Hellenic Accreditation System. Annex F2/15 to the Certificate No SCOPE of ACCREDITATION

Size: px
Start display at page:

Download "Hellenic Accreditation System. Annex F2/15 to the Certificate No SCOPE of ACCREDITATION"

Transcription

1

2 Hellenic Accreditation System Annex F2/15 to the Certificate No SCOPE of ACCREDITATION of the Calibration laboratory of ALGOSYSTEMS S.A. Temperature/ Temperature block calibrators Temperature measurements -80 o C... 0 o C 0,08 o C Using platinum resistance 0 o C o C 0,10 o C thermometers, according to guide: EURAMET/cg-13/v.4: o C o C 0,20 o C 400 o C 1000 o C 1,30 o C Using thermocouple type S, according to guide: EURAMET/cg-13/v.4 :2017 Thermocouples -25 o C o C 0,25 o C Using temperature block calibrator 125 o C o C 0,60 o C and platinum resistance thermometer, according to guide: EURAMET/cg- 08/ v.2.1 :2011 Liquid-in-glass thermometers of total immersion Climatic Chambers, furnaces, ovens, incubators, autoclaves, refrigerators, freezers of volume up to 2000 l 400 o C 1000 o C 1,40 o C Using temperature block calibrator and thermocouple type S, according to guide: EURAMET/cg-08/ v.2.1 : o C o C 0,16 o C Comparative calibration in water bath using platinum resistance thermometer -80 o C o C 0,40 o C Using platinum resistance thermometer positioned at one point within the chamber. -25 o C o C 1 o C Using type K thermocouples covering the volume of the chamber. -25 o C o C 0,30 o C Using temperature data loggers covering the volume of the chamber. All calibrations are based on guide: DKD-R 5-7 : 2004 and standard: ELOT ΕΝ :2002, and can also be performed on-site Page 1 of 12 Annex F2/15 to the Certificate ESYD No

3 Chambers, Furnaces, Ovens 400 o C 1000 o C 1,60 o C Using thermocouple type K, located at a point in the center of the cabin. Chambers / Storage rooms of volume > 2000 l 10 o C o C 0,4 o C Using platinum resistance thermometer at one point within the chamber 1 o C Using type K thermocouples at one point within the chamber Liquid baths -80 o C o C 0,10 o C Using platinum resistance thermometer Dissolution testers, disintegration testers Temperature sensors with analog or digital display unit / Analog temperature recorders / Digital temperature recorders Temperature/ Temperature transmitter (span 100 C) with analog signal output (in ma or Volts), connected to temperature sensor Temperature/ Temperature transmitter (span 100 C) with analog signal output (in ma or Volts), connected to temperature sensor Temperature/ Temperature transmitter (span 100 C) with analog signal output (in ma or Volts), connected to temperature sensor 35 C C 0,10 o C Calibration at one point of sample placement using platinum resistance thermometer -40 o C o C 0,10 o C Using climatic chamber -25 o C o C 0,45 o C Using temperature block calibrator 125 o C o C 0,70 o C and platinum resistance thermometer. Instruments under calibration must have external temperature probes. 50 o C o C 0,25 o C Using liquid bath and platinum resistance thermometer Instruments under calibration must have external temperature probes 400 o C 1000 o C 1,50 o C Using temperature block calibrator and thermocouple type S. Instruments under calibration should have external temperature probes -40 o C to 140 o C 0,10 o C 140 o C to 420 o C 0,44 o C 420 o C to 1000 o C 1,5 o C Humidity measurements Calibration method is based on DKD- R Guideline Page 2 of 12 Annex F2/15 to the Certificate ESYD No

4 Relative humidity/ Analog / Digital humidity meters / Humidity recorders Climatic chambers Velocity / Calibration of fixed speed limit monitoring systems Αραιόμετρα / Υγρόμετρα / Πυκνόμετρα Υγρών Volume / Mechanical Digital Pipettes, Dispensers 15 %RH 95 %RH at 25 o C 15% RH %RH at 25 o C 2,3 %RH... 2,9 %RH Using climatic chamber 2,4 %RH... 3,0 %RH Calibration based on Guide: DKD-R 5-7 : 2004 Physical measurements 30 km/h km/h 2,5 km/h Calibration is performed on-site Density Measurements 850 g/cm g/cm 3 6,0*10-4 g/cm 3 6,5*10-4 g/cm 3 Based on Cuckow methodology Volume Measurements 10 μl 100 μl 0,8 % 0,19 % EURAMET cg-19, Version 2.1 ( μl 1000 μl 0,19 % 0,042 % 2012) 1000 μl 10ml 0,042 % 0,009 % Volume / Titrators 0,05 ml 1 ml 0,9 % 0,094 % 1 ml 10 ml 0,094 % 0,024 % 10 ml 100 ml 0,024 % 0,018 % Volume / Siphons Burettes, type «Ex» and «In» with volume V (ml), internal neck diameter D (mm) Volume / Glass- Plastic and metallic volumetric vessels / flasks / containers, type «Ex» and «In» with Volume V (ml), and internal neck Diameter D (mm) 0,2 ml 1 ml/ D=5mm 1,1%... 0,1 % 0,2 ml 1 ml/ D=10mm 4,5%... 0,5% 1 ml 10 ml/ D=5mm 0,1%... 0,02 % 1 ml 10 ml/ D=10mm 0,5%... 0,05 % 1 ml 10 ml/ D=15mm 1,0%... 0,1 % 10 ml 50 ml/ D=5mm 0,02%... 0,009 % 10 ml 50 ml/ D=10mm 0,05%... 0,01 % 10 ml 50 ml/ D=15mm 0,1%... 0,02 % 10 ml 50 ml/ D=20mm 0,2%... 0,04 % 10 ml 50 ml/ D=30mm 0,4%... 0,08 % 50 ml 100 ml/ D=5mm 0,009%... 0,08 % 50 ml 100 ml/ D=10mm 0,01%... 0,08 % 50 ml 100 ml/ D=15mm 0,02%... 0,08 % 50 ml 100 ml/ D=20mm 0,04%... 0,08 % 50 ml 100 ml/ D=30mm 0,08%... 0,08 % 50 ml 100 ml/ D=40mm 0,15%... 0,09 % 1 ml 10 ml / D=5mm 0,12 % 0,016 % ΑSΤΜ E542:2007, ΟΙΜL R- 1 ml 10 ml / D=10mm 0,47 % 0,05 % 120:1996, OIML R-43:1981, ISO 4787:2010, ISBN ml 10 ml / D=15mm 1,1 % 0,1 % 1:2009 IMEKO (p. 2344) 1 ml 10 ml / D=20mm 1,9 % 0,2 % 10 ml 100 ml/ D=5mm 0,016 % 0,01 % 10 ml 100 ml/ D=10mm 0,05 % 0,01 % 10 ml 100 ml/ D=15mm 0,1 % 0,01 % 10 ml 100 ml/ D=20mm 0,2 % 0,02 % 10 ml 100 ml/ D=30mm 0,4 % 0,04 % 100 ml 1 l / D(5mm-10mm) 0,01 % 0,008 % 100 ml 1 l / D=15mm 0,01 % 0,008 % Page 3 of 12 Annex F2/15 to the Certificate ESYD No

