Series 01 Type 01, 02

Size: px
Start display at page:

Download "Series 01 Type 01, 02"

Transcription

1 Series 01 Type 01, 02 ThermalProtectors

2 ThermalProtectors for nominal currents up to 2.5 Series 01 Type 01 Type 02 Version C, S, L, N Benefits & dvantages The outstanding quality level of our ThermalProtectors of the Series 01 satisfies highest demands for safety and reliability. They are provided with a patented, fully developed and reliable switching device system. Compact & Pressure Stable - Ideal for installation in limited space, very suitable for mounting into and onto windings Safe, Reliable & Durable - Constant contact pressure over the whole temperature range - Over 70 tests conducted during the production process ensure reliability - pprovals world-wide - Very fast switching; therefore short arcing influence on the contacts Temperature-sensitive - Reproducible SwitchingTemperature induced by mechanical unstressed and electrically unloaded bimetal disc - Factory-adjusted NominalSwitchingTemperature (NST) Fast - Excellent thermal coupling induced by a small-scaled, low-weighted switching device Flexible - Wide-band mains supply range - Extremely large assortment of lead-wires and solid wires available for connection General data T T Functions & Types C01 S01 L01 N01 CK1 SK1 LK1 NK1 C02 S02 L02 N02 Max. pressure stability (housing) / (max. mechanical load) 450 N (45kg) High-Voltage Insulation (HiPot) Version C -- Version S 2 kv Version L 2 kv Version N -- Suitable for installment in protection class (insulation) I (1), ll (2) Degree of protection IPOO Impregnation resistance suitable Contact bounce time [ms] < 1 Contact resistance (acc. to MIL-Standard R 5757) [m ] < 50 Vibration proof (at Hz) [m/s2] 100 (10g) ResettingSwitchingTemperature Range RST dependant on Series please inquire - - Standard [ C] -- > 35 - UL-Standard Range [ C, K] NST -30 ±15 - CS-Standard Range [ C, K] NST NST -50 NST = NominalSwitchingTemperature, see technical data RST = ResettingSwitchingTemperature Normally closed (NC), Resetting, Standard Normally open (NO), Resetting, Standard Bimetal switch fter reaching its factory-adjusted NominalSwitching Temperature (NST) the bimetal disc suddenly turns over from its stable initial position into a stable end position and thereby activates the switching device. Normally closed (NC) Contacts open and switch off the supply => direct disconnection (01) Normally open (NO) Contacts close and activate the supply => i.e. switching on of signal units (02) Resetting after cooling down to below its factory-adjusted ResettingSwitchingTemperature (RST) the switching device suddenly snaps back into its initial position Max. Switching current Imax Maximum current in disturbed condition => i.e. during short circuit or on locked-rotor condition You develop a successful product we provide you with the appropriate ThermalProtector. Whether you want to develop a new product or if you want to attain the highest quality standards in your production do not compromise! Our Know-How as well as our wide range of products will set you no limits. Standard or special solution You develop innovative concepts we provide you with suitable thermal protection. Our exceptionally large standard programme already offers you a multitude of choices. Furthermore, we offer specific solutions which are developed in our laboratories to meet your special requirements. Thereby you can take advantage of more than 35 years of experience in product development achieved in close cooperation with wellknown producers in various industries. Individual solutions are our speciality - challenge us! T cc. to Thermik Test For others please inquire Subject to change

