WaveLink PDH Digital Microwave Radio Communication System User Manual VER 1.0

Size: px
Start display at page:

Download "WaveLink PDH Digital Microwave Radio Communication System User Manual VER 1.0"

Transcription

1 WaveLink PDH Digital Microwave Radio Communication System User Manual VER 1.0

2 Table of Contents Section 1 Product Introduction General Description System Equipments System Features IDU Description... 5 Section 2 Technical Specifications Front Panel of IDU Frequency arrangement of an IF Cable Section 3 Supervision Controls Operation Procedure HyperTerminal settings Operating HyperTerminal Parameter Setting HyperTerminal Tree Structure Manual Operation Manual commanding Item: Login system Item: Main Menu Item: Status Item: System Test Item: System Configuration Item: Remote Control Item: System Information Item: System Reset Item: Exit Item: Chinese Edition Front Panel Display Keyboard on front panel Section 4 Field Installation IDU Installation Electrifying Test BER Test One Way BER Test: (Fading-less) Loopback Test: (Fading-less)...31 Section 5 Maintenance and Troubleshooting Maintenance Check Troubleshooting Maintenance Notes Section 6 Packaging and Storage Equipment ID

3 6.2 Packaging requirements Shipment and Storage Handlings Appendix:Revision History Appendix:RF channel configuration for 5.8G Appendix:RF channel configuration for 13G Appendix:RF channel configuration for 15G Table of Figures FIGURE 1 WAVELINK PDH SYSTEM EQUIPMENTS... 4 FIGURE 2 IDU EQUIPMENT OUTLINE... 6 FIGURE 3 IDU FRONT PANEL OUTLINE... 9 FIGURE 4 FREQUENCY ARRANGEMENT OF AN IF CABLE FIGURE 5 RACK MOUNTING IDU FIGURE 6 ONE WAY BER TEST FIGURE 7 LOOPBACK BER TEST FIGURE 8 TROUBLESHOOTING FLOW CHART

4 Welcome to read this User Guide Thanks for using WaveLink PDH Digital Microwave Communication System. In order for the reader to get familiar with equipment and gain more information on operating guides, we highly recommend the reader to go through the outlined sections of this guide step by step. This guide would introduce the Indoor Unit (IDU), and the Outdoor Unit (ODU) and the radio communication system. 3

5 Section 1 Product Introduction 1.1 General Description WaveLink PDH digital microwave radio communication system is designed by YTMW Technologies Ltd. The system is a high-performance, low-cost, secure and reliable transmission products. The system includes Indoor unit (IDU), Outdoor unit (ODU, the RF unit), antenna and all basic accessories. WaveLink PDH system supply point-to-point radio connection in the telecommunications network, which is widely used in enterprise access, interconnect base stations, emergency communications, community access and relay connecting link. The WaveLink PDH (IDU) is designed for different RF Unit working in different RF frequency band, 7/8/13/15/18/23 GHz. And the IDU used the same IF interface to connect to all these ODUs through coaxial cable. 1.2 System Equipments 1.3 System Features Figure 1 WaveLink PDH System Equipments Advanced technologies, Modular Design, high reliability and performance Square-root Nyquist Roll-off Shaping, RS coding, QPSK modulation Low power consumption Rugged, compact, light weight IDU chassis, and all front wiring out High system gain. 4

6 Easy and Quick Installation, only one coaxial cable to connect IDU and ODU, automatic equalization (up to 300 m) Various mounting methods for IDU, ODU and Antenna Frequency Agility and Easy Tuning Transmit Power Control, 1dB step, ATPC System Flexibility, 2/4/8/16 E1 configurable capacity of IDU System Flexibility, (1+0) unprotected or (1+1) Hot-Standby, using the same IDU IDU is used commonly for 7/8/13/15/18/23 GHz Maintenance Facilities, Remote and local channel loop back (without external equipment) Local and remote supervision function on IDU 1.4 IDU Description WaveLink PDH is one part of PDH 2000X digit microwave radio communication system, which supplies point-to-point radio connection in the network. The IDU is designed for different RF Unit working in different RF frequency band, 7/8/13/15/18/23 GHz. The capacity of WaveLink PDH can be configured as 2x2.048Mbps, 4x2.048Mbps, 8x2.048Mbps or 16x2.048Mbps. A RS485 and an Ethernet Bridge way-side channel are supplied also. GENERAL FEATURES 1. Configured 2/4/8/16 E1 channels, 75ohm unbalanced and 120 ohm balanced. 2. One Service channel, telephone port, point-to-point calling. 3. Two external alarm inputs and 2 outputs in TTL. 4. User friendly, easy and simple to be installed and maintenance. 5. The art digital technology, modular structure design, high performance secure and reliable communications; self-testing capability U standard chassis with depth 220mm, light weight less than 3kg, the mounting flanges can be moved to front, middle and rear of the chassis for different installation on the rack. 7. Option 1+1 hot stand-by protection IDU in on 1U chassis only. Hitless switching depending on the radio link state. 8. Support SNMP network management protocol, Local Craft Terminal (LCT). 9. ATPC and RFU status real-time monitoring, cooperating with RFU. OPTION SELECTIONS 5

7 ID Options Selections Description Order Info. 1 Capacity 16xE1, configurable 2/4/8/16 E1 8xE1, configurable 2/4/8 E1 4xE1, configurable 2/4 E1 2 Configuration 1+0 Configuration 1+1 Hot Stand-by Protection 3 Supply Power +/- (20 to 72) VDC +/- (36 to 72) VDC 4 Ethernet (Way-side) None 10BaseT 5 IF Interface Transmit 310MHz / Receive 70MHz EQUIPMENT OUTLINE (1+0) Figure 2 IDU Equipment Outline 6

8 Section 2 Technical Specifications WaveLink PDH IDU SPECIFICATIONS GENERAL LED Indicators 5 LEDs (3 state LEDs for Power, IDU, ODU; Remote Alarm LED; Link state LED) Line Interface Standards Compliance Compliant to ITU-T Rec. G.703, G.823 Line Code HDB3 Impedance 75 ohm unbalanced or 12 ohm balanced IF Interface Transmit 310MHz, -7 to -2 dbm Receive 70MHz, -30 to 0 dbm IF Cable Connector N-Type Protection Connector Optional 8 pin RJ45 Auxiliary Data Aux Data Channels 2 Interface 1 RS485 and Ethernet Bridge Line Rate bps for RS485, full-duplex, asynchronous Interface 2 Ethernet Bridge, LAN port, RJ45 Line Rate 2 10BaseT, Over 200kbps, and Configurable, 1 to 7 E1 data used for the port Alarm I/O External Alarm Inputs 2 channels, TTL External Alarm Outputs 2 channels, TTL, Drive Current >10mA Connector 9 pin D-SUB NMS LAN Interface Type 10BaseT Ethernet Connector 8 pin RJ45 Maintenance Interface Standard RS232C, asynchronous Baud rate 19200bps Connector 9 pin D-SUB Electrical Input Supply Power +/- (38 to 72) VDC, or +/- (20 to 72) VDC Optional Connector ME , Taiwan DECA, 2 pins with flange Power Consumption <15W Protection Circuit 2A Fast-Blow Fuse Mechanical Chassis Standard 19 1U Chassis Outline Dimension 482mm(W) x 246mm(D) x44mm (H) Net Weight <3.5kg 7

