Highly Sensitive Tube-Topology Magnetoelectric Magnetic Sensors. A Dissertation Presented. Scott Matthew Gillette

Size: px
Start display at page:

Download "Highly Sensitive Tube-Topology Magnetoelectric Magnetic Sensors. A Dissertation Presented. Scott Matthew Gillette"

Transcription

1 Highly Sensitive Tube-Topology Magnetoelectric Magnetic Sensors A Dissertation Presented by Scott Matthew Gillette to The Department of Electrical and Computer Engineering in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the field of Electrical Engineering Northeastern University Boston, Massachusetts November, 2013

2 Abstract Magnetoelectric (ME) composites have drawn increasing interest in recent years due to advancements in the technology resulting in enhanced ME coupling coefficients, stable roomtemperature operation, sub-nanotesla noise floor, low- and zero-biased operation, and fabrication of compact, miniaturized devices. Now, more than ever, practical use of ME devices in commercial magnetometry applications is feasible, while continued development of numerous other applications, such as voltage-tunable magnetic field generators, voltage-tunable inductors, and magnetically-tunable capacitors, bolster the overall usefulness of ME composites as a valuable technology. This dissertation focuses on development and characterization of tubetopology ME composites as magnetic field sensors. The novel topology is most notable for demonstrating high zero-external-bias sensitivity, low noise floor, low-frequency bandwidth, and self-powered, stable room temperature operation. Numerous characterization studies are included in this work where several devices are analyzed as a function of test-field, DC-bias field, geometry, material choice, and more. The overall conclusions drawn upon these results indicate strongly that the tube-topology ME magnetic field sensor holds promise to compete with existing hall-effect and flux-gate magnetometers. ME composites are at the tipping point of commercialization for use in magnetometry applications and are emerging as a valuable technology for use in numerous creative ways. i

3 Acknowledgements I thank my advisor, Professor Vincent Harris, for giving me the opportunity to work at Northeastern University s Center for Microwave Magnetic Materials and Integrated Circuits for the past four years. He has generously shared his time and knowledge to guide me through a challenging, invaluably rewarding PhD program. Thank you! I thank Prof. Yajie Chen for his extensive help, creative wisdom, and strong perspectives during this time. I thank Dr. Anton Geiler, who has acted as my mentor, for sharing his brilliant expertise on numerous research efforts. While the work performed during these past four years was enjoyable, it was the people with whom I ve worked with that have made it a true pleasure, and for that I extend a great thanks to all of my colleagues at CM3IC. Finally, I thank my friends and family, my parents, my sister, and my beloved wife Stephanie who kept me alive during this time, for all of your support and encouragement. I love you all and am incredibly grateful. Thank you! ii

4 Table of Contents Abstract... i Acknowledgements... ii Table of Contents... iii Table of Figures... v Table of Tables... xi Chapter 1. Introduction Introduction to Dissertation Background and Phenomena of the Magnetoelectric Effect Piezoelectric and Magnetostrictive Materials Strain Coupled Magnetoelectric Composites ME Composites as Magnetic Field Sensors D31 Sensor Type D33 Sensor Type Tube-Topology Sensor Type Operational Modes Chapter 2. Tube-Topology ME Composites as Magnetic Field Sensors Introduction and Motivation Composite Construction Fabrication Instructions Experimental Setup Experimental Setup Version Experimental Setup Version Effects of Intrinsic Magnetostriction on Tube-Topology Magnetoelectric Composites ME Composite Length Study iii

5 Demagnetization Effects Active-Region Effects Galfenol Length Study Iron-Nickel Length Data Test Field Amplitude and Frequency Study Amplitude Study Frequency Study Array Study cm FN ME Composite Highlights D15 Operational Mode Device Experimental Setup Considerations Chapter 3. Conclusion Research Summary Improvements for Future Development Appendix A.1. Experimental Setup 1 Equipment List A.2. Experimental Setup 2 Equipment List A.3. LabView Program A.4. MATLAB Demagnetization Factor Calculator References iv

6 Table of Figures Figure 1: Direct interactions between stress (σ) and strain (ϵ), electric field (E) and polarization (P), and magnetic field (H) and magnetization (M), are illustrated with the red, yellow, and blue arrows, respectively. In a single phase multiferroic magnetoelectric material (green arrows), electric field is directly coupled to magnetic field. In many multiferroic magnetoelectric devices, strain-coupling (black arrows) between magnetostrictive and piezoelectric phases provides the magnetoelectric effect.[4]... 3 Figure 2: Illustration demonstrating ME effect in single-phase multiferroic Cr2O3. Motion of the Cr 3+ ions is observed between states of zero electric field (left), and applied electric field (right), disturbing the ferromagnetic Cr sub-lattice, which demonstrates magnetoelectric coupling.[13]... 5 Figure 3: Three different structural types of ME composite topologies are shown where the green may either represent a piezoelectric or magnetostrictive material and the void volume represents the counterpart. (a) Embedded spheres inside of a volume. (b) Heterostructural stacking is the most common. (c) Pillar arrangement Figure 4: The direct magnetoelectric effect refers to a magnetoelectric system that produces an output voltage response caused by an applied magnetic field Figure 5: The converse magnetoelectric effect refers to a system that produces a magnetization within the magnetostrictive component, resulting in a change to the fringe field, caused by an applied electric field (voltage) Figure 6: Piezoelectric strain response as a function of applied electric field for two different aspect ratios of thin film Lead Zirconate Titanate (PZT) substrates. ε33 indicates that both applied electric field and measured strain were in the Z-axis of the substrate.[36] Figure 7: Piezoelectric materials exhibit coupling between strain and polarization such that strain is generated due to an applied electric field, and similarly, that a voltage will be generated in response to an applied strain v

7 Figure 8: Magnetization and strain for TERFENOL-D as a function of applied magnetic field. The derivative of magnetostriction is plotted with the dashed line.[32] Figure 9: Magnetostrictive materials exhibit coupling between magnetization and strain such that strain is generated in response to an applied magnetic field, and similarly, magnetization of the sample occurs under applied strain Figure 10: a) A commercial piezoelectric microphone guitar pickup fabricated by Artec.[40] b) A commercial piezoelectric precision actuator capable of micron resolution manufactured by Physik Instruments.[41] Figure 11: a) A magnetostrictive audio transducer that allows a surface, such as a table, wall, or window, to act as a speaker. This commercially available device uses the magnetostrictive material TERFENOL-D and is fabricated by FeONIC.[42] b) A commercial magnetostrictive linear position sensor, with micron resolution, produced by MTS Sensors.[43] Figure 12: a) A PZT/Metglas multiferroic magnetostrictive composite, mounted to a Mylar slab, fabricated by Bolin Hu at Northeastern University's CM3IC. This image shows the leads attached for measuring the magnetoelectric effect. b) Cross-sectional view of the PZT/Metglas composite fabricated through pulse laser deposition of a PZT target onto a polished Metglas sheet. Not drawn to scale Figure 13: a-d) SEM surface images of PZT grown under different oxygen pressures. e) SEM cross-section image of 300mTorr growth sample. f) Zoomed view of (e) showing distinct layers and boundaries of PZT, platinum, and Metglas Figure 14: a) A Metglas /PZT/Metglas multiferroic magnetostrictive laminate provided by Carmine Carosella, mounted to a Teflon slab. The dime is provided for size reference. b) Cross-sectional view of the Metglas /PZT/Metglas heterostructure. The Metglas strains under an applied magnetic field causing a strain-induced electric field transverse to the PZT. Not drawn to scale Figure 15: Magnetoelectric multilayer fabricated through epitaxial growth of NiFe2O4 (NFO) on BaTiO3 (BTO) on a SrTiO3 (STO) substrate. The interfaces are emphasized using horizontal lines.[46] Figure 16: ME coupling coefficient of a heterostructural Metglas /polyvinylidene-flouride magnetoelectric laminate composite magnetic field sensor Figure 17: Metglas /PZT/Metglas laminated heterostructural composite, provided by Carmine Carosella, held by tweezers to enable resonance bending modes during testing. Length, height, and thickness dimensions are indicated Figure 18: Metglas /Poled-PZT/Metglas laminated heterostructural composite with interdigitated electrodes, provided by Dwight Viehland. Length, height, and thickness (at two locations along the length) dimensions are indicated vi

8 Figure 19: Metglas /Poled-PZT/Metglas laminated heterostructural composite with interdigitated electrodes, provided by Dwight Viehland. Length, height, and thickness (at two locations along the length) dimensions are indicated Figure 20: D31 and D33 mode operation of piezoelectric PZT. For the D31 mode, a longitudinally applied strain results in a transversely generated voltage response. For the D33 mode, a longitudinally applied strain results in a longitudinally generated voltage response. Directions 3 and 1 are denoted on the vertical and horizontal axis, respectively Figure 21: Example of an interdigitated electrode geometry. Interdigitated electrodes are typically used in ME laminates where the piezoelectric phase is to be operated in a D33 mode, as exemplified by D33 Sensor Figure 22: Diagram of tube-topology device operational nomenclature. Mechanical action is always applied in the x (1) direct. Devices investigated in this research operate in either a d31 or d51 mode Figure 23: a) Carbolite STF 15/180 tube furnace. b) Fisher Scientific Isotemp HV hot plate. c) Stanford Research Systems PS310 high voltage dc power supply. d) Weller WES51 soldering iron station. e) Omega HH501DK thermometer with Type-K thermocouple Figure 24: Fabrication diagram of the ME tube-topology composite. The fixed end is where devices are clamped during testing Figure 25: a) Dual-Helmholtz coil design with D31 Sensor centered inside. b) Dual-Helmholtz coil inside of the double-layer Gauss chamber. Tube-topology ME composite is positioned inside of Helmholtz coil for characterization Figure 26: DUT mounting apparatus consisting of plastic tweezers held by a table-top vice-grip. All components are non-magnetic. a) Top-down view. b) Rotated side-view Figure 27: Schematic of single Helmholtz coil design made from PVC tube (not drawn to scale). Radius, R, and distance, D, are made to be equal in order to satisfy Helmholtz design. Dual-Helmholtz design requires use of two PVC tubes that can be nested Figure 28: Simulated field distribution pattern from dual-nesting Helmholtz coil design Figure 29: Modeled field uniformity of the fabricated dual-nesting Helmholtz coil Figure 30: Block diagram of experimental setup Figure 31: DC calibration curve characterizing relationship between SR830 auxiliary voltage output and the magnetic field generated by the Sorensen DC power supply Figure 32: Solenoid fabricated for use in experimental setup version Figure 33: Schematic of solenoid coil design made from PVC tube (not drawn to scale) vii

9 Figure 34: Simulated field distribution pattern for solenoid coil design Figure 35: Modeled field uniformity of the fabricated solenoid coil Figure 36: Block diagram of experimental setup version Figure 37: DC magnetic bias field calibration curve for solenoid coil Figure 38: Diagram of DUT placement within solenoid. Solenoid is surrounded by a triple-layer Gauss chamber. Drawing is not to scale Figure 39: a) Vishay P3 strain meter. b) Omega strain gauge attached to magnetostrictive wire Figure 40: Magnetostriction as a function of applied magnetic field for three types of wire Figure 41: Derivative of magnetostriction as a function applied field, dλ/dh Figure 42: a) VSM data comparing M vs. H for FG (WB21), FC, and FN wire samples. b) Zoomed plot showing low-h magnetization response Figure 43: Sensitivity is plotted as a function of swept bipolar applied magnetic bias field. Sensor FN exhibits highest sensitivity under low- (<20 Oe) and zero-biased conditions while sensor FG exhibits higher sensitivity at bias fields > 20 Oe Figure 44: The peak sensitivity curve is captured while sweeping from max applied magnetic field to zero. Magnetic field is applied starting at -50 Oe and swept towards zero. This curve displays peak device performance Figure 45: Magnetic spectral density plots for optimally biased (a, on left) and zero-biased (b, on right) conditions are displayed. All devices exhibit noise floor in the nanotesla range at low frequency. A 25 Hz, 1 moe (100 nt), magnetic test field was applied during measurement Figure 46: Coordinate system used for calculating demagnetization factors. A cylinder, positioned axially along the z axis, is shown, however dimensions a, b, and c may be applied to most shapes Figure 47: Demagnetization factors calculated for the magnetostrictive wire shape. Insert shows zoomed in region where Nx, Ny, and Nz, are equal at a length of 0.1 cm Figure 48: Normalized effects of Nz demagnetization factor in the wire as a function of length. Insert shows absolute demagnetization factor for Nz Figure 49: a) Magnetostriction as a function of magnetic field applied from 0 Oe, to +500 Oe, to -500 Oe, and then to +500 Oe. Hysteresis effects are observed. b) Notional magnetostrictive data generated by averaging data points at equal bias, per wire Figure 50: dλ/dh as a function of applied magnetic field for different lengths of iron-nickel wire viii

10 Figure 51: Drift in the magnetostrictive measurement as a function of time. Drift is presented as a percentage-change, relative to the full scale range of collected data Figure 52: ME coupling coefficient as a function of applied magnetic bias for Metglas /PZT/Metglas heterostructural laminates for different N, where N denotes the number of Metglas layers Figure 53: Sensitivity vs. applied magnetic bias field for various lengths of tube-topology ME composites made using Galfenol wire batch WB Figure 54: Sensitivity vs. length for varying DC magnetic bias applied to composites fabricated using the Galfenol wire batch WB Figure 55: Sensitivity vs. applied magnetic bias field for various lengths of tube-topology ME composites made using Galfenol wire batch WB Figure 56: Sensitivity vs. length for varying magnetic DC bias applied to ME composites made using Galfenol wire batch WB14. The cracked 5cm sensor is excluded Figure 57: Vibrating-sample magnetometer (VSM) data comparing Galfenol wire batches WB14, (a) left, and WB21, (b) right Figure 58: (a) VSM comparison at low applied field for WB14 and WB21 Galfenol wire samples. WB14 is shown to be magnetically softer than WB21. The effect of this is shown in (b) which demonstrates sensitivity vs. applied magnetic field for 5cm long devices Figure 59: Sensitivity as a function of magnetic bias field for 8 cm and 5 cm lengths of ME composites fabricated using magnetostrictive iron-nickel wire Figure 60: (a) Sensitivity as a function of magnetic bias for different amplitudes of test field. (b) Sensitivity vs. test field amplitude under zero external magnetic bias Figure 61: Sensitivity vs. test field amplitude for 5 and 7.5 cm WB21 devices. The test field was fixed at 25 Hz. A fixed 20 Oe DC magnetic bias was applied during testing Figure 62: Sensitivity as a function of frequency for 7.5 cm and 5 cm WB21 device. A 20 Oe bias field was applied constantly. The test field was maintained at 0.25 Oe RMS Figure 63: Sensitivity as a function of frequency for the 8 cm FN device. Test field amplitudes of 0.1 and 1 Oe RMS were measured at zero bias and 1 Oe DC bias conditions Figure 64: Sensitivity vs. frequency for the 5 cm FN device. Test field amplitudes of 0.1 and 1 Oe RMS were measured at zero bias and 10 Oe DC bias conditions Figure 65: Diagram showing three identically-manufactured 5 cm FN tube sensors connected in series Figure 66: Sensitivity measurements for individual and series configurations for three 5cm FN devices measured at 100 Hz, 0.25 Oe RMS under a 7.5 Oe magnetic bias field ix

11 Figure 67: Sensitivity vs. magnetic bias field for the 8cm FN device. A 25 Hz, 10 moe test field served as reference Figure 68: Single-polarity plot of sensitivity vs. magnetic bias field to emphasize effect of hysteresis on low-bias sensitivity Figure 69: Magnetic spectral density plot from 1 Hz thru 30 Hz demonstrating low-frequency pseudo-noise floor response of the 8cm FN wire with applied bias of 7.5 Oe Figure 70: Zero-bias frequency response from Hz thru 5 KHz of the 8cm FN sensor. The test field was set at 1 Oe RMS and frequency was swept. Log-plot (inset) is shown to emphasize low-frequency response Figure 71: Nomenclature for describing directions in a PZT crystal for a 3D system on the left and the XY plane on the right. The shear-y axis (direction 5) is shown by the polarization vector in the XY plane Figure 72: D15 mode device fabricated using iron-nickel magnetostrictive wire and PZT tube. a) Diagram showing the double helical electrode structure that was fabricated, (b), using 20 um gold wires tightly wrapped around the tube exterior Figure 73: Sensitivity vs. magnetic bias field for the D15 sensor. A 1.8 Oe RMS test field alternating at 400 Hz was used for reference Figure 74: Magnetic spectral density plot for the D15 sensor. A 400 Hz, 0.01 Oe RMS magnetic field is applied for reference Figure 75: Sensitivity vs. elapsed time for 5 days. Periodic background environmental noise is apparent during day. 10mV/Oe variations observed during daytime, 4 mv/oe at night Figure 76: Modeled and measured noise for the shorted-input case. Contributing factors for modeled noise are shown along with total noise (sum) Figure 77: Modeled open-input state noise contributing factors and total, consisting of sum. Measured data is overlaid Figure 78: 8 cm FN wire voltage output noise floor is shown to be limited by the electronics noise floor, with exception to a few spurious environmental noise peaks Figure 79: Schematic of charge amplifier circuit (left) used to fabricate battery powered charge amplifier used in noise floor measurements (right) Figure 80: Low frequency noise floor measurements for zero-biased and 7.5 Oe biased 8cm FN sensor with and without charge amplifier x

12 Table of Tables Table 1: Piezoelectric Material Properties Table 2: Magnetostrictive Material Properties Table 3: Overview and Comparison of Device Performance xi

13 Chapter 1. Introduction 1.1. Introduction to Dissertation The research presented in this dissertation focuses on the development of novel tube-like topological magnetoelectric (ME) composites and strongly focuses on examining variations in the design towards the realization of ME magnetic field sensing devices. The recently developed tube-topology, sometimes referred to as quasi-one-dimensional, but herein referred to as tubetopology, is unique from any previously existing magnetoelectric composite device topology. Tube-topology ME composites, configured for use as magnetic field sensors, exhibit high sensitivity at zero-external-bias field, low noise floor, and high signal-to-noise ratio (SNR). These devices are self-powered and require no conditioning circuitry. They are also miniature, lightweight, easily fabricated, and exhibit highly directional axial sensitivity which enables better spatial resolution than heterostructural-laminate topology counterparts. The experiments, results, discussions, and insights pertaining to the novel tube-topology ME composite developed at Northeastern University s Center for Microwave Magnetic Materials and Integrated Circuits (CM3IC) are reported within. 1

14 This dissertation consists of three chapters that contain the following information. In Chapter 1, background to the magnetoelectric effect and similar operational phenomena is presented. In addition, discussion on piezoelectric and magnetostrictive materials is provided. Magnetoelectric composites are introduced and examples of devices exhibiting different operational modes are overviewed. Finally, the magnetoelectric tube-topology device is introduced. It is assumed the reader is well acquainted with ferromagnetic and ferroelectric phenomena in materials. In Chapter 2, aspects of the tube-topology ME composite are investigated in a series of studies that examine effects of externally applied magnetic bias, device length, magnetostrictive wire type, frequency and amplitude response, noise analysis, and more. Chapter 3 concludes the dissertation with a general overview of findings, details for future improvements, and closing thoughts Background and Phenomena of the Magnetoelectric Effect The magnetoelectric (ME) effect is the underlying phenomena investigated in this research. The effect was first realized by Pierre Curie in 1894 and later, mathematically theorized by Landau and Dzyaloshinskii between late 1950 s and early 1960 s.[1-3] The ME effect is defined as the ability to induce magnetization through an applied electric field and/or to induce polarization through an applied magnetic field.[4-6] This effect can be enabled due to direct coupling of electric field with magnetization, magnetic field with polarization, and polarization with magnetization, or indirectly via strain. Each relationship is illustrated in Figure 1. 2

