Advanced Paperless Recorder eco-graph a
|
|
- Howard Potter
- 5 years ago
- Views:
Transcription
1 Technical Information TI 097R/4/ae Advanced Paperless Recorder eco-graph a User friendly paperless recorder, for recording analog signals, counter values and quantities. Swift overview using the integrated signal analysis. Application The Advanced Paperless Recorder Eco-Graph A is a compact measured value acquisition system with continuous savings thanks to the lack of replacement pens and paper costs. Eco-Graph A records measured value processes, quantities, operating times, monitors set point violations and stores the data both internally and on diskette. A swift overview can be gained by using the integrated signal analysis giving intermediate, daily, monthly and yearly reports. The measured data can be read out, visualized and analyzed using the ReadWin 000 PC operating software. Unit and channel set-up can be done on the unit or using a PC. Ideally suited for the water/waste water market, the Eco-Graph A can also be used in all other industrial branches for recording/monitoring processes and sequences. Features and Benefits Electronic recording replaces pen and strip chart recorders, saves consumable costs Universal inputs measure most signal types for universal applications (mv, V, ma, RTD, TC) Digital inputs can be used as event inputs, operation time counters or impulse counters Quick set up and integrated operating manual provide fast commissioning, save set up time Flash memory ensures reliable archiving, kept safe even during power failure ReadWin 000 PC software package included with Eco-graph, saves software purchase costs Serial interface, Ethernet or modem communication Totalization (integration) of analog input signals as standard Minimum, maximum, average value recording Display of the last 7 analyses front end on unit Loop-power supply as an option ATEX (European) approval for Ex-Zone The Power of Know How
2 Function and system construction Measurement Principle: Electronic recording, plotting, analysis, and archiving of analog and digital input signals from measuring devices. Measurement System: All connected analog measurement points are measured in parallel every 0 ms. Galvanic isolation channel to channel is 00 V. Damping is presettable from 0 to seconds per analog input. System basic damping can be ignored. Data storage is done in the internal memory (power failure secure via FLASH technology) and in the integrated diskette drive. Long term storage of data is done in the PC whereby the data can be trasferred to the PC either by diskette or by using a serial interface. The ReadWin PC application software, provided free with the recorder, can configure the unit, display values real time, and display measured values. Input signals Current (ma) Current Range: 0 to 0 ma / 0. ma; linear/square ± 0 µa 4 to 0 ma / 0. ma; linear/square ± 0 µa -0 to 0 ma / 0. ma; linear ± 44 µa Load tension V Maximum 00 ma Voltage (mv) Voltage Range: 0 to 00 mv / mv; linear ± 80 µv 0 to 00 mv / mv; linear ± 40 µv 0 to V / mv; linear/square ± mv 0 to 0 V / mv; linear/square ± 0 mv - to V / mv; linear ± 0 mv -0 to 0 V / mv; linear ± 0 mv Input Impedance: > MΩ (MR < 00 mv) > 0 kω (MR 00 mv Resistance thermometer (RTD) Pt 00: -8 to 6 F / 7 F ± 0.8 K (/-wire) (-00 to 80 C / K) ± 0. K (4-wire) Pt 00 (linearization to JIS, -8 to 0 F / 7 F ± 0.8 K (/-wire) C604-8), (-00 to 60 C / K) ± 0. K (4-wire) Pt 00: -8 to 6 F / 7 F ± 0.8 K (/-wire) (-00 to 80 C / K) ± 0. K (4-wire) Pt 000: -8 to 6 F / 7 F ± 0.8 K (/-wire) (-00 to 80 C / K) ± 0. K (4-wire) Ni 00: -76 to 6 F / 7 F ± 0.4 K (/- wire) (-60 to 80 C / K) ± 0.4 K (4-wire) Connections: / or 4-wire circuits, shielded cable Cable Compensation: 0 Ω per cable Measurement Current: 00 µa Open or closed circuit monitoring: Indicates on display Thermocouples (TC) B (Pt0Rh-Pt6Rh): to 08 F / 900 F ± 0.