Digital Tachometer. TM-3100 series. Introducing a new digital tachometer with a clear display and ability to add functions separately and easily!

Size: px
Start display at page:

Download "Digital Tachometer. TM-3100 series. Introducing a new digital tachometer with a clear display and ability to add functions separately and easily!"

Transcription

1 Digital Tachometer TM-00 series Customize your tachometer with added function, which matches your own application. Highly compatible with personal computers and controllers. Provided with wide variety of determination functions. All models are applicable to CE marking. Line speed Moving speed Period Counter Frequency Flow Standard measurement functions Introducing a new digital tachometer with a clear display and ability to add functions separately and easily! Passing time Rotation change rate Acceleration Reached speed time Optional functions Section data memory

2 The best solution proposed by Ono Sokki Choose the functions, customize the tachometer It becomes more easier easily to use! to use! New tachometer is finding applications in many different fields! Feature Previous Models (TM-00 series) Feature Choose functions to match your application. Display only Display with BCD Several tachometers were needed for each required application and function. Fluorescent display tube greatly improves readability. Setting with bit switch Choose model to match your application Applications Display with analog Display with comparator Only adding the required function (card) to one tachometer according to application and function. As measurement becomes more diverse, it is not easy to select a suitable model that meets your application. Measuring requirements are often changed or added. The TM-00 series enables you to respond instantly to changes in these diverse needs by adding functions to match the application. Customer s Benefits Custom-tailor rotation measurement to match your application by adding functions. Previous Models (TM-00 series) Setting with bit and rotary switches 7-segment characters are not read easily. LED New Models (TM-00 series) New Models (TM-00 series) Add functions to match your application TM-0 Display only TM-0 Display with BCD TM-0 Display with analog TM-0 Display with comparator Change or addition of measurement needs Add functions by the optional cards Recognized clearly, read easily Fluorescent display Character is recognized and read easily and clearly in menu screen. Read the rotation speed (number of rotations) directly Attaching an exclusive -mm square reflective mark to a shaft of motor or other rotating axis, non-contact rotation speed measurement by using a photoelectric detector is performed. Motor Reflective mark TM-0 Digital tachometer LG-900 Photoelectric detector AX-00N Output the rotation speed to a recorder Setting the rotation detector closely to the teeth of the detection gear which is connected to the main rotating shaft of an agitator, mixer, centrifuge or the like, you can measure and display the shaft s rotation speed as well as record and view changes in rotation on a recorder or the like using analog. MP-00 Detection gear Agitator TM-0 Digital tachometer MP-98 Magneto-electric rotation detector AX-00N Analog Recorder Output the measurement results to a printer or a PLC* Measure and display the rotation speed of a motor or other shaft, while using the BCD function of the TM-0 to send the measurement results to a printer or load them into a PLC. You can also calculate and display the rotation speed of the gear-b shaft by setting the number of teeth on gear-a divided by the number on gear-b (0/80 = 0.00) at TM-0. MP-98 Magneto-electric detector TM-0 Digital tachometer BCD cable MP-00 Detection gear * Programmable Logic Controller AX-00N The number of A-gear teeth =0 The number of B-gear teeth=80 RQ-0 Digital Printer Monitor the line speed Measuring and displaying the line speed of a belt conveyor or the like in the unit of m/min, alarm signal will be when it exceeds the setup speed or stop any operated machine itself by using comparator. The display of the TM-00 series can be set to show a decimal (up to three decimal places); enabling you to display decimal values (e.g. XXXX.X or XXX.XX). TM-0 Digital tachometer Comparator AX-00N RP-08 ( meter) RP-700 series Roller Encoder (0 or 00 P/R) PLC Lower OK Upper Upper-/lower limit determination Even with setting procedures in menu screen, a user's manual is sometimes needed just in order to read the characters correctly. (Example: ABCD.EI) Unit of measurement can also be selected in menu screen. The unit of measurement is shown on the fluorescent display. No more need to attach labels of the measuring unit at the front panel of the tachometer! The TM-00 series uses a fluorescent display tube, maintaining display durability while greatly improving readability. Customer s Benefits. Greatly improved readability of the characters reduces errors when setting function.. Operating procedure becomes improved, which helps reducing the setup time because the function can be setup in menu screen. If the surface of the rotating shaft has irregularities or a black line, the amount of reflected light received by the optical fiber detector will vary periodically. These periodic variations are used to measure the rotation speed. This allows measurement of very small shaft where it is not feasible to affix a reflective mark as well as fan motor and the like where light is not reflected back directly. This series (except TM-0) can also communicate with a computer by adding TM-00 (RS-C card). This also facilitates data management. Control from a computer via RS-C FG-00 Optical Multimeter Detecting range: Approx. to 0 mm TM-0 Digital tachometer (added TM-00) MX-00 series RS-C FS-00 Optical Fiber sensor with fiber cable DC Motor * Suitable rotation shaft diameter: mm or more AX-00N Comparator Personal computer Upper-/lower limit determination

