Automation Components, Inc. CURRENT 4-20 MA OUTPUT
|
|
- Dinah Farmer
- 5 years ago
- Views:
Transcription
1 D A T A S H E E T S
2 Automation Components, Inc. CURRENT 4-20 MA OUTPUT 4-20 MA OUTPUT CTA2, SCTA2, CTA2-RMS & SCTA2-RMS Series The 4-20 ma Output Analog Current Sensors are designed for use in any AC current monitoring application in which you are looking to monitor a particular piece of equipment. The style current sensors should be used in applications where the Sinusoidal waveform has no distortion or noise on the conductor being monitored. Applications may include monitoring a resistive type load such as an incandescent light bulb, heating element as well as any single speed linear load. Note that the True RMS sensors are able to be used in all applications since the True RMS current sensors provide the best overall accuracy and should be used in applications which includes Variable Frequency Drives, Switching Power Supplies, Computers and Data Centers, Electronic Ballasts, SCR s, and Variable Speed Loads. For currents monitored above 250 Amps, the CTA2-5 and SCTA2-5 are ideal for use with a step down Ratio:5A Output CT (Current Transformer) in stepping down current in a monitored conductor to a proportional 0 to 5A output signal. The current sensors are available in both solid and split-core versions which also includes a Patented (Pat. No. US 7,416,421) 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues like dust and moisture may be of concern. The split-core version of the current sensors work great in retrofit applications and for use on service technicians vehicles since one or two parts will work in most applications and can be easily installed without disconnecting any wires. Applications: Load Trending, Basic Power Monitoring, Electronic Ballasts, Computers/Data Centers, Industrial, Variable Speed Loads, Pumps, Compressors, Fans, Preventative Maintenance, LEED, Project Justification (ROI) Process Control, Solid State Environments (SCR s) The 4-20 ma Output Current Sensors are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: AC Current Maximum AC Voltage: 600 VAC Isolation Voltage: 2200 VAC Operating Frequency Range 2: A/CTA2 & A/SCTA2 Series: 40 to 1KHz A/CTA2-50-RMS & A/SCTA2-50 RMS: 15 to 100 Hz A/CTA2-250-RMS (0-100A Range): 15 to 100 Hz A/CTA2-250-RMS (0-200/250A Ranges): 30 to 100 Hz Core Style: and Versions available (See Ordering Grid) Supply Voltage: +8.5 to 30 VDC (Reverse Polarity Protected) 250 Ohm Load (1-5 VDC): to 30 VDC 500 Ohm Load (2-10 VDC): to 30 VDC Maximum Load 24 VDC: 775 Ohms (Formula: (24 VDC 8.5 VDC) / 0.020A ) Supply Current: 25 ma minimum Sensor Amperage Range: See Ordering Grid (Field Selectable) Output Signal Maximum Output Signal: (2-Wire, Loop Powered) Limited to 25 ma Accuracy 1: All Models: +/- 1% of Selected Range except A/SCTA2-50-RMS: +/- 2% from 15 to 20 Hz +/- 1% from 20 to 100 Hz Response Time: A/CTA2-xxx and A/SCTA2-XXX: < 600 ms (Rise and Fall Time) A/CTA2-xxx-RMS & A/SCTA2-50-RMS: 600 ms (Rise Time) and 2800 ms (Fall Time) Aperture Size: 0.75 (19.05 mm) Din Rail Size: 35 mm (U.S. Patent No. 7,416,421) Operating Temperature Range: 5 to 104ºF (-15 to 40ºC) Operating Humidity Range: 0 to 95%, non-condensing Storage Temperature RH Range: 41 to 95 F (5 to 35 C) 40% to 85% RH, non-condensing Enclosure Material Flammability Rating: PC/ABS (Polycarbonate/ABS Blend) UL94-V0 Wiring Connections: 2 Position, Screw Terminal Block (Polarity Sensitive) Wire Recommendations: 2 Conductor (Shielded Cable) Wire Size: 18 to 24 AWG (0.823 mm2 to mm2) Copper Wires only Terminal Block Torque Rating: 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) Minimum Mounting Distance: 1 (2.6 cm) between current sensor & other magnetic devices (Relays, Contactors, Transformers) Agency Approvals: CE (-RMS Versions): CE to IEC : 2012 Class A, UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E309723), RoHS2, WEEE Product Weight: A/CTA2-xxx: lbs. (0.118 kg) A/SCTA2-xxx: lbs. (0.124 kg) A/CTA2-xxx-RMS: lbs. (0.087 kg) A/SCTA2-xxx-RMS: lbs. (0.087 kg) Product Dimensions: Solid Core Versions: (70.11 mm) x (84.92 mm) x (26.67 mm) Split Core Versions: (70.51 mm) x (82.25 mm) x (28.45 mm) Note1: All current output sensors are calibrated at an ambient room temperature of 71ºF (21.5ºC) Note2: Only the 0 to 100 Amp range in the A/CTA2-250-RMS will meet accuracy specifications from 15 to 100 Hz Call: Web: CURRENT ##