% from 7 F (0 to 80 C / 00 K) (± 0.% from 400 C) E (NiCr-CuNi): -44 to 8 F / 80 F ± 0.% from - F (-70 to 000 C / 00 K) (± 0.% from -80 C) J (Fe-CuNi): -46 to 9 F / 80 F ± 0.% from -48 F (-0 to 00 C / 00 K) (± 0.% from -00 C) K (NiCr-Ni): -8 to 0 F / 80 F ± 0.% from - F (-00 to 7 C / 00 K) (± 0.% from -80 C) L (Fe-CuNi): -8 to 6 F / 80 F ± 0.% (-00 to 900 C / 00 K) (± 0.%) N (NiCrSi-NiSi): -44 to 7 F / 80 F ± 0.% from - F (-70 to 00 C / 00 K) (± 0.% from -80 C) R (PtRh-Pt): -8 to F / 900 F ± 0.% from F (-0 to 768 C / 00 K) (± 0.% from 0 C) S (Pt0Rh-Pt): -8 to F / 900 F ± 0.% from F (-0 to 768 C / 00 K) (± 0.% from 0 C) T (Cu-CuNi): -44 to 7 F / 80 F ± 0.% from -8 F (-70 to 400 C / 00 K) (± 0.% from -0 C) Thermocouples continued top of page.
3 Input signals (continued) Accuracy Thermocouples (TC), continued U (Cu-CuNi): -8 to F / 80 F ± 0.% from -8 F (-00 to 600 C / 00 K) (± 0.% from -0 C) W (WRe/WRe): to 499 F ± 0.% (0 to C) (± 0.%) W (WRe/W6Re): to 499 F ± 0.% (0 to C) (± 0.%) Measurement Current: 00 µa for open circuit monitoring Comparison Point: Comparison points CJC (to IEC 60 84) selectable - internal compensation of the terminal temperature - external,, 68,, 40, 8, 76 F (0, 0, 0, 60, 70, 80 C) Comparison Point Accuracy: ±.8 F (±.0K) (can be calibrated front end) Input Resistance: 900 kω Open Circuit Monitor: Cable open circuit indicates in the display Reference Conditions: Measurement Accuracy: Warm Up Time: Ambient Temp. Influence: Ambient temperature 77 F ± 9 F ( C ± C) Air humidity: ± 0% rh Refer to page /, input type > 0. hour 0.0%/K of FSD Electrical connections (terminal and socket layout) with optional loop-power supply RS 48 8 Cable R L R L = resistance 9 RxD/TxD() RxD/TxD( _ ) to 0 V 0% -% 48 to 6 Hz L N 4 to 48 VAC/VDC 0/48 to 6 Hz (~) (~) _ GND GND max. 0 V/ A HART AH B C Additional units Power Digital in (DI) >0 ms V - 4 VDC _ > ma _ GND N L L- L Rel. Rel. Rel. RS RS48 DI DI DI DI 4 0 k 0 k To PC: Cable with 9 pol. Sub-D plug RxD - GND - TxD - To PC: Cable with pol. Sub-D plug To modem: Cable with 9 pol. Sub-D socket 4 V / ma 4 V / ma 4 V / ma HART AH B C 4 CH CH Ethernet HART AH B C 4 CH D- E- D- E- D- E- On connecting channels 4-6, see terminal connections CH - -wire loop-power supply with HART - I Y 7 4 RS To modem: Cable with pol. Sub-D socket I - Y HART Commu- Box -wire loop-power supply without HART Analog inputs x x4 x x x - - a) > 00 mv - b) 00 mv - x x4 x x4 x x4 x x x x x x x x x 0 to 0 ma, 4 to 0 ma, /- 0 ma, (Volt drop < V, R i < 0 Ohm) a) 0 to V, 0 to 0 V, /- V, /- 0 V b) 0 to 00 mv, 0 to 00 mv B (Pt0Rh-Pt6Rh): to 08 F ( 0 to 80 C) E (NiCr-CuNi): -44 to 8 F (-70 to 000 C) J (Fe-CuNi): -46 to 9 F (-0 to 00 C) K (NiCr-Ni): -8 to 0 F (-00 to 7 C) L (Fe-CuNi): -8 to 6 F (-00 to 900 C) N (NiCrSi-NiSi): -44 to 7 F (-70 to 00 C) R (PtRh-Pt): -8 to F (-0 to 768 C) S (Pt0Rh-Pt): -8 to F (-0 to 768 C) T (Cu-CuNi): -44 to 7 F (-70 to 400 C) U (Cu-CuNi): -8 to F (-00 to 600 C) W (WRe/WRe): to 499 F (0 to C) W (WRe/W6Re): to 499 F (0 to C) x x4 x x x x x4 x x x Pt00: Pt00: Pt000: Ni00: -8 to 6 F (-00 to 80 C) -8 to 6 F (-00 to 80 C) -8 to 6 F (-00 to 80 C) -76 to 6 F (-60 to 80 C) Shielded