3 Add more functions to the TM-00 series by the optional cards! TM-0 Rotation-display model Smooth replacement of previous models (TM-00 series) with the TM-00 series! Calculation function (Common to all models), line speed (circumferential speed), moving speed, period, frequency, passing time, times (/s), flow Auto zero function Rapid deceleration follow-up function Moving average function Peak-hold function TM-0 Display with analog Basic model for measurement and display. Wide range of measurement from low to high rotation. (0. Hz to 00 khz) Output signal can be selectable from voltage or current. D/A conversion allows improving its refresh time (0 ms). TM-0 Display with BCD BCD with -digit Open collector for direct connection with a PLC*. Output mode is selectable from normal or request mode. Normal mode: Continuously the print command at every approx. s. Request mode: Output the data by the external each request signal. Voltage function is available by modification as an option. All models are applicable to CE marking. Up to three combinations of the determination levels at each upper-/lower limit can be setup. Output refresh time with high-speed response at approx. 0 ms Equipped with wide variety of functions TM-0 Display with comparator * Programmable Logic Controller TM-0/0/0/0 Common specifications Input Input terminal M free terminal screw Input impedance 0 kω or more Input format Voltage or non-voltage input Input amplification AC or DC format Applicable detector Electromagnetic/magneto-electric /photoelectric detector, rotary encoder, proximity switch [Specifications of input amplification] AC amplifier Signal waveform Sine or Square waveform Signal voltage range Sine waveform: 0. to Vrms Square waveform: 0. to Vp-p Signal frequency range Hz to 00 khz DC amplifier Signal waveform Square waveform having a pulse width at µs or more. Signal voltage range Hi level: + to +0 V Lo level: - to + V Signal frequency range 0. Hz to 00 khz Low pass filter Selectable from OFF, 0 khz Output <Pulse > Output voltage Hi level: +. V or more Lo level: +0. V or less Output logic Negative logic Load resistance 00 kω or more Output terminal M free terminal screw Display Display device Fluorescent display tube (selectable of three-stage brightness, -digit display) Display refresh time Selectable from 0. s (factory setting), 0. s, 0. s, 0. s, 0.8 s,.0 s to 0 s (in.0 s step) Unit of measurement Selectable from below Measurement item Unit r/s, r/min, r/h Circumferential speed mm/s, m/s, mm/min, m/min Moving speed mm/s, m/s, mm/min, m/min, km/min, mm/h, m/h, km/h Period s, min s (/s) /s, /min, /h Frequency Hz, khz Flow ml/s, ml/min, ml/h, l/s, l/min, l/h Passing time s, min User-defined EU/s, EU/min, EU/h (Engineering unit) Number of decimal Selectable from OFF (factory setting), number of decimal points point of, or digit SIG indicator Blink in synchronization with input signal Error display Backup memory error, board error, input frequency error, display digit error, memory full error, setup value error Calculation Calculation display, circumferential speed, moving speed, period, times (/s), frequency, flow, passing time Measurement method Periodic calculation method Calculation time 0 ms + period time Measurement accuracy Display value (±0.0 %) within ±count * The display value indicates the count value except the decimal point. Auto zero function The display value becomes zero with no signal input for the setup time in advance. Selectable from below: OFF ( s), 0. s,.0 s,.0 s,.0 s,.0 s,.0 s,.0 s, 7.0 s, 8.0 s, 9.0 s, 0.0 s Rapid deceleration If an input signal rapidly decreases and there is no follow-up function signal input to tachometer approx. second or more, measurement automatically decelerates with this function and then zeroed in approx. seconds later. Moving average Selectable from below: function OFF (factory setting),,, 8,,,, 8 *Analog by TM-0/00 is obtained by the processing of moving average with the calculation at every 0 ms. Peak-hold function Hold the peak value (maximum, minimum, average) between start and stop status. Memory Panel condition Memorize kinds of measurement conditions. memory Setup conditions can be stored and recalled. Power supply for detector Output voltage VDC ±0 % Maximum 00 ma current General specifications Power rating 00 to 0 VAC (0 Hz/0 Hz) 0 VA max. to 9 VA (TM-0) to VA (TM-0) to VA (TM-0) to VA (TM-0) (0 to 0 VA when analog, BCD and comparator cards are equipped) 00 VAC (min) Withstand voltage Insulation resistance 0 MΩ or more (at 00 VDC by megohmmeter) Operating temperature / humidity range 0 to +0 ºC / 0 to 80 % RH (with no condensation) Storage temperature / humidity range -0 to +0 ºC / 0 to 8 % RH (with no condensation) Outer dimensions 9(W) 8(H) 8(D)mm Weight Approx. 0 g Applicable standard CE marking Low Voltage Directive EN00-:00(nd) Overvoltage Category II/ Pollution Degree EMC (Electromagnetic Compatibility) Directive EN-: 00 Embedded board Accessories Manual Specification copy Basic Operation copy Panel mounting fixtures set Condenser to prevent chattering set * A power cable (AX-00N): sold separately