15 Figure 1: Direct interactions between stress (σ) and strain (ϵ), electric field (E) and polarization (P), and magnetic field (H) and magnetization (M), are illustrated with the red, yellow, and blue arrows, respectively. In a single phase multiferroic magnetoelectric material (green arrows), electric field is directly coupled to magnetic field. In many multiferroic magnetoelectric devices, strain-coupling (black arrows) between magnetostrictive and piezoelectric phases provides the magnetoelectric effect.[4] The term magnetoelectric effect may be used to describe the phenomena; however, it is now conventional and more accurate to describe the flow of energy in ME devices with the terminology direct magnetoelectric effect or converse magnetoelectric effect.[5, 7] The direct magnetoelectric effect (DME) describes magnetic-field-induced polarization, and similarly magnetic-field-induced voltage, as shown in equation (1.1). (1.1) The converse magnetoelectric effect (CME) describes electric field induced magnetization as shown in equation (1.2). 3

16 (1.2) The magnetoelectric coupling coefficient, α, defined in units of, is the physical term which serves as the conventional figure of merit for quantifying the ability of a device to transduce energy between magnetic and electric domains. The magnetoelectric voltage coefficient, defined in units of, is used to describe the sensitivity of engineered devices and is more practical for comparing the performance between different types of ME devices and for evaluating ME devices for specific applications.[5, 8] The ME effect manifests in two distinct types of structures; single-phase multiferroics, and composites of magnetostrictive and piezoelectric materials. The effect occurs in single-phase multiferroic materials that exhibit direct coupling between electrical polarization and magnetic polarization, where the term multiferroic denotes such a material that exhibits two or more combinations of ferroic orders, such as ferroelectric and ferromagnetic ordering. The first single-phase multiferroic ME material was discovered over half a century ago, Cr2O3, is shown in Figure 2. Numerous other single-phase materials have been discovered since then. Despite discovery of several single-phase multiferroic magnetoelectric materials, efforts towards realizing them for practical use have been largely unsuccessful.[5, 6, 8-10] The problem with single-phase multiferroics is that the ME coupling magnitude is relatively weak at room temperature. At lower temperatures ME coupling coefficients increase but not significantly enough to justify maintaining a low temperature environment for applications. Research efforts continue in the field of single-phase multiferroics and recently significantly a higher ME coupling coefficient for a Z-type hexaferrite compound, Sr3Co2Fe24O41, has been reported thus maintaining the relevancy of single-phase ME materials.[11, 12] 4

17 Figure 2: Illustration demonstrating ME effect in single-phase multiferroic Cr 2 O 3. Motion of the Cr 3+ ions is observed between states of zero electric field (left), and applied electric field (right), disturbing the ferromagnetic Cr sub-lattice, which demonstrates magnetoelectric coupling.[13] The ME effect may also be enabled by fabricating bulk, micro, and more recently, nanoscale combinations of piezoelectric and magnetostrictive materials together in a mechanically elastic manner where electric and magnetic energy transfer is mediated through strain, as illustrated by the black arrows in Figure 1.[4-8, 14-25] ME composites are unique from singlephase multiferroics in the sense that composite materials may be chosen based on bulk material properties, which, depending on scale, remain relatively unchanged when formed into composites. 5

18 ME composites have been the most significantly researched method for generating the ME effect due to ability to predict behavior based on constituent performance prior to composite fabrication. Strain-coupled composites consisting of a bulk single-phase magnetostrictive material with a bulk single-phase piezoelectric material have demonstrated direct magnetoelectric coupling coefficients on the order of 100, which is several orders of magnitude higher than reported coefficients of single phase multiferroic magnetoelectrics.[5] ME composites are also relatively easy to fabricate and numerous geometries have already been studied such as those shown in Figure 3. For this reason, strain-coupled ME composites, exhibiting large ME coupling coefficients at room temperature hold great potential for the development of applications. 6

19 Figure 3: Three different structural types of ME composite topologies are shown where the green may either represent a piezoelectric or magnetostrictive material and the void volume represents the counterpart. (a) Embedded spheres inside of a volume. (b) Heterostructural stacking is the most common. (c) Pillar arrangement. In composites of magnetostrictive and piezoelectric materials, the direct magnetoelectric effect is the result of the product of the respective magneto-mechanical and inverse 7

20 electromechanical strain interaction as described in equation (1.3) and the interaction is illustrated in Figure 4. (1.3) Figure 4: The direct magnetoelectric effect refers to a magnetoelectric system that produces an output voltage response caused by an applied magnetic field. The converse magnetoelectric effect is the product of the electromechanical and inverse magneto-mechanical strain interaction as described in equation (1.4) and the interaction is illustrated in Figure 5.[5] 8

21 1.4 Figure 5: The converse magnetoelectric effect refers to a system that produces a magnetization within the magnetostrictive component, resulting in a change to the fringe field, caused by an applied electric field (voltage). Equations (1.3) and (1.4) indicate that strain transfer is responsible for transducing magnetic energy to electric energy for the DME effect and vice versa for the CME effect. For instance, if a magnetoelectric composite operating in a DME mode is exposed to a magnetic field, represented by the numerator in the first term of (1.3), the magnetostrictive phase will 9

22 elastically deform due in response to the magnetic field, represented by the denominator of the first term in (1.3). The magnetostrictively induced strain will transfer to the piezoelectric phase causing a mechanical deformation, represented by the numerator of the second term in (1.3), and generate a separation of charge resulting in polarization, as represented by the denominator of the second term in (1.3). The reverse flow of energy happens for the CME effect as shown in equation (1.4). The research presented in this dissertation pertains to a unique topology of composites that obtain the magnetoelectric effect through strain coupling between mechanically bonded bulk magnetostrictive and piezoelectric materials. For related information on single phase multiferroic magnetoelectric materials that exhibit direct coupling, the reader is encouraged to review the literature as no additional discussion on this subject is provided in this dissertation.[26-29] 1.3. Piezoelectric and Magnetostrictive Materials Ferroelectrics and ferromagnetics are distinct classes of materials under which the manipulation of polarization and magnetization occurs through the application of electric and magnetic fields, respectively. Certain types of ferroelectric and ferromagnetic materials exhibit physical deformation under the influence of applied electric and magnetic fields, respectively. This property is known as piezoelectricity in ferroelectric materials and magnetostriction in ferromagnetic materials. The atomic lattice spacing of piezoelectric and magnetostrictive materials is strongly coupled to the materials state of polarization and magnetization, 10

23 respectively, allowing for motion to occur via applied fields.[30-35] Although this effect is minute on the atomic level, strain generation in bulk samples is greatly useful for engineered structures. These fundamental material properties are ultimately responsible for generation of the magnetoelectric effect in composites. Atomic lattice coupling with polarization and magnetization also exists in the forms of electrostriction and piezomagnetism; however, these similar phenomena are not discussed in this dissertation. Piezoelectricity is defined as the ability of a material to exhibit coupling between polarization and strain, therefore enabling a coupling between strain and applied electric field. A piezoelectric material will undergo bulk dimensional deformation correlating to an applied electric field as demonstrated by the butterfly-shaped piezoelectric response curve of thin film lead zircon titanate (PZT) in Figure 6 and as illustrated by the electro-mechanical interaction in Figure 7.[36] Figure 6: Piezoelectric strain response as a function of applied electric field for two different aspect ratios of thin film Lead Zirconate Titanate (PZT) substrates. ε33 indicates that both applied electric field and measured strain were in the Z-axis of the substrate.[36] 11

24 Figure 7: Piezoelectric materials exhibit coupling between strain and polarization such that strain is generated due to an applied electric field, and similarly, that a voltage will be generated in response to an applied strain. The general constitutive equations for a piezoelectric material, (1.5) and (1.6), mathematically describe strain and electric displacement, respectively. (1.5) (1.6) The strain,, is defined as the axial change in length divided by original length. The magnetic flux density is denoted by D and E is the applied electric field. Variables, and represent the material s remnant strain and polarization, respectively. The elastic compliance tensor, the piezoelectric tensor, and the dielectric permittivity tensor are defined by the material s properties.[37, 38] 12

25 Magnetostriction describes ferromagnetic materials with the ability to exhibit coupling between magnetization and strain, thus providing a coupling of strain to applied magnetic field. A magnetostrictive material will strain in response to an applied magnetic field, as demonstrated by the magnetostriction curve in Figure 8 and as illustrated by the magneto-mechanical interaction in Figure 9. Figure 8: Magnetization and strain for TERFENOL-D as a function of applied magnetic field. The derivative of magnetostriction is plotted with the dashed line.[32] 13

26 Figure 9: Magnetostrictive materials exhibit coupling between magnetization and strain such that strain is generated in response to an applied magnetic field, and similarly, magnetization of the sample occurs under applied strain. The general constitutive equations for a magnetostrictive material, (1.7) and (1.8), mathematically describe strain and magnetization, respectively.[39] (1.7) (1.8) Here, strain equals the axial change in length divided by length. The compliance tensor is denoted by. The applied stress T is in units of force per unit area. The 14

27 magnetostrictive strain constant is d. The permeability tensor is denoted by. H is the applied magnetic field and B is the magnetic flux density. The strain coupling in both piezoelectric and magnetostrictive materials operates in a reverse manner such that an applied strain will generate net polarization or magnetization, respectively. The ability to manipulate the dimensions of a piezoelectric material by an applied electric field and a magnetostrictive material by an applied magnetic field, or to generate respective electric and magnetic fields by applying strain, has proven useful in numerous applications. Piezoelectric materials are currently used in commercial devices such as instrument microphone pickups or precision electrostatic actuators as shown in Figure 10. Magnetostrictive materials may be found in commercial devices such as audio transducers and linear position sensors as shown in Figure 11. a b Figure 10: a) A commercial piezoelectric microphone guitar pickup fabricated by Artec.[40] b) A commercial piezoelectric precision actuator capable of micron resolution manufactured by Physik Instruments.[41] 15

28 a b Figure 11: a) A magnetostrictive audio transducer that allows a surface, such as a table, wall, or window, to act as a speaker. This commercially available device uses the magnetostrictive material TERFENOL-D and is fabricated by FeONIC.[42] b) A commercial magnetostrictive linear position sensor, with micron resolution, produced by MTS Sensors.[43] 1.4. Strain Coupled Magnetoelectric Composites Optimal strain coupling requires intimate contact between the magnetostrictive and piezoelectric materials that is typically achieved through direct deposition, gluing (also known as lamination or epoxying), or epitaxial growth fabrication techniques as shown by the examples in Figure 12, Figure 14, and Figure 15, respectively. 16

29 Figure 12: a) A PZT/Metglas multiferroic magnetostrictive composite, mounted to a Mylar slab, fabricated by Bolin Hu at Northeastern University's CM3IC. This image shows the leads attached for measuring the magnetoelectric effect. b) Cross-sectional view of the PZT/Metglas composite fabricated through pulse laser deposition of a PZT target onto a polished Metglas sheet. Not drawn to scale. Direct deposition magnetoelectric composite devices exhibit an atomically distinct yet direct mechanically bonded interface between piezoelectric and magnetostrictive phases that enables excellent strain coupling. These composites are typically made using chemical vapor deposition or pulsed laser deposition of a magnetostrictive phase onto a piezoelectric phase (or vice-versa) and exhibit a thin-film-on-substrate topology. In some composite combinations, buffer layers are used to improve growth conditions while maintaining excellent strain transfer. Buffer layers of gold and platinum were investigated in a recent study at CM3IC determining that use of platinum, shown in Figure 13, acted best as a seed layer for PZT growth and as a diffusion barrier. [44, 45] 17

30 Figure 13: a-d) SEM surface images of PZT grown under different oxygen pressures. e) SEM crosssection image of 300mTorr growth sample. f) Zoomed view of (e) showing distinct layers and boundaries of PZT, platinum, and Metglas. 18

31 Figure 14: a) A Metglas /PZT/Metglas multiferroic magnetostrictive laminate provided by Carmine Carosella, mounted to a Teflon slab. The dime is provided for size reference. b) Cross-sectional view of the Metglas /PZT/Metglas heterostructure. The Metglas strains under an applied magnetic field causing a strain-induced electric field transverse to the PZT. Not drawn to scale. Epoxied ME composites consist of two or more magnetostrictive and piezoelectric phases bonded together using an adhesive that enables strain coupling. The adhesive plays an important role in transferring strain between bulk materials and its mechanical properties must be considered. In addition, certain glued topologies such as the one in Figure 14, require that the adhesive is conductive, allowing the Metglas to serve also as electrodes for collecting charge generated across the PZT. Magnetoelectric laminate composites are abundant in literature due to readily accessible, inexpensive, and large variety of materials to choose from. Additionally, such composites require minimal materials processing and are therefore easily fabricated. The tubetopology ME composites are categorized as this type due to use of a sintered epoxy that serves as binding agent. 19

32 Figure 15: Magnetoelectric multilayer fabricated through epitaxial growth of NiFe 2 O 4 (NFO) on BaTiO 3 (BTO) on a SrTiO 3 (STO) substrate. The interfaces are emphasized using horizontal lines.[46] A ME composite fabricated using epitaxial growth techniques exhibits atomic lattice matching of magnetostrictive and piezoelectric phases. This intimate crystallographic interface between phases results in favorable, and typically the most efficient, strain coupling. Epitaxially-grown magnetoelectrics are not as common as laminates due to the complex fabrication process which requires that each phase exhibits similarly sized crystal lattices. This requirement also limits the combinations of compatible magnetostrictive and piezoelectric materials. 20

33 Strain coupled ME composites can be described using the following constituent equations, (1.9), (1.10), and (1.11), that relate ME and piezoelectric phases through elastic interaction.[5] (1.9) (1.10) (1.11) For equations (1.9), (1.10), and (1.11), σ, D, and B represent stress, electric displacement, and magnetic induction, respectively. S, E, and H are the strain, electric field, and magnetic field, respectively. Tensors c, e, q, ε, α, and μ, are the stiffness, piezoelectric coefficient, piezomagnetic coefficient, dielectric constant, magnetoelectric coefficient, and permeability, respectively, are determined by the choice of materials used in the composite. The superscript T denotes the transpose of the tensor.[5] Properties of several common piezoelectric and magnetostrictive materials used in magnetoelectric composites are shown in Table 1, and Table 2, respectively.[8] The piezoelectric material PZT has been widely investigated for use in ME composites of various topologies. PZT exhibits a relatively high piezoelectric constant, resulting in higher polarization per input strain than BTO and PVDF. In addition, PZT is abundant, inexpensive, and available in several unique geometries. Magnetostrictive materials such as iron-nickel alloys, 21

34 Galfenol, and iron-cobalt-vanadium alloys exhibit relatively low-to-mid saturation magnetostriction values compared to materials like Terfenol-D. However, unlike Terfenol-D, which has a saturation magnetostriction of 1400 parts per million at bias fields on the order of 2500 Oe, these alloys exhibit useful magnetostriction under significantly smaller applied bias magnetic field magnitudes. An important step towards implementing ME composites in commercial applications is to minimize or eliminate magnetic bias field requirements. By developing ME composites that require little-to-no magnetic bias, enormous cost, volume, and weight savings may be realized. In this dissertation, PZT is chosen as the piezoelectric materials while several magnetostrictive materials that operate under low-bias field are examined. Table 1: Piezoelectric Material Properties. BaTiO3 PZT-5 PZT-4 PZNPT PMNPT PVDF d31(pc/n) N/A d33(pc/n) N/A ε Tc(ºC) ρ(g/cm 3 ) Qm N/A N/A N/A 4 k

35 For Table 1, d31 and d33 represent piezoelectric constants, ε is the permittivity, Tc is the Curie temperature, ρ is density, Qm is the mechanical quality factor, and k33 is the electromechanical coupling factor. Table 2: Magnetostrictive Material Properties. NiFe2O4 Terfenol-D Fe-Ga Metglas 2605 λ(ppm) μ >40000 k33 N/A 0.44 N/A 0.37 Qm N/A N/A N/A 1000 ρ(g/cm 3 ) R(Ω-m) 1e6 5.8e-7 6e-7 1.3e-6 Tc(ºC) 535 N/A N/A 395 For Table 2, λ is the saturation magnetostriction, μ is the permeability, k33 is the electromechanical coupling factor, Qm is the mechanical quality factor, ρ is density, R is resistivity, and Tc is the Curie temperature.[8] Of the three methods for fabricating strain-coupled ME devices, laminate composites exhibit the largest sensitivity. Recently, Dr. Dwight Viehland, from the Department of Material Science and Engineering at Virginia Polytechnic Institute, has demonstrated one of the highest 23

36 magnetoelectric coupling coefficient in a device fabricated by laminating together thin layers of Metglas (25 microns) to polyvinylidene-flouride (28 microns).[47] This device exhibits an offresonance ME sensitivity coefficient of approximately 7 V/cm-Oe corresponding to a 1 KHz AC input magnetic field and an 8 Oe magnetic bias field as shown in Figure 16 (a), left. In Figure 16 b), right, an on-resonance ME sensitivity coefficient of 310 V/cm-Oe, corresponding to an electro-magneto-mechanical mode stimulation frequency of approximately 50 KHz, is shown for an applied static magnetic field of 8 Oe. Figure 16: ME coupling coefficient of a heterostructural Metglas /polyvinylidene-flouride magnetoelectric laminate composite magnetic field sensor. Although no commercial applications utilizing the magnetoelectric effect yet exist, several proposed applications utilizing the relatively large magnetoelectric effect associated with ME laminate composites are currently in research and development phases. These applications 24

37 include the development of tunable microwave devices, voltage-controlled inductors, voltagecontrolled magnetic field generators, magnetically-tunable capacitors, voltage-tunable transformers, and foremost, magnetic field sensors.[5] Presented in this dissertation is an investigation of the use of magnetoelectric composites as magnetic field sensors ME Composites as Magnetic Field Sensors Strain-coupled ME composites that exhibit large coupling coefficients have emerged as promising candidates for the development of highly-sensitive magnetic field sensors in recent years.[8] Key advantages of this technology include operation at room temperature, low cost, and simple fabrication requirements. In addition, steadily increasing magnetoelectric coefficient values potentially enable these devices to target highly-sensitive magnetometer markets that include optically pumped cesium vapor magnetometers, spin-exchange relaxation-free (SERF) atomic magnetometers, and superconducting quantum interference devices (SQUID).[48] As previously described, ME composite magnetic field sensors rely on a stress-mediated coupling between magnetostrictive and piezoelectric phases in order to produce an output voltage in response to an applied magnetic field. Magnetostrictive phases that have been utilized in the construction of ME sensors include Terfenol-D, Metglas, and Galfenol intermetallic alloys, as referenced in Table 2, whereas the piezoelectric phase is typically lead zirconate titanate (PZT) or lead magnesium niobate - lead titanate (PMN-PT), as referenced in Table 1. The magnetoelectric effect is obtained through bonding the aforementioned materials together such that under the influence of an applied magnetic field, the magnetic phase becomes longitudinally or transversely magnetized, inducing strain on the piezoelectric phase causing longitudinal or 25