4 Power Supply Input Power: Standard, to 0 VAC; 0% -%; 48 to 6 Hz Low voltage, 4 to 48 VAC / VDC; 0%, -%; 0/48 to 6 Hz Power Consumption: VA Electrical Safety: EN 6 00-, protection class I; standard voltage, over voltage category II; low voltage, over voltage category III Application conditions Installation conditions Installation Angle: Usage angle to DIN 6 7, NL 90 ± 0 Installation Hints: General Terminal strips are keyed, screw terminals for cable size maximum AWG 4 (with ferrules) Panel mounted: Installation depth, approximately 8. (0 mm) including terminals Panel thickness, 0.08 to.7 ( to 40 mm) Attachment to DIN 4 84 Dimensions and Mounting Details, Panel Mounted.67" (44 mm).4" (8 mm).67" (44 mm).4" (8 mm) 8.7" (0 mm) Panel cut-out dimensions." (6 mm).0" (8 mm) Desk Top Version. (9 mm) 6.8 (7 mm) 7.40 (88 mm) 9.9 (6 mm) 9.6 (44 mm) 0.4 (64 mm) NEMA 4 (IP 6) Field Housing.6 (0 mm).6 (0 mm) 0.0 (4 mm) 4
5 Operating Conditions Ambient Temperature: Storage Temperature: Climatic Class: to 0 F (0 to 0 C) - to 60 F (-0 to 70 C), 0 to 7% rh, without condensation To IEC : B Ingress Protection: Front, NEMA (IP 4, EN 60 9, Cat. ) Rear, no protection, IP 0 (EN 60 9, Cat. ) Field housing, NEMA 4 (IP 6) Electromagnetic Immunity: EN 6 6- Compatibility: NAMUR recommendation NE : - ESD (electrostatic discharge), EN Level (6/8 kv) - Electromagnetic fields, EN , Level (0 V/m); additional deviation < 0.4% additional deviation on channel 4: % at approx. 460 mhz - Burst (fast transients), EN , Level (/ kv) - Surge on power cable, EN , kv asymmetrical, kv symmetrical - Surge on signal cable, EN , kv asymmetrical with external protection - HF cable fed, EN , 0 V, additional deviation < 0.% - 0 Hz magnetic fields EN , 0 A/m - Power failures EN , > 0 ms Normal Mode Noise 40 db on measurement range / 0 (0/60 Hz ± 0. Hz), at Rejection (EN 698-): voltage input Common Mode Noise Rejection (EN 698-): 80 db (0/60 Hz ± 0. Hz) at voltage input RF Protection: To EN 6 6, Class A (operation in industrial environment) Construction Operation and Display Material: Weight: Operating Elements: Display Elements: Display Modes: Real Time Clock: Remote Operation: Panel mount: Front bezel / door from die cast metal, matt chromed. Casing and rear panel, galvanized sheet steel. Desktop (portable): Unit is installed inside a varnished sheet steel housing. Wall mount: Unit is installed inside a hardened plastic NEMA 4 (IP 6) housing. Panel mount, approximately 7.7 pounds (. kg) Desk top version, approximately 4. pounds (6.4 kg) Selectable operation using 6 front mounted push buttons interactive with on screen dialog. Integrated operating manual (push button operation). QUICK set up: setting up date, time, feed rate. Selection of signal type, measurement type, engineering units and measurement range (per channel). Automatic signal recognition and setting. Color graphic with inch (6 mm) diagonal screen, 76,800 dots (0 x 40 pixel) Curves/sequences, curves in zones, digital display, event list (alarm conditions/power failures, condition display, historical display in curve plot form with display of the digital values, date and time). Switchable summer/normal time automatic. Buffer 4 years, at ambient temperature 9 to 77 F ( to C) Setting up and archiving unit parameters per diskette or using the rear mounted serial interface (only with the Digital I/O option, refer to option, page 6) RS (e.g. modem) or RS 48 with the ReadWin 000 PC software from EndressHauser Measurement storage Data Security: Selectable recording speeds ( Feed rate ) 0, 0., 0.4, 0.8,.,.4, 4.8, 0.0,.0, 4.0, 40.0 ft/h (0,, 0, 0, 0, 60, 0, 40, 00, 600, 000 mm/h) Buffer 0 years for program/measured value memory (flash memory, non volatile, internal memory 04 ksram or 048 ksram) Cyclic copy of measured data to -/ diskette for archiving.44 MB; resolution is dependent on the preset feed rate (refer to feed rate chart, top of page 6) Permanent storage of the preset unit parameters in the Flash memory (non volatile)
