1 LEDGON 100 Goniophotometer Two Global Leaders. One Complete Solution.

2 Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology that precisely measures the elements of color and light. Their products have become a staple in research and manufacturing environments, helping organizations to meet product quality and operational goals with less waste, time, and effort. This commitment to creating value for customers is the core principle behind the Konica Minolta brand, and has led them to develop the world s first portable spectrophotometer and the first light meter used on board a spacecraft (Apollo 8). It s also the driving force behind the high level of quality and precision built into each of their products. These are some of the reasons why Konica Minolta is regarded as the technological leader in color and light measurement solutions today. Based in Germany, Instrument Systems develops and produces high-quality optical test and measurement instruments for a broad spectrum of applications. Their extensive product range includes spectrometers, imaging photometers and colorimeters, goniophotometers, integrating spheres, and turnkey system solutions. Instrument Systems is dedicated to working with standardization committees and associations such as ICDM and CIE. They also cooperate with leading national metrology institutes. Now, these two experts have combined their knowledge and tools together to offer the complete solution for the most accurate measurement of light and color available in the market today.

3 Product Highlights Accurate determination of the luminous intensity distribution and luminous flux at LEDs and small LED modules Angular-resolved analysis of spectral and colorimetric quantities Type C configuration with motorized phi and theta axis Compatible with all spectrometers manufactured by Instrument Systems Data export in IES and EULUMDAT format The Goniometer Unit The fixed goniometer unit allows the test specimen to be rotated through two axes: the phi and the theta axis. The phi axis permits the specimen to be rotated through a full 360 in the mechanical axis of the test specimen, while the theta axis can be moved perpendicular to this in an angular range of +/ The angular accuracy is 1 for the phi axis and 0.1 for the theta axis. The compact LEDGON Goniophotometer was specially developed for analysis of angle-dependent spatial radiation patterns from individual LEDs and small LED modules. The entire hemisphere can be measured in the forward direction of the LED. The angular resolution of 0.1 means that exact measured values can be obtained even for narrow-angled LEDs with a high level of reproducibility. Combined with a spectroradiometer from Instrument Systems, all spectral parameters, for example color coordinates or color temperature can be measured as a function of angle. Particularly in the case of white LEDs, these parameters can undergo significant change depending on the observation angle. Knowledge of this characteristic property is extremely important for using white LEDs in illumination technology. Equipment Setup: Light-Tight Without Dark Room Goniometer unit The unit comprises a flat optical bench and a goniometer unit with two angular axes that is mounted at one end of the bench. One of the rotation stages has a hollow shaft where an LED test socket (any socket except LED-850) from Instrument Systems can be mounted. An optical probe is positioned at the other end of the optical bench allowing the distance to the LED to be set at between 5 and 50 cm. Two baffles can be variably positioned at any point to eliminate stray light. LEDGON connected to spectrometer Solid angle definition for phi and theta The entire setup is located in a light-tight enclosure with a folding lid which eliminates the need for a dark room. If larger measuring distances are required, an opening in the side wall of the LEDGON 100 also allows light to be measured from outside.

4 Options and Accessories An optional sample table (LEDGON-130) also permits measurement of LED arrays and small modules. This sample table can be upgraded with an XY translation stage (LEDGON-131) so that e.g. an LED module located off-center can be positioned in the center of rotation. Optical probe LEDGON-120 LEDGON 100 is compatible with all spectrometers suppliedby Instrument Systems. The CAS 140CT is ideal because it has a very large dynamic measuring range. This permits fully automated measurement of the radiation pattern, even for test specimens where the intensity varies significantly over the angle. Optional sample table LEDGON-130 Optical probes with diffusers (LEDGON-120 and LEDGON- 121), and an optical probe optimized for modules (LEDGON-125) can be supplied for measuring light radiation. The latter is based on a small integrating sphere that allows accurate measurements to be obtained also for test specimens radiating light from an extended surface. Control and Evaluation Functionalities with SpecWin Pro Software The LEDGON 100 is operated using SpecWin Pro Software from Instrument Systems. Two control modes are available: The sequence mode that allows the radiation pattern of the test specimen to be recorded for the two spatial axes (theta and phi) at equidistant angular increments. Parameters can be saved for subsequent evaluations. The test series mode, which permits free definition of test sequences, i.e. measurements at any definable sequences of angular positions. Other add-ons of SpecWin Pro software and appropriate instrumentation also permit current, voltage and temperature to be included in the goniometric analysis, as well as control and measured variables. For example, Keithley 2400 and Keithley 2600 sourcemeters can be easily installed as an add-on.