3 CURRENT 4-20 MA OUTPUT Automation Components, Inc. DIMENSIONAL DRAWING 2.36 (59.94mm) 2.87 (72.80mm) (70.45mm) 1.03 (26.16mm) 3.35 (84.99mm) 2.55 (64.69mm) 2.87 (72.77mm) (70.35mm) 1.10 (28.02mm) 3.24 (82.23mm) Front View Right View Bottom View STANDARD ORDERING A/CTA2-5 A/CTA2-50 A/CTA2-250 A/SCTA2-5 A/SCTA2-50 A/SCTA2-200 A/CTA2-50-RMS A/CTA2-250-RMS A/SCTA2-50-RMS Item # Selectable Ranges 0 to 5A 0 to 100/200/250A 0 to 5A 0 to 100/150/200A 0 to 100*/200/250A Measurement True RMS True RMS True RMS AC Waveform Distorted & Distorted & Distorted & Note*: Only the 100 Amp Range will meet the accuracies over the operating frequency range of 15 to 100 Hz (See Specification Table) Example: A/CTA2-5 -OR Output Signal ACCESSORIES ORDERING Item # Description Ohm, 1/4W, +/- 1% Tolerance, 50 PPM Resistor Ohm, 1/4W, +/- 0.1% Tolerance, 50 PPM Resistor (Recommended for Best Accuracy) Ohm, 1W, +/- 1% Tolerance, 50 PPM Resistor Item # Example: The 4-20 ma Output Current Sensors are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
4 Automation Components, Inc. CURRENT ADJUSTABLE SWITCHES ADJUSTABLE SWITCHES ACS2, ACSX2, ASCS2 & ASCSX2 Series The Adjustable Current Switches are designed for use in any AC current monitoring application in which you are looking to monitor a particular piece of equipment for equipment failure, preventative maintenance, status, and electrical load status. The current switches should be installed on the line side of the power to the electrical equipment. The current switches are available in both solid and split-core versions which also includes a Patented 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern. The split-core version of the current switches work great in retrofit applications and for use on service technicians vehicles since one part will work in most applications and can be easily installed without disconnecting any wires. The adjustable current switches can be used to determine the run time of your equipment as well as basic load trending applications where you want to know when how long your piece of equipment runs when logging the contact closures on your building management system or PLC. Applications: Overload Conditions, Underload Conditions, Normal Operating Conditions, Broken Belts, Belt Slippage, Locked Rotors, Equipment Failure, Fans, Pumps, Compressors, Motors, Ovens, Industrial Equipment, Lighting Status and Usage, Electrical Load Status, Local Alarms (Strobes and Audible Alarms), Preventative Maintenance Scheduling The Adjustable Current Switches are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: AC Current Maximum AC Voltage: 600 VAC Operating Frequency Range: 40 to 1 khz Core Style: and Versions available (See Ordering Grid) Sensor Power: Induced from the Monitored Conductor Amperage Range: See Ordering Grid Isolation Voltage: 2200 VAC Trip Point Style Trip Point: Adjustable Trip Point See Ordering Grid Hysteresis: 10% of trip point, typical Contact Type: Normally-Open N/O or Normally-Closed N/C (See ordering Grid) Status Contact Rating: Status Contact On Resistance Off Resistance: < 10 Ohms (tripped) > 1 Meg Ohms (Open) Response Time: See Response Time Table on back of data sheet Status LED Indication 1: Red LED (Current above Trip Point) Blue LED (Current Below Trip Point) Aperture Size: 0.75 (19.05 mm) Din Rail Size: 35 mm (U.S. Patent No. 7,416,421) Operating Temperature Range: 5 to 104ºF (-15 to 40ºC) Operating Humidity Range: 0 to 95%, non-condensing Recommended Storage Temperature RH Range: 41 to 95 F (5 to 35 C) 40% to 85% RH, non-condensing Enclosure Material Flammability Rating: PC/ABS (Polycarbonate/ABS Blend) UL94-V0 Wiring Connections: 2 Position, Screw Terminal Block (Not Polarity Sensitive) Wire Size: 16 to 22 AWG (1.31 mm2 to 0.33 mm2) Copper Wires only Terminal Block Torque Rating: 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) Minimum Mounting Distance: 1 (2.6 cm minimum) between current switch (Relays, Contactors, Transformers) Agency Approvals: UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E309723), CE, RoHS2, WEEE Product Weight: A/ACS2 and A/ACSX2: lbs. (0.097 kg) A/ASCS2: lbs. (0.123 kg) A/ASCSX2: lbs. (0.121 kg) A/ASCS2-L: lbs. (0.127 kg) Product Dimensions (L x W x H): Solid Core Versions: (70.11 mm) x (84.92 mm) x (26.67 mm) Split Core Versions: (70.51 mm) x (82.25 mm) x (28.45 mm) Note1: The LED should not be used to determine if current is present. At low currents the LED may not be visible Call: Web: CURRENT ##
5 CURRENT ADJUSTABLE SWITCHES Automation Components, Inc. DIMENSIONAL DRAWING 2.36 (59.94mm) 2.87 (72.80mm) (70.45mm) 1.03 (26.16mm) 3.35 (84.99mm) 2.55 (64.69mm) 2.87 (72.77mm) (70.35mm) 1.10 (28.02mm) 3.24 (82.23mm) Front View Right View Bottom View RESPONSE TIME A/ACS2 A/ACSX2 A/ASCS2 A/ASCSX-2 A/ASCS2-L 0.50 Amps 221mS 260mS 0.60 Amps 400mS 0.75 Amps 144mS 169mS 270mS 1.0 Amp 109mS 130mS 183mS 1.50 Amps 248mS 344mS 10 Amps 63mS 82mS 68mS 92mS 62mS 20 Amps 59mS 74mS 65mS 86mS 60mS Note*: unit was not tested (below minimum trip point or for that range) STANDARD ORDERING Example: A/ACS2 -OR A/ACS2 A/ACSX2 A/ASCS2 A/ASCS2-L A/ASCSX2 Item # Trip Point Type Adjustable Adjustable Adjustable Adjustable Adjustable N/O N/C Amp Range 0 to 250A 0 to 250A 0 to 250A 0 to 250A 0 to 250A Trip Point 0.5 to 220A 0.5 to 220A 1.5 to 220A 0.6 to 180A 1.5 to 220A Contact Rating The Adjustable Current Switches are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
