1 (sold pre-paired) Installation Guide Industrial Wireless ZigBee Relay ILLUMRA Relay Receivers should NOT be installed in a location where the unit will be in close proximity to the light bulb(s) or other sources of heat, such as above a ceiling hugger fixture, particularly with higher wattage loads. (See Operating Temperature on specifications table.) Exceeding the voltage or current ratings of the IWR will void the warranty and may damage the unit. For optimal radio performance do not mount or place receivers close to the floor or inside a metal housing. Step 1: Connect the power supply to the power terminals of the Industrial Wireless Relay (IWR). Step 2: Reference the IWR Wiring Diagram (Figure A) for appropriate wiring. Step 3: Review and adjust jumper locations (Figure B) as necessary. The jumpers are located inside the device and are accessed by removing the four screws securing the cover. The jumpers are set at the factory in the most common configuration, but can be customized in the field to suit a wide variety of wiring scenarios, including solar powered applications. Diagrams Figure INDUSTRIAL A: Network Diagram RELAY Overview UNIT A 1 MILE UNIT B The Industrial Wireless Relay (IWR) provides long range control I/O devices (such as lights, switches, sensors, pumps, fans, PLCs, etc.). Control inputs are compatible with either dry contacts or DC signal voltages, logic signals, etc. In an ILLUMRA Hybrid: EnOcean + ZigBee system, the IWR is connected to ILLUMRA 4 Channel Low Voltage Relay Receivers (E3R-R04FP-4). Compatible Devices Any Low Voltage Wiring Device Most Wired Sensors Most Load Types Components Included The following items are included with this product: (2) ILLUMRA Industrial Wireless ZigBee Relay ANY 8-28VAC OR 8-30VDC (SOLD SEPARATELY) 8-30VDC 8-28VAC V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY LOAD (FLASHLIGHT BULBS SHOWN). LD-1A ANY 8-28VAC OR 8-30VDC (SOLD SEPARATELY) 8-30VDC 8-28VAC V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY LOAD (FLASHLIGHT BULBS SHOWN). LD-1B Required Power Supply (Not Included) Power Pack w/ Relay (NWO-R12-R27NP) 120, 220, or 277VAC. Outputs 24VDC Wall Adapter (NWO-P9VPG). Output 9VDC Any 8-28VAC or 8-30VDC Power Adapter Optional Accessories 2.4 GHz - 7dbi gain WiFi Antenna (articulating joint) Part # A24-7ACRSM Non-metallic NEMA Enclosure for weather-proofing DRY CONTACTS (OR DC S, SEE NOTE 1) ACTIVATE THE INPUTS. SW-1A SW-2A SW-3A * SW-4A LD-2A LD-3A LD-4A DRY CONTACTS (OR DC S, SEE NOTE 1) ACTIVATE THE INPUTS. SW-1B ** SW-2B SW-3B SW-4B LD-2B LD-3B LD-4B Installation To install the Industrial Wireless Relay (IWR), follow the directions below. See wiring diagrams for installation examples. CAUTION/NOTES: Always follow local electrical codes when installing this device. Installation should be performed by a qualified electrician. ILLUMRA IWR s are intended only for use indoors, in dry locations, and with permanently installed fixtures. NOTE 1. IF AN INPUT IS ACTIVATED WITH A DC, CONNECT THE NEGATIVE SIDE TO GND (LOCATED BETWEEN IN3 AND IN4) AND CONNECT THE POSITIVE SIDE TO THE INPUT (IN1, IN2, IN3, OR IN4). REVERSE POLARITY MAY CAUSE DAMAGE TO THE UNIT. NOTE 2: INTERNAL JUMPERS AL USER TO CONFIGURE EACH DEVICE. SEE JUMPER TABLE IN USER MANUAL. OUTPUTS ON "UNIT A" ARE LED BY CORRESPONDING INPUTS ON "UNIT B". **NOTE: LD-2A IS ON, BECAUSE INPUT 2 ON "UNIT B" IS ACTIVATED BY SW-2B. OUTPUTS ON "UNIT B" ARE LED BY CORRESPONDING INPUTS ON "UNIT A". *NOTE: LD-4B IS ON, BECAUSE INPUT 4 ON "UNIT A" IS ACTIVATED BY SW-4A.