38 transverse poling. Depending on material geometry, the terms longitudinally and transversely are described using axially or radially, as is the case with cylindrically-shaped devices, to describe direction of applied fields or induced strain D31 Sensor Type Three types of ME composite magnetic field sensors are overviewed in the following to demonstrate the most common operational modes in comparison to the novel topology invented at NU. The first ME composite type, shown in Figure 17, is a laminated composite tri-layer heterostructure consisting of a piezoelectric PZT film bonded between two magnetostrictive Metglas ribbons in a Metglas /PZT/Metglas configuration, provided by Carmine Carosella. The Metglas /PZT/Metglas topology allows for the Metglas to act as both magnetostrictive phase and electrodes where charge can accumulate as the PZT phase undergoes strain. Leads were attached to each Metglas ribbon allowing for voltage measurements. The dimensions of this magnetoelectric laminate were measured to be 28.3 mm long by 2.0 mm wide by 0.2 mm thick accounting for a total volume of mm 3. Metglas ribbons are manufactured to be 1 mil thick, equal to millimeters. Therefore the PZT film including the thickness of the lamination adhesive is calculated to be approximately mm thick (149.2 microns). This device is categorized as a longitudinally magnetized, transversely poled magnetoelectric magnetic field sensor and is designed to exhibit peak performance for sensing magnetic fields that interact parallel to its length. This device will be referenced in the following work and referred to herein as the D31 Sensor. 26

39 Figure 17: Metglas /PZT/Metglas laminated heterostructural composite, provided by Carmine Carosella, held by tweezers to enable resonance bending modes during testing. Length, height, and thickness dimensions are indicated D33 Sensor Type The second ME composite type, shown in Figure 18, is a laminated tri-layer heterostructure which consists of a poled PZT film that is bonded between two magnetostrictive Metglas ribbons in a Metglas /Poled-PZT/Metglas topology. Instead of utilizing the Metglas phase as an electrode, this sensor exhibits internal patterned interdigitated electrodes in contact with the poled-pzt film separated by a distance of approximately 1mm. This ME magnetic field sensor is categorized as a longitudinally magnetized, longitudinally poled device and is designed to exhibit peak performance for sensing magnetic fields that interact parallel to its length. The dimensions of this magnetoelectric laminate were measured to be 80.4 mm long by 10.4 mm wide and exhibited a thickness of 0.4mm where PZT was sandwiched between Metglas, and a thickness of 0.2 mm in the absence of a PZT layer at either end. The total volume of this device, accounting for the capton-tape edges, is approximately 410 mm 3. This indicates that four layers of Metglas (two layers laminated together per side of PZT) were used 27

40 in total. The approximate thickness of PZT, including lamination adhesive, is calculated to be 0.2 mm. The Metglas layers were purposefully constructed to exhibit a length longer than that of the PZT phase in order to reduce clamping which ultimately maximizes the ME coefficient by straining the PZT in a more uniform manner. Extensive optimization regarding number of Metglas layers, Metglas length, and additional factors have been investigated.[49] This device was generously provided by Dwight Viehland s Materials Science group at Virginia Polytechnic Institute. This device will be referenced in the following work and referred to herein as the D33 Sensor. Figure 18: Metglas /Poled-PZT/Metglas laminated heterostructural composite with interdigitated electrodes, provided by Dwight Viehland. Length, height, and thickness (at two locations along the length) dimensions are indicated Tube-Topology Sensor Type The third ME composite type, shown in Figure 19, is an epoxy-bound cylindrical structure consisting of a poled PZT tube surrounding a metallic magnetostrictive wire. It is this 28

41 tube-topology design that serves as the main research topic in this work. The metallic magnetostrictive wire also serves as the inner conductor, collecting charge generated at the inner diameter of the PZT tube, to which it is bonded with using a silver conductive epoxy. Silver paint applied to the outer surface of the PZT tube acts as the outer conductor. The PZT tube is 1mm in outer diameter and exhibits a ~0.8 mm inner diameter and tube lengths from 1.5 cm thru 8 cm have been manufactured and tested. The magnetostrictive wire exhibits an outer diameter of 0.6mm and is typically cut to a length ~2 cm longer than the PZT tube. During fabrication the tube is centered on the wire such that a small extension of wire protrudes on either side of the PZT tube. Presumably this prevents mechanical clamping at the ends and provides greater strain transfer, resulting in higher ME coefficient, in a similar fashion as the Virginia Tech device. This ME magnetic field sensor is categorized as an axially-magnetized, radially-poled device and is designed exhibit peak performance for sensing magnetic fields vectors that interact parallel to the length of the cylinder. The dimensions of the tube-topology composites tested in this work are of varying length but all exhibit a fixed outer diameter of 1mm at the tube, and 0.6mm at the wire. Lengths have been fabricated from 1.5cm up to 8cm accounting for total device volumes between 47 mm 3 thru 274 mm 3. Reference to this sensor type in the following work will include specifics on sensor length and magnetostrictive wire type. 29

42 Figure 19: Metglas /Poled-PZT/Metglas laminated heterostructural composite with interdigitated electrodes, provided by Dwight Viehland. Length, height, and thickness (at two locations along the length) dimensions are indicated Operational Modes The first two types of ME sensors, shown in Figure 17 and Figure 18 as D31 Sensor and D33 Sensor respectively, are constructed of similar materials in the same layered laminate topology; however, each sensor operates in a fundamentally different manner due to the directionally dependent method of harvesting the piezoelectrically generated voltage response of strained PZT. It is observed in Table 1 that the D33 piezoelectric coefficient is much greater than the D31 coefficient for PZT of similar types. A diagram demonstrating the difference between utilizing PZT in a D31 mode and a D33 mode is shown in Figure 20.[50] 30

43 Figure 20: D31 and D33 mode operation of piezoelectric PZT. For the D31 mode, a longitudinally applied strain results in a transversely generated voltage response. For the D33 mode, a longitudinally applied strain results in a longitudinally generated voltage response. Directions 3 and 1 are denoted on the vertical and horizontal axis, respectively. D31 Sensor was fabricated to utilize the PZT in a D31 mode where a longitudinally applied strain, coupled from magnetostrictively induced strain in the Metglas, results in a transversely generated voltage response. Conveniently, use of a D31 mode enables D31 Sensor to utilize the Metglas as electrodes on either side of the PZT film. Although the piezoelectric coefficient is lower for ME sensors utilizing the D31 mode, the complexity of sensor construction is greatly reduced. D33 Sensor was fabricated to utilize the PZT in a D33 mode where a longitudinally applied strain, coupled from magnetostrictively induced strain in the Metglas, results in a 31

44 longitudinally generated voltage response. In order to detect this voltage response an interdigitated pair of electrodes, demonstrated by the geometry shown in Figure 21, was placed longitudinally on the PZT, underneath the Metglas. Leads were then attached to exposed portions of the interdigitated pair of electrodes for voltage measurements. By designing a ME magnetic field senor to utilize the D33 sensing mode, the device benefits from a higher piezoelectric coefficient but increases the complexity of sensor construction. + Vout - Figure 21: Example of an interdigitated electrode geometry. Interdigitated electrodes are typically used in ME laminates where the piezoelectric phase is to be operated in a D33 mode, as exemplified by D33 Sensor. The following chapter details the figures of merit of various builds of the tube-topology ME sensor in a magnetic field sensing application. The majority of tube topology devices fabricated operate in a d31 mode as illustrated by the diagram in Figure 22, however discussion of a novel device designed to operate in a d51 mode is also presented.[51] In Chapter 2, several sensors are characterized using the conventional method of biasing magnetoelectric magnetic field sensors with an applied static (DC) magnetic field. Numerous characterizations are presented including; sensitivity vs. DC magnetic bias field, magnetostriction vs. magnetic bias, 32

45 magnetization vs. applied magnetic field, sensitivity vs. length, sensitivity vs. test field amplitude, frequency response, and noise floor. Figure 22: Diagram of tube-topology device operational nomenclature. Mechanical action is always applied in the x (1) direct. Devices investigated in this research operate in either a d 31 or d 51 mode. 33

46 Chapter 2. Tube-Topology ME Composites as Magnetic Field Sensors 2.1. Introduction and Motivation Magnetoelectric composites have great potential for numerous applications such as magnetic storage, automotive sensors, navigation systems, non-destructive material testing, security systems, structural stability, medical sensors, military instruments, and most commonly, magnetic field sensors.[52, 53] The superconducting quantum interference device (SQUID) is reputed to be the most sensitive magnetic field sensors, achieving a magnetic field resolution on the order of several femtotesla. The sensor itself has a power consumption of several watts and its operation is based on flux quantization and the Josephson effect, both of which are observable only in the presence of superconductivity. As such, it operates below the superconducting transitions temperature at cryogenic temperatures, requiring a significant amount of power, and suffers from acute sensitivity to electromagnetic interference. Older, more traditional types of magnetic field sensors are based on the Hall and magnetoresistive effect, which also require external power supply. As such, a self-powered magnetic field sensor that transduces magnetic energy to electrical signals would be of great value and utility. Such sensors can be realized 34

47 through the magnetoelectric (ME) effect, which is observed in single-phase multiferroics (MF), and piezoelectric-magnetostrictive composites.[14, 54] As previously mentioned, in material composites, electric polarization occurs in response to an applied magnetic field and similarly, magnetization occurs in response to an applied voltage. As a result, a transducer capable of large magnetoelectric coupling coefficients, α=de/dh, may provide a potential device route towards development of highly sensitive magnetic field sensors, tunable microwave filters, tunable transformers, voltage-controlled inductors, magnetically-tunable capacitors, and voltage-driven magnetic field generators.[55-59] Magnetic field sensors are needed for the detection of low frequency (10-2 thru 10 3 Hz) minute magnetic field variations (~10-12 T) in applications ranging from non-invasive neurological interfaces for quadriplegics to magneto-encephalography and magnetic anomaly detectors.[22] Furthermore, in order to be deployable, emerging field sensor technologies need to operate at room temperature, be electronically passive, and small in volume. No known sensor meets all of these stringent requirements. However, composite heterostructures consisting of bonded piezoelectric and magnetostrictive components offer large ME effects at room temperature allowing for high performance of field sensors.[5, 60] Since magnetostrictive materials typically operate optimally under DC magnetic bias field conditions, ME field sensors typically require a DC bias field to maximize sensitivity. Disadvantageously, generation of magnetic bias fields increases power consumption, volume, and costs. Therefore, reducing, or even eliminating the need for bias fields, has become of great interest for its potential to provide new pathways to miniature, lightweight, low power, room-temperature, highly-sensitive magnetic field sensing technologies. In this chapter, the development of ME tube-topology composites for use as magnetic field sensors is detailed. 35

48 2.2. Composite Construction Fabrication of the tube-topology ME composite took place at Northeastern University s CM3IC facility. The composite consists of five basic materials; PZT tubes, magnetostrictive wire, conductive epoxy, silver paint, and copper magnet wire. The PZT tubes were sourced from Smart Materials Corporation in geometries of 15 cm long, 1 mm outer diameter, and 0.8mm inner diameter.[61] The magnetostrictive wires were sourced from the Baotou Research Institute of Rare Earths in Baotou, Inner Mongolia, China. Three different types of magnetostrictive wires were experimented with; Galfenol (two separate batches), iron-cobalt-vanadium alloy, and ironnickel alloy. The conductive epoxy or conductive composition was sourced from ESL EUROPE and is part number 9910-C. The silver paint, called PELCO Conductive Silver Paint, was sourced from Ted Pella and has part number Copper magnet wire, with gauge of 32 AWG, was sourced from the lab and used as leads for connecting to devices. Fabrication of these devices requires use of the following equipment at NU s CM3IC laboratory: furnace capable of 535 ºC and an argon atmosphere, high-voltage DC power supply capable of applying 200VDC, soldering iron, hot plate capable of 100 ºC, and a thermocouple with temperature gauge. The specific instruments used are as follows. A Carbolite STF 15/180 tube furnace was used for the sintering process. A Fisher Scientific Isotemp HV hot plate was used to apply heat during the poling process. A Stanford Research Systems PS310 high voltage dc power supply was used to apply DC voltage during the poling process. An Omega HH501DK Type-K thermometer with thermocouple was used to monitor temperature during the poling process. A Weller WES51 soldering iron station was used for attaching copper 36

49 leads. A Fluke 87V digital multimeter was used to test conductivity. Pictures of each of these instruments are shown below in Figure 23. Figure 23: a) Carbolite STF 15/180 tube furnace. b) Fisher Scientific Isotemp HV hot plate. c) Stanford Research Systems PS310 high voltage dc power supply. d) Weller WES51 soldering iron station. e) Omega HH501DK thermometer with Type-K thermocouple Fabrication Instructions The following procedure outlines the precise method for fabricating these devices and is written as a step-by-step instruction set with considerations included. 37

50 1) Cut PZT tube to length. Due to PZT being a ceramic material, it is not recommended to simply snap the tube as it will break unevenly and unpredictably. Use of either a diamond saw or diamond scribe is recommended. 2) Cut magnetostrictive wire to length. The wire is cut longer than the PZT tube to reduce strain clamping at ends of the tube and to provide access to inner electrode. 3) Using sand paper, or similar abrasive, lightly sand the exterior of the magnetostrictive wire. This step is designed to remove any oxide coating in order to provide better adhesion to the epoxy and ultimately better strain transfer. Do not over-sand as decreasing the diameter of the wire will reduce strain generation. 4) Ensure the wire fits inside the PZT tube. Some of the PZT tubes were noticed to exhibit non-uniform inner diameters which prevented insertion of the wire. 5) Coat the magnetostrictive wire with silver conductive epoxy compound and insert into PZT tube. It is recommended that this step is repeated numerous times until the inner surface of the tube is entirely coated with the epoxy. The tube is slightly translucent and visually changes once coated. This step is critical because strain is transferred between active materials via the epoxy. 6) Clean the edges of the tube such that no conductive epoxy overlaps onto the outer diameter of the tube. If not properly cleaned, the outer diameter surface may become electrically shorted to the inner diameter surface (wire) once the silver paint is applied. 7) Sinter the device at 535 degrees Celsius for 35 minutes in an atmosphere of argon. A ramp rate of + 7 ºC/min was used to ramp from room temp to 535 ºC. The sample 38

51 was allowed to cool back to RT naturally. Argon atmosphere is used to prevent oxidation. 8) Apply silver paint to the outer diameter of PZT tube. Be sure the silver paint does not create an electrical short between the outer diameter of the tube and the magnetostrictive wire. This layer will cause strain clamping and reduce output response. Therefore a thin, uniform layer is preferred. Allow at least 20 minutes to dry. 9) Solder a copper lead onto the magnetostrictive wire. Attach a second copper lead onto the silver paint. A combination of soldering and silver paint may be used to ensure good conductivity between copper lead and silver painted surface. Use lowest temperature soldering as possible as the PZT tube may crack due to thermal shock. 10) Test conductivity between lead attached to magnetostrictive wire and lead attached to silver paint to ensure proper connection. 11) Test conductivity between leads to ensure they are not shorted. The DC resistance measurement between inner and outer electrodes (wire and silver paint on tube, respectively) should be greater than 10 megaohms. If this is not the case, check for areas where silver paint or conductive epoxy may be in close proximity to one another. Otherwise check the PZT tube for cracks. A small hairline crack in the tube may act as a conductive path. Conduction between electrodes will reduce the output voltage response of the device and therefore should be minimized. 12) Connect the lead attached to the wire to the positive (+) pole of the high voltage DC power supply and the lead attached to the silver paint on the tube to the negative (-) pole. 39

52 13) Place the device on the hot plate and heat the device to 100 ºC. Monitor the temperature. Optional use of a heat blanket is recommended to maintain uniform temperature across device. 14) Once heated to 100 ºC, apply DC voltage starting at 0 V up to 200 V in increments of 10 V while waiting at least 5 seconds between each increment. This step polarizes the PZT tube which enhances the ME coupling coefficient. The increment-and-wait method was adopted after initial samples fractured under the shock of applying 200VDC directly from zero, without ramping up the field. 15) Allow the device to polarize at 100 ºC, 200 VDC for 30 minutes. 16) After 30 minutes, turn off the hot plate while maintaining the 200 VDC. 17) Once the hot plate reaches room temperature, which can be measured with the theromocouple, reduce the applied field from 200 VDC to 0 VDC in increments of 10 V while again waiting at least 5 seconds between each increment. 18) Composite fabrication is now complete. The leaded magnetoelectric device is ready for use. No further processing is necessary. Several varieties of ME composites were fabricated into the structure shown in Figure 24, each according to the same fabrication method. Clearly, numerous studies can be done on the fabrication technique in order to optimize factors such as polarization temperature, poling voltage, sintering procedure, epoxy type, outer electrode type, and more. However, none of these are included in this dissertation because they are believed to offer minimal improvements in performance as opposed to characterizing effects of different magnetostrictive wires and device 40

53 length. Such manufacturing improvements may be investigated once optimal materials and configuration are identified. Figure 24: Fabrication diagram of the ME tube-topology composite. The fixed end is where devices are clamped during testing Experimental Setup In simplest form, the sensitivity of a ME composite magnetic field sensor may be characterized by the ratio of the magnitude of an applied magnetic field to the generated output voltage of the device and such a measurement is relatively simple. However, like most devices, these composites are non-linear, frequency-sensitive, directionally-dependent, and sensitive to environmental conditions. Therefore, significant consideration has gone into the experimental setup to obtain the most accurate results within the capability of the CM3IC laboratory. The most 41

54 common method, as demonstrated in the literature, for characterizing ME magnetic field sensors is to apply a magnetic test field of known frequency and amplitude and measure the voltage output response as a function of swept amplitude of a superimposed DC magnetic field. The data collected in this type of measurement reveals the nature of ME composite sensitivity as a function of applied DC magnetic bias field for a fixed input test magnetic field. The reason this data type is most common is that it is an efficient way of collecting two important characteristics of a ME composite sensor simultaneously; absolute sensitivity, and sensitivity vs. bias H-field. Absolute sensitivity measurements are most useful for comparing device-to-device performance while sensitivity vs. bias H-field measurements are useful for understanding how to optimize an individual sensor s performance. As such, an experimental setup which can collect the output voltage response both spectrally and at specific frequency as a function of applied magnetic field was developed. Two versions of the setup were developed throughout the timeframe of these experiments. Both versions are described in the following Experimental Setup Version 1 Experimental setup version 1 consists of a dual-helmholtz coil design, capable of generating uniform magnetic fields with only 10% variation over a length of 6 cm. The dual- Helmholtz coil was positioned inside of a dual-layered Gauss chamber in order to isolate the device under test (DUT) from external and environmental noise sources as shown in Figure

55 Figure 25: a) Dual-Helmholtz coil design with D31 Sensor centered inside. b) Dual-Helmholtz coil inside of the double-layer Gauss chamber. Tube-topology ME composite is positioned inside of Helmholtz coil for characterization. Figure 26: DUT mounting apparatus consisting of plastic tweezers held by a table-top vice-grip. All components are non-magnetic. a) Top-down view. b) Rotated side-view. 43

56 The coil covered in black tape, shown in (a) of Figure 25, was made using 200 turns of 26 AWG wire on each winding side of the Helmholtz coil. The coil with exposed amber colored wire was made using 400 turns of 32 AWG wire on each winding side. These coils were made using PVC tubing, a milling machine, and copper magnet wire according to the cross-section schematic in Figure 27, and were designed to nest inside one another. A model of the dualnesting Helmholtz coil s magnetic field distribution was designed using FEMM and is shown in Figure 28 and the field distribution along its central axis is plotted in Figure 29. The design demonstrates approximately 10% error in uniformity over a length of 6 cm, and quickly drops off to just over 30% error in uniformity over a length of 8 cm, which is sufficient for testing devices up to 8 cm long. Figure 27: Schematic of single Helmholtz coil design made from PVC tube (not drawn to scale). Radius, R, and distance, D, are made to be equal in order to satisfy Helmholtz design. Dual-Helmholtz design requires use of two PVC tubes that can be nested. 44