4 Specifications for TM-0/0/0 and optional cards Model name TM-0 TM-0 (BCD Voltage card) TM-0 (BCD open collector card) TM-0 TM-00 (Analog card) TM-0 TM-00 (Comparator card) TM-00 (RS-C/gate card) TM-00 (DC power operated card) Specifications TM-0/0 TM-0 Output signal TM-0 card s BCD as voltage. Operation is same as Output form : -digit parallel TM-0 (BCD-open collector). Output format : Open collector Output signal Sink current : ma max. Output format : The open collector is pulled up to + V with a Output withstand : V max. 0 kω resistor in the internal circuit of the voltage voltage of TM-0. Output logic : Positive logic Data refresh time : 00ms or less Input signal (request signal) Input logic : Negative logic (with pulse width at 0 µs or more) Operating edge : Falling edge Input voltage : TTL Output mode Mode selector : Selectable from normal mode or request mode Output signal Output method Linearity : ±0. %/F.S. Output function UPPER,LOWER,OK,ERROR s * It s OK signal when both UPPER and LOWER s are OFF. * It s ERROR signal when comparator has an abnormal operation. Setup UPPER setup : -digit numeric input The relay is when UPPER < = displayed value. LOWER setup : -digit numeric input The relay is when LOWER > displayed value. Output specification Format : -make contact * Three kinds of s (COMP, COMP and COMP) are independently. (UPPER, LOWER, OK, ERROR for each combination of s.) Ex.) COMP=LOWER, COMP=UPPER, COMP=ERROR Maximum contact capacity : 0 VDC/ A, 0 VAC/ A Output refresh time : Approx. 0 ms Output adjustment : Voltage ; ± %/F.S. or more Current ; ± %/F.S. or more Setup accuracy : Voltage ; ZERO±0. %/F.S. FULL±0. %/F.S. Current ; ZERO±0. %/F.S. FULL±0.7 %/F.S. Zero drift : ±0.0 %/F.S./ºC Span drift : ±0.0 %/F.S./ºC Output refresh time : Selectable from followings; 0, 0, 0, 00, 00, 00 ms, s Input specification : Reset level to be contact OFF. Other usable function Automatic recover : The comparator automatically recovers when the rotation speed falls under the setup level again after that the state of contact is at OK/UPPER/LOWER. * The rotation speed of recovery can be changed by using hysteresis function. Output hold Shot TM-00 is an optional card which allows using of DC power. Power voltage : to VDC± % Power rating : TM-0/0/0; Approx. 7 VA, TM-0; Approx. 9 VA *Power rating is approx. VA when analog, BCD and comparator cards are equipped. Delay Setup range ; to ±0 %, can be setup in % step. : It can hold the state of contact unless the reset signal is input. : The time of holding the contact (shot time) can be changed. The state will automatically recover after the holding time. Setup range ; 0 to 000 ms in 0 ms steps : The state will be contact when the rotation speed exceeds continuously for the setup time or more in advance. *Setup range: 0 to 000 ms in 0 ms steps TM-00 allows RS-C communication and gate control. New calculation functions below also can be added in order to respond to higher performance of application. RS-C Communication method : Serial communication (asynchronous) Baud rate : Selectable from 900 bps or 900 bps Gate function Control function Calculation function Rotation change rate Section data memory function : Start, stop and reset : Change value against reference value is calculated for each measurement item. (rotation speed, circumferential speed, moving speed, period, passing time, number of times, flow). * Reference value ; Section average value or user setup ( to numeric input) Measurement accuracy ; [±0.0 % x maximum section variation± counts] / [±0.0 % x reference value± count] * Maximum section variation= (Maximum or minimum value in measurement section whichever having a larger difference from reference value)-reference value : Calculate and store the average, maximum, minimum values and section change rate in setup time at every section. Section time; Selectable from s, s, 0 s, 0 s, min, min, 0 min, 0 min, 0 min Maximum number of sections; 8 sections Memory mode; Ring buffer mode or memory full mode *Ring buffer mode ; Delete section memory in order of the oldest one and continue to store the latest section data when number of section data exceeds 8. *Memory full mode ; The storing of the data will be completed after the data for 8 sections are stored. Acceleration calculation function Display unit; rad/s, r/s, m/s Measurement accuracy; ±0.0 % x VDEF ± counts Reached speed time function Control connector : Selectable from voltage or current : bit D/A conversion However, the resolution may decrease depending on the setup value. Output range : Voltage range ; Selectable from followings; 0 to 0 V, 0 to V, to V Current range ; to 0 ma, 0 to ma Load resistance : Voltage ; 00 kω or more Current ; 00 Ω or less : The acceleration data is obtained at every second by the calculation of rotation speed, circumferential speed, moving speed. *VDEF; Speed difference for second : Measuring the time duration until the stop command value is reached from the start command value in rotation speed, circumferential speed, and moving speed. Start command value, stop command value; 0 to numeric input : MC./0-ST. Made by Phoenix GmbH & Co. KG (Germany) System configurations Detector Cable Display/calculation External devices MP-98 Main rotation detectors Type Electromagnetic Magnetoelectric Photoelectric MP-900 etc. MP-98 etc. TM-00 series Model name Features and measurement range Type No power requirement, excels in durability Oil-proof, heat-resistant, and compact, various s to fulfill the requirements (at 0P/R) MP-900: 00 to,000 r/min Detection from nearly 0 r/min Outputs stable square signal from ultra-low to high speeds Acid-resistant, water-proof (AP-98) to 0,000 r/min at 0 P/R Applicable detector and signal cable R0-PBF Rotary encoder Analog BCD Comparator RS-C Model name MP-80, 80, 80 RP-Z etc. Analog meter Recorder Various s of controllers Printer Computer PLC* etc. Personal computer * Programmable Logic Controller *Please refer to the exclusive brochure of each model in details. TM.-.S Features and measurement range Detection form nearly 0 r/min Models with various pulse s are available. -phase difference (90 degree) wave (at 00P/R or less) 0 to,000 r/min Applicable model Cable Specification Cable model MP-900, 90, 900, P- HSPA- TM.-.S MX- 0 m 90A, 9 (-core outer shielded cable) 0 0 m MP-80, 80, m (MP-08 + MX-00 series) MP-90/9/9/90/9/ 9 FG-00 MP-98/980 LG-900 LG-900, 90 FS-00+FG-00 Small photoelectric detector, a unified structure of light source and receiver Using a pulse modulation method prevents from being affected by ambient light (Using the exclusive reflective mark HT-0) LG-900 LG-90 Maximum response speed 0 m/s m/s Detection distance 0 mm max. 70 to 00 mm Fiber sensor allows using at narrow area. (Using the exclusive reflective mark HT-0) Maximum response frequency : 0 khz or less Detection distance : 9 mm max. C-V (High frequency coaxial cable) P- (-core outer shielded cable) D-UL (Composite -core vinyl sheath cable) B plug B jack Electromagnetic Line speed meter RP-700 series B plug TM.-.S Rotation shfat directly attached MP-80: Base mount MP-80: Dual shaft MP-80: Frange to,000 r/min Line speed can be easily measured just applying the roller to the measurement target. 0 to 00 m/min MX- 0. m 0 m 0 0 m* m* 0 0 m* MX m (conjunction cable) MX- 70 m 70 0 m 7 m 70 0 m Table of optional card combination Name of optional card TM-0 TM-0 TM-00 TM-00 TM-00 TM-00 BCD BCD Analog Comparator RS-C DC power (voltage) (open collector) operated TM-0 TM-0 X TM-0 TM-0 : Provided as standard. : Provided as an option. X : Can not be built-in. Notes) TM-0 or TM-0 and TM-00 cannot be assembled in the same system configuration. TM-0 and TM-0 cannot be assembled in the same system configuration. External control signal input (start, stop and reset) Function : Start, stop and reset Input voltage : Hi level; +. to +. V Lo level; 0 to +0.9 V Non-voltage input : Open voltage; ±0. VDC max. Short-circuit current; ma max. resistance; 0 Ω or less Timing of signal OFF 0. s or more 0. s or more Hi Lo RP-700 series TM-00 series MP-9/99 AP-98 SP-0ZA D-UL (Composite -core vinyl sheath cable) General power cable RMBPE-S Crimping terminal M TM.-.S AC plug P No need ( is directly attached to the detector itself. Another end is processed as open status. ) RP-08 m 0 m* AX-00N m (conformed to Electrical Appliances and Materials Safety Act) *made to order 7

