TRADE Prices Monday-Friday 7am-5pm. (HETAS Installers ONLY)
|
|
- Natalie Patterson
- 5 years ago
- Views:
Transcription
1 TRADE Prices 2017 (HETAS Installers ONLY) ex VAT Monday-Friday 7am-5pm
2 VITREOUS FLUE premium black enamel single skin flue pipe Straight Lengths V mm V mm V mm V5adj Adjustable length V5330d 330mm + door V5500d 500mm + door V51000d 1000mm + door V mm V mm V mm V6adj Adjustable length V6330d 330mm + door V6500d 500mm + door V61000d 1000mm + door Elbows, Tees, others parts V Elbow V545d 45 Elbow + door V Elbow V590t 90 Tee + Cap V5off 1 Piece Offset V5offd 1 Piece Offset + door V5ssadj 0-90 Adjustable Bend Stainless Steel V5brk Wall Bracket V5dmp Damper Unit V Increasing Adaptor V5rose Rosette Collar V5dd Damper door VCowl5 Cowl for vitreous pipe V Elbow V645d 45 Elbow + door V Elbow V690t 90 Tee + Cap V6off 1 Piece Offset V6offd 1 Piece Offset + door V6ssadj 0-90 Adjustable Bend Stainless Steel V6brk Wall Bracket V6dmp Damper Unit V Increasing Adaptor V " Increasing Adaptor V6con Continental Adaptor V6rose Rosette Collar V6dd Damper door VCowl6 Cowl for vitreous pipe 25 2
3 Flexi Liner Stainless Steel Liner - per metre flex5 316 grade flex grade flex6 316 grade flex grade Liner Fittings + Chimney Adaptors 5-5MA MA MR 5- MR MABF MA Bolt-Fix NC5 Nose Cone 6.67 TP5 Top Plate TC5 Top Clamp CowL5 Standard Cowl for Liner BG Birdguard (stainless) BGT Birdguard (terracotta) AIO5 All-In-One Cowl (stainless) AIOT5 All-In-One Cowl (terracotta) AIOAD5 All-In-One Anti-Down-Draught terracotta SA5 Sump Adaptor (external fit) CLAY Internal Clay Liner Adaptor for 7" clay CLAY Internal Clay Liner Adaptor for 8" clay CLAY Internal Clay Liner Adaptor for 9" clay JOIN Liner joiner MA MA MR 5- MR MABF MA Bolt-Fix NC6 Nose Cone 6.67 TP6 Top Plate TC6 Top Clamp CowL6 Standard Cowl for Liner BG Birdguard (stainless) BGT Birdguard (terracotta) AIO6 All-In-One Cowl (stainless) AIOT6 All-In-One Cowl (terracotta) AIOAD6 All-In-One Anti-Down-Draught terracotta SA6 Sump Adaptor (external fit) CLAY Internal Clay Liner Adaptor for 7" clay CLAY Internal Clay Liner Adaptor for 8" clay CLAY Internal Clay Liner Adaptor for 9" clay JOIN Liner joiner
4 Register Plate Kits (with brakets) 5REG8 400 x 800mm with hole REG8 400 x 800mm with hole REG x 1000mm with 4" hole REG x 1000mm with hole REG x 1000mm with hole REG x 1000mm with 7" hole REG x 1200mm with hole REG x 1200mm with hole REG x 1200mm BLANK REGWAH 400 x 1000mm 5/ with Access Hatch Installation and Aftercare CEM500 Fire Cement 500g tub 3.00 CEM1KG Fire Cement 1kg tub 4.00 CEMBLK Fire Cement tube Black 5.00 SILI High Temp Silicone 7.00 NPLT Notice Plate 3.99 NPLTX10 Notice Plate x VENT Air Vent for wall VENTMINI Mini Air Vent for wall COALRM C.O. Alarm THERMO Magnetic Thermometer 7.00 VERM100 Vermiculite Insulation 100L Bag PNTMAT Paint - Matt Black 9.00 PNTMET Paint - Metallic Black PNTCRM Paint - Ivory/Cream PNTCHR Paint - Charcoal PNTGRY Paint - Light Grey PNTRED Paint - Red GLASCL Stove Glass Cleaner - Spray 5.00 GLSDW Dry Wiper Glass Cleaner 5.00 FANP4 Stove Top Fan - 4 Blade ROP3 Stove Rope 3mm 1.50 ROP6 Stove Rope 6mm 2.00 ROP8 Stove Rope 8mm 2.50 ROP10 Stove Rope 10mm 3.00 ROP12 Stove Rope 12mm 3.20 FROP15 Flat Thermal Tape 15mm wide 3.20 FROP25 Flat Thermal Tape 25mm wide 4.00 ROPADH Rope adhesive
