empcr Amplification Method Manual Lib L LV

Size: px
Start display at page:

Download "empcr Amplification Method Manual Lib L LV"

Transcription

1 empcr Amplification Method Manual Lib L LV GS FLX+ Series XL+ May 2011 For life science research only. Not for use in diagnostic procedures. Instrument / Kit GS Junior / Junior GS FLX+ / XL+ GS FLX+ / XLR70 GS FLX / XLR70

2 1. WORKFLOW Preparation of the Reagents and of the Emulsion Oil (section 3.1) Preparation of the Reagents Approx. Time The emulsion-based clonal amplification (empcr amplification) of a DNA library sample involves 7 major steps, described in Figure 1. Variants of this procedure exist to accommodate different types of DNA libraries and different number of beads requirements for the experiment. The method described in this manual is for Rapid libraries (Lib-L) from the GS FLX+ Series and for Large Volume emulsions (LV). 1 Preparation of the Emulsion Oil Preparation of the Mock Amplification Mix and Pre-Emulsions Preparation of the Live Amplification Mix 1-2 h Preparation of the Emulsions and Amplification Kit Part A This method is to amplify libraries that will be sequenced on the GS FLX+ Instrument, using a GS FLX Titanium Sequencing Kit XL DNA Library Capture (section 3.2) Emulsification (section 3.3) Amplification (section 3.4) Dispensing the Emulsions 4 Amplification Reaction Bead Recovery (section 3.5) 8 h Amplification Reaction; Bead Recovery and Enrichment Vacuum-Assisted Emulsion Breaking Set Up Kit Part B 5 Emulsion Collection and Initial Washes Bead Washes and Recovery DNA Library Bead Enrichment (section 3.6) Preparation for Enrichment 4 5 h 6 Preparation of the Enrichment Beads Enrichment of the DNA-Carrying Beads Collection of the Enriched DNA Beads 7 Sequencing Primer Annealing (section 3.7) Figure 1: Workflow of the empcr Amplification method GS FLX+ Series XL+ 2 / 12 May 2011

3 2. BEFORE YOU BEGIN Room temperature is + 15 to + 25 C. 2.1 Sample Handling Strategy for Large Volume Emulsions Figure 2 shows sample handling in the large volume emulsion. 1 GS FLX Titanium LV empcr Kit (Lib-L) 1 GS FLX Titanium empcr Breaking Kit. LV/MV, 12 pcs Total of 2 emulsion cups 2 samples (1 Emulsion Cup each) FOR EACH SAMPLE (x 2) PCR Plate 1 ~90 wells 1 x Emulsion Cup PCR Plate 2 ~90 wells 2.2 Determining the Amount of Library to Use in empcr Amplification To clonally amplify the library, the optimal amount of DNA to add to the Capture Beads must be determined using one of two titration options. The simplest and less time consuming option is the emulsion titration, which consists of using the % of bead enrichment as an indicator of the sequencing quality. This is achieved by performing empcr amplifications on various amounts of library DNA and determining the % of enriched beads. The more involved option is the Sequencing titration, which consists of sequencing the test samples obtained after an emulsion titration. Both options are described in detail in the GS FLX+ Series XL+. empcr Amplification Method Manual Lib-L SV Refer to this manual for the procedures. However, if the library yield can be predicted from past experience, one can use a predetermined number of DNA molecules per bead. 2.3 Library Requirements The library processed through empcr Amplification should be: 1. free of small DNA species 2. with appropriate 454 Adaptors on both ends for the emulsion format used 3. properly quantified, and diluted such that at least 1 µl will be pipetted 4. composed of fragments whose lengths are compatible with the empcr Amplification method used 2 x 50 ml Collection Tubes 2 x 1.7 ml Collection Tubes 1 Seq Primer Tube 2 regions gasket (Large) Figure 2: Sample handling for Large volume emulsions GS FLX+ Series XL+ 3 / 12 May 2011

4 3. PROCEDURE 3.1 Preparation of the Reagents and of the Emulsion Oil Preparation of the Reagents 1. Open the empcr Reagents box and thaw the kit components at room temperature, except the enzymes which should be kept at -15 to -25 C. Once thawed, vortex for 5 seconds. 2. Vortex and heat the tube of empcr Additive at 55ºC for 15 minutes to aid dissolving. If a precipitate persists, centrifuge the tube and use the supernatant. 3. Spin all the kit components (including enzymes) in a bench top mini centrifuge for 10 seconds. 4. Return the enzymes to -15 to -25 C. The other kit reagents can be left at room temperature Preparation of the Emulsion Oil Rattling sound: If the TissueLyser makes a loud rattling sound, turn it off immediately and make sure that both cups and adapters are screwed tightly in place. 1. Install the cups of Emulsion Oil securely in the TissueLyser, using the GS FLX Titanium empcr Shaker Adapters, LV, provided as accessories to your GS FLX+ Instrument. 2. Shake the Emulsion Oil at 28 Hz for 2 minutes. 3. Remove the shaken Emulsion Oil from the TissueLyser Preparation of the Mock Amplification Mix and Pre-Emulsions 1. Dilute 2 ml of 5x Mock Amplification Mix with 8 ml of Molecular Biology Grade Water to make a working solution. Vortex. 2. Add 5 ml of the Mock Amplification Mix working solution to each cup of Emulsion Oil. 3. Invert the cups 2-3 times to mix, place on the TissueLyser, and secure firmly. 4. Shake in the TissueLyser at 28 Hz for 5 minutes. 5. Remove the emulsions cups from the TissueLyser Preparation of the Live Amplification Mix empcr amplification of Paired End libraries: Paired End libraries (20 kb, 8 kb and 3 kb Span) are amplified following the GS FLX Titanium Series methods and the corresponding kits. Refer to the empcr Method Manuals Lib-L LV, MV, and SV. 1. Prepare the Live Amplification Mix for the number of emulsion reactions being made, according to Table 1 for Rapid libraries. Add the reagents in the order they are listed in the table. 2. Vortex the Live Amplification Mix for 5 seconds, and store on ice. Reagent Volume (μl) 1 LV Emulsion 2 LV Emulsions Mol. Bio. Grade Water empcr Additive x Amplification Mix Amplification Primer empcr Enzyme Mix PPiase 5 10 Total: Table 1: Preparation of the Live Amplification Mix for Rapid libraries from the GS FLX+ Series XL+ 3.2 DNA Library Capture 1. Prepare 1x Capture Bead Wash Buffer TW by mixing 1 ml of 10x Capture Bead Wash Buffer TW with 9 ml of Molecular Biology Grade Water. GS FLX+ Series XL+ 4 / 12 May 2011

