CrossLab Autosampler Syringes

Size: px
Start display at page:

Download "CrossLab Autosampler Syringes"

Transcription

1 CrossLab Product Introductions CrossLab Autosampler Syringes With a broad selection of syringes for auto injection, CrossLab autosampler syringes provide what you need for accurate and effective sampling. CrossLab syringes meet all fit, form, and function criteria for specific autosampler models. Agilent delivers more value in every autosampler syringe: Lot number printed directly on the barrel with a corresponding Certificate of Conformance Illuminating backing strip, for effortless viewing of the volume scale Environmentally friendly packaging and improved design that reduces waste Individually packaged for contaminant-free use right out of the box Tips & Tools Replace syringe if dirt is noticeable, syringe cannot be cleaned or plunger doesn't slide easily. Replace needle if septa wear is abnormal or needle is clogged. Typical Needle Gauge Dimensions OD ID Gauge mm inches mm inches

2 CrossLab Product Introductions Needle Gauge 23 (0.64 mm) Single Gauge 23 (0.64 mm) Packed column injector ports Split/splitless injector ports 26 (0.47 mm) Single Gauge 26 (0.47 mm) Packed column injector ports Split/splitless injector ports Needle Termination Needle terminations are available in fixed or removable, with various tip styles. Fixed (cemented) Tips & Tools Follow manufacturer's recommendation for syringe cleaning and regularly inspect syringe barrel for sample build-up and needle tip for wear. Economical, reproducible injections for autosamplers Preferred for applications requiring trace level samples Recommended for use where probability of needle bending is minimal Can be heated up to 70 C Removable needle Versatile option for injections Needle can be replaced if damaged or clogged Allows needle to be changed for different applications Can be heated up to 120 C 8 Agilent CrossLab Selection Guide

3 CrossLab Supplies for Bruker, Varian* GC Systems Description Unit Column nut, brass, 1177, 1079, 1061, or 1041 injector 2/pk Column nut, stainless steel, 1093 injector 2/pk CP Varian* CP8400, CP8410, CP9010, CP9050 Varian* 8035, 8100, 8200 Description Needle Gauge/Length (mm)/tip Syringe Needle 10 Fixed needle 23/50/cone tip SG Fixed needle 26/50/bevel tip Removable needle 26/50/cone tip SG , 2/pk Fixed needle, 26/53/single hole tip /53/single hole tip , 2/pk (µl) Removable needle, *Formerly Varian GC systems, now Bruker products The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page

4 CrossLab Supplies for CTC Analytics GC Autosamplers CrossLab CTC Autosampler Syringes Agilent's CrossLab portfolio includes a variety of syringes compatible with CTC Analytics GC PAL and CombiPAL systems. Syringe capacities from 0.5 µl to 2.5 ml Fixed and removable needles Several needle tip styles to suit your application requirements High temperature syringes for headspace application with temperatures up to 150 C PTFE plunger seal option for smooth, leak-free operation Syringe specifications are matched to CTC holders to ensure proper fit and reliable functioning Autosampler Syringes for CTC CombiPAL and GC PAL, 1/pk (µl) Description Needle Gauge/Length (mm)/tip Syringe or Needle 0.5 -in-needle 23/50/cone tip * 5 Fixed needle 23/50/cone tip Fixed needle 26/50/cone tip Fixed needle 23/50/cone tip Fixed needle 25/50/cone tip Fixed needle 26/50/cone tip Fixed needle, 26/50/cone tip ** Fixed needle 26/50/bevel tip Fixed needle 26/50/cone tip Fixed needle, 23/50/cone tip Removable needle, 23/50/side hole tip *** Fixed needle 26/50/cone tip Fixed needle, 26/50/cone tip (ml) Description Needle Gauge/Length (mm)/tip Syringe 1 Fixed needle,, headspace 23/56/side hole tip Fixed needle,, headspace 23/56/side hole tip *Needle and plunger repair kit ** plunger *** needle 41

5 CrossLab Supplies for PerkinElmer GC Systems Vespel Capillary Column Ferrules Fitting Size (in.) Ferrule ID (mm) Column ID (mm) Hole Unit 1/ mm ID 1 10/pk or smaller 1/ /pk / /pk / /pk Vespel Packed Column Ferrules Fitting Size (in.) Ferrule ID (in.) Column OD (in.) Hole Unit 1/4 1/4 1/4 1 10/pk N /8 1/8 1/8 1 10/pk N /16 1/16 1/ /pk Description Unit Column nut, 1/16 in. 2/pk (µl) Description Needle Gauge/ Length (mm)/ Tip Syringe Needle and Repair Kit 0.5 Removable needle 23/70/cone tip N N Removable needle 26/70/bevelled cone tip Fixed needle 23/70/cone tip N Fixed needle, 23/70/cone tip N Fixed needle 26/70/cone tip N Fixed needle 23/70/cone tip N The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. 27