5 100 ml 1 l / D=20mm 0,02 % 0,009 % 100 ml 1 l / D=30mm 0,04% 0,009 % 1 l 5 l / D(5mm-15mm) 0,008 % 0,037 % 1 l 5 l / D(20mm-30mm) 0,009 % 0,037 % 1 l 5 l / D(40mm-60mm) 0,02 % 0,037 % 5 l 20 l / D=60mm 0,037 % 0,032 % 5 l 20 l / D=80mm 0,039 % 0,032 % 5 l 20 l / D=100mm 0,040 % 0,032 % Dimensional Measurements Length/ Analog / Digital calipers Depth calipers Analog / Digital external micrometers Sieves Profile projectors / Micrometers with scale 0 mm mm d = (0,01 0,1) mm 0 mm mm d = (0,01 0,1) mm 0 mm mm d = 0,001 mm d = 0,01mm Nominal opening 20μm 125mm 0,6 d Using gauge blocks and gauge rods 0,6 d (0,6 3,7) μm (6 6,9) μm 3,5 μm (with x50 lens) 6,5 μm (with x30 lens) 0 mm mm 3 μm (x30 < lens < x50) 50 mm mm 5 μm (with lens < x30) ISO :2000, ISO :1999, ASTM E11:2009, ISO 5223:1995, EN 933-3:1997 Using glass mircoscales Dial gauges 0 mm mm Comparative measurement R = 2 μm 3,6 μm In laboratory calibration R = 5 μm R = 10 μm R = 20 μm R = 100 μm 4,0 μm 6,4 μm 12 μm 58 μm R = 5 μm 13 μm On site calibration R = 10 μm R = 20 μm R = 100 μm Dial gauges 0 mm mm 0,5 μm Using gauge blocks Cubic moulds for concrete specimens 150 x150 x150 Internal dimensions 0,02 mm Tolerances according to EN :2000 mm Perpedicularity 4 μm Pass / fail check Cylindrical moulds (Standard proctor moulds) 4 in Cylindrical moulds (Modified proctor moulds) 6 in CBR cylindrical moulds (CBR moulds) 6 in 14 μm 17 μm 59 μm Flatness 3 μm Pass / fail check Internal diameter: 101,6 mm or 152,4 mm Height A: 116,4 mm or 177,8 mm Height B: 50,8 mm 0,02 mm 0,03 mm 0,04 mm Tolerances according to ASTM D698: , Tolerances according to ASTM D698: and Tolerances according to ASTM D1883: Page 4 of 12 Annex F2/15 to the Certificate ESYD No

6 Coordinating Measuring Machines ( CMM) One piece rigid or semi-rigid measures of length 0 mm 1500 mm (measuring length in space) 0 mm 3000 mm 1 mm (d=1mm) 0,6d (mm) (d 2mm) [1,2 + (1* length (m))] μm ISO , 7 OIML R , 7.6 d: readability (in mm) Extensionmeters 0 mm 50 mm 0,6μm + (0,85μm per mm) ISO 9513, ASTM E83 DC Voltage (Generation) / DC Voltage Measuring Equipment DC Voltage (Measurement) / DC Voltage Generators DC Voltage (Measurement)/ DC Voltage Calibrators AC Voltage (Generation) / AC Voltage Measuring Equipment Electrical measurements 10 V V 4, U A standard multifunction calibrator 0,1 mv... 1,9 mv 4, U is used for the calibration. 1 mv mv 4, U 10 mv mv 1, U 0,1 V... 1,9 V 5, U 1 V V 3, U 10 V V 5, U 100 V V 1, U 100 μv mv 1, U A standard high-accuracy multimeter >200 mv 2 V 9, U is used for the calibration. > 2 V 20 V 8, U >20 V 200 V 1, U >200 V 1000 V 1, U 100 mv 8, U A standard transfer standard 1 V 4, U (multimeter) is used for the 10 V 2, U calibration. 100 V 3, U 1000 V 4, U 1 mv... 1,9 mv 30 Hz 300 Hz 4, U 300 Hz 1 khz 4, U 1 khz 10 khz 4, U 10 khz 30 khz 4, U 30 khz 100 khz (4, , ) U 1,9 mv mv 30 Hz Hz (6, , ) U 300 Hz... 1 khz 5, U 1 khz 10 khz 6, U 10 khz 30 khz (5, , ) U 30 khz 100 khz (6, , ) U 19 mv mv 30 Hz 300 Hz (2, , ) U 300 Hz 1 khz 1, U 1 khz 10 khz 1, U 10 khz 30 khz (1, , ) U 30 khz 100 khz (2, , ) U 190 mv... 1,9 V 10 Hz 30 Hz 1, U 30 Hz 300 Hz (1, , ) U 300 Hz 1 khz (6, , ) U 1 khz 10 khz 6, U 10 khz 30 khz 6, U 30 khz 100 khz (6, , ) U 100 khz 300 khz (2, , ) U 300 khz 1 ΜΗz (2, , ) U 1,9 V V 10 Hz 30 Hz 1, U A standard multifunction calibrator is used for the calibration. Page 5 of 12 Annex F2/15 to the Certificate ESYD No

