60/100 Concentric Flue System Parts

Size: px
Start display at page:

Download "60/100 Concentric Flue System Parts"

Transcription

1

2 60/00 Concentric Flue System Parts MG88(MG85 m extended option) Std Concentric Flue 60/00 (Avanta Plus). Low profile bend (Avanta Plus). Telescopic terminal. Wall plates - ( x white) MG80 Vertical Terminal 60/00 (Avanta Plus). Vertical terminal. Boiler connector. Wall bracket MG89 Std Concentric Flue 60/00 (Avanta /8/4v). Boiler bend (Avanta /8/4v). Telescopic terminal. Wall plates - ( x white) MG885 Vertical Terminal 60/00 (Avanta /8/4v). Vertical terminal. Wall bracket

3 MG8790 Roof flashing (0 to 45 pitched) MG877 Roof flashing (flat) MG86-50mm MG87-500mm MG88-000mm Flue Extension Piece (cannot be cut) c/w Clamp MG to 5mm Flue extension piece (adjustable) c/w Clamp MG84-500mm MG84-000mm Flue Extension Piece (cuttable) c/w Clamp MG Bend c/w Clamp (single seal) MG Bend c/w Clamp (single seal)

4 Wall Plate See table for part Nos. MG8 LP Bend + adaptor plate (Avanta Plus) 654 LP adaptor plate (Avanta Plus) -supplied as standard with boiler- S6768 Boiler connector (Avanta Plus) - for vertical outlet supplied as standard with Part No. MG80 Vertical flue kit (Avanta Plus) - MG84 60/00mm Concentric Flue Spare Parts(not all illustrated) Part No Description 654 LP adaptor plate (Avanta Plus) MG78 Air inlet seal for LP boiler bend (flue side) MG87650 Clamp MG8770 Wall bracket 00mm MG745 Air inlet seal for Avanta 8v boiler bend MG8500 Wall plate - Black MG7568 Wall Plate - White 4

5 Avanta Plus 60/00mm Concentric Flue System 00 MG88 Std Concentric Flue 60/00 ( Avanta Plus) installed C/L of Terminal 98 Core Drill Wall - 5mm Dia.. Low profile bend (Avanta Plus). Telescopic terminal. Wall plates ( white) Top of boiler Wall Depth Max 450mm - Min 50mm.5 Terminal is telescopic NOTE: If the wall depth is less than 50mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 50mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 0mm longer than the outer MG80 - Vertical Flue (Avanta Plus) Installed in Pitched Roof 0 o/d Min Hole in Roof 760± ±0 To inside of weather collar To suit site 0 99 o/d Pitch 0 to 45 Weather collar detail 805 ±0 to inside weather collar 0 65 ±0 to roof level 0 o/d Min Hole in roof 99 o/d To suit site MG80 - Vertical Flue (Avanta Plus) Installed in Flat Roof 5

6 Avanta /8/4ov 60/00mm Concentric Flue System C/L of Terminal Core Drill Wall - 5mm Dia. MG89 Std Concentric Flue 60/00 ( Avanta ov) installed 64 Top of boiler.5 Wall Depth Max 450mm - Min 50mm Terminal is telescopic. Boiler bend (Avanta ov). Telescopic terminal. Wall plates ( white) NOTE: If the wall depth is less than 50mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 50mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 0mm longer than the outer MG885 - Vertical Flue (Avanta /8/4ov) Installed in Pitched Roof 45 0 o/d Min Hole in Roof 760±0 5 Weather collar detail 65 ±0 to roof level 805±0 To inside of weather collar 0 Pitch 0 to o/d 805 ±0 to inside weather collar 0 o/d Min Hole in roof 99 o/d 0 6 MG885 - Vertical Flue (Avanta /8/4ov) Installed on Flat Roof

7 Avanta Plus 60/00mm Plume Management Kits MG8 PMK-Horizontal Terminal Kit (Avanta Plus). PMK Wall terminal. LP boiler bend (Avanta Plus). Wall plates ( white and black) mm flue extension (60mm) 5. Support bracket (60mm) bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be installed with the outlet pointing vertically upwards PMK Horizontal Terminal Kit installed C/L of Terminal.5 00 Wall Depth - Max 550mm - Min 50mm Terminal inner and outer can be cut to suit- Note: Maintain the 0mm difference Core Drill Wall - 5mm Dia. Max 00mm - Min 50mm Note: Can be extended with extra parts 98 Top of boiler 7