5 2. Vortex the tubes of DNA Capture Beads. 3. Pellet the beads in a bench top minifuge, by spinning for 10 seconds, rotating the tube 180, and spinning again for 10 seconds. 4. Carefully remove and discard the supernatant without disturbing the bead pellet. 5. Wash each tube of beads twice with 1 ml of 1x Capture Bead Wash Buffer TW. Vortex to resuspend the beads, spin, and discard the supernatant after each wash. 6. Thaw an aliquot of the diluted DNA library to be amplified. If necessary, prepare a dilution of the library such that the volume to be added will be between 1 µl and 100 µl. Heat denature DNA prepared with the Rapid library method, by running the following program on a thermocycler, with the heated lid on: 95 C for 2 minutes 4 C on hold 7. To each tube of washed DNA Capture Beads, add the correct volume of the DNA library that will provide optimal amplification (e.g. per titration) to the bead pellet. Use the following equation: μl of library per tube = 6 desired molecule per bead x 35 x 10 beads per tube library concentration (in molecules / μl) 8. Vortex the tubes for 5 seconds to mix their contents. 9. Prepare the DNA Capture Beads with library DNA mixes for individual emulsion reactions. a. Transfer the captured library mixes from their DNA Capture Beads tubes to individual 15 ml tubes. Do not discard the original DNA Capture Beads tubes. b. Add 3.75 ml of the Live Amplification Mix to each 15 ml tube. c. From there, pipet 1 ml of the mix to the original DNA Capture Beads tubes that contained the captured library, vortex and transfer back the solution into the 15 ml tubes. d. Repeat two times. e. Vortex. 3.3 Emulsification 1. Pour the content from each 15 ml tube of captured library from Section 3.2 into a prepared emulsion cup (from Section 3.1.3). 2. Invert the cups 3 times to mix. 3. Shake in the TissueLyser at 12 Hz for 5 minutes. 3.4 Amplification Dispensing the Emulsions 1. After emulsification, dispense the empcr amplification mixes into 96-well thermocycler plates, at 100 µl per well; each cup of emulsion will fill approximately 180 wells. Emulsion in cup lids: Some emulsion may have lodged in the cup lids. You can pipet it up from the lids but DO NOT spin the emulsion cups in an attempt to reclaim this material as this would risk breaking the emulsions. Air bubbles: dislodge any air bubbles that may be present at the bottom of the wells by gently tapping the plate. 2. Cap the wells and make sure that all the wells are properly sealed. 3. Clean up the area of any spilled reaction mix Amplification Reaction 1. Bring the plates containing the emulsified amplification reactions to the postamplification area, place them in a thermocycler, and start the amplification program with the heated lid on. The program takes ~8-9 h to complete. 1x 4 minutes at 94 C 50x 30 seconds at 94 C, 10 minutes at 60 C 10 C on hold Do not freeze the DNA beads: You can leave the amplified reactions at 10 C for up to 16 hours before further processing the samples. Emulsion breakage: Check all wells for emulsion breakage (i.e. faint yet distinct layers with a clearer middle or bottom layer). If the emulsion in any well appears broken, discard the entire well and do not recover the beads from it. See Section 4.2 for pictures of intact and broken emulsions. GS FLX+ Series XL+ 5 / 12 May 2011

6 3.5 Bead Recovery Vacuum-Assisted Emulsion Breaking Set Up 1. Retrieve the Enhancing Fluid XT and the Annealing Buffer XT, and keep at room temperature. 2. Obtain a GS FLX Titanium empcr Breaking Kit, LV/MV, 12 pcs. See Figure 3 for a general view of an assembled set up. 3. Attach a 50 ml conical tube to each of the two lids of the empcr breaking Kit LV/MV. Save the caps. 4. Insert the blue connector into the top opening of the 8-pronged transpette. 5. Connect the other end of the tubing to a vacuum source (with liquid trap to capture the isopropanol waste). If a vacuum source is not available, aspirate the emulsions from the microtiter plate wells with a syringe and blunt needle, as described for the SVE procedure, in the GS FLX+ Series XL+, empcr Amplification Method Manual Lib-L SV. Figure 3: Schematic view of an assembled set up for vacuum-assisted emulsion breaking and bead recovery for Large Volume Emulsions Emulsion Collection and Initial Washes 1. Aspirate the emulsions from each emulsion cup, 8 wells at a time and collect them in the two 50 ml collection tubes, using a slow circular motion of the transpette tips at the bottom of the wells. After aspirating all the emulsions, turn the transpette upside-down to help drain as much material as possible into the collection tubes. 2. Rinse the plates twice with 100 μl of isopropanol per well. Aspirate the rinse and turn the transpette upside-down to retrieve as much material as possible. GS FLX+ Series XL+ 6 / 12 May 2011

7 3. If you are processing more than one emulsion cup of the same library sample: a. Turn off the vacuum. b. Remove and cap the two 50 ml tubes containing the amplified DNA beads from the first emulsion cup (use the caps set aside). c. Attach two new 50 ml collection tubes to the lids of the breaking set up. Save the caps. d. Repeat Steps 1 and SLOWLY aspirate an additional (approximate) 5 ml of isopropanol to collect any beads that may remain in the tubing. 5. Turn off the vacuum, and remove and cap the two 50 ml collection tubes containing the amplified DNA beads. 6. If you are processing more than one library sample, repeat this section for each sample, using a new Emulsion Breaking assembly for each sample (see Figure 3) Bead Washes and Recovery Tube requirement: All 1.7 ml tubes must be siliconized. Be careful not to disturb the pellet during the washes while discarding the supernatant. 11. Centrifuge and discard the supernatant as in Step Add 35 ml of Enhancing Fluid XT and vortex well. 13. Centrifuge and discard the supernatant as in Step 3, leaving approximately 2 ml of Enhancing Fluid XT. 14. Transfer the DNA bead suspension using a 1000 µl pipette in two 1.7 ml tubes for each emulsion cup processed (a total of 4 tubes per full LV kit). 15. Spin-rotate-spin and discard the supernatant. 16. Repeat Steps 14 and 15 until the entire DNA bead suspension has been transferred. 17. Rinse each of the 50 ml collection tubes with 600 μl of Enhancing Fluid XT, vortex, and add this rinse to the 1.7 ml tubes. Spin-rotate-spin and discard the supernatant. 18. Thoroughly rinse each bead pellet twice with 1 ml of Enhancing Fluid XT. Spinrotate-spin and discard the supernatant 19. Add 1 ml of Enhancing Fluid XT to each bead pellet and vortex. 3.6 DNA Library Bead Enrichment At this point, you will have two 1.7 ml tubes for each emulsion cup processed. The reagent volumes listed in this section apply to each tube of beads. 1. Vortex each tube and mix the 50 ml collection tubes in pairs by transferring their contents back and forth, until the bead suspensions are of equivalent amount of emulsion oil. 2. Add isopropanol to a final volume of 40 ml in each collection tube and vortex. 3. Pellet the beads in a centrifuge at 930 x g for 5 min (2000 rpm in a Beckman Allegra centrifuge, rotor SX4750) and carefully remove the supernatant. 4. Add 35 ml of Enhancing Fluid XT and vortex well to resuspend (use glass rod, if necessary). 5. Centrifuge and discard the supernatant as in Step Add 35 ml of isopropanol and vortex well. 7. Centrifuge and discard the supernatant as in Step Add 35 ml of isopropanol and vortex well. 9. Centrifuge and discard the supernatant as in Step Add 35 ml of ethanol and vortex well Preparation for Enrichment Hazardous Chemical Sodium Hydroxide Solution: Sodium hydroxide (present in the Melt Solution) is a highly corrosive chemical that may cause burns if it contacts eyes or skin. Read the Material Safety Data Sheet for handling precautions. 1. Turn on the heating dry-block and set it to 65 C. 2. Prepare the Melt Solution by mixing 125 μl of NaOH (10 N) in ml of Molecular Biology Grade Water. 3. Spin-rotate-spin the tubes of beads and discard the supernatant. 4. Add 1 ml of Melt Solution per tube of beads and vortex. Incubate for 2 minutes at room temperature. Spin-rotate-spin and discard the supernatant. 5. Repeat Step 4 once. 6. Add 1 ml of Annealing Buffer XT per tube of beads and vortex. Spin-rotate-spin and discard the supernatant. GS FLX+ Series XL+ 7 / 12 May 2011