3 Technical Data The listed specifications and information are based on tests and test series. They are of a standard nature and therefore deviations may occur in connection with specific applications. The suitability for a specific application must be individually tested by the user. Please contact us for advise and support. Version C01, CK1 and C02 are the basis for the following variations. Standard version is without base insulation - Multi-purpose usability - Optimal thermal coupling of the switching device - Live contact of housing therefore - when fitting - base insulation has to be provided. S01, SK1 and S02 are provided with an insulation cap for base insulation - Various types with different insulation materials and protection classes available - Suitable for mounting into and onto windings of electro-motors, transformers or ballasts. C01 C02 S01 S02 K1= 01 for the lower temperatures Switching contact type NC = normally closed, NO = normally open Insulated: insulation cap Version S Temperature NominalSwitchingTemperature (NST), in 5K-steps [ C] Tolerance range Standard- Tol [K] Voltage Rated voltage Un 50/60 Hz [V C ] Max. C-operating voltage range up to... [V C ] Max. DC-operating voltage range up to... [V DC ] Current / Switching Cycles Rated current In 50/60 Hz t Un: ohmic - cos = 1.0 [] / [n] t Un: inductive - cos = 0.6 [] / [n] L t Un: inductive - cos = [] T t 500 V C : ohmic - cos = 1.0 [] / [n] T t 500 V C : inductive - cos = 0.6 [] / [n] T Max. switching current Imax at Un - cos = 1,0 [] / [n] pprovals NST: 70 C-180 C, K1: 60 C-180 C VDE/IEC NST: 60 C-200 C UL NST: 70 C-200 C, K1: 60 C-200 C CS/cUL NST: 70 C-180 C BEB NST: 70 C-180 C SEMKO L pprovals for Ballasts Dimensions (Standard) NC NO NC NO (VDE,IEC,BEB,SEMKO,CS) 277 (UL) 250 (VDE,IEC,BEB,SEMKO,CS) 277 (UL) /10,000 (VDE,IEC,BEB,SEMKO) 2.5/10,000 (VDE,IEC,BEB,SEMKO) 1.6/10,000 (VDE,IEC,BEB,SEMKO) 1.6/10,000 (VDE,IEC,BEB,SEMKO) 1.8 (VDE,IEC) 1.8 (VDE,IEC) 5.0/2,000 dependant on version (RST, insulation etc.) acc. to inquiry 5.0/2,000 Diameter Ød [mm (inch)] Overall height (with standard connection) h [mm (inch)] Length Insulation cap (S) l [mm (inch)] feasible wiring connections Lead wire Single wire Standard wiring connection 9.0 (.354) 9.0 (.354) 4.3 (.169) 4.3 (.169) Lead wire: 0.25 mm 2 /WG (.370) 9.4 (.370) 4.8 (.189) 4.8 (.189) 16 (.630) 16 (.630) Lead wire: 0.25 mm 2 /WG 22 T cc. to Thermik Test For others please inquire Yes No / not applicable Subject to change

4

5 Typical current sensitivity characteristics special feature of the Series 01 is that the switch is a temperature-sensitive switch. In normal operation and loads up to nominal current, self-heating of the switch is extremley low. Therefore the lowering of the switching temperature caused by self-heating will be within the NominalSwitchingTemperature tolerance. Please also refer to Benefits & dvantages. Standards: pprovals Please always list the needed approvals separetely onto your order. VDE acc. to EN ENEC acc. to IEC How to order CB-Report acc. to IEC (IEC 730) UL acc. to UL 2111 UL 873 CS acc. to C22.2 Features of automatic action acc. to IEC/EN 60730: 2B/2C/2BM/2CM. Existing Standard mendments acc. to IEC/EN 60730: -1; -2-1; -2-3; CC- CENELEC Certification greement acc. to EN Thermik products correspond to the respective EU-directives / rules BEB acc. to EN SEMKO acc. to EN CQC acc. to IEC Use the quality of our products to safeguard the quality of your products. From the first stage of production until delivery our products undergo more than 70 quality inspections. Specially designed, fully automatic control devices guarantee an optimal quality standard. Needless to say, these high demands are met on all our production sites. Single switch Duplex configuration Triplex configuration Ready Reckoner 1 mm <=> inch (") 25.4 mm <=> 1 inch (") 100 mm <=> 3.94 " 300 mm <=> " C <=> ( F - 32) / 1.8 F <=> x C It s good to know - that our quality and flexibility open up a whole new range of possibilities to you. Order samples Single with L1= L2 Single with L1= L2 Duplex L1 - L3 Triplex L1 - L4 NominalSwitchingTemperature (NST) [ C] Tolerance Range [ ± K] Lengths [mm] Version Type L1 S L2 L / 0200 L3 C / 0100 / 0200 L4 S / 0180 / 0180 / 0650 L1 L2 L3 L4 Thermik produces the smallest thermal protectors available on the market and in addition PTC Thermistor sensors in miniature design for rounding up the product range for use in your compact products. We also offer a unique variety of technical solutions our standard programme alone comprises of more than 2000 models with connecting wires in different lengths, colours, cross-sections and insulation materials. Subjekt to change

