Sigfox RF & Protocol Test Procedure RSA-SDR-DONGLE for RC3c-UDL-ENC
|
|
- Preston Hampton
- 5 years ago
- Views:
Transcription
1 Version September 14, 2018 Sigfox RF & Protocol Test Procedure RSA-SDR-DONGLE for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This document is the property of Sigfox. It shall not be copied and / or disclosed to third parties, in any form without Sigfox written permission.
2 IMPORTANT NOTICE The device proposed in Sigfox RF & Protocol Tests has to be representative of the ones present in the field. To succeed in your Sigfox RF & Protocol Tests, you need to : Read carefully the Radio_Signal_Analyzer User Guide (available on Build Website: https: // build. sigfox. com ). Have a Sigfox Checklist (available on Build Website: https: // build. sigfox. com ) properly filled in (all information in the checklist will be used all tests long). 1
3 Contents 1 Introduction Scope Acronyms and abbreviations Radio_Signal_Analyzer User guide Verdict Type Checklist Information Sigfox RF & Protocol Tests Test Setup Tests Execution Execute with Test Mode : TX-BPSK a Nominal Voltage Configuration b Minimum Voltage Configuration c Maximum Voltage Configuration Execute with Test Mode : TX-PROTOCOL a Protocol b Uplink Encrypted Payload c NVM d Public Key e Frequencies Distribution f LBT Execute with Test Mode : RX-PROTOCOL a Downlink b Downlink Encrypted c Downlink Window : Start of Listening d Downlink Window : End of Listening Execute with Test Mode : RX-GFSK Execute with Test Mode : RX-SENSITIVITY Execute with Test Mode : TX-SYNTH Results 17 4 APPENDIX If you don t know the private key how to configure RSA? LBT test with ADDON RF & Protocol VERSION < 0.4.0?
4 1 Introduction This document describes the test procedure compliant with the Sigfox RF & Protocol Test Plan. 1.1 Scope This document is delivered to Device Makers to help them execute Sigfox tests before the official Sigfox RF & Protocol Tests. 1.2 Acronyms and abbreviations - 2GFSK: 2-Level Gaussian Frequency Shift Keying - ACK: Acknowledgement - AES: Advanced Encryption Standard - Att: Attenuator - CAB: Client Application Board - CBC: Cipher Block Chaining - CS: Carrier Sense - Cold Test: Test executed in initial condition (wait till the DUT come back to the initial system between two tests) - DBPSK: Differential Binary Phase-Shift Keying - DUT: Device Under Test - ENC: Encrypted - Fd: DUT Frequency - Fe: Equipment Frequency - Legacy Uplink: initial payload format of Sigfox Uplink without encryption - LBT: Listen Before Talk - NVM: Non Volatile Memory - OOB: Out Of Band - PAC: Porting Authorization Code - PER: Packet Error Rate - PMR: Private Mobile Radio - RC: Radio Configuration - RF: Radio Frequency - RSA: Radio_Signal_Analyzer - RSSI_dut: DUT RSSI - RSSI_eq: Equipment RSSI - SMIQ: Vector Signal Generator - SOC: System On Chip - Sigfox Message: Three frames with payload A3B - UNBT: Ultra Narrow Band Transceiver 3
5 1.3 Radio Signal Analyzer User guide Before starting test, read carefully the Radio_Signal_Analyzer User guide (available on Build Website: https: // build. sigfox. com ), it will be easier to use Radio_Signal_Analyzer and to find all things after that Verdict Type EVALUATION All requirements are manual verdict and have to be updated by the operator. Check each "Covered requirement" table to know the manual verdict and the "Manual Verdict" explanation to know if this verdict is "FAILED" or "PASSED". TOOL-ANALYSIS All requirements are automatic verdict and will be updated automatically by Radio_Signal_Analyzer. MEASUREMENT All measurement are automatic and will be updated automatically by RSA Checklist Information All information from the checklist have to be filled in properly before starting test. Radio_Signal_Analyzer should be configured according to the RF & Protocol Test Guide (RCx, modem type, ID/KEY values,...). Some information will be needed all test long. 4
6 2 Sigfox RF & Protocol Tests All tests below are described to help to validate some requirements for the Sigfox RF & Protocol Tests. It could help during the development, but it s not a certification. Some requirement cannot be validated with the SDR DONGLE as it is not calibrated in Power Level/ Frequency. With this equipment do not forget to keep a safe margin for all tests. All verdicts "inconclusive" (due to SDR DONGLE) have to be tested following the Sigfox Test Plan (available on Build Website: build. sigfox. com ). 2.1 Test Setup Test Setup : Connect DUT to SDR-DONGLE with 40dB attenuator Launch Radio_Signal_Analyzer Populate the "device Configuration" window "Device STATIC Configuration" : choose the Modem Type, Radio Configuration, Payload Encryption This configuration should not be modified after starting Sigfox RF & Protocol Tests. "Device DYNAMIC Configuration" : Configure your ID/KEY, (if you have operational ID/KEY and don t know the private KEY value refer to the Appendix explanations), Do not forget to fill in your oscillator values (Aging and Temperature accuracy) Select "SDR DONGLE" in the "Tester" part Click "Open" Click "Start" 5
7 LBT Test Setup : This test setup has to be used only for LBT tests Configure the signal generator at -30dB at MHz Configure the Waveform Generator according to the Carrier Sense value : Period = ( 10.2s + (CS_value_in_s )) s Duty Cycle = (1 - (10.2 / Period) ) * 100 % Connect the signal generator, the Waveform Generator and the SDR-DONGLE to the DUT through a Combiner Fill in all following information : Fill in all DUT information in "Info / Equipment / Verdicts" window ("Information" subwindow) Fill in all equipment information according to your setup in "Info / Equipment / Verdicts" window ("Equipment" subwindow), or load your equipment information file (if already saved) 2.2 Tests Execution ADJUSTABLE RF OUTPUT POWER : If the device proposed in Sigfox RF & Protocol Tests has the option to change the RF output power the Sigfox Sigfox RF & Protocol Tests has to be done twice : Once at minimum RF output power configured in the DUT (the whole Sigfox RF & Protocol Test Procedure has to be followed with this configuration). Second time at maximum RF output power configured in the DUT (the whole Sigfox RF & Protocol Test Procedure has to be followed with this configuration). Two Sigfox RF & Protocol Tests reports will be provided for this DUT. 6