6 CrossLab Supplies for Shimadzu GC Systems Description Unit Column nut, slotted, 6-sided 2/pk Column nut, no slot, 6-sided 2/pk Needle Gauge/ (µl) Description Length (mm)/tip Syringe 5 Fixed needle 23/42/cone tip Needle 10 Removable needle 23/42/cone tip , 2/pk Removable needle 26/42/cone tip , 2/pk Fixed needle 23/42/cone tip Fixed needle, 23/42/cone tip The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page Agilent CrossLab Selection Guide

7 CrossLab Supplies for Thermo Scientific GC Systems Description Unit Column nut, stainless steel, split/splitless injector 2/pk Column nut, brass 2/pk BT239 or Needle (µl) Description Needle Gauge/ Length (mm)/tip Syringe TriPlus, AS in-needle 23/50/cone tip * TriPlus 5 Fixed needle 26/50/cone tip TriPlus, AS3000, 10 Fixed needle 23/50/cone tip AS2000, AS200, Fixed needle 26/50/cone tip D3711 AS800 Fixed needle 25/50/cone tip TriPlus, AS2000 Fixed needle 23/80/cone tip Fixed needle 26/80/cone tip /50/cone tip ** TriPlus, AS2000, AS200, AS800 TriPlus, AS2000 *Needle and plunger repair kit ** plunger *** needle 100 Fixed needle, Removable needle, 23/50/side hole tip *** The cross references to the original equipment manufacturer () part numbers listed here serve as a recommendation that the CrossLab products are viable alternatives to products. CrossLab products are compatible with the corresponding instruments, although in some cases, the CrossLab products may have slightly different designs as compared to the counterparts. Looking for Autosampler Vials? Please see page Agilent CrossLab Selection Guide

PTFE Tip, Gas-Tight Syringes

PTFE Tip, Gas-Tight Syringes PTFE Tip, Suitable for gases or liquids. High accuracy of dispensed volumes. Interchangeable barrels, plungers, and tips extend performance and increase cost-effectiveness. Volume Needle Needle Needle

More information

Gastight Syringes. A guide to syringe terminations and needle points can be found on page Series

Gastight Syringes. A guide to syringe terminations and needle points can be found on page Series Gastight Syringes Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit,

More information

2014 Chromatography Supplies & Instruments Catalog

2014 Chromatography Supplies & Instruments Catalog 2014 Chromatography Supplies & Instruments Catalog http://www.scientifix.com.au ken@scientifix.com.au Fax: +61 (0)3 95437827 Page 1 Table of Contents Table Of Contents / How To Order.... 2 Who Is Visacon

More information

Vials, Caps, Septa & Inserts. The Industry s Most Versatile Autosampler Vials

Vials, Caps, Septa & Inserts. The Industry s Most Versatile Autosampler Vials Vials, Caps, Septa & Inserts The Industry s Most Versatile Autosampler Vials The Industry s Most Versatile Autosampler Vials MicroLiter, a WHEATON Brand, offers proven autosampler vials and consumables

More information

Consumables PAL GC/GC-MS Sample Injector PAL LC/LC-MS Sample Injector

Consumables PAL GC/GC-MS Sample Injector PAL LC/LC-MS Sample Injector Consumables PAL GC/GC-MS Sample Injector PAL LC/LC-MS Sample Injector Identify the appropriate La-Pha-Pack product for your PAL autosampler. The brochure is devided in four fields of applications: HPLC

More information

As a global leading supplier of sample vials, ALWSCI can supply a series of sample vials from 1ML to 1000ML. Both ODM & OEM business are optional.

As a global leading supplier of sample vials, ALWSCI can supply a series of sample vials from 1ML to 1000ML. Both ODM & OEM business are optional. Chinasepta ALWSCI is a global supplier of analytical field and lab supplies with high quality, good service and favorable price. We have wide customers including pharmaceutical, life science, chemistry,

More information

Big Mouth Crimp Top Vials, 12x32mm, 11mm Crimp Finish

Big Mouth Crimp Top Vials, 12x32mm, 11mm Crimp Finish Vials 32011L-1232A, 32011L-1232, 3211LE-1232A, 32011LE-1232 Finneran Products Certified For Science TM 40% larger opening prevents broken needles due to increased target area. Neck finish allows use of

More information

GenTechTM. Putting New Life Into Old Instruments Since 1996! Phone: Website: GenTechScientific.com

