Name Version Date Author Summary of changes NMR File format /7/2014 Rashmi R Draft version
|
|
- Chloe Chandler
- 5 years ago
- Views:
Transcription
1 Name Version Date Author Summary of changes NMR File format /7/2014 Rashmi R Draft version
2 #NMR NMR A00 L1 A00 M X1 HD_A00_STANDARD_HEADER NMR S59 LI S59 O X1 RT_S59_ACCEPT_SUPPLY_PT_ENQUIRY NMR S59 L2 S70 M X500 RT_S70_ADDRESS NMR S59 L3 S75 M X100 RT_S75_METER_POINT_DETAILS NMR S59 L4 S98 O X100 RT_S98_SMART_DATA NMR S59 L4 Q44 O X1 RT_Q44_CSEP INFORMATION NMR S59 L4 Q51 O X1 RT_Q51_CONSUMPTION INFORMATION NMR S78 L1 S78 O X1 RT_S78_REJECT_SUPPLY_PT_ENQUIRY NMR S78 L2 S72 O X15 RT_S72_REJECTION_DETAIL NMR S78 L2 S68 M X500 RT_S68_ENQUIRY_METER_POINT NMR S78 L3 S72 O X15 RT_S72_REJECTION_DETAIL NMR S64 L1 S64 O X1 RT_S64_OFFER_DETAILS NMR S64 L2 S70 M X500 RT_S70_ADDRESS NMR S64 L3 S75 M X100 RT_S75_METER_POINT_DETAILS NMR S64 L4 K12 M X1 RT_K12_MAM_GAO_DETAIL NMR S64 L4 K14 M X1 RT_K14_ADDTNL_METERING_DETS NMR S64 L4 S98 O X100 RT_S98_SMART_DATA NMR S64 L2 Q44 O X1 RT_Q44_CSEP INFORMATION NMR S21 L1 S21 O X1 RT_S21_CUR_SP_NOM_REJ_OR_REF NMR S21 L2 S72 O X15 RT_S72_REJECTION_DETAIL NMR S21 L2 S69 M X500 RT_S69_NOMINATION_METER_POINT NMR S21 L3 S72 O X15 RT_S72_REJECTION_DETAIL NMR S22 L1 S22 O X1 RT_S22_NEW_SP_NOM_REJ_OR_REF NMR S22 L2 S72 O X15 RT_S72_REJECTION_DETAIL NMR S22 L2 S69 M X500 RT_S69_NOMINATION_METER_POINT NMR S22 L3 S72 O X15 RT_S72_REJECTION_DETAIL NMR S23 L1 S23 O X1 RT_S23_NOMINATION_CANCELLTN NMR S23 L2 S72 O X15 RT_S72_REJECTION_DETAIL NMR Z99 L1 Z99 M X1 TR_Z99_STANDARD_TRAILER
3 A code identifying the ytpe of request that this record represents. VALUE : A00 ORGANISATION_ID M N 10 0 A reference, which uniquely identifies a Customer/Organisation FILE_TYPE An application specific code used to identify the structure and usage of the file: NMR CREATION_DATE M D 8 0 CREATION_TIME M M 6 0 GENERATION_NUMBER M N The date on which the file was generated. The date format is 'YYYYMMDD' The time at which the file was generated (within the Creation Date), The time format is 'HHMMSS' A sequence number which represents an issue of a file from the System User (indficated by the organisation ID), and, of the file type (indicated by file type) e.g. The first Nominations file from an System User will have the number 1, the second, number 2 etc. Each file sent either from a System User to Transco or from Transco to System User within one file type must have consecutive numbers.
4 A code identifying the type of request that this record represents. Value S59 NOMINATION_SHIPPER_REF A reference supplied by the System User when making O T 30 0 a Nomination. NOMINATION_ENQUIRY_TYPE Indicates that the enquiry is for a current live supply point or for M T 1 0 a new aggregation of meter points. MINIMUM_MRF_TYPE_CODE O T 1 0 A code identifying a valid meter reading frequency. CURRENT_DM_SOQ The maximum rate of gas flow (measured in KWH) for a gas day (which commences at 06:00 hours) for the Daily Metered (DM) Portion of the Supply Point. CURRENT_DM_SHQ BOTTOM_STOP_DM_SOQ The maximum hourly rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point. The minimum acceptable rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point on a gas day (which commences at 06:00 hours) NDM_SOQ_ROLLING The maximum rate of gas flow (measured in Kwh), for the Non Daily Metered (NDM) portion of the Supply Point, as derived by the transporter for Class 3 and 4 NDM_SOQ_BILLING The maximum rate of gas flow (measured in Kwh), for the Non Daily Metered (NDM) portion of the Supply Point, as calculated for Class 3 and 4 NDM_EZC_ROLLING The Exit Zone Capacity for the Non Daily Metered (NDM) portion of this Supply Point. EXIT_ZONE_IDENTIFIER A unique reference for the Exit Zone. LDZ_IDENTIFIER M T 4 0 Unique reference code for the Local Distribution Zone (LDZ). END_USER_CATEGORY O N 10 0 A unique reference for the End User Category. SUPPLY_POINT_CATEGORY Describes the size of the Supply point in terms of Gas M T 5 0 Nomination NO_OF_DATALOGGERS O N 3 0 The number of DataLoggers installed at the Supply Point. SUPPLY_TYPE_CODE A code which identifies whether the gas is to be delivered Firm M T 4 0 or Interruptible. RECORDED_DATE RECORDED_TIME M D 8 0 M M 6 0 The date on which the original request was recorded on TransCo's System. The time at which the original request was recorded on TransCo's System. CURRENT_YEAR_MIN_SOQ Replaces bottom stop SOQ. This is applicable for Class 1 and M N 8 0 Class 2 sites only. DNI_INDICATOR O T 1 0 WITHDRAWAL_STATUS Y is set if the there is no shipper is associated with this site or if M T 1 0 a Withdrawal request has been accepted from the registered Shipper. N otherwise. SUPPLY_POINT_CLASS M N 1 0 It defines the class type for the supply meter point. PREVAILING_METER_READ_BATCH_FREQUENCY The frequency on which reads will be sent for class3 supply O T 1 0 meter points. 117
5 A code identifying the type of request that this record represents. Value:S70 BUILDING_NUMBER O N 4 0 Building Number as defined in PAF. SUB_BUILDING_NAME O T 30 0 Sub Building Name as defined in PAF BUILDING_NAME O T 50 0 Building Name as defined in PAF. PRINCIPAL_STREET A combination THOROUGHFARE NAME and O T 35 0 THOROUGHFARE DESCRIPTOR as defined in PAF. DEPENDENT_LOCALITY A named, geographically defined area within a POST O T 35 0 TOWN area (a Postal District). POST_TOWN O T 35 0 The post town in which the street lies. POSTCODE_OUTCODE M T 4 0 Standard PAF outcode as defined in the PAF digest. POSTCODE_INCODE M T Standard PAF incode as defined in the PAF digest.