8 Power Supply : If the device proposed in Sigfox RF & Protocol Tests has the minimum power supply value = nominal power supply value or maximum power supply value = nominal power supply value, the Sigfox Sigfox RF & Protocol Tests has to be done twice at the same power supply Execute with Test Mode : TX-BPSK TEST CONDITION Cold tests have to be done to validate all RF requirements, the goal is to validate the device in worst condition (before established system) a Nominal Voltage Configuration Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Nominal Voltage" Power up the DUT in Nominal Voltage Click "Raw IQ File" to start the record in the "Device" part and choose a folder Run the Sigfox Test Mode TX-BPSK with config 3 with your DUT Run the Sigfox Test Mode TX-BPSK with your DUT Click "Raw IQ File" again to stop the record Check the record size (value should be different from 0 MB) Manual Verdict : DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelop" window). Some requirements cannot be validated as the SDR DONGLE is not calibrated in frequency as Static Frequency Drift or due to equipment limitations as the "Narrow Band Power Distribution". We recommand to keep a safe margin for the Dynamic Drift for example. Covered Requirements : 7
9 Reference Requirement Verdict Type PRS-RF-PROTOCOL-13 Static Frequency Tolerance TOOL-ANALYSIS PRS-RF-PROTOCOL-20 DBPSK Modulation envelop EVALUATION PRS-RF-PROTOCOL-21 Phase Measurement TOOL-ANALYSIS PRS-RF-PROTOCOL-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-30 TX Max Symbol duration TOOL-ANALYSIS PRS-RF-PROTOCOL-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-RF-PROTOCOL-40 Power Spectral Density TOOL-ANALYSIS PRS-RF-PROTOCOL-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-RF-PROTOCOL-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-100 Modulated Conducted Output Power MEASUREMENT PRS-RF-PROTOCOL-120 I/Q Wave record TOOL-ANALYSIS b Minimum Voltage Configuration Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Minimum Voltage" Power up the DUT in Minimum Voltage Run the Sigfox Test Mode TX-BPSK with config 3 with your DUT Run the Sigfox Test Mode TX-BPSK with your DUT Manual Verdict : DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelop" window). Some requirements cannot be validated as the SDR DONGLE is not calibrated in frequency as Static Frequency Drift or due to equipment limitations as the "Narrow Band Power Distribution". We recommand to keep a safe margin for the Dynamic Drift for example. Covered Requirements : 8
10 Reference Requirement Verdict Type PRS-RF-PROTOCOL-13 Static Frequency Tolerance TOOL-ANALYSIS PRS-RF-PROTOCOL-20 DBPSK Modulation envelop EVALUATION PRS-RF-PROTOCOL-21 Phase Measurement TOOL-ANALYSIS PRS-RF-PROTOCOL-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-30 TX Max Symbol duration TOOL-ANALYSIS PRS-RF-PROTOCOL-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-RF-PROTOCOL-40 Power Spectral Density TOOL-ANALYSIS PRS-RF-PROTOCOL-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-RF-PROTOCOL-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-100 Modulated Conducted Output Power MEASUREMENT PRS-RF-PROTOCOL-120 I/Q Wave record TOOL-ANALYSIS c Maximum Voltage Configuration Ensure that your DUT is in cold test condition (Remove all USB cables and power supply) Select "Test Mode TX-BPSK" in "Device" part Select "Maximum Voltage" Power up the DUT in Maximum Voltage Run the Sigfox Test Mode TX-BPSK with config 3 with your DUT Run the Sigfox Test Mode TX-BPSK with your DUT Manual Verdict : DBPSK Modulation envelop : This test is PASSED only if the signal is modulated with amplitude level when a 0 occurs (Check the "envelop" window). Some requirements cannot be validated as the SDR DONGLE is not calibrated in frequency as Static Frequency Drift or due to equipment limitations as the "Narrow Band Power Distribution". We recommand to keep a safe margin for the Dynamic Drift for example. Covered Requirements : 9
11 Reference Requirement Verdict Type PRS-RF-PROTOCOL-13 Static Frequency Tolerance TOOL-ANALYSIS PRS-RF-PROTOCOL-20 DBPSK Modulation envelop EVALUATION PRS-RF-PROTOCOL-21 Phase Measurement TOOL-ANALYSIS PRS-RF-PROTOCOL-22 Extra symbols before the first Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-23 Extra symbols after the last Sigfox bit of the frame TOOL-ANALYSIS PRS-RF-PROTOCOL-30 TX Max Symbol duration TOOL-ANALYSIS PRS-RF-PROTOCOL-31 Max TX Baudrate Cumulated Error TOOL-ANALYSIS PRS-RF-PROTOCOL-40 Power Spectral Density TOOL-ANALYSIS PRS-RF-PROTOCOL-41 Narrow Band Power Distribution TOOL-ANALYSIS PRS-RF-PROTOCOL-50 Transitional Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-51 Established Frequency Dynamic Drift TOOL-ANALYSIS PRS-RF-PROTOCOL-100 Modulated Conducted Output Power MEASUREMENT PRS-RF-PROTOCOL-120 I/Q Wave record TOOL-ANALYSIS Execute with Test Mode : TX-PROTOCOL a Protocol Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" Power up the DUT in Nominal Voltage Configure the configword : CW[0]=0x CW[1]=0x00002EE0 CW[2]=0x Send a Sigfox Message with your DUT (payload 1 bit only : "1") Send a Sigfox Message with your DUT (payload 1 bit only : "0") Send a Sigfox Message with your DUT (payload 1 byte only : "40") Send a Sigfox Message with your DUT (payload 2 bytes only : "4041") Send a Sigfox Message with your DUT (payload 3 bytes only : "404142") Send a Sigfox Message with your DUT (payload 4 bytes only : " ") Send a Sigfox Message with your DUT (payload 5 bytes only : " ") Send a Sigfox Message with your DUT (payload 6 bytes only : " ") Send a Sigfox Message with your DUT (payload 7 bytes only : " ") Send a Sigfox Message with your DUT (payload 8 bytes only : " ") Send a Sigfox Message with your DUT (payload 9 bytes only : " ") 10