9 CAPACITY OPTION 16E1 Capacity, configurable Traffic Connectors 16xE1, 8xE1, 4xE1, 2xE1 2xDB44/Female Accessory E1 Connection Wires 2 DB-to-BNC Connection Wires CAPACITY OPTION 8E1 Capacity, configurable Traffic Connectors 8xE1, 4xE1, 2xE1 2xDB44/Female Accessory E1 Connection Wires 1 DB-to-BNC Connection Wires PROTECTION OPTION Protection Type Switching 1+1 Hot Stand-by Protection < 5ms, hitless switching WaveLink PDH ODU SPECIFICATIONS SYSTEM Radio Frequency Frequency T-R Spacing supported, Maximum Tuning Range Band MHz (dependent upon T-R Range, GHz spacing),mhz 7 GHz to /161/ GHz to / GHz to GHz 14.4 to /420/490/644/ GHz 17.7 to / GHz 21.2 to /1200/ ANTENNA INTERFACE Radio Frequency Waveguide Type Flange Type Mating Flange Type Band 7 GHz R84(WR112) UDR84 PDR84 OR CDR84 8 GHz R84(WR112) UDR84 PDR84 OR CDR84 13 GHz R120(WR75) UBR120 PBR120 OR CDR GHz R140(WR62) UBR140 PBR140 OR CBR140 8

10 18 GHz R220(WR42) UBR220 PBR GHz R220(WR42) UBR220 PBR220 WaveLink PDH SYSTEM PARAMETERS Environment Operating Temperature -10 ~+50 Storage Temperature -40 ~+60 Humidity < 90%(non-condensing) System Performance Receive 12dB ATPC Range Configurable over full available ODU power range Protection Switch Mode By Manual, or Automatically Switch Conditions Refer to Receive C/N or Bit Error Rate Threshold Switch Bit Error Non-hitless Switching EMC Compliant with ITU-R F.746-3,YD System Configuration 1+0 non-protected or 1+1 Hot Stand-by protected Modulation Modulation Type QPSK FEC Concatenated Code: Reed-Solomon Network Management SNMP Protocol supported Maintenance and Monitor Service Telephone Telephone Port, Local-to-Remote Call Local Maintenance LCT, LCD and keypad, Command line terminal 2.1 Front Panel of IDU Figure 3 IDU Front Panel Outline No. Features Descriptions 1 Ground Connector Equipment grounding connector 2 ODU / IF IF interface, N-Type connector to be connected IDU to ODU 9

11 3 E1 TRIB 1-8 & E1 TRIB 9-16 with IF coaxial-cable. Traffic E1 interfaces: E1 TRIB 1-8: DB44 connector for E1 ports from 1 to 8. 75ohm unbalanced. E1 TRIB 9-16: DB44 connector for E1 ports from 6 to ohm unbalanced. For 2xE1 capacity: 1 to 2 ports are used and the other is disabled. For 4xE1 capacity: 1 to 4 ports are used and the other is disabled. For 8xE1 capacity: 1 to 8 ports are used and the other is disabled. For 16xE1 capacity: all ports are used. The E1 signal cable would connect to these connectors. 4 ALARM I/O External alarms port, 2 inputs and 2 outputs. 5 COMPUTER Supervision Interface, connect to the personal computer using (RS232) RS232 connecting wire. 6 ETHERNET ETHERNET: Ethernet bridge port for way-side data, RJ45. 7 NMS Network management Ethernet port, RJ45 8 PROTECTION Protection port. RS485 electric voltage 9 DATA (RS485) DATA (RS485): Asynchronous data port, RJ45, RS485 electric voltage 10 LED Lights 5 LEDs have two states: brighten and darken. PWR:Green light to indicate power on IDU:Red light to indicate IDU error, no light means normal ODU:Red light to indicate ODU error, no light means normal AIS:Red light to indicate remote station error, no light means normal LNK:Green light to indicate system traffic link is connected well, no light means the link is interrupted and failed to connect to remote station. 11 ESC Button to go backward or exit 12 UP Button to go upward or plus 1 to number in setting 13 DOWN Button to go downward or minus 1 to number in setting 14 ENTER Button to issue command or go into the sub menu. 15 LCD LCD Screen 16 FUSE Fuse for the supply power input. 17 EOW Port connected to a regular phone set 18 Power Socket Connected to supply power. 10

12 The ground end of supply power MUST be connected to the GND end of the socket. 19 PWR Power switch 2.2 Frequency arrangement of an IF Cable Figure 4 Frequency arrangement of an IF Cable 11

13 Section 3 Supervision Controls 3.1 Operation Procedure WaveLink PDH can be operated in three forms 1) LCD panel; 2) HyperTerminal; 3) NMS port. IDU without front LCD display should be system controlled by HyperTerminal Controls can be monitored via the LCD panel or the HyperTerminal 3.2 HyperTerminal settings User can use HyperTerminal on Windows to manage the equipment through supervision interfaces. The main content of control management includes: Login management, Data link testing, system alert, power and environmental status, equipment status, alert management, equipment maintenance and parameter settings. Parameters of supervision interface: Supervision interface adopts RS-232 to interface: Full duplex, Baud rate=19200 b/s; Stop bits=1.5 or 2; Data bits=8; Parity=None; Flow control=none. Main functions Login authorization management To stop illegal accessing the management system, the password management was used in the system. User can change the password. Special attention: User should log-off the system after operating to avoid illegal user from accessing. (Default: No Password, press ENTER key to login). Voltage status Users can monitor the internal operating voltage. The equipment will show relative alert when the voltage of some group out of Spec. Data-link test and Status warning Users can test and review the Branch Link and Multiplex Link of each E1, it includes Mux-link loopback test, interrupt check and AIS warning; Mux-link BER test automatic link switch and system delay re-start. Equipment status and Alarm management Users can check the equipment status and alarm while operating, and define the 12

14 notify way and alarm level. Equipment Maintenance and parameter setting Users can save the parameters to prevent parameter losing after power off. Users can set the parameter quite easily, such as to open/close the branch link; back up selection of multiplex link; set/change password and equipment name; save/reload equipment parameters Equipment Maintenance includes: hardware module troubleshooting and link testing. Do Troubleshooting to find out the root causes of hardware mal-functions quickly. Remote control Users can control the remote equipment through the local equipment. 3.3 Operating HyperTerminal Parameter Setting. HyperTerminal operating steps: Step 1: Run Start\All programs\accessories\communications\hyperterminal in Windows OS. Step 2: Select one port and set the parameter for communication: Baud rate=19200 b/s; Stop bits=1; Data bits=8; Parity=None; Flow control=none. 13

15 3.3.2 HyperTerminal Tree Structure Login System Main Menu Status Link Status Power Status RF Unit Status Test Link Loop Test Link Status Cancel All Loopback Local Loop Test Remote Loop Test Hardware Test RF PA Mute Configuration RF Unit General Settings E1 Function E1/Ethernet Ports Auto Alarm Function Auto LCM Screen Protect Change Equipment ID Address Ethernet Port Change Password Change Station Name Load Factory Settings Load Last Settings Save Current Settings Remote Access Back to Main Menu Access Remote Equipment Software Reset Timer Call Remote Equipment Info Reset Exit Chinese 中文 Manual Operation User can use HyperTerminal system to command supervision software. The 14

