Pivot-type Fixed Meter 110mm Angle [JIS C , RoHS Compatible Products] Wide Angle Meter. Series CAT. NO. VF-11M-03

Size: px
Start display at page:

Download "Pivot-type Fixed Meter 110mm Angle [JIS C , RoHS Compatible Products] Wide Angle Meter. Series CAT. NO. VF-11M-03"

Transcription

1 Pivot-type Fixed Meter 0mm Angle [JIS C 0-007, RoHS Compatible Products] Wide Angle Meter Series CAT. NO. VF-M-0

2 New Series 0mm Angle Wide Angle Meter VF-M Series Contents About Model Names... Features... VF-M List... Production Standards... Operating Environment... 4 Special Specifications... 4 Common Specifications for Meter with EL Plate Lighting... 4 DC Ammeter (Moving-coil Type) DVF-M... DC Voltmeter (Moving-coil type) DVF-M... 6 AC Ammeter (Rectifier Type <Mean Value Response of Effective Value Conversion Scale>) SVF-M... 7 AC Voltmeter (Rectifier Type <Mean Value Response of Effective Value Conversion Scale>) SVF-M... 8 AC Ammeter (Electronic Device Type, R.M.S.-Response) SeVF-M... 9 AC Voltmeter (Electronic Device Type, R.M.S.-Response) SeVF-M...0 AC Ammeter (Moving-iron Type, R.M.S.-Response) AVF-M... AC Voltmeter (Moving-iron Type, R.M.S.-Response) AVF-M... Wattmeter and Varmeter (Electronic Device Type, Time Sharing Multiplication Method) EVF-M/RVF-M... Factor Meter (Electronic Device Type, Phase Discrimination Method) UVF-M/UuVF-M...4 Standard Table of Wattmeter Measurement Range... Production Limits of Meters (Wattmeter, Varmeter)...6 Wattmeter, Factor Meter Misconnection Phenomena...7 Frequency Meter (Electronic Device Type) FVF-M...8 Shunt Outside Dimensions...9 Series Resistor Outside Dimensions...0 Indicator Symbols... Notice for New JIS Mark Products... Precautions for Handling Meters...4

3 About Model Names L... With Lamp Lighting E... With EL Plate Lighting V... When equipped with resistor for instruction adjustment... Front Dimensions 0 0 VF... Design Shape Wide Angle Shape Indicates the type of input electric quantity D... Direct current or voltage Se... Alternating current or voltage (R.M.S.-Response type) S... Alternating current or voltage (Mean value rectifier type) A... Alternating current or voltage (Moving-iron type) E...P or P power R...P or P varmeter power U...P or P balanced power rate Uu... P unbalanced power rate F... Frequency C...Tachometer

4 -M Details of Changes from Previous Product ( VF- Series). Mounting screws at the four corners of the meter changed from M6 to M size.. Meter terminal screws changed as follows. Ammeter, voltmeter, frequency meter M6 screws M4 screws Wattmeter, Varmeter, Factor Meter P, PW : M4 screws M4 screws P4W : M screws M4 screws. Scale characteristics of the electronic device type (M.R.S.-Response type) AC ammeter have been improved from non-linear wiring to linear wiring. Features. A long scale meter for indicating wide angles.. A stepped scale plate is used to remove any level difference between the scale and tip of the needle, resulting in accurate readings.. Meter that has a bright scale due to the wide cover lighting surface. 4. It is not affected by steel panels.. Can be manufactured with EL board (Electro-Luminescence Board) lighting. 6. Terminal cover is now equipped as standard. 7. It is now compatible with multi-setting set pointer models. Direct Current Alternating Current VF- M Series List Part Name Ammeter Voltmeter Reception Meter Ammeter Voltmeter Ammeter Voltmeter Ammeter Voltmeter Reception Meter P Wattmeter P Wattmeter P4W Wattmeter P Varmeter P Varmeter P4W Varmeter P Factor Meter P Balanced Rate Meter P Unbalanced Factor Meter P4W Factor Meter Frequency Meters Model Name DVF M SVF M SeVF M AVF M SVF M EVF M RVF M UVF M UuVF M FVF M VF M Operating Principles Permanent magnet Moving-coil type Rectifier type Electronic device type Moving-iron type Rectifier type Electronic device type Electronic device type Electronic device type Electronic device type Applicable Standards: JIS C 0-,,, 4,, 9 Accuracy Class s Page 6 / /8 4 8 Production Standards Can be manufactured to (mm) or 0 0 (mm) sizes. Please contact us for more details. Model Name Front Dimensions (Horizontal Vertical) (mm) JIS Symbol (JISC0) Scale Length (mm) Blur Angle Accuracy/Class Mounting Posture Recommended No. of Scale Divisions Pointer Shape Cover Material Cover Frame Color Base Material Scale Plate VF M 0 0 KWa 70 7 Refer to VF- M Series List Table (Upper Table) Vertical (Other than vertical: Specification required, e.g. 0 ) Division to division 7 VF Standard Pointer (See Next page) Methacrylic Resin Black (Munsell symbol: N-.) Blue/green color according to specifications (Munsell symbol: 7.BG 4/.) Body: ABS resin Terminals: PBT resin Aluminum plate with white coating (Scale lines and numbers are black) ) See p.6 for details on the recommended scale divisions. Insulation Test Between all circuits in a batch and outer casing More than 0 MΩ (00V mega tester) Between current circuit and voltage circuit More than M (at 00V mega) Voltage Test Between all measurement circuits in a batch and outer casing, and between current circuit and voltage circuit... maximum usable circuit voltage up to 600V. AC0V for seconds: CAT III 600V displayed at the bottom right of the scale plate. If the maximum usable circuit voltage of 600V is exceeded, (E+000) V (E: Maximum usable circuit voltage [V])

5 Pointer Shape Scale face Pointer Scale Plate (Aluminum board) Scale face Pointer EL Board Scale Plate Semi-transparent methacrylic board ( ) VF Standard Pointer Single scale and ( Single scale double printing ) Rod Pointer (for Multiple Scale) Operating Environment Operating Temperature Limits 0 C to+0 C, Accuracy Assurance Range: + C to +40 C Storage Temperature 0 C to +60 C Relative Humidity Less than 80% Operating Environment Indoor Installation Height 000m or less (See p. for details) Special Specifications (Can be manufactured to the following special specification by request.) Mounting posture other than vertical (Specification of installation angle required) With Red Set Pointer Single Setting Type, Multiple Setting Type (See P. for details) Special Scale: Conversion scale, zero center scale, colored scale, multiple scale, magnifed scale, specific symbol display, scale division increase in lines Rod pointer (Rod pointer is used for multiple scales.) EL plate lighting (Color: green or orange) (See below) Special processing (heat processing, etc.) Other special specifications Zero Center Scale rpm Multiple Scale Common Specifications for Meter with EL Plate Lighting EL plate impressed voltage: 00/0V AC (Please contact us for uses with 00/0V AC and 00/0V DC.) Outside Dimensions VF-ME 8 (Moving-iron Type) 0 (Moving-coil Type, Rectifier Type) 4 AVF-M Voltmeter Vent Hole 0. 6 Resistor for Sensitivity Adjustment ) Accessories are attached externally as shown below for meters with EL plate lighting. Unmarked items have accessories built-in, and the wiring method is as standard. See the following pages for details on the outside dimensions of accessories and the wiring methods. ( ) Specifications Accessories φ0 φ99 ± Flange Nut 4-M Mounting Screws 4-M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes φ0 AC Voltmeter (Moving-iron Type) Wattmeter Varmeter Factor Meter M-4 A Series Resistor ERG- Converter RRG- Converter URG- Converter Or UuRG- Converter 4