12 2.2.2.b Send a Sigfox Message with your DUT (payload 10 bytes only : " ") Send a Sigfox Message with your DUT (payload 11 bytes only : " A") Send a Sigfox Message with your DUT (payload 12 bytes only : " A4B") Send a OOB Sigfox Message with your DUT Run the Sigfox Test Mode TX-PROTOCOL with your DUT Uplink Encrypted Payload Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Protocol" Check "Activate Payload Encryption" Switch your device in encrypted mode Run the Sigfox Test Mode TX-PROTOCOL with your DUT Uncheck "Activate Payload Encryption" in "Device" part Switch your device in not-encrypted mode c NVM Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "NVMemory" Send a Sigfox Message with your DUT (payload 1 byte only) : FIRST MESSAGE with Freq1 for frame 1, freq2 for frame 2 and freq3 for frame 3 in the "demodulation window" in RSA Power down (remove all USB cables and power supply) the DUT Power up the DUT in Nominal Voltage Send a Sigfox Message with your DUT (payload 1 byte only) : SECOND MESSAGE with Freq4 for frame 1, freq5 for frame 2 and freq6 for frame 3 in the "demodulation window" in RSA 2. If ADDON RF & PROTOCOL VERSION < V0.4.0 : Send a Sigfox Message with your DUT (payload 1 byte only) : FIRST MESSAGE with Freq1 for frame 1, freq2 for frame 2 and freq3 for frame 3 in the "demodulation window" in RSA Power down (remove all USB cables and power supply) the DUT Power up the DUT in Nominal Voltage Send a Sigfox Message with your DUT (payload 1 byte only) : SECOND MESSAGE with Freq4 for frame 1, freq5 for frame 2 and freq6 for frame 3 in the "demodulation window" in RSA 3. If ADDON RF & PROTOCOL VERSION V0.4.0 : Run the Sigfox Test Mode NVM with your DUT 11
13 Power down (remove all USB cables and power supply) the DUT Power up the DUT in Nominal Voltage Run the Sigfox Test Mode NVM with your DUT Manual Verdict : If NO ADDON RF & PROTOCOL or if ADDON RF & PROTOCOL VERSION < V0.4.0 NVM Frequency Storage : After Power down/up, in the "demodulation window", the verdict should be : PASSED if freq1 is not egal to freq4 +/-100Hz, freq2 is not egal to freq5 +/-100Hz, freq3 is not egal to freq6 +/-100Hz. ("PASSED Verdict" example below). In "Demodulation" window, after power down/up, the Device (picture below) had not the same Sequence Number and same Frequencies as before. NVM requirements should be "passed" in the "Info / Equipment / Verdicts" window ("verdicts" subwindow). FAILED if freq1=freq4 +/-100Hz, freq2=freq5 +/-100Hz, freq3=freq6 +/-100Hz d Public Key Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Public Key" Switch in "public Key" in "Device Configuration", DYNAMIC part Configure the DUT in public Key Send a Sigfox Message with your DUT (payload 1 byte only) Wait for the end of the Sigfox message Switch in "private Key" in "Device Configuration", DYNAMIC part Configure the DUT in private Key 2. If ADDON RF & PROTOCOL VERSION < V0.4.0 : Configure the DUT in public Key Send a Sigfox Message with your DUT (payload 1 byte only) Wait for the end of the Sigfox message Switch in "private Key" in "Device Configuration", DYNAMIC part 12
14 Configure the DUT in private Key 3. If ADDON RF & PROTOCOL VERSION V0.4.0 : Run the Sigfox Test Mode PUBLIC-KEY with your DUT Wait for the end of the Sigfox message Switch in "private Key" in "Device Configuration", DYNAMIC part e Frequencies Distribution Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "Frequency Distribution" Run the Sigfox Test Mode TX-PROTOCOL with config 34 with your DUT Run the Sigfox Test Mode TX-FREQ-DISTRIBUTION with your DUT f LBT Read the following procedure carefully before starting your test Connect the LBT test setup (with blocker) Start the blocker Select "Test Mode TX-PROTOCOL" in "Device" part Select the Test Configuration "TX Repeat TimeOut" Run the Sigfox Test Mode TX-PROTOCOL with config 1 with your DUT Stop the Test Mode after the first 2 Sigfox Message Connect the test setup (without blocker) again 2. If ADDON RF & PROTOCOL VERSION < : This test is not possible with this ADDON RF & PROTOCOL VERSION Partner : Refer to the Appendix explanations to implement a solution and call the new test mode : TX-BIT Tester : Refer to If ADDON RF & PROTOCOL VERSION V0.4.0 : for LBT testing 3. If ADDON RF & PROTOCOL VERSION V0.4.0 : Run the Sigfox Test Mode TX-BIT with your DUT Connect the test setup (without blocker) again Covered Requirements : 13
15 Reference Requirement Verdict Type PRS-RF-PROTOCOL-11 Operational Frequencies Range TOOL-ANALYSIS PRS-RF-PROTOCOL-12 Operational Frequencies Distribution TOOL-ANALYSIS PRS-RF-PROTOCOL-80 AES TOOL-ANALYSIS PRS-RF-PROTOCOL-81 NVM Frequency Storage TOOL-ANALYSIS PRS-RF-PROTOCOL-82 NVM Sequence Number Storage TOOL-ANALYSIS PRS-RF-PROTOCOL-83 Public Key switch TOOL-ANALYSIS PRS-RF-PROTOCOL-84 Number of frames per message in Uplink mode TOOL-ANALYSIS PRS-RF-PROTOCOL-85 Legacy Uplink TOOL-ANALYSIS PRS-RF-PROTOCOL-86 Uplink Encrypted payload TOOL-ANALYSIS PRS-RF-PROTOCOL-90 TX Interframe Timing in Uplink mode TOOL-ANALYSIS PRS-RF-PROTOCOL-91 TX repeat timeout TOOL-ANALYSIS PRS-RF-PROTOCOL-111 DUT Temperature level MEASUREMENT PRS-RF-PROTOCOL-112 DUT Voltage level MEASUREMENT Execute with Test Mode : RX-PROTOCOL a Downlink Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Standard Downlink" Run the Sigfox Test Mode RX-PROTOCOL with config 1 with your DUT Run the Sigfox Test Mode RX-PROTOCOL with your DUT We recommand to keep a margin (middle of the allowed timings : between 1.4 and 4 s) as the measurement with the SDR-DONGLE is not really accurate. Some requirements cannot be validated as the SDR DONGLE is not calibrated in power level (as RSSI level). Both results need to be passed for final verdict. RSA displays the final verdict but only the last measurement is reported in RSA result column. Example : If the first measurement is failed and the second passed, the final verdict will be failed with only the second measurement displays in RSA b Downlink Encrypted Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Standard Downlink" 14
16 Check "Activate Payload Encryption" Switch your device in encrypted mode Run the Sigfox Test Mode RX-PROTOCOL with your DUT Uncheck "Activate Payload Encryption" in "Device" part Switch your device in not-encrypted mode c Downlink Window : Start of Listening Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "Start of Listening Window" Run the Sigfox Test Mode RX-PROTOCOL with config 1 with your DUT Run the Sigfox Test Mode RX-PROTOCOL with your DUT d Downlink Window : End of Listening Select "Test Mode RX-PROTOCOL" in "Device" part Select the Test Configuration "End of Listening Window" Run the Sigfox Test Mode RX-PROTOCOL with config 1 with your DUT Run the Sigfox Test Mode RX-PROTOCOL with your DUT Covered Requirements : Reference Requirement Verdict Type PRS-RF-PROTOCOL-87 Downlink Legacy TOOL-ANALYSIS PRS-RF-PROTOCOL-88 Downlink Encrypted Payload TOOL-ANALYSIS PRS-RF-PROTOCOL-89 Number of Uplink frame in bi-directional mode TOOL-ANALYSIS PRS-RF-PROTOCOL-92 TX Interframe Timing in Bi-directional mode TOOL-ANALYSIS PRS-RF-PROTOCOL-93 RX Start Of Listening TOOL-ANALYSIS PRS-RF-PROTOCOL-94 RX End Of Listening TOOL-ANALYSIS PRS-RF-PROTOCOL-95 RX to OOB(ack) Timing TOOL-ANALYSIS PRS-RF-PROTOCOL-110 RSSI level TOOL-ANALYSIS 15