16 common method is to input alphabetical letters or integers such as 1, 2, and 3 etc, then press then enter key to dispatch orders. User can also use <ESC> key to go back to previous page or cancel present inputs. 0 command go back to previous order. 3.4 Manual commanding Item: Login system Login the HyperTerminal system, the page will show: WaveLink PDH Digital Microwave Communication System <Login System> Welcome To Visit Our WaveLink PDH Digital Microwave Communication System Press <0> Key To Login System It s necessary to follow the login procedure to enter the HyperTerminal system. Users need passwords to log into the supervision system. System allows 3 times, log-in. If invalid, users need to re-start the system Item: Main Menu The display window of Main Menu shows: 15

17 WaveLink PDH Digital Microwave Communication System <Main 1. Status 2. Test 3. Configuration 4. Remote Access 5. Info 6. Reset 7. Exit 8. 中文 (Chinese) Main Menu comprises ENTRANCE/EXIT/RESTART functions to interface with all system management. It s necessary to login for restart supervising tasks. Description of Commands: 1. Status // System status and warning management 2. Test // Proceed link and hardware functional testing 3. Configuration // Set up system parameters 4. Remote access // Control and de-control far end equipment 5. Info // System messages 6. Reset // Software to restart the system 7. Exit // Exit the text menu 8. 中文 (Chinese) // Enter Chinese version Item: Status System Status screen is shown below: 16

18 WaveLink PDH Digital Microwave Communication System <System 1. Link Status 2. Power Status 3. RF Unit Status >>Enter Command: 1 The status showing in current screen is NOT a real-time message; you should refresh the message by pressing the Space key 1 Link Status // Check the Link Status 2 Power Status // Check the Power Status Choose Link Status, the screen will show: WaveLink PDH Digital Microwave Communication System <Link Status> *. E1#1 Port Status: LOS *. E1#2 Port Status: LOS *. E1#3 Port Status: LOS *. E1#4 Port Status: LOS *. Service RF Link: Master *. Mux Link Status: SYN *. Modem Status:. Demodulator: s84 a80 efff0 n23. Tx IF LO: Locked. Rx IF LO: Locked Choose Power Status, the screen will show: 17

19 WaveLink PDH Digital Microwave Communication System <Power 1. Power (+5V ±5%): 5.11V 2. Power (+12V ±5%): 13.83V >>Enter Command: 1 This function is to display the voltage for each group Item: System Test System Test pages shows: WaveLink PDH Digital Microwave Communication System <System 1. Link Loop Test 2. Hardware Test 3. RF PA Mute: OFF(RF Power Output Normally) >>Enter Command: 1 1. Link Loop Test // Local and remote loop back over the data links. 2. Hardware Test // States of some hardware unit 3. RFPA Mute // on or off the FR PA 18

20 Link test screen shows: WaveLink PDH Digital Microwave Communication System <Link 1. Link Status 2. Cancel All Loopback 3. Local Loop Test 4. Remote Loop Test >>Enter Command: 1 The function is to test multiplex links and sub-links, local and remote included. For normal operation, make sure to close all loop functions after all tests were done. All loops should be closed when restart or re-load the system. 1. Link Status: //Enter Link Status Loop Test menu 2. Cancel All Loop 3. Local Loop test //Enter Local Loop test menu 4. Remote Loop test //Enter Remote Loop test menu Local loop screen shows: 19

21 WaveLink PDH Digital Microwave Communication System <Local Loop> 1. E1#1 Local Loop: Looped 2. E1#2 Local Loop: 3. E1#3 Local Loop: 4. E1#4 Local A. Mux Link Local Loop: Looped >>Enter Command: A Remote loop screen is shown below: WaveLink PDH Digital Microwave Communication System <Remote 1. E1#1 Remote Loop: Looped 2. E1#2 Remote Loop: 3. E1#3 Remote Loop: 4. E1#4 Remote Loop: >>Enter Command: 1 Looped means the pointed link is in looping stage. Blank space means the link is in normal condition. Use enter key to switch checking the looping status. Hardware Test screen is shown below: 20

22 Hardware Test: EEPROM...Normal IC1/IC2...Normal LIU Circuits 1)...Normal LIU Circuits 2)...Normal ADC Circuits...Normal Tel Circuits...Normal Modem...Normal IC6...Normal Test Done, Any Key to Continue... This function is to check EEPROM, IC1/IC2/IC3, LIU Circuits, ADC Circuits, Tel Circuits and Modem automatically. After command entered, the system will check the hardware module. The test result will be indicated in Normal or Error conditions Item: System Configuration The System Configuration page looks like: WaveLink PDH Digital Microwave Communication System <System 1. RF Unit 2. General Settings 3. Ethernet Port 4. Change Password: <NONE> 5. Change Station Name: Unnamed 6. Load Factory Settings 7. Load Last Settings 8. Save Current Settings After the parameter is changed, it won t save the setting automatically, need to perform the command Save Current Settings before parameters saving. 21

23 Password Change : Select 4 and press Enter, Please type password will be showed. The digit number of password is 1 to 8. Station Name: To identify machine ID, Maximum digits of Chinese character is 8. The page for General Settings looks like: WaveLink PDH Digital Microwave Communication System <General 1. Baseband Function 2. Change IP 3. Auto Alarm Function: On 4. Auto LCM Screen Protect: On 5. Change Equipment ID Address: External Alarm Output 1:Undefined (Output: LOW) 7. External Alarm Output 2:Undefined (Output: LOW) E1 Function page is shown below as: WaveLink PDH Digital Microwave Communication System <E1 Function> 1. E1 Port#1 Function: 2. E1 Port#2 Function: Disabled 3. E1 Port#3 Function: Enabled 4. E1 Port#4 Function: Enabled >>Enter Command: 2 You can change setting to Enabled or Disabled by pressing Enter 22

24 1. E1 Port Number: How many E1 channel is(are) for Ethernet 2. Ethernet Port: Disabled/Enable The setting for Ethernet Port: WaveLink PDH Digital Microwave Communication System <Ethernet Port> Z. Ethernet Mode: 3 >> Select E1 Channels For Ethernet 1. Channel E1#1: E1 Service Data 2. Channel E1#2: E1 Service Data 3. Channel E1#3: E1 Service Data 4. Channel E1#4: E1 Service Data >>Enter Command: 1 This function is to set which E1 channel is (are) for Ethernet Item: Remote Control Remote Control page is shown below: WaveLink PDH Digital Microwave Communication System <Remote Access> Operating On: Local Equipment! Station 1. Back To Main Menu 2. Access Remote Equipment 3. Software Reset Timer: Stopped 4. Call Remote Equipment >>Enter Command: 1 23