7 AC Voltage (Measurement)/ AC Voltage Generators AC Voltage (Measurement)/ AC Voltage Calibrators 30 Hz 300 Hz (1, , ) U 300 Hz 1 khz (6, , ) U 1 khz 10 khz 6, U 10 khz 30 khz 6, U 30 khz 100 khz (6, , ) U 100 khz 300 khz (2, , ) U 300 khz 1 ΜΗz (2, , ) U 19 V V 10 Hz 30 Hz 1, U 30 Hz 300 Hz (1, , ) U 300 Hz 1 khz (6, , ) U 1 khz 10 khz (5, , ) U 10 khz 30 khz 7, U 30 khz 100 khz (7, , ) U 190 V V 40 Hz 300 Hz 1, U 300 Hz 1 khz (1, , ) U 1 khz 10 khz (9, , ) U 10 khz 30 khz (1, , ) U 700 V 100 khz 8, U 10 mv mv 20 Hz 40 Hz 1, U 40 Hz 1 khz 5, U 1 khz 10 khz 6, U 10 khz 30 khz 3, U 30 khz 100 khz 3, U > 200 mv... 2 V 20 Hz 40 Hz 1, U 40 Hz 1 khz 3, U 1 khz 10 khz 4, U 10 khz 30 khz 2, U 30 khz 100 khz 2, U 100 khz 300 khz 3, U 300 khz 1 ΜΗz 3, U > 2 V V 20 Hz 40 Hz 1, U 40 Hz 1 khz 3, U 1 khz 10 khz 3, U 10 khz 30 khz 2, U 30 khz 100 khz 2, U 100 khz 300 khz 3, U 300 khz 1 ΜΗz 3, U > 20 V V 40 Hz... 1 khz 3, U 1 khz 10 khz 3, U 10 khz 30 khz 2, U 30 khz 100 khz 2, U > 200 V V 20 Hz 40 Hz 1, U 40 Hz 1 khz 5, U 1 mv 10 Hz 1 khz (4, , ) U 1 khz 100 khz (4, , ) U 100 khz 500 khz (5, , ) U 500 khz 1 ΜHz (2, , ) U 10 mv 10 Hz 1 khz (6, , ) U A standard high-accuracy multimeter is used for the calibration. A standard transfer standard (multimeter) is used for the calibration. Page 6 of 12 Annex F2/15 to the Certificate ESYD No

8 DC Current (Generation) / DC Current Measuring Equipment DC Current (Generation) / DC Current Clamp Meters DC Current (Measurement) / DC Current Calibrators up to 10 Α DC Current (Measurement) / DC Current Calibrators - Generators up to 100 Α DC Current (Measurement) / DC Current Generators up to 2 Α AC Current (Generation) / AC Current Measuring Equipment 1 khz 100 khz (4, , ) U 100 khz 500 khz (9, , ) U 500 khz 1 ΜHz (3, , ) U 100 mv 10 Hz 1 khz (3, , ) U 1 khz 100 khz (1, , ) U 100 khz 500 khz (5, , ) U 500 khz 1 ΜHz (1, , ) U 1 V 10 Hz 1 khz (2, , ) U 1 khz 100 khz (4, , ) U 100 khz 500 khz (1, , ) U 500 khz 1 ΜHz (1, , ) U 10 V 10 Hz 1 khz (2, , ) U 1 khz 100 khz (4, , ) U 100 khz 500 khz (1, , ) U 500 khz 1 ΜHz (1, , ) U 19 V 1 khz 4, U 100 V 10 Hz 1 khz (2, , ) U 1 khz 100 khz (5, , ) U 100 khz 200 khz (1, , ) U 700V 50 khz 100 khz (2, , ) U 1000 V 40 Hz 1 khz 7, U 1 khz 30 khz (7, , ) U 10 Α Α 9, Ι A standard multifunction calibrator 100 Α 1,9 ma 4, Ι is used for the calibration. 1,0 ma ma 4, Ι 10 ma ma 4, Ι 100 ma... 1,9 A 9, Ι >1,9 A A 1, Ι 2 Α 5, Ι A standard current calibrator with its 20 Α 5, Ι 10-turn Current Coil is used as 100 Α 7, Ι current source Α 6, Ι 100 μα 9, Ι A standard transfer standard (multimeter) is used for the calibration. 1 ma 3, Ι 10 ma 2, Ι 100 ma 4, Ι 1 A 6, Ι 10 A 3, Ι 2 ma ma 1, Ι Standard current shunts and a standard high-accuracy multimeter are used for the calibration. 20 ma ma 1, Ι 200 ma... 2 A (1, , ) Ι 2 A A 2, Ι 20 A A (2, , ) Ι 100 μα... 2 A 1, Ι A standard high-accuracy multimeter is used for the calibration. 10 Α Α A standard multifunction calibrator 10 Ηz 2, Ι is used for the calibration. 300 Hz 2, Ι 1 khz 3, Ι 5 khz 3, Ι Page 7 of 12 Annex F2/15 to the Certificate ESYD No