17 2.2.4 Execute with Test Mode : RX-GFSK The "static Drift (Hz)" will be updated automatically by RSA according to the Test Mode : TX-BPSK static drift result. Select "Test Mode RX-GFSK" in "Device" part Click "Start Send GFSK" in "Device" part Run the Sigfox Test Mode RX-GFSK with config 30 with your DUT Check the GFSK reporting and the RSSI value returned Click "Stop Send GFSK" in "Device" part Run the Sigfox Test Mode RX-GFSK with your DUT Check the GFSK reporting and the RSSI value returned Click "Stop Send GFSK" in "Device" part The RX-GFSK level cannot be validated with the SDR-DONGLE (fixed level) but this test allows to validate the test mode RX-GFSK functionality. Manual Verdict : 2GFSK 600bps : This test is PASSED only if the DUT receives GFSK sent by Radio_Signal_Analyzer and reports the test result. Downlink Only-rssi : This test is PASSED only if the RSSI value displayed is GFSK RSSI +/- 2 db. Covered Requirements : Reference Requirement Verdict Type PRS-RF-PROTOCOL-60 2GFSK 600bps EVALUATION PRS-RF-PROTOCOL-61 Downlink Only-rssi EVALUATION Execute with Test Mode : RX-SENSITIVITY Select "Test Mode RX-SENSI" in "Device" part Run the Sigfox Test Mode RX-SENSI with config 100 with your DUT Run the Sigfox Test Mode RX-SENSI with your DUT The sensitivity cannot be validated with the SDR-DONGLE (fixed level) but this test allows to validate the test mode RX-SENSITIVITY functionality. 16
18 Covered Requirements : Reference Requirement Verdict Type PRS-RF-PROTOCOL-70 Sigfox Link Budget TOOL-ANALYSIS Execute with Test Mode : TX-SYNTH Select "Test Mode TX-SYNTH" in "Device" part Run the Sigfox Test Mode TX-SYNTH with config 0 with your DUT Stop the Test Mode after 10 frames Run the Sigfox Test Mode TX-SYNTH with your DUT Covered Requirements : Reference Requirement Verdict Type PRS-RF-PROTOCOL-10 Frequency Steps TOOL-ANALYSIS 3 Results Be careful, when saving the measurement, the result folder will be cleared. For all manual verdicts, add a note and/or a value in the comment part. If the manual verdict is fail, add a note in the comment part to explain why (for example : The command doesn t work). Export results when all requirements have been tested (all verdicts should be "FAIL", "INFO" or "PASS") : In "Info / Equipment / Verdicts" window, Choose "Export Results" Open the result folder Select your DUT picture Select the I/Q record Select the RF & Protocol Test Guide The sigfoxrfandprotocol.tar.gz will contain all information (verdicts, comments, information) and shouldn t be modified in any way. All verdicts : "INCONCLUSIVE", cannot be validate with this equipment (due to the equipment s limitation). 17
19 4 APPENDIX 4.1 If you don t know the private key how to configure RSA? This specific test setup is applicable only in case of old library and is not recommended as operational mode cannot be fully validated. Configure RSA without Private KEY value if operational ID/KEY The device proposed in Sigfox RF & Protocol Tests must have ID/KEY test values. However if the device is based on old library version it s possible to test in public KEY : Switch the DUT in public KEY In "Device DYNAMIC Configuration" Replace the default ID value by your operational ID value In "Device DYNAMIC Configuration" Choose "Private key" and Replace the default KEY value by 0x AABBCCDDEEFF Do not change this configuration during the whole procedure except for the specific Public Key test part 4.2 LBT test with ADDON RF & Protocol VERSION < 0.4.0? This specific test is not possible with ADDON RF & Protocol VERION < Partner has to provide a way to test it : If SIGFOX LIBRARY VERSION > : update your ADDON RF & Protocol VERSION (contact Sigfox) Implement the test mode following Sigfox RF & Protocol Test Plan explanations (Build Website: https: // build. sigfox. com ) If SIGFOX LIBRARY VERSION < : update your SIGFOX LIBRARY VERSION and your ADDON RF & Protocol VERSION (contact Sigfox) 18
Sigfox Verified TM. Test Procedure RSA-SDR-DONGLE for RC1-UDL-ENC. Version April 24, Public Use
Version 3.6.0 April 24, 2018 Sigfox Verified TM Test Procedure RSA-SDR-DONGLE for RC1-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationSigfox Verified TM. Modem Test Plan for RC5-UDL-ENC. Version August 10, Public Use
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Test Plan for RC5-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox Verified TM. Modem Test Plan for RC2-UDL-ENC. Version April 24, Public Use
Version 3.6.0 April 24, 2018 Sigfox Verified TM Modem Test Plan for RC2-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox RF & Protocol Test Plan for RC3c-UDL-ENC
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Test Plan for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationSigfox RF & Protocol Test Plan for RC2-UDL-ENC
Version 380 September 14, 2018 Sigfox RF & Protocol Test Plan for RC2-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable This document
More informationSigfox RF & Protocol Test Plan for RC1-UDL-ENC-MONARCH
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Test Plan for RC1-UDL-ENC-MONARCH Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationBe prepared for Sigfox Verified TM Certification
Version 3.7.1 August 10, 2018 Be prepared for Sigfox Verified TM Certification Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This
More informationBe prepared for Sigfox Verified TM Certification
Version 3.2.3 September 22, 2017 Be prepared for Sigfox Verified TM Certification Public Use Contents 1 Introduction 2 1.1 Scope...................................................... 3 1.2 Acronyms and
More informationSigfox RF & Protocol Specifications for RC3c-UDL-ENC
Version 3.8.0 September 14, 2018 Sigfox RF & Protocol Specifications for RC3c-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationModem Specification for RC4-UDL-ENC
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Specification for RC4-UDL-ENC Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationModem Specification for RC5-UDL-NOTENC-REP
Version 3.7.1 August 10, 2018 Sigfox Verified TM Modem Specification for RC5-UDL-NOTENC-REP Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable.