5 Greatly improved functions in all models of TM-00 series (provided as standard in all models) TM-00: Supporting the higher performance of the measurement (option) * The following functions are available by mounting TM-00 (RS-C/gate card). Display function SS function* Measurement of the rotation change rate Measurement of the section data Displayed refresh time can be changed by customer. * Select one of the followings as refresh time: 0. s, 0. s, 0. s, 0. s, 0.8 s, or.0 to 0 s (.0 s step). The displayed value shows the average in the setting of refresh time. Moving average function The moving average of measurement value can be displayed and with this function. It reduces variation in display values and enables changes in rotation speed to be displayed smoothly thus making it easy to check rotation phenomena. The number of moving average times : OFF,,, 8,,,, 8 Relation to analog : Analog is obtained by processing moving average the values calculated at every 0 ms. Auto zero function This function makes the displayed value at zero when there is no signal input to tachometer for a fixed period of time. It can be also used when you do not want to display a rotation value which falls under the setup level in advance. * Select one of the following ranges: OFF, 0.,,,,,,, 7, 8, 9, or 0 seconds OFF: The display will show zero if there is no signal input for seconds or more. Example: If the time for auto zero function is set at second (factory setting at the shipment), it becomes as followings. This function starts measurement after rotation speed reaches a setup value and continues measurement for a setup period of time. This function can measure the average, maximum, and minimum values between start and stop. This is ideal for checking the stability of rotation speed. Measurement time Start value (Numeric input) Maximum value Average value using the SS function SHORT: second MANUAL mode Select an average time SS function LG: 0 seconds AUTO mode If the measurement time is hour or less, the average time is SHORT. set automatically If the measurement time is hours or more, the average time is LG. The function calculates the section average value over the measurement time using the average values for the SHORT or LG. *SS function : Function for the measurement during the specified time by setting time from START to STOP Panel condition memory T Minimum value T Select one of the followings as measurement time: s, s, 0 s, 0 s, min, min, 0 min, 0 min, h, h, h, 8 h, h, h, or 0 h Measuring the fluctuation in rotation (rotation change rate). Rotation change has an adverse affect on quality, and could damage the rotating body itself. Calculation method Change rate (%) = Latest measurement value reference value reference value x 00 Reference value: () User setting value () Average at s interval (summation avarage value at every 0 ms) Example : Detecting fluctuation in the rotation of the roll for pulp, magnetic tape, or industrial-film winder RP-700 series Roller encoder Line speed measurement TM-00 series This function is used to calculate and store the average, maximum, minimum values and section change rate in setup time at every section. Select one of the following time sections as section time: s, s, 0 s, 0 s, min, min, 0 min, 0 min, and 0 min Maximum number of sections: 8 Memory modes Ring-buffer mode : This function is to delete section memory in order of the oldest one and continue to store the latest section data when number of section data exceeds 8. Memory-full mode : The storing of the data will be completed after the data for 8 sections are stored. Section change rate (%) = (Maximum value for each section average value) average value x 00 Example: Data just before abnormal rotation is occurred can be detected. <Using ring-buffer mode> Normal Abnormal rattle Pulse input is P/R Pulse is input continuously. Pulse is input intermittently. 0. seconds 0. seconds 0. seconds 0. seconds second (setting value) = Hz T Hz x 0 seconds = 0 r/min Display 0r/min Display is 0 r/min Output is 0 V = Hz T The value under Hz is not displayed by the above setting. This function is used to store and recall the measurement condition (parameter). Up to four sets of conditions can be stored. When the object being measured or the measurement conditions are changed, one of the stored sets of conditions can be recalled, enabling measurement to start immediately. Quickly start measurement r/min Measurement conditions change Change Object being measured changes r/s Recall conditions Example : Diagnosis of the motor Rotation is stable. Belt drive Motor Gear Rotation is not stable. rattle Memory Save data for each section 8 When data has been saved for 8 sections, the oldest section is deleted and the latest data is always saved there. Memory T-n T- T0 T Abnormal at rotation speed Data before the abnormality is occurred is also saved This makes it possible to learn the status just before the abnormality is occurred. Rapid deceleration follow-up function If the input signal rapidly decreases and there is no signal input for approx. second or more, the rotation speed (both displaying and values) decreases automatically and zero is displayed after approx. seconds. Rotating Continuous pulse Stopped Mount low-pass filter (LPF) on input The LPF cancels chattering and noise in the input signal. This enables the speed of rotation to be measured more accurately. Chattering Pulse function When the LPF is selected (select one of the followings: OFF, 0 khz) All models are equipped with the pulse function. This is useful function when the measurement requires the rotational pulse signal such as tracking analysis and so on. D slot P-OUT COM Normal motor Abnormal Measurement of the acceleration by calculation The acceleration can be measured by the calculation of rotation speed, moving speed and circumferential speed. Example: Measuring acceleration for car acceleration testing or engine idling Measurement of the reached speed time Measuring the time duration that the stop command value is reached from the start command value in rotation speed, circumferential speed, and moving speed. Example: Car acceleration testing Intermittent pulse When there is no pulse input for second Previous models (TM-00 series): Pulse converter is required. Displays 0 r/min after approx. seconds Pulse conversion display To analyzer 0 km/h 00 km/h +V 0 Output is 0 V TM-00 series New models (TM-00 series): It s pulses directly from TM-00 series. display To analyzer Pulse conversion TM-00 series Reached speed time Display the acceleration, which is calculated at every second interval. Acceleration (rad/s ) = [rotation speed (latest) rotation speed (from second earlier)] x RAD ( second) Acceleration (r/s ) = [circumferential speed (latest) circumferential speed (from second earlier)] ( second) Acceleration (m/s ) = [moving speed (latest) moving speed (from second earlier)] ( second) * RAD =.8 radians/second 8 9

