Specification for Lightning Sensor

Size: px
Start display at page:

Download "Specification for Lightning Sensor"

Transcription

1 Specification for Lightning Sensor Patent Pending November

2 Content: 1. General description 2. Functional description 3. Electrical connections. 4. Electrical specifications. 5. Mechanical specifications. 6. Norms and standards. 7. Maintenance.

3 1. General description. At lightning strikes directly into the tower, where the lightning sensor is mounted, an immediate relay signal activates, telling that a strike has just taken place. At direct strikes in the neighbourhood of the tower, no indication will take place. Additionally no indication will happen at disturbances in the power supply circuit to the sensor. The lightning sensor detects as well weak as very strong strikes. By failures in the power supply (power-failure), the lightning sensor will continue to register lightning strikes and keep that information until full power supply is re-established and a relay signal is send out. The power supply is supervised electronically and by errors a relay signal is send out. Antenna Converterbox Antenna Optical fibre Controlbox + - Power Power failure Reset Lightning

4 2. Functional description Building blocks: The lightning strike will be detected by antennas that are smaller than a A4 piece of paper. The signals from the antennas are transformed from an electrical signal to an optical signal, which is transferred via an optical fibre to a control box, which may be placed in the turbine control rack. A complete galvanic isolation is by then obtained between the antenna and the control box. The relay output from the control box tells that there has been a lightning strike and it tells just immediately after the strike. The control box shows the lightning signal until the turbine control has send an acknowledge by sending a reset signal. Function: After signalling through the optical fibre a zero potential contact is switched on as an indication of a lightning strike. It is possible by internal jumpers to bring the output normal open or normal closed. At the normal closed setting a signal will also occur by cable failures. A drop of power supply will signal on the Power relay. This relay can also be set as normal open or normal closed. The Power Failure Relay signals at power drop out from the external supply. It also signals in case of failure from the internal lithium battery. The lightning sensor detects strikes even without the presence of external power supply. The battery lifetime is approx.1 month. At the reestablishment of the external power supply, the lightning relay will indicate strike, if there was a strike before the power was re-established. Then detection will also take place if the lightning sensor is not supplied by external power, as an example if the turbine is in a repair period. The lightning relay will only be reset after an active reset signal coming from outside. This reset signal must be of 5-10 sec. Of endurance. This lowers the risk of a reset just by electrical noise. The reset signal can be either an AC or DC signal in region 5-24V. The reset circuit is overvoltage protected and optical isolated from the rest of the control box circuit. On the control box a red LED shows the lightning detection. A green LED indicates external power supply. A red LED shows output from power failure circuit (only active if external supply is present) The external supply is protected against even high noise levels and other disturbances from outside.

5 3. Electrical connections. The control box cable is connected to the control box by the accommodating connector (Type C 091 D, IEC130-9, IP67): Connector seen from soldering end. A cable with screen must be used. Preferred external diameter is 6-7 mm. The connector has these connections: Pin 1 and 2: Power-failure relay Pin 3 and 6: Reset off lightning relay (pin 3 = negative at DC) Pin 4 and 5: Lightning relay 230V supply The 230V supply is connected via a IEC connector. The supply must have maximum 10Amp fuse.

6 4. Electrical specifications. Detection level: Lightning current from approx. 500A to approx A may be detected (8/20-8/350uSec). The trigger level is adjustable in the antenna box. The trigger level is adjustable to specific levels: 1kA, 2kA, 4kA or 8kA, resolution +/- 10% on table values. These values are depending on the distance between the antennas. The values are finally calculated in a table. Adjustment of the trigger level is done by change of connections inside the antenna box. The trigger current is filtered as a first order band-pass filter, having a specific characteristic. please ask Jomitek for more details. For a tower having a radius of 2,2 meters, the sensitivity is: Lightning Sensor Sensitivity 12,0 11,0 10,0 9,0 8,0 ka 7,0 6,0 5,0 4,0 3,0 2,0 1,0 0,0 0, kA adjust. 2kA adjust. 4kA adjust. 8kA adjust. Rise time, usec