More informationSIGFOX_VERIFIED ULTRA NARROW BAND
_VERIFIED ULTRA NARROW BAND _VERIFIED ULTRA NARROW BAND MODEM REQUIREMENTS SPECIFICATION FOR NOTICE: THE CONTENT OF THIS DOCUMENT IS THE AND SHALL NOT BE DISCLOSED, DISSEMINATED, COPIED, OR USED EXCEPT
More informationSIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION
October 5 th 2017 SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION Public use Revision History Revision Number Date Author Change description 0.1 August 15 th, 2017 B.Ray Initial
More informationBE PREPARED FOR SIGFOX READY TM CERTIFICATION
May 18th 2018 BE PREPARED FOR SIGFOX READY TM CERTIFICATION Public use Revision History Revision Number Date Change description 0.1 August 15 th, 2017 Initial spec 0.2 May 18 th, 2018 CW test time Content
More informationSV613 USB Interface Wireless Module SV613
USB Interface Wireless Module SV613 1. Description SV613 is highly-integrated RF module, which adopts high performance Si4432 from Silicon Labs. It comes with USB Interface. SV613 has high sensitivity
More informationDragonLink Advanced Transmitter
DragonLink Advanced Transmitter A quick introduction - to a new a world of possibilities October 29, 2015 Written by Dennis Frie Contents 1 Disclaimer and notes for early release 3 2 Introduction 4 3 The
More informationRF Basics 15/11/2013
27 RF Basics 15/11/2013 Basic Terminology 1/2 dbm is a measure of RF Power referred to 1 mw (0 dbm) 10mW(10dBm), 500 mw (27dBm) PER Packet Error Rate [%] percentage of the packets not successfully received
More informationCatalog
- 1 - Catalog 1. Overview...- 3-2. Feature... - 3-3. Application...- 3-4. Block Diagram...- 3-5. Electrical Characteristics... - 4-6. Operation... - 4-1) Power on Reset... - 4-2) Sleep mode... - 4-3) Working
More informationUSB Port Medium Power Wireless Module SV653
USB Port Medium Power Wireless Module SV653 Description SV653 is a high-power USB interface integrated wireless data transmission module, using high-performance Silicon Lab Si4432 RF chip. Low receiver
More informationPXI WiMAX Measurement Suite Data Sheet
PXI WiMAX Measurement Suite Data Sheet The most important thing we build is trust Transmit power Spectral mask Occupied bandwidth EVM (all, data only, pilots only) Frequency error Gain imbalance, Skew
More informationGetting Started Guide
MaxEye IEEE 0.15.4 UWB Measurement Suite Version 1.0.0 Getting Started Guide 1 Table of Contents 1. Introduction... 3. Installed File Location... 3 3. Programming Examples... 4 3.1. 0.15.4 UWB Signal Generation...
More information3 Definitions, symbols, abbreviations, and conventions
T10/02-358r2 1 Scope 2 Normative references 3 Definitions, symbols, abbreviations, and conventions 4 General 4.1 General overview 4.2 Cables, connectors, signals, transceivers 4.3 Physical architecture
More informationCatalog
- 1 - Catalog 1. Overview... - 3-2. Feature...- 3-3. Application... - 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 4-1) Power on Reset... - 4-2) Sleep mode...- 4-3) Working
More informationDoes The Radio Even Matter? - Transceiver Characterization Testing Framework
Does The Radio Even Matter? - Transceiver Characterization Testing Framework TRAVIS COLLINS, PHD ROBIN GETZ 2017 Analog Devices, Inc. All rights reserved. 1 Which cost least? 3 2017 Analog Devices, Inc.
More informationTestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board
Page 1 of 16 ========================================================================================= TestData Summary of 5.2GHz WLAN Direct Conversion RF Transceiver Board =========================================================================================
More informationG3P-R232. User Manual. Release. 2.06
G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...
More informationSystem Specification. EnOcean Certification Specification, part 1a Air Interface (ASK) V 1.1, RELEASED EXECUTIVE SUMMARY
EnOcean Certification Specification, part 1a Air Interface (ASK) V 1.1, RELEASED Approved for release: Sep 14, 2017 San Ramon, CA, USA, Dec 17, 2013 EXECUTIVE SUMMARY A proper review of every device shipped
More informationOPP;SLARSEN;MVO;JFR;SSE;CRASMUSSEN;BBR BBR;CRASMUSSEN;MHANSEN;JFR. Date CET Initials Name Justification
Instruction Micro RF LinkX for 500 Series Document No.: INS12880 Version: 9 Description: The purpose of this document is to describe how to use the test tool Micro RF LinkX on devices based on the 500-series
More information0.6 kbits/s, the modulation shall be aviation binary phase shift keying (A-BPSK).