57 Figure 28: Simulated field distribution pattern from dual-nesting Helmholtz coil design. Figure 29: Modeled field uniformity of the fabricated dual-nesting Helmholtz coil. 45

58 The Helmholtz coil design was chosen as the magnetic field generation platform due to its ability to generate relatively uniform fields as opposed to use of permanent magnets. A dual- Helmholtz coil was pursued in experimental setup 1 in order to generate an overall applied magnetic field consisting of an alternating magnetic test field superimposed on a static magnetic bias field. The Helmholtz equation (2.1) calculates magnetic flux density along the central axis through each coil as a function of permeability, number of turns, current, and coil radius. (2.1) Clearly, magnetic field magnitude is controlled in these experiments by current (I) as the number of turns and radius of each coil is fixed, and the medium for the field, air, is also fixed. In these experiments the innermost Helmholtz coil was used to generate the static, or DC, bias field and the outermost coil used to generate the alternating, or AC, magnetic test field. The dual-helmholtz coil was positioned inside a double-layer Gauss chamber which was used to shield the test volume from external magnetic noise sourced. In addition the Gauss chamber was electrically grounded, enabling it to act as a partial Faraday cage to reduce effects of electronic noise in the environment. This testing platform was the foundation of experimental setup 1. A full list of equipment used in this may be found in the Appendix. A block diagram of the setup is shown in Figure

59 Figure 30: Block diagram of experimental setup 1. The bias field coil was driven using a Sorensen DCR 80-12B DC power supply which was controlled digitally by the auxiliary voltage output from a Stanford Research Systems SR380 lock-in amplifier. This allowed for precise, repeatable control of the DC output current enabling DC magnetic field control that was significantly more accurate than by use of the Sorensen s analog knobs. Configuration of this setup was achieved using the following steps. 1) Configure the Sorensen DCR 80-12B strapping for signal programming voltage mode: a. Remove all strapping from current configuration. b. Connect nodes 7 to 8. c. Connect node 1 to + Output. d. Connect node 2 to Output. 47

60 e. On Front Panel, connect + Output to Ground. f. Set Current knobs fully clockwise. 2) Configure SR830 Aux Out 1 to provide voltage programming of the DCR 80-12B: a. Press Aux Out and set to VDC. b. Connect Aux Out 1 + Voltage signal to node 3 on Sorensen DCR. c. Connect Aux Out 1 Ground to node 1 on Sorensen DCR. 3) Connect the Sorensen DCR 80-12B DC output to desired load. A calibration curve, shown in Figure 31, was created to relate the auxiliary voltage out of the SR830 to magnetic field magnitude. The test field coil was driven by the source output on a Stanford Research Systems SR770 and experiment-dependent calibration curves were generated as necessary. Figure 31: DC calibration curve characterizing relationship between SR830 auxiliary voltage output and the magnetic field generated by the Sorensen DC power supply. 48

61 Prior to testing, each ME sensor was mounted into plastic tweezers as shown in Figure 26, and suspended by a table top vice grip fabricated from aluminum and plastic. Supporting each sensor on the end using a clamp is theorized to promote the generation of bending modes, resulting in higher sensitivity, and to reduce mechanical damping effects associated with platform-mounted methods. However, no study was performed to analyze the different sensor mounting methods due to the scope of this work. For consistency, all sensors were mounted in an identical manner during testing and positioned in the center, along the axis, of the Helmholtz coils. Copper leads from the ME sensor under test were connected directly miniature clip leads terminated on a BNC cable attached the input channel A of the SR770 spectrum analyzer. The SR770 was configured to collect data using the following parameters: 1) Setup the SR770 using the following steps: a. Power on. b. Set desired frequency scale. c. Set Window to BMH. d. Set Measure to PSD. e. Set Display to Log Mag. f. Set Units to Volts RMS. g. Set Input to A. h. Set Grounding to Ground. i. Set Coupling to AC. j. Set Trigger to Continuous. k. Set Source to Sine. 49

62 l. Configure source to generate desired magnetic test field. m. Press Auto Scale. n. Set Auto-Ranging On. o. Set Averaging On. p. Set Number Averages to q. Set Average Type to RMS. r. Set Average Mode to Linear. 2) Connect the SR770 source out to load. The SR770 configuration was saved to a floppy disk for backup and this configuration was used for all subsequent measurements in the experimental setup version 1. This experimental setup was capable of generating static magnetic field magnitudes from 0 to +/-50 Oe and alternating magnetic field amplitudes, at frequencies between 1 to 400 Hz, of to 0.5 Oe RMS Experimental Setup Version 2 Experimental setup version 2 consists of a solenoid coil design, capable of generating uniform magnetic fields over a length of 12 cm; nearly double that of the Helmholtz design. The solenoid coil, shown in Figure 32a, was positioned inside of a tri-layered Gauss chamber in this setup as shown in Figure 32b. 50

63 Figure 32: Solenoid fabricated for use in experimental setup version 2. The solenoid consists of 480 turns of 24 AWG wire. This coil was manufactured onto a PVC tube, however no machining was necessary. Instead, double-sided foam tape was used to create the raised barriers which contain the coil windings. A small notch was cut into the center of the tube to fit a transverse hall probe for characterization as shown in the fabrication schematic in Figure 33. Prior to fabrication, a model of the solenoid coil s magnetic field distribution was simulated in FEMM and is shown in Figure 34. The field distribution along its central axis is plotted in Figure 35. The design demonstrates approximately 10% error in uniformity over a length of 10 cm, 20% error in uniformity over a length of 12.5 cm, and then quickly drops off to just over 30% error in uniformity over a length of 14.5 cm, which is more uniform than the previous Helmholtz design in experimental setup 1. 51

64 Figure 33: Schematic of solenoid coil design made from PVC tube (not drawn to scale). Figure 34: Simulated field distribution pattern for solenoid coil design. 52

65 Figure 35: Modeled field uniformity of the fabricated solenoid coil. The solenoid coil design was chosen for the second setup in order to achieve higher uniformity over a longer distance. This design consisted of only a single winding which and, in order to simultaneously pass alternating and direct currents through the single-solenoid coil, a simple solution consisting of a DC block capacitor, was employed. In a sufficiently long solenoid, the induction at the center may be expressed by the solenoid equation (2.2) which calculates magnetic flux density along the central axis through each coil as a function of permeability, number of turns, current, and length. (2.1). Similarly to experimental setup 1, magnetic field magnitude was controlled by current. The solenoid was positioned inside a high-permeability Gauss chamber, consisting of three 53

66 concentric chambers, which were electrically grounded. This testing platform was the foundation of experimental setup 2. A full list of equipment is listed in the Appendix. A block diagram of the setup is shown in Figure 36. Figure 36: Block diagram of experimental setup version 2. The SR770 source output was connected to the solenoid to provide ac test field. The output was DC-blocked by using a large, 2500μF electrolytic capacitor rated for 50V. A digitally programmable AMREL PS30-1.2D DC power supply was directly connected to the solenoid to generate the static bias field. Testing of the superimposed field revealed that this experimental setup successfully generates alternating and static magnetic fields superimposed on one another. A Labview program, shown in the Appendix, was written to enable precise control of the direct current output of the AMREL power supply and to capture data collected by the SR770. This 54

67 setup enabled testing of numerous ME composites to be completed in a very quick, easy, and reproducible manner. A calibration curve, shown in Figure 37, was created to characterize AMREL output current vs. magnetic bias field. Similarly to experimental setup 1, the alternating magnetic test field was driven by the source output on the SR770 and experiment-dependent calibration curves were generated as necessary, which are not included. The ME composite DUT was positioned in the center of the solenoid, along its central axis, during testing as illustrated in Figure 38. Figure 37: DC magnetic bias field calibration curve for solenoid coil. 55

68 Figure 38: Diagram of DUT placement within solenoid. Solenoid is surrounded by a triple-layer Gauss chamber. Drawing is not to scale. DUT mounting, electrical connection to SR770, and configuration of the SR770 was done in the identical way as experimental setup 1, which is detailed in the previous section. This experimental setup was capable of generating static magnetic field magnitudes from 0 to +/-50 Oe and alternating magnetic field amplitudes, at frequencies between 1 to 400 Hz, of to 1 Oe RMS. This concludes description of the experimental testing setups. 56

69 2.4. Effects of Intrinsic Magnetostriction on Tube-Topology Magnetoelectric Composites. Numerous types of topologies, bonding approaches, amplification methods, and sensing techniques have been investigated using ME composites. However, the most important aspects of these devices are the magnetostrictive and piezoelectric materials used in composite fabrication.[22, 48, 62] Typically, piezoelectric materials, exhibiting high piezoelectric constants, such as PZT and PMN-PT, are desirable for generating large strain-induced charge separation. However, in a magnetostrictive material, a large value of saturation magnetostriction does not always make it an optimal material choice. A few factors such as magnetization process, magnetic hysteresis, and magnetic anisotropy should also be considered. Additionally, the slope of the magnetostriction curve (dλ/dh) has a significant influence on ME coupling. The sensitivity of ME magnetic field sensors can be increased by applying an optimal DC magnetic bias field, which is the motivation for creating a testing platform capable of applying superimposed static and alternating magnetic fields. Peak ME sensitivity typically occurs when the magnitude of the external magnetic bias field corresponds with the peak of the derivative of the magnetostriction curve, a maximum in dλ/dh, which can be offset due to factors such as magnetic hysteresis, shape anisotropy, and demagnetization. Depending on the magnetostrictive material, optimal external magnetic bias field magnitude can range from 1 s to 10 s to 1000 s of Oe. For materials requiring high magnetic bias, use of bulky permanent magnets or powerhungry electromagnets are then required, making the device unattractive for use in practical applications. As such, there is increased interest in developing miniature, lightweight, highly- 57

70 sensitive, low-noise ME magnetic field sensors that require little to no magnetic bias for deployment in various magnetometry applications such as UAV-mounted gradiometric arrays. In this study, the magnetostriction curves of three different magnetostrictive wire types were measured, and then, the wires were fabricated into identical geometries of the quazi-onedimensional tube sensor topology. Low-frequency sensitivity and noise floor measurements were collected and are presented. Prior to composite fabrication, magnetostriction data was collected using a Vishay P3 Strain Meter as shown in Figure 39. Samples of wire, approximately 3 cm long, were each bonded to an Omega strain gauge, part number KFG C1-11L1M2R, using Loctite super glue ultra-gel control type. The strain gauge was connected to the Vishay P3 strain meter and the wire was centered inside of the electromagnet of a LakeShore vibrating sample magnetometer such that magnetic field was applied axially. Magnetization of the wire samples was achieved by using the electromagnet on a LakeShore VSM which can apply precise magnetic fields ranging from 0 to +/- 10 KOe. Strain as a function of applied magnetic field was captured for each wire type. Due to the strain gauge being larger in size than the diameter of the wires, a correction factor was applied to the data as shown in equation (2.2). (2.2). Where W is the width of the strain gauge pattern and D is the wire diameter. 58

71 Figure 39: a) Vishay P3 strain meter. b) Omega strain gauge attached to magnetostrictive wire. The corrected strain, as a function of applied magnetic field, is shown in Figure 40 for each wire. Magnetostrictive wires Galfenol, iron-cobalt-vanadium, and iron-nickel, are labeled in Figure 40 as FG, FC, and FN, respectively. The first derivative of strain (slope of the magnetostriction curve) is shown in Figure 41 revealing important features of each wire. Vibrating-sample magnetometry (VSM) data, demonstrating magnetization density as a function of applied magnetic field, is shown in Figure 42, for each wire type. The zoomed in plot in Figure 42b shows that the wires arranged from magnetically softest to hardest are FN, FC, then WB21, which is consistent with the magnetostriction data in the previous plots. The terms magnetically soft or magnetically hard describe the slope of the magnetization vs. H curve. A magnetically soft material has a steeper slope, indicating that it is more easily magnetized under lower applied fields whereas a magnetically hard material has a shallow M vs. H slope, and thus requires larger magnitude applied field to magnetize. 59

72 Figure 40: Magnetostriction as a function of applied magnetic field for three types of wire. Figure 41: Derivative of magnetostriction as a function applied field, dλ/dh. 60

73 Figure 42: a) VSM data comparing M vs. H for FG (WB21), FC, and FN wire samples. b) Zoomed plot showing low-h magnetization response. The FG wire exhibits highest value of saturation magnetostriction, ~57 ppm, under a 500 Oe applied magnetic field. The FC and FN wires exhibit saturation magnetostriction (Ms) values of 11 ppm and 27 ppm, respectively at 500 Oe. Much insight towards optimal wire choice can be gained by analyzing the magnetostriction (λ), and corresponding derivative, curves. For instance, although FG exhibits highest Ms, both FG and FC wires exhibit higher magnetostriction under lower applied bias field. Since it is desirable to reduce and preferably eliminate bias field, wire materials FC and FN would be better choices than FG. Additionally, it is observed in Figure 41 that wire FN exhibits the greatest change in the slope of the magnetostriction curve at nearzero bias and that FC behaves similarly to a lesser extent. It is also observed that wire FG a peak in the dλ/dh curve at approximately 200 Oe, which is out of the range of both experimental setups. The magnetostriction and dλ/dh results suggest that the FN wire is the best material for 61

74 use in a composite and would achieve peak ME sensitivity performance under zero- and lowmagnetic bias field. The FC wire material, when built into and ME composite, should exhibit a sensitivity profile similar to the FN composite, but with reduced sensitivity. The FG composite can be predicted to exhibit highest sensitivity at higher bias fields. The three wire types (Galfenol, iron- cobalt-vanadium, and iron-nickel) were then fabricated into three equal lengths of ME composite magnetic field sensors. Each magnetostrictive wire had a diameter of 0.5 mm and was coupled into a 5 cm long PZT tube, exhibiting an inner diameter of 0.8 mm and outer diameter of 1 mm. Wire lengths of 7 cm were used to reduce strain clamping at opposite ends of the active interface and to provide a contact point for inner electrode. The PZT tube was centered on each wire such that 1 cm of bare wire was exposed at either end of the sensor. Devices were fabricated according to the previously described methodology. In this manner, strain-induced charge separation was detected radially, in a d31 mode, between the outer and inner diameter of the PZT tube. The experimental setup version 2 was used for characterizing the ME composites. An external DC magnetic bias field was superimposed on the test field and was swept through the values of 0, 1, 2, 3, 5, 7.5, 10, 15, 20, 30, and 50 Oe, throughout the following sequence: 0 Oe, +50 Oe, -50 Oe, and +50 Oe. This sweep pattern was used to collect hysteresis behavior of the sensors and to eliminate any measurement error associated with only capturing virgin curve data. Due to relatively low coercivity of each magnetostrictive wire, the sweep pattern effectively erased any effects of magnetic fields applied prior. Copper leads of each sensor were directly connected to the input of a Stanford Research Systems SR770 FFT Analyzer where voltage spectral density (VSD) sweep 62

75 measurements, in units of Vrms/ Hz, were captured from 1 thru 50 Hz. The measurement procedure consisted of capturing sensor response as a function of magnetic bias field using an AMREL PD30-1.2D DC programmable power supply to generate magnetic bias field and then using the SR770 to capture 1000 linearly-averaged VSD measurements at each step. Sensitivity (in V/Oe) and magnetic spectral density (in T/ Hz) were calculated from the raw data and are presented in the following. Sensitivity behavior of the ME tube sensors containing three different magnetostrictive wires are shown in Figure 43. For the first time, hysteretic effects exhibiting butterfly-shaped sensitivity curves were observed in the quasi-one-dimensional tube topology sensors. For sensors FC and FN, sensitivity was observed to initially increase, peak at 20 and 10 Oe respectively, then decrease as magnetic bias field increased from 0 to +50 Oe during virgin curve. For sensor FG, sensitivity was observed to continually increase along with bias field from 0 to +50 Oe. All three sensors exhibited similar behavior as bias field reduced from +50 to 0 Oe in that sensitivity mirrored the shape of the virgin curve but at a higher value, exhibiting hysteresis. 63

76 Figure 43: Sensitivity is plotted as a function of swept bipolar applied magnetic bias field. Sensor FN exhibits highest sensitivity under low- (<20 Oe) and zero-biased conditions while sensor FG exhibits higher sensitivity at bias fields > 20 Oe. Interestingly, as bias field polarity reversed and swept from 0 to -50 Oe, sensitivity minimized for each sensor at -2 Oe, indicating that each magnetostrictive wire has a coercivity of ~2 Oe in this geometrical configuration. More importantly, this indicates that sensors can exhibit an enhanced zero-external-bias sensitivity when a magnetic field is temporarily applied and then removed, enabling the wire to exhibit enhanced magnetostriction under the influence of its own 64

77 internal remnant magnetization. Minimum sensitivity values for FG, FC, and FN sensors were measured at -2 Oe to be 105, 841, and 672 μv/oe, respectively. As bias field swept from -2 to - 50 Oe, sensitivity was shown to increase with field, which is consistent with the magnetic hysteresis loop. Finally, as bias field swept from -50 to +50 Oe, the same trend was exhibited, in reverse. When optimally biased at 50, 15, and 10 Oe, sensors FG, FC, and FN exhibited sensitivity values of 6.88, 2.12, and 5.36 mv/oe, respectively. At zero external-bias, sensors FG, FC, and FN exhibited sensitivity values of 0.843, 1.12, and 3.15 mv/oe, respectively Figure 44: The peak sensitivity curve is captured while sweeping from max applied magnetic field to zero. Magnetic field is applied starting at -50 Oe and swept towards zero. This curve displays peak device performance. 65

78 Peak slope of magnetostriction occurs under very low (<20 Oe) applied magnetic fields for samples FC and FN whereas it occurs at 200 Oe for sample FG. Magnetostriction data is in good agreement with the single-ended sensitivity curves shown in Figure 44, indicating that a maximum in dλ/dh corresponds with peak sensitivity for sensors FC and FN at 15 and 10 Oe, respectively. It also validates the behavior of FG in that sensitivity increases along with applied field, up to 50 Oe, due to the wire undergoing steady increase in dλ/dh from 0 to 50 Oe. The peak sensitivity curves also validate predictions in wire performance based off of magnetostriction data. FC sensor is shown to exhibit a very similar sensitivity profile as the sensor made with FN wire, but with overall reduced ME sensitivity. FG sensor exhibits peak performance under higher bias fields while FN sensor exhibits better performance under low and zero bias. Figure 44 shows peak sensitivity curves of each sensor as a function of external bias field and was captured as magnetic bias magnitude decreased from -50 Oe to 0 Oe. In this way, enhancement to sensitivity was observed relating to hysteresis effects. This effect relates to hysteresis through net alignment of magnetic dipoles in the wire. In a demagnetized state, randomly aligned magnetic dipoles cause a lesser net strain due destructive interference of magnetostriction, resulting in lower strain on the PZT tube, and ultimately a lower voltage response. As the dipole moments become aligned under influence of an externally applied magnetic field, magnetostrictively-induced strain interferes constructively and ultimately results in higher voltage response. Magnetic hysteresis influences not only the degree to which an applied magnetic field further aligns or misaligns dipoles in the wire, but also the field dependence of magnetostriction. This effect is shown in the butterfly shaped curves of Figure 43. Figure 44 emphasizes the peak sensitivity curve, which is captured after magnetic dipole alignment has been established. Most importantly, combination of hysteretic effects and the 66

