Product Catalog ISO9001:2008 CE ROTARY ENCODER TEMPERATURE SENSOR TEMPERATURE CONTROLLER SOLID STATE RELAY
|
|
- Joy Page
- 5 years ago
- Views:
Transcription
1 MAXWELL Product Catalog ISO9001:2008 CE MS-1DA TEMPERATURE CONTROLLER SOLID STATE RELAY MS-1AA MS-3DA Heatsink ROTARY ENCODER TEMPERATURE SENSOR PROXIMITY SENSOR CAPACITIE SENSOR Tel: Fax:
2 Single Phase Solid State Relay MS-1DA Series MS-1AA Series A wide range of models with 10 to 120A output currents Maximum load capacity is 660AC 1:Basic Model Nmae 2:Rated Load oltage 48: 480AC 66: 660AC MS-1AA 1:Basic Model Nmae MS-1AA: Maxwell 1 phase SSR(AC to AC type) 2:Rated Load oltage 48: 480AC 66: 660AC DC to AC type AC to AC type MS-1AA4840:single phase AC to AC SSR(40A load 480AC) 5-32DC 480/ DC 3-15mA DC 8mA 0.1KG 480/660 90~280AC 3-12mA DC 8mA 0.1KG 480AC 2
3 Single Phase Solid State Relay MS-DD Series A Wide Range of models with 10 to 120A Output currents and Up to 480DC output oltages All models with the same universal standard size Operation indicator(red ) enables monitoring operation Protective cover for greater safety DC input and DC output Fast response and robust No noise during the operation Mosfet output Ordering Information(60 DC Load type) MS-DD MS-DD: 2:Rated Load oltage 60: 60DC 100 : 100A 120 : 120A Maxwell 1 phase SSR(DC to DC type) Ordering Information(110/220/480 DC Load type) MS-DD MS-DD: 2:Rated Load oltage 110 : 110DC 220 : 220DC 480 : 480DC Maxwell 1 phase SSR(DC to DC type) DC to DC type MS-DD6010: DC to DC SSR(10A load 60DC) 100: 100A 120 : 120A MS-DD11010: DC to DC SSR(10A load 110DC) Specifications(60DC Load type) Wiring and Dimensions 43mm Load oltage Control oltage Control Current On oltage Drop Off-leakage Current On-off Time Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight mm 28mm mm 25mm 3 2 Input Load 57.4mm 5-32 DC 5-50mA DC 60DC 1.5 2mA 10mS 2000 AC 500M /500DC C~+75 C Chassis Mount Specifications(110/240/480DC Load type) Load oltage Control oltage Control Current On oltage Drop Off-leakage Current On-off Time Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight ~32DC 110DC / 220DC / 480DC Control Circuit 0.1KG 5-32 DC 5-25mA DC 2.3 2mA 10mS 2000 AC 500M /500DC C~+75 C Chassis Mount 0.1KG Output Circuit 21mm mm Load 5-60DC 5-110DC DC DC _ + 3
4 Three Phase Solid State Relay MS-3DA Series MS-3AA Series A Wide Range of models with 10 to 200A Output currents Up to 1200AC output oltages All models with the same universal standard size Operation indicator(red ) enables monitoring operation Protective cover for greater safety Built-in RC Snubber Fast response and robust Zero cross function No noise during the operation Ordering Information(DC control AC type) MS-3DA DC to AC type AC to AC type MS-3DA: Maxwell 3 phase SSR(DC to AC type) 2:Rated Load oltage 38: 380AC 48: 480AC 66: 660AC 120: 1200AC 100: 100A 120: 120A 150: 150A 200: 200A MS-3DA3825: Three phase DC to AC SSR(25A load 380AC) Ordering Information(AC control AC type) MS-3AA MS-3AA: Maxwell 3 phase SSR(AC to AC type) 2:Rated Load oltage 38: 380AC 48: 480AC 66: 660AC 120: 1200AC 100: 100A 120: 120A 150: 150A 200: 200A MS-3AA3825: Three phase AC to AC SSR(25A load 380AC) 380 / 480 / 660 / DC 90~280AC DC Control:5-32DC AC Control:90~280AC Remark: There is no polarity for AC load side 4
5 Single Phase Power Regulator MS-1D Series MS-1R Series A Wide Range of models with 10 to 120Amps 220AC load or 380AC load Analog input/potentiometer input All models with the same universal standard size Operation indicator(red ) enables monitoring operation Protective cover for greater safety Resistance input or oltage input Fast response and robust No noise during the operation Ordering Information(Resistance input) MS-1R MS-1R: Maxwell oltage Regulator, potentiometer control 2:Rated Load oltage 38: 380AC Load 100 : 100A 120 : 120A Ordering Information(Analog input) MS-1D MS-1D: Maxwell oltage Regulator analog input 2:Rated Load oltage 22: 220AC Load 38: 380AC Load 100 : 100A 120 : 120A 4:Input Signal B: 0-10DC C: 4-20mA 4 Analog input Potentiometer Control Specifications(Potentiometer input) Load oltage Control Control Current On oltage Drop Off-leakage Current On-off Time Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight Specifications(Analog Input type) Wiring and Dimensions 43mm Load oltage Control oltage Control Current On oltage Drop Off-leakage Current On-off Time Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight 44.8mm 28mm mm Specification of MS serials SSR are subject to change without prior notice mm 3 2 Input Load 57.4mm 380AC 0-470Kü (220AC) 0-560Kü (380AC) 4-20mA _ N/A 1.5 2mA 2500 AC 100M /500DC C~+75C Input Control N/A 0.1kg 220AC / 380AC 4-20mA/0-10DC DC 4-20mA/0-10DC 1.5 2mA 10mS 2000 AC 500Mü /500DC C~+75C 0.1kg Phase control circuit 57.4L * 44.8W * 28H 21mm mm Load 220AC ~ ~ 5