7 Relay output: Relay outputs are with gold plated contacts. Max current Max voltage at contacts: Max voltage according to VDE 0110b (2/79) isolation group A Contact resistance Isolation at 500 V Isolation voltage according to Bellcore TR-NWT (2/10uS) 2A 220V DC /250V AC 150V DC / 125V AC <50mohm / 10mA /20mV 10 9 ohm 2000V Reset signal: Reset signal must be applied for at least 10 sec. AC or DC signal in the range 5-24V. Typical input current 1-4mA At DC input, pin 3 must be negative. External power supply: 230V edition: Connector IEC-320 type B, 3pin, 230V and earth (common connectors). Continuous voltage must be between 196V and 265V V AC editions on request. Power consumption less than 3W. Battery supply: The battery has an expected lifetime of 10 years. The battery lifetime will be shortened dramatically if there is often periods (days) without external power supply. The battery may be changed with a similar 3,7V Lithium battery, when the supervision circuit reports battery failure. The battery supervision circuit will not report failure if the battery is completely disconnected or removed. The battery is not connected at the delivery of the sensor. Temperature range: Antenna: No limits Antenna box and control box: from -20 to +50 degrees Celsius. Materials: Antenna is made of stainless steel. The antenna box and control box is made of EMC tight aluminium. DIN rail adapters on request. Other types of boxes on request. Enclosure: Antennas fulfil IP67. Cables and boxes fulfil IP55.

8 6 5, 0 m m 8, 3 0 c m 5. Mechanical specification Control box: height approx. 75mm above DIN rail 17,90 cm + - Reset 10 sec. Converter box: height approx. 49 mm, but may be changed. 145,0 mm Antenna: Antenna height and width may be changed without notice. 90 degree edition: Cables: The antenna cable is RG58 coax and may be with or without connector at the antenna end. Connector at converter box end is assembled from factory. Optical cable is a 1mm plastic fiber in a 6mm plastic tube and assembled with optical connectors.

9 6. Norms and standards. The lightning sensor system fulfils all relevant EU-Norms and international standards. The lightning sensor is an advanced electronic equipment. Only qualified and electrical educated personal may install the equipment. In case of need for battery exchange etc. the lightning sensor control box must only be opened by qualified electrical educated personal. Due to possible corrosion the boxes may only be opened in short periods of time. 7. Maintenance. a. Initial installation. As soon as the power supply in the turbine is stable, the internal battery may be connected. The battery supervision circuit does not report error when the battery is completely disconnected. The battery is not connected at delivery of the box. b. Maintenance planning It is a good idea once per year to test the lightning sensor. This test may be done by applying a lightning field on each antenna. The battery is designed for a 10 years lifetime at seldom and short drop out of the mains voltage. The battery life time is approx days at missing mains supply. The battery must be changed minimum every 10 years.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

USB-TC Instructions. Description

USB-TC Instructions. Description Description USB-TC Instructions The USB Temperature Controller (USB-TC) is a heating device that attaches to the bottom of an Ocean Optics USB Series spectrometer. This add-on option heats the spectrometer

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

PRO Professional Radio Control Series Applications

PRO Professional Radio Control Series Applications 204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting

More information

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany 522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524

More information

Datasheet - PROTECT-IE-02

Datasheet - PROTECT-IE-02 Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

RF Remote Control Unit SEAV

RF Remote Control Unit SEAV RF Remote Control Unit SEAV for LINAK TECH-systems Installation instructions Foreword Dear producer, Thank you for choosing an actuator system from LINAK. LINAK systems consist of high-tech products based

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Acceleration sensors With relay output for limit monitoring Analog / CANopen Features Acceleration sensor / analog / CANopen Up to two relay outputs for limit monitoring 3 axes detection, MEMS based Measuring range ±2 g Connection: connector M12, 12-pin Offshore capability (plastic

More information

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8 PRO-BLADE8 Ready to Use Remote Control 8 Channel Systems Range: PROFLY Up to 100 metres PROBLADE Up to 500 metres Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting Control General

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection... instrumentación para fluidos CI- pulse / ma Converter Instruction Manual TABLE OF CONTENTS PRINCIPLE OF OPERATION.... Limitations.... INSTALLATION.... Mains connection........ Input connection........