9 AC Current (Generation) / AC Current Clamp Meters, 50 Hz AC Current (Measurement) / AC Current Calibrators up to 10 Α AC Current (Measurement) / AC Current Calibrators - Generators up to 100 Α AC Current (Measurement) / AC Current Generators up to 2 Α 4-wire Resistance (Generation) / Resistance Measuring Equipment 100 Α... 1,9 ma 10 Hz 2, Ι 300 Hz 1, Ι 1 khz 2, Ι 5 khz 2, Ι 1,0 ma ma 10 Hz 2, Ι 300 Hz 1, Ι 1 khz 2, Ι 5 khz 2, Ι 10 ma ma 10 Hz 2, Ι 300 Hz 1, Ι 1 khz 2, Ι 5 khz 2, Ι 100 ma... 1,9 A 10 Hz 3, Ι 300 Hz 3, Ι 1 khz 4, Ι 5 khz 5, Ι >1,9 A 10 A 300 Hz 4, Ι 1 khz 7, Ι 5 khz 2, Ι 10 khz 6, Ι 2 Α 2, Ι A standard current calibrator with its 20 Α 2, Ι 10-turn Current Coil is used as 100 Α 4, Ι current source Α 6, Ι 100 μα 10 Hz 5 khz (3, , ) Ι 1 ma 10 Hz 5 khz (2, , ) Ι 10 ma 10 Hz 5 khz (2, , ) Ι 100 ma 10 Hz 5 khz (2, , ) Ι 1 A 20 Hz 5 khz (2, , ) Ι 10 A 40 Hz 10 khz (3, , ) Ι 2 ma ma 50 Hz 1 khz 1, Ι 20 ma ma 50 Hz 1 khz 1, Ι 200 ma 2 A 50 Hz 1 khz 1, Ι 2 A. 20 A 50 Hz 1 khz 1, Ι 20 A. 100 A 50 Hz 1 khz 1, Ι A standard transfer standard (multimeter) is used for the calibration. Standard current shunts and a standard high-accuracy multimeter are used for the calibration. 10 mα... 2 A 30 Hz 300 Hz 1, Ι A standard high-accuracy multimeter is used for the calibration. 300 Hz 1 khz 1, Ι 1 khz 5 khz 3, Ι 10 Ω 2, R A standard multifunction calibrator 100 Ω 1, R is used for the calibration. 1 kω 8, R Page 8 of 12 Annex F2/15 to the Certificate ESYD No

10 2-wire Resistance (Generation) / Resistance Measuring Equipment Resistance / Insulation testers, Megohmmeters Resistance (Measurement) / Resistance Calibrators 4-wire Resistance (Measurement) / Standard Resistors 2-wire Resistance (Measurement) / Standard Resistors Resistance (Measurement) / Current shunts DC Voltage (Generation) / Temperature Indicators without cold junction compensation DC Voltage (Generation) / Temperature Indicators with cold junction compensation 10 kω 8, R 100 kω 1, R 1 ΜΩ 2, R 10 ΜΩ 4, R 100 ΜΩ 2, R 10 Ω 1, R A standard multifunction calibrator 100 Ω 2, R is used for the calibration. 1 kω 1, R 10 kω 2, R 100 kω 1, R 1 ΜΩ 2, R 10 ΜΩ R 100 ΜΩ R 1 ΜΩ 3,7 kω Standard insulation resistors are used 10 ΜΩ 37 kω for the calibration. 100 ΜΩ 370 kω 1 GΩ 3,8 ΜΩ 10 GΩ 38 ΜΩ 100 GΩ 0,95 GΩ 1 ΤΩ 17 GΩ 10 ΤΩ 730 GΩ 100 ΤΩ 1,8 ΤΩ 10 Ω 2, R A standard transfer standard (multimeter) is used for the calibration. 100 Ω 8, R 1 kω 6, R 10 kω 6, R 100 kω 8, R 1 ΜΩ 1, R 10 ΜΩ 2, R 100 ΜΩ 8, R 0,1 Ω 200 Ω 1, R A standard high-accuracy multimeter >200 Ω 2 kω 1, R is used for the calibration. >2 kω 20 kω 1, R >20 kω 200 kω 1, R >200 kω... 2 ΜΩ 2, R >2 ΜΩ 20 ΜΩ 5, R >20 ΜΩ 200 ΜΩ 2, R 0,1 Ω 200 Ω 1, R A standard high-accuracy multimeter >200 Ω... 2 kω 2, R is used for the calibration. >2 kω 20 kω 2, R >20 kω 200 kω 1, R >200 kω 2 ΜΩ 2, R >2 ΜΩ 20 ΜΩ 5, R >20 ΜΩ 200 ΜΩ 2, R 0,001 Ω 5, R A standard current source and a standard high-accuracy multimeter are used for the calibration. 0,01 Ω 2, R 0,1 Ω 1, R 1 Ω 8, R 10 Ω 8, R 100 Ω 8, R ±100 mv (- 270 C 1700 C) ±100 mv (- 270 C 1700 C) 0,07 o C Calibration method is based on EURAMET cg-11 Guideline 0,27 o C Page 9 of 12 Annex F2/15 to the Certificate ESYD No