25 The system can control the remote equipment by performing the local control. If the communication link is normal, users can access remote interface by getting into the Remote Access menu. Users can also get out of the remote access interface by hitting Cancel command. If the communication link is interrupted and system shows no response, users need to activate the HyperTerminal menu Item: System Information Item: System Reset After the reset command is performed, the system parameter will be reloaded and system will be re-started. If system runs in normal condition please do not perform this command Item: Exit This command is for quitting the HyperTerminal program Item: Chinese Edition The page of Chinese Edit looks like: Use the English menu format to design the Chinese menu. 24

26 3.5 Front Panel Display Definitions to the Keyboard on front panel Esc (return or exit): Returning to up level menu or exit to stand-by interface (Up or plus 1): Move up menu in operation status or add one in setting status; (Down or minus 1): Move down in operation status or minus one in setting status; Enter (confirm): (1)Enter main menu from standby interface; (2)Choose sub-menu to enter ; (3)Save the setting; 3.6 Keyboard on front panel LCD displays messages and commands intuitively and user friendly to operate. Main menu is shown on right Displaying the brand name and logo. Press < > to enter the Main Menu. PDH WaveLink The Main Menu is shown on right 1. Status// System and alarm states 2. Test //Link and Hardware tests 3. Configuration // system settings 4. Remote Access// Far-end control 5. Information // General displaying 6. Chinese 中文 // Access the Chinese interface Main Menu 1. Status 2. Test 3. Configuration 4. Remote Access 5. Information 6. Chinese 中文 The Status menu is shown on right 1. Link and E1 ports // Check E1 link status 2. Modem// Check Modem 3. RF Unit Info // Check RF Unit Info 25 System Status 1. Link and E1 ports 2. Modem 3. RF Unit Info 4. Powers

27 4. Powers // Check Power Link status display 1. interrupt:no signal 2. losing:serious error code rate 3. all 1 : all 1 received within a frame cycle 4. normal:link is going in normal Link Status * E1#1: Normal/interrupt * E1#2: Normal/ interrupt * E1#3: Normal/ interrupt * E1#4: Normal/ interrupt * Mux Link: OK Modem display 1. s : Status 2. a : AGC 3. e : Error code 4. n Signal to noise ratio 5. The number behind s, a, e, n is Hexadecimal. Modem Status 1. Modem Status s9b a0a e0003 n19 2. Tx IF LO: Locked/Error 3. Rx IF LO: Locked/Error RF Unit display 1. StationType: 2. Tx Power: RF Info 1 Channel: xx 2 StationType: Low/High 3. Tx Power (dbm): xx Power display 1. Display voltage readings Powers +5V DC: 5.06V +12V DC: 12.53V System Test display 26 SystemTest 1 Link Loop 2 Baseband L_ Loop 3 Baseband R_ Loop 4 Cancel Test 5 Hardware Test 6 RF PA Mute: 7 Reset System!!!!

28 1. Link Loop //Enter Link Loops menu 2. Baseband L_Loop //Baseband Local Loop 3. Baseband R_Loop //Baseband Remote Loop 4. Cancel Test 5. Hardware Test //Equipment hardware test 6. RF PA Mute // On or off the RF PA 7. Reset System. //Reset the system Link Loop display 1. On - Link is in loop mode 2. Blank space - Link is in normal mode Link Loop 1 Local loop: On/ * Hardware Loop Baseband L_ Loop display 1. On - Link is in loop mode 2. Blank space - Link is in normal mode 3. L Cancel E1 Loops // Cancel local loop settings E1 L_Loops L E1#01 L_Loop: On/ L E1#02 L_Loop: On/ L E1#03 L_Loop: On/ L E1#04 L_Loop: On/ L Cancel E1 Loops Baseband R_ Loop display 1. On - link is in loop mode 2. Blank space - Link is in normal mode 3. R Cancel E1 Loops //Cancel remote loop settings E1 R_Loops R E1#01 R_Loop: On/ R E1#02 R_Loop: On/ R E1#03 R_Loop: On/ R E1#04 R_Loop: On/ R Cancel E1 Loops Hardware Test display The name of problem hardware would be given. If the hardware is found for something fault; otherwise, showing normal means circuits are working well. Hardware Test Circuits are OK! RF PA Mute page is shown on right 1. On means No RF Power Output 2. Blank space means RF Output Normally Setup OK: : No RF Power Output! //RF Output Normally 27 Cancel?... 4s

29 Reset System page is shown on right The system will be reset within 4 seconds, and press the key Enter to cancel the command. Configuration page is shown on right 1. RF Unit; 2. General Setting // 3. Ethernet // 4. E1 Ports// 5. Load factory // Load default setting; 6. Load Last // Load the setting of last time; 7. Save Setting // Save the settings. Configurations 1 RF Unit 2 General Settings 3 Ethernet 4 E1 Ports 5 Load Factory 6 Load Last 7 Save Settings General display 1. On means E1 is on open status 2. Off means E1 is on close status General 1 Auto Alarm: On/Off 2 Screen Protect: On/Off 3 Menu Loop: On/Off Ethernet display 1. Ethernet : None ( None is displayed if no Ethernet Module) 2. Press the key Enter to change setting to E1 Data or Ethernet Data Ethernet E1#1: E1 Data/Ethernet Data E1#1: E1 Data/Ethernet Data E1#1: E1 Data/Ethernet Data E1#1: E1 Data/Ethernet Data... RF unit display 1. Channel: Change the channel number 2. Tx Power: Change Tx Power 3. Apply New RF: Apply a new RF. RF Unit 1 Channel: xx 2 Tx Power(dBm): xx 3 Apply New RF 4 Rx Unit Info 5 Freq. Cfg 28

30 E1 Ports display Enabled: Function is avaiable Closed: Function is closed Press the Enter key to change the setting to Enable Or to Closed status. BB Function 1 E1#01 Fun: Enabled/Closed 2 E1#02 Fun: Enabled/Closed 3 E1#03 Fun: Enabled/Closed 4 E1#04 Fun: Enabled/Closed Load Factory display Press Enter key to load default settings Done! Load Last display Press Enter key to load the settings of Last time Please Wait Done! Save Settings display After setting finished, press Enter key to save The monitor screen will show Completed Please waiting Done! Remote display 1. press Enter to get in 2. Reset Timer to count down 3. Call Remote // key Enter to get in Remote * CurrentEquipment:Local 1 Access Remote 2 Reset Timer: Counting Down : 10 /Stopped 3 Call Remote System Info display 1. Show company related information 2. Show equipment related information System Info Model: WaveLink 29

31 Section 4 Field Installation 4.1 IDU Installation The indoor unit (IDU) shall be installed on a standard rack inside the link stations. The power and grounding wires should be well connected to meet their individual design specs. Make sure the power to be supplied is safely rated for the IDU. 4.2 Electrifying Test Figure 5 Rack mounting IDU After adjusting the antennas, the link devices in corresponding stations can be energized for running. If system runs in normal conditions, there will be no warning indicators flashing. 4.3 BER Test One Way BER Test: (Fading-less) A station to transmit and B station to receive No BER error occurs. B station to transmit and A station to receive No BER error occurs. 30

32 N*E1 Interface Multiplexer / Demultipler IF MODEM transceiver transceiver IF MODEM Multiplexer / Demultipler N*E1 Interface Figure 6 One Way BER Test Loopback Test: (Fading-less) Loop start from station A and conduct BER test at loop end of station B. No BER error occurs. Or route the other way around (loop from station B to station A). Figure 7 Loopback BER Test 31