6 Measurement storage (con t) Comparison Feed Rate Function principle of the display and recording/storage: to Storage Interval: Data is stored in defined intervals, dependent on the selected feed rate (it is possible to define a different feed rate/storage interval in alarm conditions). Feed rate inch/h Feed rate mm/h Storage cycle in seconds Typical memory availability Conditions for the following table: - No alarm violations / event storage - No digital inputs Analog Feed rate Feed rate 0 Feed rate 60 Feed rate 0 Feed rate 000 Channels mm/h (4 min) mm/h ( min) mm/h (0 sec) mm/h (0 sec) mm/h ( sec) Internal memory 04 kb 6 days, h 90 days, 7 h 0 days, h days, h day, h 7 days, 8 h 4 days, 0 h 8 days, h 9 days, h h 6 6 days, h 4 days days, 8 h days, 0 h h Internal memory 048 kb 848 days, 0 h days, h 70 days, 6 h days, 8 h days, h 09 days, h 7 days, 6 h 4 days, 0 h days, h days, h 6 8 days, h 79 days, h 6 days, h days, 6 h day, 7 h Diskette,.44 MB 677 days, h 69 days, h 6 days, h 8 days, h days, 9 h 406 days, 9 h 0 days, 6 h days, h 6 days, h day, 6 h 6 4 days, h 6 days, h days, 4 h 0 days, 4 h day, h Options Digital I/O 4 Digital Inputs: To DIN 9 40: Logical 0 = - to V, Active with logical = to 0 V, maximum Hz, maximum V, input current approximately. ma Auxiliary Voltage Output: For powereing digital inputs with potential free contacts, 4 VDC maximum 0 ma, short circuit protected, unstabilized Relays: Changeover contact, max. 0 VAC / A, for alarm condition transmission, at desktop version: maximum 0 V eff / 60 VDC Serial Interfaces: Type (RS / RS 48) and unit address can be selected Maximum cable length using shielded cable: 0 ft ( m) for RS ; 80 ft (000 m) for RS 48, galvanically isolated from the system Loop-power supply Outputs: 4 V ± 0%, maximum ma (internal current limiter) Communication Resistance: The resistors for HART communication are built in (0Ω); mm diameter sockets Galvanic Isolation: 00 V test voltage to all other circuits Ethernet interface (in preparation) Ethernet Interface: Internal Ethernet interface 0BaseT, connectro type RJ4, shielded cable, allocation of the IP address in the Eco-Graph A setup menu Certificates CE Mark: ATEX: By attaching the CE mark, EndressHauser confirms that the instrument fulfills all the requirements of the relevant EC directives. EU-Richtlinie 94/9/EG IIG EEx np IIC T4 (option) 6
7 Accessories The following accessories are included with the shipped unit: Unit plug-on screw terminals for power supply and signal inputs Panel mounting jack screws, operating manual and ReadWin 000 software package for PC. Optional Accessories Order Code RS operating cable for PC connection RSGA-S RS interface cable for modem connection RSGA-S RS 48 <-> RS adapter set, with VAC power supply in compact housing, no galvanic isolation RSGA-S Connection kit for RS <-> RS 48 adapter set and RS modem RSGA-S4 Shielded signal cable shielded connection strip for channel unit RSGA-A Shielded signal cable shielded connection strip for 6 channel unit RSGA-A RS / Ethernet interface VAC for DIN top hat rail, including interface cable, approximately 6 ft ( m) RSGA-E RS 48 / Ethernet interface VAC for DIN top hat rail RSGA-E NEMA 4 (IP 6) field housing RSGA-H Lock retro-fitting kit, complete RSGA-LA Lock retro-fitting kit, neutral RSGA-LB RS / RS 48 adapter set for DIN top hat rail, 4 VDC supply voltage, including VAC power adapter with