CrossLab Autosampler Syringes
|
|
- Rachel Newton
- 5 years ago
- Views:
Transcription
1 CrossLab Product Introductions CrossLab Autosampler Syringes With a broad selection of syringes for auto injection, CrossLab autosampler syringes provide what you need for accurate and effective sampling. CrossLab syringes meet all fit, form, and function criteria for specific autosampler models. Agilent delivers more value in every autosampler syringe: Lot number printed directly on the barrel with a corresponding Certificate of Conformance Illuminating backing strip, for effortless viewing of the volume scale Environmentally friendly packaging and improved design that reduces waste Individually packaged for contaminant-free use right out of the box Tips & Tools Replace syringe if dirt is noticeable, syringe cannot be cleaned or plunger doesn't slide easily. Replace needle if septa wear is abnormal or needle is clogged. Typical Needle Gauge Dimensions OD ID Gauge mm inches mm inches
2 CrossLab Product Introductions Needle Gauge 23 (0.64 mm) Single Gauge 23 (0.64 mm) Packed column injector ports Split/splitless injector ports 26 (0.47 mm) Single Gauge 26 (0.47 mm) Packed column injector ports Split/splitless injector ports Needle Termination Needle terminations are available in fixed or removable, with various tip styles. Fixed (cemented) Tips & Tools Follow manufacturer's recommendation for syringe cleaning and regularly inspect syringe barrel for sample build-up and needle tip for wear. Economical, reproducible injections for autosamplers Preferred for applications requiring trace level samples Recommended for use where probability of needle bending is minimal Can be heated up to 70 C Removable needle Versatile option for injections Needle can be replaced if damaged or clogged Allows needle to be changed for different applications Can be heated up to 120 C 8 Agilent CrossLab Selection Guide
3 CrossLab Supplies for Bruker, Varian* GC Systems Description Unit Column nut, brass, 1177, 1079, 1061, or 1041 injector 2/pk Column nut, stainless steel, 1093 injector 2/pk CP Varian* CP8400, CP8410, CP9010, CP9050 Varian* 8035, 8100, 8200 Description Needle Gauge/Length (mm)/tip Syringe Needle 10 Fixed needle 23/50/cone tip SG Fixed needle 26/50/bevel tip Removable needle 26/50/cone tip SG , 2/pk Fixed needle, 26/53/single hole tip /53/single hole tip , 2/pk (µl) Removable needle, *Formerly Varian GC systems, now Bruker products The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page
4 CrossLab Supplies for CTC Analytics GC Autosamplers CrossLab CTC Autosampler Syringes Agilent's CrossLab portfolio includes a variety of syringes compatible with CTC Analytics GC PAL and CombiPAL systems. Syringe capacities from 0.5 µl to 2.5 ml Fixed and removable needles Several needle tip styles to suit your application requirements High temperature syringes for headspace application with temperatures up to 150 C PTFE plunger seal option for smooth, leak-free operation Syringe specifications are matched to CTC holders to ensure proper fit and reliable functioning Autosampler Syringes for CTC CombiPAL and GC PAL, 1/pk (µl) Description Needle Gauge/Length (mm)/tip Syringe or Needle 0.5 -in-needle 23/50/cone tip * 5 Fixed needle 23/50/cone tip Fixed needle 26/50/cone tip Fixed needle 23/50/cone tip Fixed needle 25/50/cone tip Fixed needle 26/50/cone tip Fixed needle, 26/50/cone tip ** Fixed needle 26/50/bevel tip Fixed needle 26/50/cone tip Fixed needle, 23/50/cone tip Removable needle, 23/50/side hole tip *** Fixed needle 26/50/cone tip Fixed needle, 26/50/cone tip (ml) Description Needle Gauge/Length (mm)/tip Syringe 1 Fixed needle,, headspace 23/56/side hole tip Fixed needle,, headspace 23/56/side hole tip *Needle and plunger repair kit ** plunger *** needle 41