6 Automation Components, Inc. CURRENT FIXED STATUS SWITCHES FIXED STATUS SWITCHES CS2, CSX2, SCS2 & SCSX2 Series The ACI Fixed Status Current switches are designed for use in any AC current monitoring application in which you are looking for a Go/No Go or On/Off status for a particular piece of equipment. The current switches should be installed on the line side of the power to the motor, pump, compressor or other equipment. The current switches are available in both solid and split-core versions which also includes a Patented 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern. The split-core version of the current switches work great in retrofit applications and for use in service vehicles since one part will work in most applications and can be installed without disconnecting any wires. The fixed current status switches can also be used to determine the run time of your equipment and basic load trending applications where you want to know when your piece of equipment runs and for how long it runs for when logging the contact closures on your building management system or PLC. Applications: Pump Status, Fan Status, Compressors, Motor Status, Ovens, Industrial Equipment, Lighting Status and Usage, Electrical Load Status, Local Alarms (Strobes and Audible Alarms) The Fixed Current Switches are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: Maximum AC Voltage: Operating Frequency Range: Core Style: Sensor Power: Amperage Range: Isolation Voltage: Trip Point Style Trip Point: Contact Type: Status Contact Rating: Status Contact On Resistance Off Resistance: Response Time: Status LED Indication 1: Aperture Size: Din Rail Size: Operating Temperature Range: Operating Humidity Range: Recommended Storage Temperature RH Range: Enclosure Material Flammability Rating: Wiring Connections: Wire Size: Terminal Block Torque Rating: Minimum Mounting Distance: Agency Approvals: Product Weight: Product Dimensions (L x W x H): AC Current 600 VAC 40 to 1 khz and Versions available (See Ordering Grid) Induced from the Monitored Conductor See Ordering Grid 2200 VAC Fixed Trip Point See Ordering Grid Normally-Open N/O or Normally-Closed N/C (See ordering Grid) < 10 Ohms (tripped) > 1 Meg Ohms (Open) See Response Time Table on back of data sheet Red LED (Monitored current is above Trip Point) 0.75 (19.05 mm) 35 mm (U.S. Patent No. 7,416,421) 5 to 104ºF (-15 to 40ºC) 0 to 95%, non-condensing 41 to 95 F (5 to 35 C) 40% to 85% RH, non-condensing PC/ABS (Polycarbonate/ABS Blend) UL94-V0 2 Position Screw Terminal Block (Not Polarity Sensitive) 16 to 22 AWG (1.31 mm2 to 0.33 mm2) Copper Wires only 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) 1 (2.6 cm) between current switch (Relays, Contactors, Transformers) UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E309723), CE, RoHS2, WEEE A/CS2 and A/CSX2: lbs. (0.099kg) A/SCS2 and A/SCSX2: lbs. (0.123 kg) A/SCS2-L: lbs. (0.127 kg) Solid Core Versions: (70.11 mm) x (84.92 mm) x (26.67 mm) Split Core Versions: (70.51 mm) x (82.25 mm) x (28.45 mm) Note1: The LED should not be used to determine if current is present. At low currents the LED may not be visible Call: Web: CURRENT ##
7 CURRENT FIXED STATUS SWITCHES Automation Components, Inc. DIMENSIONAL DRAWING 2.36 (59.94mm) 2.87 (72.80mm) (70.45mm) 1.03 (26.16mm) 3.35 (84.99mm) 2.55 (64.69mm) 2.87 (72.77mm) (70.35mm) 1.10 (28.02mm) 3.24 (82.23mm) Front View Right View Bottom View RESPONSE TIME A/CS2 A/CSX2 A/SCS2 A/SCSX-2 A/SCS2-L 0.15 Amps 156mS Green Boxes: response time at specified current above trip point Red Boxes: response time below specified trip point where sensors may trip 0.20 Amps 100mS 189mS 224mS 0.25 Amps 84mS 134mS 144mS 0.50 Amps 484mS 65mS Note: = unit was not tested (below minimum trip point or for that range) 0.75 Amps 47mS 1.0 Amp 32mS 48mS 72mS 39mS 1.20 Amps 194mS 1.50 Amps 45mS 102mS 10 Amps 26mS 42mS 26mS 42mS 25mS 20 Amps 24mS 41mS 20mS 42mS 22mS STANDARD ORDERING Example: A/SCSX2 -OR A/CS2 A/CSX2 A/SCS2 A/SCS2-L A/SCSX2 Item # Trip Point Type Fixed Trip Point Fixed Trip Point Fixed Trip Point Fixed Trip Point Fixed Trip Point N/O N/C Amp Range 0 to 250A 0 to 250A 0 to 200A 0 to 200A 0 to 200A Trip Point 0.25A or less 0.25A or less 1.5A or less 0.5A or less 1.5A or less Contact Rating The Fixed Current Switches are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