8 Avanta Plus 60/00mm Plume Management Kits MG8 + MG85 PMK-Horizontal Terminal Kit (Avanta Plus). PMK Wall terminal. LP boiler bend (Avanta Plus). Wall plates ( white and black) mm flue extension (60) 5. Support bracket (60) 6. Vertical outlet NOTE: The horizontal terminal unit must be installed with the outlet pointing vertically upwards The vertical outlet replaces the 90 bend, flue outlet and bird guard which are discarded PMK Horizontal Terminal Kit with a vertical outlet installed Roof level 00.5 Wall Depth - Max 550mm - Min 50mm Terminal inner and outer can be cut to suit- Note: Maintain the 0mm difference Standard Terminal Max 000mm - Min 50mm Note: Can be extended with extra parts C/L of Terminal Core Drill Wall - 5mm Dia. 98 Top of boiler 8

9 Avanta /8/4ov 60/00mm Plume Management Kits MG80 PMK-Horizontal Terminal Kit (Avanta ov). PMK Wall terminal. Boiler bend (Avanta ov). Wall plates ( white and black) mm flue extension (60mm) 5. Support bracket (60mm) bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be installed with the outlet pointing vertically upwards PMK Horizontal Terminal Kit (Avanta /8/4ov) installed C/L of Terminal 00.5 Wall Depth - Max 550mm - Min 50mm Terminal inner and outer can be cut to suit- Note: Maintain the 0mm difference Core Drill Wall - 5mm Dia. Max 00mm - Min 50mm Note: Can be extended with extra parts 64 Top of boiler flue outlet 9

10 Avanta /8/4ov 60/00mm Plume Management Kits MG80 + MG85 PMK-Horizontal Terminal Kit (Avanta OV). PMK Wall terminal. LP boiler bend (Avanta OV). Wall plates ( white and black) mm flue extension (60mm) 5. Support bracket (60mm) 6. Vertical outlet 6 4 NOTE: The horizontal terminal unit must be installed with the outlet pointing vertically upwards The vertical outlet replaces the 90 bend, flue outlet and bird guard which is discarded. 5 PMK Horizontal Terminal (Avanta /8/4ov) with a vertical outlet installed Roof level 00.5 Wall Depth - Max 550mm - Min 50mm Terminal inner and outer can be cut to suit- Note: Maintain the 0mm difference Standard Terminal Max 000mm - Min 50mm Note: Can be extended with extra parts C/L of Terminal Core Drill Wall - 5mm Dia Top of boiler flue outlet

11 Avanta Plus 60/00mm PMK Balcony Terminal Kit MG8 PMK Balcony Flue 60/00mm(Avanta Plus). PMK Balcony terminal. LP Boiler bend (Avanta Plus). Wall plates ( white and black) 4. Two 000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line) PMK Balcony Flue 60/00 (Avanta Plus) installed for a M overhang Core Drill Wall - 5mm Dia. Balcony.5 00 C/L of Terminal 98 Top of boiler Wall Depth - Max 550mm -Min - 50mm Terminal can be cut to suit Standard Balcony Kit for up to M One additional length allowed up to a Max of M Note: the extension kit must be graded back to the Terminal at approx to allow condensate to drain to boiler

12 Avanta /8/4ov 60/00mm PMK Balcony Terminal Kit MG8 PMK Balcony Flue 60/00mm (Avanta ov). PMK Balcony terminal. Boiler bend (Avanta ov). Wall plates ( white and black) 4. Two 000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line) PMK Balcony Flue 60/00mm (Avanta ov) installed for a M overhang Core Drill Wall - 5mm Dia. Balcony.5 00 C/L of Terminal 64 Standard Balcony Kit for up to M overhang One additional length allowed up to a Max of M Top of boiler Wall Depth - Max 700mm - Min 50mm Terminal can be cut to suit Note: the extension kit must be graded back to the Terminal at approx to allow condensate to drain to boiler

13 60/00 Plume Management Spare Parts MG80 PMK-Horizontal Terminal only MG8 PMK-Balcony Terminal only MG849 PMK-90 Bend + horizontal outlet c/w bird guard (60) MG8 PMK-Horizontal outlet (60) MG8 PMK-90 Bend (60) MG8 PMK-45 Bend (60) MG84 PMK 000mm Flue Extension piece c/w wall bracket (60) MG85 PMK-Wall bracket (60) not illustrated MG85 PMK-Vertical outlet terminal (60) MG8 PMK-45 Angle deflector (60) for use with Std Wall Terminal Kits (MG88 and MG89) only

14

15

16

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS ROOM SEALED NON-CONDENSING COMBINATION/SYSTEM BOILERS AND WATER HEATERS 24i 47 311 37/38 9/14 CBi 41 311 50/51 28i 47 311 54 14/19 CBi 41 311 52/53

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT

More information

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING HEARTH PRODUCTS KITS AND ACCESSORIES 750052M Rev. C 05/2014 VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING INSTALLATION INSTRUCTIONS FOR SECURE FLEX VERTICAL TERMINATION KITS (CATALOG NO. 56L74

More information

Contemporary Collection

Contemporary Collection HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold

More information

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases equipment catalog 3-5 Bases Adhesive Bases Used for mounting on membrane or built-up roofs. Mounted with adhesive or plastic roofing cement. The cast base has a mechanical conductor connector. BS-C-3/8ID-ADH-AT

More information

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Attached Flange & Double Barrier System FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW)

More information

TREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions

TREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions TREX ENHANCE RAILING (Also Applies to Trex Select Railing) NOTE: All Enhance Railing lengths are manufactured at CLEAR SPAN dimensions (spanning between space of posts): 7" for 6' clear span. Note that

More information

Installation Instructions Student 101 Fume Cupboard

Installation Instructions Student 101 Fume Cupboard Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing

More information

Rheem Room Sealed Kit - Installation Instructions. Installation must be carried out by a licenced plumber

Rheem Room Sealed Kit - Installation Instructions. Installation must be carried out by a licenced plumber Rheem 631275 Room Sealed Kit - Installation Instructions Installation must be carried out by a licenced plumber General The Rheem Room Sealed Balanced Flue Kit is designed to connect to a 631275 heavy

More information

Thermostat Conversion Kit Data Sheet CHOICE OF INSTALLATION

Thermostat Conversion Kit Data Sheet CHOICE OF INSTALLATION 22-022 Thermostat Conversion Kit Data Sheet The Thermostat Conversion Kit was designed and packaged with the serviceman in mind. It allows a quick and easy replacement of competitive devices with a new

More information

Accentra 52i Pellet Insert Zero Clearance Cabinet Part #

Accentra 52i Pellet Insert Zero Clearance Cabinet Part # Accentra 52i Pellet Insert Zero Clearance Cabinet Accentra 52i Pellet Insert ZC Cabinet Accentra 52i Pellet Insert Mounting Frame Accentra 52i Pellet Insert www.harmanstoves.com R:\Todd\Instruction Sheets_3-89-574323_RevC

More information

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

ECOVENT USA CHIMNEY MODEL EV-SHT 5-8 DIAMETER INSTALLATION INSTRUCTIONS ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS

More information

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD 100mm SLOPING CEILING FLUE KIT THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F WARNING: TO ENSURE SAFETY

More information

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to

More information

TREX SELECT RAILING Installation Instructions

TREX SELECT RAILING Installation Instructions RAILING NOTE : All Trex Select Railing lengths are manufactured at ON CENTER dimensions (spanning from center of each post): 67-5/8" (76.8 cm) for 6' (.83 m) on center, and 9-5/8" (35.3 cm) for 8' (.44

More information

TREX SELECT RAILING. Installation Instructions PARTS

TREX SELECT RAILING. Installation Instructions PARTS RAILING NOTE : All Trex Select Railing lengths are manufactured at ON CENTER dimensions (spanning from center of each post): 67-5/8" (76.8 cm) for 6' (.83 m) on center, and 9-5/8" (35.3 cm) for 8' (.44

More information

INSTALLATION AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER INSTALLATION RAINWATER PRODUCT GUIDE

INSTALLATION AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER INSTALLATION RAINWATER PRODUCT GUIDE AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER HANDLING Brett Martin Rainwater systems are light in weight and are therefore easy to handle. As with all other quality materials, Rainwater components

More information

Regency Bellavista B41XT-1 Gas Fireplace

Regency Bellavista B41XT-1 Gas Fireplace Regency ellavista 1XT-1 Gas Fireplace Specifications: Model 1XT-NG 1XT-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5

More information

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

TYPE B GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney. TYPE "B" GAS VENT SD (sizes 3", 4", 5", 6", 7") INSTALLATION INSTRUCTIONS Type "B" Gas Vents are strictly for interior or enclosed exterior use or exterior use above a roof line. Read vent and appliance

More information

INSTALL GUTTERING. 2 - Planning the work. Care is needed in setting out the guttering accurately, but actually fitting it is relatively easy.

INSTALL GUTTERING. 2 - Planning the work. Care is needed in setting out the guttering accurately, but actually fitting it is relatively easy. INSTALL GUTTERING Care is needed in setting out the guttering accurately, but actually fitting it is relatively easy. Before you climb a ladder, make sure it is stable and fixed securely to the structure

More information

Vertical Offset Base and Safety Rail System Installation Instructions

Vertical Offset Base and Safety Rail System Installation Instructions Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat

More information

C70 Window Roller Repair Taken from: Heres the problem:

C70 Window Roller Repair Taken from:  Heres the problem: C70 Window Roller Repair Taken from: http://www.volvospeed.com/vs_forum/topic/115086-how-to-c70-window-rollers-permanent-fix/ Heres the problem: This happened to two separate window assemblys on my c70

More information

Boat Lift Canopy Frame Assembly Instructions

Boat Lift Canopy Frame Assembly Instructions Patriot Docks Boat Lift Canopy Frame Assembly Instructions Helpful Tips: Assembling and installing the canopy frame and cover is a two person job. Additional help makes installation easier and is recommended.

More information

Pipe Product Catalog Table of Contents

Pipe Product Catalog Table of Contents Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"

More information

1LG WALL MOUNTS - 1LG

1LG WALL MOUNTS - 1LG WM WALL MOUNTS - 1LG 1LG The Universal One-Legged Mount (1LG) may be the one and only mount that can be installed on any part of any building. This mount is designed for many types of antennas home, TV,

More information

MODULAR HIGH TUNNEL INSTALLATION GUIDE

MODULAR HIGH TUNNEL INSTALLATION GUIDE 9615 Grandview Rd. Kansas City, MO 64137 Version: 15 JAN -2015 Sustainable Agriculture Solutions MODULAR HIGH TUNNEL INSTALLATION GUIDE (816) 444-7330 SmallFarmTools.com Thank you for purchasing a Modular

More information

U1500E Gas Fireplace

U1500E Gas Fireplace Model U1500E-NG U1500E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.5 W.C. (0.87 kpa) 10 W.C. (2.48 kpa) Manifold Pressure -

More information

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2 911404-00 Concealed Vertical Rod Exit Device 33/3547A Installation Instructions Devices covered by these instructions: 33/3547A and 33/3548A Concealed Vertical Rod Exit Device 33/3547A-F and 33/3548A-F

More information

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni Bracket guide LK Radiator fixture Uni LK Radiator fixture Uni c/c 40 (Article no. 481 43 92) LK Radiator fixture Uni c/c 50 (Article no. 481 44 03) LK Pipe Pole (Article no. 481 43 91, 481 43 90) Used

More information

Concealed Thru-Roof Assemblies

Concealed Thru-Roof Assemblies Concealed Thru-Roof Assemblies IPC s concealed thru-roof assembly is ideal for new constructions or applications where installation will be concealed. The 240 assembly includes everything necessary for

More information

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools... INS-88.300-0A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Verify Curb Installation... 2 2. Required Installation Tools... 2 3. Unpacking the KSR... 3 4. Attach KSR Bottom Rail to Curb... 5 5. Attach

More information

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS GARDEN SHED Assembly Instructions Suitable for Models 6' Wide 8' Wide 0' Wide WITH VARYING DEPTHS GI0003 November 0 INSTALLATION ADVICE It's Not That Difficult! The construction of your shed isn't as complicated

More information

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent. LockTab Feature for Type Gas Vent Our non-positional lock system on the Selkirk Gas Vent is the best lock system on the market today. The incorporation of the LockTab feature simply improves our lock system

More information

This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format.

This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format. 1.00 - Introduction This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format. Please note, each roof has been individually designed to meet specific

More information

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# ) Compatibility ProBuilder Series CoolSmart TV ProBuilder Series Linear Fireplaces (42PB, 54PB & 72PB) Packing List Convection Manifold (with grill and mounting brackets pre-attached) 5 Diameter Aluminum

More information

Installation Guide Simplicity Alfresco. V1.9 Lu070318

Installation Guide Simplicity Alfresco. V1.9 Lu070318 0333 305 5272 www.canoports.co.uk Installation Guide Simplicity Alfresco V1.9 Lu070318 Tools Required Below is a list of tools that you will require to install your the Simplicity Alfresco System. Cordless

More information

TRADE Prices Monday-Friday 7am-5pm. (HETAS Installers ONLY)

TRADE Prices Monday-Friday 7am-5pm. (HETAS Installers ONLY) TRADE Prices 2017 (HETAS Installers ONLY) ex VAT sales@saltfire.co.uk 01929 555211 Monday-Friday 7am-5pm VITREOUS FLUE premium black enamel single skin flue pipe Straight Lengths V5250 250mm 11.99 V5500

More information

NEW equinox INSTALLATION GUIDE Issue

NEW equinox INSTALLATION GUIDE Issue NEW equinox INSTALLATION GUIDE Issue 2 CONTENTS 1. Preparing the ring beam 2 2. Installing the framework 3 3. How to install structural support posts 7 4. Insulation and waterproofing 8 5. Tile application:

More information

CAPTUR COMPONENTS. We make food look better.

CAPTUR COMPONENTS. We make food look better. CAPTUR COMPONENTS TOP EDGE GLASS CONNECTORS GCA6 6mm (1/4") Glass GCA10 10mm (3/8") Glass 2.76 2.90 2.76 2.90 TOP BOTTOM 1.13 1.13 6mm GLASS GC906 6mm (1/4") Glass 10mm GLASS GC9010 10mm (3/8") Glass Adjustable

More information

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# ) Compatibility ProBuilder Linear CoolSmart TV ProBuilder Series Linear Fireplaces (42PB, 54PB & 72PB) Packing List Convection Manifold (with grill and mounting brackets pre-attached) 5 Diameter Aluminum

More information

CountryAccents Pergola Assembly Instructions

CountryAccents Pergola Assembly Instructions CountryAccents Pergola Assembly Instructions Options 11 2" Squares Lattice Railing Gingerbread Scroll (For 5" Posts Only) Site Preparation Site preparation for either the round column or the 5" post pergola

More information

RBP-1215B-RX DODGE RAM QUAD CAB RX3

RBP-1215B-RX DODGE RAM QUAD CAB RX3 RBP-1215B-RX3 2002-2017 DODGE RAM 15-3500 QUAD CAB RX3 Passenger side RX-3 Side Step Drill Template Passenger side rear Modular Bracket (6) L Support Brackets Driver side rear Modular Bracket Driver side

More information

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney. INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS NOTE: Bolts should remain hand tight until all bolts are installed. STEP 1 Installing the door base (both sides). 1. Locate the outer, roll cage, mounting bolt (passenger side is shown in the illustration).

More information

GROWING BETTER THROUGH DESIGN LEAN-TO. Lean-To. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN LEAN-TO. Lean-To. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN Lean-To LEAN-TO Assembly Instructions 04/02 2 Lean-To Greenhouse Base Plan Introduction / Tools / Contents This is a copy of our Lean-To greenhouse base plan. Dimensions shown

More information

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE C Series Cool Surface System FRONT VENT [50-3463] INSTRUCTION MANUAL 4001609 This Cool Surface System has been tested for compliance to Standards: ANSI

More information

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device 911402-00 Rim Exit Device 33/35A Series Installation Instructions Devices covered by these instructions: 33/35A Rim Exit Device CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

More information

GREENHOUSE 6'x8' ASSEMBLY INSTRUCTIONS. (Internal Dimensions) Overall Dimensions (Approx.) L 193 W 200 H cms 97.5" L 76" W 78.

GREENHOUSE 6'x8' ASSEMBLY INSTRUCTIONS. (Internal Dimensions) Overall Dimensions (Approx.) L 193 W 200 H cms 97.5 L 76 W 78. ASSEMBLY INSTRUCTIONS GREENHOUSE 'x8' (Internal Dimensions) Overall Dimensions (Approx.) 7. L 9 W 00 H cms 97." L 7" W 78.8" H 0 IMPORTANT You must read these instructions carefully before you start to

More information

REGENCY TIMBER BUILDINGS

REGENCY TIMBER BUILDINGS REGENCY TIMBER BUILDINGS TEL 01948 830460 UNIT 22 PENLEY IND EST, PENLEY.WREXHAM. LL13 0LQ 1 Garage fitting instructions Tools needed handsaw, hammer, Stanley knife with hook blade, tape measure, battery

More information

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device *911403-00* 911403-00 Surface Vertical Rod Exit Device 33/3527A Installation Instructions Devices covered by these instructions: 33/3527A Surface Vertical Rod Exit Device 33/3527A-F (Fire) Surface Vertical

More information

PEAKED ROOF w/ inner cover underneath. Telescoping Outer Covers. p.1

PEAKED ROOF w/ inner cover underneath. Telescoping Outer Covers. p.1 PEAKED ROOF w/ inner cover underneath Telescoping Outer Covers p.1 HIVE FRAMES - STEP 2 Our new wedge-top frames come with an optional, insertable wedge comb guide to make your frames foundationless or

More information

Shed Assembly Instructions

Shed Assembly Instructions Shed Kit Contents The shed kit includes all the parts needed to assemble your shed except for tools and fasteners such as screws and nails. The various pieces are pre-cut and many are marked to indicate

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions This symbol on the product means the product is listed by Underwriters Laboratories, Inc. AMERI-VENT MODEL 10 FB FACTORY-BUILT CHIMNEY These are the three ways to

More information

G. Building the Cab, Cab Roof and Cab Boiler Extension Page 14 and Backhead.

G. Building the Cab, Cab Roof and Cab Boiler Extension Page 14 and Backhead. G. Building the Cab, Cab Roof and Cab Boiler Extension Page 14 and Backhead. Cab. In order to ensure that the cab and tender would actually look right, as what often appears on a drawing is not always

More information

TREX SIGNATURE (FORMERLY REVEAL) RAILING Installation Instructions

TREX SIGNATURE (FORMERLY REVEAL) RAILING Installation Instructions TREX SIGNATURE (FORMERLY REVEAL) RAILING Installation Instructions NOTES:» SIGNATURE POSTS CANNOT BE USED WITH SIGNATURE TRADITIONAL OR SIGNATURE COCKTAIL DESIGNS, ONLY PRESSURE TREATED POSTS/ POST SLEEVES

More information

Simplex Baseboard System Baseboard System

Simplex Baseboard System Baseboard System Simplex Baseboard System Baseboard System I Complete installation programme I Trouble-free and time-saving installation I Various connection kits for all types of pipe Our service to you I Simplex Products

More information

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)... INS-88.500-0A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Unpacking the KSCR... 2 2. Splicing the KSCR (If Required)... 4 3. Assemble Curb and Rail Corners... 5 4. Install Cross Bracing (If Required)...

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility C 1690" A 42926 75" 1905 150" 3810 G E F F 11 10 9 8 7 6 5 4 3 2 C D D 25 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 21.2 G E Impact 2270P 17 Spaces @ 75" [1905] Spacing = 106' 3" [32385] 1 1662 1/2"

More information

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

DURATECH CHIMNEY 5-8 DIAMETER INSTALLATION INSTRUCTIONS DURATECH 5"-8" DIAMETER INSTALLATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPOR- TANCE

More information

GV Standard Sliding Over Roof Installation Instruction Manual

GV Standard Sliding Over Roof Installation Instruction Manual GV Standard Sliding Over Roof Installation Instruction Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN 6ft Lean-To LEAN-TO Assembly Instructions 04/02 6ft Lean-To Greenhouse Base Plan Introduction/Tools/Contents / / Contents This is a copy of our Lean-To greenhouse base plan.

More information

W & A PARTS MANUAL STACKER BUSTER LEVEL BANDER. Model No Quality Products from W & A MANUFACTURING COMPANY

W & A PARTS MANUAL STACKER BUSTER LEVEL BANDER. Model No Quality Products from W & A MANUFACTURING COMPANY W & A PARTS MANUAL 12 ROW @ 38 STACKER BUSTER LEVEL BANDER Model No. 3668 SPECIALIZED FARM EQUIPMENT Quality Products from W & A MANUFACTURING COMPANY P.O. Box 5238, Pine Bluff, Arkansas 71611 Phone: (870)

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE

More information

MONASET CM-2. Has these customer proven features...

MONASET CM-2. Has these customer proven features... MONASET CM-2 Has these customer proven features... We looked at our successful Monaset grinder very closely before we came up with the engineering refinements which, when combined with its field proven

More information

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use db Omnidirectional Antenna and outdoor use 17 27 Omni 17 27 6 2dBi 8 41 N female Connector position Bottom or top 17 27 MHz SWR < 1.8 2 dbi Intermodulation IM < 15 dbc (2 x 4 dbm carrier) ertical 5 W (at

More information

Assembly Instructions. DucoGrille Classic 130HP 06/04/16

Assembly Instructions. DucoGrille Classic 130HP 06/04/16 Assembly Instructions DucoGrille Classic 130HP 06/04/16 DucoGrille Classic 130HP N fitting frame without flange Version: 06_04_2016 G fitting frame with flange Product presentation Mesh not shown 2 DucoGrille

More information

YWY M08 The new VELUX solution

YWY M08 The new VELUX solution YWY M08 The new VELUX solution VELUX roof windows and vertical window elements installed as a dormer in roof pitches between 42º and 52º YWY M08 is available as a double or triple unit and can be installed

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual [USA Fireplace Models [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE MODELS: STAND ALONE 7565 CURVED TUNNEL DOUBLE

More information

MODERN BED FRAME ROCKLER BUILD IT WITH BUILD SIMPLIFY CUSTOMIZE. Plan Value $14.99

MODERN BED FRAME ROCKLER BUILD IT WITH BUILD SIMPLIFY CUSTOMIZE. Plan Value $14.99 BUILD Stock # Item 63446 Baltic Birch Plywood /2" x 24" x 30" (2 qty) Stick veneer - Maple 24" x 96" 3/8" Dowels - Birch Bed Connector Hardware I-Semble Platform Bed Frame - Queen 3/8" Beadlock Basic Starter

More information

A - Railing Frame Material Specifications

A - Railing Frame Material Specifications A - Railing Frame Material Specifications NOTE: We strongly recommend stainless steel for exterior applications. R-1 8/1/02 B Stainless Steel Spacers (For Horizontal Railing Double Post End Post using

More information

FIXED FLAT ROOFLIGHT: INSTALLATION INSTRUCTIONS (Double & triple glazed)

FIXED FLAT ROOFLIGHT: INSTALLATION INSTRUCTIONS (Double & triple glazed) FIXED FLAT ROOFLIGHT: INSTALLATION INSTRUCTIONS (Double & triple glazed) Thank you for choosing to purchase a ROOF Maker Fixed Flat Rooflight. Assembly Procedure Guidance Please take precaution when moving

More information

UNIVERSAL BASES. #60UB - Universal Mounting Base. Same as above for 1/2 inside threads.

UNIVERSAL BASES. #60UB - Universal Mounting Base. Same as above for 1/2 inside threads. UNIVERSAL BASES #60U - Universal Mounting Base. This base can be used for vertical or horizontal mounting. Base is threaded for 3/8 inside threads. Made of bronze material for pastedown or fastening with

More information

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz ORDER NO. V3R MODEL V3R Collinear Gain Vertical for 216-225 MHz INSTRUCTION MANUAL General Description The new Hy-Gain V3R VHF antenna is a collinear 5/8-wave omnidirectional vertical antenna for the 216-225

More information

Veto spring agitator / kw burner heads

Veto spring agitator / kw burner heads 7.2004/2 Enclosure for Veto Chip Matic/ Veto Chip Matic Maxi instruction manual. Veto spring agitator / 160 640 kw burner heads Instruction manual Manufacturer ALA TALKKARI Veljekset Ala-Talkkari Oy Fin-62130

More information

9 ft Naramata Spa Shelter Assembly Manual Outdoor Living Today

9 ft Naramata Spa Shelter Assembly Manual Outdoor Living Today 9 ft Naramata Spa Shelter Assembly Manual Outdoor Living Today Version #8 Feb 20th, 2015 Thank you for purchasing a Naramata /Getaway Spa Shelter from Outdoor Living Today. Please take the time to identify

More information

Portofino Case2 Installation Guide

Portofino Case2 Installation Guide Portofino Case2 Installation Guide vjun16 (for 17 or 24 mm Surface Wall Profile) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Portofino Case 2 shower enclosure.

More information

FIRECHARM R.S. Electronic

FIRECHARM R.S. Electronic 987616 Issue 7 FIRECHARM R.S. Electronic Room Sealed Live Fuel Effect Gas Fire G.C. No. 32 689 43 (BLACK) G.C. No. 32 689 44 (BRONZE) Installation and Servicing Instructions CE MARKED FOR USE IN G.B. &

More information

NEW equinox INSTALLATION GUIDE Issue

NEW equinox INSTALLATION GUIDE Issue NEW equinox INSTALLATION GUIDE Issue 1 CONTENTS If in doubt at any stage 1. Preparing the ring beam 2 2. Installing the framework 3 3. Insulation and waterproofing 7 4. Tile application: Steel tiles 9

More information

SS13R SAFARI R-SPEC SNORKEL Nissan GQ Patrol with 4.2L TD42 Diesel Engine and Horizontal Pre-Cleaner.

SS13R SAFARI R-SPEC SNORKEL Nissan GQ Patrol with 4.2L TD42 Diesel Engine and Horizontal Pre-Cleaner. SS13R SAFARI R-SPEC SNORKEL Nissan GQ Patrol with 4.2L TD42 Diesel Engine and Horizontal Pre-Cleaner. Parts List 01/04/2015 ITEM PART NO DESCRIPTION QTY 1 470-133-200R BODY - SNORKEL 1 2 000-135-800 3

More information

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. E33 GAS INSERT ZERO CLEARANCE KIT Owner's & Installation KIT # 340-900 Manual PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance

More information

Roof Mount Ground Mount Specialised Clamps Spares Application Notes

Roof Mount Ground Mount Specialised Clamps Spares Application Notes DPA Solar Racking Solutions Solar PV Racking Catalogue Roof Mount Ground Mount Specialised Clamps Spares Application Notes www.dpasolar.com.au 1300 447 500 Rails & Splices Page 3 Mid & End Clamps Page

More information

Deauville Installation Guide

Deauville Installation Guide vjul16 (for 17 or 24 mm Surface Wall Profiles) DO NOT ASSEMBLE WITHOUT FULLY READING THESE INSTRUCTIONS Page 2 Thank you for purchasing this Deauville shower enclosure. Please study these instructions