GenTechTM. Putting New Life Into Old Instruments Since 1996! Phone: Website: GenTechScientific.com GenTechTM Putting New Life Into Old Instruments Since 1996! Phone: 585.492.1068 Website: GenTechScientific.com Email: Sales@GenTechScientific.com Gas Chromatograph & GC/MS Systems, Accessories, Kits, Parts,

More information

Snap Seal Vials, Patented, 12x32mm, 11mm Crimp Finish

Snap Seal Vials, Patented, 12x32mm, 11mm Crimp Finish Finneran Products Certified For Science TM Vials 31811-1232A, 31811-1232, 31811E-1232A, 31811E-1232 The Snap Seal Vial can be securely sealed with the patented Poly Crimp Seal, an aluminum crimp seal or

More information

MS Sample Vials Spring View Lane Plano, TX Toll free: Fax:

MS Sample Vials Spring View Lane Plano, TX Toll free: Fax: MS Sample Vials 1108 Spring View Lane Plano, TX 75075 Toll free: 866-528-4572 Fax: 732-412-4040 www.membrane-solutions.com MS Sample Vials MS Sample vial are made from first hydrolytical class, borosilicate

More information

SETonic. Microsyringes. made in Germany

SETonic. Microsyringes.     made in Germany SETonic Microsyrges 2018 SETonic Microsyrges Catalog 2018 Content Page No. Content 1 L-MARK Syrges 2 Technical Syrge Information 3 Agilent Autosampler Syrges 4 CTC PAL Autosampler Syrges 5 CTC PAL 3 Autosampler

More information

Postnova Analytics GmbH

Postnova Analytics GmbH Vials & Closures Postnova Analytics GmbH Catalogue Max-Planck-Str. 14 86899 Landsberg a. Lech Phone: 08191-985688-0 Fax: 08191-985688-99 info@postnova info@postnova.com www.postnova.com Content Vials,

More information

Vials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab Consumables Manufacturer Laboratory Instruments

Vials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab Consumables Manufacturer Laboratory Instruments Vials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab Consumables Manufacturer Laboratory Instruments Septa Crimp Top Vials 20-60ml Vials Aluminum Caps NEW!! Pre-Slit PTFE / non-slit silicone Septa

More information

Glenco Gas/Liquid Syringes from Spectrum Chromatography

Glenco Gas/Liquid Syringes from Spectrum Chromatography Glenco Gas/Liquid Syringes from Spectrum Chromatography D10122 180296 Copyright 1996 by Spectrum Chromatography PO Box 672026 Houston, TX 77267-2026 Phone: (281) 443-2900 (800) 459-9700 (US & Canada) Fax:

More information

Agilent GC-MS Maintenance:

Agilent GC-MS Maintenance: Restek GC Accessories Agilent GC-MS Maintenance: Restek s Quick Reference Guide Replacement parts for Agilent ion sources now available. Optimize performance by upgrading ion source components and electron

More information

CTC Analytics Service Note August 2016 PAL3: Design change for Tools

CTC Analytics Service Note August 2016 PAL3: Design change for Tools To: VAR/Dealer/OEM World-Wide, PAL Systems Platform PAL3 Systems From: Toni Eberwein Date: August 11, 2016 Subject: Design change for Tools CTC Analytics Service Note August 2016 PAL3: Design change for

More information

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY. PRO BEAM Jr. EB cable plug connectors are designed to be installed onto jacketed fiber optic cable with KEVLAR strength members. The connector must be assembled using a cable plug connector shell kit,

More information

Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES

Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Maximize information while collecting and analyzing GC data Comprehensive two-dimensional GC, or

More information

Vials & Syringes. Vials. Syringes

Vials & Syringes. Vials. Syringes Vials & Syringes Vials Overview....................................................253 Septum Selection Guide.....................................253 Vial Size Quick Reference Chart..........................254-255

More information

Sample Handling - Vials, Caps, Inserts, 96 Well Plates, Sealing Mats. Ordering Information - 2mL Crimp Vials, 12 x 32mm, 11mm Opening VT011L-1232

Sample Handling - Vials, Caps, Inserts, 96 Well Plates, Sealing Mats. Ordering Information - 2mL Crimp Vials, 12 x 32mm, 11mm Opening VT011L-1232 Agilent Autosampler Products Our glass products are borosilicate USP class 1 Strain point : 565 C Please note that some manufacturers refer to 2mL vials as 1.5mL or 1.8mL Our recommended vials, caps and

More information

NEW? VIALS. What s. look for this circle

NEW? VIALS. What s. look for this circle VIALS Overview...............................................353 Septum Selection Guide................................353 Vial Size Quick Reference Chart.....................354-355 Crimp-Top Vials....................................356-357