11 Time / Timers Frequency / Frequency Counters Frequency / Optical Tachometers Revolution frequency / Centrifuges, Centrifuge extractors, Mixers Time / Frequency measurements 0 s s 0,23 s A Rubidium frequency standard and a standard frequency counter are used for the calibration. Calibration in the lab. 1 MHz 14 μhz A Rubidium frequency standard is 10 MHz 230 μhz used for the calibration. Calibration in the lab. 600 rpm (10 Hz) 14, rpm A standard multifunction calibrator and a standard frequency counter are used for the calibration. Calibration in the lab. 900 rpm (15 Hz) 14, rpm rpm (50 Hz) rpm rpm (250 Hz) rpm rpm (500 Hz) rpm rpm (1000 Hz) 0,5 rpm rpm (1500 Hz) 0,8 rpm 0 rpm rpm 9 rpm Using a tachometer. Mass Measurements Mass / Standard weights 1 mg 10 mg 0,01 mg Capability to calibrate standard weights up to (including): OIML Class F2 20 mg 100 mg 0,01 mg,, F1,, 200 mg 0,01 mg,, F1,, 500 mg 0,01 mg,, F1,, 1 g 0,01 mg,, F1,, 2 g 0,02 mg,, F1,, 5 g 0,02 mg,, F1,, 10 g 0,03 mg,, F1,, 20 g 0,03 mg,, F1,, 50 g 0,04 mg,, F1,, 100 g 0,06 mg,, F1,, 200 g 0,12 mg,, F1,, 500 g 0,90 mg,, F2,, 1 kg 1,0 mg,, F1,, 2 kg 1,4 mg,, F1,, 5 kg 3,1 mg,, F1,, 10 kg 8,2 x10 1 mg,, Μ1,, 20 kg 8,2 x10 1 mg,, F2,, 50 kg 1,7x10 2 mg,, F2,, Mass / Non-automatic weighing instruments. 1 mg 0,002 mg According to EURAMET/cg- 2 mg 0,002 mg 18/v.04:11/ mg 0,002 mg 10 mg 0,002 mg Available Standard Weights OIML 20 mg 0,003 mg Class E2 at the range from 1mg to 50 mg 0,003 mg 5kg. Max. grouped load: 11,1 kg 100 mg 0,005 mg 200 mg 0,006 mg Available Standard Weights OIML 500 mg 0,007 mg Class F1 at the range from 1mg to 1 g 0,010 mg 5kg. Max. grouped load: 11,1 kg 2 g 0,010 mg Available Standard Weights OIML 5 g 0,015 mg Class F2 at the range from 1mg to 10 g 0,02 mg 5kg. Max. grouped load: 11,1 kg 20 g 0,03 mg 50 g... 1 kg Page 10 of 12 Annex F2/15 to the Certificate ESYD No

12 Force / Compression testing machines Force / Tensile testing machines 2 kg... 5 kg Available Standard Weights OIML Class F2 at the range from 10kg to 20kg. Max. grouped load: 50 kg 5 kg 10 kg kg 60 kg kg 750 kg kg 3,84 t (5, m + 1,2 N) kg where m : value of mass expressed in kg N : number of substitution loads Force measurements Available Standard Weights OIML Class M1 at the range from 10kg to 700kg. Max. grouped load: 700 kg According to Guide: EURAMET/cg- 18/v.03:03/2011 using substitution loads of known density, that client has, according to lab suggestion. All calibrations are performed on-site Force / Compression testing machines - Force transfer 200 kn 2000 kn 0,01 N/N - Force rate 1 kn/s 100 kn/s 0,8 % - Flatness of machine plates - 2 μm - Self alignment of the upper -1 mv/v 1 mv/v - machine platen. Restrain of movement of the upper platen - Hardness of machine plates 24 HRC 63 HRC 1 HRC - Roughness of machine 0,2 Ra 0,5 Ra (μm) 0,05 μm plates Force / Load Rings, CBR, MARSHAL Loading Machines 0 kn 1 kn 0,03 % Class 0.5 machines 2 kn 20 kn 0,12 %,, 1,, 20 kn 45 kn 0,07 %,, 0.5,, 45 kn 450 kn 0,14 %,, 1,, 600 kn 3000 kn 0,26 %,, 1,, 0 kn 1 kn 0,03 % Class 0.5 machines 2 kn 22 kn 0,11 %,, 0.5,, 20 kn 45 kn 0,10 %,, 0.5,, 45 kn 220 kn 0,13 %,, 0.5,, 220 kn 450 kn 0,13 %,, 0.5,, According to standard ISO : All calibrations can be performed onsite According to ΕΝ Calibrations can be performed on-site 0kN 100 kn 0,07% According to ISO : 2004 & BS Torque Measurements Torque Calibrators 1 Nm 85 Nm 0,25 % Using Standard Weights 85 Nm 700 Nm 0,15 % Torque Meters 1Nm 700 Nm 0,6 % Using Torque Calibrators Pressure/ Gauge relative pressure meters of direct reading/ Analog & digital / Pressure Recorders Pressure measurements 3,5 kpa 100 kpa 3,3*10-5 P + 0,0004 (kpa) where: P : Pressure value in kpa 0,6 ΜPa 10 MPa 1,5*10-5 P + 0,0005 (MPa) where: P : Pressure value in MPa Using Dead Weight Testers Medium: gas According to Guide: EURAMET/cg-17/ v. 03 (04/2017) Page 11 of 12 Annex F2/15 to the Certificate ESYD No

13

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INCO-LABS Plot No. 151, Block No.1 Street No. 101 North Subhan, Safat, Kuwait 13071 Abdulaziz A. Al-Obaidan Phone: 00965-2475 2330 CALIBRATION Valid To: December

More information

CALIBRATION & MEASUREMENT CAPABILITY 1 (CMC) (±) 0.5 C 0.05 C C 0.37 C 0.15 C 0.86 C C %Rh 0.95 %Rh 1.2 %Rh 0.085% IR 0.

CALIBRATION & MEASUREMENT CAPABILITY 1 (CMC) (±) 0.5 C 0.05 C C 0.37 C 0.15 C 0.86 C C %Rh 0.95 %Rh 1.2 %Rh 0.085% IR 0. IAS Accreditation Number CL-159 Accredited Entity Address P.O. Box 31862 Al Khobar 31952 Kingdom of Saudi Arabia Contact Name Arnold Arevalo Quality Manager Telephone +966-13-8571899 Effective Date of

More information

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7.