33 Section 5 Maintenance and Troubleshooting 5.1 Maintenance Check Check on Power; Check cable connections; Check battery power (should be within 48v ±20%); Check light indicators; Check weather conditions (temperature, humidity, etc.) Conduct Maintenance check at least once a month. 5.2 Troubleshooting If something wrong with the equipment, please do not dismantle it without getting authorization from supplier. Always check thoroughly by following the recommended steps: Use monitoring software or user guide to check (Failure analysis flow chart) Same way to check the other link Check failure symptoms at both links Find out root causes at both links If user wants to fix the failure, please consult experienced technical staff for getting step by step problem-solving suggestions. 5.3 Maintenance Notes Maintenance process should be done by or under the guidance of authorized Professional engineers. Re-start the equipment (after power-off) and wait for 30 seconds, the equipment should operate back to normal. During maintenance session, parameters could be changed or revised. Be sure to change back to initial status after the completion of maintenance session. 32

34 Figure 8 Troubleshooting Flow Chart 33

35 Section 6 Packaging and Storage 6.1 Equipment ID Product Name, Model No., Serial No. must be clearly marked in a designated area on the Product. 6.2 Packaging requirements Packaging Check list User Guide Inspection Certificate 6.3 Shipment and Storage Handlings Follow packaging specs to choose the packaging material and packaging procedure to pack the finish product accordingly. User Guide, Inspection Certificate and Packing List should be included in box. Product would be delivered via airway, land and sea expressways by avoiding any hazardous situations such as: rain, flood, storm, snow or any possible natural impacts. Require good ventilation system in the storage room. Keep storage temperature in a range of -10~+40 and control humidity to be lowered than 85% and keep the products away from any hazardous chemical compounds or toxic gas. 34

36 Appendix:Revision History Revision Changes Date VER 1.0 Original

37 Rev1 WaveLink PDH System User Manual Appendix:RF channel configuration for 5.8G Channel Spacing (20MHz) Low Tx/High Rx(H) (MHz) High Tx/Low Rx (L) (MHz) Channel No. Tx frequency Rx frequency Channel No. Tx frequency Rx frequency

38 Rev1 WaveLink PDH System User Manual Appendix:RF channel configuration for 13G 13GHZ Frequency Range to 13250MHZ Number of channels 32 pairs Separation of channels 7 MHZ T-R Spacing 266 MHZ Capacity ;51.840; ; Mbits/s Channel Centeer Low High Channel Centeer Low High ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' '

39 Rev1 WaveLink PDH System User Manual ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' GHZ Frequency Range to 13250MHZ Number of channels 8 pairs Separation of channels 28 MHZ T-R Spacing 266 MHZ Capacity ;51.840; ; Mbits/s Channel Centeer Low High Channel Centeer Low High ' ' ' '

40 Rev1 WaveLink PDH System User Manual ' ' ' '

41 Rev1 WaveLink PDH System User Manual Appendix:RF channel configuration for 15G 15GHZ Frequency Range to 15350MHZ Number of channels 60 pairs Separation of channels 7 MHZ T-R Spacing 420 MHZ Capacity 2.048;2x2.048;8.448 Mbits/s Channel Centeer Low High Channel Centeer Low High ' ' ' ' ' ' ' ' ' ' ' ' ' ' '

42 Rev1 WaveLink PDH System User Manual ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' '

43 Rev1 WaveLink PDH System User Manual ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' GHZ Frequency Range to 15350MHZ Number of channels 15 pairs Separation of channels 28 MHZ T-R Spacing 420 MHZ Capacity 2.048;2x2.048;8.448 Mbits/s Channel Centeer Low High Channel Centeer Low High ' '

44 Rev1 WaveLink PDH System User Manual ' ' ' ' ' ' ' ' ' ' ' ' ' End ---

SGT-LP Series PDH Microwave Radio Technical Overview

SGT-LP Series PDH Microwave Radio Technical Overview SGT-LP Series PDH Microwave Radio Technical Overview System Overview 1 SGT-LP System Description Transmission Capacity: 4 x 2.048 Mb/s (4E1), 8 x 2.048 Mb/s (8E1), 16 x 2.048 Mb/s (16E1), 1 x 34 Mb/s (E3),

More information

Digital Microwave Radios

Digital Microwave Radios CM Digital Microwave Radios Operating at 6, 7, 8 & 11 GHz With Capacities of 4, 8, 16E1 E3, STM-1 & 2x100BaseT The CM offers bandwidth efficient long haul data transmission for common carrier, cellular

More information

Software Version 3.12

Software Version 3.12 SAF CFM-L4 Series Microwave Radio System Product Family Technical Description Software Version 3.12 SAF Tehnika A/S 2003 SAF CFM-L4 Series Product Family Technical Description SOFTWARE VERSION 3.12 SAF

More information

Alcatel 9600 USY/E. URBAN DRRS FOR FAST ETHERNET DATA LINKS GHz. New Product

Alcatel 9600 USY/E. URBAN DRRS FOR FAST ETHERNET DATA LINKS GHz. New Product Alcatel 9600 USY/E URBAN DRRS FOR FAST ETHERNET DATA LINKS 6.2-6.7-7-8-11-13-15-18-23-25-28-38 GHz New Product The ALCATEL 9600 USY/E family represents a new version of high capacity urban microwave Radios

More information

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual 5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical

More information

DIVERSE. WaveLink-SDH

DIVERSE. WaveLink-SDH WaveLink-SDH PRODUCT INTRODUCTION System Overview The Product comprises Indoor Units (IDUs) and Outdoor Units (ODUs) that together form the basis for an SDH fixed-wireless point-to-point microwave radio

More information

Data Sheet. A new generation of point-to-point SONET / PDH / Ethernet digital radios. Technical Specifications. 6 to 38 GHz ANSI digital hierarchy

Data Sheet. A new generation of point-to-point SONET / PDH / Ethernet digital radios. Technical Specifications. 6 to 38 GHz ANSI digital hierarchy 000 Data Sheet A new generation of point-to-point SONET / PDH / Ethernet digital radios The 000 series of point-to-point digital radios delivers highly flexible, highly reliable solutions for NxDS1 up

More information

X-Band Redundant LNA Systems

X-Band Redundant LNA Systems X-Band Redundant LNA Systems LRX-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

C-Band Redundant LNA Systems

C-Band Redundant LNA Systems C-Band Redundant LNA Systems LRC-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd AES/EBU Digital Audio Distribution Amplifier User Manual Revision 02 AES/EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIER Revision History: Revision Date By Change Description Applicable to: 00 15/03/2005 AL Original

More information

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification Appendix A Datum Systems PSM-2100/512 Satellite Modem Technical Specification PSM-2100 and PSM-512 VSAT / SCPC - Modem Specification Revision History Rev 1.0 6-15-97 Preliminary Release. Rev 1.1 10-10-97

More information

Alcatel-Lucent 9500 Microwave Cross-Connect

Alcatel-Lucent 9500 Microwave Cross-Connect Alcatel-Lucent 9500 Microwave Cross-Connect The Alcatel-Lucent 9500 Microwave Cross-Connect (MXC) is a flexible, multiservice wireless transport platform for medium- to high-capacity mixed traffic. Offering

