1 Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, RDT) Control of proportional, process and motor valves Bürkert proportional valves and flow meters are memorized 1/16 DIN size panel version Type 6223 Type Type 8012 Type 8314 Type 8417 Type 8222 Proportional Valve Globe control valve system INLINE flow sensor Pressure transmitter RTD sensor neutrino transmitter Thanks to its compact design, the universal 8611 controller is especially designed for compact control system applications. It is compatible and tested with all Bürkert proportional valves and sensors and can be connected with every nonebürkert Control valve by standard signal (, or PWMoutput). The proportional & Integral (PI) process controller is equipped with many additional functions. The process value feedback can be supplied as one of three analog inputs; a standard signal (/010V), frequency or RTD signal; directly to the universal controller. The process switching points can be set via a or signal or with the keypad. For temperature specific control, it is possible to set a cascade structure with both temperature and flow as inputs. Thanks to the proportional control capabilities, a wide range of control functions can be performed in a variety of liquids and gas medias. Fields of application: Flow control, Ratio control Pressure control control Conductivity control ph control Level control General data Materials Housing, cover Front panel folio / Screws Multipin Wallmounting holder Display Electrical connections Voltage supply cable Environment Ambient temperature Relative humidity Standards and approvals Protection class Standard EMC, CE Approvals ULRecognized for US and Canada PC, +20% glass fibre Polyester / Stainless steel CuZn, nickelplated PVC Dualline 8digit LCD with backlight Multipin: M128pin, 4pin, 3pin Insert for connecting to components according to DIN EN (previously DIN 43650, Form A). 0.5 mm 2 max. cross section, max. 100 m, shielded 0 C up to +70 C (operating and storage) 80%, without condensation IP65 EN CAN/CSAC22 No p. 1/9
2 Electrical data Power supply Power consumption Input Setpoint Standard Standard Sensors Standard Standard Frequency Input 1 Input 2 Pt100 (2 wires) Binary input Outputs Continuous signal Discontinuous signal Binary output Power supply sensor / actuator Total load of all outputs Controller modes *) PWM = pulse width modulation PTM = pulse time modulation ±10%, filtered and regulated approx. 2 W (without valve without sensor input) Sourcing mode Max. input impedance: 70 Resolution: 5.5 A Max. input impedance: 11.5 k Resolution: 2.5 mv Sourcing mode Max. input impedance: 70 Resolution: 5.5 A Max. input impedance: 11.5 k Resolution: 2.5 mv External sensor min Hz / max. 1 khz input impedance: >1 k Signal type: Sinus, square, triangle pulse (> 3000 mvpp, max. 30 Vpp) Internal Hall sensor min Hz / max. 1 khz (only with Bürkert Type S030 flow fitting) Measuring range: 0 C C Measuring current: 1 ma Measuring error: <0.5 C Input impedance: 10 k Operating threshold: 3 V30 V Max. frequency: 1 khz Standard signal max. loop resistance: 680 accuracy: 0.5% Standard signal max. current: 20 ma accuracy: 0.5% 2 transistor outputs for PWM *) or PTM *) signal Control frequency 1.2 khz20 Hz resolution max.: 16 Bit (depend from frequency) max. current load: 1.5 A switching voltage: Transistor output (PNP) (configurable) max. current load: 1.5 A switching voltage:, max. 1 A max. 1.5 A PIControl, 2 point and 3 point, cascaded Up to 2 Binary out with windows and hysteresis mode p. 2/9
3 Assembly versions 8611 Mounting on flowfitting Fittingmounting Mounting on a proportional valve Valvemounting Mounting in panel Panelmounting 8611 Mounting on a wall Wallmounting Mounting on a rail Railmounting Adaptor for Wallmounting Adaptor for Railmounting p. 3/9
4 Dimensions [mm] 8611 Fittingmounting DN [mm] H [mm] Valvemounting p. 4/9
5 Dimensions [mm] (continued) 8611 Panelmounting 54, , Wallmounting 8611 Railmounting p. 5/9
6 Connection feasibility and controller versions Assembly Flow sensor fitting mounting Wall and railmounting Valvemounting Sensor integrated HALLsensor, without external sensor input integrated HALLsensor with external sensor input without HALLsensor, with external sensor input without HALLsensor, with external sensor input Control Flow control control with flow display control with flow input for cascade control Ratio control control Pressure control Flow control control Pressure control Flow control 8pin 8pin M12 M12 8pin 8pin M12 M12 4pin 4pin 3pin 4pin 3pin 3pin 8pin M12 plug Power supply Set point value ( / ) Binary input process value output ( / ) PIcontrol output ( / ) Binary output 3pin plug Sensor input /, frequency or RDT Sensor power supply 4pin plug DIN PIcontrol output : output output / output and power supply actuator (only ) PWM output for Solenoid control valve Terminal block 1 Terminal block 2 Terminal block 3 Jumper 1 (NPN/PNP) Jumper 2 (NPN/PNP) p. 6/9