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7. IAS Accreditation Number CL-132 Accredited Entity Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain Contact Name Mr. Masood Khatib Mr. Raja Kalimuthu Telephone +973 17727450

More information

10.15 Scope of Accreditation

10.15 Scope of Accreditation Accreditation rocedures Calibration Laboratory Accreditation is accredited by the GCC Accreditation Center () in accordance with the recognized International Standard, General requirements for the competence

More information

Mechanical 0.3% 1 to 9999 RPM 1% of reading Tachometer. Up to 24 hours/0.01 Sec 1 Sec Master Stopwatch and Manual Comparison Chemical

Mechanical 0.3% 1 to 9999 RPM 1% of reading Tachometer. Up to 24 hours/0.01 Sec 1 Sec Master Stopwatch and Manual Comparison Chemical IAS Accreditation Number Accredited Entity Address CL-138 & Equipment Service Centre Main Office: Industrial Area, Street No.2, Opp. Bosch Car Service, Po. Box 40570, Doha Qatar Nuclear Gauge Calibration:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JAPAN QUALITY ASSURANCE ORGANIZATION Kyushu testing office 2-33, Miyanojin 3-Chome, Kurume-shi, Fukuoka, 839-0801 Japan Masaya Ishimaru Phone: 81 942 48 7763

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration, Inc. 1 Industrial

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, Unit 8 The Centre Holywell Business Park Northfield Road Southam Warwickshire CV47 0FP Contact: Mr N Morgan Tel: +44 (0)1926 812066 Fax: +44

More information

IAS Accreditation Number RICI Muhammad Abdullah Al-Azzaz Company Limited Address P.O. Box Al-Khobar 31952

IAS Accreditation Number RICI Muhammad Abdullah Al-Azzaz Company Limited Address P.O. Box Al-Khobar 31952 IAS Accreditation Number CL-151 Accredited Entity RICI Muhammad Abdullah Al-Azzaz Company Limited Address P.O. Box 31172 Al-Khobar 31952 Contact Name Muhammad Jawad Ali Technical Manager Telephone +966-13-8346304/

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Avionic and Metrology Centre Unit G1/2 Treforest Industrial Estate Pontypridd CF37 5YL Contact: Mr P Ashurst Tel: +44 (0)1443 849970 Fax:

More information

Dimensional Micrometer 0 to 25 mm / mm mm Grade 1 Gauge Block Caliper- External 0 to 150 mm / 0.01 mm

Dimensional Micrometer 0 to 25 mm / mm mm Grade 1 Gauge Block Caliper- External 0 to 150 mm / 0.01 mm IAS Accreditation Number CL-169 Accredited Entity Address Shop No. 8, Building No. 15, Barwa Village, P.O. Box 15481 Doha, Qatar Contact Name Herbert S. Tarun, Operations Manager Telephone +974 40299729

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration, Inc. 6878 Santa

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ASSOCIATED CALIBRATION, INC. DBA A-CAL 4583 E Eisenhower Circle Anaheim, CA 92807 Marshall Doyle Phone: 714 696 5300 CALIBRATION Valid To: January 31, 2019

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Horizonte #28 entre Astro Rey Sur y Nuevo Amanecer

More information

Up to 1600 kg/1 kg. Precision Balance - Make: Kern, Model: DS 36K0.5 Mechanical Analytical Balances (On site

Up to 1600 kg/1 kg. Precision Balance - Make: Kern, Model: DS 36K0.5 Mechanical Analytical Balances (On site IAS Accreditation Number CL-161 Accredited Entity Address Gate 1006, Villa: 2, Road 3221 Mahooz 332, P.O. Box 728 Kingdom of Bahrain Contact Name K. T. Noushad, General Manager Telephone +973 17720117

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Accredited Calibration Services, Inc. (Marsh

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INNOVATECIS CIA LTD. General Jose Maria Guerrero N69-170 y Alfonso del Hierro Quito, Ecuador 170103 Diego Almeida Phone: 593 260 40607 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 DIGITAL MEASUREMENT METROLOGY INC. (A TRESCAL COMPANY) 26 Automatic Road, Unit 4 Brampton, Ontario, CANADA L6S 5N7 Nana Mantey Phone:

More information

Certificate of Accreditation

Certificate of Accreditation Certificate of Accreditation ISO/IEC 17025:1999 Certificate Number L1048 Digital Measurement Metrology Inc. 26 Automatic Road, Unit 4 Raj Sharma Brampton, Ontario L6S 5N7 Canada Is recognized by the Laboratory

More information

Accreditation No: LAB 131. AL-MEEZAN INDUSTRIAL METROLOGY SERVICES House No. 22, Block C, Sabzazar Scheme Lahore Pakistan

Accreditation No: LAB 131. AL-MEEZAN INDUSTRIAL METROLOGY SERVICES House No. 22, Block C, Sabzazar Scheme Lahore Pakistan Issue : 10/08/15 Accreditation No: Awarded to AL-MEEZAN INDUSTRIAL METROLOGY SERVICES House No. 22, Block C, Sabzazar Scheme Lahore Pakistan The scope of accreditation is in accordance with the standard

More information

AL ANSARI TRADING ENTERPRISE LLC P.O. BOX: 1832 PC: 112 RUWI, MUSCAT OMAN

AL ANSARI TRADING ENTERPRISE LLC P.O. BOX: 1832 PC: 112 RUWI, MUSCAT OMAN This is to signify that AL ANSARI TRADING ENTERPRISE LLC P.O. BOX: 1832 PC: 112 RUWI, MUSCAT OMAN Calibration Laboratory CL-139 has met the requirements of the IAS Accreditation Criteria for Calibration