5 DINAK TWINWALL INSULATED FLUE Stainless Steel Silver Finish Straight Lengths mm Length mm Length mm Length mm Length mm Length mm Length mm Length mm Length Adjustable Lengths 022 Adjustable mm Adjustable mm Adjustable mm Adjustable mm Adjustable mm Adjustable mm Elbows Elbow Elbow Elbow Elbow Elbow Elbow Tees Tee Tee Tee Cap Tee Tee Tee Cap
6 Adaptors 5A16 5- Vitreous Adaptor A17 4- Vit Increasing Adaptor Q Upside-Down Adaptor DF Stack Support plate A16 6- Vitreous Adaptor A17 5- Vit Increasing Adaptor Q Upside-Down Adaptor DF Stack Support plate Cowls 5010 Rain Cap All-Weather Rain Cap Open Terminal Rain Cap All-Weather Rain Cap Open Terminal Locking Bands 5070 Locking Band Locking Band 3.39 Brackets / Supports 5082 Roof Support Joist Support Guy Wire Bracket Wall Support (fixed) Adjustable Wall Support mm Cuttable Wall Support mm Long Cuttable Wall Support mm FLAT Wall Support (fixed) FLAT Adjustable Wall Support mm FLAT Cuttable Wall Support mm FLAT Long Cuttable Wall Support mm Single Arm Support Adjustable Base Support (triangle sides) Roof Support Joist Support Guy Wire Bracket Wall Support (fixed) Adjustable Wall Support mm
7 6835 Cuttable Wall Support mm Long Cuttable Wall Support mm FLAT Wall Support (fixed) FLAT Adjustable Wall Support mm FLAT Cuttable Wall Support mm FLAT Long Cuttable Wall Support mm Single Arm Support Adjustable Base Support (triangle sides) Firestops / Trim Plates 5064 Solid Firestop Plate Vented Firestop Plate 2-part BFS Vented Firestop Plate 1-piece Finishing Plate Finishing Plate Circular Finishing Plate for angles Solid Firestop Plate Vented Firestop Plate 2-part BFS Vented Firestop Plate 1-piece Finishing Plate Finishing Plate Circular Finishing Plate for angles Storm Collars / Flashing / Other 513A Storm Collar Wall Sleeve PFLASH Profile Flashing (for flat / profiled roofs) AFLASH Angled Flashing (for tiled / slated roofs) A Storm Collar Wall Sleeve PFLASH Profile Flashing (for flat / profiled roofs) AFLASH Angled Flashing (for tiled / slated roofs)
8 BLACK Finish Straight Lengths 5020B 940mm Length B 440mm Length B 270mm Length B 140mm Length B 940mm Length B 440mm Length B 270mm Length B 140mm Length Adjustable Lengths 5022B Adjustable mm B Adjustable mm B Adjustable mm B Adjustable mm B Adjustable mm B Adjustable mm Elbows 5040B 45 Elbow B 30 Elbow B 90 Elbow B 45 Elbow B 30 Elbow B 90 Elbow Tees 5030B 135 Tee B 90 Tee B Tee Cap B 135 Tee B 90 Tee B Tee Cap Adaptors 5A16B 5- Vitreous Adaptor A17B 4- Vit Increasing Adaptor
9 6A16B 6- Vitreous Adaptor A17B 5- Vit Increasing Adaptor Cowls 5010B Rain Cap B All-Weather Rain Cap B Open Terminal B Rain Cap B All-Weather Rain Cap B Open Terminal Locking Bands 5070B Locking Band B Locking Band 4.41 Brackets / Supports 5082B Roof Support B Joist Support B Guy Wire Bracket B Wall Support (fixed) B Adjustable Wall Support mm B Cuttable Wall Support mm B Long Cuttable Wall Support mm B FLAT Wall Support (fixed) B FLAT Adjustable Wall Support mm B FLAT Cuttable Wall Support mm B FLAT Long Cuttable Wall Support mm B Single Arm Support B Adjustable Base Support (triangle sides) B Roof Support B Joist Support B Guy Wire Bracket B Wall Support (fixed) B Adjustable Wall Support mm B Cuttable Wall Support mm B Long Cuttable Wall Support mm B FLAT Wall Support (fixed) B FLAT Adjustable Wall Support mm