galvanic isolation and PC / modem interface cable RSGA-S7 Plug-on -pole terminal strip for power supply Plug-on -pole terminal strip for relays 009 Plug-on -pole terminal strip for analog input 00 Plug-on 6-pole terminal strip for digital inputs Ordering Information Paperless recorder Eco-Graph A RSG Signal Inputs universal inputs (mv, V, ma, RTD, TC) 6 6 universal inputs (mv, V, ma, RTD, TC) 8 universal inputs integrated loop-power supply Power Supply to 0 VAC 4 to 48 VAC / VDC Digital In/Outputs / Interface A Digital in/outputs / interface not required D Digital in/outputs not required / with Ethernet interface (in preparation, consult factory) E 4 impulse/count inputs, relays / RS /4848 interface F 4 impulse/count inputs, relays / Ethernet RS /48 interface (in preparation, consult factory) 4 Internal Memory / Recording Length A Memory for maximum MB / approximately 00 ft (0 m) recording length for channels B Memory for maximum MB / approximately 00 ft (60 m) recording length for channels C Factory calibration certificate / Memory for maximum MB D Factory calibration certificate / Memory for maximum MB Additional equipment Panel mounting,.7 x.7 (44 x 44 mm) front bezel, NEMA (IP 4) ingress protection Desk top housing, power cable with US plug Field housing, NEMA 4 (IP 6) 6 Operating version H American E Spanish 7 Model A Standard equipment without disk lock B Neutral version (without EH logo) C Standard equipment with disk lock D Neutral version (without E=H logo) with disk lock 8 Software A Standard software 9 Certification No certification A ATEX IIG EEx np IIC T4 without diskette drive 7
8 Supplemental documentation Eco-Graph A Operating manual BA R/09 ATEX Safety instructions XA 04R/09/a For application and selection assistance, in the U.S. call 888-ENDRESS For total support of your installed base, 4 hours a day, in the U.S. call Visit us on our web site, United States EndressHauser, Inc. 0 Endress Place Greenwood, IN 464 Phone: (7) ENDRESS FAX: (7) Canada EndressHauser Canada Ltd. 440 Graham s Lane Unit, Burlington ON, L7S W Phone: (90) FAX: (90) Mexico EndressHauser Paseo del Pedregal No. 60 Col. Jardines del Pedregal 0900, Mexico D.F. Mexico Phone: () FAX: () EndressHauser The Power of Know How TI 97R/4/ae/ EndressHauser, Inc.
Paperless Recorder PR20
Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological
More informationTemperature transmitter with local display RIT 261
Technical Information TI 091R/2/ae Temperature transmitter with local display RIT 261 Universal field mounted transmitter provides an exceptional backlit temperature indication with five large digits and
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationTemperature transmitter itemp RTD DIN rail TMT 127
Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,
More informationProcess display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
More informationTemperature head transmitter itemp PCP TMT 181
Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationitemp HART DIN rail TMT112
Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationitemp PA TMT184 Technical information
Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and
More informationTemperature head transmitter itemp TC TMT 188
Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More informationTemperature head transmitter itemp PCP TMT 181
Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationTechnical Information RMA42
TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationMultifunction Intelligent 4-wire Isolated Signal Conditioner
Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.