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FUGRO SUHAIMI LIMITED, YANBU P.O. Box 31720 Yanbu Al-Sinaiyah-41912, Kingdom of Saudi Arabia Mohammed Baquer Hameed Phone: 009663 857

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK code Location code Customers Sites 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Yussof Taha Tel: +673-2-386475

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Southern Calibration oratories Limited Issue No: 038 Issue date: 26 January 2018 Unit 7 Solent Industrial Estate Hedge End Southampton SO30

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Laboratory locations: 19 Iris Road Rogerstone Newport NP10 9LE Contact: Mr R Bale Tel: +44 (0)1633 897225 Fax: +44 (0)1633 897225 E-Mail:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: October

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 8023 Interstate 30 Little Rock, AR 72209 Dustin R. Detten Phone: 214 638 1808 CALIBRATION Valid To: September 30, 2018

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FUGRO SUHAIMI LIMITED Calibration Laboratory Riyadh Building No.124, Najah Street Ishbiliyah, District Riyadh, Kingdom of Saudi Arabia 31451 Mohammed B. Hameed

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METROCAL, INC 3631 44 th Street SE, Suite B Kentwood, MI 49512 Kent Anderson Phone: 616 698 3124 CALIBRATION Valid To: September 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: October

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm IAS Accreditation Number Company Name CL-154 Almeer Technical Services Calibration Laboratory Address Plot No. 100/104, Area 7 P.O. Box 9240 Ahmadi, 61003 Kuwait Contact Name Satyananda Rao, Technical

More information

Scope of Accreditation For Alliance Calibration. Calibration

Scope of Accreditation For Alliance Calibration. Calibration Scope of Accreditation For Alliance 11402 Reading Road Cincinnati, OH 45241 Sidney Taylor 513-769-1200 In recognition of a successful assessment to ISO/IEC 17025:2005 to the following and Measurement Capabilities,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue No: 050 Issue date: 11 September 2017 0310 DPN 175 Lammas Road Corby Northamptonshire NN17 5JF Contact: Mr S MacLeod Tel: +44 (0)1536

More information

Scope of Accreditation For Accurate Instrument Repair, Inc.

Scope of Accreditation For Accurate Instrument Repair, Inc. Scope of Accreditation For Accurate Instrument Repair, Inc. 27122 Burbank Foothill Ranch, CA 92610 Anthony Sargent, Quality Manager 949-454-2874 In recognition of a successful assessment to ISO/IEC 17025:2005

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, Unit 8 The Centre Holywell Business Park Northfield Road Southam Warwickshire CV47 0FP Contact: Mr N Morgan Tel: +44 (0)1926 812066 Fax: +44

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Vietnam LTD.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ENI Labs 3120 Independence Dr. Fort Wayne, IN 46808 Andrew Burd Phone: 260 471 6775 CALIBRATION Valid To: April 30, 2018 Certificate

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that OCS Technologies, Inc. (dba: Ohio Counting

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Alliance Calibration 11402 Reading Road Cincinnati,

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation has assessed the Laboratory of: Rays Precision Calibration, Inc 881-3 Nandino Blvd., Lexington, KY 40511 (Hereinafter called the

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precisión Calibration de Mexico S.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Metrology Division Contact: Mr K Pallett Calibration House Tel: +44 (0)1332 867 700 Castings Road E-Mail: sales@comech.co.uk Derby Website:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 QUALITY SYSTEMS LAB, INC. 7604 North West 6 th Ave Boca Raton, FL 33487 Bryan Wilkerson Phone: 561-999-1896 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone: 972 3 9716596 CALIBRATION Valid To: July 31, 2019 Certificate Number: 4282.01

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NORTHSTAR CALIBRATION, INC th Place NW Owatonna, MN John Moorhouse Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NORTHSTAR CALIBRATION, INC th Place NW Owatonna, MN John Moorhouse Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NORTHSTAR CALIBRATION, INC. 1045 26th Place NW Owatonna, MN 55060 John Moorhouse Phone: 507 444 9111 CALIBRATION Valid To: February 29, 2020 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: December

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAL-TEC, INC. 114 Thruway Park Road Broussard, LA 70518 Chris Grevemberg Phone: 337 839 0450 Email: lab@caltecinc.com CALIBRATION Valid

More information

Accreditation No: LAB 129

Accreditation No: LAB 129 Issue : 10/08/15 Accreditation No: Awarded to RESOURCE INSPECTION CANADA INCORPORATED CO. (Construction Material Testing Laboratory and Calibration Laboratory) Office 44, Building 2126, Road 1529, Block

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Acceso III No. 16 A Nave 10, Parque Industrial Benito

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Bldg#660 King Abdullah Road, Al Waha District, Riyadh,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Korea 775 Gyeongin-ro

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Technical Maintenance, Inc. 4613 Northwest

More information

SERVICE CATALOGUE AND PRICELIST

SERVICE CATALOGUE AND PRICELIST SERVICE CATALOGUE AND PRICELIST Initial version: 9 January 2008 Last updated: 22 January 2018 CONTENTS 1 Service policy... 6 2 Framework and Terms of Service... 7 2.1 Groups of services... 7 2.2 Information

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 AMERICAN GAGE 1131 S. Richfield Rd Placentia, CA 92870 Roger Arnold Phone: 657 216 2600 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INSTRUMENTATION DYNATHERM INC. 4127 Rue Cousens Ville St-Laurent, QC Canada H4S 1V6 Graziano Chila Phone: 514 636 7800 CALIBRATION Valid To: May 31, 2018 Certificate

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 MTS METROLOGY AND CALIBRATION LABORATORY 14000 Technology Drive Eden Prairie, MN 55344 Kevin Rust Phone: 952 937 4790 www.mts.com CALIBRATION

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Rio Bravo, Tamaulipas, México. C.P. 88940 (Hereinafter