More information

IsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission

IsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission Standard-Signal Isolation Amplifiers For transmission and conversion of impressed measurement signals. The components typically required for modulation amplifiers and resistance networks are unnecessary.

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

RG142-TNMNM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR. Regulatory Compliance/Certifications

RG142-TNMNM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR. Regulatory Compliance/Certifications RG142-TNMNM-3M Product Classification Product Series Product Type RG142 CNT Jumper with interface types and, 3 m RG142 Braided cable assembly General Specifications Body Style, Connector A Body Style,

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Transmitter First Class Advanced Classified according to IEC ( ) THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021519/01/09 Wind Transmitter First Class Advanced Classified according to IEC 61400-12-1 (2005-12)

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

Loop-Powered Isolators for Standard Signals

Loop-Powered Isolators for Standard Signals Loop-Powered Isolators for Standard Signals For isolation of 0(4) 20 ma standard signals without power supply in 19" technology The Housing The integration of several modules on one Eurocard results in

More information

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and

More information

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values k For measured temperatures from -30... +260 C or -200... +600 C k For mobile or stationary temperature measurement

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Totalizing Counters mini-i

Totalizing Counters mini-i mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid

More information

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC Catalogue 1SFC 266006-en, Edition 3 November 2003 Supersedes Catalogue 1SFC 266006-en, Edition 2 November 2000 Arc Guard System TVOC System units The two units of the are used as below: Approvals 1. with

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Arc Sensor User Manual

Arc Sensor User Manual MN026008EN Arc Sensor User Manual EAFR-01 EAFR-06 EAFR-08 EAFR-07 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document

More information

200, 201 Series Radio Telemetry Transmitters

200, 201 Series Radio Telemetry Transmitters 200 DIN Rail Transmitter Encoder Up to 8 Input Channels Volt Free contact Inputs via Screw Terminals 12 / 24Vdc Supply Range; 433MHz Up to 200 Metres 433MHz NB Up to 1,000 Metres 458MHz Up to 6,000 Metres

More information

Wind Turbine Analysis System - Type 3652 MKII & MKIII

Wind Turbine Analysis System - Type 3652 MKII & MKIII Wind Turbine Analysis System - Type 3652 MKII & MKIII The Wind Turbine Analysis System Type 3652 (WTAS 3652) is designed for remotely acquiring scalar vibration data, process parameters and time series

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

Conductivity Transmitter N-LF V AC

Conductivity Transmitter N-LF V AC OPERATING INSTRUCTIONS Conductivity Transmitter N-LF2000 230V AC These operating instructions apply to the following device: Article Measuring range Order number N-LF2000, Conductivity measuring device

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features: LVDT Inductive Position Transducer - Hydraulic Series SM-HYD-F18 Hydraulic-Series Key-Features: Content: - M18x1,5 mm integral thread - Operating pressure 150 bar - Ranges 2...200 mm - Linearity up to

More information

5 years! Modular Housings. VariTrans P Warranty

5 years! Modular Housings. VariTrans P Warranty Modular Housings VariTrans P 27000 The Multimeter among the isolators. With 480 switchable calibrated ranges and broad-range power supply. The Task A wide range of measuring signals need to be galvanically

More information

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on

More information

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm Technical data: Measurement range [mm] 0 25 0 50 00 80 0 100 0 150 0 200 0 300 0 600 Linearity 0,30% (0,20% Optional), 1,50% for a range

More information

Radar Scanner CRAT20-11/11 - normal beam angle - long range

Radar Scanner CRAT20-11/11 - normal beam angle - long range Radar Scanner CRAT2-11/11 - normal beam angle - long range PETER - PAUL TITZE IDEEN IN SENSORIK 1 Preliminary data sheet Description 11 35 65 42 1 The radar scanner is a FMCW-Radar and works in the frequency

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

M-0418 REV:0

M-0418 REV:0 1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that

More information

6. Internal lightning protection

6. Internal lightning protection 6. Internal lightning protection 6.1 Equipotential bonding for metal installations Equipotential bonding according to IEC 60364-4- 41 and IEC 60364-5-54 Equipotential bonding is required for all newly