2 Figure B: Default Jumper Location and Table P4 internal 3.3VDC regulated supply and external 3.3VDC supply EXT. INT. (default) Device uses a ground provided externally. Device MUST be powered from a REGULATED VDC supply! Correct polarity MUST be observed! Device can be powered from any external 8-30VDC or 8-28VAC supply. Polarity insensitive Use extreme caution in this position. If the supply voltage exceeds 3.3VDC, the device will be damaged! Useful in battery/solar powered installations where minimum quiescent current is a requirement. P3 must also be in EXT. GND position. Polarity of regulated 3.3VDC power must be applied properly or damage will result (see wiring diagram). Normally, this position is used. P5 P6 P7 P8 internal pull-up or pull-down on input 1, 2, 3, or 4 (respectively) PULL-UP PULL-DOWN (default) Pulls-up input Pulls-down input. Connect dry contact GND and IN1. Alternatively, the input can be driven with a DC voltage in the range 0-1VDC (TTL and CMOS compatible). Connect dry contact +3.3V and IN1. Alternatively, the input can be driven with a DC voltage in the range 3-30VDC (TTL and CMOS compatible). JUMPER PURPOSE POSITIONS FUNCTION NOTES, CAUTIONS, WARNINGS GND (default) enabled are enabled all the time and will illuminate when and input/output is active P1 Enable / disable LED indicators LED Not Installed disabled disconnected are disabled, but will briefly illuminate during radio transmissions LED indicator will never illuminate, which is useful in applications where minimum power consumption is desired (i.e. battery-powered / solar-powered installations). P2 Reserved for future use Not installed Not installed Reserved for future use Reserved for future use P3 internal ground and external ground EXT. GND Device uses a ground provided externally. Device MUST be powered from a REGULATED VDC supply! Correct polarity MUST be observed! Use extreme caution in this position. If the supply voltage exceeds 3.3VDC, the device will be damaged! Useful in battery/solar powered installations where minimum quiescent current is a requirement. P4 must also be in EXT. position. Polarity of regulated 3.3VDC power must be applied properly or damage will result (see wiring diagram). INT. GND (default) Device uses its own internal ground. Polarity insensitive Normally, this position is used. 2

3 Figure C: Long Range Egress Lighting w/ 15 Minute Auto Off Timer Figure D: Long Range Gate Motion Control EGRESS LIGHTING WITH 15 MIN. AUTO-OFF TIMER AC 120V AC OUT 3 OUT 2 OUT 1 ON IN 1 GND VCC E3R-MICFP-13 S 1 MILE LINE-0F-SIGHT LINE-OF-SIGHT AC 120V OUT BUILDING #1 AC SWITCH ON AC 120V OUT BUILDING #2 AC ON BREAKER PANEL BREAKER PANEL BREAKER PANEL OUT BUILDING #1 OUT BUILDING #2 LY LIGHTS USING MOTION SENSOR MOUNTED NEAR THE GATE TO THE PROPERTY. MOUNTS NEAR GATE ON AC 277V AC 120V AC OPTIONAL SECONDARY LIGHT FIXTURE NEAR GATE MOUNTS ON AC 277V AC 120V AC IN OUT BUILDING #1 IN OUT BUILDING #2 AC AC SWITCHED OUTPUT OPTIONAL WIRELES LOCAL SWITCH MOTION SENSOR MOUNTED NEAR THE ENTRANCE GATE TURNS ON A LIGHT AT THE GATE, WHICH TRIGGERS SYSTEM TO SEND A TO THE, WHERE LIGHT(S) MOUTED IN THE ALSO TURN ON. E3R-R12-5IBBP ANY INTEGRATED LIGHT OPTIONAL WI SWITCH AT ALS LIGHTS FIXTURE / MOTION SENSOR TO TO BE TURNED ON LOCALLY. TO TURN LIGHT OFF, LOCAL SWITCH AND MOTION BREAKER PANEL #2 NEAR GATE SENSOR MUST BOTH BE OFF. OPTIONAL SWITCH AT ALS LIGHTS IN MAIN BUILDING TO TO BE TURNED ON LOCALLY. TO TURN LIGHT OFF, LOCAL SWITCH AND MOTION SENSOR MUST BOTH BE OFF. COM. 1 MILE ON AC 277V AC 120V AC OPTIONAL WI LOCAL SWITCH OFF 3