79 derivative of magnetostriction jointly determine the sensitivity curve of a ME magnetic field sensor. It is postulated that the remnant magnetization of the magnetostrictive wire can be engineered to coincide with the external bias field at which the maximum of the derivative of the magnetostriction curve occurs, to enable optimal sensitivity under zero external magnetic bias. Figure 45: Magnetic spectral density plots for optimally biased (a, on left) and zero-biased (b, on right) conditions are displayed. All devices exhibit noise floor in the nanotesla range at low frequency. A 25 Hz, 1 moe (100 nt), magnetic test field was applied during measurement. Magnetic spectral density response demonstrating the noise floor of each sensor is presented in Figure 45. Magnetic spectral density (MSD) measurements were calculated from measured voltage spectral density (VSD) response. To calculate MSD from VSD the following steps equation was used. MSD = VSD/(Sensitivity*10000). VSD is in units of V/ Hz. Sensitivity is in units of V/Oe, and the factor of converts from Oe to Tesla. Frequency 67

80 sweeps from 1 thru 50 Hz were averaged and captured while applying a 25 Hz, 1 moe test field for reference. Both optimally biased 50 Oe, 15 Oe, and 10 Oe), and zerobias configurations indicate low frequency noise floor in the nanotesla range for all sensors. Sensor FN exhibits the lowest 1-Hz noise floor of all three devices at 2.3 nt/ Hz (1.13 nt accounting for bandwidth) when biased with a 10 Oe H-field. Spurious noise peaks are detected by each sensor and considered to be background electromagnetic noise caused by various external sources such as electronics, fans, building systems, traffic, etc. Sensor FC has a unique, repeatable noise signature at 34 Hz, which does not occur with FN and FG sensors and is considered to be intrinsic to the device, with exact cause still under investigation. In a zerobiased state, FN exhibited a noise floor <10 nt/ Hz from 1 thru 50 Hz, which is lowest of the three devices. The sensitivity and noise floor of a quasi-one-dimensional ME tube sensor is shown to be affected by properties of the magnetostrictive wire. Iron-nickel wire type demonstrated the highest sensitivity, 3.15 mv/oe (315 mv/cm-oe), under no external bias field and also demonstrated the lowest noise floor, <10 nt/ Hz, of all sensors for both bias conditions. Ironcobalt-vanadium wire type exhibits sensitivity of 1.12 mv/oe and Galfenol of mv/oe under no external bias fields. Due to low sensitivity performance of the FC device, no additional analysis is performed on devices made with iron-cobalt-vanadium magnetostrictive wire. Ironnickel and Galfenol wire type ME devices exhibit high sensitivity at both low- and high-bias fields, respectively, suggesting that either variety is suitable for use in opposing environments. High sensitivity in the FN wire type device originates from large changes in magnetostriction under application of low magnetic bias field. These results indicate that use of magnetostrictive wire with large saturation magnetostriction and steep magnetostrictive slope at very low bias 68

81 fields, both attributes of the FN ME composite, may be used to improve zero-bias sensitivity and decrease noise floor ME Composite Length Study The length of the magnetoelectric tube-topology composite was investigated to better understand how geometry affects sensitivity, and seeing as it is the easiest parameter to control, it was examined first. ME composites were fabricated into ME magnetic field sensors of varying length using two different magnetostrictive wire types. Two different batches of Galfenol magnetostrictive wire were available, WB14 and WB21, and both batches were used in this length study along with the iron-nickel (FN) wire type. The length of the ME composite is expected to play a strong role in shaping sensitivity profiles of these devices for three main reasons. First, magnetostriction is dependent on material factors such as magnetization and prestrain. Pre-strain is a strain inflicted on the wire by external sources such as strain caused by the silver conductive epoxy or by the PZT tube after sintering and typically is uncontrollable. Prestrain will change the way the magnetostrictive material responds to magnetization, and may cause changes or shifts in peak dλ/dh, Mz, and influence the way the material responds to a magnetic bias field. Unfortunately no pre-strain study was completed, but it is acknowledged that this effect may be reflected in ME sensitivity measurements. A second factor, magnetization of the wire, is shape dependent. Effective magnetization is influenced by the internal demagnetization field that is dependent upon the geometrical aspect ratio of cross-sectional area to length. As length increases, the demagnetization factor decreases, and as length decreases, 69

82 demagnetization becomes more influential on the effective magnetization of the magnetostrictive wire. The third factor is active region. The length of an ME composite determines the active region, which is defined as the interface area between magnetostrictive and piezoelectric materials. By increasing the active region of the device it is expected that an increase change in charge generation would occur under identical stimulus. The goal of the length study is to understand the influence of length on ME sensitivity and to find a preferential geometrical design Demagnetization Effects The following analysis illustrates the effect of demagnetization as a function of length by relating the demagnetization field contribution to free energy.[63] Gauss s law states that the divergence of magnetic field is zero as shown in equation (2.3).[64] B 0 (2.3). The following terms are defined as: B 4 M (2.4). is the demagnetizing field. (2.5). 4 M is the magnetization vector in CGS units. (2.6). 70

83 Assuming uniform magnetization, which is not precisely accurate but provides a good approximation, the demagnetizing field vector,, may be represented in three dimensions by the following equation. (2.7). Where,,and, are the directionally-dependent demagnetization factors such that, 4 in CGS units. (2.8). For a cylinder placed in the coordinate system, as shown in Figure 46, geometrical dimension a along x-axis, b along y-axis, and c along z-axis, may be used in equations (2.9), (2.10), (2.11), and (2.12) to calculate directionally-dependent demagnetization factors. The sum of demagnetization factors must equal 4π, which serves as way to verify calculations. Figure 46: Coordinate system used for calculating demagnetization factors. A cylinder, positioned axially along the z axis, is shown, however dimensions a, b, and c may be applied to most shapes. 71

84 equations: Directionally-dependent demagnetization factors may be calculated using the following (2.9). 4 / (2.10). 4 / (2.11). 4 (2.12). The demagnetization factors were calculated for a cylinder, representing the magnetostrictive wire, using the MATLAB calculator shown in Appendix A.4 and are shown in Figure 47. Nx and Ny are expectedly equal due both terms representing the radius and exhibit identical behavior such that as length decreases, at lengths < 0.1 cm, the demagnetization factor approaches zero. For lengths >> 0.1 cm, the demagnetization factor approaches 2π. Nz, representing the demagnetization factor along the axis of the wire, which is the same direction magnetic field is applied in during characterization, is shown to be near-zero at lengths greater 72

85 than 4 cm. For completeness, the absolute demagnetization factor value is shown in Figure 48 for lengths of wire used in ME composite fabrication. Figure 47: Demagnetization factors calculated for the magnetostrictive wire shape. Insert shows zoomed in region where N x, N y, and N z, are equal at a length of 0.1 cm. 73

86 Figure 48: Normalized effects of N z demagnetization factor in the wire as a function of length. Insert shows absolute demagnetization factor for N z. For all practical analysis, the demagnetization effects in lengths of magnetostrictive wires used in ME composites, ranging from 2 cm to 10 cm, are negligible. This effect is also seen in Figure 49, which plots magnetostriction as a function of length for the iron-nickel wire. Similarly, and for all practical purposes, the demagnetization factor is not responsible for causing any changes to magnetostriction. It is believed that the primary factor dictating behavior in Figure 49 is physical clamping of the wire due to the strain gauge. As the wire becomes shorter the clamping effect becomes more pronounced. In Figure 50, the derivative of the magnetostriction curves, dλ/dh, for 13 cm, 9 cm, and 5 cm lengths of iron-nickel wire is shown as a function of applied magnetic field. This plot was generated in an attempt to see if the peak of the dλ/dh curve was changing as a function of wire length. Due to the low-resolution experimental setup, which exhibited excessive drift over time, shown in Figure 51, the results are 74

87 unclear. However, ignoring initial and low-field data, it is observed that the peak in the dλ/dh curves shifts from ~65 Oe for the 5 cm wire, to ~50 Oe for the 9 cm wire, to ~ 20 Oe for the 13 cm wire. The importance of this trend will be considered in the sensitivity vs. ME composite length studies presented in the upcoming sections. Figure 49: a) Magnetostriction as a function of magnetic field applied from 0 Oe, to +500 Oe, to -500 Oe, and then to +500 Oe. Hysteresis effects are observed. b) Notional magnetostrictive data generated by averaging data points at equal bias, per wire. 75

88 Figure 50: dλ/dh as a function of applied magnetic field for different lengths of iron-nickel wire. Figure 51: Drift in the magnetostrictive measurement as a function of time. Drift is presented as a percentage-change, relative to the full scale range of collected data. 76

89 Based on this analysis, there does not seem to be any significant effects caused by demagnetization on the lengths of wire used in the ME composites. The quasi-one dimensional geometry maintains an axial demagnetization factor at near-zero Active-Region Effects The active region, as previously described, is the interface layer between piezoelectric and magnetostrictive materials and it is quantified in terms of area. A uniform piezoelectric material undergoing uniform strain will generate a constant separation-of-charge density across its faces. Increasing the amount of surface area where charge is collected is therefore a linear function. According to the equation for the area of the wall of a cylinder, 2 where r is radius and l is the length, it is simple to see that wall area scales linearly with cylinder length. Therefore, the area of the active region scales linearly with ME composite length and it can be postulated that the ME sensitivity does so accordingly. The volume of this structure,, also scales linearly with length. Therefore the active-region-density (active area / total volume) is a constant, 0.7 mm -1. In laminate structures the active-region-density term is simply 1/t, where t is the thickness, and is 5 mm -1 for the D31 Sensor and 2.5 mm -1 for the D33 sensor. It can be generally understood that by reducing the thicknesses of piezoelectric and magnetostrictive materials, a higher active-region-density can be achieved. However, it has been shown, in Figure 52, that optimal thickness does exist for certain composite types, and maximizing the active-region-density is not necessarily preferred.[65] In addition, it is also observed that modifying this ratio can cause shift in optimal magnetic bias field magnitude; an important consideration for designing devices customized for a specific application. Although 77

90 brief, this discussion of the active region is important for understanding optimization methods in fabricating ME composites. Figure 52: ME coupling coefficient as a function of applied magnetic bias for Metglas /PZT/Metglas heterostructural laminates for different N, where N denotes the number of Metglas layers Galfenol Length Study The Galfenol wire batch WB21 was fabricated into four sensors consisting of lengths of 1.5, 2.5, 5, and 7.5 cm. Sensitivity of each sensor was measured using experimental setup 1. For this set of measurements, a 100 Hz, 1 Oe RMS, magnetic test field was applied while the DC bias field was swept over the following steps: 0, 1, 2.5, 5, 7.5, 10, 15, 20, 30, and 50 Oe. 78

91 Sensitivity vs. magnetic bias measurements for four lengths of ME composites fabricated using FG WB21 are shown in Figure 53. Zero-bias sensitivity is observed to increase with length. In addition, it can be envisioned that the optimal magnetic bias field magnitude reduces as sensor length increases. Unfortunately, this behavior is unable to be characterized because of the upper bias field limit of the experimental setup. However, interpretation of the data suggests the 1.5 cm, 2.5 cm and 5 cm length devices have an optimal bias field > 50 Oe. Based on trajectory, it can be inferred that the bias field maximizing sensitivity for the 1.5 cm device is greater than the field requirement of the 5 cm device. Additionally, a reduction in sensitivity is shown for the 7.5 cm device at bias field values greater than 20 Oe, implying that the behavior of each device is that, initially, sensitivity increases with applied bias field, peaks at some optimal bias field magnitude, and then decreases as bias field continually increases. In theory, the slope of the magnetostriction curve, as previously discussed, can explain this behavior. Peak performance is demonstrated by the 7.5 cm device that exhibits a zero-bias sensitivity of mv/oe, and an optimal-bias sensitivity of mv/oe at 20 Oe. 79

92 Figure 53: Sensitivity vs. applied magnetic bias field for various lengths of tube-topology ME composites made using Galfenol wire batch WB21. Sensitivity as a function of length for different bias fields is shown in Figure 54 along with two fit curves. The polynomial fit lines, applied to the 0 Oe and 50 Oe sensitivity curves as in Figure 54 provide excellent agreement between fit and measured data suggesting a third-order polynomial relationship. Coefficients A, B, C, and D were solved on a per-case basis however modeling and defining equations for the coefficients has not yet been completed. (2.13). 80

93 Figure 54: Sensitivity vs. length for varying DC magnetic bias applied to composites fabricated using the Galfenol wire batch WB21. The Galfenol wire batch WB14 was fabricated into three sensors consisting of lengths of 1, 2.5, and 5 cm. Due to slight cracking of the PZT tube on the 5cm device, a second 5cm device was made. Results from both devices are included. Again, sensitivity of each sensor was measured using experimental setup 1, and a stimulus field of 100 Hz, 1 Oe RMS, served as magnetic test field. The same DC magnetic bias steps were applied. Sensitivity vs. magnetic bias measurements for three lengths of ME composites fabricated using FG WB14 are shown in Figure 55. Similar behavior is exhibited with this wire batch to the WB21 batch in that at zerobias, sensitivity increases with length. Again, the same effect showing a reduction to the optimal magnetic field bias magnitude as length increases is observed. For the 5 cm device it is observed that peak biasing occurs at 20 Oe and that sensitivity decreases at higher bias field. Peak performance is demonstrated by the 5 cm device that exhibits a zero-bias sensitivity of

94 mv/oe, and an optimal-bias sensitivity of mv/oe at 20 Oe, making the 5 cm WB14 device comparable to the 7.5 cm WB21 device under optimal bias. Figure 55: Sensitivity vs. applied magnetic bias field for various lengths of tube-topology ME composites made using Galfenol wire batch WB14. Sensitivity as a function of length at different bias fields is shown in Figure 56 along with third order polynomial fit functions applied to the 0 Oe and 50 Oe sensitivity curves. Again the fit function is a close match suggesting the system is governed by the equation in (2.13). 82

95 Figure 56: Sensitivity vs. length for varying magnetic DC bias applied to ME composites made using Galfenol wire batch WB14. The cracked 5cm sensor is excluded. Comparing device performance between Galfenol wire batches provides interesting insight relating to material properties. VSM data, for magnetic field applied parallel and perpendicular to the length of the wire, is shown in Figure 57, for both Galfenol wire batches. WB14 exhibits a saturation magnetization of ~2000 emu/cc whereas WB21 saturates at 1300 emu/cc. In addition, the zoomed-in VSM plot, shown in Figure 58a, shows that WB14 is significantly more magnetically soft, meaning that the slope of the magnetization curve vs. H is steeper, than the WB21 material. 83

96 Figure 57: Vibrating-sample magnetometer (VSM) data comparing Galfenol wire batches WB14, (a) left, and WB21, (b) right. Figure 58: (a) VSM comparison at low applied field for WB14 and WB21 Galfenol wire samples. WB14 is shown to be magnetically softer than WB21. The effect of this is shown in (b) which demonstrates sensitivity vs. applied magnetic field for 5cm long devices. Peak sensitivity for the 5cm WB14 sensor is 12.5 mv/oe, shown in Figure 58b, and occurs at a magnetic bias field of 20 Oe. The 5cm WB21 sensor exhibits a peak sensitivity of 84

97 9.55 mv/oe at 30 Oe. In addition, the entire WB14 curve exhibits higher sensitivity at lower bias fields, except for the 0 Oe and 50 Oe field points, appearing to have shifted towards H = 0. These results imply that it is possible to shift and enhance ME composite sensitivity by engineering the magnetostrictive material. The trend is such that use of a magnetically soft magnetostrictive material will shift the optimal magnetic bias field towards zero, and magnetically harder materials will shift away from zero Iron-Nickel Length Data The 5cm iron-nickel (FN) ME composite demonstrated the highest zero-bias sensitivity, shown in Figure 44, of 3.15 mv/oe, compared to devices made using from other magnetostrictive wire types. In addition, it exhibited a peak sensitivity of 5.26 mv/oe at a bias field of 7.5 Oe. The FN wire effectively resulted in a 62.5% and 75% reduction of optimal magnetic bias field for WB14 and WB21 sensors, respectively. This type of improvement translates to energy savings in an electromagnet-driven application, or weight and volume savings in a permanent magnet-driven application. Accordingly, the largest ME composite fabricated for these experiments was made using an 11cm piece of FN wire and an 8cm PZT tube. Sensitivity of the 8cm FN device is compared with that of the 5cm device in Figure 59 for a 10mOe, 25 Hz magnetic test field. Experimental setup version 2 was used and magnetic bias field was swept from 0 to +50, then -50, and then +50 Oe to generate the butterfly-shaped curve. Note that the hysteretic nature of the magnetostrictive wire works in favor of maintaining high sensitivity as external bias returns to zero. Zero-bias performance significantly increases from 2.84 mv/oe, exhibited by the 5cm device, to 13.1 mv/oe exhibited by the 8 cm device, 85

98 representing a ~360% increase in sensitivity due to a 60% increase in length. Optimal-bias sensitivity increased from 4.7 to 18.1 mv/oe, demonstrating a 285% improvement. Due to its high performance, the 8cm FN composite is further studied in various ways in the following. Figure 59: Sensitivity as a function of magnetic bias field for 8 cm and 5 cm lengths of ME composites fabricated using magnetostrictive iron-nickel wire. 86

99 2.6. Test Field Amplitude and Frequency Study Off-the-shelf components are engineered to operate within a set of amplitude limits for static fields and within a bandwidth for alternating fields. In most cases, the limits are put in place because a device falls into non-linear or unpredictable behavior when operating beyond them and may even self-destruct. As there is always an underlying effort to commercialize new technology, specific limitations to the technology must be identified in order to target applications. As such, characterizing the behavior of the tube-topology ME composites with respect to applied field amplitude and frequency is important. In this section, the sensitivity (mv/oe) is evaluated as a function of magnetic field amplitude and frequency, within the limitations of the experimental setup Amplitude Study Amplitude characterization is performed on these devices to understand trends in sensor behavior and to identify, if any, a linear operational range. Due to magnetic and magnetostrictive saturation, these devices will inherently exhibit non-linear behavior at saturation-onset field amplitudes. In this study a conventional DC magnetic-biasing technique, applied using experimental setup version 1, is employed to characterize the amplitude linearity of tubetopology ME magnetic sensors. This section focuses on measurements of ME sensors constructed with iron-nickel magnetostrictive wire and fabricated to lengths of 5 and 8 cm. A 100 Hz test field was used for reference, which was characterized using a LakeShore 421 Gaussmeter, with amplitude varying 87

100 from 0.1 to 1.2 Oe. Sensitivity response as a function of magnetic bias for varying test field amplitude is shown in Figure 60. It is observed that ME sensitivity increases as magnetic test field decreases from 1.2 to 0.1 Oe. Both sensors present similar trends in sensitivity with bias field, yielding a maximum in sensitivity at a bias field of Oe, which is related to a maximum in the dλ/dh vs. H curve. In contrast, the 8-cm sensor shows sensitivity (22 mv/ Oe) twice that (10.5 mv/oe) of the 5-cm sensor at a bias of 10 Oe for a 100 Hz Hac test field of 0.1 Oe. This length-dependent enhancement in sensitivity is significant and assumed to relate mostly to increased active PZT/wire interface area. It is observed that the zero-bias sensitivity also increases more than 200%, from 8 to 16.5 mv/oe, at 0.1 Oe signal amplitude. Remarkably, these tube-topology ME composite sensors have demonstrated very high sensitivity (6-17 mv/oe) at zero DC bias field with variable 100 Hz test field amplitude of 0.1 to 1.2 Oe rms. There is clearly a linear relationship between sensitivity and signal field for both 5 and 8 cm FN sensors as depicted in Figure 60b. It is observed that the 8 cm device exhibits a slightly steeper slope than the 5 cm device as Hac approaches 0 Oe RMS. This trend suggests that output sensitivity increases with device length while test field amplitude decreases. Therefore, the FN tube sensors have greater potential to work with small sensing signals, which is justified by the linear increase in sensitivity with decreasing sensing field. 88