10 6836B FLAT Cuttable Wall Support mm B FLAT Long Cuttable Wall Support mm B Single Arm Support B Adjustable Base Support (triangle sides) Firestops / Trim Plates 5064B Solid Firestop Plate B Vented Firestop Plate 2-part BFSB Vented Firestop Plate 1-piece B Finishing Plate B Finishing Plate B Solid Firestop Plate B Vented Firestop Plate 2-part BFSB Vented Firestop Plate 1-piece B Finishing Plate B Finishing Plate Storm Collars / Flashing / Other 513AB Storm Collar B Wall Sleeve PFLASH Profile Flashing (for flat / profiled roofs) AFLASH Angled Flashing (for tiled / slated roofs) AB Storm Collar B Wall Sleeve PFLASH Profile Flashing (for flat / profiled roofs) AFLASH Angled Flashing (for tiled / slated roofs)
11 STOVES Saltfire ST Range (collection only) kW ST kW ST1 Vision kW ST kW ST kW ST kW ST-X kW ST-X kW ST-X Paint to order Grey, Charcoal, Red 45 Burnished Door (ST-X models only) 50 Stove delivery - palletised - mainland 35 England/Wales 11
12 12
Contemporary Collection
HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold
More informationContemporary Collection
HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49
More informationICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT
More informationU1500E Gas Fireplace
Model U1500E-NG U1500E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.5 W.C. (0.87 kpa) 10 W.C. (2.48 kpa) Manifold Pressure -
More information60/100 Concentric Flue System Parts
60/00 Concentric Flue System Parts MG88(MG85 m extended option) Std Concentric Flue 60/00 (Avanta Plus). Low profile bend (Avanta Plus). Telescopic terminal. Wall plates - ( x white) MG80 Vertical Terminal
More informationTYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.
TYPE "B" GAS VENT SD (sizes 3", 4", 5", 6", 7") INSTALLATION INSTRUCTIONS Type "B" Gas Vents are strictly for interior or enclosed exterior use or exterior use above a roof line. Read vent and appliance
More informationSolid Fuel Fires, Installation, Spares & Aftercare.
Solid Fuel Fires, Installation, Spares & Aftercare 2016-2017 Spares for Antique Fireplaces Solid Fuel Fire Spares Gas Fire Spares Stove Spares Installation & Aftercare Products www.capitalfireplaces.co.uk
More informationSolid Fuel Fires, Installation, Spares & Aftercare
Solid Fuel Fires, Installation, Spares & Aftercare Spares for Antique Fireplaces Solid Fuel Fire Spares Gas Fire Spares Stove Spares Installation & Aftercare Products www.capitalfireplaces.co.uk Stove
More informationSIMPLY SOME OF THE FINEST STOVES AVAILABLE
Carron stoves Few things in life give such simple pleasure as the warmth and character a real burning stove brings to a home. Both classic in design and extremely practical, a Carron stove is an efficient
More informationNever fill any required clearance space with insulation or any other building materials surrounding the chimney.
INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE
More informationPRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5" to 8" Diameter
PRODUT TLOGUE RIGID STINLESS STEEL HIMNEY LINER 5" to 8" Diameter Listed To: UL-S635, UL-S640 and UL 1777 Get the Selkirk dvantage... The tradition continues...selkirk is the original innovator of prefabricated
More informationINSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT
INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD 100mm SLOPING CEILING FLUE KIT THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F WARNING: TO ENSURE SAFETY
More informationSOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame
SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame INSTALLATION INSTRUCTIONS AND OPERATIONS Firebox Model SWK24 Frame Models SWKL24-LAGUNA (Figure 1) SWKS24-SANDIA SWKH24-HOPI
More informationECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS
ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS
More informationWOOD FIRE FLUE KIT AND ACCESSORIES MANUAL
WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL Masport Limited 1-37 Mt Wellington Highway Panmure Auckland 6 Ph: 09 571 1200 Fax: 09 571 5864 www.masport.com 2005 CONTENTS Ordering Information... Page 3 Freestanding
More information150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS
www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to
More informationSIMPLY SOME OF THE FINEST STOVES AVAILABLE
SIMPLY SOME OF THE FINEST STOVES AVAILABLE Gun Metal/Black Cast Iron Stove Shown (4.7kw) BHC301 Also available: Smoke Exempt Model (7.3kw) BHC101 Smoke Exempt Model (4.7kw) BHC501 Cream Enamel Cast Iron
More informationICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR
More informationIHP. Service Replacement Parts List. Legacy TM S260 T-Top Cat. No. H7887 Model Years: August Present
IHP Service Replacement Parts List Legacy TM S260 T-Top Cat. No. H7887 Model Years: August 1995 - Present Replaceable Metal Components Item No. Cat. No. Description ** H5570 Door Back w/handle (door gasket
More informationOur non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.
LockTab Feature for Type Gas Vent Our non-positional lock system on the Selkirk Gas Vent is the best lock system on the market today. The incorporation of the LockTab feature simply improves our lock system
More informationmanthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e
manthorpe building products Roll-Out Dry Fix Ridge System Fixing Instructions MBP 8265e Ridge Details Fig A. Assembly View of Dry Ridge Detail s/s screw clamping plate rubber washer foam spacer ridge tile
More informationCATALOG. Stainless Steel Flexible Chimney Liner
CATALOG Stainless Steel Flexible Chimney Liner Flex is the most premier and high performance Stainless Steel Chimney liner available. Specifications Flex Liner Material -.006 316 Stainless Steel Regular
More informationHEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING
HEARTH PRODUCTS KITS AND ACCESSORIES 750052M Rev. C 05/2014 VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING INSTALLATION INSTRUCTIONS FOR SECURE FLEX VERTICAL TERMINATION KITS (CATALOG NO. 56L74
More informationContemporary Collection
HZ4STE Gas Fireplace Model HZ4STE - NG1 HZ4STE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.49 kpa)
More informationINTERIOR DUCTWORK KIT
INTERIOR DUCTWORK KIT 90359DUC1 To be used with Omega National Products, LLC RHVBB30SS Blower 1. Install blower in metal liner ( sold separately ) following instructions provided. 2. Install charcoal filters
More informationWoodburning appliances price list
Woodburning appliances price list Front cover: Luna Diamond 1100 CR. Boley, Netherlands 1. Swipe 2. Driver (central unit). Motorunit with step engine (glass / sparkscreen / regulation combustion air supply)
More informationfor Flexi Sun Lite Planning the layout
for Flexi Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed
More informationWoodburning appliances price list
Woodburning appliances price list 1. Swipe 2. Driver (central unit). Motorunit with step engine (glass / sparkscreen / regulation combustion air supply) 4. Interface cables to motor 5. Temperature sensor
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions This symbol on the product means the product is listed by Underwriters Laboratories, Inc. AMERI-VENT MODEL 10 FB FACTORY-BUILT CHIMNEY These are the three ways to
More informationInstallation Instructions
Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77
More informationVERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS
VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS ROOM SEALED NON-CONDENSING COMBINATION/SYSTEM BOILERS AND WATER HEATERS 24i 47 311 37/38 9/14 CBi 41 311 50/51 28i 47 311 54 14/19 CBi 41 311 52/53
More information3. Remove the flue collar by backing out the two Phillips round head machine screws.
SERVICE MANUAL SERVICE PROCEDURES Defiant Non-Catalytic Model 1610 Woodstove **Wear gloves, a dust mask and protective eyewear when servicing a stove. ** Replacing the Fountain Assembly 1. Remove the doors,
More informationKiva Fireplace WOOD BURNING INSTALLATION MANUAL
18 24 30 Kiva Fireplace WOOD BURNING INSTALLATION MANUAL Frame Models: Orno Santa Fe Navajo Zuni Keep these instructions for future use. C This fireplace is to be installed ONLY by a construction industry
More informationDURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS
DURATECH 5"-8" DIAMETER INSTALLATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPOR- TANCE
More informationThe following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the
The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the Model 80 manual from the Stove Manuals section of our
More informationSTART HERE BEFORE YOU BEGIN FIG 1 STEP 2
PROFESSIONAL INSTALL RECOMMENDED REAR MODULAR / MULTI LED ROOF MOUNTS PART#: Z350040 / Z350050 REAR ROOF LED LIGHT MOUNTS Parts included (1) - Driver Side Roof Mount Upright (1) - Passenger Side Roof Mount
More informationSauna Barrel 2.5 M. health, beauty, peace of mind
Sauna Barrel 2.5 M health, beauty, peace of mind Specifications Wood Shape 2.5M LENGTH Ø1.9M WITH TERRACE WITHOUT TERRACE Spruce or thermo wood Round The internal volume of sauna room, m 3 4.69 6.04 Thickness
More informationSECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11
SECURE-TEMP ASHT + USA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING........... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS...2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART............. 3 GENERAL INSTALLATION
More informationTREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions
TREX ENHANCE RAILING (Also Applies to Trex Select Railing) NOTE: All Enhance Railing lengths are manufactured at CLEAR SPAN dimensions (spanning between space of posts): 7" for 6' clear span. Note that
More informationPARTS LIST FOR MODEL 7000 SERIES - 17/46
ITEM PARTS LIST FOR MODEL 7000 SERIES - 17/46 1 Rotor 3 Housing 1 4 End Plate 6 Drive End Cover 1 7 Free End Cover 1 8 Timing Gear Set 1 9 Bearing, Drive End 10 Bearing, Free End 1 Lip Seal, Viton 4 13
More informationDURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399
DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COM- BUSTIBLE MATERIALS. IT IS OF THE UTMOST
More informationLE7000 Provincial Built-in (Zero Clearance) Kit Instructions.
LE7000 Provincial Built-in (Zero Clearance) Kit Instructions. LE7000 Provincial ZC Kit contains: Part No. Quantity Description Picture 503259 4 Self Threading Screw 13mm 503459 6 Self Threading Screw Timbertites
More informationMIRAGE-X / BELLA. Shower Door Installation Instructions
MIRAGE-X / BELLA Shower Door Installation Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More informationEXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS
EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UPMOST
More information650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR CANADA TEMP/ GUARD 650 C TEMP/GUARD CHIMNEY SIZES 6-7 - 8 300ºC TEMP/GUARD CHIMNEY Listing No. MH 8251 Tested to UL103 HT / ULC-S629 / ULC-S604 / ULC-609 SIZES
More informationULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY
MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
More informationgabriel ash essential range
gabriel ash essential range Dear Customer, Please read ALL these instructions before assembly. The assembly of your new Essential greenhouse requires no technical knowledge. However it is important that
More informationAustin Standing Seam Awning Assembly and Installation Instructions. Assembly Instructions
Austin Standing Seam Awning Assembly and Installation Instructions Be sure to use safety glasses when assembling and installing the awning. Some metal parts may have sharp edges. Use work gloves to handle