8 7. Repeat Step 6 once. 8. Optional: To determine the % breaking efficiency, do the following: a. Add 1 ml of Annealing Buffer XT and vortex. b. Count a 3 µl aliquot of the bead suspension from each tube and add the two values to calculate the total % bead recovery. A recovery of over 85% would be typical at this point of the procedure. Calculate the % bead recovery using following equation: Number of beads recovered % Bead Recovery = x x 10 c. Spin-rotate-spin and discard the supernatant. 9. Add 45 μl of Annealing Buffer XT per tube and 25 μl of Enrichment Primer per tube, and vortex. 10. Place the tubes in a heat block at 65 C for 5 minutes, and then promptly cool on ice for 2 minutes. 11. Add 800 μl of Enhancing Fluid XT per tube and vortex. Spin-rotate-spin and discard the supernatant. 12. Add 1 ml of Enhancing Fluid XT per tube and vortex. Spin-rotate-spin and discard the supernatant. 13. Repeat Step Add 800 μl of Enhancing Fluid XT per tube and vortex Preparation of the Enrichment Beads 1. Vortex the tube of brown Enrichment Beads for 1 minute to resuspend its contents completely. If you are processing half an LV empcr Kit (1 emulsion cup), aliquot 160 µl and store the rest at +2 to +8ºC. 2. Pellet the Enrichment Beads using a Magnetic Particle Concentrator (MPC). 3. Discard the supernatant, taking care not to draw off any Enrichment Beads. 4. Add 1 ml of Enhancing Fluid XT and vortex. 5. Pellet the Enrichment Beads using an MPC. 6. Discard the supernatant, taking care not to draw off any Enrichment Beads. 7. Repeat Steps 4 to After discarding the supernatant, remove the tube from the MPC. 9. Add 320 μl for 2 emulsion cups (or 160 μl for 1 emulsion cup) of Enhancing Fluid XT and vortex Enrichment of the DNA-Carrying Beads 1. Add 80 μl of washed Enrichment Beads to each tube of amplified DNA beads (from Section 3.6.1) and vortex. 2. Rotate the tubes on the rotator, at room temperature (+15 to +25ºC) for 5 minutes. 3. Place the tubes in the MPC, and wait 3-5 minutes to pellet the Enrichment Beads. 4. Invert the MPC several times. 5. Carefully discard the supernatant from each tube using a 1000 µl pipette, taking care not to draw off any brown Enrichment Beads. Optionally, collect the supernatants containing anti-enriched beads for troubleshooting. 6. Wash the beads with Enhancing Fluid XT until there are no visible beads remaining in the supernatants, as follows: a. Add 1 ml of Enhancing Fluid XT per tube. b. Remove the tubes from the MPC and vortex the tubes. c. Place the tubes back into the MPC to pellet the beads on the wall of the tube with the magnet. Invert the MPC. d. Carefully discard the supernatant from each tube with a 1000 µl pipette, taking care not to draw off any Enrichment Beads. e. Repeat 6 to 10 times until white DNA beads are no longer being aspirated. Optionally, collect the supernatants of each wash, and spin to monitor when washes are complete Collection of the Enriched DNA Beads 1. Remove the tubes of enriched beads (enrichment tubes) from the MPC and resuspend each bead pellet in 700 μl of Melt Solution. 2. Vortex for 5 seconds, and place the enrichment tubes in the MPC until the Enrichment Beads have pelleted. 3. Transfer the supernatants containing enriched DNA beads from each sample (> 1.4 ml) into a corresponding 1.7 ml collection tube (one sample per 1.7 ml tube). 4. Spin-rotate-spin the single 1.7 ml collection tube, and discard the supernatants. GS FLX+ Series XL+ 8 / 12 May 2011

9 5. Add once again 700 μl of Melt Solution to the enrichment tubes. 6. Vortex for 5 seconds, and place the enrichment tubes in the MPC until the Enrichment Beads have pelleted. 7. Transfer the supernatants containing enriched DNA beads into the same 1.7 ml collection tube. 8. Discard the enrichment tubes. 9. Spin-rotate-spin the 1.7 ml collection tube and discard the supernatants. 10. Add 1 ml of Annealing Buffer XT per collection tube and vortex for 5 seconds. 11. Spin-rotate-spin and discard the supernatant. 12. Repeat Steps 10 and 11 two more times. 13. Resuspend each bead pellet in 200 μl of Annealing Buffer XT. 3.7 Sequencing Primer Annealing 1. Add 50 μl of Sequencing Primer to each collection tube and vortex. 2. Place the collection tubes in a heat block at 65 C for 5 min, and then promptly on ice for 2 min. 3. Add 800 μl of Annealing Buffer XT per collection tube and vortex for 5 seconds. Spin-rotate-spin, and discard the supernatant. 4. Repeat Step 3 two times with 1 ml of Annealing Buffer XT. 5. Add 1 ml of Annealing Buffer XT to each bead pellet and vortex. 6. To determine the % bead enrichment, do the following: a. Count a 3 µl aliquot of the beads with a particle counter. b. Calculate the % bead enrichment using the following equation: Number of enriched beads recovered % Bead Recovery = 6 35 x 10 beads/cup x100 c. Percent enrichment values between 5 and 20% are indicative of libraries that usually yield good sequencing results. 7. Store the beads at +2 to +8 C and sequence them within two weeks. GS FLX+ Series XL+ 9 / 12 May 2011

10 4. APPENDIX 4.1 Bead Counter Settings 454 Life Sciences Corporation, a Roche company, recommends the use of the Innovatis CASY TTC, TT, and DT models, as well as the Coulter Counter Multisizer 3, Z2, and Z1 models from Beckman Coulter for the quantitation of amplified DNA library beads obtained from empcr amplification reactions. Table 2 shows the settings of the CASY models for bead counting. Figure 4 shows the settings of the Coulter Counter Multisizer 3 model and Table 3, the settings of the Coulter Counter Multisizer Z2 or Z1 model. Parameter Settings Dual Thresholds Upper Size (T u ) 25 µm Lower Size (T l ) 15 µm Count Mode Between Aperture 150 µm Metered Volume 1.2 ml (400 µl x 3) Figure 4: Coulter Counter Multisizer 3 settings for bead counting Result Type Dilution Factor* Concentration 3333 (10 ml diluent) Table 2: Innovatis CASY TTC, TT, and DT models settings for bead counting. * for 3 µl of beads GS FLX+ Series XL+ 10 / 12 May 2011

