board to Board Socket Connectors Page 1 1.0 SCOPE This specifies 0.8x1.2mm pitch Socket Connectors. The connector shall meet the performances, specified here under the condition with the plug

More information

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm GYFY-24FO Total Dry Filler FRP center strength member Strength member Rip cord Dielectric strength members Aramid yarns Additional strength member Filler PP Diameter same as tube Colors of tubes is : blue,

More information

Generic Requirements for Fiber Optic Attenuators. Contents

Generic Requirements for Fiber Optic Attenuators. Contents Generic Requirements for Fiber Optic Attenuators Preface... Preface 1 1. Introduction...1 1 1.1 Document Description...1 1 1.2 Requirements Terminology... 1 1 1.3 Requirement Labeling Conventions... 1

More information

Connection technology for wireless communication systems

Connection technology for wireless communication systems Connection technology for wireless communication systems Rosenberger Rosenberger, founded in 1958, is a family owned company and ranks today among the top global manufacturers of high-frequency coaxial

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information

NORMATIVE REFERENCES

NORMATIVE REFERENCES American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and

More information

Solder Tine Terminal Crimp Wire Terminal. Retention Barb Carrier Strip. Wire Lead-In. Slotted Beams Housing (Customer Supplied) Figure 1

Solder Tine Terminal Crimp Wire Terminal. Retention Barb Carrier Strip. Wire Lead-In. Slotted Beams Housing (Customer Supplied) Figure 1 MAG-MATE* Series 187 Terminals Application Specification 114-2069 28 NOV 18 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].

More information

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3 Splice Closure for Fiber Optic Cable 1. Introduction 1.1 General VISSEM S BS403A protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct

More information

Installation Instructions. for AFL Compression Joint Installed on. CTC Composite Core Conductor

Installation Instructions. for AFL Compression Joint Installed on. CTC Composite Core Conductor Installation Instructions for AFL Compression Joint Installed on CTC Composite Core Conductor NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS ARE THE PROPERTY

More information

Z EE E E Z E Z Z Z Z Z

Z EE E E Z E Z Z Z Z Z E A Furukawa Company Z EE E E Z E Z Z Z Z Z Optimized for Multiple Dwelling Unit (MDU) Drop and In-Home Wiring Applications EZ-Bend Optical Cables help speed and simplify indoor optical drop cable installations

More information

Ø560*336mm 4.25 kg 2100 ± 105m

Ø560*336mm 4.25 kg 2100 ± 105m GUMT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)H Standard Rodent Protection 05-0-0 v3.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM

More information

NORMATIVE REFERENCES

NORMATIVE REFERENCES American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and

More information

Pre-printed PVC Cable Markers O-Type, K-type, Z-type, V-Type

Pre-printed PVC Cable Markers O-Type, K-type, Z-type, V-Type RW-2535 Issue 2 Page 1 of 17 Oct 2013 Specification RW-2535 Document Number: 108-121034 Pre-printed PVC Cable Markers O-Type, K-type, Z-type, V-Type SCOPE This quality assurance specification establishes

More information

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team PAGE : 1 OF 6 LSSS-OF0007-00 FOR Zero Water Peak Single-Mode Optical Fiber (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team Checked by Yu-Hyoung Lee Manager Passive Solution

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

SIAMEZE* Standard and Fine Range Terminals

SIAMEZE* Standard and Fine Range Terminals SIAMEZE* Standard and Fine Range Terminals Application Specification 25 JAN 19 Rev E NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

SPECIFICATION. Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable SPECIFICATION Optical Fiber Cable (GYDXTW 24~432) Prepared by Zhang xin Approved by Yao qiang 1 General 11 This specification covers the requirements for the supply of single-mode optical fiber cables

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 2.54mm Board to Board Socket Connectors Page 1 1.0 SCOPE This specifies 2.54mm pitch Socket Connectors. The connector shall meet the performances, specified here under the condition with the plug connector

More information

KP 376 KP/MMKP 376. AC and pulse metallized polypropylene film capacitors. Fig.1 Simplified outlines.

KP 376 KP/MMKP 376. AC and pulse metallized polypropylene film capacitors. Fig.1 Simplified outlines. KP AND KP/MMKP RADIAL POTTED CAPACITORS PITCH 15/22.5/27.5 mm P=15 mm P = 22.5 to 27.5 mm DR931960 Fig.1 Simplified outlines. FEATURES 15.0 to 27.5 mm lead pitch Supplied loose in box and taped on reel.

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 2.54mm Board to Board Header Connectors Page 1 1.0 SCOPE This specifies Pitch 2.54mm Headers Connectors. The connector shall meet the performances, specified here under the condition with the plug connector

More information

Product Specification provides test and performance results for insulated terminals and splices for Class 1 E Nuclear applications.