More information

DRS/SM. Selectable Rates and Interfaces PDH Options

DRS/SM. Selectable Rates and Interfaces PDH Options HIGH CAPACITY MW SYSTEMS DRS/SM Digital Radio System/Split Mount (Hybrid) > SDIDU System Features Selectable Rates and Interfaces PDH Options > Up to 16 x E1/T1 > 100BaseTX/Ethernet: Scalable 1-100 Mbps

More information

Airmux-400 Broadband Wireless Multiplexer

Airmux-400 Broadband Wireless Multiplexer Data Sheet For North America Only Airmux-400 Point-to-point and multi point-to-point broadband radio solution for Cost-effective multi point-to-point encrypted wireless broadband multiplexer Net throughput

More information

Ku-Band VSAT Block Up Converters

Ku-Band VSAT Block Up Converters FEATURES Single box BUC output power levels to 10W RS485 M&C capability Accurate RF Power Monitoring Maintenance Free Operation +24VDC or +48 VDC input voltage OPTIONS 10W L-Band to Ku-Band Block Up Converter

More information

CUSTOMER MANUAL. ERDCHS1 Series. Indoor/Outdoor Channelized Digital Repeaters JANUARY 18,

CUSTOMER MANUAL. ERDCHS1 Series. Indoor/Outdoor Channelized Digital Repeaters JANUARY 18, CUSTOMER MANUAL ERDCHS1 Series Indoor/Outdoor Channelized Digital Repeaters JANUARY 18, 2018 WWW.EXCELWAVETECHNOLOGIES.COM 1-888-329-2878(Tel) 1-888-318-5528(Fax) Contents Disclaimer... 2 QUICK START...

More information

TELECOMMUNICATIONS. Y-Packet Y-Trunk Y-Split Y-Haul

TELECOMMUNICATIONS. Y-Packet Y-Trunk Y-Split Y-Haul TELECOMMUNICATIONS Y-Packet Y-Trunk Y-Split Y-Haul > 20 000 microwave radio have been produced for last 10 years > 100 international partners > 50 countries all over the world receive Youncta s products

More information

C-Band VSAT Block Up Converters

C-Band VSAT Block Up Converters FEATURES Single box BUC output power levels to 20W RS485 M&C capability Accurate RF Power Monitoring Maintenance Free Operation +24VDC or +48 VDC input voltage OPTIONS Antenna Mounting Kit Form A Summary

More information

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End FEATURES DESCRIPTION 7RU SSPA Chassis Teledyne Paradise Datacom s 7RU Indoor, High Power Rack Mount series of SSPAs represent the industry s highest power density and most reliable high power amplifier

More information

DIGITAL RADIO LINKS Freq ghz

DIGITAL RADIO LINKS Freq ghz Mod. a4d series DIGITAL RADIO LINKS Freq. 2 23 ghz Digital microwave Radio Link A4D series can be utilised to carry signals Studio Transmitter (STL), Transmitter Studio (TSL), in the distribution/contribution

More information

The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections.

The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections. The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections. L3 Telemetry& RF products (L3 T&RF) RCB-2000 is a compact, receiving system that combines two high-performance

More information

GPSR116 Quick Start Guide

GPSR116 Quick Start Guide GPSR116 Quick Start Guide .21 [ 5,3] [482,6] 18.12 [460,3] GPSR116 Quick Start Guide Rev 2.35 [8,9] Introduction Microlab s digital GPS repeater system can be used for cellular communications UTC synchronization

More information

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL The features mentioned in this Advanced OT-1000-HH Manual can be accessed only with the optional OT-NEC-A, Network Element

More information

RADITEK INC. code -g11

RADITEK INC. code -g11 code -g11 RM&C Software Remote Monitoring & Control for Desktop Installation and Operation Manual Rev. 17 Sep 2011 TABLE OF CONTENTS CHAPTER 1... 1 GENERAL INFORMATION... 1 1.1 INTRODUCTION... 1 1.2 SYSTEM

More information

LBI Installation & Operation

LBI Installation & Operation Installation & Operation EDACS Power Monitor Unit ericssonz CONTENTS TABLE OF CONTENTS Page INTRODUCTION... 6 DESCRIPTION... 6 APPLICATION NOTES... 7 VAX SITE CONTROLLER COMPUTER... 7 APPLICATION SOFTWARE

More information

Atrie WireSpan 600/610 MODEM User's Manual

Atrie WireSpan 600/610 MODEM User's Manual Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450 Trio Q Data Radios Licensed UHF Ethernet and Serial Data QR450 1 The Trio Q Data Radios are advanced high speed licensed digital data radios, which provide both Ethernet and serial communications for the

More information

TELECOMMUNICATIONS. Y-Packet R2 Y-Trunk farlink

TELECOMMUNICATIONS. Y-Packet R2 Y-Trunk farlink TELECOMMUNICATIONS Y-Trunk farlink > 20 000 microwave radio have been produced for last 10 years > 100 international partners > 50 countries all over the world receive Micran's products About Our Company

More information

SV613 USB Interface Wireless Module SV613

SV613 USB Interface Wireless Module SV613 USB Interface Wireless Module SV613 1. Description SV613 is highly-integrated RF module, which adopts high performance Si4432 from Silicon Labs. It comes with USB Interface. SV613 has high sensitivity

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

DSP40. User Manual.

DSP40. User Manual. DSP40 User Manual www.audac.eu ADDITIONAL INFORMATION This manual is put together with much care, and is as complete as could be on the publication date. However, updates on the specifications, functionality

More information

RF Components Product Catalogue

RF Components Product Catalogue RF Components Product Catalogue Government and Defence Broadcast Marine, Oil and Gas SNG and VSAT RF Engineering by Design Contents Splitters / Combiners Active Splitters and Combiners Page 3 Passive Splitters

More information

Technical Reference Manual

Technical Reference Manual Technical Reference Manual Technical Reference Manual Information in this manual is subject to change without notice. No part of this publication may be reproduced or distributed in any form or by any

More information

Single Elements for High Capacity Microwave Systems. Full and Half Duplex, 155/310/620Mbps, Split Mount or Full Indoor

Single Elements for High Capacity Microwave Systems. Full and Half Duplex, 155/310/620Mbps, Split Mount or Full Indoor Single Elements 48 Single Elements for High Capacity Microwave Systems Full and Half Duplex, 155/310/620Mbps, Split Mount or Full Indoor 49 FOR HIGH CAPACITY MICROWAVE SYSTEMS SDIDU - DRS Software Defined

More information

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1

ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1 ASTi SYNAPSE Remote Control Guide Document: DOC-01-SYN-RC-1 Advanced Simulation Technology inc. 500A Huntmar Park Drive, Herndon, Virginia, 20170 USA Revision B (Oct., 2011) Product Name: ASTi Synapse

More information

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide JOINT STOCK COMPANY MULTICHANNEL RECEIVER RI-4010M (version RM1-60619) User guide Safety requirements Before using the multichannel receiver RI-4010M read this user guide and follows safety requirements!