11 Parameter Dual Thresholds Settings Single Threshold 4.2 Pictures of Emulsions A B Upper Size (T u ) 25 µm -- Lower Size (T l ) 15 µm 15 µm Count Mode Between Above T l Aperture 100 µm 100 µm Metered Volume Result Type Concentration Concentration Dilution Factor* 3333 (10 ml diluent) 3333 C Table 3: Coulter Counter Z2 or Z1 models settings for bead counting. Dual thresholds are preferable, if available. * for 3 μl of beads Figure 5: A and B show intact emulsions appearing as an homogenous suspension (A), at times layered by a clearer phase (B). The multiple bands in C are a sign of a broken emulsion. GS FLX+ Series XL+ 11 / 12 May 2011

12 Table of Contents 1. WorkFlow Before You Begin Sample Handling Strategy for Large Volume Emulsions Determining the Amount of Library to Use in empcr Amplification Library Requirements Procedure Preparation of the Reagents and of the Emulsion Oil Preparation of the Reagents Preparation of the Emulsion Oil Preparation of the Mock Amplification Mix and Pre-Emulsions Preparation of the Live Amplification Mix DNA Library Capture Emulsification Amplification Dispensing the Emulsions Amplification Reaction Bead Recovery Vacuum-Assisted Emulsion Breaking Set Up Emulsion Collection and Initial Washes Bead Washes and Recovery DNA Library Bead Enrichment Preparation for Enrichment Preparation of the Enrichment Beads Enrichment of the DNA-Carrying Beads Collection of the Enriched DNA Beads Sequencing Primer Annealing Appendix Bead Counter Settings Pictures of Emulsions Published by 454 Life Sciences Corp. A Roche Company Branford. CT USA Life Sciences Corp. All rights reserved. For life science research only. Not for use in diagnostic procedures. 454, 454 LIFE SCIENCES, 454 SEQUENCING, GS FLX, GS FLX TITANIUM, GS JUNIOR, EMPCR, PICOTITERPLATE, PTP, NEWBLER, REM, GTYPE, AMPLITAQ, AMPLITAQ GOLD, FASTSTART, NIMBLEGEN, SEQCAP, CASY, and INNOVATIS, are trademarks of Roche. Other brands or product names are trademarks of their respective holders. License disclaimer information is subject to change or amendment. For current license information, please visit our web site at (1) 0511 GS FLX+ Series XL+ 12 / 12 May 2011

Procedure & Checklist - 10 kb Template Preparation and Sequencing

Procedure & Checklist - 10 kb Template Preparation and Sequencing Procedure & Checklist - 10 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure can be used to prepare 10 kb libraries

More information

Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries

Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries Procedure & Checklist - cdna Capture Using SeqCap EZ Libraries Before You Begin This document describes the process for capturing cdna prepared with the SMARTer PCR cdna Synthesis Kit (Clontech) and pulled-down

More information

Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing

Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Procedure & Checklist Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Before You Begin This document describes a procedure for multiplexing 5 Mb microbial genomes

More information

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit Introduction The Agencourt Genfind v2 Blood & Serum DNA Isolation Kit utilizes Agencourt s patented SPRI paramagnetic

More information

Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA)

Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA) Procedure & Checklist - 10 kb Template Preparation and Sequencing (with Low-Input DNA) Before You Begin To perform this procedure, you must have the PacBio : Template Prep Kit DNA/Polymerase Binding Kit

More information

NR601. VAHTS TM mrna-seq V2 Library Prep Kit for Illumina

NR601. VAHTS TM mrna-seq V2 Library Prep Kit for Illumina NR601 VAHTS TM mrna-seq V2 Library Prep Kit for Illumina v Vazyme Biotech Co., Ltd Website: www.vazyme.com Order: global@vazyme.com Support: support@vazyme.com Service: service@vazyme.com SYSTEMS www.vazyme.com

More information

GS FLX/Junior Titanium Technology

GS FLX/Junior Titanium Technology www.454.com GS FLX/Junior Titanium Technology GS FLX and GS Junior Process Steps Overview gdna 1. DNA Library Construction * 4h 2. empcr 3. Sequencing 8 h 10 h Data output DNA Library Preparation Prepare

More information

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085 INSTRUCTION MANUAL Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085 Highlights Tunable: Size selection can be tuned from 100 bp to 1000 bp with left, right, or double size selection

More information

Procedure & Checklist - 2 kb Template Preparation and Sequencing

Procedure & Checklist - 2 kb Template Preparation and Sequencing Procedure & Checklist - 2 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio DNA Template Prep Kit (verify you have the correct kit for your insert

More information

Sequencing Method Manual for the GS FLX+ Instrument

Sequencing Method Manual for the GS FLX+ Instrument Sequencing Method Manual for the GS FLX+ Instrument GS FLX+ Series XLR70 Kit May 2011 For life science research only. Not for use in diagnostic procedures. Instrument / Kit GS Junior / Junior GS FLX+ /

More information

JetSeq Clean. Product Manual

JetSeq Clean. Product Manual JetSeq Clean Product Manual 2 Product Manual bioline.com/jetseq JetSeq Clean JetSeq Clean TABLE OF CONTENTS 1 Kit contents 04 2 Description 05 3 Equipment and reagents to be supplied by user 06 4 Storage

More information

SOLiD EZ Bead Emulsifier

SOLiD EZ Bead Emulsifier QUICK REFERENCE SOLiD EZ Bead Emulsifier Pub. Part no. 4441487 Rev. E Rev. Date October 2011 Note: For safety guidelines, refer to the Safety section in the Applied Biosystems SOLiD EZ Bead Emulsifier

More information

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit Blood & Serum Genomic DNA Isolation Kit Page 1 of 9 Please refer to http://www.agencourt.com/technical for updated protocols and refer to MSDS instructions when handling or shipping any chemical hazards.

More information

Target Sequence Capture Using Roche NimbleGen SeqCap EZ Library

Target Sequence Capture Using Roche NimbleGen SeqCap EZ Library Please note: the shared protocols described herein may not have been validated by Pacific Biosciences and are provided as-is and without any warranty. Use of these protocols is offered to those customers

More information

10 kb to 20 kb Template Preparation and Sequencing with Low-Input DNA

10 kb to 20 kb Template Preparation and Sequencing with Low-Input DNA Please note: the shared protocols described herein may not have been validated by Pacific Biosciences and are provided as-is and without any warranty. Use of these protocols is offered to those customers

More information

Procedure & Checklist - 1 kb Template Preparation and Sequencing

Procedure & Checklist - 1 kb Template Preparation and Sequencing Procedure & Checklist - 1 kb Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. Fragment and Concentrate DNA Important: The distribution

More information

Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System

Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Procedure and Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit and have reviewed the

More information

Procedure & Checklist bp Template Preparation and Sequencing

Procedure & Checklist bp Template Preparation and Sequencing Procedure & Checklist - 500 bp Template Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure is optimized for SMRTbell template