Product Specification provides test and performance results for insulated terminals and splices for Class 1 E Nuclear applications. This specification covers the requirements for application of PIDG terminals, splices, and end caps in various operating environments. Each consists of a precision formed metal wire barrel and a copper

More information

Metallized Polycarbonate film capacitors MKC 344

Metallized Polycarbonate film capacitors MKC 344 MKC RADIAL POTTED CAPACITORS PITCH 10/15/22.5/27.5 mm handbook, full pagewidth P = 10 mm P = 15 mm P = 22.5 to 27.5 mm DR931980 Fig.1 Simplified outlines. FEATURES 10 to 27.5 mm lead pitch Small dimensions

More information

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications.

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications. ATBTK-MF-4G Bias Tee Kit, AISG Compatible 698-2700 MHz Product Classification Product Type RET bias tee Mechanical Specifications Antenna Interface 7-16 DIN Female BTS Interface 7-16 DIN Male Dimensions

More information

A S J ASJ PTE LTD LEAD FREE THIN FILM CHIP RESISTOR SPECIFICATION. Reference No. : SYS-ENG-209. Revision No. : D

A S J ASJ PTE LTD LEAD FREE THIN FILM CHIP RESISTOR SPECIFICATION. Reference No. : SYS-ENG-209. Revision No. : D ASJ PTE LTD LEAD FREE THIN FILM CHIP Reference No. : SYS-ENG-209 Revision No. : D DOC NO: SYS-ENG-209 PAGE: 2 of 24 1.0 SCOPE...... 3 2.0 PART NUMBERING SYSTEM...... 3 3.0 RATING....... 3 3.1 Rated Power......

More information

u n a B Optical Cables UNIFLEX CABLES LTD.

u n a B Optical Cables UNIFLEX CABLES LTD. u n a B Optical Cables UNIFLEX CABLES LTD. Established in 1981, UNIFLEX CABLES LIMITED manufactures a variety of top quality cables in India with a factory size of 15,000 sq. mts. in Umergaon (Gujarat).

More information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information GORN Central Loose Tube Cables Outdoor A-DQ(ZN)BY Improved Rodent Protection, 000N Permanent Load 05--0 v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GORN0

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction: Dax DX-S10121 (12F Single Mode Armoured Fiber Cable -Uni-Tube Design) Introduction: Dax DX-S1012burial installations, providing outstanding mechanical protection and rodent resistance. is a12 core Single

More information

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX The OptiSheath Advantage Sealed Terminal for WDM Applications, UCA4 enables operators to maximize the potential of their existing

More information

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications HS Series Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements of U.R.D., submersible,

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Technical specification SiMTaCS Single Mode Tactical Cable System

Technical specification SiMTaCS Single Mode Tactical Cable System 1 (104) Technical specification SiMTaCS Single Mode Tactical Cable System Ola Winberg, FMV AK LED/TeknLedn Annika Sjödin, FMV AK LED/Inköp 2 (104) TABLE OF CONTENTS 1 GENERAL INFORMATION... 6 1.1 Introduction...

More information

INSPECTION AND REMOVAL CRITERIA

INSPECTION AND REMOVAL CRITERIA INSPECTION AND REMOVAL CRITERIA ASME B30.9-1 ALLOY STEEL CHAIN SLINGS 9-1.9.5 Removal Criteria Missing or illegible sling identification. Cracks or breaks. Excessive wear, nicks, or gouges. Stretched chain

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: SCREW PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3654 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00

More information

2. Conductor insulation should be supported and gripped by the terminal.

2. Conductor insulation should be supported and gripped by the terminal. 2015 Part 14.1.1 Recommended Design Criteria and Functional/Operating Guidelines for Solderless Crimp-Type Wire Terminals for Use in Wiring Signal Apparatus Revised 2015 (6 Pages) A. Purpose This Manual

More information

PRO BEAM Series PRO BEAM expanded beam field deployable interconnect F739

PRO BEAM Series PRO BEAM expanded beam field deployable interconnect F739 PRO BEAM Series PRO BEAM expanded beam field deployable interconnect F739 12 PRO BEAM is a registered trade mark of TE Connectivity 12-2 CONTENTS Pages PRO BEAM Introduction... 12-4 Benefits of the expanded

More information

Standard Monotube SAFE

Standard Monotube SAFE Application Mainly used in outside plant to building transitions and inter-building installations Fiber Count Single Mode Fibers Outer Diameter [mm] Cable Weight [kg/km] Design Optical Fibers Gel-filled

More information

HIGH POWER COLLIMATORS AND FOCUSERS PIGTAIL STYLE

HIGH POWER COLLIMATORS AND FOCUSERS PIGTAIL STYLE Features HIGH POWER COLLIMATORS AND FOCUSERS PIGTAIL STYLE High power handling Rugged and compact design Low insertion loss Low backreflection Wide wavelength range Wide range of beam diameters Aspheric,

More information

CONTENTS. Introduction Characteristics Product range Pages

CONTENTS. Introduction Characteristics Product range Pages OSIS tm Series OSIS CONTENTS OSIS TM Pages Introduction...10-4 Characteristics...10-5 Product range...10-6 OSIS TM plug kit...10-6 OSIS TM receptacle...10-7 OSIS TM pre-mounted optical cable assemblies...10-8

More information

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C240-NFSM-3M Product Classification Brand Product Series Product Type CNT Jumper with interface types N Female and SMA Male, 3m CNT Braided cable assembly General Specifications Body Style, Connector A

More information

Ortel (Lucent) Fiber Optic Interface

Ortel (Lucent) Fiber Optic Interface Ortel (Lucent) Fiber Optic Interface 144-701-1 Serial Number May 5, 2009 Revision B ORTEL (LUCENT) FIBER OPTIC INTERFACE 1. GENERAL INFORMATION... 1 1.1. SCOPE OF OPTION... 1 1.2. PURPOSE OF EQUIPMENT...