More informationInstallation Instructions Student 101 Fume Cupboard
Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing
More informationFLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE
FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE Featuring our NEW 10-Groove Design Aluminum Kits now packaged in new Slim-Line Suitcase style Cartons. Easier to Carry Easier to Stock Easier to Ship MODEL SFCL
More informationMETRIC LIGHTNING PROTECTION PRODUCTS
Section 11 Metric Description... Page # 11.1 Taper Pointed Air Rods, Air Terminals & Attachments...270 11.2 Saddles & Attachments...271-272 11.3 s...273-275 11.4 Attachments...276-279 11.5 Clamps...280
More informationBuilding Instructions
Building Instructions Tools Required Tape measure Straight edge Pencil/pen Jigsaw Table Saw Circular Saw Electric drill 1 Hole saw bit Saw horses/table Protractor Staple gun Caulk gun Paint brush Wrenches
More informationTREX SELECT RAILING Installation Instructions
RAILING NOTE : All Trex Select Railing lengths are manufactured at ON CENTER dimensions (spanning from center of each post): 67-5/8" (76.8 cm) for 6' (.83 m) on center, and 9-5/8" (35.3 cm) for 8' (.44
More informationSpeedDeck. Fixing and Handling Guide
SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or
More informationCabonyx Installation Manual
Cabonyx Installation Manual Content Deck-Nyx and Plan-Nyx Installation Page 1 Flooring Products Page 1 Accessories Page 1 Installation Tools Page 2 Preparing Sub-structure Page 2 Installation Page 4 Cautions
More informationWALL SHELVING SYSTEM 250/750
468 2/7 Installation Example Ceiling Height (CH) : 2800 mm Ceiling Height (CH) : 28 mm Corner Installation 2 design panels are used to cover mm space in case of ceiling height 28 mm. Corner Example 469
More informationNISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS
NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS NOTES: 1. Before commencing, remove all wall liners and D Rings already installed in the vehicle. 2. Consult layout PDF and compare
More informationLife* Installation Instructions & User Care Instructions. (381kg) (60stone) (840lbs) (254kg) (40stone) (560lbs) (100kg) (220lb) (15stone)
Installation Instructions & User Care Instructions Trimmable Formers (381kg) (60stone) (840lbs) (254kg) (40stone) (560lbs) (100kg) (220lb) (15stone) i Installer- please read all instructions carefully
More informationfor Rigid Sun Lite Planning the layout
for Rigid Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed
More informationUniversal Installation Instructions. Preparation and Safety Information. Natural Lighting by Monodraught. Dust. Scaffolding
Natural Lighting by Monodraught Universal Installation Instructions Preparation and Safety Information Scaffolding For flat roofs and single storey buildings not exceeding 10 ft. ( m) in height, access
More informationkééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=
kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= Attic Insulation Shield must be installed when the chimney passes from a lower living space into an upper living space. R&B #3802-07(CR) Menards 6 8 20
More informationNanton Grain Mill Assembly
( 1 ) Nanton Grain Mill Assembly Locate package for assembling storage building. These are cut from 1/8 masonite. Inspect and lightly sand edges where it will be bonded. Use white glue or CA glue to bond.
More informationDura-Lock Roof System
DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.
More informationInterior CHAPTER 21. Phantom Roadster Instruction Manual 273
CHAPTER 21 Interior When you get to this chapter you are now starting on the finish that will make your car one that will be complete your hard work. This chapter will cover the installation of the door
More information-1- Coach Instructions.