More information

VAHTS Stranded mrna-seq Library Prep Kit for Illumina

VAHTS Stranded mrna-seq Library Prep Kit for Illumina Instruction Manual VAHTS Stranded mrna-seq Library Prep Kit for Illumina Vazyme Cat #NR602 Vazyme Biotech Co., Ltd Web: www.vazyme.com Tel: 400-600-9335 Sales: Sales@vazyme.com Support: Support@ vazyme.com

More information

Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems

Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems Procedure & Checklist >20 kb Template Preparation Using BluePippin Size-Selection System (15-20 kb Cutoff) for Sequel Systems Before You Begin To perform this procedure, you must have the PacBio Template

More information

Procedure & Checklist bp Amplicon Library Preparation and Sequencing

Procedure & Checklist bp Amplicon Library Preparation and Sequencing Procedure & Checklist - 250 bp Amplicon Library Preparation and Sequencing Before You Begin To perform this procedure, you must have the PacBio Template Prep Kit. This procedure is optimized for SMRTbell

More information

MEDIP-SEQUENCING PROTOCOL

MEDIP-SEQUENCING PROTOCOL MEDIP-SEQUENCING PROTOCOL MAGMEDIP KIT Cat. No. C02010020 Table 1 The GenDNA module provides you with an excess of buffer for the preparation of DNA. Sufficient buffer is given for the preparation of several

More information

Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System

Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Procedure & Checklist - 20 kb Template Preparation Using BluePippin Size-Selection System Before You Begin To perform this procedure, you must have the PacBio DNA Template Prep Kit 2.0 (3 kb to 10 kb)

More information

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Adapters for Multiplex SMRT Sequencing Before You Begin This document describes methods for generating SMRTbell libraries using

More information

Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems

Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems Before You Begin The long read lengths of the PacBio System are well-suited for characterizing full-length transcripts produced from

More information

Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads

Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads Procedure & Checklist - Greater Than 10 kb Template Preparation Using AMPure PB Beads Before You Begin This procedure can be used to prepare greater than 10 kb libraries from 5 μg of sheared and concentrated

More information

Sequencing Method Manual

Sequencing Method Manual Sequencing Method Manual Instrument GS Junior GS FLX+ GS FLX+ GS FLX Kit Junior XL+ XLR70 XLR70 For life science research only. Not for use in diagnostic procedures. 1 WORKFLOW GS FLX + Instrument Operation

More information

Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes

Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes Procedure & Checklist cdna Capture Using IDT xgen Lockdown Probes Before You Begin This document describes the process for capturing cdna prepared with the SMARTer PCR cdna Synthesis Kit (Clontech) and

More information

MinION PROTOCOL. Adapted from Janneke Wit by Robyn Tanny May Company Kit/Item Catalog Number

MinION PROTOCOL. Adapted from Janneke Wit by Robyn Tanny May Company Kit/Item Catalog Number MinION PROTOCOL Adapted from Janneke Wit by Robyn Tanny May 2016 Company Kit/Item Catalog Number Fisher Eppendorf DNA/RNA LoBind Tubes 13-698-791 Fisher Covaris g-tube NC0380758 NEB NEBNext FFPE Repair

More information

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol

BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol BoTest Matrix E Botulinum Neurotoxin Detection Kit Protocol 505 S. Rosa Road, Suite 105 Madison, WI 53719 1-608-441-8174 info@biosentinelpharma.com BioSentinel Part No: L1016, Release Date: May 29, 2014

More information

USER GUIDE For Illumina Platform

USER GUIDE For Illumina Platform USER GUIDE For Illumina Platform Copyright Nimagen B.V. P.O. Box 91 6500 AB Nijmegen The Netherlands Tel. +31 (0)24 820 0241 Fax. +31 (0)24 358 0259 info@nimagen.com VAT#: NL850011243B01 Rabobank Nijmegen:

More information

Procedure & Checklist Multiplex Genomic DNA Target Capture Using IDT xgen Lockdown Probes

Procedure & Checklist Multiplex Genomic DNA Target Capture Using IDT xgen Lockdown Probes Procedure & Checklist Multiplex Genomic DNA Target Capture Using IDT xgen Lockdown Probes Before You Begin This procedure describes capture and enrichment of regions of interest by using IDT xgen Lockdown

More information

Mag-Bind cfdna Kit. M preps M preps M Preps

Mag-Bind cfdna Kit. M preps M preps M Preps Mag-Bind cfdna Kit M3298-00 5 preps M3298-01 50 preps M3298-02 200 Preps March 2018 Mag-Bind cfdna Kit Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Preparing Reagents...4

More information

AGENCOURT ORAPURE Buccal Cell DNA Isolation Kit

AGENCOURT ORAPURE Buccal Cell DNA Isolation Kit Buccal Cell DNA Isolation Kit Page 1 of 12 Please refer to http://www.agencourt.com/technical for updated protocols and refer to MSDS instructions when handling or shipping any chemical hazards. AGENCOURT

More information

Microwell-Seq. High-throughput Single Cell RNA-Seq Kit. Protocol. Index

Microwell-Seq. High-throughput Single Cell RNA-Seq Kit. Protocol. Index Microwell-Seq High-throughput Single Cell RNA-Seq Kit Protocol Index 1 Introduction 2 Kit Reagent 3 Store 4 Application 5 Prepared materials 6 Note 7 Preparation 8 Workflow 1 1 Introduction Microwell-Seq

More information

mi-mag mrna Isolation Kit

mi-mag mrna Isolation Kit mi-mag mrna Isolation Kit Cat. No [50 Reactions] This kit is for research purposes only. Not for use in diagnostic procedures. For in vitro use only. Introduction This kit contains enough materials for

More information

illumina TruSeq RNA Sample Prep. (LT) Protocol 1

illumina TruSeq RNA Sample Prep. (LT) Protocol 1 illumina TruSeq RNA Sample Prep. (LT) Protocol 1 Performed using the TruSeq RNA Sample Preparation Kit (A cat#fc-122-1001, B cat#fc122-1002) Purify and Fragment mrna NOTE: Use 3ug of Total RNA to initiate

More information

Applied Biosystems SOLiD 4 System Templated Bead Preparation Guide

Applied Biosystems SOLiD 4 System Templated Bead Preparation Guide Applied Biosystems SOLiD 4 System Templated Bead Preparation Guide March 2010 Library Preparation Templated Bead Preparation Instrument Operation For Research Use Only. Not intended for any animal or human

More information

Additional reagents and materials that are not supplied

Additional reagents and materials that are not supplied sparq PureMag Beads Cat. No. 95196-005 Size: 5 ml Store at 2 C to 8 C 95196-060 60 ml 95196-450 450 ml Description sparq PureMag Beads uses reversible nucleic acid-binding properties of magnetic beads

More information

Illumina TruSeq Stranded mrna (LT) Protocol 1

Illumina TruSeq Stranded mrna (LT) Protocol 1 Illumina TruSeq Stranded mrna (LT) Protocol 1 Performed using the TruSeq Stranded mrna Sample Preparation Kit (A cat#fc-122-2101, B cat#fc122-2102) Purify and Fragment mrna NOTE: Use 500ng of Total RNA