More information

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum. The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum. L3 (L3 T&RF) DR-2000 receiving unit incorporates a high-performance

More information

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,

More information

Ordering Guide - Tsunami GX800

Ordering Guide - Tsunami GX800 2011 2010 All rights reserved. Proxim Wireless Corporation. 1 Contents Purpose and Scope Product Description Ordering the Tsunami GX800 Microwave link Part 1 - Tsunami GX800 IDU Indoor Unit (IDU) IDU Mounting

More information

2W UHF MHz Radio Transceiver

2W UHF MHz Radio Transceiver 2W UHF410-470 MHz Radio Transceiver Specification Copyright Javad Navigation Systems, Inc. February, 2006 All contents in this document are copyrighted by JNS. All rights reserved. The information contained

More information

CM /100/1000BASE-T

CM /100/1000BASE-T Lantech CM-121 10/100/1000BASE-T to 1000BASE-X Standalone Managed Media Converter User s Guide Version 0.94 Trademarks Contents subject to revision without prior notice. All trademarks remain the property

More information

DXR 200 migration. 4RF White Paper. Contents. July 2012, issue 1.2.0

DXR 200 migration. 4RF White Paper. Contents. July 2012, issue 1.2.0 July 2012, issue 1.2.0 4RF White Paper DXR 200 migration Contents 1. Introduction 2 2. Aprisa XE industries and applications 3 3. Aprisa XE performance enhancements 4 4. Why choose 4RF Communications?

More information

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

1.0 Introduction. Related Products and Documentation

1.0 Introduction. Related Products and Documentation Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.

More information

Catalog

Catalog - 1 - Catalog 1. Overview... - 3-2. Feature...- 3-3. Application... - 3-4. Block Diagram... - 3-5. Electrical Characteristics...- 4-6. Operation...- 4-1) Power on Reset... - 4-2) Sleep mode...- 4-3) Working

More information

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6734 RS-232 Optical Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem (OTR) in

More information

Stat-4 Stat-8 Stat-24

Stat-4 Stat-8 Stat-24 JULY 1993 MX864A MX866A MX868A Stat-4 Stat-8 Stat-24 STAT-4 POWER MAIN 1 2 3 4 SYNC ERR OVF TEST 1 2 3 4 RESET STAT-24 STAT-8 POWER MAIN 1 2 3 4 5 6 7 8 SYNC ERR OVF TEST 1 2 3 4 5 6 7 8 TEST SYNC 23 24

More information

VSAT Redundant System Solutions

VSAT Redundant System Solutions DESCRIPTION The Paradise Datacom family of VSAT products can be configured in a variety of custom systems to meet any redundant system application. VSAT redundant systems can be configured to meet any

More information

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

AcuMesh Wireless RS485 Network. User's Manual SOLUTION AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the

More information

Copyright 1996 Codan Pty Ltd.

Copyright 1996 Codan Pty Ltd. No part of this handbook may be reproduced, transcribed, translated into any language or transmitted in any form whatsoever without the prior written consent of Codan Pty Ltd. Copyright 1996 Codan Pty

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice MEGAPLEX-2100 MODULE VC-1A 1-Channel PCM/ADPCM Voice Module Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications No part of this publication

More information

DRAFT. The MSS incorporates the base band processing, tributaries interfaces, radio port interfaces and supervision. The MSS is frequency independent.

DRAFT. The MSS incorporates the base band processing, tributaries interfaces, radio port interfaces and supervision. The MSS is frequency independent. 8 Functional operation 8.1 Microwave service switch (MSS) Microwave Service Switch (MSS) shelves provides up to 16 Gb/s packet switch node. The MSS incorporates the base band processing, tributaries interfaces,

More information

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1586-06 RF Attenuator May 2009 Rev A 1 2 3 12.5 53.5 16.3 MODEL 1586 RF ATTENUATOR CROSS TECHNOLOGIES INC. EXECUTE PS1 PS2 Data, drawings, and other material contained herein are

More information

Installation & Service Manual

Installation & Service Manual 869-894 MHz Installation & Service Manual Model SCA 9321-30C Single-Channel Cellular Amplifier 044-xxxxx Rev.A February 2003 2003 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies,

More information

Specification 6L,6H GHz 7,8 GHz 11 GHz 13 GHz 15 GHz 18 GHz

Specification 6L,6H GHz 7,8 GHz 11 GHz 13 GHz 15 GHz 18 GHz System Specifications Technical Introducing FibeAir IP-10 FibeAir IP-10 is Ceragon s next generation carrier-grade wireless Ethernet backhaul product family. Combining advanced TDM and Ethernet networking,

More information

IRT Eurocard. Type DAC AES / 2Mb (E1) G.703 Network Interface Adapter

IRT Eurocard. Type DAC AES / 2Mb (E1) G.703 Network Interface Adapter I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:

More information

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 1. Description. Furnish and install spread spectrum radio system. 2. Materials. Supply complete manufacturer specifications

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW2400iTR Indoor Wireless Ethernet

More information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor 1993 Specifications CSJ 0008-12-071 SPECIAL SPECIFICATION ITEM 6550 Drop/Insert Multiplexor/Demultiplexor 1.0 Description. This Item shall govern for the furnishing and installation of intelligent drop/insert

More information

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.02 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

OM1006 Solid State 50 MHz Power Amplifier

OM1006 Solid State 50 MHz Power Amplifier Instruction Manual OM1006 Solid State 50 MHz Power Amplifier OM POWER, s. r. o. 930 30 Báč 126 SLOVAKIA E-mail: om-power@om-power.com TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1. Introduction.. 4 1.2.

More information

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex Trio Q Licensed UHF Ethernet and Serial data radio QH450 Hot Standby Full Duplex 1 Trio Q Data Radios are advanced, high-speed licensed digital data radios, providing both Ethernet and serial communications

More information

Normalized. NE management by software application. Counters thresholds

Normalized. NE management by software application. Counters thresholds NE management by software application Figure 154: Qos ethernet counter period duration Normalized The MPR-e supports normalized Hop PM for both 1+0 and 1+1 HSB configuration in Single NE mode with 7705

More information

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex Trio Q Licensed UHF Ethernet and Serial data radio QB450 Full Duplex 1 Trio Q Data Radios are advanced, high-speed licensed digital data radios, providing both Ethernet and serial communications for complex

More information

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E

More information

TELECOMMUNICATIONS. Y-Packet Y-Trunk Y-Split Y-Haul

TELECOMMUNICATIONS. Y-Packet Y-Trunk Y-Split Y-Haul TELECOMMUNICATIONS Y-Packet Y-Trunk Y-Split Y-Haul > 20 000 microwave radios have been produced for last 10 years > 100 international partners > 50 countries all over the world receive Micran's products

More information

PI-10 Broadband Power Indicator

PI-10 Broadband Power Indicator PI-10 Broadband Power Indicator HIGH RF VOLTAGES MAY BE PRESENT AT THE PORTS OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with

More information

System Specification. BreezeACCESS TM EZ. January 2008

System Specification. BreezeACCESS TM EZ. January 2008 System Specification BreezeACCESS TM EZ January 2008 All rights reserved Alvarion Ltd 2008 The information contained in this document is the proprietary and exclusive property of Alvarion Ltd. except as