8 Automation Components, Inc. CURRENT VOLTAGE OUTPUT VOLTAGE OUTPUT CTE2, SCTE2, CTV2 & SCTV2 Series The Voltage Output Analog Current Sensors are designed for use in any AC current monitoring application in which you are looking to monitor a particular piece of equipment for proper operation. All voltage output current sensors use an current measuring method and should be used in applications where a pure Sinusoidal AC waveform that has very little or no distortion/noise on the conductor being monitored. Applications may include monitoring a resistive type load such as an incandescent light bulb or heating element as well as any single speed linear load. Voltage Output current sensors are available in both solid and split-core versions which also includes a Patented 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues like dust and moisture may be of concern. The split-core version of the current sensors work great in retrofit applications and for use on service technicians vehicles since one or two parts will work in most applications and can be easily installed without disconnecting any wires. For best results, the voltage output current sensors should not be used in applications with switching power supplies or variable speed drives due to the limited operating frequency range. In applications where variable speed drives or waveforms include distortion/noise, ACI recommends the use of the A/CTA2-RMS or A/SCTA2-RMS Series sensors where you need to supply 24 VDC power to the current sensors with a 4-20 ma signal. A 249 Ohm or 499 Ohm 1 Watt resistor can be used to convert the 4-20 ma signal into a useable 1-5 or 2-10 VDC output signal at your building management system or PLC. Applications: Load Trending, Single Speed Loads, Pumps, Compressors, Fans, Preventative Maintenance, LEED, Project Justification (Calculating ROI), Process Control The Voltage Output Current Sensors are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: AC Current Maximum AC Voltage: 600 VAC Isolation Voltage: 2200 VAC Operating Frequency Range: 50 to 600 Hz Core Style: and Versions available (See Ordering Grid) Supply Voltage: Induced from the Monitored Conductor (Insulated Conductors only) Sensor Amperage Range: See Ordering Grid (Field Selectable) Output Signal Number of Wires: A/CTE2 & A/SCTE2 Series: 0 to 5 VDC A/CTV2 & A/SCTV2 Series: 0 to 10 VDC 2-Wires Accuracy 1: A/CTE2 & A/SCTE2 Series (0-10A Range Only): +/- 1% from 5-100% of Selected Range A/CTE2 & A/SCTE2 Series (All Other Ranges): +/- 1% from 2-100% of Selected Range A/CTV2 & A/SCTV2 Series: +/- 1% from 5-100% of Selected Range Response Time: < 300 ms (Rise and Fall Times) Aperture Size: 0.75 (19.05 mm) Din Rail Size: 35 mm (U.S. Patent No. 7,416,421) Operating Temperature Range: 5 to 104ºF (-15 to 40ºC) Operating Humidity Range: 0 to 95%, non-condensing Recommended Storage Temperature RH Range: 41 to 95ºF (5 to 35ºC) 40% to 85% RH, non-condensing Enclosure Material Flammability Rating: PC/ABS (Polycarbonate/ABS Blend) UL94-V0 Wiring Connections: 2 Position, Screw Terminal Block (Polarity Sensitive) Wire Recommendations: 2 Conductor (Shielded Cable) Wire Size: 18 to 24 AWG (0.823 mm2 to mm2) Copper Wires only Terminal Block Torque Rating: 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) Minimum Mounting Distance: 1 (2.6 cm) between current sensor & other magnetic devices (Relays, Contactors, Transformers) Agency Approvals: UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E309723), CE, RoHS2, WEEE Product Weight: A/CTE2-xxx & A/CTV2-xxx Series: lbs. (0.088 kg) A/SCTE2-xxx & A/SCTV2-xxx Series: lbs. (0.125 kg) Product Dimensions (L x W x H): Solid Core Versions: (70.11 mm) x (84.92 mm) x (26.67 mm) Split Core Versions: (70.51 mm) x (82.25 mm) x (28.45 mm) Note1: All current output sensors are calibrated at an ambient room temperature of 71ºF (21.5ºC) Call: Web: CURRENT ##
9 CURRENT VOLTAGE OUTPUT Automation Components, Inc. DIMENSIONAL DRAWING 2.36 (59.94mm) 2.87 (72.80mm) (70.45mm) 1.03 (26.16mm) 3.35 (84.99mm) 2.55 (64.69mm) 2.87 (72.77mm) (70.35mm) 1.10 (28.02mm) 3.24 (82.23mm) Front View Right View Bottom View STANDARD ORDERING Example: A/CTE2-50 -OR A/CTE2-50 A/CTE2-150 A/SCTE2-50 A/SCTE2-150 A/SCTE2-250 A/CTV2-50 A/CTV2-150 A/SCTV2-50 A/SCTV2-150 A/SCTV2-250 Item # Selectable Ranges 0 to 50/100/150A 0 to 50/100/150A 0 to 100/200/250A 0 to 50/100/150A 0 to 50/100/150A 0 to 100/200/250A Measurement AC Waveform Output Signal 0 to 5 VDC 0 to 5 VDC 0 to 5 VDC 0 to 5 VDC 0 to 5 VDC 0 to 10 VDC 0 to 10 VDC 0 to 10 VDC 0 to 10 VDC 0 to 10 VDC The Voltage Output Current Sensors are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