6 Rear panel Terminal block screw: M <Example> Slot name POWER A B C D Optional unit EXTERNAL (RS-C+GATE) DC POWER ( to VDC) POWER A B C D AC COMP BCD EXTERNAL ANALOG INPUT RXD 00-0 V V/I + V TXD CTS COM COM 0/0 Hz RTS COM SIG MAX 0 VA COM 7 START 8 STOP P -OUT 9 RESET 0 COM COM Noise measures installation diagram Parts list (Recommended by O SOKKI) Parts name Manufacturer Model name Line filter TDK Corporation ZHC0-* Base for surge killer O SOKKI CO., LTD. MADE IN JAPAN Phoenix GmbH & Co. KG (Germany) RS-C GATE F-MS ST* VAL-MS 0ST* VAL-MS 0ST* VAL-MS-BE* *Or equivalent model AC IN POWER DC + - V - MAX VA Line filter TM-00 series Function ground Control panel * Make the signal cable as short as possible. To shield all input and signal cables, connect both ends to the ground terminal of the panel for grounding. Cautions on installation for CE marking and EMC Use the TM-00 series tachometer to be mounted in a rack or the like. Use a shielded cable as the signal cable. Separate the instrument as much as possible from an apparatus which generates strong high frequency signal or surge in order to use a surge killer and a line filter. After grounding the FG terminal ( ) of the digital tachometer to the panel, connect the panel to ground. Analog (TM-0, TM-00) Connection of the cable V/I COM Voltage or current is selectable. Response Feature Comparator (TM-0, TM-00) UPPER value=00 r/min Hysteresis function It s the analog signal with high-speed response at any measurement even though there is rapid fluctuation. Each and every instantaneous rotation speed can be measured accurately. TM-0 (previous model) F/V conversion 0 ms±0 ms or 700 ms±00 ms It s signals smoothly even though the rotation of measurement object is not stable. TM-0 (new model) D/A conversion Selectable from followings: 0 ms, 0 ms, 0 ms, 00 ms, 00 ms, 00 ms, s It s signals with high-speed response to rotational fluctuation.* * Moving average function reflects the result of analog when the moving average function is used. Rapid fluctuation High speed Low speed fluctuation of rotation speed D/A conversion F/V conversion Output refresh time : 0 ms The contact becomes when it is UPPER < = rotation speed. The contact becomes when it is LOWER > rotation speed. Example: Set the upper limit value at 00 r/min in order to signal when the measured value exceeds 00 r/min. (UPPER setup) Slot name Standard Option POWER AC power input unit Slot A Comparator unit Slot B External unit Slot C Analog unit Slot D Signal input unit BCD terminal (TM-0, TM-0) Pin number and signal 8 8 HDRA-EMA+ (connector) HDRA-ELPTH (case) -pin half pitch BCD pin assignment Pin Common to all models TM-0 (Comparator ) TM-0 (BCD, open collector ) TM-0 (Analog ) Common to all models Signal Pin Signal Pin BCD X 0 0 X 0 0 X X 0 0 BCD X 0 BCD X 0 X 0 X 0 8 X 0 BCD X 0 X 0 X 0 8 X 0 BCD X 0 X 0 X 0 8 X to 0 VAC (0/0 Hz) TM-00 to VDC ± % DC power operated card s of -digit upper-/lower limit settings TM-00 s of -digit upper-/lower limit settings Comparator card BCD open-collector -digit parallel Applicable connector: HDRA-EMA+ (connector) HDRA-ELPTH (case) -pin half pitch Honda Tsushin Kogyo Co., Ltd. (Japan) Selectable from voltage or current Output voltage range: 0 to 0 V, 0 to V, to V Output current range: to 0 ma, 0 to ma Selectable from AC or DC amplification Voltage/non-voltage Applicable detector : MP, LG, RP series X 0 X 0 8 X 0 BCD X 0 X 0 X 0 8 X Signal Start input Stop input Reset input Data request Print command GND TM-0 BCD card (voltage ) TM-00 RS-C card TM-00 Analog card BCD voltage -digit parallel Applicable connector: HDRA-EMA+ (connector) HDRA-ELPTH (case) -pin half pitch Honda Tsushin Kogyo Co., Ltd. (Japan) Applicable connector : MC, /0-ST, Phoenix GmbH & Co. KG (Germany) Normal mode Output the print command at every approx. s. BCD data Print command Selectable from voltage or current Output voltage range: 0 to 0 V, 0 to V, to V Output current range: to 0 ma, 0 to ma Approx. 00 ms Approx. 0 ms Request mode Output the data by the each external request signal. The minimum interval is 0 ms. Request signal BCD data Print command Approx. 0 ms 0 ms or less 0 ms or more Approx. 0 ms Delay time Shot time The hysteresis function does not reset immediately even though the rotation speed falls below the UPPER value. Prevent an error determination due to the affect of noise Use the hysteresis function of automatic recover function UPPER The signal is fluctuated due to electrical noise. Hysteresis Automatic recover function The comparator automatically recovers when the rotation speed falls below the setup upper level (00 r/min in this example). The rotation speed of comparator recovery can be changed by using hysteresis function. When the hysteresis is setup at 0%, rotation speed recovers when it is 90 r/min. 00 r/min 00 r/min x 0.=90 r/min * Setup range: 0 to ±0 % in % step When the hysteresis is setup at 0 %: to be contact = of recovery When the hysteresis is setup at other than 0 %: to be contact of recovery Output hold function The state of contact is held unless the reset signal is input. When the rotation speed exceeds 00 r/min, the comparator signal is and held its state. Delay function The state will be contact when the rotation speed continuously exceeds the setup value for a certain period of time (delay time). * Setup range: 0 to 000 ms in 0 ms steps Shot function The time of holding contact (shot time) can be setup. The state will be automatically contact OFF after the holding time. * Setup range: OFF, 0 to 000 ms, in 0 ms steps Using hysteresis function prevents an error determination that the rotation speed falls below the UPPER level. (Not to be contact OFF) Prevent the device from being destroyed Use the delay function UPPER Setup delay time When the rotation speed keeps continuously above the UPPER level, it determines the risk of destruction. (To be contact ) 0