5 CrossLab Supplies for PerkinElmer GC Systems Vespel Capillary Column Ferrules Fitting Size (in.) Ferrule ID (mm) Column ID (mm) Hole Unit 1/ mm ID 1 10/pk or smaller 1/ /pk / /pk / /pk Vespel Packed Column Ferrules Fitting Size (in.) Ferrule ID (in.) Column OD (in.) Hole Unit 1/4 1/4 1/4 1 10/pk N /8 1/8 1/8 1 10/pk N /16 1/16 1/ /pk Description Unit Column nut, 1/16 in. 2/pk (µl) Description Needle Gauge/ Length (mm)/ Tip Syringe Needle and Repair Kit 0.5 Removable needle 23/70/cone tip N N Removable needle 26/70/bevelled cone tip Fixed needle 23/70/cone tip N Fixed needle, 23/70/cone tip N Fixed needle 26/70/cone tip N Fixed needle 23/70/cone tip N The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. 27
6 CrossLab Supplies for Shimadzu GC Systems Description Unit Column nut, slotted, 6-sided 2/pk Column nut, no slot, 6-sided 2/pk Needle Gauge/ (µl) Description Length (mm)/tip Syringe 5 Fixed needle 23/42/cone tip Needle 10 Removable needle 23/42/cone tip , 2/pk Removable needle 26/42/cone tip , 2/pk Fixed needle 23/42/cone tip Fixed needle, 23/42/cone tip The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page Agilent CrossLab Selection Guide
7 CrossLab Supplies for Thermo Scientific GC Systems Description Unit Column nut, stainless steel, split/splitless injector 2/pk Column nut, brass 2/pk BT239 or Needle (µl) Description Needle Gauge/ Length (mm)/tip Syringe TriPlus, AS in-needle 23/50/cone tip * TriPlus 5 Fixed needle 26/50/cone tip TriPlus, AS3000, 10 Fixed needle 23/50/cone tip AS2000, AS200, Fixed needle 26/50/cone tip D3711 AS800 Fixed needle 25/50/cone tip TriPlus, AS2000 Fixed needle 23/80/cone tip Fixed needle 26/80/cone tip /50/cone tip ** TriPlus, AS2000, AS200, AS800 TriPlus, AS2000 *Needle and plunger repair kit ** plunger *** needle 100 Fixed needle, Removable needle, 23/50/side hole tip *** The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page Agilent CrossLab Selection Guide
PTFE Tip, Gas-Tight Syringes
PTFE Tip, Suitable for gases or liquids. High accuracy of dispensed volumes. Interchangeable barrels, plungers, and tips extend performance and increase cost-effectiveness. Volume Needle Needle Needle
More informationGastight Syringes. A guide to syringe terminations and needle points can be found on page Series
Gastight Syringes Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit,
More information2014 Chromatography Supplies & Instruments Catalog
2014 Chromatography Supplies & Instruments Catalog http://www.scientifix.com.au ken@scientifix.com.au Fax: +61 (0)3 95437827 Page 1 Table of Contents Table Of Contents / How To Order.... 2 Who Is Visacon
More informationVials, Caps, Septa & Inserts. The Industry s Most Versatile Autosampler Vials
Vials, Caps, Septa & Inserts The Industry s Most Versatile Autosampler Vials The Industry s Most Versatile Autosampler Vials MicroLiter, a WHEATON Brand, offers proven autosampler vials and consumables
More informationConsumables PAL GC/GC-MS Sample Injector PAL LC/LC-MS Sample Injector
Consumables PAL GC/GC-MS Sample Injector PAL LC/LC-MS Sample Injector Identify the appropriate La-Pha-Pack product for your PAL autosampler. The brochure is devided in four fields of applications: HPLC
More informationAs a global leading supplier of sample vials, ALWSCI can supply a series of sample vials from 1ML to 1000ML. Both ODM & OEM business are optional.