More informationPROGRAMMABLE FIELD TEMPERATURE TRANSMITTER
Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance
More informationTemperature Measurement
Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective
More informationLevel Limit Switch nivotester FTL 325 P
Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationâ Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)
Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into
More informationâ itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring
Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a
More informationv v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.
v v PMA Line recorder KS 3930 A KS 3930 B Galvanically isolated input channels for simple connection Measuring and recording range freely configurable Maintenance-free recording system Universal cassette
More informationDigital indicator for panel mounting With multi-function input Model DI25
Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationConductivity measurement SmarTec S CLD 132
Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationC520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters
C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationHART Compatible Intelligent 2-wire DIN Rail Transmitters
HART Compatible Intelligent 2-wire DIN Rail Transmitters MESO-L is a Smart and universal 2-wire DIN Rail transmitter for temperature and other measurement applications. MESO-LX is the Intrinsic Safe version
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationUniversal Intelligent 2-wire In-head Transmitters
Universal Intelligent 2-wire In-head Transmitters Actual size IPAQ-H is a universal and intelligent 2-wire In-head transmitter for temperature and other measurement applications. IPAQ-HX is the Intrinsic
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationFieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex
Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationHART field temperature transmitter Models TIF50, TIF52, TIF62
Electrical temperature measurement HART field temperature transmitter Models TIF50, TIF52, TIF62 WIKA data sheet TE 62.01 Applications Plant construction Process engineering General industrial applications
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationTechnical Information Barrier RB223
TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits
More informationTechnical Information RMS621
TI00092R/09/EN/14.16 71355039 Products Solutions Services Technical Information RMS621 Energy manager Steam and Heat Computer for Industrial Energy Calculation of Steam and Water Application Energy management
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationRail mounted Temperature Transmitter TH102/TH102-Ex
Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples
More informationSITRANS T measuring instruments for temperature
SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15
More informationHART Compatible Intelligent 2-wire In-head Transmitters
HART Compatible Intelligent 2-wire In-head Transmitters Actual size MESO-H is a Smart and universal 2-wire Inhead transmitter for temperature and other measurement applications. MESO-HX is the Intrinsic
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationMCR-T-UI(/NC) MCR-T-UI-E(/NC)
MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationDissolved Oxygen Measurement liquisys M COM 223 F / 253 F
Technical Information TI 246C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F Oxygen Controller Benefits at a glance Liquisys M COM 223 F Liquisys M COM 253 F Due to the modularity of its
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationph / ORP Measurement mypro CPM 431
Technical Information TI 173C/24/ae ph / ORP Measurement mypro CPM 431 Two-wire transmitter for ph and ORP with HART communication for use in hazardous or non-hazardous areas Areas of application The analysis
More informationTemperature measurement TMD 832 head transmitter
Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications
More informationPlug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs
Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationitemp HART TMT142 Technical Information
Technical Information itemp HART TMT142 Temperature transmitter for resistance thermometers, thermocouples, resistance transmitters and voltage transmitters, adjustable via HART protocol Application Temperature
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationDigital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version
Electrical temperature measurement Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version WIKA data sheet TE 32.04 Applications Process
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationPortable Multi-Channel Recorder Model DAS240-BAT
Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes
More informationC1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications
Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers
More informationTechnical Information itemp TMT180
TI00088R/09/EN/14.16 71315611 Technical Information itemp TMT180 Temperature head transmitter for resistance thermometers Pt100 Configurable using a PC, for installation in a terminal head, form B Application
More informationTT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H
Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More information02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
More informationRadar Level Measurement micropilot FMR 130 for stilling wells
Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationOPTITEMP TT 20 Technical Datasheet
OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationTemperature Measurement
Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationC4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors
C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More information02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
More informationAIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)
Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)
More informationTemperature Measurement
Siemens AG 017 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationDigital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel
Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel Digital-analogue meters of LEL-NA series with a multicolour bargraph have a universal input destined
More informationConductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16
Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationC series Product brief
Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1
More information