6 DC Ammeter (Moving-coil Type) Model Name DVF-M Specifications Measurement Range Value 00 μa 00 μa ma ma ma 0 ma 0 ma 0 ma 00 ma 00 ma A A A A A A A Weight Reception Meter Meter Input 4~0 ma 0~0 ma Weight ka~.9 DVF-M Internal Resistance kω. kω 80 Ω Ω Ω 8 Ω Ω Voltage drop: 00mV Sensitivity: Approx. 0mA Voltage drop: 60mV Sensitivity: Approx. 0mA Approx. 0.4kg Distributor DVF-M Internal Resistance Distributor 7Ω Not Required Ω Approx. 0.4kg ) Internal resistance value tolerance: ±0% (at C) Not Required Built-in External Remarks Connection to Shunt. Connect the shunt to the wires on the earth side.. See P.9 for details on the outside dimensions of the shunt. Instrument Lead Instrument lead is not included. Instrument Lead Resistance. Meters externally attached to shunts are normally adjusted to an instrument lead resistance of 0.0Ω. (Indicate LEAD 0.0Ω on the scale plate) Therefore, use wiring that is equivalent to 0.0Ω for the instrument lead.. Please provide separate instructions if the instrument lead resistance is to be a value other than 0.0Ω. When combining with a 60mV rated shunt, the instrument lead resistance can be manufactured up to.0ω specifications. If the wiring exceeds.0ω, combine with a high mv shunt.. If the instrument lead resistance is not clearly specified, the meter can be manufactured with a sensitivity adjustment variable resistor (VR). The adjustable range is up to.0ω for a 60mV meter. ) The model name of an meter equipped with VR is the same as the normal model name with V appended. E.g. DVF-MV Zero center meters and multiple-scale meters can also be manufactured. 0mV and 00mV meters with externally attached shunts can also be manufactured. Reference [Unit Ω (at 0 )] Wire Diameter Length m m m 4 m m 0 m 0 m Conductor Resistance Ω/ km 0.7 mm. mm mm mm mm ). The resistance values in the table above are applicable when the prescribed length of vinyl wire for wiring electric devices is installed as return wiring.. If the wiring exceeds 0m, calculate from the conductor resistance value column. E.g. For.0mm 6m, Ω 000 Outside Dimensions Table of Instrument Lead Resistance Resistor for Sensitivity Adjustment () φ0 φ99 ± φ0 DVF-M Connection Diagram 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout ) The DVF-MV model resistor for sensitivity adjustment must be used. When the shunt is built-in and not required + When the shunt is externally attached + Instrument lead + Shunt DC Ammeter DC Ammeter

7 DC Voltmeter (Moving-coil type) Model Name DVF-M Specification Measurement Range Value V. V V V 7. V 0 V V 0 V 0 V 7 V 00 V 0 V 00 V 00 V (600V) 70 V kv *. kv 4 kv kv kv kv 7. kv Weight DVF-M Consumption Current Series Resistor ma Approx. 0.4kg Built-in M-B M- M-4A M-6 Voltage Division Type Series Resistor * Series resistors than 600V are built in. * M-A type series resistors that exceed 600V but are less than 70V are externally connected. (Series connection, ma consumption current) * The JIS mark cannot be displayed for specifications that exceed 600V. Remarks Connection to Series Resistor. Meters over 70V must be connected with the voltage division type series resistor specified in the table to the left as shown in the figure below. ) M-6 series resistors must be connected to the earth using the G terminal. The G terminal is only available on the M-6 series resistor. There is no G terminal on other series resistors because the boxes are made of resin. ( ). See P. for details on the outside dimensions of the series resistors. Meter Sensitivity The meter sensitivity of DV voltmeters is ma (kω/v) as standard. Zero center meters and multiple-scale meters can also be manufactured. Meter Input for Reception Meter ~V Weight DVF-M Consumption Current Series Resistor ma Built-in Approx. 0.4kg Internal Resistance: kω Outside Dimensions φ0 φ99 ± φ0 DVF-M 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4 φ6 Panel Cutout Connection Diagram For a built-in series resistor (If 600V or below) + For an externally connected voltage division type series resistor (Over 70V) + + DC Voltmeter H M E G Voltage Division Type Series Resistor + DC Voltmeter 6

8 AC Ammeter (Rectifier Type <Mean Value Response of Effective Value Conversion Scale>) Model Name SVF-M Specifications Measurement Range Value 00 μa 00 μa ma ma ma 0 ma 0 ma 0 ma 7 ma 00 ma 00 ma 00 ma A A A 7. A Extern 0 Weight SVF-M VA Consumption Accessories 0.VA None None Direct Measurement Direct Measurement Use combination of CT and A (A) meter φ0 φ99 ± φ0 ka~4-m Mounting Screws Approx. 0.kg Remarks Using CT. Use combined CT and A (A) meter if A is exceeded.. When circuit voltage of 00V is exceeded at A or below, use combined CT and A (A) meter for insulation. Frequency Indicate the frequency when measuring AC frequencies outside of commercial frequencies. (JIS mark not indicated) (Can be manufactured from approximately 0Hz to 0kHz) Extended Scale Meter Meters attached with double, triple or -times extended scale to use for measuring the current flow of electric motor-class of starting current can be manufactured. Waveform Distortion If there is waveform distortion, use an electronic device type (SeVF type: M.R.S.-Response P9) that is less susceptible to waveform distortion. ) Scale calibration for rectifier-type meters is conducted via sine waves. Multi-scale meters can also be manufactured. SVF-M Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout Connection Diagram For Direct Measurement When Combined With a CT CT AC Ammeter AC Ammeter Telemetering For direct feed type telemetering, you can reduce line loss if the second rated value uses a A CT combined with a A meter. (The rated value of A is /.) To further reduce loss, use an AC current transducer combined with a DC meter. (For details on AC current transducers, see the AC current transducer catalog.) A(A) CT Auxiliary 0V or 0V AC A ± S S - + Current Transducer + DC Meter 7

9 AC Voltmeter (Rectifier Type <Mean Value Response of Effective Value Conversion Scale>) Model Name SVF-M Specifications Measurement Range SVF-M Value Current Consumption Series Resistor V V 7. V 0 V V 0 V Built-in 0 V 7 V ACmA 00 V 0 V 00 V 600 V 60 V VT combined 0 Weight Approx. 0.4kg kv~φ0 Direct Measurement Use a combination of 0V meter and VT. Remarks Using VT Use combined VT and 0V meter if 600V is exceeded. Usage example Meter: Scale 0~9000V, input 0~0V VT:6600V/0V Frequency Indicate the frequency when measuring AC voltage outside of commercial frequencies. (JIS mark not indicated) (Can be manufactured from approximately 0Hz to 0kHz, but limited to sine waves.) Meter Sensitivity Standard AC voltmeter sensitivity is ma (kω/v), but high-sensitivity meters can also be manufactured. Waveform Distortion If there is waveform distortion, use an electronic device type (SeVF type: M.R.S.-Response P0) that is less influenced by waveform distortion. Scale Calibration Conducted via sine waves. Multi-scale meters can also be manufactured. Outside Dimensions φ99 ± φ0 SVF-M 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4-φ6 Panel Cutout Connection Diagram For Direct Measurement (If 600V or below) When Combined With a VT (If 600V is exceeded) VT AC Voltmeter AC Voltmeter 8

10 Specifications Measurement Range Value 00 ma 00 ma 00 ma A A A 7. A 0 Weight SeVF-M VA Consumption Accessories 0.VA AC Ammeter (Electronic Device Type, R.M.S.-Response) None Direct Measurement Use combined CT and A (A) meter Model Name SeVF-M Remarks Waveform Distortion Electronic device type meters indicate the root-mean-square value without being influenced by waveform distortion. (However, the waveform distortion must be less than the third harmonic wave 0% of the fundamental wave" prescribed in JIS C0- to, 9.) Using CT. Use combined CT and A (A) meter if A is exceeded.. When circuit voltage of 600V is exceeded at A or below, use combined CT and A (A) meter for insulation. Extended Scale Meter Meters attached with double, triple or -times extended scale to use for measuring the current flow of electric motor-class of starting current Outside Dimensions ka~ Approx. 0.kg φ0 φ99 ± φ0 SeVF-M 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout Connection Diagram For Direct Measurement When Combined With a CT CT AC Ammeter AC Ammeter 9