5 Accurate Measurements of Luminous Flux and Radiant Power The LEDGON 100 Goniophotometer is also ideal for precise measurement of radiant power and luminous flux. Potential measuring errors that can be caused by the geometry of integrating spheres are not encountered with goniometric measurement of luminous flux. Instrument Systems has developed an appropriate function for SpecWin Pro software that allows fully automated measurement. However, it should be noted that the angular range for the theta axis is ± 100 and hence a measurement is not possible in 4π. Display Options and Output Formats The graphics window used to visualize the measurements is the central element of the user interface in the goniometer mode of SpecWin Pro. Five different displays are available for the radiation pattern: a radial, a semiradial and a cartesian view, a two-dimensional spherical display, and a 3-D view. Display of the luminous intensity distribution curve is also important for general lighting. The measured data can be exported in the IES and EULUMDAT format for use in simulation programs. SpecWin Pro 3D radiation pattern Semi-radial display of the luminous intensity distribution curve

6 Contact information Instrument Systems - Operating Globally, Acting Locally Instrument Systems is the premier company for light measurement. As a subsidiary company of Konica Minolta we have access to resources over the long term and to a global network our mission is your solution, anytime and anywhere. World-class customer support is rewarded with customer loyalty - a top priority at Instrument Systems. Neumarkter Str. 83 D München, Germany Phone: +49 (089) Fax: +49 (089) webinfo@instrumentsystems.com Konica Minolta Sensing Americas Konica Minolta Sensing, Americas represents Instrument Systems in North America and Canada with a high level of expertise in marketing optical measuring instruments. High-quality customer support is based on a track record of close cooperation and constant exchange of information and know-how. 101 Williams Drive Ramsey, NJ USA Phone: Toll Free: Fax: marketing.sus@konicaminolta.com sensing.konicaminolta.us

7 Ordering Information Order Number LEDGON-100 LEDGON-105 LEDGON-120 LEDGON-121 LEDGON-124 LEDGON-125 LEDGON-130 LEDGON-131 LEDGON-135 Description Goniometer for LEDs and small LED modules; light-tight setup with optical bench (without measuring head); includes stepper motor controller Slit at the side panel of the LEDGON for fiber cable gland Measuring head with diffuser (1 cm² area); incl. OFG-414 fiber bundle and PLG-410 fiber plug adapter; spectral range nm Measuring head with diffuser (1 cm² area); incl. OFG-424 quartz fiber bundle and PLG-420 fiber plug adapter; spectral range nm Rail carrier for mounting the LED integrating sphere in the LEDGON Complete measuring head comprising ISP25 integrating sphere with 1 cm² measurement aperture, rail carrier LEDGON-124, OFG-424 and PLG-420; spectral range nm Sample table for LED modules and mini displays XY translation stage for assembly on the LEDGON-130 sample table Alignment laser for optical bench in the LEDGON Instrument Systems is continually working to develop and improve products. Any technical changes, errors or misprints do not form grounds for compensation. The company`s Terms of Delivery and Payment apply in all other respects. Technical Specifications LEDGON Goniophotometer LEDGON-100 basic unit Angular range Theta axis : approx. +/- 100 ; phi axis: 360 Angular accuracy Theta axis : 0.1 ; phi axis: 1 LEDGON-130 sample table Clamping distance 2 x 15 mm Sample dimension max. 112 x 112 x 48 mm (W x L x H) Maximum sample weight 700 g Voltage supply 10 x 0.1 mm² max. 1A; 2 x 0.75 mm² max. 6A LEDGON-131 XY translation stage Travel range 49 mm per axis Sample dimension max. 64 x 85 x 25 mm (W x L x H) In the interest of the continuous development and improvement of our products, we reserve all rights to make technical changes to the information contained in our printed material. Such changes, errata and printing mistakes do not constitute grounds for claims for damages. The LumiCam series of measurement cameras may only be used for luminance and chromaticity measurements of self-illuminating objects. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Certificate No : LRQ A Registration Date : March 3, 1995 Certificate No : JQA-E Registration Date : March 12, 1997

External Optical Probes. EOP-xxx and ISP 40. Two Global Leaders. One Complete Solution.