SECTION 3 RF CHANNEL CHARACTERISTICS 3.1 Modulation 3.1.1 Modulation for channel rates 2.4 kbits/s and below. For channel rates of 2.4, 1.2 and 0.6 kbits/s, the modulation shall be aviation binary phase
More informationEmbedded Radio Data Transceiver SV611
Embedded Radio Data Transceiver SV611 Description SV611 is highly integrated, multi-ports radio data transceiver module. It adopts high performance Silicon Lab Si4432 RF chip. Si4432 has low reception
More informationRF TESTING OF MODEMS EMBEDDED IN RADIOS
RF TESTING OF MODEMS EMBEDDED IN RADIOS J. W. Nieto Senior Scientist Harris Corporation RF Communications Division HFIA 2002, #1 Presentation Overview Overview Motivation Baseband Testing RF Testing RF
More informationBasic Transceiver tests with the 8800S
The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS Basic Transceiver tests with the 8800S Basic Interconnects Interconnect
More informationGetting Started Guide
MaxEye ZigBee (IEEE 802.15.4) Measurement Suite Version 1.0.5.3 Getting Started Guide Table of Contents 1. Introduction...3 2. Installed File Location...3 3. Soft Front Panel...5 3.1 MaxEye ZigBee Signal
More information4. BK2401/BK2421 Module RF test
4. BK2401/BK2421 Module RF test BK2401/BK2421 Module RF performance tests including transmit power (Power) Frequency (Frequency) and sensitivity (Sensitivity) test, and FCC / CE testing major FAIL in the
More informationLoRaWAN. All of the gateways in a network communicate to the same server, and it decides which gateway should respond to a given transmission.
LoRaWAN All of the gateways in a network communicate to the same server, and it decides which gateway should respond to a given transmission. Any end device transmission can be heard by multiple receivers,
More informationetatronix PMA-3 Transmitter Tester Manual
etatronix PMA-3 Transmitter Tester Manual TxTester_Manual_rev1.02.docx 1 Version Version Status Changes Date Responsible 1 Release Initial release 01. Apr. 2015 CW 1.01 Release Updated Figure 4 for better
More informationPXI LTE FDD and LTE TDD Measurement Suites Data Sheet
PXI LTE FDD and LTE TDD Measurement Suites Data Sheet The most important thing we build is trust A production ready ATE solution for RF alignment and performance verification UE Tx output power Transmit
More informationMicro Fox PicCon Manual
Micro Fox PicCon Manual Version 0.61 The Micro Fox PicCon (MF PC) is a 700mW fox hunting/hidden transmitter hunt transceiver. It can be configured and remotely controlled via DTMF tones, and also be configured
More informationRadiocrafts Embedded Wireless Solutions
High Performance RF Module for SIGFOX 868MHz Product Description The module is a compact surface-mounted product that measures only 12.7 x 25.4 x 3.5 mm. The module contains a communication controller
More informationTriarchy VSG6G1C USB Vector RF Signal Generator Operating Manual
Triarchy VSG6G1C USB Vector RF Signal Generator Operating Manual CW signal NB RF noise generator Analog modulation GMSK modulation Frequency sweeping Hopping with data Mod Page 1 of 27 8PSK GSM signal
More informationCatalogue
- 1 - Catalogue 1. Description... - 3-2. Features... - 3-3. Applications...- 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 5 - Power on Reset... - 5 - Working mode... -
More informationMulti-Channel RS-232 Serial RF Transceiver
RF-232 Multi-Channel RS-232 Serial RF Transceiver The RF-232 subassembly is a multi-channel serial radio transceiver. This device accepts and outputs standard serial data at one of three selectable data
More informationWireless LAN Consortium OFDM Physical Layer Test Suite v1.6 Report
Wireless LAN Consortium OFDM Physical Layer Test Suite v1.6 Report UNH InterOperability Laboratory 121 Technology Drive, Suite 2 Durham, NH 03824 (603) 862-0090 Jason Contact Network Switch, Inc 3245 Fantasy
More informationSV-MESH Mesh network series Catalogue
Catalogue 1. Description... 3 2. Features... 3 3. Applications... 3 4. Block Diagram... 4 5. Electrical Characteristics... 5 6. Operation... 5 Power on Reset... 5 Working mode... 6 Router mode... 8 Setting
More informationLABORATORY EXERCISES
LABORATORY EXERCISES You can write the answers on this sheet, or use a separate sheet if necessary. The deadline for returning these exercises can be seen on the course web page. If you run into problems,
More informationANT Channel Search ABSTRACT
ANT Channel Search ABSTRACT ANT channel search allows a device configured as a slave to find, and synchronize with, a specific master. This application note provides an overview of ANT channel establishment,
More informationETHERNET TESTING SERVICES
ETHERNET TESTING SERVICES 10BASE-Te Embedded MAU Test Suite Version 1.1 Technical Document Last Updated: June 21, 2012 Ethernet Testing Services 121 Technology Dr., Suite 2 Durham, NH 03824 University
More informationELECTRICAL TESTING
ELECTRICAL TESTING 0839.01 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com TEST REPORT ACCORDING TO: FCC
More information1 UAT Test Procedure and Report
1 UAT Test Procedure and Report These tests are performed to ensure that the UAT Transmitter will comply with the equipment performance tests during and subsequent to all normal standard operating conditions
More informationBuilding an Efficient, Low-Cost Test System for Bluetooth Devices
Application Note 190 Building an Efficient, Low-Cost Test System for Bluetooth Devices Introduction Bluetooth is a low-cost, point-to-point wireless technology intended to eliminate the many cables used
More information2320 cousteau court
Technical Brief AN139 Rev C22 2320 cousteau court 1-760-444-5995 sales@raveon.com www.raveon.com RV-M7 GX with TDMA Data By John Sonnenberg Raveon Technologies Corporation Overview The RV-M7 GX radio modem
More informationISO/IEC INTERNATIONAL STANDARD
INTERNATIONAL STANDARD This is a preview - click here to buy the full publication ISO/IEC 24769-5 First edition 2012-12-15 Corrected version 2012-12-15 Information technology Automatic identification and