More information

ChIP Protocol for fresh or frozen cross linked cells

ChIP Protocol for fresh or frozen cross linked cells Prior to starting your ChIPs and Shearing Turn on sonifiers and cooling system allow system to reach -2 C before shearing Cool bench top centrifuge to 4 C Prepare all of your buffers with protease inhibitors

More information

DNA Size Selection Magnetic Beads

DNA Size Selection Magnetic Beads DNA Size Selection Magnetic Beads Catalog #: 801-117 User Manual Last revised July 30 th, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

JetSeq DNA Library Preparation Kit. Product Manual

JetSeq DNA Library Preparation Kit. Product Manual JetSeq DNA Library Preparation Kit Product Manual 2 JetSeq DNA Library Preparation Kit JetSeq DNA Library Preparation Kit TABLE OF CONTENTS 1 Kit contents 04 2 Description 05 3 Storage 06 4 Safety information

More information

NEBNext DNA Library Prep Master Mix Set for Illumina

NEBNext DNA Library Prep Master Mix Set for Illumina LIBRARY PREPARATION NEBNext DNA Library Prep Master Mix Set for Illumina Instruction Manual NEB #E6040S/L 12/60 reactions Version 8.0 9/18 be INSPIRED drive DISCOVERY stay GENUINE This product is intended

More information

NGS clean-up and size selection

NGS clean-up and size selection NGS clean-up and size selection User manual NucleoMag NGS Clean-up and Size Select May 2014 / Rev. 01 NGS clean-up and size selection Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Equipment and

More information

Formaldehyde Cross-linking of Chromatin from Drosophila

Formaldehyde Cross-linking of Chromatin from Drosophila 2 Formaldehyde Cross-linking of Chromatin from Drosophila Protocol from modencode IGSB University of Chicago originally written by Alex Crofts and Sasha Ostapenko and updated by Matt Kirkey. 1. Set centrifuge

More information

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field.

We want to thank and acknowledge the authors for sharing this protocol and their contributions to the field. We adopted the protocol described in the Extended Experimental Procedures section I.a.1 of the 2014 Cell paper by Rao and Huntley et. al: A 3D Map of the Human Genome at Kilobase Resolution Reveals Principles

More information

Stranded mrna-seq Lib Prep Kit for Illumina

Stranded mrna-seq Lib Prep Kit for Illumina Stranded mrna-seq Lib Prep Kit for Illumina RK20301 (10ng-1ug Input Total RNA) (Illumina Compatible) C U G A www.abclonal.com version: N12G13v1.0 Contents 1.Introduction 01 2.Components 02 3.Additional

More information

chemagic mrna Direct Kit

chemagic mrna Direct Kit chemagic mrna Direct Kit for general purposes Kit for the direct isolation of mrna from animal and plant tissue and cells. Kit Components M-PVA OdT Magnetic Beads Suspension Buffer 1 Lysis Buffer 2 Wash

More information

Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems

Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems Procedure & Checklist - Iso-Seq Template Preparation for Sequel Systems Before You Begin The Sequel System generates long reads that are well-suited for characterizing full-length transcripts produced

More information

Procedure & Checklist - Preparing >15 kb Libraries Using SMRTbell Express Template Preparation Kit

Procedure & Checklist - Preparing >15 kb Libraries Using SMRTbell Express Template Preparation Kit Procedure & Checklist - Preparing >15 kb Libraries Using SMRTbell Express Template Preparation Kit This document provides recommendations for preparing >15 kb size-selected SMRTbell libraries from 3-5

More information

NxSeq UltraLow DNA Library Kit, 12 Reactions

NxSeq UltraLow DNA Library Kit, 12 Reactions NxSeq UltraLow DNA Library Kit, 12 Reactions Illumina-compatible FOR RESEARCH USE ONLY. NOT FOR HUMAN OR DIAGNOSTIC USE Lucigen Corporation 2905 Parmenter St, Middleton, WI 53562 USA Toll Free: (888) 575-9695

More information

PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract

PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract PARP1-Trap_A for Immunoprecipitation of PARP1- Fusion Proteins from cell extract Only for research applications, not for diagnostic or therapeutic use. Introduction Specificity Poly(ADP-ribose) polymerase

More information

Required Materials. Page 1 PN Version 06 (February 2018)

Required Materials. Page 1 PN Version 06 (February 2018) Procedure & Checklist - Preparing >30 kb SMRTbell Libraries Using Megaruptor Shearing and BluePippin Size-Selection for PacBio RS II and Sequel Systems This document provides recommendations for preparing

More information

mag maxi kit Intended use of the mag maxi kits

mag maxi kit Intended use of the mag maxi kits mag maxi kit For in vitro diagnostic use 40403 40430 10 288 May 2014 LGC Genomics GmbH Ostendstr. 25 TGS Haus 8 12459 Berlin Germany Tel: +49 (0)30 5304 2200 Fax: +49 (0)30 5304 2201 Intended use of the

More information

ISOFECAL for Beads Beating Manual (First edition)

ISOFECAL for Beads Beating Manual (First edition) Fecal DNA Extraction Kit ISOFECAL for Beads Beating Manual (First edition) Code No. 315-06281 NIPPON GENE CO., LTD. Table of contents I Product description 1 II Contents of kit 1 III Storage 2 IV Precautions

More information

GS FLX Titanium Sequencing Method Manual. October 2008

GS FLX Titanium Sequencing Method Manual. October 2008 GS FLX Titanium Sequencing Method Manual October 2008 798_Seq-MethMan_Titel-RS.indd 1 13.08.2008 12:07:28 Uhr Table of Contents Preface About this Manual...5 Safety...7 Assumptions...8 Sample ready...8

More information

xgen hybridization capture of DNA libraries

xgen hybridization capture of DNA libraries xgen hybridization capture of DNA libraries For NGS target enrichment Uses IDT s: xgen Hybridization and Wash Kit xgen Universal Blockers TS Mix, 10 bp TS Mix, or NXT Mix xgen Lockdown Panels and Probes

More information

Project: RADseqReady Plate # Library # Name: Date: Section 1: DNA Standardization

Project: RADseqReady Plate # Library # Name: Date: Section 1: DNA Standardization BestRAD Library Preparation Based on protocol of Ali et al. 2015 (10.1534/genetics.115.183665) Adapted by Linda Rutledge many times but this version was done on August 16, 2016 Section 1: DNA Standardization

More information

Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System

Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System Procedure & Checklist Preparing Multiplexed Microbial SMRTbell Libraries for the PacBio Sequel System Before You Begin This procedure is for preparing multiplexed SMRTbell libraries for sequencing on the

More information

CleanPlex UMI NGS Panel

CleanPlex UMI NGS Panel CleanPlex UMI NGS Panel User Guide This user guide is for the following products: CleanPlex UMI Lung Cancer Panel CleanPlex UMI Custom NGS Panel Get the latest user guide at: www.paragongenomics.com/product_documents/

More information

pluribead KIT Cell Separation Protocol M-Bead

pluribead KIT Cell Separation Protocol M-Bead pluribead KIT Cell Separation Protocol M-Bead pluriselect@hiss-dx.de 15 14 13 12 11 9 8 7 6 5 4 3 2 1 50 40 30 20 2 Contents Contents pluribead Kit Components & Additional Materials 2 Separation Protocol

More information

ChargeSwitch gdna Rendered Meat Purification Kit

ChargeSwitch gdna Rendered Meat Purification Kit USER GUIDE ChargeSwitch gdna Rendered Meat Purification Kit Purification of genomic DNA (gdna) from cattle feed, meal, and heparin products Catalog Number CS400-100 Publication Number MAN0000574 Revision

More information

AdnaTest EMT-1/StemCellSelect

AdnaTest EMT-1/StemCellSelect AdnaTest EMT-1/StemCellSelect Enrichment of tumor cells from blood for gene expression analysis For research use only Manual T-1-533 Contents Order Information... 3 Purpose... 3 Abbreviations and Symbols...