4 Figure E: 8 Long Range Wireless Control of Lighted Sign Figure F: Wireless Control of Lights in Out Building LY A REMOTE LOAD, SUCH AS A LIGHTED SIGN MOUNTS IN REMOTE LOCATION MOUNTS NEAR LIGHTED SIGN ON WALL WART SUPPLY PLUGS INTO A SWITCHED OUTLET. WHEN THE OUTLET IS ON, THE LIGHTED SIGN WILL BE ON. WHEN THE OUTLET IS OFF, THE LIGHTED SIGN WILL BE OFF. AC 277V AC 120V AC REMOTE LOAD / LIGHTED SIGN A NO1 COM1/2 IN1 CONNECTED TO +3.3V LIGHTS IN OUT BUILDING WITH SYSTEM E3T-S2AWH MOUNTS E3R-R04FP-4 R1 R2 R3 R4 MOUNTS IN OUT BUILDING NWO-2401B-NP SWITCHES LV MOUNTS / HV / BATTERY FREE LIGHT SWITCHES THE LIGHTS IN TWO ZONES IN THE OUT BUILDING FROM TWO LOCATIONS WITHIN THE. THE LIGHTS IN THE OUT BUILDING CAN ALSO BE LED FROM WITHIN THE OUT BUILDING USING BATTERY-FREE LIGHT SWITCHES ORANGE OUT BUILDING AC AC AC AC NWO-2401B-NP LV / HV / E3R-R12-5IBBP ORANGE E3R-R12-5IBBP OUT BUILDING 4

5 Figure G: Long Range Control of Tennis Court Lights from Pro-shop with Local Contactors TENNIS COURT #1 TENNIS COURT #2 TENNIS COURT #3 TENNIS COURT #4 Specifications MOUNTS IN PANEL NEAR COURTS Range, Typical Operating Frequency Transmit Power Power Supply Input Rating Relay Output Rating up to 1 mile (RF line-of-sight) w/ optional high gain antenna up to 1,000 ft. (Residential) up to 300 ft. (urban/industrial) 2.4 GHz (DSSS - Direct Sequence Spread Spectrum) 60mW (100mW EIRP w/ included antenna) 8-30 VDC, 8-28 VAC (3.3 V option available see installation guide) 4 Each: 2A, 0-30 VAC or VDC, Form A (normally open, SPST) Interface 4 Each: Inputs - dry or wet contact. Outputs - dry contact (see installation guide) Typical Latency 5 ms (input to output units) AC 277V AC 120V AC AC 277V AC 120V AC AC 277V AC 120V AC AC 277V AC 120V AC Polling Update Rate Receiver Timeout Typical Supply Current 1 second 10 seconds (if connection is lost for this long, all relays will open) 18 ma min, 120 ma max LIGHTS ON TENNIS COURTS WITH SYSTEM E3T-S2AWH MOUNTS IN PRO-SHOP MOUNTS IN PANEL NEAR COURTS E3R-R04FP-4 R1 R2 R3 R4 MOUNTS IN PANEL NEAR COURTS SWITCHES ON MOUNTS IN PRO-SHOP BATTERY FREE LIGHT SWITCHES THE LIGHTS ON EACH OF FOUR TENNIS COURTS FROM WITHIN THE PRO SHOP. SWTICHES ARE MOUNTED NEAR THE SALES COUNTER IN THE PRO SHOP. ON ON ON Operating Temperature Storage Temperature Dimensions Radio Certifications Warranty Please refer to for updated warranty information -22 F to 140 F (-30 C to 60 C) -40 F to 140 F (-40 C to 60 C) 4.2 (W) x 2.8 (H) x (D) or 10.7cm x 7.2cm x 2.9cm FCC: OUR-XBEEPRO, IC: 4214A-XBEEPRO This device or certain aspects thereof is protected by at least one U.S. or international patent or has at least one such patent application pending. ILLUMRA is a trademark of Ad Hoc Electronics, LLC. Other trademarks herein are the property of their respective owners. 5

www.greenelectricalsupply.com Installation Guide Model: WLVD Wireless Low Voltage Dimmer (Receiver) Specifications: Power Supply 24 V DC Place on 24V power line prior to light load. 10A Maximum Load Package

More information

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The switch followers are a two way system designed to provide a quick and cost effective

More information

IRRIGATION 810-3R RECEIVER GUIDE

IRRIGATION 810-3R RECEIVER GUIDE IRRIGATION 810-3R RECEIVER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 RECEIVER FUNCTION SWITCH SETTINGS 4 RECEIVER INDICATOR LIGHTS 4 SUPERVISION FEATURE 5 RECEIVER HOOKUP TO ENGINE DRIVEN WELL 6 RECEIVER HOOKUP

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to

More information

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The SF900C Series Remote Control/Switch Followers are a twoway system designed to

More information

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3. Rev 3.5 I n s t a l l a t i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Shop for The Energy Detective products online at: 1.877.766.5412 IMPORTANT: The installation of your TED

More information

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0 I n s t a l l a t i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0 IMPORTANT: The installation of your TED Pro Home system is a several-step process. The 1st step is the installation