7 Ordering chart for universal Controller Type 8611 A controller Type 8611 consists of: for Fittingmounting an electronic module 8611 an INLINE fitting S030 (DN06 DN65) (Refer to corresponding data sheet has to be ordered separately) for Wallmounting an electronic module 8611 a wallmounting adaptor (included) for Railmounting an electronic module 8611 a railmounted adaptor (included) for Valvemounting an electronic module 8611 a proportional valve (Refer to corresponding data sheet of the proportional valve has to be ordered separately for Panelmounting an electronic module mounting brackets and 1 sealing (included) Mounting disposition externe Sensor input interne controller outputs (*) Power supply Setpoint setting Process value output Binary In/Out Fitting (Fitting S030) Wall Rail (RDT) Ratio or Temp. ( / ) Ratio (FrequencyNPN) (frequency NPN) (RDT) All sensors with standard signal ( / ) All sensors with standard signal ( / ) (frequency NPN) (RDT) All sensors with standard signal ( / ) (Fitting S030) (Fitting S030) (Fitting S030) Mounting disposition Sensor input externe controller outputs Setpoint setting Process value output Binary In/Out Proportional valve (Pt100) (frequency NPN) All sensors with standard signal ( / ) Mounting disposition Sensor input controller outputs Setpoint setting Process value output Binary In/ Out UL Recognition Panel 2 x Frequency (NPN/PNP) 1 x / 1 x RTD 2x PTM 1x / 2 x Bin Out * Either PWM/PTM or / selectable as PIcontrol output. If / selected as PIoutput, the process value isn't available. No ULRecognized p. 7/9
8 Ordering chart for accessories (has to be ordered separately) Description Positioning system 8810 for pneumatic actuators with railmount adaptor pin female right angle connector with selflocking threaded joint and 2 m molded cable (valve output) pin female right angle connector with selflocking threaded joint and 5 m molded cable (valve output) pin female right angle connector with selflocking threaded joint and 2 m molded cable (sensor input) pin female right angle connector with selflocking threaded joint and 5 m molded cable (sensor input) pin female connector, straight with snapon connection and 2 m molded cable (valve output) pin female connector, straight with snapon connection and 2 m molded cable (sensor input) pin M12 female connector, straight with screw connection and 2 m molded cable (PUR) (Power supply) pin M12 female connector, straight with screw connection, to assemble (Power supply) pin female connector, straight with 3 m cable (for connection to Positioning system 8810) pin female connector,straight with 5 m cable (for connection to Positioning system 8810) pin female connector, straight with 0.3 m wire (for connection to Positioning system 8810) pin female connector, straight with 0.6 m wire (for connection to Positioning system 8810) Ordering chart for spare parts (has to be ordered separately) Description Wallmounting adaptor Railmounting adaptor Mounting brackets (Set of 4 pieces) p. 8/9
9 Examples of applications Cascaded temperature control with process control valve Positioning system Type 8810 Process control valve Type 2712 or 2012C Flow control with process control valve Positioning system Type 8810 P RDT sensor Type 8417 P Flow sensorfitting Type S030 with Controller Type 8611 (fitting mounted version) Bloc with integrated Flow sensorfitting Type S030, Process control valve Type 2012C and Controller Type 8611 control with solenoid control valve controller Type 8611 (wallmounted version) Multi channel solution with process control valve Solenoid control valve Type 2835 RDT sensor Type 8417 with solenoid control valve *To find your nearest Bürkert facility, click on the orange box In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1109/11_EUen_ p. 9/9
Universal process controller econtrol
Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, Pt100) Control of proportional, process
More informationUniversal process controller econtrol
8 Universal process controller Type 8 can be combined with... Continuous, point, point and On/Off control Ratio control function Sensor inputs (,, frequency, RTD) Control of proportional, process and motor
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationValve Island with Electronic I/O
Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More information2/2 way Proportional Valve (motordriven)
2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More information2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span
2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital
More informationUltrasonic level measuring device, non-contact
Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB
More informationFLOWave SAW-Flowmeter
SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationExplosion proof rotary actuator - On/Off or programmable regulating actuator
Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can
More informationOEM radar transmitter, for aggressive media level measurement
OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type
More informationPaddle wheel flow controller for On/Off control
addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs
More informationType 8611 econtrol. Operating Instructions. (Valid from software version B02) Process controller and Ratio controller
econtrol Process controller and Ratio controller Operating Instructions (Valid from software version B02) We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten.