-1- Coach Instructions. Insert the bogie pivot pins through the bottom of the coach body ensuring the dimples fit into the recesses. Glue the.06 x.25 short strips each side of the pivot head, bridge the
More informationOverview. Dimensions
Overview Completed for 5,110 (inc. VAT, delivery and installation) A treehouse on a small raised platform that leads onto a higher platform with activities and incorporates an existing tree. The treehouse
More informationgabriel ash essential range
gabriel ash essential range to be used in conjunction with the online assembly video found at www.gabrielash.com Certified Installers if required Thomas Hearn 07540 618852 Matthew Honeyborne 07977 788242
More informationInstalling Quick Mount PV Products on. Metal Shingle Roofs RESPECT THE ROOF
Installing Quick Mount PV Products on Metal Shingle Roofs RESPECT THE ROOF Getting Started Steel Shingle Roofing Flashing Method and Product Type Terminology Flashing QBase Mount Interlocking Steel Shingle
More informationInstallation Instructions for. Handrail Component System
Handrail STEP-BY-STEP Installation Instructions for Handrail Component System Rise in Inches Run in Inches 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 8.5 47 45 43 42 40 39 38 36 35 34 33 32
More informationINSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE
(125mm to 200mm dia.) INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE United Kingdom FACTORY- BUILT INSULATED CHIMNEY Tested for compliance with BS EN1856-1:2003 Product Designation T450 - N1 - D - Vm-L50045
More informationSIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"
1 1/2" x 60" Galvanized (thread both ends) Top Bolt See Detail "A-1" and Slotted Channel Parallel Conduit Clamp Warning Sign 3 Equal Bolt Spacings (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x
More informationPRICE LIST - 6th February 2017
W: www.cladco.co.uk E: info@cladco.co.uk T: 01837 659901 F: 01837 659902 Cladco Profiles North Road Industrial Estate, North Road, Okehampton, Devon, EX20 1BQ. PRICE LIST - 6th February 2017 Colour coated
More informationPLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING
Model TLC All-Fuel Chimney - 5" to 8" Factory-Built Type HT Insulated Chimney - Tested to UL103 PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING Type of Appliances Your Model TLC chimney is
More informationFLEX 48 x 72 / 60 x 72
FLEX 48 x 72 / 60 x 72 SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical
More informationSHEET METAL STUDENT GRADE RECORD Career & Technical Education
STUDENT GRADE RECORD Career & Technical Education Course Outline Modules Industry Module Test Industry Module Performance Module Competency Rating WINDHAM SCHOOL DISTRICT CORE 0. CTE Orientation 1. Basic
More informationSash Replacement Guide for Andersen Impact Resistant Casement Windows
Replacement Guide Replacement Guide for Andersen Impact Resistant Casement Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance
More informationESSENCE. Shower / Tub Door Installaion Instructions
ESSENCE Shower / Tub Door Installaion Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationVi - BOX GUTTER COMPONENT REFERENCE
Page 114 Vi - BOX GUTTER COMPONENT REFERENCE Item No Item Description Pack Comments BG1 Box Gutter D BG2 Box Gutter Braces A BG4 Box Gutter Sealing Tape A BG7 Box Gutter Internal Cladding D BG8 135 Box
More informationSmall Duct Systems. Product Catalogue. 1
Small Duct Systems Product Catalogue hvac@simx.co.nz www.smartvent.co.nz 1 Small Duct Systems The small duct system is different from a conventional system with the supply ductwork being smaller diameter
More informationDirective Systems & Engineering 2702 Rodgers Terrace Haymarket, VA
Directive Systems & Engineering 2702 Rodgers Terrace Haymarket, VA 20169-1628 www.directivesystems.com 703-754-3876 25 Element 7.4 wl. K1FO Designed Yagi, Model DSEFO432-25 ELECTRICAL SPECIFICATIONS Frequency
More informationGV Standard PitchVent
GV Standard PitchVent Installation Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings. 202-INST v1.0
More informationThe Leka System Installation Guide
Installation Guide The Leka System Installation Guide The following guide has been created to assist in the fabrication and installation of the Leka System. Please note that each roof is individual and
More informationProtech GM Accessories
Protech GM Accessories GROUND GAS PROTECTION Group Ground Gas Protection INTRODUCTION Both the British Standard BS8485:2015 and the CIRIA C735 guidance document emphasise the importance of on site verification
More informationVITREO X SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS
VITREO X SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationModel 209 Fireback Replacement
Model 209 Fireback Replacement Please read all the instructions before you begin the procedure. Confirm that you have all the necessary tools and materials. If you have any questions, technical support
More information6X3 Oscar Shed Assembly Manual
6X3 Oscar Shed Assembly Manual Revision #7 Jan 1st, 2017 Thank you for purchasing our 6x3 Oscar Storage Shed. Please take the time to identify all the parts prior to assembly. Please use Safety Eyewear
More informationHOW TO INSTALL HORIZONTAL ROD RAILING TREX SIGNATURE STANDARD
HOW TO INSTALL HORIZONTAL ROD RAILING NOTES:» Adjust drill power to lowest setting that will drive screw. DO NOT OVER TORQUE 6 STAINLESS STEEL STAINLESS FASTENERS.» NEVER use impact tools on 6 Stainless
More informationRight On Replicas, LLC Step-by-Step Review * 1959 Chevy Impala Hard Top 2 n 1 1:25 Scale Revell Model Kit # Review
Right On Replicas, LLC Step-by-Step Review 20140915* 1959 Chevy Impala Hard Top 2 n 1 1:25 Scale Revell Model Kit #85-4315 Review Review and Photos by James Yeager 1959 Chevy was the second year of production
More informationFACTORY BUILT INSULATED CHIMNEY
& INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (CANADA & UNITED STATES) FACTORY BUILT INSULATED CHIMNEY LISTED Tested to UL03 Type HT LISTED Tested to ULC-S604 ULC-S60 A MAJOR CAUSE OF CHIMNEY RELATED
More informationThe SolarSheat 1500G/1500GS/1501GS Flush Roof Mount Installation Manual By Your Solar Home, Inc.