More information

Wireless Ceiling Mount Sensor

Wireless Ceiling Mount Sensor Wireless Ceiling Mount Sensor Lutron s occupancy and vacancy sensors are wireless ceiling-mounted battery-powered passive infrared (PIR) sensors that automatically control lights via RF communication to

More information

802.11g Wireless Sensor Network Modules

802.11g Wireless Sensor Network Modules RFMProducts are now Murata Products Small Size, Integral Antenna, Light Weight, Low Cost 7.5 µa Sleep Current Supports Battery Operation Timer and Event Triggered Auto-reporting Capability Analog, Digital,

More information

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions Ver. 1.01 Section 1 General Description Camden Lazerpoint Radio Controls comprise the following models: - CM-TX-9 Wall switch ready transmitter

More information

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.02 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

User Manual. ProRF Encoder Transmitter & Receiver

User Manual. ProRF Encoder Transmitter & Receiver User Manual ProRF Encoder Transmitter & Receiver WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original

More information

Operations Manual Edition 3.1

Operations Manual Edition 3.1 Operations Manual Edition 3.1 MREL GROUP OF COMPANIES LIMITED 1555 Sydenham Road, Kingston, Ontario K7L 4V4 Canada T: +1-613-545-0466 F: +1-613-542-8029 E: blasting@mrel.com www.mrel.com ii Copyright Information

More information

Setup Guide. support.spruceirrigation.com.

Setup Guide. support.spruceirrigation.com. FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device

More information

P700WLS IoProx Receiver

P700WLS IoProx Receiver Installation Manual Warning! This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual

More information

Wireless Analog/Digital Link NEMA 4x Transmitter/DIN-rail Receiver Set

Wireless Analog/Digital Link NEMA 4x Transmitter/DIN-rail Receiver Set Wireless Analog/Digital Link NEMA 4x Transmitter/DIN-rail Receiver Set August 2003 Features Wireless conduit for one 4-20 ma and two digital signals Weatherproof NEMA 4x (equivalent to IP65) housing Range:

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

Super Switch Indoor Wireless Remote Control Wall Outlets

Super Switch Indoor Wireless Remote Control Wall Outlets Super Switch Indoor Wireless Remote Control Wall Outlets The Remote Control for Living Room, Kitchen & Bedroom Lights, Lamps, Fans and More Item/Art. 770742 Model #: SSW2-3-3322 Set of (3) Indoor Outlets

More information

Tower Light with Wireless Switch Control Box

Tower Light with Wireless Switch Control Box Series: WTLBC Tower Light with Wireless Switch Control Box FEATURES & BENEFITS License Free Wireless Control Up To 1 Mile Line-of-site. Stacks with Green, Yellow, Red, Blue or White Lights Attached or

More information

PIM400-TD2. User guide for Panel Interface Module PIM400-TD2

PIM400-TD2. User guide for Panel Interface Module PIM400-TD2 P516-096 PIM400-TD2 User guide for Panel Interface Module PIM400-TD2 Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française, veuillez consulter le site www.schlage.com/support

More information

RAIN-CLIK. Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems. Owner s Manual and Installation Instructions

RAIN-CLIK. Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems. Owner s Manual and Installation Instructions RAIN-CLIK Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems Owner s Manual and Installation Instructions For use with WR-CLIK and WRF-CLIK Sensors TABLE OF CONTENTS Features...3

More information

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications Features 1,2,4 or 8 Channel Systems 12 / 24Vdc or 230Vac Supply Range FireFly up to 100 metres FireBlade up to 1,000 metres Reliable FM Technology High Security RF Protocol Easy Learn Tx Encoder Feature

More information

UN2 - Universal controller Building automation s missing link

UN2 - Universal controller Building automation s missing link Building automation s missing link Introduction A flexible line of controllers that allows facility managers, contrac - tors and OEM manufacturers to deploy integrated solutions for HVAC, lighting, and

More information

Wireless Magnet Detection Sensor

Wireless Magnet Detection Sensor The Leader in Low-Cost, Remote Monitoring Solutions Wireless Detection Sensor MAGNET DETECTION General Description The Wireless Detection Sensor can be used to detect the presence of a magnetic source

More information

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

Dialight Daylight Harvesting Sensor User Guide

Dialight Daylight Harvesting Sensor User Guide Daylight Harvesting Sensor Dialight Daylight Harvesting Sensor User Guide Dialight Catalog Number: DLHU124UG2 1 Safety Instructions Dialight Daylight Harvester Sensor (DLH) User Guide READ AND FOLLOW ALL