6 S75_METER_POINT_DETAILS OUTBOUND Field Name Optionality Domain Length Decimal Description A code identifying the type of request that this record represents. VALUE : S75 METER_POINT_REFERENCE An unique identifier for the point at which a meter is, M N 10 0 has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Meter Point References will only be created for new services or when a service is relayed to a different position. CONTEXT: A Meter Point which is part of a Supply Point in the Competitive Market. Supplied in conjunction with the Postcode as a cross-check to ensure the correct Reference has been provided. METER_LOCATION_CODE An entity used to define the location of a meter, eg in M N 2 0 the meter box, in house, in garage, in cellar etc. The detail held in this entity must be sufficient to allow a meter reader to identify and read a specific meter within a site. METER_SERIAL_NUMBER The manufacturers meter serial number as held in M T 14 0 physical meter. GAS_NOMINATION_TYPE_CODE This defines whether the supply meter point is DM,NDM or DME. METER_POINT_AQ_ROLLING M N 12 0 Annual quantity value for the supply meter point. METER_POINT_AQ_FORMULA_Y Annual quantity value for the supply meter point. M N 12 0 EAR DATA_LOGGER_SERIAL_NUMBE The manufacturers datalogger serial number as held O T 14 0 R in current GTI including embedded spaces. DATA_LOGGER_UNIQUE_NUMBE R O N 10 0 A system Generated number allocated to each individual datalogger record within a datalogger location to provide unique identification. METER_LINK_CODE A code enabling the functional relationship between O T 1 0 meters (the way in which they are linked together) at given locations. CORRECTION_FACTOR This is a fixed factor based on O N 9 6 pressure/altitude/temperature OPERATIONAL_STATUS O D 8 0 NA MET_METER_MECHANISM This defines the type of the meter.it can be credit, prepayment etc. NUMBER_OF_DIALS_OR_DIGITS M N 2 0 Number of dial for the meter PREVIOUS_SUPPLIER AMR_INDICATOR O T 12 0 M T DEFINITION: An unique short code which gives the identity of the previous supplier for the meter point. CONTEXT: Populated only when output in conjunction with an RT_S15_TRANSFER_OF_OWNERSHIP. Indicator to identify whether the site has AMR attached,
7 RT_S98_SMART_DATA OUTBOUND Field Name Optionality Domain Length Decimal Description DEFINITION: A code identifying the type of request that this record represents. VALUE: S98 METER_POINT_REFERENCE A unique identifier for the point at M N 10 0 which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Meter Point references will only be created for new services or when a service is relayed to a different position SMSO_ID The identity of the operator, a O T 3 0 Supplier has procured data and communication services from, in respect of a Smart Metering System. SMSO_EFD The date on which the Smart Meter O D 8 0 System Operator becomes effective. FORMAT : YYYYMMDD DCC_SERVICE_FLAG A DCC provided flag to indicate the O T 1 0 status of the services being provided by the DCC to a Meter. Allowable values: A Active S Suspended W Withdrawn DCC_SERVICE_FLAG_EFD The first inclusive calendar date for O D 8 0 which the status of the DCC Service flag applies. FORMAT : YYYYMMDD IHD_INSTALL_STATUS Information from the Supplier O T 1 0 regarding the status/existence of the In Home Display at a metering point. Allowable values: I Installed E Existing D Declined FIRST_SMETS_INSTALLATION_D ATE UNIQUE_PROPERTY_REF_NO NETWORK_OWNER_ID NETWORK_OWNER_ID_EFD O D 8 0 O T 12 0 O T 3 0 O D First SMETS Meter Installation date for a Meter Point Reference provided by the incumbent Shipper. FORMAT : YYYYMMDD A Unique Property Reference Number (UPRN) is an attribute of a Basic Land and Property Unit (BLPU). It is a unique reference number that can be linked to further address information that is collated and provided by the Ordnance Survey Group. This field will not be populated until a governance is agreed The ID of the organisation who develops, operates and maintains gas distribution network that forms part of the National Gas Network. Date the network owner is effective for that Meter Point. FORMAT : YYYYMMDD
8 A code identifying the type of request that this record represents. VALUE : Q44 ORIGINAL METER POINT AQ O N 12 0 IGT AQ (entry RPC) CSEP ID M T 8 0 Unique CSEP ID CSEP CONNECTION_MAX AQ The aggregated annual consumption of the CSEP M N 12 0 connection used to calculate the LDZ charges. igt Transportation Rate The monetary rate that is applicable to the Supply O N 3 8 Meter Point for igt transportation charges igt Charging Methodology The igt charging methodology that is applied to the O T 1 0 Supply Meter Point. L- LEGACY/R - RPC/I - INFILL igt Transportation Rate Type O T 1 0 D- Pence Per Day / K - Pence Per Kilowatt igt Metering Rate The monetary rate that is applicable to the Supply O N 3 8 Meter Point for igt metering charges igt Infill Rate The monetary rate that is applicable to the Supply O N 3 8 Meter Point for igt infill charges IGT SHORT_CODE Short code for the igt related to the CSEP. 49
9 A code identifying the type of request that this record represents. VALUE : Q51 START_DATE M D 8 0 Consumption start date END_DATE M D 8 0 Consumption end date CONSUMPTION_VALUE M N 10 0 Consumption value for the supply meter point for a given period 29
10 A code identifying the type of request that this record represents. Value:S78 NOMINATION_SHIPPER_REF A reference supplied by the System User when O T 30 0 making a Nomination. NOMINATION_ENQUIRY_TYPE Indicates that the enquiry is for a current live supply M T 1 0 point or for a new aggregation of meter points. RECORDED_DATE RECORDED_TIME M D 8 0 M M 6 0 The date on which the original request was recorded on TransCo's System. The time at which the original request was recorded on TransCo's System. 47
11 A code identifying the type of request that this record represents. Value:S72 REJECTION_REASON M T A reason for the rejection of the original input request.