More information

Handling Precaution for Terminal and Connector

Handling Precaution for Terminal and Connector 1 Handling Precaution for Terminal and Connector Handling Precaution for Terminal and Connector This manual is to describe basic precautions for use of terminal and connector in the following. Make use

More information

Product Specification - LPM Connector Family

Product Specification - LPM Connector Family LPM Product Specification - LPM OVERVIEW Developed for mobile devices and other space-constrained applications, the Neoconix LPM line of connectors feature exceptional X-Y-Z density with a simple, highly

More information

Miniature Waterproof Shielded Connectors

Miniature Waterproof Shielded Connectors Miniature Waterproof Shielded Connectors LF Series Mated dimensions 8.9 mm max. ( pos.). Ø Receptacle Plug Short turn bayonet lock Features. Ease of shielded termination and connector assembly All components

More information

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications C400-TMTM-30-X Product Classification Brand Product Series Product Type CNT-400-FR CNT Jumper with interface types TNC Male and TNC Male, 9.14 m CNT CNT-400 Braided cable assembly General Specifications

More information

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

FIELD LOK 350. Gasket 4 24 JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61 4" 24" FIELD LOK 350 JOINT RESTRAINT Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 4" 24" FIELD LOK 350 Gasket 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative

More information

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers) TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED (SM 2~24 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM LTD. / Bulgaira Date: August 1, 2012 Write by: Petar Georgiev

More information

Qualification Test Report SlimSeal SSL Connector

Qualification Test Report SlimSeal SSL Connector Qualification Test Report SlimSeal SSL Connector 501-134042 6/26/15 Rev A 1. INTRODUCTION 1.1 Purpose Testing was performed on the TE Connectivity SlimSeal SSL Connector to determine its conformance to

More information

SYSTIMAX 360 ipatch Fiber Shelf with Faceplate Instructions

SYSTIMAX 360 ipatch Fiber Shelf with Faceplate Instructions 860463082 Issue 5, June 2014 SYSTIMAX 360 ipatch Fiber Shelf with Faceplate Instructions General The SYSTIMAX 360 ipatch G2 fiber shelf with faceplate is a SYSTIMAX approved product. This distribution

More information

Cable Type 100. CAI Certification Specification

Cable Type 100. CAI Certification Specification Cable Type 100 CAI Certification Specification Ref: CAI-007-C / 100 / 12-2016 Confederation of Aerial Industries Ltd Communications House 41a Market Street WATFORD Herts WD18 0PN Tel: 01923 803030 Fax:

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

SECTION SHEET METAL FLASHING AND TRIM

SECTION SHEET METAL FLASHING AND TRIM SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show

More information

DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC PLUG, CIRCULAR HERMAPHRODITIC, IN-LINE MOUNT, 2 AND 4 POSITIONS, EXPANDED BEAM

DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC PLUG, CIRCULAR HERMAPHRODITIC, IN-LINE MOUNT, 2 AND 4 POSITIONS, EXPANDED BEAM METRIC C 9 February 2015 SUPERSEDING C 23 September 2014 DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC PLUG, CIRCULAR HERMAPHRODITIC, IN-LINE MOUNT, 2 AND 4 POSITIONS, EPANDED BEAM This specification

More information

847H. Description. Features. Specifications

847H. Description. Features. Specifications 847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536

More information

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at: Optical Fiber Cable For detailed inquiry please contact our sales team at: MODEL:GYTA53 PE Jacket market@jfiber optic.com Form one single mode fiber:g.655 Characteristics Conditions Specified Values Units

More information

Termination Procedure

Termination Procedure Connector Piece Parts Contact/Connector Head Twist On Nut MX MX Boot Procedure Chart Procedure Tool Required Tool Part Number Cable Preparation & Fiber Cleaning Jacket Stripper 86710-0004 Cable Preparation

More information

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1995 Metric CSJ's 1047-03-056 & 0008-08-066 SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation

More information

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365 INCH-POUND 20 April 2016 SUPERSEDING w/amendment 2 23 February 20 DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 0 OHMS, M17/7-RG214 AND M17/7-RG36 Inactive for new design after

More information

Cable Type 125. CAI Certification Specification

Cable Type 125. CAI Certification Specification Cable Type 125 CAI Certification Specification Ref: CAI-008-C / 125 / 12-2016 Confederation of Aerial Industries Ltd Communications House 41a Market Street WATFORD Herts WD18 0PN Tel: 01923 803030 Fax:

More information

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of

More information