More information

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LRF20CR2BPWH Lutron Occupancy Sensor 1 Way FM 434 R2 Lutron Catalog Number Manufacturer Description Weight per unit Product

More information

Antenna Basics. Antennas. A guide to effective antenna use

Antenna Basics. Antennas. A guide to effective antenna use A guide to effective antenna use Antennas Antennas transmit radio signals by converting radio frequency electrical currents into electromagnetic waves. Antennas receive the signals by converting the electromagnetic

More information

Operating Instructions

Operating Instructions LR650 Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all

More information

Wireless Activity Sensors

Wireless Activity Sensors The Leader in Low-Cost, Remote Monitoring Solutions Wireless Activity Sensors General Description Monnit wireless activity sensors can be used in a host of applications where detecting vibration (sudden

More information

P700-WLS ioprox Receiver

P700-WLS ioprox Receiver Installation Manual DN1628-1611 Pre-Installation Notes Copyright 2016 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and

More information

Receiver 10-5 BER -100 dbm Transmitter RF Output Power 1 10 or 63 mw mw Antenna Impedance 50 Ω

Receiver 10-5 BER -100 dbm Transmitter RF Output Power 1 10 or 63 mw mw Antenna Impedance 50 Ω - 2.4 GHz Frequency Hopping Spread Spectrum Transceivers - Direct Peer-to-peer Low Latency Communication - Transmitter RF Power Configurable - 10 or 63 mw - Transmitter EIRP 15.8 mw or 100 mw with 2 dbi

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

GV-RU9003 UHF RFID Reader

GV-RU9003 UHF RFID Reader GV-RU9003 UHF RFID Reader Introduction GV-RU9003 is a Radio Frequency Identification (RFID) reader of ISO18000-6C (EPC GEN2) standard. Designed for parking lot management, the reader can read RFID tag

More information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information IMPORTANT! Visit http://support.proxim.com for the latest safety and regulatory compliance information for this product. ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications Multilin DGT Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators The desire for green power and rapid developments in renewable energy sources are driving the growth of distributed

More information

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor Lutron Catalog Number Manufacturer Description Weight per unit Product Category

More information

Technical Application Guide

Technical Application Guide Lighting Control Wireless Occupancy Sensor, Wireless Multi Sensor Technical Application Guide Easily enhance your smart lighting system with the Philips wireless occupancy sensor and multi sensor, which

More information

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement Modbus ASCII /RTU Compatible Wide Operating Temperature Active Repeater Functionality 10 to 48 VDC & 24 VAC Input Power Zlinx Wireless Modbus I/O - flexible enough

More information

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery Node with an integrated battery for the EZ-LIGHT family 900 MHz, Internal battery model Features The SureCross DX80 is a radio frequency network

More information

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com

More information

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O 2.4 GHz Frequency Hopping Spread Spectrum Transceiver Point-to-point, Point-to-multipoint, Peer-to-peer and Tree-routing Networks Transmitter Power Configurable from 1 to 63 mw RF Data Rate Configurable

More information

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz. RF Chip Rate 11 Mcps RF Data Rates 1, 2, 5.

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz. RF Chip Rate 11 Mcps RF Data Rates 1, 2, 5. RFM Products are now Murata products. Small Size, Light Weight, Low Cost 7.5 µa Sleep Current Supports Battery Operation Timer and Event Triggered Auto-reporting Capability Analog, Digital, Serial and

More information

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter WRZ-RMT10K-0 Wireless Remote Temperature Transmitter Product Bulletin WRZ-RMT10K-0, TE-6361A-1, TE-6361V-2, TE-636GV-2, TE-636S-1 The WRZ-RMT10K-0 Wireless Remote Temperature Transmitter is designed to

More information

Radio Powr SavrT Occupancy / Vacancy Sensor

Radio Powr SavrT Occupancy / Vacancy Sensor 369480c 1 01.25.13 Radio Powr SavrT Occupancy / Vacancy Sensor LutronR Radio Powr SavrT occupancy/vacancy sensors are wireless, battery-powered passive infrared (PIR) sensors that automatically control

More information

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC IMPORTANT DISCLAIMER: Niether Heliotrack,LLC nor Inspeed assume any responsibility for damages caused by the

More information

www.greenelectricalsupply.com Wireless Wall-Mount Sensor Lutron wall-mounted occupancy and vacancy sensors are wireless, battery-powered, passive infrared (PIR) sensors that automatically control lights

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Wireless Temperature Sensor with Probe