External Optical Probes. EOP-xxx and ISP 40. Two Global Leaders. One Complete Solution. External Optical Probes EOP-xxx and ISP 40 Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology

More information

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution. TOP 200 Telescopic Optical Probe for Radiance and Luminance Measurements Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas

More information

SpecWin Pro. Spectral Analysis Software. Two Global Leaders. One Complete Solution.

SpecWin Pro. Spectral Analysis Software. Two Global Leaders. One Complete Solution. SpecWin Pro Spectral Analysis Software Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology

More information

LED 81x. Test Sockets for High-Power LEDs. Two Global Leaders. One Complete Solution.

LED 81x. Test Sockets for High-Power LEDs. Two Global Leaders. One Complete Solution. LED 81x Test Sockets for High-Power LEDs Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology

More information

LGS Goniophotometer. Two Global Leaders. One Complete Solution.

LGS Goniophotometer. Two Global Leaders. One Complete Solution. LGS 1000 Goniophotometer Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology that precisely

More information

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution. CAS 120 CCD Array Spectrometer Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology that

More information

We bring quality to light. MAS 40 Mini-Array Spectrometer

We bring quality to light. MAS 40 Mini-Array Spectrometer MAS 40 Mini-Array Spectrometer Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters Different models

More information

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT WE BRING QUALITY TO LIGHT DTS 500 Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT Standalone XYZ positioners (260 to 560 mm max. travel range) Standalone 2-axis goniometers (up to 70 cm diagonal

More information

We bring quality to light. CAS 120 CCD Array Spectrometer

We bring quality to light. CAS 120 CCD Array Spectrometer We bring quality to light. CAS 120 CCD Array Spectrometer The features at a glance Precision spectrograph with integrated density filter wheel (OD 1 4) Shutter for automatic dark current correction 2048

More information

Excellent light measurement technology

Excellent light measurement technology PRODUCTS & SOLUTIONS Excellent light measurement technology Working together for a perfect solution! Are you looking for a partner in light measurement technology who can offer you not only firstclass

More information

Imaging Photometer and Colorimeter

Imaging Photometer and Colorimeter W E B R I N G Q U A L I T Y T O L I G H T. /XPL&DP Imaging Photometer and Colorimeter Two models available (photometer and colorimetry camera) 1280 x 1000 pixels resolution Measuring range 0.02 to 200,000

More information

We bring quality to light. CAS 140CT Array Spectrometer

We bring quality to light. CAS 140CT Array Spectrometer We bring quality to light. CAS 140CT Array Spectrometer light measurement accuracy and reliability LED measurement display measurement spectral measurement specifications Features at a glance Available

More information

LED Tester BTS256-LED

LED Tester BTS256-LED 1 LED Tester BTS256-LED The BTS256-LED tester is one of the most compact light measurement devices with integrated integrating sphere for high accuracy measurement of luminous flux, spectral and color

More information

We bring quality to light. Spectro 320 Scanning Spectrometer

We bring quality to light. Spectro 320 Scanning Spectrometer We bring quality to light. Spectro 320 Scanning Spectrometer light measurement Instrument description Applications Spectroradiometry NVIS Display measurements Specifications Key features at a glance Fast-Scan

More information

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Luminaire Goniophotometer (C-γ, B-ß Plane ) The BGS400 moving lamp and luminaire gonio-photometer is an economical, turnkey solution for

More information

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light. CAS 140D Array spectrometer for high accuracy light measurement We bring quality to light. Key features at a glance y High-end CCD detector, cooled and back-illuminated y Down to 4 ms integration time

More information

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light.