11 AC Voltmeter (Electronic Device Type, R.M.S.-Response) Model Name SeVF-M Specifications Measurement Range Value 0 V 7 V 00 V 0 V 00 V 600 V 60 V SeVF-M Current Consumption Series Resistor Built-in Direct Measurement AC 4mA VT combined 0 Weight Approx. 0.47kg Use a combination of VT and 0V meter φ0 φ99 ± φ0 kv~4-m Mounting Screws Remarks Waveform Distortion Electronic device type meters indicate the root-mean-square value without being influenced by waveform distortion. (However, the waveform distortion must be less than the third harmonic wave which is 0% of the fundamental wave" prescribed in JIS C0- to, 9.) Using VT Use a combination of VT and 0V meter if 600V is exceeded. (Cannot be manufactured with a series resistor.) Usage example Meter: Scale 0~9000V, input 0~0V VT:6600/0V Meter Sensitivity Standard AC voltmeter sensitivity is AC 4mA. Outside Dimensions SeVF-M Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout Connection Diagram For Direct Measurement (If 600V or below) When Combined With a VT (If 600V is exceeded) VT AC Voltmeter AC Voltmeter 0

12 AC Ammeter (Moving-iron Type, R.M.S.-Response) Model Name AVF-M Specifications Remarks Using CT. Use combined CT and A (A) meter if 0A is exceeded.. When circuit voltage of 600V is exceeded at 0A or below, use combined CT and A (A) meter for insulation. Extended Scale Meter Use a double, triple or five-times extended scale meter-standard meter to measure the current flow of electric motor-class of starting current. Usage example For a triple extended scale AVF-M 0~00~(00)A(CT ratio 00A/A) ) In the case of extended scale meters, the 70% point on the scale length represents the measurement range (upper limit value of the effective measurement range), and the section that exceeds 70% up to 00% is the extended scale section. (Extended scale part intrinsic error: ±0% of indicated values) ) The red color extended scale lines are the points below for extended scale meters. Specifications Outside Dimensions φ0 φ99 ± φ0 ~ ~Measurement Extended Scale Meter Range Value Double Triple Five Times VA Consumption Weight 00 ma 00 ma 00 ma 00 ma 00 ma 400 ma 600 ma 000 ma 00 ma 000 ma 00 ma 00 ma A A A A Direct Measurement A 0 A A A Approx..VA 7. A A. A 7. A 0.6kg 0 A 0 A 0 A 0 A A 0 A 4 A 7 A Use combination of 0 ~ ka 0 ka 0 ka 0 ka CT and A (A) meter. ) The standard scale meters and extended scale meters shown below are standard specification displays. (For standard scale meters, the above measurement range is full-scale.) Scale Example AVF-M~Measurement Range Measurement Range Measurement Range 0 0 A. 00 Red Line 0 0 A. 00 Red Line 0 0 A Red Line Double-Extended Scale: Measurement range value is. times, double Triple-Extended Scale: Measurement range value is double, triple Five-times Extended Scale: Measurement range value is double, five times Scale Calibration Telemetering Conducted via sine waves. For direct feed type telemetering, you can reduce line loss if the second rated value uses a A CT combined with a A meter. (The rated value of A is /.) To further reduce loss, use an AC current transducer combined with a DC meter. (For details on AC current transducers, see the AC current transducer catalog.) AVF-M 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout Connection Diagram For Direct Measurement When Combined With a CT CT AC Ammeter AC Ammeter

13 AC Voltmeter (Moving-iron Type, R.M.S.-Response) Model Name AVF-M Specification Measurement Range Value 7 V 00 V 0 V 00 V 400 V 0 Weight Measurement Range Value 400V 00V 600V AVF-M VA Consumption Series Resistor 9VA AVF-M VA Consumption Series Resistor VA VA 8VA M-A M-B M- Connect meter and series transistor in a series for use ) For series transistor outside dimensions, see P AVF-M Voltmeter Vent Hole 6 φ0 φ99 ± φ0 M4 Terminal Screws Terminal Cover (Transparent Resin) 4- φ6-holes Panel Cutout kv~47± Approx. 0.7kg Built-in VT combined Direct Measurement Use a combination of 0V meter and VT When Series Resistor is used (when inputting directly into the meter without using VT) Remarks Using VT Use combined VT and 0V meter if 00V is exceeded. Usage example Meter: Scale 0~9000V, input 0~0V VT:6600/0V ) Models up to 600V can be manufactured with a series resistor as shown in the table below. Series Resistor The M-4 type series resistor is attached externally for products equipped with EL plate lighting. (See below) Scale Calibration Conducted via sine waves. Connection Diagram AVF-M Less than 00V More than 00V VT Outside Dimensions AC Voltmeter AC Voltmeter AVF-M 4-M Mounting Screws Hexagonal Nut with Flange Outside Dimensions of Accessory Connection Diagram AVF-ME (EL plate lighting with meter) M-4A Type Series Resistor (Accessories for Meter with EL Plate Lighting Use) Less than 00V More than 00V 7 Weight: Approx. 0.kg 64 0 Face Plate M-4A Type Series Resistor EL Light Plating Use VT M-4A Type Series Resistor EL Light Plating Use -φ. Holes AC Voltmeter AC Voltmeter Terminal Cap (Optional) M Screws

14 Wattmeter and Varmeter (Electronic Device Type, Time Sharing Multiplication Method) Model Name EVF-M (Wattmeter) RVF-M (Varmeter) Specifications Product Name P Wattmeter P Wattmeter P4W Wattmeter P Varmeter P Varmeter P4W Varmeter Model Name EVF-M RVF-M Outside Dimensions 4 0. Rating 0 VA 0 VA 0 VA 0 VA 0/ VA 0/ VA 0 VA 0 VA 0 VA 0 VA 0/ VA 0/ VA VA Consumption Voltage Circuit Current Circuit.VA.VA.VA per phase.va per phase.va per phase.va per phase.va.va.va per phase.va per phase.va per phase.va per phase EVF-M RVF-M (Built-in Transducer Type) 0.VA 0.VA 0.VA per phase 0.VA per phase 0.VA per phase 0.VA per phase 0.VA per phase 0.VA per phase 0.VA 0.VA 0.VA per phase 0.VA per phase 4- φ6-holes Weight Approx. 0.9kg Panel Cutout 9 6 Terminal Cover (Transparent Resin) φ0 0/60Hz Common Use 0/60Hz Common Use 0/60Hz Common Use 0 or 60Hz Required Designation 0 or 60Hz Required Designation 0 or 60Hz Required Designation Remarks Using VT, CT Use a combination of the 0VA rating meter with VT and CT if the rating on the left is exceeded. Measurement Range Value Select the measurement range from the wattmeter measurement range selection standards chart on P. Production Limits of Meter For the production limits of meters, see P6. Usable Voltage Range Rated voltage within ±% Varmeter Scale The standard scale of a varmeter is LEAD ~0~LAG kvar. ) Pulse meters(0~ kvar) are also producible. (For pulse meters, designate LEAD or LAG.) Meter Wiring. You cannot obtain a normal indicator if phase is reversed. Therefore, be sure to check the phase sequence of the bus and the polarity of VT and CT.. For phenomena related to mis-wiring, see P7. PW Wattmeter PW Wattmeters as listed on the left can be manufactured. φ0 φ99 ± Voltage rated value A meters can also be manufactured. Flange Nut 4-M Mounting Screws M4 Terminal Screws Connection Diagram Supply P With CT P CT P Circuit Supply VT P With VT, CT P CT Supply With CT P P P CT CT P Circuit Supply With VT, CT CT VT VT P P P CT P Wattmeter P Varmeter P Wattmeter P Varmeter P Wattmeter P Varmeter P Wattmeter P Varmeter S L S L S L S L S L S L Supply N With CT CT CT PW Circuit With VT, CT With CT P4W Circuit CT Supply N Supply Supply N N VT VT CT CT CT CT With VT, CT VT VTVT CT CT CT PW Wattmeter P P0 P S L S L PW Wattmeter P P0 P S L S L P4W Wattmeter P4W Varmeter P PP P S L S L S L P4W Wattmeter P4W Varmeter S L S L S L