Chinasepta ALWSCI is a global supplier of analytical field and lab supplies with high quality, good service and favorable price. We have wide customers including pharmaceutical, life science, chemistry,
More informationBig Mouth Crimp Top Vials, 12x32mm, 11mm Crimp Finish
Vials 32011L-1232A, 32011L-1232, 3211LE-1232A, 32011LE-1232 Finneran Products Certified For Science TM 40% larger opening prevents broken needles due to increased target area. Neck finish allows use of
More informationGenTechTM. Putting New Life Into Old Instruments Since 1996! Phone: Website: GenTechScientific.com
GenTechTM Putting New Life Into Old Instruments Since 1996! Phone: 585.492.1068 Website: GenTechScientific.com Email: Sales@GenTechScientific.com Gas Chromatograph & GC/MS Systems, Accessories, Kits, Parts,
More informationSnap Seal Vials, Patented, 12x32mm, 11mm Crimp Finish
Finneran Products Certified For Science TM Vials 31811-1232A, 31811-1232, 31811E-1232A, 31811E-1232 The Snap Seal Vial can be securely sealed with the patented Poly Crimp Seal, an aluminum crimp seal or
More informationMS Sample Vials Spring View Lane Plano, TX Toll free: Fax:
MS Sample Vials 1108 Spring View Lane Plano, TX 75075 Toll free: 866-528-4572 Fax: 732-412-4040 www.membrane-solutions.com MS Sample Vials MS Sample vial are made from first hydrolytical class, borosilicate
More informationSETonic. Microsyringes. made in Germany
SETonic Microsyrges 2018 SETonic Microsyrges Catalog 2018 Content Page No. Content 1 L-MARK Syrges 2 Technical Syrge Information 3 Agilent Autosampler Syrges 4 CTC PAL Autosampler Syrges 5 CTC PAL 3 Autosampler
More informationPostnova Analytics GmbH
Vials & Closures Postnova Analytics GmbH Catalogue Max-Planck-Str. 14 86899 Landsberg a. Lech Phone: 08191-985688-0 Fax: 08191-985688-99 info@postnova info@postnova.com www.postnova.com Content Vials,
More informationVials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab Consumables Manufacturer Laboratory Instruments
Vials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab Consumables Manufacturer Laboratory Instruments Septa Crimp Top Vials 20-60ml Vials Aluminum Caps NEW!! Pre-Slit PTFE / non-slit silicone Septa
More informationGlenco Gas/Liquid Syringes from Spectrum Chromatography
Glenco Gas/Liquid Syringes from Spectrum Chromatography D10122 180296 Copyright 1996 by Spectrum Chromatography PO Box 672026 Houston, TX 77267-2026 Phone: (281) 443-2900 (800) 459-9700 (US & Canada) Fax:
More informationAgilent GC-MS Maintenance:
Restek GC Accessories Agilent GC-MS Maintenance: Restek s Quick Reference Guide Replacement parts for Agilent ion sources now available. Optimize performance by upgrading ion source components and electron
More informationCTC Analytics Service Note August 2016 PAL3: Design change for Tools
To: VAR/Dealer/OEM World-Wide, PAL Systems Platform PAL3 Systems From: Toni Eberwein Date: August 11, 2016 Subject: Design change for Tools CTC Analytics Service Note August 2016 PAL3: Design change for
More informationSUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.