CAS 140D. Array spectrometer for high accuracy light measurement. We bring quality to light. CAS 140D Array spectrometer for high accuracy light measurement We bring quality to light. Key features at a glance y High-end CCD detector, cooled and back-illuminated y Down to 4 ms integration time

More information

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER Presented by: January, 2015 1 NFMS THEORY AND OVERVIEW Contents Light and Color Theory Light, Spectral Power Distributions, and

More information

LED Tester BTS256-LED

LED Tester BTS256-LED 1 LED Tester BTS256-LED The BTS256-LED tester is one of the most compact light measurement devices with integrated integrating sphere for high accuracy measurement of luminous flux, spectral and color

More information

Novel Approach for LED Luminous Intensity Measurement

Novel Approach for LED Luminous Intensity Measurement Novel Approach for LED Luminous Intensity Measurement Ron Rykowski Hubert Kostal, Ph.D. * Radiant Imaging, Inc., 15321 Main Street NE, Duvall, WA, 98019 ABSTRACT Light emitting diodes (LEDs) are being

More information

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter Technical Overview Functionality Applications Specifications Key features at a glance Three models: Mono, Color, Advanced 1370 x 1020

More information

Application Note (A16)

Application Note (A16) Application Note (A16) Eliminating LED Measurement Errors Revision: A December 2001 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com

More information

Chameleon Spectroradiometer

Chameleon Spectroradiometer Chameleon Spectroradiometer SPEED / STABILITY / ACCURACY The Chameleon Series is designed to measure the absolute spectral of power, of the light under test. Adding optical probes and absolute calibration

More information

Spectrophotometer CM-3630 PaperControl Software

Spectrophotometer CM-3630 PaperControl Software The missing link to total quality Solutions made to measure the paper industries needs. Introducing Konica Minolta s high-efficiency ISO solution for precise whiteness and color measurement Spectrophotometer

More information

JETI Specbos Instruments

JETI Specbos Instruments Spectral measuring instruments for various applications JETI Specbos Instruments The new Specbos family offers compact, spectrometric instruments, designed to measure the color coordinates, spectral characteristics

More information

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers New Auto Mode increases accuracy at low luminance levels CHROMA METER CS-200 Suitable for measurement of optical devices such as LCDs, PDPs, organic ELs, FEDs and LEDs. 1.0 0.5 380 400 500 600 700 (nm)

More information

SPECTRAL SCANNER. Recycling

SPECTRAL SCANNER. Recycling SPECTRAL SCANNER The Spectral Scanner, produced on an original project of DV s.r.l., is an instrument to acquire with extreme simplicity the spectral distribution of the different wavelengths (spectral

More information

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings. Understanding Color Rendering Index Introduction The LED lighting market has experienced rapid growth in recent years as people are becoming more aware of their benefits. While CFLs remain the choice for

More information

Luminous Flux (lumens) System LM-ISP-XXXX

Luminous Flux (lumens) System LM-ISP-XXXX Company Profile Taiwan Optimum Optoelectrics Co., Ltd. is Taiwan's the first of photometric and colorimetric measurement equipments and professional supplier of calibration services in Taiwan. In particular,

More information

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting Ideal for measuring color temperature NEW Chroma Meter CL-200A Even measures new light sources such as LED lighting and organic EL lighting A compact, lightweight instrument with a detachable receptor.

More information

LED Lighting Flux and Color Measurement System (LFC)

LED Lighting Flux and Color Measurement System (LFC) LED Lighting Flux and Color Measurement System (LFC) Fast, accurate and complete System for research and production LFC System is a high cost efficiency light measurement system. The system is designed

More information

Broadbandradiometer specbos 1211

Broadbandradiometer specbos 1211 Broadbandradiometer specbos 1211 specbos 1211 is a broadband and fast spectroradiometer which can be used in laboratory as well as production environment to measure the following quantities: Luminance,

More information

Spectroradiometer specbos 1201

Spectroradiometer specbos 1201 Spectroradiometer specbos 1201 specbos 1201 is a precise and compact VIS spectroradiometer. It can be used in laboratory as well as production environment to measure the following quantities: Luminance,