101 Figure 60: (a) Sensitivity as a function of magnetic bias for different amplitudes of test field. (b) Sensitivity vs. test field amplitude under zero external magnetic bias. Two Galfenol ME composites, 5 cm and 7.5 cm, were characterized as a function of test field amplitude under a fixed 20 Oe bias. A 25 Hz test field was applied and its amplitude swept from 0.1 to 1.2 Oe RMS. Interestingly, the Galfenol devices, shown in Figure 61, exhibit the opposite sensitivity vs. field amplitude trend as the FN devices. Here, sensitivity is shown to increase linearly with magnetic field amplitude. This behavior can be attributed to the WB21 magnetostriction curve that demonstrates a relatively flat, but positively sloped, strain vs. H curve at low applied fields. Presumably, this linear relationship deteriorates at test field amplitude increases due to the nonlinear behavior of magnetostriction. 89

102 Figure 61: Sensitivity vs. test field amplitude for 5 and 7.5 cm WB21 devices. The test field was fixed at 25 Hz. A fixed 20 Oe DC magnetic bias was applied during testing. For practical purposes, discovering that the WB21 and FN composites exhibit linear but opposite trends in sensitivity vs. test field amplitude is an exciting result. This study has revealed that the WB21 wire is preferential for detective larger amplitude fields whereas the FN wire preferably detects lower amplitude fields. Limitations in the test setup prevented characterization at higher field amplitudes where magnetostrictive saturation effects are expected to occur Frequency Study Frequency response is an important characteristic of any sensor that detects alternating fields. The bandwidth of magnetic field sensors is of great importance at low and ultra-low frequencies due to numerous magnetic field signatures of interest that exist in the range of

103 thru 10 3 Hz. Unfortunately, the low-frequency range is plagued by 1/f noise which becomes the dominating signal as the frequency-of-interest approaches 0 Hz. ME composite sensors designed to detect alternating fields usually exhibit wide linear regions on either side of a magneto-electromechanical resonance. The resonance frequency of most ME composites is typically in the range of 10 KHz to 100 KHz, and sometimes higher. The general trend, as demonstrated in the literature, is that as sensor dimensions decrease resonant frequency increases. However, sensitivity response measurements over this wide range of frequencies is beyond the limitations of our experimental setup which, for experimental setup version 1, has an upper bandwidth of 400 Hz and for version 2, an upper bandwidth of 5 KHz. In this study, the low-frequency sensitivity was measured for the WB21 Galfenol wire type, at lengths of 5 and 7.5 cm, and for the FN wire type, at lengths of 5 and 8 cm. Figure 62 shows a linear relationship between sensitivity and frequency between 50 and 250 Hz. The 5cm length device exhibits a slightly steeper slope than the 7.5 cm device. Projection of the slope reveals intersection at ~400 Hz which suggests that above 400 Hz, the shorter device exhibits higher sensitivity, whereas below 400 Hz, the 7.5 cm device exhibits higher sensitivity. Sensitivity in Figure 62 was captured for fixed test field amplitude of 0.25 Hz and a fixed DC bias field of 20 Oe. 91

104 Figure 62: Sensitivity as a function of frequency for 7.5 cm and 5 cm WB21 device. A 20 Oe bias field was applied constantly. The test field was maintained at 0.25 Oe RMS. Sensitivity as a function of test field frequency for the 8cm FN device is shown in Figure 63 for test field amplitudes of 0.1 and 1 Oe. These conditions were characterized at 0 and 1 Oe DC bias fields. The frequency response for this device is measured to be nearly perfectly flat, exhibiting a slope of ~0, from 25 Hz thru 400 Hz, for each condition. In comparing the 0.1 and 1 Oe RMS measurements, the lower amplitude test field demonstrates higher sensitivity, which agrees with the results in Figure 60b. Figure 64 displays sensitivity vs. frequency for a 5cm FN device for both 0.1 and 1 Oe RMS test field amplitudes, under a fixed 10 Oe DC magnetic bias. A similar slope trend is observed between the longer 8cm device in Figure 63, and the 5cm device in Figure 64, in comparison with Figure 62, exhibiting that the shorter device has slightly positive slope. This 92

105 trend suggests that smaller devices are better suited for higher-frequency applications whereas longer devices are more sensitive at lower frequencies. Figure 63: Sensitivity as a function of frequency for the 8 cm FN device. Test field amplitudes of 0.1 and 1 Oe RMS were measured at zero bias and 1 Oe DC bias conditions. 93

106 Figure 64: Sensitivity vs. frequency for the 5 cm FN device. Test field amplitudes of 0.1 and 1 Oe RMS were measured at zero bias and 10 Oe DC bias conditions. An interesting overlapping trend shows that the shorter devices, such as 5 cm WB21 and 5 cm FN, shown in Figure 62 and Figure 64, respectively, exhibit a slightly positive slope demonstrating that sensitivity increases with test field frequency. The longer devices, such as 7.5 cm WB21 and 8 cm FN, shown in Figure 62 and Figure 63, respectively, exhibit a slope closer to zero, demonstrating a flatter sensitivity frequency response at these frequencies. Presumably this behavior is due to the longer devices exhibiting a lower resonance frequency than the shorter devices. As such, the shorter devices exhibit a response that rolls off more quickly as f approaches 0 Hz which agrees with the trend show here. 94

107 2.7. Array Study It was hypothesized that use of multiple identical devices wired in series would increase the output voltage in a similar manner as series connection of batteries, or voltage sources. In this way, the output voltage was theorized to increase by a factor of n, where n is the number of devices. In this study, three identically manufactured, 5cm iron-nickel ME tube sensors are fabricated and series performance is investigated. The ME sensors were positioned in parallel to each other within the dual Helmholtz coil. The devices were spaced ~5.5 mm apart and subjected to a 100 Hz, 0.25 Oe RMS reference field superimposed on a 10 Oe static bias field using experimental setup version 1. Twisted-pair wire leads for each sensor were routed out of the Gauss chamber such that the array wiring could be manipulated. A diagram showing the three devices aligned in a parallel manner and wired in series is shown in Figure 65. Figure 65: Diagram showing three identically-manufactured 5 cm FN tube sensors connected in series. 95

108 Figure 66: Sensitivity measurements for individual and series configurations for three 5cm FN devices measured at 100 Hz, 0.25 Oe RMS under a 7.5 Oe magnetic bias field. The output sensitivity was measured for sensors FN1, FN2, and FN3, individually, then for sensors 1 and 2 wired in series, and finally for all three sensors wired in series as shown in Figure 66. Individual sensitivity for sensors FN1, FN2, and FN3 was measured to be 11.3, 10.7, and 10.7 mv/oe, respectively. Sensors 1 and 2 wired in series exhibited a sensitivity of 15.8 mv/oe demonstrating a 45% enhancement, on average, compared to individual devices. Sensitivity was measured to be 18.5 mv/oe for all three devices wired in series, demonstrating a ~70% enhancement. These results do not show the anticipated increase in sensitivity as a function of device count, n. For instance it was assumed that use of two devices would double the output sensitivity, however only a 45% increase is measured. The reason for this behavior is believed to be due to inconsistencies in the construction between devices which causes phase mismatch between individual devices of the array. The phase mismatch, caused by non- 96

109 symmetrical motion of piezoelectric materials between devices, leads to destructive interference of charge generated on each device. The noise floor at 100 Hz was measured to be extremely low, ~ 2 nt/ Hz, for devices measured both individually and in series. Negligible difference between configurations was observed. These results indicate that increased sensitivity can be realized by using the tubetopology devices in arrays. In addition, these ME composites, which requires no external power supply, are ideally suitable for use in large passive arrays. Due to the small scale diameter, these devices can be tightly packed to increase spatial resolution and used in magnetic mapping applications to provide high detail at mm scale. Moreover, the arrays of magnetoelectric FeNi/PZT tube sensors hold promise for use in low cost, scalable, magnetic detection systems with nano-tesla sensitivity cm FN ME Composite Highlights The 8cm FN device exhibits the highest reported zero-external bias sensitivity as of this writing. Depending on applied test field and frequency, device sensitivity as high as 16.5 mv/oe (1.65 V/cm-Oe) has been demonstrated, as in Figure 60.[66] This achievement has warranted further characterization of the 8cm FN device in regards to sensitivity, noise floor, and frequency response. Sensitivity as a function of bipolar magnetic bias field is shown in Figure 67. This plot reveals the true nature for high sensitivity under zero-external bias. The device prefers to exhibit a net magnetization, even prior to application of a magnetic field, as exhibited by the first few 97

110 data points of the virgin curve. Here the virgin zero-bias sensitivity is ~13.5 mv/oe, and after returning to 0 Oe from an applied +50 Oe, the zero-bias sensitivity increases only to ~14 mv/oe. By decreasing the magnetic field in the - Oe direction, demagnetization of the wire occurs until ~4 Oe at which point magnetic domain reversal occurs and settles under increasing - Oe. The difference between minimum sensitivity values is ~ 7.5 Oe indicating that under no applied bias field, hysteresis effects, specifically, magnetic remanence and coercivity, lock the device in a partially magnetized state, effectively equal to externally applying ~7.5 Oe, as shown in Figure 68. Interestingly, peak sensitivity of this device is exhibited under a magnetic bias field of 7.5 Oe. It is presumed that if the remanence and coercivity of iron-nickel wire could be increased, a shift in the sensitivity dependence on bias field would occur. This shift can be engineered such that the peak sensitivity intersects at zero bias. In other words, engineering of effective magnetic remanence and coercivity may act as substitute to magnetic bias field for enabling a maximum in dλ/dh where peak ME sensitivity is exhibited. Here, peak sensitivity is exhibited under a 7.5 Oe bias field to be ~ 18 mv/oe, demonstrating a ME coupling coefficient of 1.8 V/cm-Oe. 98

111 Figure 67: Sensitivity vs. magnetic bias field for the 8cm FN device. A 25 Hz, 10 moe test field served as reference. Figure 68: Single-polarity plot of sensitivity vs. magnetic bias field to emphasize effect of hysteresis on low-bias sensitivity. 99

112 Numerous efforts towards reducing the low-frequency noise floor of ME composites have been undertaken, namely by a DARPA effort called HUMS (Heterostructural Uncooled Magnet Sensors). As previously mentioned, great interest exists in measuring low-frequency magnetic signatures in the picotesla range that correlate with biomagnetic fields in the abdomen or in the brain, generated by neurons firing. As such, measurement of the noise floor, or pseudonoise floor, of the 8 cm device at low frequency was carried out. Figure 69 shows that this sensor exhibits an average noise floor less than 2 nt/ Hz at frequencies between 1 and 30 Hz. A 25 Hz, 10 moe test signal was applied for reference. Figure 69: Magnetic spectral density plot from 1 Hz thru 30 Hz demonstrating low-frequency pseudonoise floor response of the 8cm FN wire with applied bias of 7.5 Oe. 100

113 Frequency response from Hz thru 5 KHz is shown in Figure 70 for an applied test field of 1 Oe RMS. No external bias is applied to the sensor. A flat frequency response is exhibited between 500 Hz and 5 KHz. Below 500 Hz, sensitivity rapidly rolls off. As no magneto-electro-mechanical resonance (EMR) is observed in this figure, it is assumed that the EMR occurs at higher frequencies. The slightly positive slope of the frequency response curve further validates this point. Frequency response behavior of ME composites shows that below EMR frequency, the slope is positive whereas above EMR frequency, slope is negative as the upper bandwidth limit of the device is reached. Figure 70: Zero-bias frequency response from Hz thru 5 KHz of the 8cm FN sensor. The test field was set at 1 Oe RMS and frequency was swept. Log-plot (inset) is shown to emphasize low-frequency response. 101

114 The 8cm FN composite represents the flagship device developed in this work in terms of high sensitivity at zero bias and low noise floor. In future developments, this sensor holds the figures of merit for which new tube topology designs are compared with D15 Operational Mode Device Recently, investigation of fundamental piezoelectric properties has found that the shear piezoelectric coefficient d15 is ~440 pc/n for a c-axis oriented thin film of PZT and as high as ~494 pc/n for bulk ceramic samples.[67] These results shown an astonishing ~180% increase as compared with the d31 (-175 pc/n) piezoelectric coefficient, which serves as the operational mode for the vast majority of ME composites, including the tube-topology devices in this work. As such, ways to utilize the d15 piezoelectric coefficient to harness the greatest amount of chargegeneration per input-force are being considered. The d15 coefficient describes the shear, or torsional, charge displacement caused by an input strain, and it is also equal to its reciprocal term d51.[68] In the case of a PZT cylinder, or tube, the d15 piezoelectric coefficient can be obtained by detecting differential charge at short-length intervals along the shear y-direction of the exterior surface of the tube as it undergoes axial strain in the x-direction which is illustrated in Figure 71. Technically, the device operates in a d15 mode which is achieved through reciprocal elemental and material action. Polarization in the shear-yaxis (5) direction is illustrated below. The use of helical electrodes, placed perpendicular to the polarization vector and at a 45-degree angle to the y-axis, is required. It is important to note that as of this writing no ME composite has been fabricated to utilize the piezoelectric component in a d15 mode. An initial attempt to realize ME tube-topology composites operating in a d15 mode is described here. 102

115 Figure 71: Nomenclature for describing directions in a PZT crystal for a 3D system on the left and the XY plane on the right. The shear-y axis (direction 5) is shown by the polarization vector in the XY plane. The d15 device was fabricated using an iron-nickel magnetostrictive wire according to the same methodology as all other tube-topology composites except that no outer silver paint electrode was applied. Instead, to capture the separation of charge along the PZT outer surface area, a double-helical electrode was fabricated on the tube as shown in Figure 72. The electrodes were made by tightly winding 20-micron diameter gold wire around the tube. Great care was taken to keep the wires uniformly spaced, at 45 degrees, and tightly wound around the tube; however inconsistencies are apparent due to the nature of working with such small materials by hand. Pinhead sized drops of rubber cement were applied at opposite sides of the tube to prevent wire from unraveling. Otherwise, no additional adhesive was used. The device was polarized according to the same polarization procedure for d31 devices and checked for shorts using a digital multimeter. 103

116 Figure 72: D 15 mode device fabricated using iron-nickel magnetostrictive wire and PZT tube. a) Diagram showing the double helical electrode structure that was fabricated, (b), using 20 um gold wires tightly wrapped around the tube exterior. The d15 device was characterized using experimental setup version 2. A 400 Hz, 1.8 Oe RMS field served as the test field and reference. Standard bipolar sweeping of magnetic bias field was done and device sensitivity captured at each step. The same butterfly-shaped curve is observed in Figure 73, indicating hysteresis effects enable a boost to the zero-external bias state. In addition, the device exhibits enhancement to sensitivity at an optimal bias of 7.5 Oe which agrees with other iron-nickel wire type devices. The device exhibits a zero-bias sensitivity of 10.9 μv/oe and an optimal-bias sensitivity of 11.2 μv/oe, both of which are significantly smaller than the sensitivity values exhibited by the 5cm d31 FN sensor of 2.84 and 4.7 mv/oe, respectively. However, this result demonstrates the world s first ever ME composite to operate in a d15 mode and therefore serves as a proof-of-concept. 104

117 Figure 73: Sensitivity vs. magnetic bias field for the D 15 sensor. A 1.8 Oe RMS test field alternating at 400 Hz was used for reference. Despite the low sensitivity of this device, the noise floor was characterized within the limitations of the experimental setup for completeness. Note that there exist significant limitations in the ability to measure noise floor pertaining only to the device, which is detailed later in this chapter. Voltage spectral density measurements were captured while applying a 0.01 Oe RMS, 400 Hz reference field to the 5 cm FN d15 device. The frequency span was set to 50Hz (clipped in plot), centered at 400 Hz. Conversion between voltage spectral density and magnetic spectral density data results in the magnetic noise spectra as shown in Figure 74. The 400 Hz, 1 μt reference signal is shown to be approximately one order of magnitude above the noise floor, which is, on average, ~400 nt/ Hz. 105

118 Figure 74: Magnetic spectral density plot for the D 15 sensor. A 400 Hz, 0.01 Oe RMS magnetic field is applied for reference. The first-ever realization of a d15 magnetoelectric composite exhibits low figures of merit compared with its d31 ME counterparts. However, the proof-of-concept design may be improved upon in the following ways. Due to the difficulty in tightly winding the PZT with gold wire, it is suggested that electrodes be painted or applied lithographically. Secure contact between PZT and electrodes will ensure maximum charge collection and therefore boost sensitivity. The electrodes must be fabricated at a 45 degree angle to the y axis in order to detect the d51 coefficient. Ideally, the electrode would consist of symmetrical, equally spaced, helixes that spiral the entire length of the PZT tube at 45 degrees. An optimization study on electrode density may also be required. 106

119 This initial ME sensor holds promise to realization of improved ME composites utilizing the d51 mode and encourages future development of such devices Experimental Setup Considerations The list of resources available at CM3IC is extensive, albeit incomplete. Mentioned throughout this dissertation was the phrase within limitations of the experimental setup. Since no standardized magnetoelectric characterization platform exists, an experimental setup was designed at CM3IC from the ground up using available equipment. An initial design was first in use in late By 2011, the experimental setup had then gone through several evolutions before settling on design version 1 which was used to capture the majority of data presented here. However, as noise floor measurements became increasingly of interest, the system had to be modified to allow for an extra Gauss chamber and generation of uniform magnetic fields over greater lengths. It wasn t until version 2 that the first major noise floor contributions was able to be characterized as shown in Figure 75. Sensitivity measurements at CM3IC had been challenging to capture and repeatable within a high margin of error. Typically certain times of the day, or night, were best to capture data. As demonstrated in Figure 75, environmental noise was the major noise contribution, preventing accurate characterization of the device s noise floor. After several stop-gap attempts to reduce the effects of background noise, the entire testing platform was moved to a quiet environment outside of Boston. 107

120 Figure 75: Sensitivity vs. elapsed time for 5 days. Periodic background environmental noise is apparent during day. 10mV/Oe variations observed during daytime, 4 mv/oe at night. Noise floor measurements were resumed with minimal effects from background noise at which point the second major factor contributing to overall noise floor was discovered. After several attempts to detect sensor-specific noise floor, an analysis of the equipment s electronic noise was undertaken. Electronic noise of the SR770 in two different state, shorted-input and open-input was modeled and measured. 108

121 For the shorted-state, Johnson-Nyquist noise of the resistance of the short (~50 mohms) at room temperature were calculated and added to the noise floor specified in the instrument along with 1/f noise. Johnson-Nyquist noise was modeled using equation (2.14) where the voltage spectral density is a function of temperature (T) and resistance (R), and kb denotes Boltzman s constant. 4 (2.14) The vendor specified noise floor of the SR770, as specified in the user manual is 5 nvrms/ Hz. The 1/f noise was simply calculated in equation (2.15) where C, the DC offset constant is divided by frequency. (2.15) Modeling of the shorted-input condition is compared with experimental data and shown in Figure 76. The total modeled noise was calculated by summing noise contributions of Johnson-Nyquist, vendor specified, and 1/f sources. Two shorted-input cases were measured to exhibit excellent agreement with the modeled curves. One shorted-input case was for a 3 foot long BNC cable where the clip leads were simply shorted together. The other case involved shorting the BNC input jack with aluminum foil. In both cases the resistance contribution was so 109