More information

The Complete Guide of Autosampler Vials, Caps & Inserts

The Complete Guide of Autosampler Vials, Caps & Inserts The Complete Guide of Autosampler Vials, Caps & Inserts INSIDE: THE ONLY SOURCE OF RSA GLASS VIALS & INSERTS New Items Basik Brand MicroSolv Brand AQ & RSA Brand Headspace 96 Well RSA Plates Heavy Wall

More information

Standard Opening Screw Thread Vials, 12x32mm, 8-425mm Neck Finish

Standard Opening Screw Thread Vials, 12x32mm, 8-425mm Neck Finish Vials 32008-1232A, 32008-1232, 32008E-1232A, 32008E-1232 Finneran Products Certified For Science TM Narrow opening allows use of 8-425mm closures and septa. Designed to work in a variety of autosampler

More information

HBS-AP ASSEMBLING INSTRUCTIONS

HBS-AP ASSEMBLING INSTRUCTIONS ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,

More information

Elimination of Elevator Bounce

Elimination of Elevator Bounce For the Agilent Archon Autosampler Rework Instructions CAUTION This kit is intended for use by Agilent Service personnel only. Elevator Removal 1 Open top cover. 2 Open front lower door. 3 Remove vial

More information

USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880

USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880 USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 3800 & 3880 The following instructions explain how the i2i Absolute Black ink for making screen positives is installed on an

More information

Chromacol. consumables for chromatography

Chromacol. consumables for chromatography Chromacol consumables for chromatography Contents New Products 1 WebSeal 2 Product Selection by Autosampler Instrument Select 5 Agilent TM Technologies 6 PerkinElmer TM 9 Shimadzu TM 12 Thermo Scientific

More information

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping

More information

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis HT3 Application Note Introduction Volatile organic compounds, VOCs, present in liquid food products play a very

More information

SUPERSEDED. NOT the LATEST REVISION

SUPERSEDED. NOT the LATEST REVISION Figure 1 OPTIMATE 2.5mm bayonet ceramic connector kits listed in Figure 1 are designed to be applied to fiber optic cable. Coupling Receptacle Kit 501381 1 is used to mate two bayonet connectors in free

More information

Read these instructions thoroughly before crimping any contacts.

Read these instructions thoroughly before crimping any contacts. PRO CRIMPER III Hand Crimping Tool Assembly 58583 1 consists of Die Assembly 58583 2 and PRO CRIMPER III Hand Crimping Tool Frame 354940 1. The die assembly consists of crimping dies and a locator assembly.

More information

Dynamic Nanospray Probe (NSI-1) Installation Guide

Dynamic Nanospray Probe (NSI-1) Installation Guide Dynamic Nanospray Probe (NSI-1) Installation Guide This guide describes how to install the NSI-1 dynamic nanospray probe (see Figure 1) onto a TSQ Series or LTQ Series mass spectrometer and provides general

More information

Velocity Scientific Solutions

Velocity Scientific Solutions Snap Ring /Crimp Top Vials, 12x32mm, 11mm Crimp Finish Vials Neck finish allows use of Snap Top Caps, patented Poly Crimp Seals or standard aluminum seals. Snap Ring finish eliminates the need for crimping

More information

Termination Procedure

Termination Procedure Connector Piece Parts Contact/Connector Head Twist On Nut MX MX Boot Procedure Chart Procedure Tool Required Tool Part Number Cable Preparation & Fiber Cleaning Jacket Stripper 86710-0004 Cable Preparation

More information

HP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version)

HP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version) HP 564 and 920 InkJet Cartridges Refill Instructions (Professional Version) For the following cartridges: 934, 934XL, 935, and 935XL Series 5869 Terminal Ave. I Colorado Springs, CO 80915 PH: 719-578-0506

More information

Metrology (0) PROMO 13.1E. Resolution:.0005" (0.01mm).0005" (0.01mm) Grads

Metrology (0) PROMO 13.1E. Resolution:.0005 (0.01mm).0005 (0.01mm) Grads Metrology PROMO 13.1E Automatic off after 5 minutes with no loss of position Accuracy meets DIN862 Resolution:.0005" (0.01mm).0005" (0.01mm) Grads Call 00 44 (0)1835 863501 today IP67 Electronic Calipers

More information

When to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules

When to Perform the Test CCD 4-Color and/or Seq Fill Capillary Run Modules To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer Test CCD 4-Color and Seq Fill Capillary Run Modules BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM 310 GENETIC

More information

REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900

REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900 REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 4900 Thank you for purchasing an Ink2image bulk ink feed system. You have just taken the first step to enjoying the cost saving and superior performance