10 Automation Components, Inc. CURRENT MINIATURE ADJUSTABLE CURRENT SWITCHES MINI ADJUSTABLE SWITCHES MCS-A & MSCS-A Series The Miniature Adjustable Current switches are designed for use in any AC current monitoring application in which you are looking for an adjustable current switch to monitor normal operating conditions, equipment failure or preventative maintenance scheduling for a particular piece of equipment. The adjustable current switches should be installed on the line side of the power to the motor, pump, compressor or other equipment. The miniature adjustable current switches are available in both solid and split-core versions in a smaller enclosure style than that of the A/ACS2 and A/ASCS2 Series adjustable current switches. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern. The split-core version of the current switches work great in retrofit applications and for use in service vehicles since one part will work in most applications and can be installed without disconnecting any wires. The adjustable current status switches can also be used to determine the run time of your equipment where you want to know when your piece of equipment runs and for how long it runs when logging the contact closures on your building management system or PLC. Applications: Overload Conditions, Under Load Conditions, Normal Load Conditions, Broken Belts, Belt Slippage, Locked Rotors, Electrical Failure, Load Status, Local Alarms such as Strobes/Audible Alarms, Pumps, Fans, Compressors, Lighting Status and Usage Information, Ovens, Process Control, Industrial Equipment, Equipment Maintenance, OEM The Miniature Adjustable Current Switches are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: Maximum AC Voltage: Operating Frequency Range: Core Style: Sensor Power: Amperage Range: Isolation Voltage: Trip Point Style Adjustable Trip Point Range: Hysteresis: Contact Type: Contact Rating: Contact On Resistance Off Resistance: Response Time: Status LED Indication 1: Aperture Size (Diameter): Operating Temperature Range: Operating Humidity Range: Recommended Storage Temperature RH Range: Enclosure Material Flammability Rating: Wiring Connections: Wire Size: Terminal Block Torque Rating: Minimum Mounting Distance: Agency Approvals 2: Product Weight: Product Dimensions (L x W x H): AC Current 600 VAC 50/60 Hz and Versions available (See Ordering Grid) Induced from the Monitored Conductor (Insulated Conductors only) See Ordering Grid 2200 VAC Adjustable Trip Point See Ordering Grid 10% Trip Point, typical Normally-Open N/O 1A 36 VAC/VDC < 0.5 Ohms (tripped) > 1 Meg Ohms (Open) A/MCS-A: < 90 ms, typical A/MSCS-A: < 45 ms typical Red LED (Current above trip point) Blue LED (Current below trip point) 0.53 (13.46 mm) -22 to 140ºF (-30 to 60ºC) 0 to 95%, non-condensing 41 to 95 F (5 to 35 C) 40% to 85% RH, non-condensing PC/ABS (Polycarbonate/ABS Blend) UL94-V0 2 Position Screw Terminal Block (Not Polarity Sensitive) 16 to 22 AWG (1.31 mm2 to 0.33 mm2) Copper Wires only 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) 1 (2.6 cm) between current switch (Relays, Contactors, Transformers) UL/CUL US Listed (UL 916) Energy Management Equipment (File # E334792), CE, RoHS2, WEEE A/MCS-A: 0.15 lbs. (0.068 kg) A/MSCS-A: 0.20 lbs. (0.091 kg) A/MCS-A (): (63.82 mm) x (23.94 mm) x (50.80 mm) A/MSCS-A (): (67.19 mm) x (23.94 mm) x (60.49 mm) Note1: The LED should not be used to determine if current is present. At low currents the LED may not be visible Note2: Maximum wire length not to exceed 98.4 Feet (30 meters) in order to meet the CE Requirements Call: Web: CURRENT ##
11 CURRENT MINIATURE ADJUSTABLE CURRENT SWITCHES Automation Components, Inc. DIMENSIONAL DRAWING.99 (25.06mm) 1.99 (50.48mm) 2.01 (51.05mm) 2.51 (63.82mm) 1.82 (46.14mm).99 (25.06mm) 2.38 (60.49mm) 2.15 (54.49mm) 2.65 (67.19mm) Front View Right View Bottom View STANDARD ORDERING Example: A/MCS-A -OR A/MCS-A A/MSCS-A Item # Trip Point Type Adjustable Adjustable N/O Amp Range 0.32 to 150A 0.70 to 150A Trip Point 0.32 to 150A 0.70 to 150A Contact Rating 36 VAC/VDC 36 VAC/VDC Note: The Miniature Adjustable Current Switches are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
12 Automation Components, Inc. CURRENT MINIATURE FIXED STATUS MINI FIXED STATUS MCS & MSCS Series The Miniature Fixed Current Status Switches are designed for use in any AC current monitoring application in which you are looking for a fixed trip point to monitor the Go/No Go (On/Off) Status for a particular piece of equipment. The fixed current switches should be installed on the line side of the power to the motor, pump, compressor or other equipment. All of the miniature current switches are available in both solid and split-core versions in a smaller enclosure style than that of the A/CS2 and A/SCS2 Series fixed current switches rated for higher operating currents. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern. The split-core version of the current switches work great in retrofit applications and for use in service vehicles since one part will work in most applications and can be installed without disconnecting any wires. Fixed status switches can also be used to determine the run time of your equipment when logging the contact closures on your building management system or PLC. Applications: On/Off Status Indication, Local Alarms such as Strobes/Audible Alarms, Pumps, Fans, Compressors, Lighting Status and Usage Information, Ovens, Process Control, Industrial Equipment, OEM Opportunities The Miniature Fixed Current Status Switches are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, PRODUCT SPECIFICATIONS Monitored Current Type: Maximum AC Voltage: Operating Frequency Range: Core Style: Sensor Power: Amperage Range: Isolation Voltage: Trip Point Style Adjustable Trip Point Range: Contact Type: Status Contact Rating: Status Contact On Resistance Off Resistance: Response Time: Status LED Indication 1: Aperture Size (Diameter): Operating Temperature Range: Operating Humidity Range: Recommended Storage Temperature RH Range: Enclosure Material Flammability Rating: Wiring Connections: Wire Size: Terminal Block Torque Rating: Minimum Mounting Distance: Agency Approvals 2: Product Weight: Product Dimensions (L x W x H): AC Current 600 VAC 50/60 Hz and Versions available (See Ordering Grid) Induced from the Monitored Conductor (Insulated Conductors only) See Ordering Grid 2200 VAC Fixed Trip Point See Ordering Grid Normally-Open N/O 0.5A 36 VAC/VDC < 0.5 Ohms (tripped) > 1 Meg Ohms (Open) A/MCS: < 50 ms typical A/MSCS: < 40 ms typical Red LED (Current above trip point) Blue LED (Current below trip point) 0.53 (13.46 mm) -22 to 140ºF (-30 to 60ºC) 0 to 95%, non-condensing 41 to 95 F (5 to 35 C) 40% to 85% RH, non-condensing PC/ABS (Polycarbonate/ABS Blend) UL94-V0 2 Position Screw Terminal Block (Not Polarity Sensitive) 16 to 22 AWG (1.31 mm2 to 0.33 mm2) Copper Wires only 4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm) 1 (2.6 cm) between current switch (Relays, Contactors, Transformers) UL/CUL US Listed (UL 916) Energy Management Equipment (File # E334792), CE, RoHS2, WEEE A/MCS: 0.15 lbs. (0.068 kg) A/MSCS: 0.20 lbs. (0.091 kg) A/MCS (): (63.82 mm) x (23.94 mm) x (50.80 mm) A/MSCS (): (67.19 mm) x (23.94 mm) x (60.49 mm) Note1: The LED should not be used to determine if current is present. At low currents the LED may not be visible Note2: Maximum wire length not to exceed 98.4 Feet (30 meters) in order to meet the CE Requirements Call: Web: CURRENT ##
13 CURRENT MINIATURE FIXED STATUS Automation Components, Inc. DIMENSIONAL DRAWING.99 (25.06mm) 1.99 (50.48mm) 2.01 (51.05mm) 2.51 (63.82mm) 1.82 (46.14mm).99 (25.06mm) 2.38 (60.49mm) 2.15 (54.49mm) 2.65 (67.19mm) Front View Right View Bottom View STANDARD ORDERING Example: A/MCS -OR A/MCS A/MSCS Item # Trip Point Type Fixed Trip Point Fixed Trip Point N/O Amp Range 0 to 150A 0 to 150A Trip Point 0.20A or less 0.55A or less Contact Rating 36 VAC/VDC 36 VAC/VDC Note: The Miniature Fixed Current Switches are not intended to be used in Life / Safety Applications or in Hazardous / Classified Locations Revision C Rev 1.0 CURRENT ## Call: Web:
14 Automation Components, Inc Pleasant View Road Middleton WI 53562
Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17
Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationDC Current Transducers
Current Transducers are designed to provide an analog current reading for monitoring, data logging and panel meter applications. NK Technologies current transducers offer a choice of 5 VDC, 1 VDC or ma
More informationAC Current Transducers
Current Transducers are designed to provide an analog signal proportional to the AC current for monitoring, data logging and panel meter applications. NK Technologies current transducers offer a choice
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationMODEL CTR - TRUE RMS AC CURRENT TRANSDUCER
Bulletin No. CTR- X Drawing No. LP0653 Effective 10/06 www.redlion.net MODEL CTR - TRUE RMS AC CURRENT TRANSDUCER TRUE RMS OUTPUT JUMPER SELECTABLE RANGES OUTPUT IS MAGNETICALLY ISOLATED FROM THE INPUT
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationCPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A
The CPCO Series (160mm aperture) Current Probes are Clamp On current sensors capable of measuring ac and dc currents. The Current Probe splits along a diameter allowing easy installation to existing cables
More informationCSI 9330 Vibration Transmitter
Machinery Health Management O-9330-110512 Product Data Sheet November 2012 CSI 9330 Vibration Transmitter n Continuously monitors critical machinery in process applications and other industrial environments
More information9330 Vibration Transmitter
Reliability Solutions Product Data Sheet June 2017 9330 Vibration Transmitter Continuously monitors critical machinery in process applications and other industrial environments Interfaces with existing
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More informationCPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,
The CPCO Series (160mm) Current Probes are Clamp On current sensors capable of measuring ac and dc currents available in ranges of ±4000A ±8000A, ±12000A with an accuracy of +/-1% and non-linearity of
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationINSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.
INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA
More informationImprove asset protection and utilization
QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause
More informationSwitching Power Supply Type SPP1 60W Enclosed type
Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationInstallation Instructions Space Temperature Transmitter
Installation Instructions Space Temperature Transmitter Catalog Number(s) 1414-CTZ03PBRAA, 1414-CTD03PBRAA, 1414-CTO03PBRAA, 1414-CTS03PBRAA, 1414-CTT03PBRAA, 1414-ITS03PBRAA, 1414-ITT03SBRAA, 1414-ITZ02GBRAA,
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationTS-700/1000 INVERTER Instruction Manual
TS-700/1000 INVERTER Instruction Manual TS-700/1000 Instruction Manual Index 1. Safety Guidelines... 1 2. Introduction... 1 2.1 Features... 1 2.2 Main Specification... 2 3. User Interface... 2 3.1 Front
More informationDXM 300W-1200W X-RAY GENERATOR MODULE REV. AB
PAGE 1 OF 5 Compact & Lightweight Models from 20kV-160kV, 300W, 600W and 1200W Universal Input, Power Factor Corrected Hot Anode or Hot Cathode X-Ray Tube Capable Standard Digital Interfaces:, Ethernet
More information3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays
.6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60
More informationAdvanced, accurate and intelligent monitoring for your transformer
QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal
More informationRN Thyristor Controllers
Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they
More informationHigh Frequency Sinewave Guardian TM Filter
High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More informationPKG-171-MBC25-PS-CBL System Diagram and Specifications
PKG-171-MBC25-PS-CBL System Diagram and Specifications Included Components: 17Y102S-LW4-MS Stepper Motor MBC25081TB Stepper Driver PSAM24V2.7A Power Supply CBL-20AWG-04C-010-MS Motor Cable CBL-AA4366 Power
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationHigh Frequency SineWave Guardian TM Filter
High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference
More informationSingle or parallel use selectable by user Adjustable output voltage. New narrow width saves panel space
4 Power Supplies The SolaHD Difference Rugged metal packaging Multiple output connections for ease of wiring multiple devices New visual diagnostic LEDs show input and output status (see table below) Large,
More informationUSER S MANUAL. 1KSS60400/ ST Edition
USER S MANUAL 1KSS60400/50400 1 ST Edition Frequency Converter Visicomm Industries LLC 911A Milwaukee Ave. Burlington, WI 53105 1. INTRODUCTION The conversion of electrical power is an essential requirement
More informationP1-04DAL-1 Analog Output
Output Specifications Output Channels Output Range ma Signal Resolution -bit Resolution Value of SB (least significant bit) Data Range 9 counts Output Type Output Value in Fault Mode ess than ma oad Impedance
More informationNon-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
More informationVariable Speed Brushed DC Motor Drive
The driving force of motor control & electronics cooling. Equinox: Variable Speed Brushed DC Motor Drive Navigator Equinox The Equinox variable speed brushed DC motor drive with Navigator Programmer is
More informationRelated Products SDP Series SFL Series SCP Series SCL Series SDU UPS
4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility
More informationTxBlock-USB Transmitter
Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is
More informationACS600, ACS800. Installation Guide
ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationProduct Data Sheet 3252J/2H3PU
3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3
More informationHI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date
Last Amended on - Page 1 of 14 I. AUDIO EQUIPMENT 1. Audio-Video and Similar Electronics Apparatus Safety Requirement Marking & Instructions Laser Radiation (Products Marked Class I only) Heating under
More informationI Pr I P I OUT R L. Applications. Standards
Ref: ATO-XXX-B225-D10 I Pr = 10, 15, 16, 20, 30, 32, 50, 60, 63, 75 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More informationVARIABLE FREQUENCY DRIVE SPECIFICATION
VARIABLE FREQUENCY DRIVE SPECIFICATION 1.0. SUMMARY The use of variable frequency drives (VFDs) in conjunction with wastewater lift stations has been identified as a means improve efficiency and to moderate
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationCEC VIBRATION TRANSMITTER
CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:
More informationSoftstarters. Specification guide. Type PST. Low Voltage Products & Systems
Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification
More informationGE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.