7 Outer Dimensions (unit: mm) 9 99 or more 8 or more Panel cutout dimensions 9. PANEL THICK MAX 8 POWER A B C D AC COMP BCD EXTERNAL ANALOG INPUT RXD 00-0 V V/I + V TXD CTS COM COM 0/0 Hz RTS COM SIG MAX 0 VA COM 7 START 8 STOP P -OUT 9 RESET 0 COM COM RS-C GATE O SOKKI CO., LTD. MADE IN JAPAN TM-00 () (0) Model name Product name Remarks TM-0 Digital Tachometer Display only TM-0 Digital Tachometer BCD (open collector) TM-0 Digital Tachometer Analog TM-0 Digital Tachometer Comparator TM-0 BCD voltage card TM-0 BCD open collector card Open collector TM-00 Analog card TM-00 Comparator card TM-00 RS-C card RS-C, GATE TM-00 DC power operated card AA-807 BCD cable m, another end is processed as open status. AX-00N General power cable m Crimping terminal-p * Microsoft Windows are registered trademarks of Microsoft Corporation in the United States and other countries. Other product names are trademarks or registered trademarks of each individual company. The copyrights are reserved by each individual company. WORLDWIDE O SOKKI CO., LTD. -- Hakusan, Midori-ku, Yokohama, -807, Japan Phone : Fax : overseas@onosokki.co.jp Outer appearance and specifications are subject to change without prior notice. * URL: U.S.A. Ono Sokki Technology Inc. 7 Executive Drive, Suite 00, Addison, IL. 00, U.S.A. Phone : Fax : info@onosokki.net THAILAND Ono Sokki (Thailand) Co., Ltd. /9- Moo.9 T.Bangphud A.Pakkred, Nonthaburi 0, Thailand Phone : Fax : sales@onosokki.co.th INDIA Ono Sokki India Private Ltd. Plot No.0, Ground Floor, Sector-, IMT Manesar Gurgaon-00, Haryana, INDIA Phone : Fax : osid@onosokki.co.in P.R.CHINA Ono Sokki Shanghai Technology Co., Ltd. Room 0, No.7 Zhengyi Road, Yangpu District, Shanghai, 00, P.R.C. Phone : Fax : admin@shonosokki.com CAT. NO. 9-0E Printed in Japan 80 (SUN) 0.K

Simplified Operations for TM-3100 Series Digital Tachometer

Simplified Operations for TM-3100 Series Digital Tachometer Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,

More information

Digital Tachometers/Sensors and Peripherals. LG/SP/MP/RP series FV/FT/PA/TM series

Digital Tachometers/Sensors and Peripherals. LG/SP/MP/RP series FV/FT/PA/TM series Digital Tachometers/Sensors and Peripherals LG/SP/MP/RP series FV/FT/PA/TM series Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that

More information

Advanced Tachometer FT-2500

Advanced Tachometer FT-2500 // No rotational pulse signal is required for a measurement. The rotational speed is calculated from the frequency signal of light, magnetism, vibration, and sound. The is an advanced tachometer which

More information

TM-2100 Series. Digital Tachometer INSTRUCTION MANUAL ONO SOKKI CO., LTD. SIG SIG SIG SIG DIGITAL TACHOMETER TM-2130 DIGITAL TACHOMETER TM-2110

TM-2100 Series. Digital Tachometer INSTRUCTION MANUAL ONO SOKKI CO., LTD. SIG SIG SIG SIG DIGITAL TACHOMETER TM-2130 DIGITAL TACHOMETER TM-2110 TM-2100 Series Digital Tachometer INSTRUCTION MANUAL DIGITAL TACHOMETER TM-2110 DIGITAL TACHOMETER TM-2130 SIG SIG TM-2110 TM-2130 DIGITAL TACHOMETER TM-2120 DIGITAL TACHOMETER TM-2140 SIG SIG LOWER 1

More information

Torque Station Pro TS-7700 System

Torque Station Pro TS-7700 System For Motor Torque Measurement Torque Station Pro TS-7700 System The Torque Station Pro is designed to automatically measure motor torque characteristics. The compact configuration includes a built-in brake

More information

Advanced Tachometer FT A digital tachometer that doesn't require. rotational pulse signals. FFT calculations performed by the device enable

Advanced Tachometer FT A digital tachometer that doesn't require. rotational pulse signals. FFT calculations performed by the device enable Advanced Tachometer A digital tachometer that doesn't require rotational pulse signals FFT calculations performed by the device enable measurement of rotational speed by sensing fluctuations in rotation-synchronized

More information

Advanced Tachometer FT-2500

Advanced Tachometer FT-2500 // No rotational pulse signal is required for a measurement. The rotational speed is calculated from the frequency signal of light, magnetism, vibration, and sound. The is an advanced tachometer which

More information

Measurement Microphone MI Series

Measurement Microphone MI Series Measurement Microphone MI Series Types to suit your needs include high sensitivity and wide frequency models. High degree of environmental stability against temperature and humidity. Condenser-type microphone

More information

LCSeries. Non-contact Speedometers SPEEDOMETER

LCSeries. Non-contact Speedometers SPEEDOMETER SPEEDOMETER Non-contact Speedometers LCSeries The LC-series is on-vehicle type of non-contact, non-marking speed measurement system with high accuracy. High-speed tests up to a maximum 320 km/h can be

More information

Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer.

Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer. Digital Tachometers / Sensors and Peripherals Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer. Rotation

More information

Stepping Motor Station

Stepping Motor Station Stepping Motor Station PV-7300 System A single system can measure all seven of the characteristics important in a stepping motor, namely the -T characteristic, holding torque, detent torque, pull-in torque,

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

Non-contact Thickness Meters/Displacement Meters

Non-contact Thickness Meters/Displacement Meters Non-contact Thickness Meters/Displacement Meters (Electrostatic capacitance type) Non-contact displacement meters VT-5200/5700 Series Gap detectors VE Series New advances have been made in displacement

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

CF Comparator CF-4500

CF Comparator CF-4500 Comparator The FFT comparator can be used as an OK/NG judgment machine on production lines for accurate quality inspection by sound or vibration from products. As featuring our accumulated FFT technology

More information

SPECIFICATIONS Digital Indicator 1. General

SPECIFICATIONS Digital Indicator 1. General SPECIFICATIS Digital Indicator 1. General The instrument is a digital indicator for the purpose of instrumentation, and suitable for the application in hopper, tank scale, and so on. 2. Specifications

More information

NPN PNP NPN PNP NPN PNP

NPN PNP NPN PNP NPN PNP Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles

More information

FT-2500 Advanced Tachometer Operation manual

FT-2500 Advanced Tachometer Operation manual FT-2500 Advanced Tachometer Operation manual ONO SOKKI CO., LTD. Simplified Operation Manual for FT-2500 Advanced Tachometer FT-2500 Advanced Tachometer is a new rotational speed indicator that analyses

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from to 1 MHz CLAMP ON PROBE 3276 1 CLAMP ON PROBE 3273-5 to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due

More information

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-speed, High-Accuracy Digital Displacement Inductive Sensor EX-V Series High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-Performance

More information

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments. 2004 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3

More information

Absolute Rotary Encoder

Absolute Rotary Encoder Absolute Rotary Encoder Use the Tough (Rated IP64 for Degree of Protection) Combined with a PLC or Cam Positioner for Optimum Control and Ease-of-Use Incorporates a sealed bearing, meeting IP64 for durability

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec, code is not specified. ) VM-703 /NB1 /CSU /TRP /TB Non-incendive * 1 Custom set up Tropical spec. I/O terminal block for: 1

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

Vibration Comparator

Vibration Comparator Vibration Comparator The VC-2100 can serve as your vibration "watchdog" in a wide of situations in which vibration-based judgments must be made, such as in go/nogo vibration testing of products, facilities

More information

DIGITAL HiTESTER 3237, 3238, 3239

DIGITAL HiTESTER 3237, 3238, 3239 DIGITAL HiTESTER,, 3239 4-terminal Ω function Advanced model Economically priced 3239 Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed 5 1 /2 digit DMM The DIGITAL

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

HITEK POWER OLS10K SERIES

HITEK POWER OLS10K SERIES 10 KW HIGH VOLTAGE POWER SUPPLIES The HiTek Power OLS10K series range of single-output high voltage power supplies meets the exacting requirements found in electron-beam, ion-beam, and x-ray systems, as

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

BS-3520 Digital Indicator

BS-3520 Digital Indicator BS-3520 Digital Indicator The Better Way for Weighing & easurements Table of Contents. Introduction...3 - Trait... 3-2 Warning... 4 2. Specification...5 3. External Size...6 4. Description on Front Panel...7

More information

Analog Timer TTL Series

Analog Timer TTL Series Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification

More information

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

96M0374. Instruction Manual. Analog Sensor Controller. RD Series Instruction Manual Analog Sensor Controller RD Series 96M0374 Safety precautions This manual describes how to install the RD Series as well as its operating procedures and precautions. Please read this

More information

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool An Energy Saving Support Tool POWER HiTESTER Power Measuring Instruments 3332 STANDBY MODE OFF MODE Single-phase, 2-wire type that can accurately measure even standby power Accurate evaluation of consumption

More information

CQM1H-MAB42 Analog I/O Board Connector CN1: Analog inputs 1 to 4. Name Specifications Model number Slot 1 (left slot) High-speed Counter Board

CQM1H-MAB42 Analog I/O Board Connector CN1: Analog inputs 1 to 4. Name Specifications Model number Slot 1 (left slot) High-speed Counter Board Inner Boards The six available Inner Boards are shown below. Inner Boards can be mounted in slot 1 or slot 2 of a CQM1H-CPU51 or CQM1H- CPU61 CPU Unit. (Some Inner Boards must be mounted in either slot

More information

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES Series OLH10KD FEATURES 10kW of output power Wide dynamic range with dual supply configuration Output voltages from 60kV to 500kV for high range Output voltages from 6kV to 10kV for low range Robust IGBT

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for sensors with incremental output Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7 Page 1 of 7 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-701B /PM /AL Phase Marker Function Analysis Function 0 Without 0 Without With Y With 1 (When /ALY