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals. Universal Isolation Amplifiers IsoAmp 11000/12000 Universal isolation amplifiers for ±20 mv to or input signals. The Problems When conventional unsymmetrical isolation amplifiers are used, measurement

More information

AC AC AC

AC AC AC AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry

More information

Industrial Power Supplies

Industrial Power Supplies Industrial Power Supplies Enduring High Quality Products 24 Volt Industrial Din Rail 120W to 480W Description: With built-in PFC 85% - 90% efficiency 60% power boost ability 23.5V to 29V adjustable output

More information

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits SEL-8 Phase Comparison ed Circuit Indicator (PC FCI) SEL-8 SEL-8 SEL-8 SEL-8 SEL-8 SEL-8 Communicates to line crews using the Features and Benefits Locates ed Cable Sections Quickly Locate cable failures

More information

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS Lightning Strikes Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS ARRL CT State Technical Coordinator The Power of Lightning What is a Ground? Design

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Fibre-optic units SOE4

Fibre-optic units SOE4 Product overview Product overview Version Type Type of display Timer function Switching output Analogue output Page/Internet Fibre-optic unit SOE4-FO-L LED PNP NPN SOE4-FO-D LED display 1 2000 ms PNP NPN

More information

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA 87.5 TO 108.0 MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA 1. INTRODUCTION 3 1.1. GENERAL INFORMATION 3 1.2. UNPACKING AND CHECKING 3 1.3. WARRANTY 3 1.4. USER SAFETY RESPONSIBILITY 4 1.5. INSTALLATION

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

WS12EX Position Sensor with Analog output Dust explosion-proof

WS12EX Position Sensor with Analog output Dust explosion-proof Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Instruction Manual. TT1000 Tower Earth Tester. Rev 01

Instruction Manual. TT1000 Tower Earth Tester. Rev 01 Instruction Manual TT1000 Tower Earth Tester Rev 01 Contents 1 Introduction... 3 2 Features... 3 3 Operation... 4 3.1 Test Lead Configuration... 5 3.2 Probe Integrity Test... 6 3.3 Impedance measurement...

More information

Differential charge amplifier

Differential charge amplifier Electronics Differential charge amplifier Type 5181A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure

More information

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module Product overview The AX-ROM135 and the AX-ROM1000 Modules enable an Analogue, Pulse or Floating point signal and convert to either a 0-135Ω or a 1KΩ Proportional Resistive output signal. The output resistance

More information

RADIATED IMMUNITY TEST SYSTEM 6 GHz

RADIATED IMMUNITY TEST SYSTEM 6 GHz Integrated signal generator 80 MHz to 6 GHz Integrated RF switch network Integrated freely configurable pulse modulators ( µs to 00 s) for radar pulse profiles Multiple options.5 TFT color display Safety

More information

Adjustable Digital Process Instrument MDK480

Adjustable Digital Process Instrument MDK480 Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot

More information

Series BDF for Process

Series BDF for Process Series DF for Process LARGE DISPLAYS for Process signals DF-xx-32 for ma signals DF-xx-36 for Vdc signals IDEAL SOLUTION for reading process signals at long distances, with scaled values on display, coming

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication D-LAS Series D-LAS-34-ED-25x2-AC-T (Glass Pane Detection) - Collimated laser beam (

More information

S D 1 Operating Instructions

S D 1 Operating Instructions S D 1 Operating Instructions Volutronic 1. SAFETY 3 2. DESCRIPTION 4 3. CONNECTING THE SD1 5 3.1 Connecting the voltage supply 5 3.2 Connecting SD1 with rectangular output. 5 3.3 Connecting the SD1 with

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000 High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

The I-2532 CAN to Fiber Converter

The I-2532 CAN to Fiber Converter The I-2532 CAN to Fiber Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the

More information

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions WARRANTY ADDENDUM TROUBLESHOOTING INSTALLATION OVERVIEW M2 Antenna Systems, Inc. Model No: S3 Sequencer Operating Instructions PLEASE READ BEFORE USE AND SAVE M2 Antenna Systems, Inc. 4402 N. Selland Ave.