More informationResearch on key digital modulation techniques using GNU Radio
Research on key digital modulation techniques using GNU Radio Tianning Shen Yuanchao Lu I. Introduction Software Defined Radio (SDR) is the technique that uses software to realize the function of the traditional
More informationTC-3000C Bluetooth Tester
TC-3000C Bluetooth Tester Product Instructions TC-3000C Bluetooth Tester is able to analyze the data of every packet that is transmitted to the upper application protocol layer using the protocol stack,
More informationPower Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master
Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak
More informationApplication Note: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers
: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers FCT-1007A Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for the radio
More informationAN12165 QN908x RF Evaluation Test Guide
Rev. 1 May 2018 Application note Document information Info Keywords Abstract Content GFSK, BLE, RF, Tx power, modulation characteristics, frequency offset and drift, frequency deviation, sensitivity, C/I
More informationVST 6 GHz RF Vector Signal Transceiver (VST)
VST 6 GHz RF Vector Signal Transceiver (VST) 2016 Datasheet The most important thing we build is trust Key features Vector signal analyser and generator in a single 3U x 3 slot wide PXIe module 65 MHz
More informationTesting Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer
Testing Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer Page 1 of 24 Motorola CPS and Tuner Software Motorola provides a CD containing software programming facilities for
More informationSTANAG 4529 CONFORMANCE TEST PROCEDURES
DEFENSE INFORMATION SYSTEMS AGENCY JOINT INTEROPERABILITY TEST COMMAND FORT HUACHUCA, ARIZONA STANAG 4529 CONFORMANCE TEST PROCEDURES APRIL 2004 Downloaded from http://www.everyspec.com (This page intentionally
More informationVARA HF Modem Specification Revision Oct30, 2017 Jose Alberto Nieto Ros, EA5HVK
VARA HF Modem Specification Revision 1.0.0 Oct30, 2017 Jose Alberto Nieto Ros, EA5HVK 1.0 Overview: VARA HF Modem is a propietary system developed by Jose Alberto Nieto Ros EA5HVK and can be used under
More informationRadio Frequency. Core System Package Part A. Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.
Core System Package Part A Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.0 + EDR This document defines the TSS and TP for qualification testing of the Bluetooth Wireless
More informationSDR 4++ Dual Diversity SDR Receiver. Operating Guide. version 1.0
Cross Country Wireless, 7 Thirlmere Grove, BOLTON, BL4 0QB, UK Email chrism@crosscountrywireless.net Web page http://www.crosscountrywireless.net Telephone +44 (0) 1204 410626 Mobile / Workshop +44 (0)
More informationKeysight Technologies Performing LTE and LTE-Advanced RF Measurements with the E7515A UXM Wireless Test Set
Keysight Technologies Performing LTE and LTE-Advanced RF Measurements with the E7515A UXM Wireless Test Set Based on 3GPP TS 36.521-1 Application Note 02 Keysight Performing LTE and LTE-Advanced Measurements
More informationinstruction manual for Open LRS New Generation
instruction manual for Open LRS New Generation Table of contents 1. Important warnings 2. Hardware Overview 3 2.1 DTF UHF 4 Channel 4 2.2 HobbyKing RX 5 3. Instructions 3.1 Basic functions 6 3.2 Flashing
More informationLab 1: Analog Modulations
Lab 1: Analog Modulations Due: October 11, 2018 This lab contains two parts: for the first part you will perform simulation entirely in MATLAB, for the second part you will use a hardware device to interface
More informationAN797 WDS USER S GUIDE FOR EZRADIO DEVICES. 1. Introduction. 2. EZRadio Device Applications Radio Configuration Application
WDS USER S GUIDE FOR EZRADIO DEVICES 1. Introduction Wireless Development Suite (WDS) is a software utility used to configure and test the Silicon Labs line of ISM band RFICs. This document only describes
More informationSignal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features
Signal Forge TM Signal Forge 1000 TM Synthesized Signal Generator L 8.5 W 5.4 H 1.5 Digital and RF Tester with 1 GHz Range The Signal Forge 1000 combines a 1 GHz frequency range with three dedicated outputs
More informationLeCroy UWBSpekChek WiMedia Compliance Test Suite User Guide. Introduction
LeCroy UWBSpekChek WiMedia Compliance Test Suite User Guide Version 3.10 March, 2008 Introduction LeCroy UWBSpekChek Application The UWBSpekChek application operates in conjunction with the UWBTracer/Trainer
More informationPXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer
SPECIFICATIONS PXIe-5668 14 GHz and 26.5 GHz Vector Signal Analyzer These specifications apply to the PXIe-5668 (14 GHz) Vector Signal Analyzer and the PXIe-5668 (26.5 GHz) Vector Signal Analyzer with
More informationETHERNET TESTING SERVICES
ETHERNET TESTING SERVICES 10BASE-T Embedded MAU Test Suite Version 5.4 Technical Document Last Updated: June 21, 2012 Ethernet Testing Services 121 Technology Dr., Suite 2 Durham, NH 03824 University of
More informationPN9000 PULSED CARRIER MEASUREMENTS
The specialist of Phase noise Measurements PN9000 PULSED CARRIER MEASUREMENTS Carrier frequency: 2.7 GHz - PRF: 5 khz Duty cycle: 1% Page 1 / 12 Introduction When measuring a pulse modulated signal the
More informationTEST REPORT OF THE. Inventek Systems
TEST REPORT OF THE 2.4 GHz es-wifi Module Models: IN CONFORMANCE WITH ETSI EN 300 328 V2.1.1 (2016-11) Harmonized EN covering essential requirements under article 3.2 of the Radio Equipment Directive (RED)
More informationMobile WiMAX Manufacturing Test with the N8300A
Mobile WiMAX Manufacturing Test with the N8300A The First Steps Towards Test Automation Application Note Table of Contents Introduction......................................... 3 The challenge............................................