12 A code identifying the type of request that this record represents. Value:S68 METER_POINT_REFERENCE M N 10 0 An unique identifier for the point at which a meter is, has been or will be connected to the gas network. Standard PAF outcode as defined in the PAF digest. POSTCODE_OUTCODE M T 4 0 Standard PAF incode as defined in the PAF digest. POSTCODE_INCODE M T
13 A code identifying the type of request that this record represents. Value:S64 TRANSPORTER_NOMINATION_RE OFFER_NUMBER NOMINATION_SHIPPER_REF SUPPLY_TYPE_CODE M N 9 0 M N 3 0 O T 30 0 M T 4 0 A reference number which uniquely identifies the NOMINATION. A sequential number within a Nomination to uniquely identify the Offer. A reference supplied by the System User when making a Nomination. A code which identifies whether the gas is to be delivered Firm or Interruptible. MRA_REFERENCE A code which uniquely identifies a Meter Reading O T 4 0 Agency. REQUESTED_MRF_TYPE_CODE O T 1 0 A code identifying a valid meter reading frequency. MINIMUM_ACCEPTABLE_MRF_TYP O T 1 0 A code identifying a valid meter reading frequency. REQUESTED_DM_SOQ The maximum rate of gas flow (measured in KWH) for a gas day (which commences at 06:00 hours) for the Daily Metered (DM) Portion of the Supply Point. REQUESTED_DM_SHQ OFFERED_DM_SOQ The maximum hourly rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point. The maximum rate of gas flow (measured in KWH) for a gas day (which commences at 06:00 hours) for the Daily Metered (DM) Portion of the Supply Point. OFFERED_DM_SHQ BOTTOM_STOP_DM_SOQ The maximum hourly rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point. The minimum acceptable rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point on a gas day (which commences at 06:00 hours) NDM_SOQ_ROLLING The maximum rate of gas flow (measured in Kwh), for the Non Daily Metered (NDM) portion of the Supply Point,as derived by Transco. NDM_SOQ_BILLING The maximum rate of gas flow (measured in Kwh), for the Non Daily Metered (NDM) portion of the Supply Point, as calculated for Class 3 and 4 NDM_EZC_ROLLING The Exit Zone Capacity for the Non Daily Metered (NDM) portion of this Supply Point. EXIT_CAPACITY_LDZ_ECN M N 10 4 NTS_COMMODITY_CHARGE M N 10 4 LDZ_CUSTOMER_CHARGE M N 10 4 LDZ_COMMODITY_CHARGE M N 10 4 LDZ_CAPACITY_CHARGE O N 10 4 EXIT_ZONE_IDENTIFIER A unique reference for the Exit Zone. LDZ_IDENTIFIER Unique reference code for the Local Distribution Zone M T 4 0 (LDZ). END_USER_CATEGORY O N 10 0 A unique reference for the End User Category. SUPPLY_POINT_CATEGORY Describes the size of the Supply point in terms of Gas M T 5 0 Nomination TNI_INTERRUPTIBLE_DAYS O N 3 0 RECORDED_DATE M D 8 0 The date on which the original request was recorded on TransCo's System. RECORDED_TIME M M 6 0 The time at which the original request was recorded on TransCo's System. Current Year Minimum SOQ DM only SUPPLY_POINT_CLASS O N 1 0 It defines the class type for the supply meter point. METER_READ_BATCH_FREQUENC O T 1 0 LDZ_SHORTHAUL_CHARGE O N 10 4 NTS_SHORTHAUL_CHARGE O N 10 4 ADDITIONAL_COMMENTS O T DNI_INDICATOR O T 1 0 TERMINAL_NUMBER O T 9 0 The frequency on which reads will be received for class3 supply meter points. Terminal Number is to be provided to enable the calculation of the NTS Shorthaul charges. Seasonal LSP Indicator O T 1 0 Seasonal LSP indicator.allowable Values: Y/N 422
14 A code identifying the type of request that this record represents. Value:S21 OUTCOME_CODE Details whether the request has been rejected or referred by Transco M T 2 0 NOMINATION_SHIPPER_REF A reference supplied by the System User when O T 30 0 making a Nomination. SITE_WORKS_REFERENCE O N 9 0 The unique reference of a Site Works Quote. APPEALS_REFERENCE O N 9 0 The unique reference of a Site Works Quote. REQUESTED_DM_SOQ The maximum rate of gas flow (measured in WH) for a gas day (which commences at 06:00 hours) for the Daily Metered (DM) Portion of the Supply Point. REQUESTED_DM_SHQ The maximum hourly rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point. MRA_REFERENCE A code which uniquely identifies a Meter Reading Agency. O T 4 0 MRF_TYPE_CODE A code identifying a valid meter reading frequency. O T 1 0 TRANSPORTER_NOMINATION_RE A reference number which uniquely identifies the NOMINATION. RECORDED_DATE RECORDED_TIME CSEP Information igt Network Charges SUPPLY_POINT_CLASS O N 9 0 M D 8 0 M M 6 0 O T 1 0 O T 1 0 M N 1 0 The date on which the original request was recorded on TransCo's System. The time at which the original request was recorded on TransCo's System. (igt sites only) Request for CSEP Information Y (yes) or (No) (igt sites only) Request for IGT Network Charges Y (yes) or (No) It defines the class type for the supply meter point. METER_READ_BATCH_FREQUENC The frequency on which reads will be received for O T 1 0 class3 supply meter points. LDZ_SHORTHAUL O T 1 0 Request for LDZ Shorthaul charges, Y or N NTS_SHORTHAUL O T 1 0 Request for NTS Shorthaul charges, Y or N TERMINAL_NUMBER Terminal Number is to be provided to enable the O T 9 0 calculation of the NTS Shorthaul charges. ADDITIONAL_COMMENTS O T
15 A code identifying the type of request that this record represents. Value:S69 METER_POINT_REFERENCE POSTCODE_OUTCODE POSTCODE_INCODE GAS_NOMINATION_TYPE_CODE M N 10 0 M T 4 0 M T 4 0 O T An unique identifier for the point at which a meter is, has been or will be connected to the gas network. Standard PAF outcode as defined in the PAF digest. Standard PAF incode as defined in the PAF digest. A code to indicate which portion of the Supply Point the Meter Point belongs.
16 A code identifying the type of request that this record represents. VALUE : K12 GAS_ACT_OWNER CURRENT_MAM_ABBREVIATED_NA ME PROSPECTIVE_MAM_ABBREVIATED _NAME M T 1 0 Unique code which identifies the role the market participant is acting in. Allowable values : T - GAO Transporter, S - GAO Supplier, C - GAO Consumer O T 12 0 Current meter asset manager abbrevated name O T 12 0 Prospective meter asset manager abbrevated name PROSPECTIVE_MPR_EFFECTIVE_DA TE O D The date on which Meter Asset Manager is effectively responsible for the meter assets at the meter point.