Wireless Temperature Sensor with Probe The Leader in Low-Cost, Remote Monitoring Solutions Wireless Temperature Sensor with Probe TEMPERATURE 3 FOOT PROBE General Description The Wireless Temperature Sensor with Probe uses a type NTC thermistor

More information

ERM-DA. Installation Guide

ERM-DA. Installation Guide ERM-DA Installation Guide ERM-DA Product Overview Echoflex s ERM-DA is an active circuit transmitter that provides a low cost method of using a live electrical circuit as a switch. When the circuit is

More information

Wireless Temperature Sensor

Wireless Temperature Sensor The Leader in Low-Cost, Remote Monitoring Solutions Wireless Temperature Sensor General Description The Wireless Temperature Sensor uses a type NTC thermistor to measure temperature. Features Accurate

More information

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV INSTALLATION and OPERATION INSTRUCTIONS FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV Page 1 of 15 TABLE OF CONTENTS PARA No. PARAGRAPH PAGE No. 1. OVERVIEW 3 2. COMPONENT

More information

HORNET Remote Control Systems

HORNET Remote Control Systems HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching

More information

12V Victor 888 User Manual

12V Victor 888 User Manual The Victor speed controllers are specifically engineered for robotic applications. The high current capacity, low voltage drop, and peak surge capacity make the Victor ideal for drive systems while its

More information

AN0509 swarm API Country Settings

AN0509 swarm API Country Settings 1.0 NA-15-0356-0002-1.0 Version:1.0 Author: MLA Document Information Document Title: Document Version: 1.0 Current Date: 2015-04-16 Print Date: 2015-04-16 Document ID: Document Author: Disclaimer NA-15-0356-0002-1.0

More information

Wireless Gas Detection System

Wireless Gas Detection System Wireless Gas Detection System Sensidyne SensCast Brochure Rev.A Wireless Gas Detection System The Sensidyne SensCast Wireless Monitoring System consists of 1-32 battery-powered SensCast Transmitters and

More information

TOP VIEW. 6.75" (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285" (185mm) Battery Positive Terminal SIDE VIEW. 6.12" (155.

TOP VIEW. 6.75 (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285 (185mm) Battery Positive Terminal SIDE VIEW. 6.12 (155. Installation and Operation Instructions RR2552 Spread Spectrum Repeater TOP VIEW 6.75" (171.5mm) Network ID Selector Ø0.190 (4 PLCS.) Data Link LED 3.5" 4.72" (88.9mm) (119.89mm) Active LED Battery Positive

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS Zlinx Wireless Modbus I/O-0712ds page 1/5 Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII

More information

Sensor. Wireless WR-CLIK. WRF-CLIK Wireless Rain/Freeze-Clik. Rain Sensor Shutoff for Automatic Irrigation Systems

Sensor. Wireless WR-CLIK. WRF-CLIK Wireless Rain/Freeze-Clik. Rain Sensor Shutoff for Automatic Irrigation Systems Wireless RAIN LIKTM Sensor Rain Sensor Shutoff for Automatic Irrigation Systems Owner s Manual and Installation Instructions WR-CLIK Wireless Rain-Clik WRF-CLIK Wireless Rain/Freeze-Clik TABLE OF CONTENTS

More information

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor Radio Powr SavrTM Wireless Occupancy / Vacancy Sensor Lutron Radio Powr SavrTM occupancy/vacancy sensors are wireless, battery-powered, passive infrared (PIR) sensors that automatically control lights

More information

Wireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case.

Wireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case. MAN0783-01 15 JUN 2005 PAGE 1 This datasheet also covers products starting with IC300 instead of HE800 or HE-. Additional technical information is found in the following supplements: HE200WCM910 (MAN0782)

More information

Astra-R Kit Wireless Alarm System Operation Manual

Astra-R Kit Wireless Alarm System Operation Manual Astra-R Kit Wireless Alarm System Operation Manual This operation manual describes principles of functioning, proper use, maintenance and service for the wireless alarm system Astra- R Kit (Figure 1).

More information

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL Introduction Thank you for choosing ZRP-100 Z-Wave Repeater product! ZRP-100 is a Z-Wave repeater with best RF performance to repeat Z-Wave

More information

RN-41-SM. Class 1 Bluetooth Socket Module. Features. Applications. Description. Block Diagram. rn-41sm-ds 9/9/2009

RN-41-SM. Class 1 Bluetooth Socket Module. Features. Applications. Description. Block Diagram.   rn-41sm-ds 9/9/2009 RN-41-SM www.rovingnetworks.com rn-41sm-ds 9/9/2009 Class 1 Bluetooth Socket Module Features Socket module 3/5V DC TTL I/O Fully qualified Bluetooth 2.1/2.0/1.2/1.1 module Bluetooth v2.0+edr support Low

More information

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips remote control openers security at your fingertips G703 residential gate opener for sliding gates Installation instructions Toll free helpline Please have your serial number and model name available before

More information

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit Service Instructions The Conductor Controls Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit Table of Contents General Section Page Safety Instructions.. 4 Introduction 5 Inspection and Long-Term

More information

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!!