More information

AdnaTest OvarianCancer-2 Select

AdnaTest OvarianCancer-2 Select AdnaTest OvarianCancer-2 Select Enrichment of tumor cells from blood of ovarian cancer patients for gene expression analysis For research use only Manual T-1-538 Contents Order Information... 3 Purpose...

More information

EPIGENTEK. EpiQuik Circulating Cell-Free DNA Isolation Kit. Base Catalog # P-1064 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Circulating Cell-Free DNA Isolation Kit. Base Catalog # P-1064 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Circulating Cell-Free DNA Isolation Kit Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE Uses: The EpiQuik Circulating Cell-Free DNA Isolation Kit utilizes magnetic beads based sizefractionation

More information

Total RNA Isolation. User Manual. NucleoMag 96 RNA MACHEREY-NAGEL. January 2010 / Rev. 02

Total RNA Isolation. User Manual. NucleoMag 96 RNA MACHEREY-NAGEL. January 2010 / Rev. 02 Total RNA Isolation User Manual NucleoMag 96 RNA January 2010 / Rev. 02 MACHEREY-NAGEL Table of contents 1 Components 4 1.1 Kit contents 4 1.2 Material to be supplied by user 5 2 Product description 6

More information

Evaluation of Omega Mag-Bind TotalPure NGS Beads for DNA Size Selection

Evaluation of Omega Mag-Bind TotalPure NGS Beads for DNA Size Selection Evaluation of Omega Mag-Bind TotalPure NGS Beads for Size Selection By Maggie Weitzman, M.Sc. (University of Oregon / GC3F) Disclaimer: Neither Maggie Weitzman, the University of Oregon, nor the Genomics

More information

Swift Hybridization Capture Kits

Swift Hybridization Capture Kits Protocol Swift Hybridization Capture Kits For NGS Target Enrichment Uses: Swift Exome Hyb Panel, Cat. No. 83216 Swift Pan-Cancer Hyb Panel, Cat. No. 83316 Swift Inherited Diseases Hyb Panel, Cat. No. 83416

More information

Controller Training Kit User Guide

Controller Training Kit User Guide Library Construction Chromium Controller Training Kit User Guide FOR USE WITH Chromium Controller & Training Reagents, Gel Bead & Chip Kits PN-120245 NOTICES Notices Manual Part Number CG00021 Rev A Legal

More information

FastTrack MAG mrna Isolation Kits

FastTrack MAG mrna Isolation Kits USER GUIDE FastTrack MAG mrna Isolation Kits For isolating high-quality mrna from total RNA, cells, and tissue Catalog Numbers K1580-01 and K1580-02 Document Part Number 25-0754 Publication Number MAN0000475

More information

30 Plex Human Luminex (Invitrogen Kit, Single Plate)

30 Plex Human Luminex (Invitrogen Kit, Single Plate) 30 Plex Human Luminex (Invitrogen Kit, Single Plate) 1. Defrost samples and bring to room temperature. 2. Bring Kit components to room temperature: Wash solution 20x. Assay Diluent. Incubation buffer.

More information

ChargeSwitch gdna Blood Kits

ChargeSwitch gdna Blood Kits Instruction Manual ChargeSwitch gdna Blood Kits For purification of genomic DNA from small volumes of human blood Catalog nos. CS11000, CS11010, and CS11010-10 Version A 6 January 2005 25-0814 ii Table

More information

BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012

BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012 BIOL110L-Cell Biology Lab Spring Quarter 2012 Module 3-4 Wednesday May 30, 2012 PART I: Isolation of over-expressed GFP-Karyopherins from yeast extracts by affinity capture on nucleoporins Summary: The

More information

User Guide. rrna Depletion Kit V1.2

User Guide. rrna Depletion Kit V1.2 rrna Depletion Kit V1.2 User Guide Catalog Number: 037 (RiboCop rrna Depletion Kit V1.2 (Human/Mouse/Rat)) 042 (SENSE Total RNA-Seq Library Prep Kit for Illumina with RiboCop) 037UG073V0201 FOR RESEARCH

More information

RayBio mrna Magnetic Beads Kit

RayBio mrna Magnetic Beads Kit RayBio mrna Magnetic Beads Kit Catalog #: 801-116 User Manual Last revised March 9 th, 2017 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite 100 Norcross,

More information

Ampli1 LowPass Kit. USER MANUAL Version 3.0. Low-pass WGS library prep kit for IonTorrent platforms. Content version: July 2017

Ampli1 LowPass Kit. USER MANUAL Version 3.0. Low-pass WGS library prep kit for IonTorrent platforms. Content version: July 2017 For research use only. Not for use in diagnostic procedures. For in vitro use only. Ampli1 LowPass Kit Low-pass WGS library prep kit for IonTorrent platforms USER MANUAL Version 3.0 Content version: July

More information

Alon s SCN ChIP Protocol

Alon s SCN ChIP Protocol Prior to starting your ChIPs and Shearing 1. Turn on sonifiers and cooling system allow system to reach -1 C before shearing 2. Cool bench top centrifuge to 4 C 3. Prepare all of your buffers with protease

More information

Ampli1 LowPass Kit. USER MANUAL Version 2.0. Low-pass WGS library prep kit for IonTorrent platforms. Content version: January 2017

Ampli1 LowPass Kit. USER MANUAL Version 2.0. Low-pass WGS library prep kit for IonTorrent platforms. Content version: January 2017 For research use only. Not for use in diagnostic procedures. For in vitro use only. Ampli1 LowPass Kit Low-pass WGS library prep kit for IonTorrent platforms USER MANUAL Version 2.0 Content version: January

More information

ChargeSwitch NoSpin Plasmid Kits

ChargeSwitch NoSpin Plasmid Kits USER GUIDE ChargeSwitch NoSpin Plasmid Kits For purification of plasmid DNA from bacterial cells using the MagnaClear Technology Catalog nos. CS10200, CS10201, CS10201-10 Version A 5 January 2005 25-0813

More information

DNA/RNA Extraction Kit

DNA/RNA Extraction Kit Kit Primerdesign Ltd genesig Easy DNA/RNA Extraction Kit 50 extractions Universal kit for isolation of RNA / DNA from food, water, clinical, veterinary and other samples types. DNA Testing For general