More information

Miniaturized Spectroradiometer

Miniaturized Spectroradiometer Miniaturized Spectroradiometer Thomas Morgenstern, Gudrun Bornhoeft, Steffen Goerlich JETI Technische Instrumente GmbH, Jena, Germany Abstract This paper describes the basics of spectroradiometric instruments

More information

Fully Portable Spectrophotometer for Transmission Measurement

Fully Portable Spectrophotometer for Transmission Measurement November 2008 LCRT-2005-S Portable Spectrophotometer for Transmission Measurement Spectral Transmission in d/0 and 0/0 Measurement Geometries Transparency Measurement in real in-line Set-up Photometric

More information

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. Spectroradiometer CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. 15 World's top level capability to detect extremely low

More information

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna High Accuracy Spherical Near-Field Measurements On a Stationary Antenna Greg Hindman, Hulean Tyler Nearfield Systems Inc. 19730 Magellan Drive Torrance, CA 90502 ABSTRACT Most conventional spherical near-field

More information

Illuminance Meter. series

Illuminance Meter. series Compatible with PWM-controlled sources New series Illuminance meters that conform to JIS AA Class and DIN Class B requirements. Compatible with new, next-generation light sources including PWM-controlled

More information

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications System Options AC Susceptibility Magnetic Property Measurement System Many materials display dissipative mechanisms when exposed to an oscillating magnetic field, and their susceptibility is described

More information

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement

More information

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs Jeffrey L. Guttman, John M. Fleischer, and Allen M. Cary Photon, Inc. 6860 Santa Teresa Blvd., San Jose,

More information

INTERFEROMETER VI-direct

INTERFEROMETER VI-direct Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production

More information

robogonio Quick. Precise. Highly flexible.

robogonio Quick. Precise. Highly flexible. robogonio Quick. Precise. Highly flexible. www.robogonio.com One system, six good reasons What the robogonio can do. Measurements with the robogonio at a glance Everything is possible. 1. Highest flexibility

More information

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Rotation By: Michael Case and Roy Grayzel, Acton Research Corporation Introduction The majority of modern spectrographs and scanning

More information

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM Goniophotometer / Integrating Sphere/ Spectroradiometer/ Illuminance Meter Luminance Meter / UV Radiometer Benefits Easy to Use High End Product Precise Measurement

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1

More information

LIMES 2000 Release Notes

LIMES 2000 Release Notes Page 1 of 8 These release notes are describing changes in LIMES 2000 since version 16.0607.806. A number of topics with regard to measurements of automotive lighting devices are covered, the latter mainly

More information

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting. https://www.gigahertz-optik.de/en-us/product/bts256-par

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting. https://www.gigahertz-optik.de/en-us/product/bts256-par BTS256-PAR https://www.gigahertz-optik.de/en-us/product/bts256-par Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting Gigahertz-Optik GmbH 1/8 Description Measurement and examination of

More information

LightSpion. User guide. Last edited: Patent pending

LightSpion. User guide. Last edited: Patent pending LightSpion User guide Patent pending Last edited: 2013-05-27 Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without

More information

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum. Page 1 BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum. The BTS256-E WiFi is a high-quality light meter

More information

IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS

IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS Matt Scholz, Radiant Vision Systems February 21, 2017 Matt.Scholz@RadiantVS.com 1 TODAY S SPEAKER Matt Scholz Business Leader, Automotive

More information

1/8 m GRATING MONOCHROMATOR

1/8 m GRATING MONOCHROMATOR 1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser. BTS2048-BS http://www.gigahertz-optik.de/en-us/product/bts2048-bs Product tags: VIS, Spectral Data, Industrial Applications, Laser Gigahertz-Optik GmbH 1/6 Description BTS2048-BS CCD spectroradiometer

More information

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. Spectroradiometer /000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low luminance

More information

Instruction Manual of Luminance and Spectral Radiance Calibrations

Instruction Manual of Luminance and Spectral Radiance Calibrations Aalto University School of Electrical Engineering Metrology Research Institute Jari Hovila Pasi Manninen Tuomas Poikonen Petri Kärhä Instruction Manual of Luminance and Version 2.6 07/12/2015 Page 2 (19)