PRO BEAM Jr. EB cable plug connectors are designed to be installed onto jacketed fiber optic cable with KEVLAR strength members. The connector must be assembled using a cable plug connector shell kit,
More informationCapillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES
Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Maximize information while collecting and analyzing GC data Comprehensive two-dimensional GC, or
More informationVials & Syringes. Vials. Syringes
Vials & Syringes Vials Overview....................................................253 Septum Selection Guide.....................................253 Vial Size Quick Reference Chart..........................254-255
More informationSample Handling - Vials, Caps, Inserts, 96 Well Plates, Sealing Mats. Ordering Information - 2mL Crimp Vials, 12 x 32mm, 11mm Opening VT011L-1232
Agilent Autosampler Products Our glass products are borosilicate USP class 1 Strain point : 565 C Please note that some manufacturers refer to 2mL vials as 1.5mL or 1.8mL Our recommended vials, caps and
More informationNEW? VIALS. What s. look for this circle
VIALS Overview...............................................353 Septum Selection Guide................................353 Vial Size Quick Reference Chart.....................354-355 Crimp-Top Vials....................................356-357
More informationThe Complete Guide of Autosampler Vials, Caps & Inserts
The Complete Guide of Autosampler Vials, Caps & Inserts INSIDE: THE ONLY SOURCE OF RSA GLASS VIALS & INSERTS New Items Basik Brand MicroSolv Brand AQ & RSA Brand Headspace 96 Well RSA Plates Heavy Wall
More informationStandard Opening Screw Thread Vials, 12x32mm, 8-425mm Neck Finish
Vials 32008-1232A, 32008-1232, 32008E-1232A, 32008E-1232 Finneran Products Certified For Science TM Narrow opening allows use of 8-425mm closures and septa. Designed to work in a variety of autosampler
More informationHBS-AP ASSEMBLING INSTRUCTIONS
ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,
More informationElimination of Elevator Bounce
For the Agilent Archon Autosampler Rework Instructions CAUTION This kit is intended for use by Agilent Service personnel only. Elevator Removal 1 Open top cover. 2 Open front lower door. 3 Remove vial
More informationUSING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880
USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880 The following instructions explain how the i2i Absolute Black ink for making screen positives is installed on an
More informationChromacol. consumables for chromatography
Chromacol consumables for chromatography Contents New Products 1 WebSeal 2 Product Selection by Autosampler Instrument Select 5 Agilent TM Technologies 6 PerkinElmer TM 9 Shimadzu TM 12 Thermo Scientific
More information5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves
MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping
More informationProfiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis
Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis HT3 Application Note Introduction Volatile organic compounds, VOCs, present in liquid food products play a very
More informationSUPERSEDED. NOT the LATEST REVISION
Figure 1 OPTIMATE 2.5mm bayonet ceramic connector kits listed in Figure 1 are designed to be applied to fiber optic cable. Coupling Receptacle Kit 501381 1 is used to mate two bayonet connectors in free
More informationRead these instructions thoroughly before crimping any contacts.
PRO CRIMPER III Hand Crimping Tool Assembly 58583 1 consists of Die Assembly 58583 2 and PRO CRIMPER III Hand Crimping Tool Frame 354940 1. The die assembly consists of crimping dies and a locator assembly.
More informationDynamic Nanospray Probe (NSI-1) Installation Guide
Dynamic Nanospray Probe (NSI-1) Installation Guide This guide describes how to install the NSI-1 dynamic nanospray probe (see Figure 1) onto a TSQ Series or LTQ Series mass spectrometer and provides general
More informationVelocity Scientific Solutions