The SolarSheat 1500G/1500GS/1501GS Flush Roof Mount Installation Manual By Your Solar Home, Inc. Version 1.0 December 28, 2006 All building, plumbing, electrical, and safety codes supersede the instructions
More informationGlass Curtain Wall. 1. Point Supported Glass Curtain Wall 2. Exposed-Frame Glass Curtain Wall 3. Hidden-Frame Glass Curtain Wall
Glass Curtain Wall 1. Point Supported Glass Curtain Wall 2. Exposed-Frame Glass Curtain Wall 3. Hidden-Frame Glass Curtain Wall Project case Point Supported Glass Curtain wall is made by glass panel, point
More informationinstallation instructions
installation instructions Easi-Plan WC Frame 820mm with Dual Flush Cistern ref: EPWC-05-1005 Easi-Plan WC Frame 980mm with Dual Flush Cistern ref: EPWC-05-1505 EASI-PLAN installation instructions Parts
More informationTrunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available
Trunking Guide Colour List... W White M Magnolia B Black A Aluminium O Oak Effect R Red P Premium Wood (stainable 22x22 only) F1 Light Oak Effect (22x22 only) illustrations not to scale shape & size (wxh)
More informationTREX SELECT RAILING. Installation Instructions PARTS
RAILING NOTE : All Trex Select Railing lengths are manufactured at ON CENTER dimensions (spanning from center of each post): 67-5/8" (76.8 cm) for 6' (.83 m) on center, and 9-5/8" (35.3 cm) for 8' (.44
More informationFENDER FLARE INSTALLATION
Part#: TG-FF8G4158 FOR 2007-2013 GMC Sierra 1500 Pickup Truck (Exclude 69.3inch Short Bed Models) FENDER FLARE INSTALLATION Hardware Kit Included IMPORTANT TYGER only approves the installation according
More informationSAFETY. Read and understand all safety precautions and instructions before installing this product.
SAFETY Your safety and the safety of others is very important. In order to help you make informed decisions about safety, we have provided installation instructions and other information. These instructions
More informationCAPX Installation Print 4/10/ CAB ASSEMBLY Part Pos Description Quantity Foot Notes CAB SECTION PLATE, MO
CAPX Installation Print 4/10/2019 6245100014 CAB ASSEMBLY Part Pos Description Quantity Foot Notes 6245100008 1 CAB SECTION 1 + 6705100023 2 PLATE, MOUNTING 1 6705012439 3 PLATE, MOUNTING 1 6326100000
More informationFLEX SHOWER DOOR INSTALLATION INSTRUCTIONS
FLEX SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings, manuals
More informationTaco Bell Restaurant kit in HO scale
Taco Bell Restaurant kit in HO scale Parking lot base and cars not included This kit includes all building parts milled in white styrene plastic, clear window glazing, Plastruct tile roofing, and logo
More informationInstallation instructions for heating engineers. Vitosol 200 Type D10, D20 and D30 Direct flow vacuum tube collector VITOSOL 200
Installation instructions for heating engineers Vitosol 200 Type D10, D20 and D30 Direct flow vacuum tube collector VITOSOL 200 4/2004 Safety instructions Please follow these safety instructions closely
More information