More information

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System Look for your photometricsolutions.com Page 1 of 6 Photometric Solutions International Pty Ltd ABN 34 106

More information

Improving the Collection Efficiency of Raman Scattering

Improving the Collection Efficiency of Raman Scattering PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution

More information

Company synopsis. Regulations and Standards

Company synopsis. Regulations and Standards Goniophotometer Company synopsis Pleiades Instruments is an optoelectronic system maker, designing and manufacturing for you specific systems such as photometric measurement and customized systems. Designing

More information

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014 IESNA LM-79: 2008 Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE Dec 08, 2014 Product Name: LED Model No: 82031 Test Engineer: David Zhang Report No.: BTR66.181.14.0039.06

More information

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5 ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other

More information

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold 1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance

More information

MICRO SPECTRAL SCANNER

MICRO SPECTRAL SCANNER MICRO SPECTRAL SCANNER The OEM μspectral Scanner is a components kit that can be interfaced to existing microscope ready to accept cameras with Cmount to obtain an hyper-spectral imaging system. With OEM

More information

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv BTS2048-UV https://www.gigahertz-optik.de/en-us/product/bts2048-uv Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED Gigahertz-Optik GmbH 1/8 Description UV CCD spectroradiometer

More information

Development of 2 Total Spectral Radiant Flux Standards at NIST

Development of 2 Total Spectral Radiant Flux Standards at NIST CIE/USA Annual Conference, October 7, 2014, Seattle, WA Development of 2 Total Spectral Radiant Flux Standards at NIST Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland Outline

More information

Photometry and Light Measurement

Photometry and Light Measurement Photometry and Light Measurement Adrian Waltho, Analytik Ltd adrian.waltho@analytik.co.uk What is Light? What is Light? What is Light? Ultraviolet Light UV-C 180-280 nm UV-B 280-315 nm UV-A 315-400 nm

More information

GL spectis 1.0 Touch The world s first smart spectrometer.

GL spectis 1.0 Touch The world s first smart spectrometer. TM Touch the technology GL spectis 1.0 Touch The world s first smart spectrometer. Enter the world of smart spectrometers GL Optic offers a complete line of measuring instruments using the latest smart

More information

Achieving 100,000 : 1 contrast measurement

Achieving 100,000 : 1 contrast measurement NEW Spectroradiometer Highly precise spectral radiance/chromaticity measurement possible from 0.003 cd/m 2 Achieving 100,000 : 1 contrast measurement World's top level capability to detect extremely low

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The

More information

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30

More information

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION John Demas Nearfield Systems Inc. 1330 E. 223rd Street Bldg. 524 Carson, CA 90745 USA

More information

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control SPECTROPHOTOMETER CM-2600d Simply expands the Boundaries in Color Control 31 PRONOUNCING SPECTROPHOTOMETER IS THE ONLY COMPLICATED THING ABOUT OUR LATEST PRODUCT. We don t need to explain to you how important

More information

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET REPLACE NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET 9925 Carroll Canyon Road San Diego, CA 92131 (800) 637-2758 (858) 279-8034 Fax (858) 576-9286 www.gamma-sci.com About Gamma Scientific:

More information

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA. IESNA LM-79: 2008 Measurement and Test Report for Jiawei Technology (USA) Limited 2305 Lincoln Ave.Hayward, CA 94545 USA Apr 03, 2015 Product Name: self-ballast LED Lamp Model No: DL-9PAR30-830-LN-25-D;ML-9PAR30-830-LN-25-D

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

LEADING THE WAY in Light Measurement Systems

LEADING THE WAY in Light Measurement Systems LEADING THE WAY in Light Measurement Systems LIGHT MEASUREMENT SYSTEMS THERMAL CONTROL SYSTEMS WIDE DYNAMIC RANGE SPECTROMETERS www.labsphere.com/illumia SOLUTION BASED PROFESSIONAL SOFTWARE Welcome to