More informationma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module
/ - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:
More informationXXXX e. X d.. X X X a
The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationOptimising controls Vacuum switches
Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam
More informationPosiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationPressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that
More informationJUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver
Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationA new approach to static electricity countermeasures
Advanced intelligent Sensors NEW ELECTROSTATIC SENSOR EF-SSERIES A new approach to static electricity countermeasures Measurement of surface potentials while a production line is running Phone: 8.894.42
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationOEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)
Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors
More informationElectronic temperature switch with display Model TSD-30
Electrical temperature measurement Electronic temperature switch with display Model TSD-30 WIKA data sheet TE 67.03 Applications Machine tools Hydraulic power packs Coolant and lubrication systems Machine
More informationMiniature resistance thermometer Model TR33, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,
More informationTemperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.
SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples
More informationConductivity sensor for hygienic applications
Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications
More informationScrew-in resistance thermometers with plug connector
Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available
More informationProportional Directional Control Valves Size 6
Proportional Directional Control Valves Size 6 Direct controlled, electrically adjustable Interface to DIN 2 30 and ISO 0 PN [p max. ] = 35 bar 750055.06.02.06 Description (standard units) Design The proportional
More informationPosiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationProportional Directional Control Valves Nominal sizes 16 and 25
Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design
More informationDistance Sensors BOD 26K.... with optional Master-Slave-Mode
Distance... with optional Master-Slave-Mode Laser Distance The Balluff distance sensor not only detects the presence of objects, but can also indicate their precise position or location. This means the
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion
More informationAbsolute Encoders Multiturn
The Sendix F36 multiturn with the patented Intelligent Scan Technology is an optical multiturn encoder in miniature format, without gears and with 00% insensitivity to magnetic fields. With a size of just
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationIBV 100/EXE 100 Interpolation and Digitizing Electronics
Linear Encoders Angle Encoders IBV 1/EXE 1 Interpolation and Digitizing Electronics Rotary Encoders 3-D Touch Probes Position Display Units Numerical Controls HEIDENHAIN linear, rotary and angle encoders
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More information5-step-switch for adjustment of sensitivity (switching threshold) LED (super-bright, yellow) for switching state indication.
D-LAS Series D-LAS-24/90-ED-(16)-AC-T (Glass Pane Detection) - Collimated laser beam (
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology
More informationTemposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.
R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH 25 7600 mm Perfect data processing 0.5 μm Rugged industrial sensor Linear and absolute measurement LEDs for sensor
More informationTechnical Information itemp TMT180
TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationPressure transmitter for general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology
More informationElectronically controlled proportional pressure regulating valves
Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..
More informationSALES SERVICE +358 (0)
SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationSauter Components
R 44.488/ QRK 0: Heating controller Used in conjunction with temperature detectors (Ni000) and appropriate control valves for heating and domestic-hot-water control (with various configurations), mainly
More informationPNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.
PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic
More informationInsertion Flow sensor for continuous flow measurement
Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationElectronic Pressure Switch Type MEP
MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output
More informationResistance thermometer Model TR31, miniature design
Electrical temperature measurement Resistance thermometer Model TR31, miniature design WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationEPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20
89 220/101 ED EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES EPA-M1** single solenoid EPA-M2** double solenoid EPA-M3** 2 independent channels single solenoid valves RAIL MOUNTING TYPES: DIN
More informationHeavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e
Sendix H00 (shaft) The Sendix encoder H00 is an extremely rugged available in 3 versions: encoder with or without speed switch and double encoder. Thanks to the special HD-Safety-Lock construction it is
More informationDUK COMPACT ULTRASONIC FLOWMETER
DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max
More information5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication
D-LAS Series D-LAS-34-ED-25x2-AC-T (Glass Pane Detection) - Collimated laser beam (
More informationULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement
ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More informationOEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)
Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors
More informationREMOTE SENSOR SERIES. Description
REMOTE SENSOR SERIES Telco s remote sensor series can always be depended on to do the job. Although simple in design and modest in size, nothing performs more reliably in hostile environments and challenging
More informationProportional Directional Control Valves Size 6
Proportional Directional Control Valves Size 6 Direct operated, positioncontrolled Interface to DIN 2 30 and ISO 0 PN [p max. ] = 35 bar 75079.06.03.06 Description (standard units) Design The proportional
More informationGRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)
GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers, preassembled systems Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP) Table of contents 1. Product introduction 3 measuring amplifier and controller
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationD-LAS Series D-LAS2-LC-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-LC-T.
D-LAS Series D-LAS-LC-... - Visible laser beam (
More informationAbsolute Encoders Multiturn
Absolute Encoders Multiturn Functional Safety, optical The absolute multiturn encoders Sendix 5863 SIL and 5883 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN
More informationDial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis
More informationEndress Hauser. SmarTec M CLD 133 Conductivity Measurement
Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationXXXX e. X d.. X X X a
The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationTURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)
A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections