Advanced instrumentation solutions crafted with highest precision
|
|
- Noel Eaton
- 5 years ago
- Views:
Transcription
1 Advanced instrumentation solutions crafted with highest precision
2 perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the electrodes is further processed by the transmitter to give standardised output signal or displayed in appropriate engineering unit. The flux density of the electromagnetic field in a given Flowmeter and the distance between the electrodes are constant. Therefore, the induced voltage is only a function of liquid velocity. E = KxBxvxD where E : Induced voltage K : Flow tube constant B : Magnetic field strength v : Mean flow velocity and D : Electrode spacing Volume flow is calculated by equation 2 Q = vxd xb/4 MagFlow 641 Working Principle Electromagnetic Flowmeters are based on Faraday's Law of Electromagnetic Induction. In an Electromagnetic Flowmeter, the magnetic field is generated by a set of coils. As the conductive liquid passes through the electromagnetic field, an electric voltage is induced in the liquid, which is directly proportional to its velocity. This induced voltage is ExDxB Therefore, Q = KxBx4 The induced voltage is not affected by the physical properties of liquid like temperature, viscosity, pressure, density and conductivity, as long as conductivity of the measured liquid is above minimum threshold level. For reliable measurement, the pipe must be completely full of liquid. The electromagnetic field coil assembly is excited by pulsed DC technique, which eliminates the interfering noise and provides automatic zero correction. MagProbe 645 EcoMag 642 MagBP 644 2
3 Technical Specifications : Series 64 Parameters Nominal dia (mm) 2 Working pressure (kg/cm ) MagFlow to 2 1, 16, 25, 4 EcoMag to 15 5 MagBP to 1 1, 16, 25, 4 MagProbe 645 > 1 2 Working temperature Integral PTFE - 12 Remote PTFE - 18 C Others - 7 C C Up to 55 C Up to 55 C Up to 12 C Electrode material Sensor lining Display version Measuring tube material Sensor housing material End connection Flange - Standard Measuring range Accuracy % of measured value Repeatability Display Std. Rubber* SS34 Std.* Std. CS* Flange/Wafer/Tri-clamp ANSI 15*.2 to 12 m/sec. Bidirectional ±O.5 (±O.2% consult factory) ±.2% of span 2 line LCD/LED HDPE HDPE Flange ANSI 15*.2 to 12 m/sec. Bidirectional ±1% ±.2% of span 2 line LCD/LED Std. Rubber* SS34 Std.* Std. CS* Flange/Wafer/Tri-clamp ANSI 15*.2 to 12 m/sec. Bidirectional ±1% ±.2% of span 2 line LCD SS316 Std.*.2 to 12 m/sec. Bidirectional ±2% ±.2% of span 2 line LCD/LED Display units Output Std. 4-2 ma* Std. 4-2 ma* Std. 4-2 ma* Power supply 24 V DC or 8-3 V AC 24 V DC or 8-3 V AC Battery powered 5 years battery life 24 V DC or 8-3 V AC Protection class for sensor Std. IP 65 Option IP 68 for flow tube in remote type Std. IP 65 Option IP 68 for flow tube in remote type Std. IP 65 Option IP 68 for flow tube in remote type Std. IP 68 Protection class for transmitter Cable length for remote Std. 1 m Std. 1 m Std. 1 m Std. 1 m Installation Inline flanged type Inline flanged type Inline flanged type Insertion type with use of isolating ball valve assembly on pipeline. * Please refer to order code for options. Electromagnetic Flowmeter Series 64 3
4 Electromagnetic Flowmeter Components Cable gland Display Transmitter Earthing ring Coil housing Liner (Rubber/PTFE) Flange Minimum - Maximum Flow Table Velocity range -.2 m/sec. for minimum & 12 m/sec. for maximum DN in mm m /hr. LPM LPS USGPM Min. Max. Min. Max. Min. Max. Min. Max Installation precautions 1. Installation location should be such that the Flowmeter will always remain full with liquid. 2. A minimum 5D upstream & 3D downstream straight lengths should be maintained at installation locations where D is the pipe diameter. 3. The Flowmeter installation location should be free of bends, elbows, tees, valves, etc. 4
5 Ordering Code : Series 64 Approval M1 - MagFlow 641 Sensor Size D - None M2 - EcoMag (¼ ) F - Flameproof M3 - MagBP 644 M4 - MagProbe (½ ) 2-2 (¾ ) G - Any other (Pl. specify) (1 ) Transmitter Type I - Integral R - Remote (1.25 ) 4-4 (1.5 ) 5-5 (2 ) Protection Class for Sensor A - IP 65 View Software Y - Required (select communication interface) N - Not required Power Supply P1-24 V DC P2-8 to 3 AC P3 - Solar powered P4 - Battery powered (642, 644, 645) P5 - Any other (Pl. specify) Output OP ma DC OP ma DC OP3 - Pulse output OP4 - Relay output OP5 - Combinations of above OP6 - Any other (Pl. specify) (2.5 ) 8-8 (3 ) 1-1 (4 ) (5 ) (6 ) 2-2 (8 ) (1 ) 3-3 (12 ) (14 ) 4-4 (16 ) (18 ) 5-5 (2 ) 6-6 (24 ) 7-7 (28 ) 8-8 (32 ) 9-9 (36 ) 1-1 (4 ) (48 ) (56 ) T1 - SS 34 T2 - SS 316 B - C - IP 68 Coil Housing CH1 - CS / MS CH2 - SS 34 CH3 - SS 316 Measuring Tube CH4 - Any other (Pl. specify) T3 - Any other (Pl. specify) Earthing Rings 1 - None (Earth electrode) 2 - SS SS 316L Communication Interface (64 ) 4 - Any other (Pl. specify) C1 - Not applicable (72 ) C2 - RS 232 (Modbus RTU) C3 - RS 485 (Modbus RTU) C4 - HART C5 - GSM C6 - GPRS 2-2 (8 ) Any other (Pl. specify) Electrode Material E1 - SS 316 E2 - SS 316L E3 - Hastelloy C E4 - Titanium Data Logger E5 - Tantalum Y - External (Pl. specify) E6 - Platinum N - Not required E7 - Any other (Pl. specify) Pressure Rating Design of Measuring Sensor Flange Material Sensor Lining R1-5 kg/cm² ( 642) S1 - Flange ANSI 15 F1 - CS / MS L1 - Hard rubber R2-1 kg/cm² S2 - Flange DIN PN F2 - SS 34 L2 - Neoprene R3-16 kg/cm² S3 - Flange BS 1 Table D/E F3 - SS 316 L3 - PTFE R4-25 kg/cm² S4 - Wafer F4 - Any other (Pl. specify) L4 - Polyurethane R5-4 kg/cm² S5 - SMS L5 - PFA R6 - Any other (Pl. specify) S6 - Tri clamp L6 - HDPE S7 - Any other (Pl. specify) L7 - Any other (Pl. specify) Note : For MagProbe 645 Insertion Type Flowmeter - sensor size, design of measuring sensor, flange material, sensor lining, earthing, coil housing choices are not available. 5
6 Sales and Service Network Delhi Jaipur Ahmedabad Bhopal Kolkata Mumbai «Pune «Corporate Office & Plant Regional Office Dealer Hyderabad Bangalore Chennai Adept Fluidyne Pvt. Ltd. Corporate Office & Plant : Plot 4, S No. 17/1-B, Kothrud Ind. Estate, Kothrud, Pune INDIA T / E info@adeptfluidyne.com L Adept Series 64 / 115 / SK / kaleidoscopeb2b.com Technical changes reserved
Advanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Rely on us for competency, capacity and customer care Operating in instrumentation business since 1983 Well-known
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationS103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING
ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More informationCONDUCTIVITY TYPE LEVEL SWITCHES
CONDUCTIVITY TYPE LEVEL SWITCHES 2460 1. CONDUCTIVITY TYPE LEVEL SWITCH - CLS It is a simple, low cost, point level controller designed for detection of conductive liquids, having low densities, high viscosities,
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits SITRANS F flowmeters System information FLO Easier to commission All FLO feature a unique SENSORPROM memory
More informationSITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9
Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement
ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp
More informationMagnetic Inductive Flowmeter
Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationULTRASONIC FLOW METER FT101
Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationABB Instrumentation. Flowmeter. Specification DataFile
MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.
More informationElectromagnetic Flow Measuring System promag 35
Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationIFS Electromagnetic flow sensor
Technical Datasheet Electromagnetic flow sensor Flow sensor for the process industry Special flow sensor for harsh media and slurries For demanding applications: High temperatures, high pressures, low
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationAbridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter
Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationU LT RAFLO WARANTY CERTIFICATE. R a t e I n d i c a t o r OPERATION MANUAL. FieldMounted A-110. Panel Mounted J-110. Test Report. Actual.
Test Report Standard Actual Product www.vatsmeter.com Model Sr. No. Line Size: This is to certify that the products mentioned above have been tested and calibrated at our works and have been found working
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationELECTROMAGNETIC FLOWMETER
ELECTROMAGNETIC FLOWMETER ELECTROMAGNETIC FLOWMETER 1 EFS800 - CFT180/RFT200 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring principle of the
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter
ABB MEASUREMENT & ANALYTICS DATA SHEET HygienicMaster FEH630 Electromagnetic flowmeter 2 HYGIENICMASTER FEH630 ELECTROMAGNETIC FLOWMETER DS/FEH630-EN REV. C Measurement made easy The clean choice for all
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P
Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationMagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter
OVERVIEW MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter The MagneW Two-wire PLUS+is a high performance electromagnetic flowmeter based on field proven Azbil Corporation s two-wire loop powered
More informationE l e c t r o m a g n e t i c f l o w m e t e r s
E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without
More informationU LT RAFLO OPERATION MANUAL WARANTY CERTIFICATE. R a t e I n d i c a t o r. FieldMounted A-110. Panel Mounted J-110. Test Report.
Test Report Standard Actual Product www.vatsmeter.com Model Sr. No. Line Size: This is to certify that the products mentioned above have been tested and calibrated at our works and have been found working
More informationMagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401 P R O V E N A N D R E L I A B L E F L O W M E A S U R E M E N T 2 MJK MagFlux flow meters combine high accuracy, stability and
More informationIFC 021 K, F Signal Converter. For electromagnetic flowmeters. Easy and user-friendly installation and operator control
IFC 01 K, F Signal Converter For electromagnetic flowmeters Easy and user-friendly installation and operator control Self monitoring features to rule out errors in operation Field proven design. More than
More informationTechnical Information Proline Promag 10P
TI00094D/06/EN/13.17 71385977 Products Solutions Services Technical Information Electromagnetic flowmeter Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H
Technical Information TI 051D/06/en 50097004 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H Flow measurement in hygiene, food and beverage or process applications Features
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationFlow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.
Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical
More informationwprime TM Series 280W-CI ULTRASONIC WATER METER
MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water
More informationELECTROMAGNETIC FLOW METER AFLOWT MF
ELECTROMAGNETIC FLOW METER AFLOWT MF OPERATION MANUAL 9001:2008 Saint-Petersburg, Russia * * * VZLJOT JSC quality management system is certified to ISO 9001:2008 * * * Vzljot JSC Postal address: Masterskaya
More information8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes
Product Specifications 8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined to 150 mm (1/16 to 6 in) Line Sizes PSS 1-6F2 A 8000A SERIES MAGNETIC FLOWTUBE These compact, ceramic- or
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationProline Promag 55S. Technical Information
Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationOptimize your Ultrasonic Flow Meter for Water & Wastewater Applications
Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Brent Baird, Instruments Direct 2013 ISA
More informationT EK-FLUX 1400A Electromagnetic Flowmeter
T EK-FLUX 1400A Electromagnetic Flowmeter Instruction Manual Document Number: IM-1400A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,
More informationMagnetic level indicators made in Australia under licence to Weka AG of Switzerland.
ABN 24 080 175 293 PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0)2 9542 8977 fx: +61 (0)2 9542 7978 www.controlcomponents.com.au Magnetic level indicators made in Australia under licence to
More informationMaxxFlow HTC Flow Measurement for Dry Bulk Solids
EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationRate Indicator + Totalizer + Controller
Test Report Standard Actual www.vatsmeter.com Product Model Sr. No. Line Size: This is to certify that the products mentioned above have been tested and calibrated at our works and have been found working
More informationSpecifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K
Field Intelligent Device Series-Mount Anywhere series-flanged ELECTROMAGNETIC FLOWMETER LF664/LF620 LF664/LF622 20 to 78 (500 to 1950mm) Introduction The electromagnetic flowmeter uses Faraday s Law of
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationElectromagnetic Flow Measuring System promag 33
Technical Information TI 07D/06/en No. 50063743 Electromagnetic Flow Measuring System promag 33 Flexible System Wide choice of materials for process connections and measuring tube linings, compatible to
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationElectromagnetic Flowmeter. Instruction Manual
TEK-FLUX 1400A Electromagnetic Flowmeter Instruction Manual Document Number: IM-1400A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,
More informationMIK COMPACT MAGNETO-INDUCTIVE FLOWMETER
MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,
More informationMagnetic-Inductive flow Meter fmi
1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and
More informationVortexMaster FSV430, FSV450 Vortex flowmeter
Data Sheet DS/FSV430/450-EN Rev. F VortexMaster FSV430, FSV450 Vortex flowmeter Reliable measurement of liquids, gases and steam in volume, mass or energy units Measurement made easy ABB common look and
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationLevel gauges Series LT Level indicator, switch and transmitter for liquids
Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationMS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM
CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MAGFLO MMFM MAGNETIC FLOW METER (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 Introduction Please read carefully! No liability can be
More informationHTTF Transit Time Ultrasonic Flow Meter
Transit Time Ultrasonic Flow Meter Reduced material costs: clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers, and filters Reduced installation time: the may be installed
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationSmart Two-wire Electromagnetic Flowmeter
MagneW Two-wire PLUS + Smart Two-wire Electromagnetic Flowmeter Model MTG18A (Integral type) Model MTG14/MTG18B (Remote type) OVERVIEW The MagneW Two-wire PLUS + is a high performance electromagnetic flowmeter
More informationCAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS
LEVEL MEASUREMENT & CONTROL SOLUTIONS CAPACITANCE TYPE LEVEL SWITCH FOR LIQUIDS 114 MLS Capacitance Type Level Switch 114 MLS uses SBEM s proven capacitance technology with added feature of Microprocessor.
More informationTechnical Information Proline Promag 55S
TI00071D/06/EN/14.17 71385973 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics Application
More informationOPTIFLUX 2000 Technical Datasheet
OPTIFLUX 2000 Technical Datasheet Electromagnetic flow sensor For all water and wastewater applications Wide range of approvals for potable water Robust, fully welded construction The documentation is
More information