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SRTGLEDGI SRTGLEDGI 15W 30K WD E1 GES66 15W 30KRated Voltage: Watts 15 watt Driver Type: Roal Strato GE RSLD035-7A Infusion M1000/83 Rated CCT: Orientation VBU GE Infusion M1000/830/W/N

More information

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0. Total Integrated Radiant Flux Total Integrated Luminous Flux Luminous Efficacy Peak Wavelength Dominant Wavelength Color Purity CCT CRI Ra Peak Candela Irradiance (W/m 2 *nm) Figure 3 Spectral Illuminance

More information

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications System Options AC Susceptibility Magnetic Property Measurement System Many materials display dissipative mechanisms when exposed to an oscillating magnetic field, and their susceptibility is described

More information

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SGE4SQLEDGI SGE4SQLEDGI 30W 30K ND E1 AR0204LGI 30W 3SG Rated FGCC Voltage: Watts 30 watt Driver Type: Roal Strato GE RSLD035-07 Infusion M2000/83 Rated CCT: Orientation VBU

More information

Microscope-Spectrometer

Microscope-Spectrometer 20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments

More information

Oriel Cornerstone 130 1/8 m Monochromator

Oriel Cornerstone 130 1/8 m Monochromator 1 Oriel Cornerstone 130 1/8 m Monochromator Cornerstone 130 1/8 m Monochromator The Cornerstone 130 family of Oriel Monochromators supports two gratings simultaneously, which can be easily interchanged,

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc. High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure Global Office of Lisun Electronics Inc. http://www.lisungroup.com Lisun Group (Hong Kong) Limited Add: Room

More information

Solid State Luminance Standards

Solid State Luminance Standards Solid State Luminance Standards Color and luminance correction of: - Imaging colorimeters - Luminance meters - Imaging spectrometers Compact and Robust for Production Environments Correct for instrument

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China, 519085 LED Linear Ambient Light Model Name(s):

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative

More information

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104 1 RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104 Abstract The TM6102, TM6103, and TM6104 accurately measure the optical characteristics of laser displays (characteristics

More information

LG-2.0. Mirror Goniophotometer. Look for your photometricsolutions.com

LG-2.0. Mirror Goniophotometer. Look for your photometricsolutions.com LG-2.0 Mirror Goniophotometer Theory of Operation A goniophotometer (also called a distribution photometer) is a device for measuring the luminous intensity distribution of luminaires. In other words,

More information

Radial Polarization Converter With LC Driver USER MANUAL

Radial Polarization Converter With LC Driver USER MANUAL ARCoptix Radial Polarization Converter With LC Driver USER MANUAL Arcoptix S.A Ch. Trois-portes 18 2000 Neuchâtel Switzerland Mail: info@arcoptix.com Tel: ++41 32 731 04 66 Principle of the radial polarization

More information

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 - metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 - ACTINIC FLUX SPECTRAL RADIOMETERS Ultra-fast CCD-Detector Spectrometer, UVB enhanced Cooled CCD, 512 pixel *

More information

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands The Art of Light Measurement Avantes BV Apeldoorn, The Netherlands Who am I? Ger Loop Product Manager Avantes BV Oude Apeldoornseweg 28 7333 NS APELDOORN The Netherlands Phone: (+31) 313 670170 Fax: (+31)

More information

Report No.: EASZE Page 2 of 14

Report No.: EASZE Page 2 of 14 Report No.: EASZE03220005 Page 2 of 14 1 SUMMARY Parameter Result Total Luminous Flux 1680.9 lm Luminous Efficacy 83.34 lm/w Power Factor 0.9829 Color Rendering Index (Ra) 83.7 Correlated Color Temperature

More information

CS-2000/2000A. Spectroradiometer NEW

CS-2000/2000A. Spectroradiometer NEW Spectroradiometer NEW CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low

More information

SPECTROPHOTOMETER CM-2600d

SPECTROPHOTOMETER CM-2600d SPECTROPHOTOMETER CM-2600d Simply expands the Boundaries in Color Control PRONOUNCING SPECTROPHOTOMETER IS THE ONLY COMPLICATED THING ABOUT OUR LATEST PRODUCT. We don t need to explain to you how important

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information