GE Fanuc Automation Programmable Control Products Stepping Motor Cube with Pulse and Direction Interface User s Manual July 2002 GE FANUC Spares Warnings, Cautions, and Notes as Used in this Publication
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationD SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE
D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS
Zlinx Wireless Modbus I/O-0712ds page 1/5 Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationDeploying Current Transformers in Applications Greater Than 200 A
Deploying Current Transformers in Applications Greater Than 200 A Andrew Schaeffler Step-down Current Transformers (CTs) are common, and useful, in large motor applications. They provide isolation between
More informationMODEL 140 VIBRATION TRANSMITTER
OPERATION MANUAL MODEL 140 VIBRATION TRANSMITTER Includes 140-1, -2, -5, -X and 140-T-1, -2, -5, -X Page 2 MODEL 140 TABLE OF CONTENTS 1. INTRODUCTION... 3 Description... 3 2. FEATURES... 3 Piezoelectric
More informationTo be automatically connected to the nearest North American Technical Sales Office:
DIN-A-MITE C SCR Power Controller Delivers Up To 80 Amperes in a Compact Package TOTAL CUSTOMER SATISFACTION 3 Year Warranty The Watlow DIN-A-MITE Style C silicon controlled rectifier (SCR) power controller
More informationP1-04ADL-2 Analog Input
Input Specifications Input Channels Input Range VDC Signal Resolution -bit Resolution Value of SB (least significant bit) Data Range Input Type Maximum Continuous Overload ±VDC Input Impedance kω Hardware
More informationDDC control of package units, heat pumps, unit ventilators, and other terminal unit applications
Infinity TCX 867 Terminal Control Unit F E A T U R E S The Infinity TCX 867 programmable controller is a compact terminal control unit that provides lowcost DDC control of package units, heat pumps, unit
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationNon-Spring Return DuraDrive Modulating Actuator
MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries
More informationElectronic relays. Monitoring. Monitoring
Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationPKG-341-MLA-CBL System Diagram and Specifications
PKG-341-MLA-CBL System Diagram and Specifications 600 34Y112S-LW8, MLA10641, Div by 16, 120VAC, Series 400 Included Components: 540 360 34Y112S-LW8-MS MLA10641 CBL-18AWG-04C-010-MS PWR-10EMC1 LIN-AA4254
More information847H. Description. Features. Specifications
847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536
More informationVFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.
VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload
More informationcurrent transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart
NK Technologies ADC series signal converters use sensor outputs (4 0 ma, 0 5 and 0 10 VDC) and convert these to digital RS485 outputs. The CTC series accept either 5 A secondary current from Analog to
More informationThe SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC
The SSR P Series Phase-Fired SCR Power Controllers 15-70 AMPS 80-600 VAC Phase-Fired SCR Power Controllers for resistive heating loads. ROBICON 1996 Rev. 12/96 Applications The SSR P series models are
More informationHLC-1000 High-limit Humidity Control
FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationNon-Spring Return EconoDrive Proportional Actuator
MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationULTRASTAB I U Precision
ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation
More informationHexa Multi Module 366HMM. Introduction. Design Specifications. Key Features
Hexa Multi Module Introduction The E-Plex 366HMM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total. The six channels can be utilized as either
More informationAnalogue temperature controllers
Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationCD-Pxx-00-0 Series Duct Mount CO 2 Transmitter
Installation Instructions CD-Pxx-00-0 Issue Date February 4, 006 CD-Pxx-00-0 Series Duct Mount CO Transmitter Application Requirements FCC Compliance Statement This equipment has been tested and found
More informationFLEXIBLE CURRENT PROBES
FLEXIBLE CURRENT PROBES AmpFlex, LongLife AmpFlex & FlexProbe Ranges from 30 to 30,000Arms (AmpFlex Flexible Current Probes) Single or dual range to measure up to 3000A (LongLife AmpFlex Flexible Current
More informationI P I OUT R L. Applications. Standards. N 52.D ; Page 1/8
Ref: ATO-10-B225-D10/SP3 r = 10 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MEMFLO MFT2 2-WIRE FLOW TRANSMITTER (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 DESCRIPTION Please read carefully! No liability can
More informationCSD Series Current Devices Solid Core with Relay
CSD Series Current Devices Solid Core with Installation Instructions CSD-SA1E1-1 CSD-SA1E2-1 Part No. 24-10345-26, Rev. F Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationOPERATOR S INSTRUCTION MANUAL
2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY
INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationLDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.
LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes
More informationUSER S MANUAL. 3KSS6050/ nd Edition
USER S MANUAL 3KSS6050/5060 2 nd Edition Frequency Converter Visicomm Industries LLC 4525 Sheridan Rd. Racine WI 53403 1. INTRODUCTION The conversion of electrical power is an essential requirement for
More informationWorld-Class Accuracy & Measurement Range (40 Conventional Models)
AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)
More informationTorque Sensor Accessories and Services
------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationSolid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.
Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection Product Width ranging from 17.5mm up to 70mm Rated Operational voltage: Up to 600VAC Rated Operational current: Up to 85AAC
More informationPRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER
JRF333M-X 333mVAC 24VDC, 2VA S1 S2 Vin + Vin - PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER LED SINGLE PHASE output 333mV AC THREE PHASE output 333mV AC Power isast OPEN RCT is made with
More informationMS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.
MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationOptions & Accessories
75 mm (2.95-inch) BLDC Motor with Integrated Sensorless Digital Drive Allied Motion s Gen III EnduraMax 75s series motors are 75 mm (2.95 in) diameter brushless DC motors that incorporate integrated drive
More informationSWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved
More information