More information

J D SQUARED INC. NOTCH MASTER Tube and Pipe Notcher Operating Instructions

J D SQUARED INC.   NOTCH MASTER Tube and Pipe Notcher Operating Instructions Copyright (c) 2006 J D SQUARED INC. www.jd2.com NOTCH MASTER Tube and Pipe Notcher Operating Instructions Angled Notches PATENT PENDING Straight Notches Offset Notches Tube Clamp Slider Tube Clamp Exploded

More information

Agilent 7697A GC Headspace Sampler YOUR GENUINELY BETTER SOLUTION FOR VOLATILES ANALYSIS

Agilent 7697A GC Headspace Sampler YOUR GENUINELY BETTER SOLUTION FOR VOLATILES ANALYSIS Agilent 7697A GC Headspace Sampler YOUR GENUINELY BETTER SOLUTION FOR VOLATILES ANALYSIS AGILENT 7697A HEADSPACE SAMPLER A high performance system powered by intuitive software. Now there is a genuinely

More information

.Sheath gas flow rate

.Sheath gas flow rate This chapter provides infofolation on tuning the MS detector in the LC/ESI/MS mode using your analyte. You optimize the sensitivity of your analyte in the MS detector through an automatic procedure. The

More information

Using Your Chip Priming Station

Using Your Chip Priming Station Using Your Chip Priming Station The Chip Priming Station (5065-4401), is for use with the Agilent 2100 Bioanalyzer Analysis Kits. Refer to Figure 1 on page 2 for a picture of the Chip Priming Station.

More information

Using Your Chip Priming Station

Using Your Chip Priming Station s1 Using Your Chip Priming Station The Chip Priming Station, part number 5065-4401, is for use with the Agilent 2100 Bioanalyzer LabChip Kits. Refer to Figure 1 and 2 for a picture of the Chip Priming

More information

Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016

Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016 Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016 The DeepWater2 is heavier-duty a version of the PushPoint Sampler made of stainless steel pipe instead of SS

More information

METRIC / IMPERIAL MINI-MAG LEVEL

METRIC / IMPERIAL MINI-MAG LEVEL Digital Mini-Mag Level 570 Series Measuring range 360 (4 x 90 ) Embedded magnets on three sides Resolution 0.05 Accuracy +/- 0.2 Standard 9V battery Dimensions: L60mm x H60mm x W35mm METRIC / IMPERIAL

More information

INSTALLING THE DRIVE SYSTEM

INSTALLING THE DRIVE SYSTEM In addition to the hardware kit that you received with the QBOT, you will need the hardware in this kit to complete the installation on your frame. The hardware kit for the NewJoy frame includes: (5) 1/4

More information

onlinecomponents.com

onlinecomponents.com Figure 1 PRO CRIMPER III Hand Crimping Tool Assembly 58603 1 consists of Die Assembly 58603 2 and PRO CRIMPER III Hand Tool Frame 354940 1. The die assembly consists of crimping dies and a locator assembly.

More information

Agilent 1200 Infinity Series

Agilent 1200 Infinity Series Agilent 1200 Infinity Series Specification Compendium Agilent Technologies Notices Agilent Technologies, Inc. 2010-2012, 2013 No part of this manual may be reproduced in any form or by any means (including

More information

Reasons for reissue are in Section 6, REVISION SUMMARY.

Reasons for reissue are in Section 6, REVISION SUMMARY. Figure 1 This instruction sheet covers the application of OPTIMATE FSMA Fiber Optic Connector Types 905 and 906 for data and telecommunications applications. Base part numbers which apply to each type

More information

Various Bolt Removal Process

Various Bolt Removal Process Various Bolt Removal Process Introduction I have been climbing for over 25 years. The first bolt I placed in 1987 was a 5/16 Rawls carbon steel, split shank, button head in sandstone. Certainly the wrong

More information

Agilent InfinityLab LC Series. Specification Compendium. Agilent Technologies

Agilent InfinityLab LC Series. Specification Compendium. Agilent Technologies Agilent InfinityLab LC Series Specification Compendium Agilent Technologies Notices Agilent Technologies, Inc. 2014-2015, 2016 No part of this manual may be reproduced in any form or by any means (including

More information

Various Bolt Removal Process

Various Bolt Removal Process Various Bolt Removal Process Introduction I have been climbing close to 30 years. The first bolt I placed in 1987 was a 5/16 Rawls carbon steel, split shank, button head in sandstone. Certainly the wrong

More information

Installation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit

Installation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit www.polyskid.com P. O. Drawer 349, Monticello, GA. 31064 Phone: 800-542-7659 Fax: 706-468-2881 E-Mail: polytech@polyskid.com Installation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit

More information

동방하이테크상사 T.(02) F.(02)