More information

TELECOMMUNICATIONS. Y-Trunk Y-packet R2 Y-packet R1 Y-packet 80 farlink

TELECOMMUNICATIONS. Y-Trunk Y-packet R2 Y-packet R1 Y-packet 80 farlink TELECOMMUNICATIONS Y-packet R1 Y-packet 80 farlink GAME IS NOT OVER Game is not over yet for microwave PtP in mobile operator s network. Network configuration changes quickly, sometimes intentionally,

More information

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL-0040-01 USER MANUAL The QP-FSPLL-0040-01 is a low-phase noise wideband synthesizer operating from 50 MHz to 40 GHz with a nominal output power of +15 dbm. The synthesizer

More information

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

Alcatel-Lucent MDR G H z F E D E R A L D I G I T A L R A D I O S

Alcatel-Lucent MDR G H z F E D E R A L D I G I T A L R A D I O S Alcatel-Lucent MDR-8000 2 G H z F E D E R A L D I G I T A L R A D I O S O V E R V I E W The MDR-8X02 is Alcatel-Lucent s premier digital microwave radio for long-haul, point-to-point wireless communications.

More information

Studio Broadcast System

Studio Broadcast System SET UP and USE 1. REGULATORY AND COMPLIANCE STATEMENTS... 3 2. OVERVIEW 2.1 Core Performance Targets 2.2 Specifications 2.3 System Components 2.4 System Block Diagram 3. BP24 UWB BODY PACK TRANSMITTER...

More information

NXE1 Digital Radio Link

NXE1 Digital Radio Link NXE1 Digital Radio Link A The Ultimate Digital Transmission System RARELY DOES TECHNOLOGY HAVE THE POWER TO DELIVER SUCH DIVIDENDS A Spectrum-Scalable Programmable Spectral Efficiency Unparalleled Robustness

More information

GPSR400 Quick Start Guide

GPSR400 Quick Start Guide GPSR400 Quick Start Guide Rev. 6 Introduction Microlab s digital GPS repeater system can be used for cellular communications UTC synchronization for locations where the GPS signals are not readily available.

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title Appendices 1 (10) Project designation R5 RIC Document title CONTENTS 1 Installation... 2 1.1 Connectors... 2 1.1.1 Power... 2 1.1.2 Video... 2 1.1.3 Sync... 3 1.1.4 RS232/ARP/ACP... 3 1.1.5 Radar data...

More information

SMARTALPHA RF TRANSCEIVER

SMARTALPHA RF TRANSCEIVER SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design

More information

WIRELESS MODBUS GATEWAY WGW410

WIRELESS MODBUS GATEWAY WGW410 WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their

More information

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series < Features > * GaN Technology Amplifier Inside * RF Frequency Line-up Universal Ku-band: 13.75 to 14.5 GHz Standard Ku-band: 14.0 to 14.5 GHz * High Efficiency Output Power Saturation Output Power: +46.0

More information

Redundant LNA Systems

Redundant LNA Systems < 1:1 LNA Plate Assembly with RCP2-1100 LNA PLATE Compact plate assemblies facilitate convenient antenna hub mounting Standard feed orientations State-of-the-art noise temperatures provided by Paradise

More information

Instruction Manual Model Block Translator

Instruction Manual Model Block Translator Instruction Manual Model 2083-21-1422 Block Translator October 2018, Rev. 0 1385>2230 G=20 TRX=846.001010 MHz MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings,

More information

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product

More information

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual Revision G Copyright 2017 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com E031130243 PROPRIETARY DATA All data

More information

Product Specification. 10Gb/s DWDM 80km XFP Optical Transceiver FTRX xx

Product Specification. 10Gb/s DWDM 80km XFP Optical Transceiver FTRX xx Product Specification 10Gb/s DWDM 80km XFP Optical Transceiver FTRX-3811-3xx PRODUCT FEATURES Supports 9.95Gb/s to 10.7Gb/s bit rates Hot-pluggable XFP footprint Maximum link length of 80km Temperature-stabilized

More information

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

MC450/MC650 (MC750) OPERATING INSTRUCTIONS MC450/MC650 (MC750) OPERATING INSTRUCTIONS MC 2 AUDIO Ltd., Units 6 & 7 Kingsgate, Heathpark Industrial Estate, HONITON, Devon EX14 1YG England Tel: ++(0)1404.44633 Fax: ++(0)1404.44660 www.mc2-audio.co.uk

More information

MBD-8F Automatic Antenna Switch Controller

MBD-8F Automatic Antenna Switch Controller - 1 - MBD-8F Automatic Antenna Switch Controller MBD-8F is an intelligent controller compatible with all eight-antenna switches manufactured by Hamplus. It has a band decoder to receive the information

More information

Alcatel-Lucent MDR / 1 1 G H z D I G I T A L R A D I O S

Alcatel-Lucent MDR / 1 1 G H z D I G I T A L R A D I O S Alcatel-Lucent MDR-8000 1 0. 5 / 1 1 G H z D I G I T A L R A D I O S O V E R V I E W The MDR-8X11 is Alcatel-Lucent s premier digital microwave radio for medium- and long-haul, point-to-point wireless

More information

RADWIN 2000 Portfolio. Built for Backhaul

RADWIN 2000 Portfolio. Built for Backhaul RADWIN 2000 cellular backhaul deployment RADWIN 2000 Portfolio Built for Backhaul The RADWIN 2000 portfolio of carrier-class sub-6 GHz products delivers ultra-capacity for long-ranges. Built for Backhaul,

More information

Phase Combined Systems

Phase Combined Systems 100W Ku-Band 1:2 Phase Combined SSPA System with FPRC-1200 Controller 1 kw C-Band, 1:1 Phase Combined High Power Outdoor SSPA System FEATURES 125W Ku-Band 1:1 Phase Combined SSPB System with FPRC-1100

More information

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series] Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series] Document Part Number: IM-T5218 Revision: 00 Issue Date: June 15, 2012 Copyright 2012, New Japan Radio Co., Ltd. All rights reserved. This

More information

Instruction Manual Model Ka-Band Block Upconverter

Instruction Manual Model Ka-Band Block Upconverter Instruction Manual Model 4115-300 Ka-Band Block Upconverter Weather Resistant Unit November 2015, Rev. H Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,

More information

SFT DAB. DAB Transmitters up to 15 kw rms.

SFT DAB. DAB Transmitters up to 15 kw rms. SFT DAB Series DAB Transmitters up to 15 kw rms www.screen.it Screen is a world-renowned company focused on turn-key and end-to-end solutions for all broadcasting needs. With more than 28 years of experience,

More information

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual IDA 4 XM V 1.X Installation and configuration of IDA 4 XM User Manual IMPORTANT SAFETY INSTRUCTIONS - Switch the device s power off before any maintenance operation (changing the CU card, etc.) - The 24V

More information

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation

More information

S O P H I S T I C A T E D A U T O M A T I O N

S O P H I S T I C A T E D A U T O M A T I O N S O P H I S T I C A T E D A U T O M A T I O N Introduction Cost-effective Radio modems to any serial communication application Low power models, different frequency ranges RS232 / / RS422 / 5V TTL interface

More information