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet True RMS Bench Multimeter 5492B True RMS Bench Multimeter The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222 EECTRIC (with pre-scaling function) C-S Counters C-S -digit type -digit type pin type type U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Proposing control by a hydraulic servo and V/F inverters

Proposing control by a hydraulic servo and V/F inverters Drive Goods SSCNET III/H Analog Speed Command Unit (Number of Control Axes: Axes) [DGAF/DGAF-P0] New Product Release No. Proposing control by a hydraulic servo and V/F inverters using a SSCNET III/H compatible

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

Bipolar Output Working Standard

Bipolar Output Working Standard 6166 DC Voltage/Current Source 6½-digit working standard suitable for calibration High-accuracy and highly stable with bipolar output l Wide dynamic range and high resolution Voltage source: ±10nV to ±1200V

More information

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC Simple, scalable and economical Service Bosch Rexroth

More information

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e Sendix H00 (shaft) The Sendix encoder H00 is an extremely rugged available in 3 versions: encoder with or without speed switch and double encoder. Thanks to the special HD-Safety-Lock construction it is

More information

High-speed DMM. DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced)

High-speed DMM. DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

Select datum Page backward in. parameter list

Select datum Page backward in. parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

Electrical Measuring Instruments. Vol.3.

Electrical Measuring Instruments. Vol.3. Electrical Measuring Instruments GENERAL CATALOG ol.3 www.kaise.com Contents Clamp Meters Insulation Testers Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories Digital Clamp

More information

Multi Function Timer with Free power, Compact size W38 H42mm

Multi Function Timer with Free power, Compact size W38 H42mm Multi Function with Free power, ompact size W8 H4mm Features Wide power supply range : 100-40VA 50/0Hz, 4-40VD (universal), 4VA 50/0Hz / 4VD (universal), 1VD Various output operations( operation modes)

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

SHIMADEN PROGRAM CONTROLLER

SHIMADEN PROGRAM CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 02B ABSOLUTE VIBRATION Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec, code is not specified. ) 02B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

Connection and Operation

Connection and Operation Connection and Operation LED Display Control Module Motor Regeneration Unit Terminals Power Connection Terminals Protective Earth Terminal Internal Potentiometer Acceleration Time Potentiometer Deceleration

More information

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE HITEK POWER XR1000 1 KW X-RAY POWER SUPPLY MODULE Component power supply for industrial x-ray systems, elemental analysis equipment, x-ray diffraction spectrometers, and materials process monitoring applications

More information

Connection and Operation

Connection and Operation Connection and Operation Names and Functions of Parts 4 1 Monitor Display LED Indicators DG60 1 5 Motor Connector Power Connector Indication Color Function When Activated OPERATI Green Power Supply Indication

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,

More information

RoHS Directive-Compliant Compact Linear Actuators DRL Series. Features

RoHS Directive-Compliant Compact Linear Actuators DRL Series. Features Motorized ctuators RoHS Directive-Compliant Compact Linear ctuators DRL Series In the compact linear actuator DRL Series, the drive mechanism adopts a -phase stepping motor with ball screw. This series

More information

Absolute Encoders - Singleturn

Absolute Encoders - Singleturn The Sendix 5853 and Sendix 5873 singleturn encoders with SSI or BiSS interface and optical sensor technology can achieve a resolution of max. 7 bits. These encoders are also available with an optional

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale. Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric

More information

Integrated Easy Servo

Integrated Easy Servo ies 1706 Integrated Easy Servo Motor + Drive + Encoder, 18 32VDC, NEMA17, 0.6Nm Features Easy servo control technology to combine advantages of open loop stepper systems and brushless servo systems Closed

More information

Absolute encoders - SSI

Absolute encoders - SSI with through hollow shaft Features Encoder multiturn / SSI Optical sensing method Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit. Rotary s Model Designations - mini Series st+nd digits 3rd digit th digit th digit 6th digit 7th digit st+nd digits Rated Output th digit Design Revision Order 7th digit Options Code Code Code B3 3.3 W

More information

3DM phase Digital Stepper Drive

3DM phase Digital Stepper Drive 3DM2283 3-phase Digital Stepper Drive 150-220VAC, 0.5-8.2A peak, Auto-configuration, Low Noise Anti-Resonance provides optimal torque and nulls mid-range instability Motor auto-identification and parameter

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

60 mm sq. (2.36 inch sq.)

60 mm sq. (2.36 inch sq.) 6 mm sq. (.36 inch sq.) 1.8 /step RoHS Unipolar winding, Connector type Unipolar winding, Dimensions for attaching NEMA3 are interchangeable (47.14 mm-pitch) Bipolar winding, Connector type p. 76 Bipolar

More information

ies-2309 Integrated Easy Servo

ies-2309 Integrated Easy Servo Datasheet of the integrated easy servo motor ies-09 ies-09 Integrated Easy Servo Motor + Drive + Encoder, 0-0VDC, NEMA, 0.9Nm Features Easy servo control technology to combine advantages of open-loop stepper

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

High-precision portable RESISTANCE METER

High-precision portable RESISTANCE METER 8 High-precision portable RESISTANCE METER measures from µω to MΩ Features High-precision specs in a portable package(high accuracy of 0.02% rdg.) Design is ideal for maintenance and testing/measurement

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger MEMORY HiLOGGER 8423 Data Logger Fast 10-ms Sampling Up to 600 Channels Data Logging MEMORY HiLOGGER Model 8423 is a data acquisition system capable of measuring and recording multiple channels at high

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY DESCRIPTION The Series OLS10KD range of high voltage power supplies recognises the requirement for high stability and very low ripple over a wide range of output voltages. This is achieved by combining

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES 2001 INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES Safety Standards Measuring Instruments 3153 3159 3158 3154 ISO14001 JQA-E-90091 http://www.hioki.co.jp/ HIOKI company overview, new products,

More information