17 DEFINITION: A code identifying the type of request that this record represents. VALUE: K14 METER_TYPE DEFINITION: The type of meter. O T 1 0 Values.R = Rotary.T = Turbine.D = Diaphragm of unknown material.l = Leather Diaphragm.S = Synthetic Diaphragm.U = Ultrasonic.Z = Unknown METER_MODEL_NAME DEFINITION: The model description for the O T 10 0 meter (e.g. "U6", "U16","102M12" or "G2500"). METER_MANUFACTURER DEFINITION: The code of the manufacturer of O T 3 0 the meter. METER_MANUFACTURED_YEAR DEFINITION: The year in which the meter was O N 4 0 manufactured expressed as a century date (e.g. 1981). IMPERIAL_METER_INDICATOR DEFINITION: Indicator identifying if the meter O T 1 0 measures volume of gas consumed in metric or imperial units. Allowable values when present:- Y = Imperial meter N = Metric meter METER_READING_UNITS DEFINITION: This contains the units the meter O N 5 0 is read in e.g. 10,100, 1000 Cubic Feet CORRECTOR_MODEL_NAME DEFINITION: The model description for the O T 10 0 meter (e.g. "U6", "U16", "102M12" or "G2500"). CORRECTOR_MANUFACTURER DEFINITION: The code of the manufacturer of O T 3 0 the corrector. CORRECTOR_MANUFACTURED_ YEAR O N 4 0 DEFINITION: The year in which the meter was manufactured expressed as a century date (e.g. 1981). CORRECTOR_CORRECTED_REA DING_UNITS O N 5 0 CORRECTOR_UNCORRECTED_R EADING_UNITS O O DEFINITION: This contains the units the corrected corrector reading reads in, eg 10s, 100s, 1000s cubic feet. DEFINITIONS: This contains the units the uncorrected corrector reading reads in, eg 10s, 100s, 1000s cubic feet.
18 A code identifying the type of request that this record represents. VALUE : S22 OUTCOME_CODE Details whether the request has been rejected or referred M T 2 0 by Transco VALUES : RJ - Rejected, RF - Referred NOMINATION_SHIPPER_REF O T 30 0 A reference supplied by the System User when making a Nomination. It may be used by the System User to identify the Nomination and any subsequent Confirmation made for that Nomination. SITE_WORKS_REFERENCE O N 9 0 The unique reference of a Site Works Quote. APPEALS_REFERENCE O N 9 0 A unique reference for a Capacity Appeal. NEW_AGGREGATION_REASON The reason why the new aggregation of meter points is M T required. REQUESTED_DM_SOQ The maximum rate of gas flow (measured in KWH) for a gas day (which commences at 06:00 hours) for the Daily Metered (DM) Portion of the Supply Point. CONTEXT: The new rate of gas flow deemed to be required by the Customer in the future. REQUESTED_DM_SHQ MRA_REFERENCE O T 4 0 The maximum hourly rate of gas flow (measured in KWH) for the Daily Metered (DM) portion of the Supply Point. CONTEXT: The new hourly rate of gas flow deemed to be required by the Customer in the future. A code which uniquely identifies a Meter Reading Agency. It is allocated when the agency it is deemed to be acceptable to Transco. CONTEXT: The Meter Reading Agency that the System User wishes to use in the future to read the meters on all the Non Daily Metered (NDM) Meter Points in the Supply Point. MRF_TYPE_CODE TRANSCO_NOMINATION_REFER ENCE RECORDED_DATE RECORDED_TIME O T 1 0 O N 9 0 M D 8 0 M M 6 0 A code identifying a valid meter reading frequency. CONTEXT: The frequency that the System User wishes to read all the meters on Non Daily Metered (NDM) Meter Points in the Supply Point. VALUES: D - Daily, M - Monthly, 6 - Six-monthly, A - Annually. A reference number which uniquely identifies the NOMINATION. CONTEXT: Populated when the request has been referred or rejected after referral only. Not populated if rejected on initial validation. The date on which the original request was recorded on TransCo's System. The time at which the original request was recorded on TransCo's System. 1097
19 A code identifying the type of request that this record represents. VALUE : S23 OUTCOME_CODE Details whether the request has been accepted or rejected by Transco VALUES : AC - Accepted, RJ - M T 2 0 Rejected TRANSCO_NOMINATION_REFER ENCE NOMINATION_SHIPPER_REF METER_POINT_REFERENCE RECORDED_DATE RECORDED_TIME M N 9 0 O T 30 0 M N 10 0 M D 8 0 M M 6 0 A reference number which uniquely identifies the NOMINATION. A reference supplied by the System User when making a Nomination. It may be used by the System User to identify the Nomination and any subsequent Confirmation made for that Nomination. An unique identifier for the point at which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Meter Point References will only be created for new services or when a service is relayed to a different position.context: A Meter Point which is part of the Nomination reference provided. Used as a cross-check to ensure the correct Nomination has been selected. The date on which the original request was recorded on TransCo's System. The time at which the original request was recorded on TransCo's System. 24
20 A code identifyng the type of information that this record represents: Z99 The number of detail records contained within the file. This should not include the Standard Header 9A00) M N 10 0 and Standard Trailer (Z99) but should include any file specific Headers and Trailers specified for this file RECORD_COUNT type,. 13
Project Nexus Workgroup Meter Read Validation. 10 th February 2015
Project Nexus Workgroup Meter Read Validation 10 th February 2015 1 Background 2 The meter read validation principles were developed under The Settlement BRD and formed part of Modification 0432. Concerns
More informationFacilities Operations Meter Reading Guide Version 1.0 October 27, 2017
I. PURPOSE and SCOPE The purpose of this Meter Reading Guide is to ensure the accuracy of in-house meter reading and monthly billing processes. Accurate data is also used to track overall campus energy
More informationdomovea energy tebis
domovea energy tebis TABLE OF CONTENTS TABLE OF CONTENTS Page 1. INTRODUCTION... 2 1.1 PURPOSE OF THE DOCUMENT... 2 2. THE ARCHITECTURE OF ELECTRICITY MEASUREMENT... 3 2.1 OBJECTS USED FOR MEASUREMENT...