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that TECHMASTER ASIA (Thailand) Co., Ltd 5/41

More information

Certificate of Accreditation

Certificate of Accreditation Certificate of Accreditation ISO/IEC 17025:2005 Certificate Number L1050-1 The Tool & Gage House Quality Services Division 538 E. Hebron Street Charlotte NC 28273 has met the requirements set forth in

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Brylen Technologies, Inc. 275 Orange Avenue

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that Productivity Quality, Inc./Advanced Inspection Services, LLC 15150

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Quad State Gauging and Measurement, Inc. (Hereinafter

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 WESTERN STATES CALIBRATION 105 West 2950 South Salt Lake City, UT 84115-3433 Lon Miles Phone: 801 466 1700 CALIBRATION Valid To: February

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS - DRAPER, UTAH 65 E. Wadsworth Park Drive Suite 101 Draper, UT 84020 Curtis Keller Phone:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JOHNSON GAGE AND INSPECTION 5920 W. 21st Street North Wichita, KS 67205 Scott Porter Phone: 316-943-7532 CALIBRATION Valid To: May 31,

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Cornerstone Metrology Service Inc. 7625 Hayvenhurst

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 HN PROFICIENCY TESTING INC. 10219 Coral Reef Way Indianapolis, IN 46256 Henrik Nielsen Phone: 317 713 2988 Web: http://www.hn-proficiency.com/ PROFICIENCY TESTING

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AL HOTY CALIBRATION SERVICES A BRANCH OF AL HOTY CO. LTD. 25 th St. Corner Zulfi St. Thuqbah Al Khobar, Saudi Arabia 31952 Wendell Arevalo Phone: 00966 13 864

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION Valid To: May 31, 2019

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Paseo de la Cañada # 158, Colonia Fuentes Sección

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION Valid To: May 31, 2019

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 J. A. KING & COMPANY, LLC 14200 South Lakes Drive Charlotte, NC 28273 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: August

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Pte. Ltd. Blk

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Reynosa, Tamaulipas, México C.P. 88787 0 (Hereinafter

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK PRESSURE Hydraulic Pressure (Gauge) Hewett Road Gapton Hall Industrial Estate Great Yarmouth Norfolk NR31 0NN Contact: Mr J Gunn Tel: +44

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 SIMCO ELECTRONICS (Ireland) Limited IDA Business & Technology Park Garrycastle, Dublin Rd Athlone Westmeath, Ireland

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:, Cd. Gustavo Díaz Ordaz, Tamaulipas 88400 (Hereinafter

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Transcat Charlotte 8334 Arrowridge Blvd.,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Technical Maintenance, Inc. 3000 Northwoods

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC South Lakes Drive Charlotte, NC Connie Foster Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC South Lakes Drive Charlotte, NC Connie Foster Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 14200 South Lakes Drive Charlotte, NC 28273 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 APTIV CONTRACT SERVICES. S. DE R. L. DE C. V. CALIBRATION LAB Mexico Technical Center Ave. Hermanos Escobar #5756 Cd. Juarez, Chihuahua C.P. 32310, Mexico Ricardo

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Reynosa, Tamaulipas, México. C.P. 88787 0 (Hereinafter

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI-NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI-NCSLI Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI-NCSLI Z540-1-1994 QUALITY CALIBRATION SERVICE, INC. 5515 S Westridge Dr. New Berlin, WI 53151 Martin Lukomski Phone: 414 256 8900 CALIBRATION Valid To:

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Productivity Quality, Inc./Advanced Inspection

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Scope of Accreditation For The Calibration Solution Inc. Calibration

Scope of Accreditation For The Calibration Solution Inc. Calibration Scope of Accreditation For The Solution Inc. 9865 North Alpine Road Machesney Park, IL 61115 Jeff Tratnik 815-877-0880 In recognition of a successful assessment to ISO/IEC 17025:2005 and ANSI/NCSL Z540.1:1994,

More information

Deutsche Akkreditierungsstelle GmbH. Scope of Accreditation D-K to DIN EN ISO/IEC 17025:2005

Deutsche Akkreditierungsstelle GmbH. Scope of Accreditation D-K to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH to DIN EN ISO/IEC 17025:2005 Period of validity: 30.01.2018 to 27.10.2021 Date of issue: 30.01.2018 Certificate bearer: Testo Industrial Services GmbH Gewerbestraße

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Cal Tec Process Management, LLC 1400 Grange

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that NQA & Conformity Assessment Laboratory 23B

More information

110 to 330 Ω/ Ω 20 mω 330 to 1.1 kω/0.001 Ω 20 mω. 110 to 330 kω/0.1 Ω 12.8 Ω. 33 to 110 kω/0.1 Ω 4.1 Ω

110 to 330 Ω/ Ω 20 mω 330 to 1.1 kω/0.001 Ω 20 mω. 110 to 330 kω/0.1 Ω 12.8 Ω. 33 to 110 kω/0.1 Ω 4.1 Ω IAS Accreditation Number Accredited Entity Address CL-178 Qatar Calibration Services WLL, (QCAL) QP West Services Area Ghuwairiya, St IR #1 Ras Laffan Doha, PO Box 16069, State of Qatar Shreenivasa T R,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT WARREN 27485 George Merrelli Drive Warren, MI 48092 Scott Gates Phone: 248 560 4021 Email: scott.gates@element.com CALIBRATION Valid until: December

More information

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013)

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration 5909 Breckenridge

More information

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 19

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 19 Calibration Laboratory Assessment Service CLAS Certificate Number 2000-03 Page 1 of 19 Transmation Canada nc. 916 Gateway Canada L7L 5K7 Contact: Robert Whittaker Tel (905) 632-5869 Toll Free (800) 897-0067

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that McCune s Instrument, Inc. 108 North Lee Street

More information