15 Factor Meter (Electronic Device Type, Phase Discrimination Method) P Factor Meter Model Name UVF-M ( P Balanced Rate Meter) P Unbalanced Factor Meter UuVF-M ( P4W Factor Meter ) Specification Product Name P Factor Meter P Balanced Rate Meter P Unbalanced Factor Meter P4W Factor Meter Model Name UVF-M UuVF-M Scale Drawing.9 LEAD.7. Outside Dimensions 4 0. Scale LEAD LAG 0.~~0. COSφ JQ089 COS ~E.0 Rating 0 V A 0 V A.9 LAG.7. CAT III 600V VA Consumption Weight Voltage Circuit Current Circuit 0.8 V A. V A 0. V A per phase V A per phase 0.8 V A 0.8 V A 0.8 V A per phase 0.8 V A per phase Approx. 0.8kg 9 Terminal Cover (Transparent Resin) 6 0/60Hz Common Use 0 or 60Hz Required Designation Remarks Using VT, CT Use a combination of the 0VA rating meter with VT and CT if the rating on the left is exceeded. Usable Voltage Range Rated voltage within ±% For Small Current When circuit voltage is rated under 0% (A rating: less than A), it may not be possible to obtain a normal indicator. (Indicates a single scale if the power is off) Meter Wiring. A normal indicator cannot be obtained if the polarity is reversed. Therefore, be sure to check the phase sequence of the bus and the polarity of VT and CT.. For phenomena related to mis-wiring, see P7. Voltage rated value A meters can also be manufactured. Panel Cutout φ0 φ99 ± 6 4 φ Flange Nut 4-M Mounting Screws M4 Terminal Screws 4- φ6-holes Connection Diagram Supply With CT CT P Circuit Supply With VT, CT CT Supply With CT CT P Balanced Circuit Supply With VT, CT CT P P VT P P P P VT P P P Factor Meter P Factor Meter P Balanced Rate Meter P Balanced Rate Meter S S S S L L L L Supply With CT P Unbalanced Circuit With VT, CT CT Supply CT VT VT CT CT Supply N With CT P4W Circuit Supply CT CT CT N With VT, CT VT VTVT CT CT CT P P P P P P P P P P P Unbalanced Factor Meter S L S L P Unbalanced Factor Meter S L S L P4W Factor Meter S L S L S L P4W Factor Meter S L S L S L 4

16 Standard Table of Wattmeter Measurement Range Line Voltage VT Ratio Meter Intrinsic Watts Value CT Ratio A/ A 7. A/ A 0 A/ A A/ A 0 A/ A 0 A/ A 40 A/ A 0 A/ A 7 A/ A 00 A/ A 0 A/ A 00 A/ A 00 A/ A 400 A/ A 00 A/ A 70 A/ A 000 A/ A 00 A/ A 000 A/ A 000 A/ A 6 Or 667 W kw. kw kw. kw 4 kw kw 0 kw kw 0 kw kw 40 kw 0 kw 00 kw 0 kw 00 kw 0 kw 400 kw Using the Above Chart This standards chart is a resource for determining the measurement range values of wattmeters and varmeters, so P wattmeter standards are indicated. 0 V 70 Or 8 W 70 W. kw. kw. kw kw kw 6 kw 7. kw kw kw kw 0 kw 0 kw 60 kw 7 kw 0 kw 0 kw 0 kw 00 kw 00 kw kw kw. kw kw kw 4 kw 6 kw 8 KW 0 kw kw 0 kw 0 kw 40 kw 60 kw 80 kw 00 kw 0 kw 00 kw 00 kw 400 kw 600 kw 0 V 440 V 00 V 6600 V 440V/0V 00 V/0 V 6600 V/0 V kw 6 kw Or Or kw Or Or kw 667 W 8 W Or Or 8 W Or. kw.67 kw 667 W 8 W. kw 667 W. kw. kw kw. kw 4 kw kw 8 kw. MW. MW kw kw 6 kw 0 kw kw kw 4 kw 6 kw 8 kw kw. kw 4 kw kw 8 kw 0 kw kw kw kw 6 kw 0 kw kw 0 kw 4 kw 6 kw 8 kw kw (6 kw) (4 kw) 0 kw 0 kw 40 kw 60 kw 80 kw 0 kw kw 40 kw 0 kw 7 kw 00 kw 0 kw 0 kw 0 kw 60 KW 00 kw 0 kw 00 kw 40 kw 60 kw 80 kw 0 kw 0 kw (40 kw) 0 kw 7 kw 00 kw 0 kw 00 kw 00 kw 60 kw 00 kw 0 kw 00 kw (40 kw) 400 kw 0 kw kw (6 kw) 0 kw (4 kw) ( kw) (60 kw) 00 kw (40 kw) 00 kw 400 kw (480 kw) kw 0 kw kw 40 kw 0 kw 80 kw kw kw 0 kw 0 kw 60 kw 00 kw 0 kw 0 kw 40 kw 60 kw 80 kw 0 kw kw 40 kw 0 kw 80 kw 00 kw 0 kw 0 kw 0 kw 60 kw 00 kw 0 kw 00 kw 40 kw 60 kw 80 kw 0 kw (60 kw) (40 kw) 00 kw 00 kw 400 kw 600 kw 800 kw. MW 0 kw 400 kw 00 kw 70 kw MW. MW 00 kw 00 kw 600 kw MW. MW MW 400 kw 600 kw 800 kw. MW. MW (.4 MW) 00 kw 70 kw MW. MW MW MW 600 kw MW. MW MW (.4 MW) 4 MW 00 kw 0 kw (60 kw) 00 kw (40 kw) (0 kw) (.6MW) MW (.4 MW) MW 4 MW (4.8 MW) 0 kw 00 kw 0 kw 400 kw 00 kw 800 kw 0 kw 0 kw 00 kw 00 kw 600kW MW 00 kw 00 kw 400 kw 600 kw 800 kw. MW 0 kw 400 kw 00 kw 800 kw MW. MW 00 kw 00 kw 600 kw MW. MW MW 400 kw 600 kw 800 kw. MW (.6 MW) (.4 MW) MW MW 4 MW 6 MW 8 MW MW. MW 4 MW MW 7. MW 0 MW MW MW MW 6 MW 0 MW MW 0 MW 4 MW 6 MW 8 MW MW MW (4 MW) MW 7. MW 0 MW MW 0 MW 0 MW 6 MW 0 MW MW 0 MW (4 MW) 40 MW ) Numerical values inside parentheses indicate values that deviate from JIS standards, but can be manufactured. [] For P wattmeters, P4W wattmeters, and PW wattmeters, the measurement range upper limit values are displayed in the voltage ratios (VT ratio differences) and CT ratio differences in the table above. (There are three types defined for the same VT and CT ratios. Choose the appropriate type.) (E.g.) For a VT: 00V/0V, CT: 00A/A P wattmeter... select the appropriate one from 400kW, 00kW or 600kW from the table above. [] For P wattmeters, P varmeters, and P4W varmeters, the values displayed above are multiplied by /, and are multiplied by /4 for P varmeters ) For varmeters, read kw units as kvar. Scale is LEAD ~0~LAG kvar. Example: For a VT: 00V/0V, CT: 00A/A P varmeter... LEAD0~0~LAG0kvar or LEAD00~0~LAG00kvar (00 /) (00 /) (600 /) (600 /) ) For P varmeters or P4W varmeters with zero left meters, follow the values as displayed above, and for P varmeters with zero left meters, the values in the table above are multiplied by /. [] If the CT ratio exceeds the range listed above, (for example, VT: 00V/0V, CT: 000A/A P wattmeter) select a value from the CT: 00A/A row ( MW,. MW, MW) and multiply it by 0. ) In the situation above, scale indicators are 0MW, MW and 0MW. (It is preferable that the highest digits of scales are displayed) [4] If CT ratios do not correspond with those indicated above (for example, CT: 60A/A), use the calculation chart below to acquire the measurement range, then choose from among them the value with the best ending number. Measurement Range Value = Intrinsic VT Ratio CT Ratio ) Select a value indicated below from the intrinsic power value in the above calculation chart. However, intrinsic power values vary depending on meter type. Use the multiplier indicated below to calculate the value. Meter Types P Wattmeters, P4W Wattmeters, PW Wattmeters P Wattmeters, P Varmeters, P4W Varmeters Multiplier / ( for varmeters with zero left meters) P Varmeters /4 (/ for zero left meters) E.g. For a VT00V/0V, CT: 60A/A P wattmeter Measurement Range Value = (667W, 8W, kw or.kw) 00/0 60 / = 40kW, 00kW, 60kW or 400kW. [] Values of,.,.,,.,, 4,, 6, 7. or 8, or integers that are multiples of those 0 values are preferable selections for the upper range scale value. (JIS standards)