More information

Industry's standard of transparent object detection sensor

Industry's standard of transparent object detection sensor 412 Stainless protector/small type series SR-Q series Industry's standard of transparent object detection sensor Stable detection even at close distances Visible red spot light KR-Q series Narrow view

More information

Non-Spring Return EconoDrive Proportional Actuator

Non-Spring Return EconoDrive Proportional Actuator MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

Wind Transmitter - compact

Wind Transmitter - compact THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021194/02/07 Wind Transmitter - compact 4.3518.03.000 4.3519.03.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

LVDT 提夫自控技术 ( 上海 ) 有限公司. Series SL ø 20 mm. Inductive Position Transducer. ranges mm. linearity up to 0,20 % housing ø 20 mm

LVDT 提夫自控技术 ( 上海 ) 有限公司. Series SL ø 20 mm. Inductive Position Transducer. ranges mm. linearity up to 0,20 % housing ø 20 mm 提夫自控技术 ( 上海 ) 有限公司 LVDT Inductive Position Transducer Series SL ø 20 mm ranges 25...600 mm linearity up to 0,20 % housing ø 20 mm output: AC, 0...10 V, 0...5 V, 4...20 ma, 0...20 ma, ±10 V, ±5 V with external

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS ASSEMBLY AND INSTALLATION INSTRUCTIONS R7000 10, 12, 15, 17, 20, 30, 40 Meters COMMUNICATIONS ANTENNAS 951465 (5/99) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT

More information

PST 100 YPSILON PRE AMPLIFIER MKII. OWNERS MANUAL V2 01/01/2010 All rights reserved

PST 100 YPSILON PRE AMPLIFIER MKII. OWNERS MANUAL V2 01/01/2010 All rights reserved PST 100 YPSILON PRE AMPLIFIER MKII OWNERS MANUAL V2 01/01/2010 All rights reserved INTRODUCTION Thank you for trusting YPSILON ELECTRONICS. We assure you that you have made an excellent purchase. Your

More information

MLV40 Series Miniature Sensors

MLV40 Series Miniature Sensors MLV4 Series Miniature Sensors Diffuse Mode See page 54 Features: Adjustable sensitivity Complementary outputs Sensing Range: 5 mm Outputs: NPN, PNP Thru-Beam Mode See page 57 Rugged metal housing Compact

More information

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications.

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications. ATBTK-MF-4G Bias Tee Kit, AISG Compatible 698-2700 MHz Product Classification Product Type RET bias tee Mechanical Specifications Antenna Interface 7-16 DIN Female BTS Interface 7-16 DIN Male Dimensions

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

Strain Gauge Measuring Amplifier BA 662

Strain Gauge Measuring Amplifier BA 662 Strain Gauge Measuring Amplifier BA 662 Original of the Manual Table of Contents 1. Safety precautions... 2 1.1. Field of application... 2 1.2. Installation... 2 1.3. Maintenance... 2 2. Function... 2

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position 2 optoncdt 2401 Confocal displacement measurement system - Non-contact measurement principle

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

Temperature sensor with integrated transmitter for maritime applications, MBT 5560 Temperature sensor with integrated transmitter for maritime applications, MBT 5560 Technical brochure Features Designed for use in harsh maritme environments where reliable, robust and accurate equipment

More information

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary

More information

The Rosemount 848T Wireless Temperature Transmitter

The Rosemount 848T Wireless Temperature Transmitter Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs

More information

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

SMART TWEEZERS Model ST-1 User s Manual Version 1.0 SMART TWEEZERS Model ST-1 User s Manual Version 1.0 Patent Pending TABLE OF CONTENTS Notice The contents of this document is believed to be accurate, but is not guaranteed by Excelta Corporation. The information

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

Ameritron RCS-10 INTRODUCTION

Ameritron RCS-10 INTRODUCTION Ameritron RCS-10 INTRODUCTION The RCS-10 is a versatile antenna switch designed for 50-ohm systems. It handles high power, and sealed relays offer excellent life and connection reliability. It requires

More information