Snap Ring /Crimp Top Vials, 12x32mm, 11mm Crimp Finish Vials Neck finish allows use of Snap Top Caps, patented Poly Crimp Seals or standard aluminum seals. Snap Ring finish eliminates the need for crimping
More informationTermination Procedure
Connector Piece Parts Contact/Connector Head Twist On Nut MX MX Boot Procedure Chart Procedure Tool Required Tool Part Number Cable Preparation & Fiber Cleaning Jacket Stripper 86710-0004 Cable Preparation
More informationHP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version)
HP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version) For the following cartridges: 934, 934XL, 935, and 935XL Series 5869 Terminal Ave. I Colorado Springs, CO 80915 PH: 719-578-0506
More informationMetrology (0) PROMO 13.1E. Resolution:.0005" (0.01mm).0005" (0.01mm) Grads
Metrology PROMO 13.1E Automatic off after 5 minutes with no loss of position Accuracy meets DIN862 Resolution:.0005" (0.01mm).0005" (0.01mm) Grads Call 00 44 (0)1835 863501 today IP67 Electronic Calipers
More informationWhen to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules
To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer Test CCD 4-Color and Seq Fill Capillary Run Modules BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM 310 GENETIC
More informationREFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900
REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900 Thank you for purchasing an Ink2image bulk ink feed system. You have just taken the first step to enjoying the cost saving and superior performance
More informationJ D SQUARED INC. NOTCH MASTER Tube and Pipe Notcher Operating Instructions
Copyright (c) 2006 J D SQUARED INC. www.jd2.com NOTCH MASTER Tube and Pipe Notcher Operating Instructions Angled Notches PATENT PENDING Straight Notches Offset Notches Tube Clamp Slider Tube Clamp Exploded
More informationAgilent 7697A GC Headspace Sampler YOUR GENUINELY BETTER SOLUTION FOR VOLATILES ANALYSIS
Agilent 7697A GC Headspace Sampler YOUR GENUINELY BETTER SOLUTION FOR VOLATILES ANALYSIS AGILENT 7697A HEADSPACE SAMPLER A high performance system powered by intuitive software. Now there is a genuinely
More information.Sheath gas flow rate
This chapter provides infofolation on tuning the MS detector in the LC/ESI/MS mode using your analyte. You optimize the sensitivity of your analyte in the MS detector through an automatic procedure. The
More informationUsing Your Chip Priming Station
Using Your Chip Priming Station The Chip Priming Station (5065-4401), is for use with the Agilent 2100 Bioanalyzer Analysis Kits. Refer to Figure 1 on page 2 for a picture of the Chip Priming Station.
More informationUsing Your Chip Priming Station
s1 Using Your Chip Priming Station The Chip Priming Station, part number 5065-4401, is for use with the Agilent 2100 Bioanalyzer LabChip Kits. Refer to Figure 1 and 2 for a picture of the Chip Priming
More informationInstruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016
Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016 The DeepWater2 is heavier-duty a version of the PushPoint Sampler made of stainless steel pipe instead of SS
More informationMETRIC / IMPERIAL MINI-MAG LEVEL
Digital Mini-Mag Level 570 Series Measuring range 360 (4 x 90 ) Embedded magnets on three sides Resolution 0.05 Accuracy +/- 0.2 Standard 9V battery Dimensions: L60mm x H60mm x W35mm METRIC / IMPERIAL
More informationINSTALLING THE DRIVE SYSTEM
In addition to the hardware kit that you received with the QBOT, you will need the hardware in this kit to complete the installation on your frame. The hardware kit for the NewJoy frame includes: (5) 1/4
More informationonlinecomponents.com
Figure 1 PRO CRIMPER III Hand Crimping Tool Assembly 58603 1 consists of Die Assembly 58603 2 and PRO CRIMPER III Hand Tool Frame 354940 1. The die assembly consists of crimping dies and a locator assembly.
More informationAgilent 1200 Infinity Series
Agilent 1200 Infinity Series Specification Compendium Agilent Technologies Notices Agilent Technologies, Inc. 2010-2012, 2013 No part of this manual may be reproduced in any form or by any means (including
More informationReasons for reissue are in Section 6, REVISION SUMMARY.