17 [6] Even when using a CT of A for the secondary current, the measurement range value is as indicated on the left (selection standards chart). ) If CT ratios do not correspond (for example, CT: 60A/A) with those indicated to the left (selection standards chart), follow calculation chart [4] below to calculate the measurement range value. However, intrinsic power values vary depending on meter type. Use the multiplier indicated below to calculate the value. Meter Types P Wattmeters, P4W Wattmeters, PW Wattmeters P Wattmeters, P Varmeters, P4W Varmeters Multiplier / /0 (/ for varmeters with zero left meters) P Varmeter /0 (/0 for zero left meters) Example: For a VT: 440V/0V, CT: 60A/A single-phase wattmeter Measurement Range Value = [(6W, 667W, 70W, 8W or kw) /0] 440/0 60/ = kw, 6kW, 8kW, 0kW or 4kW, but select either kw or 0kW. Production Limits of Meters (Wattmeter, Varmeter) The production range of wattmeters and varmeters can be manufactured according to the indicated range of intrinsic power values in the calculation chart below. Intrinsic Value [W] Measurement Range Value [W] VT Ratio CT Ratio E.g. VT: 6600V/0V, CT: 0A/A When measurement range value = 400kW 400kW Intrinsic Value W = 60 0 = 667W Product Name P Wattmeters, P Varmeters P Wattmeters, P Varmeters, PW Wattmeters P4W Wattmeters, P4W Varmeters Rating 0V A 0V A 0V A 0V A 0/ VA 0/ VA Production Range 00 ~ 6 W (var) 600 ~ 0 W (var) 00 ~ 0 W (var) 000 ~ 00 W (var) 00 ~ 0 W (var) 000 ~ 00 W (var) ) The meter production range for using a CT of A for the secondary current is the value indicated on the left multiplied by /. 6

18 Wattmeter, Factor Meter Misconnection Phenomena When using a measuring circuit with VT, CT for wattmeters, power factor meters, etc., a complete review will often show that misconnection due to the location where installation is applied is often the cause of indicating meter failure. There is only one kind of correct connection, but there are many cases which result in misconnection. Reference the figures below for examples of particularly common examples of misconnection phenomena. (Correctly connect phase sequence and polarity. Set phase rotation to an order of... Three-phase unbalanced power factor meters will be particularly inoperable.) Wattmeter (Electronic Device Type) () CT polarity is incorrect () CT is misplaced () VT polarity is altered CT K L k l K VT VT k U V W L l CT Supply u v w K CT L l k K k L l CT Supply u v CT K L k l K L k l CT w CT K L k l K VT VT k U V W L l CT u v w u v w w v u S L L S S L S L S L S L S L u Supply v w CT K L k l K k L l CT S L L S S L Wattmeter, normal time - largest scale point indicated Factor Meter (Electronic Device Type) CT K L k l K VT VT k U V W L l CT Zero point indicated (no shift) Zero point indicated (if there is a shift to the extent of -, %) Zero point indicated (if there is a shift to the extent of -0.%) () CT polarity is incorrect () CT is misplaced () VT polarity is altered Supply u v w K CT L l k K k L l CT Supply u v CT K L k l K L k l CT w K VT VT U V W k CT L l K k L l CT u v w u v w w v u S L L S S L S L S L S L S L CT K L k l Supply K k u v w L l CT S L L S S L Factor Meter, normal time - when power factor "" is indicated (or normal power factor) K K of CT shifts completely to the LEAD side of CT shifts completely the LAG side Indicates power factor "" (even if the power factor of the electrical circuit changes) u w LEAD-side VT indicates 0.6 points 7

19 Frequency Meter (Electronic Device Type) Model Name FVF-M Specification Scale 4~Hz ~6Hz 4~6Hz Weight Scale Drawing Scale Rating Model Name Rated Voltage 0V 0V 0V 0V 0V 0V FVF-M VA Consumption Converter VA VA VA Built-in VA VA VA Approx. 0.48kg 4~Hz ~6Hz Remarks Usable Voltage Range Rated voltage within ±% Using VT Use a combination of the 0V rating meter and VT if the circuit voltage rating on the left is exceeded. () Preliminary status of intrinsic error testing time: five minutes Scales outside those displayed on the left can also be manufactured. (However this is limited to between approximately 40Hz and 0kHz.) 4~6Hz FVF-M 46 4 Hz 4 6 Hz Hz 6 Outside Dimensions φ0 φ99 ± φ0 FVF-M 4-M Mounting Screws Hexagonal Nut with Flange M4 Terminal Screws 4-φ6 Terminal Cover (Transparent Resin) Panel Cutout Connection Diagram Rated Voltage Rated Voltage is Exceeded VT Frequency Meter Frequency Meter 8

20 Shunt Outside Dimensions Rated voltage drop 60mV However, 00mV may occur for the M-A model. Less than to A M-A Model Weight: Approx. 00g 0 One-touch Installation Terminal Cover (Transparent Polycarbonate Plate) ±0. 60 LINE METER - φ4. Holes 4-M. Screws Rating Shunt Model Name Less than A A to less than A A to less than 0A M-A M-A S-0A Continuous Rating 00% 0A~0A S-8A 00A~000A S-8 Continuous Rating 80% to less than 0A S-0A Model 0 to 0A S-8A Model 69 ± 0 ±0. -φ. Holes, φ Countersunk Depth C 6 Current Terminal Voltage Terminal -M Screw Current Rating Current Terminal ~0A 60~7A 00~0A -M6 pan head screws -M6 hexagonal bolts -M8 hexagonal bolts Name Plate ~00A 0A 00~0A Name Plate H H C Weight Approx. 0.9kg Approx. 0.7kg Approx. 0.kg H 6 H 00A to 70A S-8 Model 000A to 000A S-8 Model B ± B ± C F -M Terminal Screws F G ±0. C A F -M Terminal Screws A F Name Plate J G ±0.4 E D Name Plate D E 00A 400A 00A 600A 70A A B C D E F G J Terminal Screws Weight M Tapping M Tapping M 8 60 Approx. 0.kg M 8 60 M 60 Approx. kg M 60 M 60 Approx. kg 000A 00A 000A 00A 000A A B C D E F G Terminal Screws Weight M 60 M 60 M 60 M 90 M 90 Approx..kg Approx. 4kg Approx. kg Approx. 6.kg Approx. 8kg 4000A S-8 Model Weight: Approx. kg 000A S-8 Model Weight: Approx. kg 60 ± ± ± ±0. Current Terminal 8-M Bolt Voltage Terminal -M Screw 0 Current Terminal 8-M Bolt Voltage Terminal -M Screw Name plate Name plate 0 Connection Bus Example (4x Copper Bars: Width 0, Depth 0) Rated Voltage Drop Tolerance: ±.0% Connection Bus Example (4x Copper Bars: Width 0, Depth 0) Rated Voltage Drop Tolerance: ±.0% 9