More informationE.ON MSE Fixed 1 Year Collective Switch Terms and Conditions
Terms and Conditions Definitions Words shown in bold in these terms and conditions have the meanings shown below. Contract means these terms and conditions together with Your Tariff Details or, if you
More informationJL French, Inc. Shipping Schedule (X ) iconnect, Inc. Version 1.2
JL French, Inc. Shipping Schedule (X12 004010 862) Version 1.2 iconnect, Inc. Revision History Revision Date 1.0 1.1 1.2 2/18/2008 10/21/2008 03/20/2009 Description Created BSS02 segment mapping as 05
More informationDemand Side Response Methodology (DSR) for Use after a Gas Deficit Warning (GDW) Background. Draft Business Rules
Demand Side Response Methodology (DSR) for Use after a Gas Deficit Warning (GDW) Draft Business Rules Version 0.1 Following the broad consensus of Workgroup 0504 meeting 3 (WG3), held on the 10 September
More informationSerial Numbering Of Smart Type Electricity Meters From January 2013
Technical Recommendation M2 Version 1.3 Serial Numbering Of Smart Type Electricity Meters From January 2013 Version Status Date of Issue Reason for change Number 1.0 Superseded September 2012 Issued 1.1
More informationCHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS
CHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS Table of Contents 1. OVERVIEW... 3 1.1. BACKGROUND... 3 1.2. PHASE 1... 3 1.3. PHASE 2... 3 1.3.1. Corporate Actions
More informationUNCC AUG Sub-Committee Friday 11 January 2019 at Radcliffe House, Blenheim Court, Warwick Road, Solihull B91 2AA
UNCC AUG Sub-Committee Friday 11 January 2019 at Radcliffe House, Blenheim Court, Warwick Road, Solihull B91 2AA Attendees Chris Shanley (Chair) (CS) Joint Office Mike Berrisford (Secretary) (MB) Joint
More informationOverview of Metering Assurance in the Capacity Market
Public Overview of Metering Assurance in the Capacity Market 21 February 2017 Iain Nicoll EMRS Tushar Singh EMR Delivery Body Joy Nnamani EMRS Matthew Johnson ESC What we will cover today? Topic Roles
More informationManual API Meetdata.nl
Version log Manual API Meetdata.nl API version 1 Version 1.0 Date 30-8-2018 Version log Date Comment 1.0 30-8-2018 Manual for the new API of Meetdata.nl. Page 2 of 15 Contents 1 Information for API users
More informationPROJECT BRIEF PROJECT NEXUS. Development of Requirements FINAL DRAFT V1.0. Project Nexus Development of Requirements Project Brief.
PROJECT NEXUS Development of Requirements PROJECT BRIEF FINAL DRAFT V1.0 22nd October 2009 Copyright xoserve Limited 2009 1 Final Draft V1.0 About this document xoserve is planning a major systems investment
More informationCHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS
CHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS Table of Contents 1. OVERVIEW... 3 1.1. BACKGROUND... 3 1.2. PHASE 1... 3 1.3. PHASE 2... 3 1.3.1. Corporate Actions
More informationEvaluation of Algorithm Performance /06 Gas Year Scaling Factor and Weather Correction Factor
Evaluation of Algorithm Performance - 2005/06 Gas Year Scaling Factor and Weather Correction Factor The annual gas year algorithm performance evaluation normally considers three sources of information
More informationE.ON Saver Plus Fixed 1 Year Terms and Conditions
Terms and Conditions Definitions Words shown in bold in these terms and conditions have the meanings shown below. Confirmation Letter means the letter we send you to confirm details of your Deemed Contract
More informationJuly Contents. Gas Demand Side Response Methodology Final Version. UK Gas Transmission
July 2016 Contents ef Gas Demand Side Response Methodology Final Version UK Gas Transmission Background This document sets out the Gas Demand Side Response (DSR) Methodology which is required to be established
More informationTransmission Availability Data System (TADS) DATA REPORTING INSTRUCTION MANUAL
Transmission Availability Data System (TADS) DATA REPORTING INSTRUCTION MANUAL Version History Version History Version Date October 17, 2007 November 20, 2007 New Major Changes P. 4. Table 1.5, third row
More informationIBM C IBM WebSphere Business Modeler Advanced Edition V7.0, Business Analysis and Design.
IBM C9550-606 IBM WebSphere Business Modeler Advanced Edition V7.0, Business Analysis and Design http://killexams.com/exam-detail/c9550-606 A. Open the "Widget" business item and remove the Parent template
More informationswb customer service SWB MADE EASY
swb customer service SWB MADE EASY What is swb? swb is the energy provider for Bremen and Bremerhaven. This information sheet gives you an overview of everything you need to know to allow us to supply
More informationSTATE LOTTERIES ACT 1966 LOTTERIES (SET FOR LIFE) RULES
STATE LOTTERIES ACT 1966 LOTTERIES (SET FOR LIFE) RULES This consolidation is of effect as at 27 October 2016. It is provided for convenient reference only and regard should be had to the full text of
More informationThe Consolidated Edison Company of New York 867 Monthly Usage Supplemental Information
1. Email Correspondence to Discontinue 2. BPT Beginning Segment for Product Transfer and Resale 3. DTM Date / Time Reference (Next Meter Read Date) Once an E/M is on EDI for a particular transaction, Con
More informationCHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS
CHESS Release Business and Technical Overview Client Segregation Enhancements to CHESS Table of Contents 1. OVERVIEW... 43 1.1. BACKGROUND... 43 1.2. PHASE 1... 43 1.3. PHASE 2... 43 1.3.1. Corporate Actions
More informationMessage Implementation Guideline CCUSA_003050_830. Based on. 830 Planning Schedule with Release Capability X
Message Guideline CCUSA_003050_830 Based on 830 Planning Schedule with Release Capability X12 003050 Version 1.2: September Change History Date Chapter Description 1.0 12-Apr-2018 All Document created
More informationEngineering Recommendation M30 Issue Standard Electricity Network Operator Electricity Smart Meter Configurations
PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation M30 Standard Electricity Network Operator Electricity Smart Meter s www.energynetworks.org PUBLISHING AND
More informationThe 2015 CQ World-Wide WPX Contest
The 2015 CQ World-Wide WPX Contest SSB: March 28-29, 2015 Starts: 0000 UTC Saturday Ends: 2359 UTC Sunday I. Objective: For amateurs world wide to contact as many amateurs and prefixes as possible during
More informationStandard MOD Area Interchange Methodology
A. Introduction 1. Title: Area Interchange Methodology 2. Number: MOD-028-2 3. Purpose: To increase consistency and reliability in the development and documentation of Transfer Capability calculations
More informationPRIVATE LINE LOCAL CHANNEL SERVICES TARIFF
Reissued PAGE NO. 1 CANCELS PAGE NO. 1 TARIFF RULE TABLE OF CONTENTS REVISION PAGE Table of Contents Reissued 1 I. General Reissued 2 Provisions of Service Reissued 2 Responsibility of the Customer Reissued
More informationStandard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC
A. Introduction 1. Title: Generator Frequency and Voltage Protective Relay Settings 2. Number: PRC-024-2 3. Purpose: Ensure Generator Owners set their generator protective relays such that generating units
More informationDocument C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting
Document C-29 Procedures for System Modeling: January 5 th, 2016 TFSS Revisions Clean Open Process Posting Prepared by the SS-37 Working Group on Base Case Development for the Task Force on System Studies.