122 minimal (~50 mohms) it wasn t included on the plot. Clearly, the modeled noise accurately predicts the electronics noise floor exhibited for the shorted-input case. Figure 76: Modeled and measured noise for the shorted-input case. Contributing factors for modeled noise are shown along with total noise (sum). Next, the open-input case was modeled. The same equations were used and the same three contributing factors accounted for. The only change was the new contribution of the 1 MOhm input resistance. The input impedance of the SR770 is specified, and measured, to be 1 110

123 MOhm. Therefore, the Johnson-Nyquist noise contribution now becomes a dominant factor in the total electronics noise. Modeled and measured data is shown in Figure 77 for the open-input state. Again, excellent agreement between modeled noise and measured noise is observed. The open-input noise floor was measured for two conditions; open at the BNC jack input on the front panel of the SR770 and open 1meter long BNC cable attached to the front panel jack. Figure 77: Modeled open-input state noise contributing factors and total, consisting of sum. Measured data is overlaid. These results demonstrate that the noise floor will be limited by the electronics when measuring devices that exhibit impedance greater than 1MegaOhm. It is well known that 111

124 magnetoelectric devices are fabricated to exhibit very high impedances, > 20 MOhms, in order to prevent leakage current, which causes reduction in output sensitivity. Therefore, the noise floor of this experimental setup is limited to the electronics noise floor which sits at ~130 nvrms/ Hz. To confirm this limitation, the 8cm FN device was connected to the SR770 and its output compared with previous measured and modeled data as shown in Figure 78. Figure 78: 8 cm FN wire voltage output noise floor is shown to be limited by the electronics noise floor, with exception to a few spurious environmental noise peaks. The conclusions drawn upon these results are such that the true noise floor of the ME composites cannot be fully characterized unless the entire noise floor profile is >130 nvrms/ Hz. For the majority of these devices, the noise floor bottoms out at the limit demonstrated by the 112

125 electronics such that only an effective, or pseudo-noise floor, can be measured. With that in mind, it can be stated that the noise floor measurements presented in this work show a high-limit, worst-case-scenario figure. Some consideration has gone into solving this issue and two main solutions are suggested. The dominant electronics noise contribution is due to the 1MOhm input impedance which generates large amounts of JN noise for ME composites connected directly to that port. The first potential solution is to build an impedance matching network that converts the high impedance of the ME composite to low output impedance (lower the better) which can be input to the SR770. This method would reduce electronics noise by approximately 1 order of magnitude to exhibit a noise profile as seen in Figure 76. The second solution, and preferable, is to use a low noise charge amplifier which has a low output impedance in line with the ME composite and SR770. Charge detection instead of voltage detection is common practice in piezoelectric devices. A rudimentary battery powered charge amplifier based in Linear Technology s LTC6240 amplifier was fabricated, as shown in Figure 79, which successfully reduced the 1 Hz noise floor from 1.33 nt/ Hz to 428 pt/ Hz for the zero-biased condition, representing a 67% decrease in noise floor as shown in Figure 80. Similarly, the charge amp reduced the 7.5 Oe bias, 1 Hz noise floor from 1.16 nt/ Hz to 578 pt/ Hz, demonstrating a 50% reduction in noise. It is suggested that use of a professional-grade charge amplifier will result in lower noise floor figures of merit. 113

126 Figure 79: Schematic of charge amplifier circuit (left) used to fabricate battery powered charge amplifier used in noise floor measurements (right). Figure 80: Low frequency noise floor measurements for zero-biased and 7.5 Oe biased 8cm FN sensor with and without charge amplifier. 114

127 Chapter 3. Conclusion The tube-topology magnetoelectric magnetic field sensors described in this work have achieved several exciting figures of merit. The highly sensitive zero-external bias operation demonstrated by these devices is the most exciting and technologically important achievement this work contributes to the field. A summary of additional contributions is shown in the following Research Summary The tube-topology ME composite offers numerous advantages over similar technologies and ME topologies as shown in Table 3. D31 and D33 Sensors were measured in-house using experimental setup version 1 and offer the most accurate direct comparison. Performance metrics of ME devices published by groups and institutions around the world is also included. 115

128 Table 3: Overview and Comparison of Device Performance Device Zero-Bias Sensitivity (mv/oe) Volume (cm 3 ) Zero-Bias Sensitivity Density / Zero-Bias 1-Hz Noise Floor (nt/ Hz) 8cm FN ~2 $ 5cm FN ~2 $ 7.5 cm WB ~2 $ D31 Sensor ~100,000 $$ D33 Sensor ~2000 $$ MEMS Cantilever[69] Cost ~ ~9.296E-7 ~12000 ~775,000 $$$ PZT/Metglas [70] <~2 >~0.084 ~23.8 >~2 $$ PMN- PT/Metglas [70] PZN- PT/Metglas [70] <~5 >~0.084 ~59.5 >~0.75 $$ <~1 >~0.084 ~11.9 >~0.5 $$ Feature Miniature, Directional, Low Freq. Miniature, Directional, Low Freq. Miniature, Directional, Low Freq. Miniature, Planar High optimally biased output High Sensitivity Density D33, Requires Charge Amp D33, Requires Charge Amp D33, Requires Charge Amp In this table, the tube-topology composites are compared with D31 Sensor, D33 Sensor and several others that represent types of state-of-the-art heterostructural composites. The FeNi wire type tube-topology composites outperform in nearly every category, except for volume. However, the FN devices exhibit higher sensitivity density than the miniature D31 Sensor. The WB21 device has a slightly lower sensitivity density than the D31 device. 116

129 The tube-topology composites hold immense potential for use as magnetic field sensors, as justified by this work. Most excitingly, they exhibit high sensitivity at zero-external bias field. This feature gives way toward realization of magnetoelectric magnetic field sensing platforms that, unlike hall-effect, flux gate, and SQUID magnetometers, operate completely passively. No bulky electromagnets, permanent magnets, or conditioning circuitry is required. The transduction of magnetic field energy to electric field energy occurs through a unique and cleverly engineered way that utilizes intrinsic material properties. In this work, the tube-topology ME composites are considered for use as magnetic field sensors, and characterized accordingly. However, these composites hold tremendous potential for use in numerous creative ways. For instance, the magnetization in the wire may be controlled by application of voltage across PZT tube thickness, via strain. In this way, a voltage controlled magnetic field generator may be realized and fabrication of such devices have already begun.[71] Similarly, voltage control of magnetization can be applied to devices that exhibit strong dependence on permeably, such as inductors and transformers. It is simple to envision a voltagetunable RF or chip inductor that utilizes the magnetoelectric effect to vary permeability. In an opposite manner, high frequency and RF capacitors that are magnetically tunable may also be realized. Global interest in magnetoelectric devices is growing. It is with great optimism that these works helps build upon the scientific community s knowledge base to ultimately improve the technology. 117

130 3.2. Improvements for Future Development In brief, the following points, suggestions, and comments are listed here as logical nextsteps towards for progressing the research within. 1) The full dynamic range, especially upper limit, has not been evaluated. Devices show linear response with test field amplitude up to 1.25 Oe, however saturation effects are inherent to these devices. Characterizations of these effects are of interest. 2) A broadband frequency sweep has not been applied to these devices. Devices thus far have shown relatively flat frequency response up to 5 KHz, however, for audio applications, characterization up to 20 KHz is required. Evaluation of sensor EMR may reveal interesting sensitivity figures of merit. 3) Pulse time response characterizing lag time between application of magnetic field and generation of output charge has not been evaluated. Such results are of great interest. 4) Thermal response characterizing an operational temperature range is valuable. 5) Directionality testing of these devices should be done. Presumably the tube-topology design preferentially reacts to axially applied fields. Evaluation of this may show that these devices are ideally suited for vector-magnetometry and be used in GPS and compass applications. 6) Investigation of application beyond magnetic field sensing, as previously mentioned, may reveal novel use for these composites. 118

131 Appendix A.1. Experimental Setup 1 Equipment List 1) Dual-nesting Helmholtz coil. 2) Dual-layered Gauss chamber. 3) Stanford Research Systems SR770 FFT Spectrum Analyzer. 4) Stanford Research Systems SR830 Lock-in Amplifier. 5) Sorensen DCR 80-12B DC Power Supply. 6) Lakeshore 421 Gauss meter. a. Hall Probe Model # MNT-4E04-VH. b. Gamma Probe Model # MLA-5006-HJ. 7) Keithley DMM ) Fluke DMM 87V. 9) Non-magnetic table-top vice grip with tweezers for mounting devices (or similar). A.2. Experimental Setup 2 Equipment List 1) Solenoid Coil. 2) Triple-layered Gauss chamber. 3) Stanford Research Systems SR770 FFT Spectrum Analyzer. 4) Sorensen DCR 80-12B DC Power Supply. 5) AMREL PS30-1.2D Programmable DC Power Supply. 6) Lakeshore 421 Gauss meter. a. Hall Probe Model # MNT-4E04-VH. b. Gamma Probe Model # MLA-5006-HJ. 7) Keithley DMM ) Fluke DMM 87V. 9) Non-magnetic table-top vice grip with tweezers for mounting devices (or similar). 119

132 A.3. LabView Program User Interface: 120

133 Block Diagram: 121

Approval Record NORTHEASTERN UNIVERSITY. Graduate School of Engineering

Approval Record NORTHEASTERN UNIVERSITY. Graduate School of Engineering Approval Record NORTHEASTERN UNIVERSITY Graduate School of Engineering Thesis Title: Dynamic Magnetostrictive Response of Heterostructural Magnetoelectric Magnetic Field Sensors. Author: Scott Matthew

More information

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head Magnetic and Electromagnetic Microsystems 1. Magnetic Sensors 2. Magnetic Actuators 3. Electromagnetic Sensors 4. Example: magnetic read/write head (C) Andrei Sazonov 2005, 2006 1 Magnetic microsystems

More information

5. Transducers Definition and General Concept of Transducer Classification of Transducers

5. Transducers Definition and General Concept of Transducer Classification of Transducers 5.1. Definition and General Concept of Definition The transducer is a device which converts one form of energy into another form. Examples: Mechanical transducer and Electrical transducer Electrical A

More information

Conductance switching in Ag 2 S devices fabricated by sulphurization

Conductance switching in Ag 2 S devices fabricated by sulphurization 3 Conductance switching in Ag S devices fabricated by sulphurization The electrical characterization and switching properties of the α-ag S thin films fabricated by sulfurization are presented in this

More information

Figure 4.1 Vector representation of magnetic field.

Figure 4.1 Vector representation of magnetic field. Chapter 4 Design of Vector Magnetic Field Sensor System 4.1 3-Dimensional Vector Field Representation The vector magnetic field is represented as a combination of three components along the Cartesian coordinate

More information

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring B. XU, S. BUHLER, K. L1TIAU, S. ELROD, S. UCKUN, V. HAFIYCHUK and V. SMELYANSKIY ABSTRACT

More information

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to: Serial Number 09/548.387 Filing Date 11 April 2000 Inventor Theodore R. Anderson Edward R. Javor NOTICE The above identified patent application is available for licensing. Requests for information should

More information

Supplementary Figure S1. Characterization using X-ray diffraction (XRD). (a) Starting titanium (Ti) foil used for the synthesis (JCPDS No ).

Supplementary Figure S1. Characterization using X-ray diffraction (XRD). (a) Starting titanium (Ti) foil used for the synthesis (JCPDS No ). Supplementary Figure S1. Characterization using X-ray diffraction (XRD). (a) Starting titanium (Ti) foil used for the synthesis (JCPDS No. 65-3362). (b) Oxidized Rutile titanium dioxide (TiO 2 ) obtained

More information

State of the Art Room Temperature Scanning Hall Probe Microscopy using High Performance micro-hall Probes

State of the Art Room Temperature Scanning Hall Probe Microscopy using High Performance micro-hall Probes State of the Art Room Temperature Scanning Hall Probe Microscopy using High Performance micro-hall Probes A. Sandhu 1, 4, H. Masuda 2, A. Yamada 1, M. Konagai 3, A. Oral 5, S.J Bending 6 RCQEE, Tokyo Inst.

More information

DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP. Michael Dickerson

DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP. Michael Dickerson DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP by Michael Dickerson Submitted to the Department of Physics and Astronomy in partial fulfillment of

More information

Spatial detection of ferromagnetic wires using GMR sensor and. based on shape induced anisotropy

Spatial detection of ferromagnetic wires using GMR sensor and. based on shape induced anisotropy Spatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy Behrooz REZAEEALAM Electrical Engineering Department, Lorestan University, P. O. Box: 465, Khorramabad, Lorestan,

More information

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION The use of giant magnetoresistive

More information

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER 1 PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER Prasanna kumar N. & Dileep sagar N. prasukumar@gmail.com & dileepsagar.n@gmail.com RGMCET, NANDYAL CONTENTS I. ABSTRACT -03- II. INTRODUCTION

More information

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation 238 Hitachi Review Vol. 65 (2016), No. 7 Featured Articles Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation AFM5500M Scanning Probe Microscope Satoshi Hasumura

More information

Body-Biased Complementary Logic Implemented Using AlN Piezoelectric MEMS Switches

Body-Biased Complementary Logic Implemented Using AlN Piezoelectric MEMS Switches University of Pennsylvania From the SelectedWorks of Nipun Sinha 29 Body-Biased Complementary Logic Implemented Using AlN Piezoelectric MEMS Switches Nipun Sinha, University of Pennsylvania Timothy S.

More information

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers Introduction: Active vibration control is defined as a technique in which the vibration of a structure is reduced or controlled

More information

Long-distance propagation of short-wavelength spin waves. Liu et al.

Long-distance propagation of short-wavelength spin waves. Liu et al. Long-distance propagation of short-wavelength spin waves Liu et al. Supplementary Note 1. Characterization of the YIG thin film Supplementary fig. 1 shows the characterization of the 20-nm-thick YIG film

More information

Inductive Sensors. Fig. 1: Geophone

Inductive Sensors. Fig. 1: Geophone Inductive Sensors A voltage is induced in the loop whenever it moves laterally. In this case, we assume it is confined to motion left and right in the figure, and that the flux at any moment is given by

More information

TECHNotes. Introduction to Magnetizing and Measuring Equipment. Some of the most frequently asked questions regarding magnetic materials are:

TECHNotes. Introduction to Magnetizing and Measuring Equipment. Some of the most frequently asked questions regarding magnetic materials are: Introduction to Magnetizing and Measuring Equipment Some of the most frequently asked questions regarding magnetic materials are: 1. Where can I get equipment to magnetize my magnets? 2. How much magnetizing

More information

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING H. Gao, M. J. Guers, J.L. Rose, G. (Xiaoliang) Zhao 2, and C. Kwan 2 Department of Engineering Science and Mechanics, The

More information

Design and Development of a Fluxgate Magnetometer for Small Satellites in Low Earth Orbit

Design and Development of a Fluxgate Magnetometer for Small Satellites in Low Earth Orbit Journal of Space Technology, Vol 1, No. 1, June 2011 Design and Development of a Fluxgate Magnetometer for Small Satellites in Low Earth Orbit Owais Talaat Waheed, Atiq-ur-Rehman AOCS Section, Satellite

More information

RISE WINTER 2015 UNDERSTANDING AND TESTING SELF SENSING MCKIBBEN ARTIFICIAL MUSCLES

RISE WINTER 2015 UNDERSTANDING AND TESTING SELF SENSING MCKIBBEN ARTIFICIAL MUSCLES RISE WINTER 2015 UNDERSTANDING AND TESTING SELF SENSING MCKIBBEN ARTIFICIAL MUSCLES Khai Yi Chin Department of Mechanical Engineering, University of Michigan Abstract Due to their compliant properties,

More information

AC Measurement of Magnetic Susceptibility

AC Measurement of Magnetic Susceptibility AC Measurement of Magnetic Susceptibility Ferromagnetic materials such as iron, cobalt and nickel are made up of microscopic domains in which the magnetization of each domain has a well defined orientation.

More information

Supplementary Figures

Supplementary Figures Supplementary Figures Supplementary Figure 1 EM wave transport through a 150 bend. (a) Bend of our PEC-PMC waveguide. (b) Bend of the conventional PEC waveguide. Waves are incident from the lower left

More information

Novel Metamaterials for Patch Antennas Applications

Novel Metamaterials for Patch Antennas Applications Novel Metamaterials for Patch Antennas Applications Theodore Zervos 1, Fotis Lazarakis 1, Antonis Alexandridis 1, Kostas Dangakis 1, Dimosthenis Stamopoulos 2, and Michalis Pissas 2 1 Institute of Informatics

More information

Large Signal Displacement Measurement with an Asylum SA Atomic Force Microscope Rev B

Large Signal Displacement Measurement with an Asylum SA Atomic Force Microscope Rev B Radiant Technologies, Inc. 2835D Pan American Freeway NE Albuquerque, NM 87107 Tel: 505-842-8007 Fax: 505-842-0366 e-mail: radiant@ferrodevices.com www.ferrodevices.com Large Signal Displacement Measurement

More information

CHAPTER 6 CARBON NANOTUBE AND ITS RF APPLICATION

CHAPTER 6 CARBON NANOTUBE AND ITS RF APPLICATION CHAPTER 6 CARBON NANOTUBE AND ITS RF APPLICATION 6.1 Introduction In this chapter we have made a theoretical study about carbon nanotubes electrical properties and their utility in antenna applications.