21 Series Resistor Outside Dimensions M- Model Weight: Approx. 0g M-A Model Weight: Approx. 00g 80 70± ± Name Plate - φ. Holes AMP Fastening Terminal (87-Series Tab Brass Plate) One-touch Installation Terminal Cover (Transparent Polycarbonate Plate) Name Plate -M. Screws - φ4. Holes 4 Fire-resistant PBT Resin (Containing Glass) M-B Model Weight: Approx. 0.kg M- Model Weight: Approx. 0.kg 4 0± ± 0 E M H E M H 40 -M4 Screws - φ 4. Holes - φ 4. Holes -M4 Screws 47 9 Name Plate 4. 9 Name Plate. ) There are terminals on the M-B, M- and M-4A series resistors for the moving-iron type AC voltmeters. M-4A Model (M-4B Model) Weight: Approx. 0.kg H - φ. Holes M-6 Model Weight: Approx. 0.8kg ± 7.R 4- φ Holes E Name Plate M 7 H 0 47 ± 64 G E M 0 ± 0 -M Terminal Screws Dimensions indicated in parentheses ( ) are for the M-4B model. 7 (8) 4 Clamped Terminal Name Plate Name Plate M Terminal Screws -M4 Screws

22 Specified Items when Ordering Direct Acting Electrical Indicating Instrument. Pointer shape.... Scale List of Results: a. Standard pointer: Cannot be specified b. Rod pointer or knife shape pointer: Specfication required. Mounting posture a. Vertical ( ): Cannot be specified a. Same scale as measurement range values inherent to meter b. Scale that differs from measurement range values c. Recommended External Scale Division 00 yen per set if required. Delivery specifications: 00 yen for up to sets if required. 0 yen for each additional set. Joint inspection: b. Horizontal ( ) Diagonal ( ): Specification required. Cover color d. Single scale double printing Double scale double printing e. Unit Symbol 7. Others... a. Change class Separate quote. a. Black: Cannot be specified b. 7. BG/. : Specification required 4. Measurement Range Value... a. Measurement range values for standard table b. Measurement range values for non-standard μa ma A V kv W kw MW cos kvar Hz rpm m/min kpa etc. f. Color display (No. of colors, color band) Only available in red, green and yellow. b. Special conditions such as temperature, humidity, atmosphere, vibration, etc. When Set Pointer is Installed There are two types of set pointer methods, the conventional single setting type where the knob in the center of the meter is turned to perform settings, and the holder type multiple setting type (holder set pointer) for which multiple settings can be configured. The holder meter is inserted into the holder from the front of the meter, and held in place with screws. Specify the alphabetical letter (capital) to specify the color of the set pointer. For the multiple setting type (holder meter), specify the alphabetical letter (capital) to specify the color of the meter from the zero side (left side) of the meter scale. E.g.) Specify Holder set pointers RYBG" in order to specify the color of the holder meter as shown in the figure below. Set pointer color Red: R Yellow: Y Blue: B Green: G Single Setting Type (E.g.) VF-M with Set Pointer Multiple Setting Type (E.g.) VF-M with Holder Set Pointers RYBG 0±. Set Pointer (Red) 0±. Set Pointer (Yellow) Set Pointer (Blue) Set Pointer (Green) 0±. 0±. Set Pointer (Red) Indicator Mechanical Zero-point Adjuster Indicator Mechanical Zero-point Adjuster

23 Indicator Symbols Display indicator differences between new and old, and their meaning Old JIS Standard Symbols New JIS Standard Symbols Display Indicator Contents Types Symbols Reference the accompanying section Ampere A Rectifier-type - indicates that an item is affected by waveform Electronic Device Type - not affected by waveform Current Milliampere Microampere ma μa Moving-coil type Kiloampere ka Moving-iron type Volt V DC circuit and/or DC response measurement component Voltage Millivolt mv AC circuit and/or AC response measurement component Kilovolt kv DC and AC response measurement component Watt W ~ ~ Three-phase AC circuits Electrical Kilowatt kw ~E ~E N~E N~E N~E 0. ~E ~E N~E N~E N~E 0. Single measurement component for use with three-wire system circuits Two measurement component for use with unbalanced load three-wire system circuits Single measurement component for use with four-wire system circuits Two measurement component for unbalanced load four-wire system circuits Three measurement component for unbalanced load four-wire system circuits Class index 0. class Reactive Frequency Megawatt Var Kilovar Megavar Hertz Kilohertz MW var kvar Mvar Hz khz.0.0 Class index.0 class Phase Angle.. Class index. class Factor cos.. Class index. class Reactive Factor sin Applied to the synchroscope Class index.0 class Applied to the power factor meter Class index.0 class depending on span (Used with reception meter) Class index. class depending on span (Used with reception meter) Class index. class depending on span (Used with reception meter) Other Symbols Types Steel Plate Use Symbols Fe Scale plate used for vertically mounted meters Non-Steel Plate Use NFe Scale plate used for horizontally mounted meters Scale plate used for meters from the horizontal plane to Indicates normal use range from 80 ~00 in the initial position CAT III 600V Voltage test 0V seconds long. Voltage test 00V 0 Voltage test is not conducted R Z V CT A/ A VT V/ V R Z CT A/ A VT V/ V Indicates an externally attached shunt Indicates an externally attached series resistor Indicates externally attached serial impedance Indicates an externally accessory Indicates that a nominal circuit voltage of AC60 is exceeded (Indicated on labels of relevant items) DC60V Indicates an accessory and/or meter is high voltage. AC60V More than JIS Mark (JIS C0 is not indicated) JQA is an abbreviation for Japan Quality Assurance Organization, the certifying authority in Japan CT expressions are indicated in ratios (both sides are expressed in A) VT expressions are indicated in ratios (both sides are expressed in V)

24 Notice for New JIS Mark Products Meters bearing the new JIS mark are guaranteed for use in the conditions described below. Adhere to the following precautionary conditions when installing meters. The following are general conditions for the installation environment of meters. () Use in an indoor environment () Measurement category of the measurement circuit: III () Pollution level: (4) Installation height: 000m or lower () Temperature range: from to 40 C (6) Highest relative humidity until C: 80%. At 40 C it should be directly reduced to a general humidity of 0% The following installation conditions are in accordance with provisions JIS C 0-:007 (direct acting electrical indicating instrument) and JIS C 00-:00 (Safety requirements for electrical equipment for measurement, control, and laboratory use ). (Although products that operate in environments comprising of a wide variety of humidity and temperature can be found in our company s catalog, the acceptable range of temperature and humidity for safe usage is as prescribed above.) In order to assess compatibility requirements for the security of panel attachments for meters, assessments are made assuming the user is standing in front of the attached panel. For this reason, the inside of installed panels (parts of distribution boards, etc.) are excluded from general maintenance because it is assumed they are only handled by persons who have specialized knowledge. When installing panels for meters, make sure internal parts cannot be touched by general users. Furthermore, product fuses should be installed by a person who has undergone sufficient training, and the necessary consideration should be given to safety such as inserting fuses into voltage circuits.