Figure 1 This instruction sheet covers the application of OPTIMATE FSMA Fiber Optic Connector Types 905 and 906 for data and telecommunications applications. Base part numbers which apply to each type
More informationVarious Bolt Removal Process
Various Bolt Removal Process Introduction I have been climbing for over 25 years. The first bolt I placed in 1987 was a 5/16 Rawls carbon steel, split shank, button head in sandstone. Certainly the wrong
More informationAgilent InfinityLab LC Series. Specification Compendium. Agilent Technologies
Agilent InfinityLab LC Series Specification Compendium Agilent Technologies Notices Agilent Technologies, Inc. 2014-2015, 2016 No part of this manual may be reproduced in any form or by any means (including
More informationVarious Bolt Removal Process
Various Bolt Removal Process Introduction I have been climbing close to 30 years. The first bolt I placed in 1987 was a 5/16 Rawls carbon steel, split shank, button head in sandstone. Certainly the wrong
More informationInstallation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit
www.polyskid.com P. O. Drawer 349, Monticello, GA. 31064 Phone: 800-542-7659 Fax: 706-468-2881 E-Mail: polytech@polyskid.com Installation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit
More information동방하이테크상사 T.(02) F.(02)
2010-11-27 동방하이테크상사 http://www.allpump.co.kr T.(02)457-6292 F.(02)457-6293 125 125 100% PEEK 100% PEEK Inert, Biocompatible and Metal-Free Uniform Porosity, Longer Filtration Life Patented Upchurch Scientific
More informationRhino r VE/CE Pneumatic Level Detect Modules. Description S S. The assembly detects two conditions during the downward movement of the follower:
Rhino r VE/CE Pneumatic Level Detect Modules Description See Figure 1. Level Detect modules use roller plunger limit switches on guide rails to monitor the distance between the bottom of the follower and
More informationOTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL
Page 1 of 7 OTECO INC. MODEL 45 4 5,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 2 of 7 TABLE OF CONTENTS 1. Assembly Blowout 2. Repair Kit Contents & Technical Specifications 3. Disassembly
More informationW7MRI's Anderson Powerpole. Power Hub
W7MRI's Anderson Powerpole Power Hub This PDF is provided by K7JM at http://radio.mcdougallshome.net Don, W7MRI made up a nice small circuit board that holds 7 pairs of Anderson Powerpole connectors to
More informationVelocity Scientific Solutions
Snap Seal Vials, Patented, 12x32mm, 11mm Crimp Finish Vials The Snap Seal Vial can be securely sealed with the patented Poly Crimp Seal, an aluminum crimp seal or a variety of Snap Top Cap designs. More
More informationVials. Septum Selection Guide
Vials Septum Selection Guide Instrument Reference Chart Vial Size Quick Reference Chart Microsampling Vials & Inserts Crimp-Top Vials Screw-Thread Vials Certified Vials WISP Vials Headspace Vials Versa
More informationCall toll-free
NMR TUBES Providing superior quality NMR tubes for the marketplace for over 40 years. Performance is guaranteed by the Kimble design, manufacturing, and quality processes that certify for wall thickness,
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More informationVials and Caps. Vials and caps Catalog supplement Additional products Discontinued products Product changes. ... we Meet your Needs.
Vials and Caps Vials and Inserts Vials and caps Catalog supplement 2012 Additional products Discontinued products Product changes Closures and Septa Accessories... we Meet your Needs www.mn-net.com Additional
More informationLC/MS/MS. Page Header. triple quadrupole mass spectrometer.
LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry
More informationMaintenance & Parts list for:
Maintenance & Parts list for: Industrial gun GB 2 Juni 2017 This Maintenance & Parts list for industrial gun is prepared by : Winchester Europe Service V. Parbst & Søn as a comprehensive maintenance guide
More informationEpson T069 Refillable Cartridges
Epson T069 Refillable Cartridges Important new information is below Thank you for contacting Tech Support regarding your Epson T069 Cartridges. Our R & D department is currently testing those cartridges.
More informationFITTINGS & GAUGES 20,000 PSI
PRESSURE GAUGE Features 4" high visibility face with laminated safety glass dial cover Accurate within +/- 0.5% of full scale range Stainless steel case and internals Heavy-duty movement Glycerine-filled
More informationAutosampler Vials. 2mL and 4mL Autosampler Vials without Closures. 20mm Headspace Vials. Polypropylene Rack for 12 mm OD Vials
Autosampler Vials 1 2mL and 4mL Autosampler Vials without Closures Choice of clear KG-33 or amber 203 borosilicate glass Available with or without marking spots Made in the USA Made of the highest quality
More informationMAT MASTER TM SYSTEMS
FrameCo MAT MASTER TM SYSTEMS #14225 BEVEL MOUNT CUTTERS Welcome and thank you for purchasing a FrameCo Mat Master System. Through these instructions we will endeavour to show you the benefits of the system
More informationA socket contact support (supplied separately) must be installed onto the locator assembly.
Figure 1 PRO CRIMPER III Hand Tool Assembly 1976444 1 consists of PRO CRIMPER III Hand Tool Frame 354940 1 and Die Assembly 1976444 2. The tool assembly is used to crimp the contacts listed in Figure 1.
More informationMUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections
insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extention 2-3 Improved Fire Hydrant Inserting Extention
More informationPlumbing Part II - Hand Pump
Plumbing Part II - Hand Pump Nelson Riedel Nelson@NelsonsLocomotive.com Initial: 7/17/03 Last Revised: 06/06/2004 The hand pump located in the tender water tank is a backup pump should the axel pump fail
More informationNEW? VIALS. What s. look for this circle
VIALS Overview...............................................353 Septum Selection Guide................................353 Vial Size Quick Reference Chart.....................354-355 Crimp-Top Vials....................................356-357
More informationFlash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility
Flash chromatography MN Flash adsorbents a unique variety of phases Flash columns and cartridges from MACHEREY-NAGEL are available with all CHROMABOND SPE / Flash packings (more than 40 phases, e.g., C
More informationw w w. h d o n l i n e s h o p. d e AUTOMATIC COMPRESSION RELEASE TOOL GENERAL INSTALLATION -J04654 REV Kit Number Models
-J05 REV. 008-0- GENERAL Kit Number 98-08 Models AUTOMATIC COMPRESSION RELEASE TOOL For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More informationMAT MASTER TM SYSTEMS
FrameCo MAT MASTER TM SYSTEMS #14225 BEVEL MOUNT CUTTERS Welcome and thank you for purchasing a FrameCo Mat Master System. Through these instructions we will endeavour to show you the benefits of the system
More informationThe thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers.
The thin wall ESI tip appears unusually advantageous for ensuring stable ESI conditions and efficient ion transfers. Valaskovic, Kelleher, McLafferty Science (1996), 273, 1199 perfect zero-dead-volume
More informationDepending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12
XL Quilting Frame 1 Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12 Foot frame Printed 2 June 2014 Updated
More informationGeneral Information. Ball Curb Valve
General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)
More informationSnap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents
Snap Tabs, etc. Stainless Steel Helmets Snap Tabs, Chin Strap, and Earphone Retainers Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel Contents SSBTM-1 1.1 Snap Tabs, Chin Strap, and
More informationFully Automated Auto Scanning System VPD-ICPMS Expert
Fully Automated Auto Scanning System VPD-ICPMS Expert www.vpdicpms.com An indispensable tool for analysis of metallic impurities in Si wafer Developed in cooperation with Samsung Electronics Co., Ltd.
More informationChin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents
Chin Strap Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets Contents BTM-1 1.1 Chin Strap BTM-4 1.2.3.1 Preparation BTM-1 1.1.1 Chin Strap Removal BTM-4 1.2.3.2 Disassembly BTM-1 BTM-2
More informationTOOLS AND INSTALLATION
TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and
More information.red Chromatography Vials
Crimp top vials and caps Large opening vials with 11mm crimp neck finish Excellent for long term storage Clear vials made from Type I Class A and B glass (33/51 expansion) Requires crimper (and decapper)
More informationTechnical Know-How Update
Guidelines for Safe & Effective Use Introduction The MBX Bristle Blaster is a new, easy to use, hand-held surface preparation tool suitable for use on a variety of substrates including metals, rubbers
More informationPACKING LIST MACO V-5000
PACKING LIST MACO V-5000 PART QTY O.D. SIZE LENGTH DESCRIPTION CHECKLIST T47P 4 5/8.050 36 Aluminum Tubing _ T43P 1 7/8.050 48 Aluminum Tubing _ T18P 1 3/4.050 48 Aluminum Tubing _ T15P 1 5/8.050 48 Aluminum
More informationDRAFT TANZANIA STANDARD MEDC 10(5692) P3 - SPECIFICATION FOR HONEY EXTRACTOR, RADIAL TYPE
DRAFT TANZANIA STANDARD MEDC 10(5692) P3 - SPECIFICATION FOR HONEY EXTRACTOR, RADIAL TYPE TBS 2018 Draft Edition 1 0. FOREWORDS Honey extractors enable bee-keepers to extract the maximum quantity of honey