More information

Optimization of a Love Wave Surface Acoustic Device for Biosensing Application

Optimization of a Love Wave Surface Acoustic Device for Biosensing Application Optimization of a Love Wave Surface Acoustic Device for Biosensing Application Yeswanth L Rao and Guigen Zhang Department of Biological & Agricultural Engineering University of Georgia Outline Introduction

More information

Design, Fabrication, and Validation of an Ultra-Lightweight Membrane Mirror

Design, Fabrication, and Validation of an Ultra-Lightweight Membrane Mirror Design, Fabrication, and Validation of an Ultra-Lightweight Membrane Mirror Surya Chodimella, James D. Moore, Brian G. Patrick SRS Technologies, Huntsville AL, USA 35806 Brett deblonk, Dan K. Marker Air

More information

Generation of Sub-nanosecond Pulses

Generation of Sub-nanosecond Pulses Chapter - 6 Generation of Sub-nanosecond Pulses 6.1 Introduction principle of peaking circuit In certain applications like high power microwaves (HPM), pulsed laser drivers, etc., very fast rise times

More information

Supplementary Figure 1 High-resolution transmission electron micrograph of the

Supplementary Figure 1 High-resolution transmission electron micrograph of the Supplementary Figure 1 High-resolution transmission electron micrograph of the LAO/STO structure. LAO/STO interface indicated by the dotted line was atomically sharp and dislocation-free. Supplementary

More information

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION Nondestructive

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION A full-parameter unidirectional metamaterial cloak for microwaves Bilinear Transformations Figure 1 Graphical depiction of the bilinear transformation and derived material parameters. (a) The transformation

More information

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla Extremely high sensitivity of 0.1 nanotesla with field and gradient probe Measurement of material permeabilities

More information

Lab 1. Resonance and Wireless Energy Transfer Physics Enhancement Programme Department of Physics, Hong Kong Baptist University

Lab 1. Resonance and Wireless Energy Transfer Physics Enhancement Programme Department of Physics, Hong Kong Baptist University Lab 1. Resonance and Wireless Energy Transfer Physics Enhancement Programme Department of Physics, Hong Kong Baptist University 1. OBJECTIVES Introduction to the concept of resonance Observing resonance

More information

PFM Experiments with High Voltage DC/AC Bias

PFM Experiments with High Voltage DC/AC Bias PFM Experiments with High Voltage DC/AC Bias Support Note Shijie Wu and John Alexander Agilent Technologies Introduction Piezoelectric force microscopy (PFM) has found major applications in the study of

More information

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications System Options AC Susceptibility Magnetic Property Measurement System Many materials display dissipative mechanisms when exposed to an oscillating magnetic field, and their susceptibility is described

More information

Lab 4. Crystal Oscillator

Lab 4. Crystal Oscillator Lab 4. Crystal Oscillator Modeling the Piezo Electric Quartz Crystal Most oscillators employed for RF and microwave applications use a resonator to set the frequency of oscillation. It is desirable to

More information

Piezoelectric Sensors and Actuators

Piezoelectric Sensors and Actuators Piezoelectric Sensors and Actuators Outline Piezoelectricity Origin Polarization and depolarization Mathematical expression of piezoelectricity Piezoelectric coefficient matrix Cantilever piezoelectric

More information

Magnetic characterization of CoFe-based glass covered amorphous wires at high frequency. G. Ababei 1,2, H. Chiriac 1

Magnetic characterization of CoFe-based glass covered amorphous wires at high frequency. G. Ababei 1,2, H. Chiriac 1 Magnetic characterization of CoFe-based glass covered amorphous wires at high frequency G. Ababei 1,2, H. Chiriac 1 1 NIRDTP, Mangeron 47 Blvd, Iasi-700050, Tel. + 40 232 430680, e-mail: hchiriac@phys-iasi.ro

More information

Control of Sputter Process for Improved Run-to-run Repeatability

Control of Sputter Process for Improved Run-to-run Repeatability Control of Sputter Process for Improved Run-to-run Repeatability S. Ghosal, R.L. Kosut, J.L. Ebert, L. Porter SC Solutions, Santa Clara, CA 95054 E-mail ghosal@scsolutions.com D. Brownell, D. Wang Nonvolatile

More information

A Practical Guide to Free Energy Devices

A Practical Guide to Free Energy Devices A Practical Guide to Free Energy Devices Part PatD14: Last updated: 25th February 2006 Author: Patrick J. Kelly This patent application shows the details of a device which it is claimed, can produce sufficient

More information

MAGNETO-DIELECTRIC COMPOSITES WITH FREQUENCY SELECTIVE SURFACE LAYERS

MAGNETO-DIELECTRIC COMPOSITES WITH FREQUENCY SELECTIVE SURFACE LAYERS MAGNETO-DIELECTRIC COMPOSITES WITH FREQUENCY SELECTIVE SURFACE LAYERS M. Hawley 1, S. Farhat 1, B. Shanker 2, L. Kempel 2 1 Dept. of Chemical Engineering and Materials Science, Michigan State University;

More information

Part 2: Second order systems: cantilever response

Part 2: Second order systems: cantilever response - cantilever response slide 1 Part 2: Second order systems: cantilever response Goals: Understand the behavior and how to characterize second order measurement systems Learn how to operate: function generator,

More information

ECNDT We.2.6.4

ECNDT We.2.6.4 ECNDT 006 - We..6.4 Towards Material Characterization and Thickness Measurements using Pulsed Eddy Currents implemented with an Improved Giant Magneto Resistance Magnetometer V. O. DE HAAN, BonPhysics

More information

Magnetic tunnel junction sensor development for industrial applications

Magnetic tunnel junction sensor development for industrial applications Magnetic tunnel junction sensor development for industrial applications Introduction Magnetic tunnel junctions (MTJs) are a new class of thin film device which was first successfully fabricated in the

More information

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS 80 CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS 6.1 INTRODUCTION The proposed permanent magnet brushless dc motor has quadruplex winding redundancy armature stator assembly,

More information

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

Micro-sensors - what happens when you make classical devices small: MEMS devices and integrated bolometric IR detectors Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors Dean P. Neikirk 1 MURI bio-ir sensors kick-off 6/16/98 Where are the targets

More information

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION 18 CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION 2.1 INTRODUCTION Transformers are subjected to a variety of electrical, mechanical and thermal stresses during normal life time and they fail when these

More information

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [5895-27] Introduction Various deformable mirrors for high-speed wavefront control have been demonstrated

More information

Novel Demagnetization Method after Magnetic Particle Testing

Novel Demagnetization Method after Magnetic Particle Testing Novel Demagnetization Method after Magnetic Particle Testing Takuhiko Ito, Arihito Kasahara and Michitaka Hori More info about this article: http://www.ndt.net/?id=22254 Nihon Denji Sokki Co., LTD, 8-59-2

More information

Brown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER

Brown University Department of Physics. Physics 6 Spring 2006 A SIMPLE FLUXGATE MAGNETOMETER Brown University Department of Physics Physics 6 Spring 2006 1 Introduction A SIMPLE FLUXGATE MAGNETOMETER A simple fluxgate magnetometer can be constructed out available equipment in the lab. It can easily

More information

Development of A Novel Powder Cluster Wick Structure for LTCC Embedded Heat Pipes

Development of A Novel Powder Cluster Wick Structure for LTCC Embedded Heat Pipes Development of A Novel Powder Cluster Wick Structure for LTCC Embedded Heat Pipes Guangnan Deng, W. Kinzy Jones Hybrid lab, Department of Mechanical Engineering Florida International University, University

More information

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements Inka Buethe *1 and Claus-Peter Fritzen 1 1 University of Siegen, Institute of Mechanics

More information

INF 5490 RF MEMS. LN12: RF MEMS inductors. Spring 2011, Oddvar Søråsen Department of informatics, UoO

INF 5490 RF MEMS. LN12: RF MEMS inductors. Spring 2011, Oddvar Søråsen Department of informatics, UoO INF 5490 RF MEMS LN12: RF MEMS inductors Spring 2011, Oddvar Søråsen Department of informatics, UoO 1 Today s lecture What is an inductor? MEMS -implemented inductors Modeling Different types of RF MEMS

More information

describe sound as the transmission of energy via longitudinal pressure waves;

describe sound as the transmission of energy via longitudinal pressure waves; 1 Sound-Detailed Study Study Design 2009 2012 Unit 4 Detailed Study: Sound describe sound as the transmission of energy via longitudinal pressure waves; analyse sound using wavelength, frequency and speed

More information

Three-Axis Magnetic Sensor HMC1043L

Three-Axis Magnetic Sensor HMC1043L Three-Axis Magnetic Sensor HMC1043L The Honeywell HMC1043L is a miniature three-axis surface mount sensor array designed for low field magnetic sensing. By adding the HMC1043L with supporting signal processing,

More information

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON CONTACT STIMULATION OF RESONANT MODES Buzz Wincheski, J.P. Fulton, and R. Todhunter Analytical Services and Materials 107 Research Drive Hampton,

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

1088 IEEE SENSORS JOURNAL, VOL. 11, NO. 4, APRIL 2011

1088 IEEE SENSORS JOURNAL, VOL. 11, NO. 4, APRIL 2011 1088 IEEE SENSORS JOURNAL, VOL. 11, NO. 4, APRIL 2011 A Three-Axial Search Coil Magnetometer Optimized for Small Size, Low Power, and Low Frequencies Asaf Grosz, Eugene Paperno, Shai Amrusi, and Boris

More information

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor Development of a Low Cost 3x3 Coupler Mach-Zehnder Interferometric Optical Fibre Vibration Sensor Kai Tai Wan Department of Mechanical, Aerospace and Civil Engineering, Brunel University London, UB8 3PH,

More information

Answer Sheets Cover Page

Answer Sheets Cover Page page 1 of 17 Experimental Competition May 7, 2015 08:30-13:30 hours Answer Sheets Cover Page STUDENT CODE Additional number of writing sheets= Do not write below this line Part A Part B Part C Part D Part

More information

Density and temperature maxima at specific? and B

Density and temperature maxima at specific? and B Density and temperature maxima at specific? and B Matthew M. Balkey, Earl E. Scime, John L. Kline, Paul Keiter, and Robert Boivin 11/15/2007 1 Slide 1 Abstract We report measurements of electron density

More information

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE J.L. Fisher, S.N. Rowland, J.S. Stolte, and Keith S. Pickens Southwest Research Institute 6220 Culebra Road San Antonio, TX 78228-0510 INTRODUCTION In

More information

Lamb Wave Ultrasonic Stylus

Lamb Wave Ultrasonic Stylus Lamb Wave Ultrasonic Stylus 0.1 Motivation Stylus as an input tool is used with touchscreen-enabled devices, such as Tablet PCs, to accurately navigate interface elements, send messages, etc. They are,

More information

Inductive Conductivity Measurement of Seawater

Inductive Conductivity Measurement of Seawater Inductive Conductivity Measurement of Seawater Roger W. Pryor, Ph.D. Pryor Knowledge Systems *Corresponding author: 498 Malibu Drive, Bloomfield Hills, MI, 48302-223, rwpryor@pksez.com Abstract: Approximately

More information

Electronic supplementary material

Electronic supplementary material Electronic supplementary material Three-dimensionally Deformable, Highly Stretchable, Permeable, Durable and Washable Fabric Circuit Boards Qiao Li 1, and Xiao Ming Tao 1,2 * 1 Institute of Textiles and

More information

P H Y S I C A L P R O P E R T Y M E A S U R E M E N T S Y S T E M. Quantum Design

P H Y S I C A L P R O P E R T Y M E A S U R E M E N T S Y S T E M. Quantum Design P H Y S I C A L P R O P E R T Y M E A S U R E M E N T S Y S T E M Quantum Design S Y S T E M F E A T U R E S THE QUANTUM DESIGN PHYSICAL PROPERTY EASE OF USE MEASUREMENT SYSTEM (PPMS) REPRESENTS A UNIQUE

More information

Introduction to NVE GMR Sensors

Introduction to NVE GMR Sensors to NVE GMR Sensors Introduction In 1988, scientists discovered the Giant Magneto Resistive effect a large change in electrical resistance that occurs when thin stacked layers of ferromagnetic and nonmagnetic

More information

Review Energy Bands Carrier Density & Mobility Carrier Transport Generation and Recombination

Review Energy Bands Carrier Density & Mobility Carrier Transport Generation and Recombination Review Energy Bands Carrier Density & Mobility Carrier Transport Generation and Recombination Current Transport: Diffusion, Thermionic Emission & Tunneling For Diffusion current, the depletion layer is

More information

Power generation with laterally-packaged piezoelectric fine wires

Power generation with laterally-packaged piezoelectric fine wires Supplementary materials Power generation with laterally-packaged piezoelectric fine wires Rusen Yang 1, Yong Qin 1, Liming Dai 2 and Zhong Lin Wang 1, * 1 School of Materials Science and Engineering, Georgia

More information

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved. Single-turn and multi-turn coil domains in 3D 2012 COMSOL. All rights reserved. Introduction This tutorial shows how to use the Single-Turn Coil Domain and Multi-Turn Coil Domain features in COMSOL s Magnetic

More information

Development of the Electrical and Magnetic Model of Variable Reluctance Speed Sensors

Development of the Electrical and Magnetic Model of Variable Reluctance Speed Sensors Development of the Electrical and Magnetic Model of Variable Reluctance Speed Sensors Robert A. Croce Jr., Ph.D. 1, Igor Giterman 1 1 Harco Laboratories, 186 Cedar Street, Branford, CT 06405, USA Abstract

More information

Accurate Models for Spiral Resonators

Accurate Models for Spiral Resonators MITSUBISHI ELECTRIC RESEARCH LABORATORIES http://www.merl.com Accurate Models for Spiral Resonators Ellstein, D.; Wang, B.; Teo, K.H. TR1-89 October 1 Abstract Analytically-based circuit models for two

More information

NOISE IN MEMS PIEZORESISTIVE CANTILEVER

NOISE IN MEMS PIEZORESISTIVE CANTILEVER NOISE IN MEMS PIEZORESISTIVE CANTILEVER Udit Narayan Bera Mechatronics, IIITDM Jabalpur, (India) ABSTRACT Though pezoresistive cantilevers are very popular for various reasons, they are prone to noise

More information

Conventional geophone topologies and their intrinsic physical limitations, determined

Conventional geophone topologies and their intrinsic physical limitations, determined Magnetic innovation in velocity sensing Low -frequency with passive Conventional geophone topologies and their intrinsic physical limitations, determined by the mechanical construction, limit their velocity

More information

A Laser-Based Thin-Film Growth Monitor

A Laser-Based Thin-Film Growth Monitor TECHNOLOGY by Charles Taylor, Darryl Barlett, Eric Chason, and Jerry Floro A Laser-Based Thin-Film Growth Monitor The Multi-beam Optical Sensor (MOS) was developed jointly by k-space Associates (Ann Arbor,

More information

plasmonic nanoblock pair

plasmonic nanoblock pair Nanostructured potential of optical trapping using a plasmonic nanoblock pair Yoshito Tanaka, Shogo Kaneda and Keiji Sasaki* Research Institute for Electronic Science, Hokkaido University, Sapporo 1-2,

More information

Inductive versus magnetic position sensors

Inductive versus magnetic position sensors T E C H N I C A L W H I T E P A P E R Inductive versus magnetic position sensors Author: Mark Howard, General Manager, Zettlex UK Ltd File ref: technical articles/inductive vs. magnetic_rev_2.0 w w w.

More information

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT EE 1000 LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT 1. INTRODUCTION The following quote from the IEEE Spectrum (July, 1990, p. 29)

More information

PHYSICS OF SEMICONDUCTOR DEVICES

PHYSICS OF SEMICONDUCTOR DEVICES PHYSICS OF SEMICONDUCTOR DEVICES PHYSICS OF SEMICONDUCTOR DEVICES by J. P. Colinge Department of Electrical and Computer Engineering University of California, Davis C. A. Colinge Department of Electrical

More information

Simple Quartz Crystal Models: A Review

Simple Quartz Crystal Models: A Review Simple Quartz Crystal Models: A Review Wes Hayward, w7zoi, 2 May 2017 A recent Internet posting ask about quartz crystals and the way the properties, mainly stability, change as the package and size change,

More information

1 General Description

1 General Description AN534-1 AS534, AS536 Magnetic Sensor Circuits Multi-pole Magnet requirements APPLICATION NOTE 1 General Description This document provides a detailed explanation of the underlying principles for high resolution

More information

Measuring Batteries using the Right Setup: Dual-cell CR2032 and Battery Holder

Measuring Batteries using the Right Setup: Dual-cell CR2032 and Battery Holder Measuring Batteries using the Right Setup: Dual-cell CR2032 and 18650 Battery Holder Introduction Knowing the exact specifications when testing batteries or any other energy-storage device is crucial.

More information

New Materials and Method for Laser Trimmable NTC Thermistors

New Materials and Method for Laser Trimmable NTC Thermistors New Materials and Method for Laser Trimmable NTC Thermistors By David J. Nabatian Gene A. Perschnick Chuck Rosenwald KOARTAN EMC Technology Corporation Artek Corporation Microelectronic Interconnect Materials

More information

Fabrication and application of a wireless inductance-capacitance coupling microsensor with electroplated high permeability material NiFe

Fabrication and application of a wireless inductance-capacitance coupling microsensor with electroplated high permeability material NiFe Journal of Physics: Conference Series Fabrication and application of a wireless inductance-capacitance coupling microsensor with electroplated high permeability material NiFe To cite this article: Y H

More information

A NOVEL NEAR-FIELD MILLIMETER WAVE NONDESTRUCTIVE INSPECTION TECHNIQUE FOR DETECTING AND EVALUATING ANOMALIES IN POLYMER JOINTS

A NOVEL NEAR-FIELD MILLIMETER WAVE NONDESTRUCTIVE INSPECTION TECHNIQUE FOR DETECTING AND EVALUATING ANOMALIES IN POLYMER JOINTS ICONIC 2007 St. Louis, MO, USA June 27-29, 2007 A NOVEL NEAR-FIELD MILLIMETER WAVE NONDESTRUCTIVE INSPECTION TECHNIQUE FOR DETECTING AND EVALUATING ANOMALIES IN POLYMER JOINTS Sergey Kharkovsky 1, Emilio

More information

3-Axis Magnetic Sensor HMC1043

3-Axis Magnetic Sensor HMC1043 3-Axis Magnetic Sensor HMC1043 Advanced Information The Honeywell HMC1043 is a miniature three-axis surface mount sensor array designed for low field magnetic sensing. By adding the HMC1043 with supporting

More information

MgO MTJ biosensors for immunomagnetic lateralflow

MgO MTJ biosensors for immunomagnetic lateralflow MgO MTJ biosensors for immunomagnetic lateralflow detection Ricardo Jorge Penelas Janeiro Under supervision of Susana Isabel Pinheiro Cardoso de Freitas Dep. Physics, IST, Lisbon, Portugal Octrober 15,

More information

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION YASUHIKO MORI 1, YOSHIHIKO OBATA 1 and JOSEF SIKULA 2 1) College of Industrial Technology, Nihon University, Izumi

More information

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment) ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment) 1. In an A.C. circuit A ; the current leads the voltage by 30 0 and in circuit B, the current lags behind the voltage by 30 0. What is the

More information

Department of Electrical Engineering and Computer Science

Department of Electrical Engineering and Computer Science MASSACHUSETTS INSTITUTE of TECHNOLOGY Department of Electrical Engineering and Computer Science 6.161/6637 Practice Quiz 2 Issued X:XXpm 4/XX/2004 Spring Term, 2004 Due X:XX+1:30pm 4/XX/2004 Please utilize

More information

Intrinsic Semiconductor

Intrinsic Semiconductor Semiconductors Crystalline solid materials whose resistivities are values between those of conductors and insulators. Good electrical characteristics and feasible fabrication technology are some reasons

More information

AN ABSTRACT OF THE THESIS OF

AN ABSTRACT OF THE THESIS OF AN ABSTRACT OF THE THESIS OF Arien Sligar for the degree of Master of Science in Electrical and Computer Engineering presented on August 18, 2006. Title: On-Chip Crosstalk Suppression Schemes using Magnetic

More information

Experiment 4: Grounding and Shielding

Experiment 4: Grounding and Shielding 4-1 Experiment 4: Grounding and Shielding Power System Hot (ed) Neutral (White) Hot (Black) 115V 115V 230V Ground (Green) Service Entrance Load Enclosure Figure 1 Typical residential or commercial AC power

More information

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 20

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 20 FIBER OPTICS Prof. R.K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay Lecture: 20 Photo-Detectors and Detector Noise Fiber Optics, Prof. R.K. Shevgaonkar, Dept.

More information

General Study on Piezoelectric Transformer

General Study on Piezoelectric Transformer General Study on Piezoelectric Transformer 1 KWOK K.F., 1 DONG P., 1 CHENG K.W.E., KWOK K.W., 1 HO Y.L., WANG X.X. and CHAN H. 1 Power Electronics Research Center, Department of Electrical Engineering,

More information

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece. Jpn. J. Appl. Phys. Vol. 40 (2001) pp. 3646 3651 Part 1, No. 5B, May 2001 c 2001 The Japan Society of Applied Physics Estimation of Resolution and Contact Force of a Longitudinally Vibrating Touch Probe

More information

Technical Article. Inductive Versus Capacitive Position Sensors. C = A d

Technical Article. Inductive Versus Capacitive Position Sensors. C = A d Technical Article (Ref: ZET13_v1) 9 th June 2011 Inductive Versus Capacitive Position Sensors Some engineers are confused between capacitive and inductive position sensors. Both use a non-contact technique

More information

Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment

Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment Ziedan et al. 154 Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment H. Ziedan 1, J. Tlustý 2, A. Mizuno 3, A. Sayed 1, and A. Ahmed 1 1 Department

More information