More informationTYPE APPROVAL PROCEDURE
Approval Amendment Record Approval Date Version Description 15/06/2012 1 Initial issue under MTM. Replaces Connex documents cml- 8.13-PR-002 & cml-8.21-po-168 30/11/2012 2 Document revised and updated
More informationBelgium % Germany % Greece % Spain % France % Ireland % Italy % Cyprus % Luxembourg 0.
ISSUE OF BANKNOTES IN THE EUROSYSTEM Euro banknotes 1 represent a legal tender in all the participating member states; freely circulating within the euro area; they are reissued by members of the Eurosystem
More informationP292 Amending Supplier & Meter Operator Agent responsibilities for smart Meter Technical Details
Stage 01: What stage is this document in the process? Amending Supplier & Meter Operator Agent responsibilities for smart Meter Technical Details This Modification Proposal seeks to enable changes to Supplier
More informationMULTIPLE ORGANISATION ( MULTI ORG )
MULTIPLE ORGANISATION ( MULTI ORG ) Oracle Financials R12 www.erpstuff.com INDEX MULTI ORGANISATION Introduction Benefits Multi Org Structure in Release 11 and Release 12 Release 11 Versus Release 12 Important
More informationSTATE LOTTERIES ACT 1966 LOTTERIES (MONDAY AND WEDNESDAY X LOTTO) RULES
STATE LOTTERIES ACT 1966 LOTTERIES (MONDAY AND WEDNESDAY X LOTTO) RULES This consolidation includes amendments as at 27 October 2016. It is provided for convenient reference only and regard should be had
More informationApplication for electricity connections Housing development for up to four dwellings
Electricity Thank you for considering Western Power Distribution for your electricity connections. We have put together these notes to help you fill out your and to ensure we receive all the correct information
More informationModular Metering System ModbusTCP Communications Manual
Modular Metering System Manual Revision 7 Published October 2016 Northern Design Metering Solutions Modular Metering System ModbusTCP 1 Description The multicube modular electricity metering system simultaneously
More informationReport to Frack Free Frodsham & Helsby. Survey Analysis and Report of Residents Attitudes Towards Shale Gas Fracking in Helsby Parish Council Area
Report to Frack Free Frodsham & Helsby Survey Analysis and Report of Residents Attitudes Towards Shale Gas Fracking in Helsby Parish Council Area Author: John Murray BSc (hons) FBCS FSS CITP CEng Date:
More informationMinutes CuS project meeting
Minutes CuS meeting, June 1 st and 2 nd, 2016 June 14 th, 2016 European forum for energy Business Information exchange CuS, Structuring of the energy market, phase V Minutes CuS project meeting Date: Wednesday
More informationMEMORANDUM. Figure 1: Current Drive-By Meter Reading System. Handheld Collector Communicates with Radio Transmitter to Collect Data
MEMORANDUM TO: ROB HAYES, DPS DIRECTOR/CITY ENGINEER FROM: TIM KUHNS, WATER AND SEWER SENIOR ENGINEER SUBJECT: ADVANCED METERING INFRASTRUCTURE (AMI) SYSTEM DATE: APRIL 24, 2015 Advanced metering infrastructure
More informationThe Namibian Grid Code
The Namibian Grid Code The Metering Code 1 of 6 Code Documents Final May 2005 Enquiries: Electricity Control Board, +264-61-374 300, Namibia Table of Contents 1. Introduction... 3 2. Application of the
More informationREPORT ON THE EUROSTAT 2017 USER SATISFACTION SURVEY
EUROPEAN COMMISSION EUROSTAT Directorate A: Cooperation in the European Statistical System; international cooperation; resources Unit A2: Strategy and Planning REPORT ON THE EUROSTAT 2017 USER SATISFACTION
More informationWIPO WORLD ORGANIZATION
WIPO WORLD INTELLECTUAL ORGANIZATION PROPERTY C.N3159 The International Bureau of the World Intellectual Property Organization (WIPO) presents its compliments and has the honor to refer to the attached
More informationJEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia
BULLETIN NO. 6 TO THE PLANS AND SPECIFICATIONS FOR JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia EwingCole Architects.Engineers.Interior Designers.Planners
More informationState College Area School District
State College Area School District The following is a guideline for project design submittals to the Facility Committee of the State College Area School District. During the design process the committee
More informationStandard Development Timeline
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the NERC Board of Trustees (Board).
More informationDOLLAR GENERAL CORPORATION Electronic Data Interchange. Motor Carrier Shipment Information 204 Carrier Mapping Guidelines. ANSI X12 Version 4010
DOLLAR GENERAL CORPORATION Electronic Data Interchange Motor Carrier Shipment Information 204 Carrier Mapping Guidelines ANSI X12 Version 4010 Implementation Guideline 204 Version: 1-04/06/04 Page 1 Implementation
More informationFinal technical report on Improvement of the use of administrative sources (ESS.VIP ADMIN WP6 Pilot studies and applications)
Ref. Ares(2017)888280-17/02/2017 Page REPORT 1 (12) 2016-11-03 Claus-Göran Hjelm Final technical report on Improvement of the use of administrative sources (ESS.VIP ADMIN WP6 Pilot studies and applications)
More informationSULTANATE OF OMAN METERING AND DATA EXCHANGE CODE
1.0 GENERAL SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE STANDARD: OES-22F THREE PHASE KILOWATT-HOUR DIGITAL METERS, CURRENT TRANSFORMER OPERATED, CONNECTED FOR SERVICE CONNECTIONS Electronic three
More informationWIRELESS RF TRANSCEIVER FOR ENERGY METER READING SYSTEM
International Journal of Advanced Research in Engineering ISSN: 2394-2819 Technology & Sciences Email:editor@ijarets.org May-2016 Volume 3, Issue-5 www.ijarets.org WIRELESS RF TRANSCEIVER FOR ENERGY METER
More informationIntroduction: Notes: Heading: Functional Group ID=PO
850 Purchase Order Functional Group ID=PO Introduction: This Draft Standard for Trial Use contains the format and establishes the data contents of the Purchase Order Transaction Set (850) for use within
More informationFinal ballot January BOT adoption February 2015
Standard PRC-024-21(X) Generator Frequency and Voltage Protective Relay Settings Standard Development Timeline This section is maintained by the drafting team during the development of the standard and
More informationSECTION SUBMITTAL PROCEDURES
SECTION 01330 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 1 Specification
More informationCode of practice for accurate bills Billing code scenarios
Code of practice for accurate bills Billing code scenarios Version: January 2015 Contents Introduction 3 Switching 4 Meter reading 5 Energy bills and statements 6 Payments and refunds 8 Back billing 9
More informationKomatsu America ASC X Payment Order / Remittance Advice. Implementation Guideline. January 10, Table of Contents.