More informationCambridge International Examinations Cambridge International General Certificate of Secondary Education
Cambridge International Examinations Cambridge International General Certificate of Secondary Education *9823048459* DESIGN AND TECHNOLOGY 0445/31 Paper 3 Resistant Materials October/November 2016 1 hour
More informationI-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove
WARNING Read and understand all instructions before attempting to install any Victaulic piping products. These products must be used only on pipe that is prepared to Victaulic Advanced Groove System (AGS)
More informationExpert. Elemental Scientific VPD-ICPMS. Fully Automated Auto Scanning System ICP ICPMS AA
Expert VPD-ICPMS Fully Automated Auto Scanning System Elemental Scientific ICP ICPMS AA Expert Features An indispensable tool for the determination of metal impurities in Si wafer Expert automates routine
More informationProtractors / Clinometers / Spirit levels
Protractors / Clinometers / Spirit levels Accuracy of clinometers/spirit levels according DIN 877 Graduation Flatness (µm) µm/m " (L = length in ) 50 10 4 + L / 250 > 50-200 > 10-40 8 + L / 125 > 200 >
More informationCambridge International Examinations Cambridge International General Certificate of Secondary Education
www.xtremepapers.com Cambridge International Examinations Cambridge International General Certificate of Secondary Education *2587041388* DESIGN AND TECHNOLOGY 0445/33 Paper 3 Resistant Materials October/November
More informationINSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE
INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE The material included in this kit is to be used for WC styles of brakes that are designed or upgraded to the EP
More informationTNC SERIES General... 4 Interface... 5 Characteristics...6-7
CONTENTS PAGE TNC SERIES General... 4 Interface... 5 Characteristics...6-7 TNC 50 Ω SERIES Plugs...8-9 Jacks...0- Jacks and receptacles... Receptacles...-4 Adapters... 5 Caps... 6 TNC 75 Ω SERIES Plugs...
More informationCrimping Die Assemblies , , , , , , , , and 69653
Crimping Die Assemblies 46754-2, 46755-2, 46756-2, 46757-2, 46758-2, 46759-2, 46760-2, 59870-1, and 69653 Instruction Sheet 408-1602 10 NOV 16 Rev C 1. INTRODUCTION WIRE SIZE (MCM) (1) CMA (Circular Mil
More informationC-1650P 16 Gauge, 1/2 Medium Crown Stapler
C-1650P 16 Gauge, 1/2 Medium Crown Stapler MANUAL/WARNING: IMPORTANT PLEASE READ BEFORE USING TOOL Please read the following operating instructions manual. Refer to this manual for safety, adjustment and
More informationRadioisotope Shielded Work Station Components Models to
Radioisotope Shielded Work Station Components Models 67-752 to 67-761! Provides optimum work conditions when using high energy nuclides! Offers maximum protection and versatility! Sold as separate components
More informationTools and Tips: ( 1 )
Tools and Tips: As you build instructions will show in my many picture manual how to assemble. You can use your own methods as you desire, my results are very good. A smooth, flat work surface is very
More informationNow available at participating Feeney (2/14) AF# A. Stores. 1/8'' Stainless Steel Cable Assemblies to Enhance Any Railing and Any View!
2014 Feeney (2/14) AF# 2009-236A Now available at participating Stores 1/8'' Stainless Steel Cable Assemblies to Enhance Any Railing and Any View! Easy-to-install, prefabricated cable assemblies are an
More informationKAITE KWIK CHECK Rev.01
KAITE KWIK CHECK Rev.01 Rapid read hole measuring gauge for all industries. spray nozzle experts for the processing industry KAITE LTD elegance in design 2 KAITE KWIK CHECK Hole Gauge The KAITE KWIK CHECK
More informationC-1116LMA - Automatic Stapler w/ Long Mag
C-1116LMA - Automatic Stapler w/ Long Mag MANUAL/WARNING: IMPORTANT PLEASE READ BEFORE USING TOOL Please read the following operating instructions manual. Refer to this manual for safety, adjustment and
More information