동방하이테크상사   T.(02) F.(02) 2010-11-27 동방하이테크상사 http://www.allpump.co.kr T.(02)457-6292 F.(02)457-6293 125 125 100% PEEK 100% PEEK Inert, Biocompatible and Metal-Free Uniform Porosity, Longer Filtration Life Patented Upchurch Scientific

More information

Rhino r VE/CE Pneumatic Level Detect Modules. Description S S. The assembly detects two conditions during the downward movement of the follower:

Rhino r VE/CE Pneumatic Level Detect Modules. Description S S. The assembly detects two conditions during the downward movement of the follower: Rhino r VE/CE Pneumatic Level Detect Modules Description See Figure 1. Level Detect modules use roller plunger limit switches on guide rails to monitor the distance between the bottom of the follower and

More information

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 1 of 7 OTECO INC. MODEL 45 4 5,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 2 of 7 TABLE OF CONTENTS 1. Assembly Blowout 2. Repair Kit Contents & Technical Specifications 3. Disassembly

More information

W7MRI's Anderson Powerpole. Power Hub

W7MRI's Anderson Powerpole. Power Hub W7MRI's Anderson Powerpole Power Hub This PDF is provided by K7JM at http://radio.mcdougallshome.net Don, W7MRI made up a nice small circuit board that holds 7 pairs of Anderson Powerpole connectors to

More information

Velocity Scientific Solutions

Velocity Scientific Solutions Snap Seal Vials, Patented, 12x32mm, 11mm Crimp Finish Vials The Snap Seal Vial can be securely sealed with the patented Poly Crimp Seal, an aluminum crimp seal or a variety of Snap Top Cap designs. More

More information

Vials. Septum Selection Guide

Vials. Septum Selection Guide Vials Septum Selection Guide Instrument Reference Chart Vial Size Quick Reference Chart Microsampling Vials & Inserts Crimp-Top Vials Screw-Thread Vials Certified Vials WISP Vials Headspace Vials Versa

More information

Call toll-free

Call toll-free NMR TUBES Providing superior quality NMR tubes for the marketplace for over 40 years. Performance is guaranteed by the Kimble design, manufacturing, and quality processes that certify for wall thickness,

More information

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment

More information

Vials and Caps. Vials and caps Catalog supplement Additional products Discontinued products Product changes. ... we Meet your Needs.

Vials and Caps. Vials and caps Catalog supplement Additional products Discontinued products Product changes. ... we Meet your Needs. Vials and Caps Vials and Inserts Vials and caps Catalog supplement 2012 Additional products Discontinued products Product changes Closures and Septa Accessories... we Meet your Needs www.mn-net.com Additional

More information

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

LC/MS/MS. Page Header. triple quadrupole mass spectrometer. LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry

More information

Maintenance & Parts list for:

Maintenance & Parts list for: Maintenance & Parts list for: Industrial gun GB 2 Juni 2017 This Maintenance & Parts list for industrial gun is prepared by : Winchester Europe Service V. Parbst & Søn as a comprehensive maintenance guide

More information

Epson T069 Refillable Cartridges

Epson T069 Refillable Cartridges Epson T069 Refillable Cartridges Important new information is below Thank you for contacting Tech Support regarding your Epson T069 Cartridges. Our R & D department is currently testing those cartridges.

More information

FITTINGS & GAUGES 20,000 PSI

FITTINGS & GAUGES 20,000 PSI PRESSURE GAUGE Features 4" high visibility face with laminated safety glass dial cover Accurate within +/- 0.5% of full scale range Stainless steel case and internals Heavy-duty movement Glycerine-filled

More information

Autosampler Vials. 2mL and 4mL Autosampler Vials without Closures. 20mm Headspace Vials. Polypropylene Rack for 12 mm OD Vials

Autosampler Vials. 2mL and 4mL Autosampler Vials without Closures. 20mm Headspace Vials. Polypropylene Rack for 12 mm OD Vials Autosampler Vials 1 2mL and 4mL Autosampler Vials without Closures Choice of clear KG-33 or amber 203 borosilicate glass Available with or without marking spots Made in the USA Made of the highest quality

More information

MAT MASTER TM SYSTEMS

MAT MASTER TM SYSTEMS FrameCo MAT MASTER TM SYSTEMS #14225 BEVEL MOUNT CUTTERS Welcome and thank you for purchasing a FrameCo Mat Master System. Through these instructions we will endeavour to show you the benefits of the system

More information

A socket contact support (supplied separately) must be installed onto the locator assembly.

A socket contact support (supplied separately) must be installed onto the locator assembly. Figure 1 PRO CRIMPER III Hand Tool Assembly 1976444 1 consists of PRO CRIMPER III Hand Tool Frame 354940 1 and Die Assembly 1976444 2. The tool assembly is used to crimp the contacts listed in Figure 1.