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!! Contents Page Number Range Problems 2 TRC Commander Transmitter 3 TRC Commander Receiver 4 SideKick Transmitter 5 SideKick Receiver 5 Permanent Receiver Card for Rainbird ESP MC, SAT, PAR, & Maxicom Controllers

More information

RELAY G10S PILOT S GUIDE B Yamaha Guitar Group, Inc. All rights reserved.

RELAY G10S PILOT S GUIDE B Yamaha Guitar Group, Inc. All rights reserved. RELAY G10S PILOT S GUIDE 40-00-0402 - B www.line6.com/manuals 2018 Yamaha Guitar Group, Inc. All rights reserved. System Overview Wireless freedom for your pedalboard Best in class sound quality provided

More information

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz 900 MHz FHSS DNT90/Ethernet Gateway Optional 128-Bit AES Encryption Point-to-point, Point-to-multipoint or Store and Forward Operation 158 mw EIRP 900 MHz Transmitter Power 10/100Base-T Auto-sensing Ethernet

More information

Ambient Weather F007PF 8-Channel Wireless Water Thermometer User Manual

Ambient Weather F007PF 8-Channel Wireless Water Thermometer User Manual Ambient Weather F007PF 8-Channel Wireless Water Thermometer User Manual Table of Contents 1 Introduction... 2 2 Getting Started... 2 Parts List... 2 2.1 Water Thermometer Sensor Set Up... 2 3 Glossary

More information

SMART TOILET CONTROL

SMART TOILET CONTROL WARNING: WARNING: SMART TOILET CONTROL Installation and Maintenance Instructions Part# STC THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION.

More information

S-COR. FIGURE 1 Wiring Diagram NOTE: To reset S-COR to factory settings, press and! hold < and > buttons upon power up. INSTALLATION INSTRUCTIONS

S-COR. FIGURE 1 Wiring Diagram NOTE: To reset S-COR to factory settings, press and! hold < and > buttons upon power up. INSTALLATION INSTRUCTIONS Section 1 General Description The ClearPath Spectrum Wireless System is comprised of two devices; a Coordinator () that functions in a similar role as traditional wireless system receivers, and a Transceiver

More information

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12 Version 1.3 July 2002 TABLE OF CONTENTS 1.0 DESCRIPTION... 1 2.0 AMPLIFIER FEATURES... 1 3.0 DEVICE SPECIFICATIONS... 2 4.0 INDOOR AMPLIFIER KIT... 3 5.0 INSTALLATION AND CABLING INSTRUCTIONS... 4 6.0

More information

Sensors. EasySense. Fixture-Mount for Basic Grouping

Sensors. EasySense. Fixture-Mount for Basic Grouping Sensors EasySense Fixture-Mount for Basic Grouping The Philips EasySense fixture-mount sensor is the ideal solution for per-fixture control of new light fixtures. It combines occupancy sensing, daylight

More information

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit

More information

This document is intended for Lighting Control Systems professionals

This document is intended for Lighting Control Systems professionals This document is intended for Lighting Control Systems professionals This document applies to fixture with factory installed SVPD1, SVPD2, SVPD3 integrated sensors. Table of contents Quick Reference Guide...

More information

FinishLynx Interface. Includes: Power requirements: 9 VDC Power Adapter (included) Size: Approximately 5 x 3 x 2 Approximate weight: 5.57oz.

FinishLynx Interface. Includes: Power requirements: 9 VDC Power Adapter (included) Size: Approximately 5 x 3 x 2 Approximate weight: 5.57oz. FinishLynx Interface Includes: FinishLynx Wired Interface Or 1 ea. FinishLynx Wireless Interface & MPCX Receiver FinishLynx CAPTION PLATE SET w/layout Diagram Power requirements: 9 VDC Power Adapter (included)

More information

X80 Activator. User's Manual. Version 1.1.

X80 Activator. User's Manual. Version 1.1. X80 Activator User's Manual Version 1.1 www.buckeyecam.com Table of Contents 1. Warnings... 3 2. Overview... 4 3. Getting Started... 5 4. Using the Activate Button... 7 5. Wiring... 8 6. Specifications...