Komatsu America 400 ASC X2.820 Implementation Guideline January 0, 2002 Table of Contents Page Introduction General Rules Segments 2 Fields 6 Example 2 ASC X2 VERSION 004 RELEASE 00 PAYMENT ORDER /REMITTANCE
More informationTechnical Data Standards Development & Implementation
Technical Data Standards Development & Implementation Technical Data, Technical Global Upstream Business All rights reserved. No part of this document may be reproduced, stored in a retrieval system or
More informationSubmission to the Ministry of Economic Development. on MHz Band Replanning Options
Submission to the Ministry of Economic Development on 806-960 MHz Band Replanning Options 30 July 2009 Background Metrix, a business unit of Mighty River Power Ltd (MRP), is presently installing Advanced
More informationA. Action Submittals: Written and graphic information that requires Engineer's responsive action.
SECTION 01330 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 1 Specification
More informationProcedure for Obtaining data by Implementing Agency for Determination of PoC Transmission Charges and Losses
Procedure for Obtaining data by Implementing Agency for Determination of PoC Transmission Charges and Losses In compliance of Central Electricity Regulatory Commission (Sharing of inter-state Transmission
More informationPatient Choice and Resource Allocation Policy. NHS South Warwickshire Clinical Commissioning Group (the CCG)
Patient Choice and Resource Allocation Policy (the CCG) Accountable Director: Alison Walshe Director of Quality and Performance Policy Author: Sheila Browning Associate Director Continuing Healthcare Approved
More informationELECTRICITY NETWORKS ACCESS CODE SERVICE STANDARD PERFORMANCE REPORT for the year ended 30 June 2016
ELECTRICITY NETWORKS ACCESS CODE 2004 SERVICE STANDARD PERFORMANCE REPORT for the year ended 30 June 2016 SEPTEMBER 2016 EDM 40542141 Page 1 of 43 Contents 1 Executive Summary... 4 2 Background... 6 3
More informationGENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw
GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw ELECTRIC UTILITY CONTACT INFORMATION Consumers Energy
More informationEverBlu. Wireless fixed data collection system
Solution EverBlu Wireless fixed data collection system > Automatic daily meter reads > Graphical data analysis > Reliable self-healing wireless mesh network > Suitable for urban, suburban and rural environments
More informationProduct Manual SE1000. Description The SE1000 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs.
Product Manual SE1 Utility Meter Pulse Transducer Communicating Controls Description The SE1 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs. Features Stand-alone
More informationAnnouncing: 2017 CQ WW DX RTTY Contest September Starts 0000 UTC Saturday Ends 2359 UTC Sunday
Announcing: 2017 CQ WW DX RTTY Contest September 23-24 Starts 0000 UTC Saturday Ends 2359 UTC Sunday I. OBJECTIVE: For amateurs around the world to contact as many other amateurs in as many CQ zones, countries
More informationAmazon Studios. Contest Rules. for the. Best Horror/Thriller Trailer Award for Fourth Week of February 2012
Amazon Studios Contest Rules for the Best Horror/Thriller Trailer Award for Fourth Week of February 2012 NO PURCHASE IS NECESSARY TO ENTER OR WIN. THIS IS NOT A PRIZE DRAW BUT A SKILL-BASED COMPETITION.
More informationInstallation and Operating Instructions
Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2
More informationEuropean Update. 5 th May 2016
European Update Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight line. 5 th May 2016 1. General Update
More informationNahz Anvary, CCIM Senior Vice President LIC #
FOR LEASE 606 and 630 Peña Drive in the Mace Ranch neighborhood in East Davis provide a great opportunity to lease ±1,621 or ±1,963 square feet of flex/tech/office/lab space in Davis. These buildings are
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationCalculating and Using Reporting ACE in a Tie Line Bias Control Program
Calculating and Using Reporting ACE in a Tie Line Bias Control Program Introduction: Tie Line Bias 1 (TLB) control has been used as the preferred control method in North America for 75 years. In the early
More informationABI Framework for the Management of Gone-Away Customers in the Life and Pensions Market
1 Association of British Insurers ABI Framework for the Management of Gone-Away Customers in the Life and Pensions Market ABI Framework for the Management of Gone-Away Customers in the Life and Pensions
More informationSECTION SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 01 33 00 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationIntimate Communications Hub Interface Specification Report to Secretary of State
Intimate Communications Hub Interface Specification Report to Secretary of State DCC V1.0 28/02/14 Page 1 of 14 Executive Summary 1. DCC is required in accordance with the terms of its Licence to produce,
More informationConnection Impact Assessment Application Form
Connection Impact Assessment Application Form This Application Form is for Generators applying for a Connection Impact Assessment (CIA). In certain circumstances, London Hydro may require additional information
More informationDNVGL-CP-0338 Edition October 2015
CLASS PROGRAMME DNVGL-CP-0338 Edition October 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD DNV GL class
More informationClick to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance
Click to edit Master title style Click to edit Master title style Northern Powergrid Asset Recording Guidance Rules for ICP & IDNO Version 1.0 April 2017 Introduction Accurate records for all assets are
More information855 Purchase Order Acknowledgment
855 Purchase Order Acknowledgment Functional Group ID=PR Introduction: This Draft Standard for Trial Use contains the format and establishes the data contents of the Purchase Order Acknowledgment Transaction
More information< The Family Demographics table contains the family demographic data, including home address and phone number
The Church Executive Family Demographics Introduction Index Introduction... 1 Definitions... 2 Drop-down Lists... 3 User-defined fields... 4 Procedure... 5 Fields... 6 Family Members... 9 The Family Demographics
More informationStalker Speed Sensor II Traffic Statistics Sensor Manual rev A
Stalker Speed Sensor II Traffic Statistics Sensor Manual 011-0132-00 rev A Applied Concepts, Inc. 2609 Technology Drive Plano, Texas 75074 972-398-3780 ii Applied Concepts TRAFFIC STATISTICS SPEED SENSOR
More informationTerms of Business for ICICI Bank Investment Services (effective from October, 2013)
Terms of Business for ICICI Bank Investment Services (effective from October, 2013) Section Page No. How does this investment service work? 2 What is this document for? 2 Definitions 3-4 A. Terms and Conditions
More informationEmbedded Generation Connection Application Form
Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed
More informationPower Proportional Distribution (PPD)
AN-PPD-11-18 Power Proportional Distribution (PPD) Application Note Table of Contents 1. Description... 3 2. Application and Design... 3 2.1 PPD Application with an intelligent Touch Controller (itc)...