More information

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extention 2-3 Improved Fire Hydrant Inserting Extention

More information

Plumbing Part II - Hand Pump

Plumbing Part II - Hand Pump Plumbing Part II - Hand Pump Nelson Riedel Nelson@NelsonsLocomotive.com Initial: 7/17/03 Last Revised: 06/06/2004 The hand pump located in the tender water tank is a backup pump should the axel pump fail

More information

NEW? VIALS. What s. look for this circle

NEW? VIALS. What s. look for this circle VIALS Overview...............................................353 Septum Selection Guide................................353 Vial Size Quick Reference Chart.....................354-355 Crimp-Top Vials....................................356-357

More information

Flash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility

Flash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility Flash chromatography MN Flash adsorbents a unique variety of phases Flash columns and cartridges from MACHEREY-NAGEL are available with all CHROMABOND SPE / Flash packings (more than 40 phases, e.g., C

More information

w w w. h d o n l i n e s h o p. d e AUTOMATIC COMPRESSION RELEASE TOOL GENERAL INSTALLATION -J04654 REV Kit Number Models

w w w. h d o n l i n e s h o p. d e AUTOMATIC COMPRESSION RELEASE TOOL GENERAL INSTALLATION -J04654 REV Kit Number Models -J05 REV. 008-0- GENERAL Kit Number 98-08 Models AUTOMATIC COMPRESSION RELEASE TOOL For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com

More information

MAT MASTER TM SYSTEMS

MAT MASTER TM SYSTEMS FrameCo MAT MASTER TM SYSTEMS #14225 BEVEL MOUNT CUTTERS Welcome and thank you for purchasing a FrameCo Mat Master System. Through these instructions we will endeavour to show you the benefits of the system

More information

The thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers.

The thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers. The thin wall ESI tip appears unusually advantageous for ensuring stable ESI conditions and efficient ion transfers. Valaskovic, Kelleher, McLafferty Science (1996), 273, 1199 perfect zero-dead-volume

More information

Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12

Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12 XL Quilting Frame 1 Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12 Foot frame Printed 2 June 2014 Updated

More information

General Information. Ball Curb Valve

General Information. Ball Curb Valve General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)

More information

Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents

Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents Snap Tabs, etc. Stainless Steel Helmets Snap Tabs, Chin Strap, and Earphone Retainers Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel Contents SSBTM-1 1.1 Snap Tabs, Chin Strap, and

More information

Fully Automated Auto Scanning System VPD-ICPMS Expert

Fully Automated Auto Scanning System VPD-ICPMS Expert Fully Automated Auto Scanning System VPD-ICPMS Expert www.vpdicpms.com An indispensable tool for analysis of metallic impurities in Si wafer Developed in cooperation with Samsung Electronics Co., Ltd.

More information

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents Chin Strap Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets Contents BTM-1 1.1 Chin Strap BTM-4 1.2.3.1 Preparation BTM-1 1.1.1 Chin Strap Removal BTM-4 1.2.3.2 Disassembly BTM-1 BTM-2

More information

TOOLS AND INSTALLATION

TOOLS AND INSTALLATION TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and

More information

.red Chromatography Vials

.red Chromatography Vials Crimp top vials and caps Large opening vials with 11mm crimp neck finish Excellent for long term storage Clear vials made from Type I Class A and B glass (33/51 expansion) Requires crimper (and decapper)

More information

Technical Know-How Update

Technical Know-How Update Guidelines for Safe & Effective Use Introduction The MBX Bristle Blaster is a new, easy to use, hand-held surface preparation tool suitable for use on a variety of substrates including metals, rubbers

More information

PACKING LIST MACO V-5000

PACKING LIST MACO V-5000 PACKING LIST MACO V-5000 PART QTY O.D. SIZE LENGTH DESCRIPTION CHECKLIST T47P 4 5/8.050 36 Aluminum Tubing _ T43P 1 7/8.050 48 Aluminum Tubing _ T18P 1 3/4.050 48 Aluminum Tubing _ T15P 1 5/8.050 48 Aluminum

More information

DRAFT TANZANIA STANDARD MEDC 10(5692) P3 - SPECIFICATION FOR HONEY EXTRACTOR, RADIAL TYPE

DRAFT TANZANIA STANDARD MEDC 10(5692) P3 - SPECIFICATION FOR HONEY EXTRACTOR, RADIAL TYPE DRAFT TANZANIA STANDARD MEDC 10(5692) P3 - SPECIFICATION FOR HONEY EXTRACTOR, RADIAL TYPE TBS 2018 Draft Edition 1 0. FOREWORDS Honey extractors enable bee-keepers to extract the maximum quantity of honey