25 Precautions for Handling Meters Be sure to note the following when handling the meter. (60 or over) because the plastic cover and base of the meter are easily affected by heat. The following points apply to the anti-static finish that has been applied to the transparent part of the cover. ) Remove dirt from the surface of the cover by gently wiping it with a damp towel or leather. ) Do not use alcohol, paint thinner, benzine or other such liquids that contain these chemicals to wipe the surface of the cover. (Doing so damages the coating, reducing its effectiveness.) ) Do not use polishing silicone, silicone cloth, or any other silicone-based cleaning agent to clean the surface of the cover. (Doing so reduces the effectiveness of the water-resistant finish.) 4) Do not store the meter by wrapping it in newspaper or other paper products. (Wrapping products in a hygroscopic material causes faster degradation.) Do not apply solder directly to meter terminals. Also, be sure not to solder the case when soldering connections. 4 PThinneraintl60 BAlcoho The case may be damaged through contact with chemicals (paint thinner, benzine, alcohol, etc.). Apply a commercially available antistatic agent if the antistatic agent has peeled or is no longer effective. If the anti-static agent has peeled or is no longer effective, even the slightest touch can cause the indicator to move, resulting in incorrect readings. The effectiveness of the anti-static finish may be negatively affected when the humidity is particularly low, such as during the dry periods in winter. The following anti-static agents can be applied easily. Riverson No. 0 with applicator (made by Tokyo Yakuhin Kakosei) Anti-Sta #80S spray-type (made by Tanaka Chemical Laboratory) enzine Avoid high temperature locations

26 ~Promotion of Environmental Issues~ Our company is fully committed to not using hazardous materials in our products. All of our main products are manufactured without the use of the six hazardous materials prescribed in the RoHS directives. However, while our VF-M Series is a fully RoHS compliant product, it has not yet received the "Ro" mark. Safety Precautions Only allow this product to be handled by people with sufficient knowledge and skill to ensure proper use. Carefully review any connection diagrams before soldering to ensure correctly soldered connections. Fully tighten screws. Loose screws may cause overheating or burnout. Mount the terminal cover after completing connections. Do not use if the specified rating is exceeded. Doing so may lead to malfunction or injury. Do not touch live parts of the product. Disconnect circuits during maintenance or inspections. ISO 900 Registration No. JSAQ 49 Main Office Shimoshinjo -chome 0-ban 7-go, Higashi Yodogawa Ward, Osaka City, -00 Sales Department Tel. 06 (69) 44 Fax 06 (68) 4 Tokyo Office Shin Yoshida Higashi 8-chome,47-ban 7-go, Kohoku Ward, Yokohama City, -008 Tel. 04 (4) 80~ Fax 04 (4) 989 Nagoya Office Nagoya SI Bld. Nishiki -chome 7-ban -go, Naka Ward, Nagoya City, Tel. 0 (9) 7780 Fax 0 (9) 778 Homepage

Meters. Ampere Meter. Volt Meter. Watt Meter. Var. Meter. Power Factor Meter. Frequency Meter. Demand Meter. Meter Relay.

Meters. Ampere Meter. Volt Meter. Watt Meter. Var. Meter. Power Factor Meter. Frequency Meter. Demand Meter. Meter Relay. Meters Ampere Meter Volt Meter Watt Meter Var. Meter Power Factor Meter Frequency Meter Outside Connection (Watt, PF, Var) 3 2 7 Receive Indicator Meter Demand Meter Meter Relay Meter Dimensions Meter

More information

Wide Angle METER L Series

Wide Angle METER L Series Wide Angle METER L Series L series are wide-angle meters. The series have three types, 110mm angle, 80mm angle and 65mm angle, and the series are in conformity with JIS C 1103 in panel cut-out size. With

More information

SAFETY PRECAUTIONS: Before use, read the following safety precautions

SAFETY PRECAUTIONS: Before use, read the following safety precautions [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions This instruction manual explains how to use your multimeter CD731, CD751 safely. Before use, please read this manual thoroughly.

More information

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE

More information

Basic Series Square Panel Meters Features Benefits

Basic Series Square Panel Meters Features Benefits Features Benefits Worldwide sales and service All panel meters can be supplied ex stock 1) Shunt resistors without protective cover (nominal current up to 1.5 ka) ASK 31.3 / ASK 412.4 current transformers

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Exercise MM About the Multimeter

Exercise MM About the Multimeter Exercise MM About the Multimeter Introduction Our world is filled with devices that contain electrical circuits in which various voltage sources cause currents to flow. Electrical currents generate heat,

More information

DM-III MULTITEST Power Quality Recorder

DM-III MULTITEST Power Quality Recorder DM-III MULTITEST Power Quality Recorder Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today

More information

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4 IV. Work Principle...7 V. Appearance Description...9 VI. Technical Characteristics 10 VII. Resistance Measurement Method..12 VIII.Battery

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL Table of Contents 1 SAFETY PRECAUTIONS Before use, read the following safety precautions.- 1-1 Explanation of Warning Symbols 001 1-2 Warning Messages for Safe

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DM-III Multitest & DM-III Multitest F Power Quality Recorders DM-III Multitest & DM-III Multitest F Power Quality Recorders CAT 600V TRUE RMSz Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

BOX TRANSDUCER TYPE CODE DESIGNATION

BOX TRANSDUCER TYPE CODE DESIGNATION TYPE CODE DESIGNATION TYPE CODE DESIGNATION SMALL SIZED AC TRANSDUCER TT2-90A series (1) TT2 (2) A - (3) (1) Kind of input (2) Kind of outer case and its dimensions Mark A or AE V or VE W WV S P SP F Kind

More information

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR MULTIMETERS

TECHNICAL MANUAL CALIBRATION PROCEDURE FOR MULTIMETERS TECHNICAL MANUAL CALIBRATION PROCEDURE FOR MULTIMETERS Distribution Statement C - Distribution authorized to U. S. Government agencies and their contractors for official use or for administrative or operational

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

Voltage Transformers type UMZ User s Manual, Operation and Maintenance Voltage Transformers type UMZ User s Manual, Operation and Maintenance ÿþþ Safety at first Safety instructions: Installation, connecting, operation and maintenance should be carried out by the authorised

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

MAVOWATT 4 Multifunction Power Meter

MAVOWATT 4 Multifunction Power Meter Operating nstructions MAVOWATT 4 Multifunction Power Meter 3-348-721-02 3/3.04 1 2 A V 3 4 5 6 Figure 1 2 GOSSEN METRAWATT GMBH Operating controls 1 Connection terminals Current, Voltage,, 2 Mirror scale

More information

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions 1/2 Regulations and standards 1/4 Technical descriptions 1/7 Rectangular indicators for direct current or voltage 1/7 96 x 48 mm and 48 x 96 mm with moving-coil movement 1/10 144 x 72 mm and 72 x 144 mm

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

Metal Film Resistor Kit

Metal Film Resistor Kit Ratings: Rated Power 0.5W at 70 C Max. Working Voltage 350V Max. Overload Voltage 700V Dielectric Withstanding Voltage 700V Rated Ambient Temp. 70 C Operating Temp. Range -55 C to +155 C Resistance Tolerance

More information

Metal Film Resistor Kit

Metal Film Resistor Kit Ratings: Rated Power 0.25W at 70 C Max. Working Voltage 250V Max. Overload Voltage 500V Dielectric Withstanding Voltage 500V Rated Ambient Temp. 70 C Operating Temp. Range -55 C to +155 C Resistance Tolerance

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

World-Class Accuracy & Measurement Range (40 Conventional Models)

World-Class Accuracy & Measurement Range (40 Conventional Models) AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)

More information

General Radio 1840-A. Output Power Meter

General Radio 1840-A. Output Power Meter PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT General Radio 1840-A Output Power Meter User and Service Manual WARNING OBSERVE ALL SAFETY RULES WHEN WORKING WITH HIGH VOLTAGES OR LINE VOLTAGES. Dangerous

More information

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n. MS8265 DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD ON/OFF LIGHT 1000V CAT II 600V CAT III MS8265 200K 2M 20M 20K 200M KHz 2K 20 200 2 20 200μ 200 20μ 750 2μ 1000 200n F 20n 10A 2m 200m 10 10

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

ANALOGUE MULTIMETER KEW 1109S

ANALOGUE MULTIMETER KEW 1109S INSTRUCTION MANUAL ANALOGUE MULTIMETER KEW 1109S Table of Contents Page 1. Safety Warnings... 1 Understanding Some of the Basics in Electrical Testing Before Using the Multimeter... 3 2. Features... 5