More informationIQgig-RF TM Model B Technical Specifications
TECHNICAL SPECIFICATIONS IQgig-RF TM Model B Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-RF Test Controller Front Panel I/O Function Type Power
More informationAT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications
AT-XTR-7020A-4 Multi-Channel Micro Embedded Transceiver Module The AT-XTR-7020A-4 radio data transceiver represents a simple and economical solution to wireless data communications. The employment of an
More informationC Mono Camera Module with UART Interface. User Manual
C328-7221 Mono Camera Module with UART Interface User Manual Release Note: 1. 16 Mar, 2009 official released v1.0 C328-7221 Mono Camera Module 1 V1.0 General Description The C328-7221 is VGA camera module
More informationIQgig-IF TM Technical Specifications
TECHNICAL SPECIFICATIONS IQgig-IF TM Technical Specifications 2018 LitePoint, A Teradyne Company. All rights reserved. Port Descriptions IQgig-IF Front Panel I/O Function Type Power Switch Power On/Off
More informationMicroFox2 Manual. Version 0.5 August 28, 2017
Overview The Byonics MicroFox2 (MF2) is a small, 500mW, frequency agile 2-meter transceiver designed for hidden transmitter hunts, also called T-hunts, foxhunts, and ARDF. It is based on the Byonics MicroFox-PicCon,
More informationUSER'S MANUAL. Model : K
USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include
More informationCatalog
- 1 - Catalog 1. Description...- 3-2. Features...- 3-3. Applications... - 3-4. Block Diagram...- 3-5. Electrical Characteristics... - 5-6. Operation... - 5 - Power on Reset... - 5 - Working mode... - 6
More informationWiMOD LR Base Plus Firmware
WiMOD LR Base Plus Firmware Feature Specification Version 1.0 Document ID: 4000/40140/0137 IMST GmbH Carl-Friedrich-Gauß-Str. 2-4 47475 KAMP-LINTFORT GERMANY Overview Document Information File name WiMOD_LR_Base_Plus_Feature_Spec.docx
More informationAgilent N5411A Serial ATA Electrical Performance Validation and Compliance Software Release Notes
Agilent N5411A Serial ATA Electrical Performance Validation and Compliance Software Release Notes Agilent N5411A Software Version 2.60 Released Date: 7 Nov 2008 Minimum Infiniium Oscilloscope Baseline
More informationVIAVI VST. Data Sheet. 6 GHz RF Vector Signal Transceiver (VST)
Data Sheet VIAVI 6 GHz RF Vector Signal Transceiver () VIAVI Solutions The Vector Signal Transceiver () is an essential building block in RF communications test solutions supplied by VIAVI Solutions. Overview
More informationSeptember, Submission. September, 1998
Summary The CCK MBps Modulation for IEEE 802. 2.4 GHz WLANs Mark Webster and Carl Andren Harris Semiconductor CCK modulation will enable MBps operation in the 2.4 GHz ISM band An interoperable preamble
More informationSYSTEM SENSOR WIRELESS REMOTE INDICATOR PRODUCT SPECIFICATION
Model name: M200I-RF Introduction: The 200 Series Commercial RF System is designed for use with compatible intelligent fire systems using the System Sensor 200/500 Series CLIP, Enhanced and Advanced communication
More informationW5500 Compliance Test Report
W5500 Compliance Test Report Version 1.0.0 http://www.wiznet.co.kr Copyright 2015 WIZnet Co., Ltd. All rights reserved. Table of Contents 1 802.3 10Base-T compliance tests... 5 1.1 Overview... 5 1.2 Testing
More informationnrf Performance Test Instructions nrf24l01+ Application Note
nrf Performance Test Instructions nrf24l01+ Application Note All rights reserved. Reproduction in whole or in part is prohibited without the prior written permission of the copyright holder. November 2008
More informationRF Test Report. Report No.: AGC EE10. TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 STANDARD(S) : EN V : V1.
Page 1 of 49 RF Test Report Report No.: AGC05278160201EE10 TEST NAME : 1999/5/EC R&TTE Directive Art.3.2 PRODUCT DESIGNATION : ihere3.0 BRAND NAME : ihere3.0 MODEL NAME : ihere3.0 CLIENT : No NDA Inc.
More informationTransceiver. Quick Start Guide. What is in the box What does it do How to build a setup Verification of the setup...
Transceiver Quick Start Guide What is in the box... 3 What does it do... 5 How to build a setup... 6 Verification of the setup... 10 Help and troubleshooting... 11 Technical specifications... 12 Declaration
More informationLaboratory 5: Spread Spectrum Communications
Laboratory 5: Spread Spectrum Communications Cory J. Prust, Ph.D. Electrical Engineering and Computer Science Department Milwaukee School of Engineering Last Update: 19 September 2018 Contents 0 Laboratory
More informationPGT313 Digital Communication Technology. Lab 3. Quadrature Phase Shift Keying (QPSK) and 8-Phase Shift Keying (8-PSK)
PGT313 Digital Communication Technology Lab 3 Quadrature Phase Shift Keying (QPSK) and 8-Phase Shift Keying (8-PSK) Objectives i) To study the digitally modulated quadrature phase shift keying (QPSK) and
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More informationLab 1: Analog Modulations
Lab 1: Analog Modulations October 20, 2017 This lab contains two parts: for the first part you will perform simulation entirely in MATLAB, for the second part you will use a hardware device to interface
More informationSignal Generators for Anritsu RF and Microwave Handheld Instruments
Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis
More informationClause 71 10GBASE-KX4 PMD Test Suite Version 0.2. Technical Document. Last Updated: April 29, :07 PM
BACKPLANE CONSORTIUM Clause 71 10GBASE-KX4 PMD Test Suite Version 0.2 Technical Document Last Updated: April 29, 2008 1:07 PM Backplane Consortium 121 Technology Drive, Suite 2 Durham, NH 03824 University
More informationRF Wireless Serial Device Server
RF-SDS RF Wireless Serial Device Server The RF-SDS subassembly is a radio transceiver acting as a Serial Device Server, which externally connects a remote serial RF transceiver to an Ethernet network (TCP/IP).
More information2009 CubeSat Developer s Workshop San Luis Obispo, CA
Exploiting Link Dynamics in LEO-to-Ground Communications 2009 CubeSat Developer s Workshop San Luis Obispo, CA Michael Caffrey mpc@lanl.gov Joseph Palmer jmp@lanl.gov Los Alamos National Laboratory Paper
More informationF6052 Universal Time Synchronizer
F6052 Universal Time Synchronizer Doble Engineering Company March 2014 2013 Doble Engineering Company. All Rights Reserved 1 2013 Doble Engineering Company. All Rights Reserved History of Portable Time
More informationSMARTALPHA RF TRANSCEIVER
SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design
More information