More informationFCC MOVING ON COMMERCIAL USE OF 3.5 GHz BAND; IMMINENT OPPORTUNITIES FOR RF EQUIPMENT SUPPLIERS AND SERVICE PROVIDERS
FCC MOVING ON COMMERCIAL USE OF 3.5 GHz BAND; IMMINENT OPPORTUNITIES FOR RF EQUIPMENT SUPPLIERS AND SERVICE PROVIDERS By Ronald E. Quirk, Jr., Esq. The Federal Communications Commission ( FCC or Commission
More informationTHE 51st ANNUAL AWGIE AWARDS CATEGORIES AND CONDITIONS OF ENTRY
CATEGORIES FEATURE FILM THE 51st ANNUAL AWGIE AWARDS CATEGORIES Feature Film Original Feature Film Adaptation SHORT FILM AND CONDITIONS OF ENTRY Short Film Changed Category Please see new Conditions of
More informationADDENDUM D COMERICA WEB INVOICING TERMS AND CONDITIONS
Effective 08/15/2013 ADDENDUM D COMERICA WEB INVOICING TERMS AND CONDITIONS This Addendum D is incorporated by this reference into the Comerica Web Banking Terms and Conditions ( Terms ). Capitalized terms
More informationRFID ACCESS CONTROL. SRðAN LALE FACULTY OF ELECTRICAL ENGINEERING EASTERN SARAJEVO
RFID ACCESS CONTROL SRðAN LALE FACULTY OF ELECTRICAL ENGINEERING EASTERN SARAJEVO 1 INTRODUCTION RFID (RADIO - FREQUENCY IDENTIFICATION) systems use RF signals for identification of people, animals and
More informationLogical Trunked. Radio (LTR) Theory of Operation
Logical Trunked Radio (LTR) Theory of Operation An Introduction to the Logical Trunking Radio Protocol on the Motorola Commercial and Professional Series Radios Contents 1. Introduction...2 1.1 Logical
More informationField Tickets Frequently Asked Questions
When should I contact the Husky procurement technician (purchase order owner)? If the field ticket has not been actioned for a long time and you are waiting to invoice. If the purchase order (PO) from
More informationElectricity Tariffs for Voltage-dependent Loads
Electricity Tariffs for Voltage-dependent Loads Authors: Prof C. S. Indulkar and Dr K. Ramalingam Presenter : Dr K. Ramalingam Abstract These days the regulators specify that the tariff report should include:
More informationOracle Utilities SGG V2.0.0 and MDM V2.0.1 Integrations. Utility Reference Model a SGG-MDM. Upload Device Measurements (L+G)
Oracle Utilities SGG V2.0.0 and MDM V2.0.1 Integrations Utility Reference Model 4.2.1.1a SGG-MDM. Upload Device Measurements (L+G) May 2013 Oracle Utilities SGG V2.0.0 to MDM V2.0.1 Integration Utility
More information867 Product Transfer and Resale Report
867 Product Transfer and Resale Report Introduction: NAESB WGQ Standard No. 2.4.6 - Measured Volume Audit Statement Heading: Functional Group ID=PT Pos. Seg. Req. Loop Notes and No. ID Name Des. Max.Use
More informationH Y D R O. ICO: August 24, 2017 Written: June 16, 2017
H Y D R O ICO: August 24, 2017 Written: June 16, 2017 Hydro Coin is the working name for the conceptualization of water as a currency and furthermore the inception of water as a tradable commodity. Hydro
More informationSOP for GeoMGNREGA Phase II
SOP for GeoMGNREGA Phase II ANNEXURE-I 1. Introduction: Creation of durable assets and strengthening of rural livelihood is an important objective under the Mahatma Gandhi NREGA. On an average, 30 Lakh
More informationGreenlining and Bluelining of Ergon Energy Substation Drawings
Greenlining and Bluelining of Ergon Energy Table of Contents Purpose and Scope... 1 Responsibilities... 1 Definitions, Abbreviations and Acronyms... 1 References... 1 General... 1 Requirements... 3 Testing
More informationDepartment for Education and Child Development School Enrolment Census Data Quality Statement
Department for Education and Child Development School Enrolment Census Data Quality Statement PUBLISHED OCTOBER 2011 VERSION 1.00 -REVIEWED ANNUALLY- Due for Review: October 2012 www.santdatalink.org.au
More informationConnection Impact Assessment Application
Connection Impact Assessment Application This form is for generators applying for Connection Impact Assessment (CIA) and for generators with a project size >10 kw. Please return the completed form by email,
More informationREGIONAL DISTRICT OF NORTH OKANAGAN Metering Program Frequently Asked Questions & Answers
WATER METER IMPROVEMENT PROGRAM The Regional District of North Okanagan (RDNO) - Greater Vernon Water (GVW) is implementing a Water Meter Improvement Program. Automatic Meter Reading (AMR) technology is
More informationTechnician TRAINING WORKBOOK
Technician TRAINING WORKBOOK XSELLERATOR Service Terminology Definitions... 2 Clocking Into-Out of XSELLERATOR Technician... 4 Logging On and Off a Work Order... 4 Recording Straight Time... 6 Requesting
More informationIdentification number : Jean-Louis MARTINAUD. 1, Place Samuel de Champlain PARIS LA DEFENSE Cedex. Address
Identification number : 90947457424-20 GDF SUEZ answers to ACER consultation paper on «PC-07- draft framework guidelines on interoperability rules and data exchange for the European gas transmission networks»
More informationDATE: 17/08/2006 Issue No 2 e-plate Operation Overview
Page 1 of 7 Fundamentals Introduction e-pate technology is the next generation of long range RFID (Radio Frequency IDentification). The objective is wireless and automated data collection of vehicles and
More information