More information

Ribo-Zero Magnetic Kits*

Ribo-Zero Magnetic Kits* * Ribo-Zero Kit Catalog Number 6-Reactions Catalog Number 24-Reactions Ribo-Zero Magnetic Gold Kit (Human/Mouse/Rat) MRZG126 MRZG12324 Ribo-Zero Magnetic Kit (Human/Mouse/Rat) MRZH116 MRZH11124 Ribo-Zero

More information

User Guide. rrna Depletion Kit

User Guide. rrna Depletion Kit rrna Depletion Kit User Guide Catalog Number: 037.24 (RiboCop rrna Depletion Kit (Human/Mouse/Rat), 24 preps) 037.96 (RiboCop rrna Depletion Kit (Human/Mouse/Rat), 96 preps) 042.08 (SENSE Total RNA-Seq

More information

TrueBlot Protein G Magnetic Beads PG ml. TrueBlot Protein G Magnetic Beads PG ml. Bead Mean Diameter 0.5 µm. Bead Concentration

TrueBlot Protein G Magnetic Beads PG ml. TrueBlot Protein G Magnetic Beads PG ml. Bead Mean Diameter 0.5 µm. Bead Concentration Rockland s TrueBlot Protein G Magnetic Beads are uniform, non-aggregating, super-paramagnetic beads coupled with a biomolecule, such as Protein G. These beads are specifically designed, tested and quality

More information

Solutions for purifying nucleic acids by solidphase reversible immobilization (SPRI)

Solutions for purifying nucleic acids by solidphase reversible immobilization (SPRI) Solutions for purifying nucleic acids by solidphase reversible immobilization (SPRI) Philippe Jolivet and Joseph W. Foley Ludmer Centre for Neuroinformatics and Mental Health October 21, 2015 Based on

More information

High Capacity Magne Streptavidin Beads

High Capacity Magne Streptavidin Beads TECHNICAL MANUAL High Capacity Magne Streptavidin Beads Instruc ons for Use of Product V7820 Revised 7/16 TM474 High Capacity Magne Streptavidin Beads All technical literature is available at: www.promega.com/protocols/

More information

USER GUIDE. Ovation PART NO. 0344, 0344NB. Ultralow System V2

USER GUIDE. Ovation PART NO. 0344, 0344NB. Ultralow System V2 USER GUIDE Ovation PART NO. 0344, 0344NB Ultralow System V2 Patents, Licensing and Trademarks 2014 2017 NuGEN Technologies, Inc. All rights reserved. The Encore, Ovation and Applause families of products

More information

LOABeads MagSep 15/50 LOABeads MagSep 500

LOABeads MagSep 15/50 LOABeads MagSep 500 LOABeads MagSep 15/50 LOABeads MagSep 500 Product Manual Lab on a Bead AB Edition 2016-05-09 Copyright 2015-2016 Lab on a Bead AB Table of Contents 1. 2. 3. 4. 5. 6. Safety instructions...3 General handling

More information

LOABeads AffiAmino. Product Manual. Lab on a Bead AB. Revision date Copyright Lab on a Bead AB All rights reserved

LOABeads AffiAmino. Product Manual. Lab on a Bead AB. Revision date Copyright Lab on a Bead AB All rights reserved LOABeads AffiAmino Product Manual Lab on a Bead AB Revision date 2016-11-23 Copyright 2015-2016 Lab on a Bead AB All rights reserved Table of Contents 1. General information...3 2. Product data...4 3.

More information

Direct Polysome IP from Brain Tissue Myriam Heiman:

Direct Polysome IP from Brain Tissue Myriam Heiman: Direct Polysome IP from Brain Tissue Myriam Heiman: bonillm@rockefeller.edu Protocol below is for 1 IP, scale accordingly General Notes: -7 mouse striata pooled per IP -IP with 50 µg 19C8 and 50 µg 19F7

More information

M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079

M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079 M-Beads Magnetic silica beads DNA 3.0 (COOH) Order #: PR-MAG00078 & PR-MAG00079 MoBiTec GmbH 2015 Page 2 Contents Intended Use... 3 Principle... 3 Silica & Carboxylated M-Beads Magnetic silica beads DNA

More information

Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads. Product Numbers: RPNQ0096

Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads. Product Numbers: RPNQ0096 TECHNICAL DATA SHEET SPA Beads Caution: For Laboratory Use. A product for research purposes only. YSi (2 5 μm) Copper His-Tag SPA Beads Product Numbers: RPNQ0096 WARNING For research use only. Not recommended

More information

RayBio anti-mouse IgG Magnetic Beads

RayBio anti-mouse IgG Magnetic Beads RayBio anti-mouse IgG Magnetic Beads Catalog #: 801-103 User Manual Last revised January 4 th, 2017 Caution: Extraordinarily useful information enclosed ISO 1348 Certified 3607 Parkway Lane, Suite 100

More information

Drop-seq Protocol, 2015 v. 1.0 (5/21/15)

Drop-seq Protocol, 2015 v. 1.0 (5/21/15) page 1 Drop-seq Protocol, 2015 v. 1.0 (5/21/15) Evan Macosko & Melissa Goldman Before you begin: The following is the most up-to-date protocol for Drop-seq, including all equipment and reagents used. Please

More information

Technical Manual No. TM0261 Version

Technical Manual No. TM0261 Version Donkey Anti-Goat IgG MagBeads Cat. No. L00332 Technical Manual No. TM0261 Version 06272010 Index 1. Product Description 2. Instruction For Use 3. Troubleshooting 4. General Information 1. Product Description

More information

UPHO. ULTIMATE SAMPLE HOMOGENIZER cell disruption - user guide

UPHO. ULTIMATE SAMPLE HOMOGENIZER cell disruption - user guide UPHO ULTIMATE SAMPLE HOMOGENIZER cell disruption - user guide Cell disruption is an essential step in the workflow to extract and purify important biomolecules, such as nucleic acids and proteins. When

More information

LOABeads Protein A. Product no Product Manual. Lab on a Bead AB

LOABeads Protein A. Product no Product Manual. Lab on a Bead AB Product no 1001 LOABeads Protein A Product Manual Lab on a Bead AB Revision date 2016-03-08 Copyright 2015-2016 Lab on a Bead AB All rights reserved Table of Contents 1. General information 3 2. Antibody

More information

3 MATERIALS 4 3D PRINTING

3 MATERIALS 4 3D PRINTING 1 TABLE OF CONTENT 2 Introduction... 3 3 Materials... 4 4 3D printing... 4 5 Mixing of PDMS... 5 6 Degassing... 5 7 Baking... 6 8 Taking out the chip and making the holes... 6 9 Assembly & cleaning...

More information

AffiAmino UltraRapid Agarose

AffiAmino UltraRapid Agarose Product no 1003 AffiAmino UltraRapid Agarose Product Information Lab on a Bead AB Edition 20151030 All rights reserved Copyright 2015 Lab on a Bead AB Table of Contents 1. General information... 3 2. Principle

More information

Amine Magnetic Beads

Amine Magnetic Beads 588PR-02 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Amine Magnetic Beads (Cat. # 786-906, 786-907) think proteins! think G-Biosciences

More information