6 Thermik Design concept and aims to suit customers Competence is our asset For more than 35 years the name Thermik has stood for efficiency, flexibility and reliability in the production of Thermal protectors. We combine experience and Know-How with innovation and consistent orientation towards the objectives of our customers. In this way we constantly extend and improve our range of products. nd if on occasion your requirements cannot be fulfilled by our standard programme, we develop a customized solution together with you. Our highly qualified and competent employees put your wishes into effect. Irrespective of where you are manufacturing we supply all over the world. Our subsidiaries in Germany, Malaysia and US are all equally equipped production sites and their machinery fulfils the highest standards. We are therefore well prepared for the efficient production of large and small quantities. This flexibility guarantees you highest supply reliability. worldwide net of representatives offers you specialist advice on site. Our products have all the internationally required approvals. We continuously optimise materials, working processes and production materials. Safety, Quality and Customer Requirements have the highest priority. dditional brochures informing you of other products within product range are available on request. Thermik Geraetebau GmbH Im ltgefaell 8 D Pforzheim POBox D Pforzheim Tel Fax info@thermik.de DIN EN ISO 9001 Thermik is world-wide with all its production sites certified to DIN EN ISO 9001 Certificate Register No Certificate Register No TMS Challenge us with your requirements - we will show you the solutions! marketing concept Rev /4 2,500

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Tested and ready to use Quality from a single-source

Tested and ready to use Quality from a single-source Tested and ready to use Quality from a single-source 2 Cable fabrication 100% tested and ready to use for all-round certainty Quickly assembled and reliable in operation that is how machine components

More information

TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS

TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS In touch with the medium TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS 2 www.bedia.com CONTENT The company

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 C O M P O N E N T S The UR26, UR36 & UR40 are DC high-speed current limiting air Circuit-Breakers, trip free, single pole, bi-directional,

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Product Data Sheet 3252J/2H3PU

Product Data Sheet 3252J/2H3PU 3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Product Data Sheet 3254 J/2H3P

Product Data Sheet 3254 J/2H3P 3254 J/2H3P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3

More information

Libra A. Unique Characteristics

Libra A. Unique Characteristics Unique Characteristics Laminar Heatsink Designed and internationally patented by ATP to maximize the lifespan of our new generation of high performance LED luminaires. Comfort Diffuser Diffuser designed

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1)

Page 2 of 69 VDE Report No.: / DC - DC Converter for building in. TDK Innoveta Inc. iba - Series (see model matrix appendix 1) Page 2 of 69 VDE Report No.: 2520400-3336-0009/132550 Test item description... : Trade Mark...: Manufacturer...: Model/Type reference...: Serial Number..: Ratings...: Input: Output: Ambient: DC - DC Converter

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION Single-Phase Low Voltage Dry- Type Transformers 5-400 kva Three-Phase Low Voltage Dry- Type Transformers 7.5-1000 kva TECHNICAL INFORMATION TABLE OF CONTENTS Introduction...3 Technical Explanations...4

More information

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 8452/2HHP. The engineer's choice Product Data Sheet 8452/2HHP The engineer's choice 8452/2HHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

Interference Suppression PCX2 337 film capacitors

Interference Suppression PCX2 337 film capacitors MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5 mm QUICK REFERENCE DATA Capacitance range (E6 series) * 0.01μF to 3.3μF Capacitance tolerance ± 10 %, ± 20 % Rated (AC) voltage 50 to 60 Hz 275 V

More information

Product Data Sheet 8452/2 GHHP

Product Data Sheet 8452/2 GHHP 8452/2 GHHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3