More information

Warnings. Description. Prior to Installation Tools Needed

Warnings. Description. Prior to Installation Tools Needed Warnings Failure to act in accordance with the following may result in death or personal injury. The JT Strong Arm Stabilizer System is intended to eliminate chassis movement in travel trailers and fifth

More information

SIT Group FLUE SYSTEMS

SIT Group FLUE SYSTEMS SIT Group LN PRODUCT LINE FLUE SYSTEMS Index Twin Flue System 80 2 Twin Flue System 60 8 Coaxial System 10 Flue System Kit 13 TWIN FLUE SYSTEM 80 SERIES CHARACTERISTICS Extruded aluminium tubes (alloy

More information

Installation Guide. Tel: (519) Railway St. P.O Box 668 Seaforth, ON Canada N0K 1W0

Installation Guide. Tel: (519) Railway St. P.O Box 668 Seaforth, ON Canada N0K 1W0 Installation Guide Tel: (519) 527-2470 92 Railway St. P.O Box 668 Seaforth, ON Canada N0K 1W0 www.sunnorth.com Table of Contents...1 I. Table of Contents... 2 II. Installation Preparation... 2 Items Included...

More information

HBS-AP ASSEMBLING INSTRUCTIONS

HBS-AP ASSEMBLING INSTRUCTIONS ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,

More information

Universal Installation Instructions. Preparation and Safety Information. Natural Lighting by Monodraught. Dust. Scaffolding

Universal Installation Instructions. Preparation and Safety Information. Natural Lighting by Monodraught. Dust. Scaffolding Natural Lighting by Monodraught Universal Installation Instructions Preparation and Safety Information Scaffolding For flat roofs and single storey buildings not exceeding 10 ft. ( m) in height, access

More information

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL Masport Limited 1-37 Mt Wellington Highway Panmure Auckland 6 Ph: 09 571 1200 Fax: 09 571 5864 www.masport.com 2005 CONTENTS Ordering Information... Page 3 Freestanding

More information

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia

More information

Ultraroof380 Cornice Installation

Ultraroof380 Cornice Installation Ultraroof380 Cornice Installation The complete guide to installing Cornice onto an Ultraroof380 (2 high decorative Cornice) PLEASE READ BEFORE FITTING CORNICE PRE INSTALLATION INFORMATION Recommended tools

More information

STOL CH 701. Clamp a reference extrusion on the bottom of the spar. Clamp the bottom flange of the rib to the extrusion. Rear Root Rib 7V4-2

STOL CH 701. Clamp a reference extrusion on the bottom of the spar. Clamp the bottom flange of the rib to the extrusion. Rear Root Rib 7V4-2 Rear Root Rib 7V4-2 Clamp a reference extrusion on the bottom of the spar. Clamp the bottom flange of the rib to the extrusion. Cleco the root nose rib to the spar Position the rear root rib at station

More information

Variable Pitch Collector Frame

Variable Pitch Collector Frame Variable Pitch Collector Frame INSTALLATION INSTRUCTIONS FOR SOLAR WATER HEATER SYSTEMS This frame must be installed by an authorised person. Please leave this guide with a responsible officer or the householder.

More information

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW) WALL TO WALL (W) CORNER WALL (CW) FLOOR

More information

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device 911375-00 Surface Vertical Rod Exit Device 98/9927 Installation Instructions Devices covered by these instructions: 98/9927 Surface Vertical Rod Exit Device 98/9927-F (Fire) Surface Vertical Rod Exit Device

More information

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F350 08-09 1 guard, center section 1 brush guard, left side 1 brush guard, right side 1 wire guard

More information

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB / GB 99-11-03/01 1-38 Index 1 CONFORMITY OF APPLIANCE 3 2 MAIN ASSEMBLY TYPES 3 2.1 Under worktop 3 2.2 Double door 10 2.3 Combined 14 2.4 Single door Fridge or single door Freezer 19 2.5 Combined free-standing

More information

GROWING BETTER THROUGH DESIGN. Regent Royale Rosette Regal GREENHOUSE. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN. Regent Royale Rosette Regal GREENHOUSE. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN Regent Royale Rosette Regal GREENHOUSE Assembly Instructions 04/02 Greenhouse Base Plan We cannot emphasis how important it is to have a proper base for your Robinsons Greenhouse

More information

ALL SEASON PATIO COVER

ALL SEASON PATIO COVER ALL SEASON PATIO COVER 61 Where the All Season Patio Cover is to be attached to the home, create a level line showing where the top of the mounting rail is to be located. Install each section with the

More information