More information

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement Product Guide Analog Panel Meters in thermoplastic cases with slide-in-dials K Series 400.U.101.04 K Series PQ with Moving-Coil Movement VQ LSP LSG EQ with Moving-Coil Rectifier Movement with Moving-Coil

More information

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR Analogue Multimeter 1. Description Your is a professional analogue multimeter. It is ideally suited for field, lab, shop, and

More information

Table of Contents Title Page

Table of Contents Title Page Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols

More information

Model UT20B: OPERATING MANUAL Table of Contents (1)

Model UT20B: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Rotary Switch Display Symbols Measurement Operation A. AC Voltage

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

Instruction Manual for Digital Grounding Resistance Meter

Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4

More information

Model UT10A: OPERATING MANUAL Table of Contents (1)

Model UT10A: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement

More information

Introduction to the Laboratory

Introduction to the Laboratory Memorial University of Newfoundland Department of Physics and Physical Oceanography Physics 2055 Laboratory Introduction to the Laboratory The purpose of this lab is to introduce you to some of the equipment

More information

Standard Program Technical Description

Standard Program Technical Description Standard Program Technical Technical Square Panel Meters Square panel meters per DIN 43700 with quadrant scale, dull black or dull gray (RAL 7037) bezel per DIN 43718.. Interchangeable s Meter s scale

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1 Digital Multimeters ON / OFF power switch Continuity / Diode Test Function Resistance Function Ranges from 200Ω to 200MΩ Transistor Test Function DC Current Function Ranges from 2mA to 20A. AC Current

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

Model : OPERATING MANUAL Table of Contents (1)

Model : OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC

More information

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS DC POWER SUPPLIES We will discuss these instruments one at a time, starting with the DC power supply. The simplest DC power supplies are batteries which

More information

Pre-Laboratory Assignment

Pre-Laboratory Assignment Measurement of Electrical Resistance and Ohm's Law PreLaboratory Assignment Read carefully the entire description of the laboratory and answer the following questions based upon the material contained

More information

Table of Contents. Introduction...2 Conductors and Insulators...3 Current, Voltage, and Resistance...6

Table of Contents. Introduction...2 Conductors and Insulators...3 Current, Voltage, and Resistance...6 Table of Contents Introduction...2 Conductors and Insulators...3 Current, Voltage, and Resistance...6 Ohm s Law... 11 DC Circuits... 13 Magnetism...20 Alternating Current...23 Inductance and Capacitance...30

More information

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English Instruction manual SUN-PM100L SUN-PM100L Polishing Machine English Table: SUN-UM-TL-PM001 Version: A/0 Fiber Optic Solutions Provider Ⅰ Safety Precautions To ensure safe operation and maximize product

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero

More information

AC/DC ELECTRONICS LABORATORY

AC/DC ELECTRONICS LABORATORY Includes Teacher's Notes and Typical Experiment Results Instruction Manual and Experiment Guide for the PASCO scientific Model EM-8656 012-05892A 1/96 AC/DC ELECTRONICS LABORATORY 1995 PASCO scientific

More information

CONTENTS MS2033A. 1.Introduction Safety Information...01

CONTENTS MS2033A. 1.Introduction Safety Information...01 MS2033A AC Digital Clamp Meter User s Manual CAT III 600 V CONTENTS 1.Introduction...01 2.Safety Information...01 2.1 Precautions...02 2.2 Safety Symbols...03 3. Description...04 3.1 Front Panel...04 3.2

More information

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX: SFP-550 Operating Manual 296-1 MATSUHIDAI, MATSUDO-CITY, CHIBA 270-2214 JAPAN TEL: +81-47-388-6111 FAX: +81-47-388-4477 Safety Precautions To ensure safe operation and maximize product service life, observe

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

TV-15, 30 AMP (1 Form A) Power Relay

TV-15, 30 AMP (1 Form A) Power Relay VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012 SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM Unit Objectives Describe the structure of an atom. Identify atoms with a positive charge and atoms with a negative charge. Explain

More information

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement Product Guide Analog Panel Meters in thermoplastic cases with slide-in-dials K Series 400.U.101.06 K Series PQ with Moving-Coil VQ LSP LSG EQ with Moving-Coil Rectifier with Moving-Coil / Moving-Coil Rectifier

More information

INDEX IEC:

INDEX IEC: 60050-300 IEC:2001 173 INDEX A absolute absolute error... 311-01-05 (absolute) frequency deviation... 314-08-07 accessory accessory (of a measuring instrument)... 312-03-01 accessory of limited interchangeability...

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

Analogue Meters CQ0x07 series

Analogue Meters CQ0x07 series Analogue Meters CQ0x07 series CQ - Instruments with a moving coil and a rectifier CQ0107, CQ0207, CQ0307, CQ0407 & CQ0507 1) o For measurement of AC currents and voltages o Linear scale o Good read-out

More information

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30 Handleiding / Manual INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Multimeter from its packing, you should

More information

User's Manual. Clamp-on Power Datalogger. Model

User's Manual. Clamp-on Power Datalogger. Model User's Manual Clamp-on Power Datalogger Model 382060 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

ET-3888 True RMS Clamp Meter. User Manual

ET-3888 True RMS Clamp Meter. User Manual ET-3888 True RMS Clamp Meter User Manual Index Introduction... 3 Safety Notes... 4 Features... 5 Specifications... 6-8 Instrument Layout... 9 Measurement... 10 Maintenance... 11 Page 2 1. Introduction

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA12 EA19 EA17 EA16 EB16 APPLICATION EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or

More information

USER'S MANUAL DMR-2400

USER'S MANUAL DMR-2400 USER'S MANUAL DIGITAL MULTIMETER DMR-2400 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................

More information

DATA SHEET. Switchboard instruments,

DATA SHEET. Switchboard instruments, DATA SHEET Switchboard instruments, types Standard DIN sizes Quadratic instruments: Q48 Q144 Edgewise instruments: 48 x 24 144 x 72 mm Slim edgewise instruments: 72 x 24 144 x 36 mm Accuracy class 1.5

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

VCE VET ENGINEERING STUDIES CERTIFICATE II

VCE VET ENGINEERING STUDIES CERTIFICATE II Victorian Certificate of Education 2009 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words VCE VET ENGINEERING STUDIES CERTIFICATE II Written examination Section Wednesday 18

More information

Metal Film Fixed Resistor

Metal Film Fixed Resistor Specifications: Type : MCMF Rated Power : 0.25W at 70 C Max. Working Voltage : 250V Max. Overload Voltage : 500V Dielectric Withstanding Voltage : 500V Rated Ambient Temp : 70 C Operating Temp. Range :

More information

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine. Elderfield & Hall, Inc., www.kooltools.com 10901 McBride Lane, Knoxville TN, 37932. Phone: 865.671.7682. Fax: 865.671.7686. Email: bob@kooltools.com Kama Bandsaw AD 105S 110 Volt, Single Phase 2 ¼ HP Portable

More information

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX: SFP-550 Operating Manual 296-1 MATSUHIDAI, MATSUDO-CITY, CHIBA 270-2214 JAPAN TEL: +81-47-388-6111 FAX: +81-47-388-4477 Safety Precautions To ensure safe operation and maximize product service life, observe

More information

Table of Contents GDM-356. Page

Table of Contents GDM-356. Page Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The multimeter Structure Functional Buttons Display Symbols Measurement

More information

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation User s Manual 701932 Current Probe Yokogawa Electric Corporation 1st Edition Foreword Revisions Thank you for purchasing the 701932 Current Probe. This user's manual contains useful information about the

More information

Sales: Technical: Fax:

Sales: Technical: Fax: DATA SHEET Order code Manufacturer code Description 85-0733 n/a n/a The enclosed information is believed to be correct, Information may change without notice due to product improvement. Users should ensure

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

UT232. Operating Manual. Digital Power Clamp Meter

UT232. Operating Manual. Digital Power Clamp Meter UT232 Operating Manual Digital Power Clamp Meter Model UT232 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical

More information

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it

More information