More information

Schutzeinrichtungen. Safety fence system HIGH RESISTANT

Schutzeinrichtungen. Safety fence system HIGH RESISTANT Schutzeinrichtungen Safety fence system HIGH RESISTANT Safer than safe Brühl Safety guards Our promise Reliably safeguarding people and machinery: This is the principle that we have always remained committed

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Snap Action Switches Technical Guide

Snap Action Switches Technical Guide These basic principles apply to all our precision switches. The specific characteristics of each model are given in more detail in the relevant production sections. Switch construction Single-pole changeover

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New) XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

MADE IN GERMANY INDUSTRIAL ENAMELLING DIES

MADE IN GERMANY INDUSTRIAL ENAMELLING DIES INDUSTRIAL ENAMELLING DIES MADE IN GERMANY Headquarter Euromicron Group Frankfurt a. M. Dear valuable Customer, engine design, measuring technology, or textile industry for almost every industry segment

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

HARTING Coaxial and Metric Connectors

HARTING Coaxial and Metric Connectors HARTING Coaxial and Metric Connectors HARTING Worldwide Transforming customer wishes into concrete solutions The HARTING Technology Group is skilled in the fields of electrical, electronic and optical

More information

PSR-SCP- 24DC/ESD/5X1/1X2/300

PSR-SCP- 24DC/ESD/5X1/1X2/300 Extract from the online catalog PSR-SCP- 24DC/ESD/5X1/1X2/300 Order No.: 2981428 Safety relay with adjustable delay time 0-300 s, screw version Commercial data EAN 4017918975227 Pack 1 pcs. Customs tariff

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Inductive Standard Displacement Transducers

Inductive Standard Displacement Transducers WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features MDEX Torque transducer CS-T-04-MDEX Special features - Explosion proof acc. to ATEX 95 - Exx II 2 G Ex deq IIC T4 - Nominal (rates) torque of 100kNm, 130kNm and 150kNm - HBM Accuracy Class 0,1 - Digital

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New) XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Class l, Division 1 Group A-D IIC T4 As our products are continuously improved, we reserve the right to make any change in the stated

More information

The Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04

The Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04 The Best Relaytion Cradle Relay W 08-9803 Rev. B EC-JM00-0009-03 ECOC: JM0. Aug. 0 Hand solder and plug-in relay, for AC operation, non-polarized, non-latching Features highly reliable great variety of

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Transformers & Inductive Components

Transformers & Inductive Components Transformers & Inductive Components Catalogue 15 The Company Since its foundation in 1979 DANTRAFO Group has grown to become one of the leading manufacturers of transformers and inductive components in

More information

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

DC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series

DC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series / Converter FEATURES 6W,Ultra wide input, isolated & regulated dual/ single output, DIP package, - converter CB Patent Protection RoHS Wide range of input voltage (4:1) Efficiency up to 88% No-load power

More information

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms Compact size and 3A power relays for energy management and industrial equipment HE-S RELAYS New TYPICAL APPLICATIONS Photovoltaic power generation systems (Solar inverter) Uninterruptible Power Supplies

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

Interference Suppression Film capacitors

Interference Suppression Film capacitors MKP RADIAL POTTED CAPACITORS Pitch 10.0/15.0/22.5/27.5mm 10 and 15mm 22.5 and 27.5mm QUICK REFERENCE DATA Capacitance range (E6 series) * Capacitance tolerance Rated (AC) voltage 50 to 60 Hz Climatic category

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER190-39/14/2TDMO RER190-39/14/2TDMO INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data...

More information

Instruction manual for STA 1 sectional door operator

Instruction manual for STA 1 sectional door operator Instruction manual for STA 1 sectional door operator Sectional door operator STA 1 / Rev. 0.3 1 GB 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

XUA1 - AC Voltage and phase balance relay

XUA1 - AC Voltage and phase balance relay XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of

More information

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt

ISOMETER IR Headline. Version V004. Vorläufiges Datenblatt Headline ISOMETER IR155-4210 Sub-Headline Insulation monitoring device (IMD) for unearthed charging systems (IT systems), for e.g. electric vehicles Version V004 Vorläufiges Datenblatt TDB106035en / 06.2012

More information