More information

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge International General Certificate of Secondary Education Cambridge International Examinations Cambridge International General Certificate of Secondary Education *9823048459* DESIGN AND TECHNOLOGY 0445/31 Paper 3 Resistant Materials October/November 2016 1 hour

More information

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove WARNING Read and understand all instructions before attempting to install any Victaulic piping products. These products must be used only on pipe that is prepared to Victaulic Advanced Groove System (AGS)

More information

Expert. Elemental Scientific VPD-ICPMS. Fully Automated Auto Scanning System ICP ICPMS AA

Expert. Elemental Scientific VPD-ICPMS. Fully Automated Auto Scanning System ICP ICPMS AA Expert VPD-ICPMS Fully Automated Auto Scanning System Elemental Scientific ICP ICPMS AA Expert Features An indispensable tool for the determination of metal impurities in Si wafer Expert automates routine

More information

Protractors / Clinometers / Spirit levels

Protractors / Clinometers / Spirit levels Protractors / Clinometers / Spirit levels Accuracy of clinometers/spirit levels according DIN 877 Graduation Flatness (µm) µm/m " (L = length in ) 50 10 4 + L / 250 > 50-200 > 10-40 8 + L / 125 > 200 >

More information

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge International General Certificate of Secondary Education www.xtremepapers.com Cambridge International Examinations Cambridge International General Certificate of Secondary Education *2587041388* DESIGN AND TECHNOLOGY 0445/33 Paper 3 Resistant Materials October/November

More information

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE The material included in this kit is to be used for WC styles of brakes that are designed or upgraded to the EP

More information

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

TNC SERIES General... 4 Interface... 5 Characteristics...6-7 CONTENTS PAGE TNC SERIES General... 4 Interface... 5 Characteristics...6-7 TNC 50 Ω SERIES Plugs...8-9 Jacks...0- Jacks and receptacles... Receptacles...-4 Adapters... 5 Caps... 6 TNC 75 Ω SERIES Plugs...

More information

Crimping Die Assemblies , , , , , , , , and 69653

Crimping Die Assemblies , , , , , , , , and 69653 Crimping Die Assemblies 46754-2, 46755-2, 46756-2, 46757-2, 46758-2, 46759-2, 46760-2, 59870-1, and 69653 Instruction Sheet 408-1602 10 NOV 16 Rev C 1. INTRODUCTION WIRE SIZE (MCM) (1) CMA (Circular Mil

More information

C-1650P 16 Gauge, 1/2 Medium Crown Stapler

C-1650P 16 Gauge, 1/2 Medium Crown Stapler C-1650P 16 Gauge, 1/2 Medium Crown Stapler MANUAL/WARNING: IMPORTANT PLEASE READ BEFORE USING TOOL Please read the following operating instructions manual. Refer to this manual for safety, adjustment and

More information

Radioisotope Shielded Work Station Components Models to

Radioisotope Shielded Work Station Components Models to Radioisotope Shielded Work Station Components Models 67-752 to 67-761! Provides optimum work conditions when using high energy nuclides! Offers maximum protection and versatility! Sold as separate components

More information

Tools and Tips: ( 1 )

Tools and Tips: ( 1 ) Tools and Tips: As you build instructions will show in my many picture manual how to assemble. You can use your own methods as you desire, my results are very good. A smooth, flat work surface is very

More information

Now available at participating Feeney (2/14) AF# A. Stores. 1/8'' Stainless Steel Cable Assemblies to Enhance Any Railing and Any View!

Now available at participating Feeney (2/14) AF# A. Stores. 1/8'' Stainless Steel Cable Assemblies to Enhance Any Railing and Any View! 2014 Feeney (2/14) AF# 2009-236A Now available at participating Stores 1/8'' Stainless Steel Cable Assemblies to Enhance Any Railing and Any View! Easy-to-install, prefabricated cable assemblies are an

More information

KAITE KWIK CHECK Rev.01

KAITE KWIK CHECK Rev.01 KAITE KWIK CHECK Rev.01 Rapid read hole measuring gauge for all industries. spray nozzle experts for the processing industry KAITE LTD elegance in design 2 KAITE KWIK CHECK Hole Gauge The KAITE KWIK CHECK

More information

C-1116LMA - Automatic Stapler w/ Long Mag

C-1116LMA - Automatic Stapler w/ Long Mag C-1116LMA - Automatic Stapler w/ Long Mag MANUAL/WARNING: IMPORTANT PLEASE READ BEFORE USING TOOL Please read the following operating instructions manual. Refer to this manual for safety, adjustment and

More information