More information

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A. D Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1 Maintenance Manual Printed in U.S.A. This page intentionally left blank 13 PARTS LIST 12 PARTS LIST LBI-31807 11 PARTS LIST 10 SCHEMATIC

More information

WS-9006U Wireless Temperature Station

WS-9006U Wireless Temperature Station WS-9006U Wireless Temperature Station Instruction Manual RF reception indicator Outdoor Temperature Indoor Temperature Time Outdoor Temperature Sensor TX43U MIN/MAX/+ Button CF / SET Button FEATURES: Four

More information

DNT24MCA DNT24MPA. Low Cost 2.4 GHz FHSS Transceiver Modules with I/O. DNT24MCA/MPA Absolute Maximum Ratings. DNT24MCA/MPA Electrical Characteristics

DNT24MCA DNT24MPA. Low Cost 2.4 GHz FHSS Transceiver Modules with I/O. DNT24MCA/MPA Absolute Maximum Ratings. DNT24MCA/MPA Electrical Characteristics - 2.4 GHz Frequency Hopping Spread Spectrum Transceivers - Direct Peer-to-peer Low Latency Communication - Transmitter RF Power Configurable - 10 or 63 mw - Built-in Chip Antenna - 250 kbps RF Data Rate

More information

AW900i. User s Manual. Point-to-point. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

AW900i. User s Manual. Point-to-point. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems Point-to-point Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems Non-line-of-sight :: 900 MHz Thank you for your purchase of the point-to-point wireless Ethernet bridge.

More information

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc, Complete Remote Control System 1 4 Channel Remote Control Systems 12 or 24Vdc Supply AM / FM Remote Receiver Decoder High Security Protocol Easy Learn Tx Encoder Feature Easy Installation via Screw Terminals.

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL FOR RBDA-PCS-1/25W-90-A INDOOR REPEATER TABLE OF CONTENTS PARAGRAPH PAGE NO BDA OVERVIEW 3 BDA BLOCK DIAGRAM DESCRIPTION 3 FCC INFORMATION FOR USER 3 BDA BLOCK DIAGRAM

More information

swarm radio Platform & Interface Description

swarm radio Platform & Interface Description Test Specification Test Procedure for Nanotron Sensor Modules Version Number: 2.10 Author: Thomas Reschke swarm radio Platform & Interface Description 1.0 NA-13-0267-0002-1.0 Document Information Document

More information

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation

More information

DECORATOR COMFORT CONTROL (DCC)

DECORATOR COMFORT CONTROL (DCC) DECORATOR COMFORT CONTROL (DCC) The Decorator Comfort Control (DCC) enables a window treatment to provide shading from the sun automatically and conveniently. The DCC sun sensor continually monitors sun

More information

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

TT W Wireless receiver Inline Switch

TT W Wireless receiver Inline Switch TT403 1000W Wireless receiver Inline Switch Product Description The TT403 is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

WPR400 Wireless Portable Reader

WPR400 Wireless Portable Reader P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents

More information

LC-RF, LC-IR, LC-PC PRODUCT OFFERING. Type. Project LED RGB CONTROLLER SOLUTION GUIDE LC SERIES. Catalog No.

LC-RF, LC-IR, LC-PC PRODUCT OFFERING. Type. Project LED RGB CONTROLLER SOLUTION GUIDE LC SERIES. Catalog No. PRODUCT OFFERING Control Image Radio Frequency - Controlled with remote up to 30 ft away - Controller can be hidden - Max 1 controller per location LC-RF-300 Allows user to control RGB lights from remote

More information

HeLAN Motor Control Board

HeLAN Motor Control Board module components. Figure 1 shows the main component locations for the circuit CAUTION: You must be free of static electricity before handling circuit boards. Wear a grounding strap or touch a bare metal

More information

Sensors. EasySense. Fixture-Mount for Advanced Grouping

Sensors. EasySense. Fixture-Mount for Advanced Grouping Sensors EasySense Fixture-Mount for Advanced Grouping The Philips EasySense fixture-mount sensor is the ideal solution for per-fixture control of new light fixtures. It combines occupancy sensing, daylight

More information

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual Active Transmitter Combiner 8:1 AC 3200-II Instruction manual Contents Contents Important safety instructions... 2 The AC 3200-II active transmitter combiner 8:1... 4 Delivery includes... 4 Connection

More information

SABRETrap Control. Description

SABRETrap Control. Description SABRETrap Control Features Rugged radio remote control One transmitter can control Many receivers Waterproof receiver to IP68 Transmitters available with 1, 3,4 and 8 Switches Supplied ready to operate

More information