6 Single Phase High Precision Power Regulator MS-1D--P Series A Wide Range of models with 10 to 400Amps 220AC load or 380AC load Analog input(0-10dc,4-20ma,0-5dc) All models with the same universal standard size Operation indicator(red ) enables monitoring operation Good precision, support multiple inputs Built-in buffer, to protect SCR against surge amps Input section and output section isolated No noise during the operation Ordering Information MS-1D MS-1D: Maxwell oltage Regulator 2:Rated Load oltage 22: 220A 38: 380A 100 : 100A 120 : 120A 200 : 200A 300 : 300A 400 : 400A 4:ersion Code P 4 P: For P series voltage regulator Specifications Load oltage Control Control Control Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight 220AC / 380AC 0-10DC Rated( 1.8DC -9.8DC) 0-5DC Rated( 0.8DC -4.6DC) 4-20mA DC Rated( 5.5mA -19mA) 2500 AC 100M /500DC C~+75C 0.38kg High precision Works with multiple inputs Connection Diagram 4 MAXWELL Caution and Warnings Specification of MS serials SSR are subject to change without prior notice +5DC CON COM mA DC oltage between 1 and 2 must have the same phase as voltage between 3 and 4 Remark: Terminal 7 for COM. negative for input signal Terminal 8 for 0-10DC input, positive terminals Terminal 9 for 4-20mA input, positive terminal Terminal 6 for 0-5DC input, positive terminal Terminal 5 is +5DC aux power, power source for potentiometer manual control 1.Appropriate heatsink must be used together with the unit 2.All terminals must be fasten tightly otherwise heat will accumulated on terminals 3.Cooling fans must be included when amps larger than 20amps and ambient temp higher 40C. 4.oltage between load(terminal 1 and 2) must have the same phase as voltage between terminal 3 and 4. 5.Always make sure a correct wiring to enable a appropriate control 6
7 Three Phase Power Regulator MS3-D Series MS-3DA/AA Serials Linear phase-shift control, excellent stability, high precision Modularized design, safer and reliable Small size, easy to install and wiring acuum welding technology, good quality and robust. Rated voltage: Three phase 380AC(four wires) Rated voltage for cooling fans: 220AC Rated amps: 10A/25A/40A/60A/80A/100A/120A Frequency: 50/60HZ Control signal: 4-20mA, 0-5DC, 0-10DC. Ambient temperature: Maximum temperature 47C Maximum humidity 90%RH Ordering Information MS3 4 Ms3: Maxwell Three Phase Power Regulator 2:Control Type D: Specifications Rated voltage Rated current Operation frequency Output mode Control signal Ambient Linear Control 3:Rated Load oltage 38: 380AC 4:Rated Load Current MS3-D3825A: Three phase power regulator 25A with control signal as 0-5DC Cooling fans 0 60: 40A 100: 100A 120: 120A 5:Control Signal A: 0-5DC input B: 0-10DC input C: 4-20mA input 380AC 10A/25A/40A/60A/80A/100A/120A 50/60HZ Phase output 4-20mA 0-5DC 0-10DC 0 Maximum temperature 47C/Maximum humidity 90%RH 220AC Basic Type Analog Control Wiring Diagram Dimensions L W A B A1 B1 C1 Input Output A2 B2 C2 LR1 LR2 LR3 B A N +5 CON COM Warning and Precautions(very important) A B C N Three phase 380AC Control signal Installation dimensions: W(90mm)*L(80mm) Overall dimensions: W(100mm)*L(110mm)*H(145mm) 1:The main circuit adopts three-phase four wire input without requirement for phase sequence 2:SCR with high amps of current flow through, be sure to tighten the terminal (A1 B1 C1 and A2 B2 C2) at its maximum extend. otherwise SCR might be damaged by heat generated around the terminals. 3:When Y connection used for load, the center of Y should be connected with zero line, otherwise, relative equilibrium of the three phase is required 4:When load greater than 15KW, Heatsink is a must for the SCR, and heat conducting silicon grease should be applied between chassis of SCR and the heatsink, and cooling fan is a must for the heatsink 5:Make sure to use semi-conductive fast fuse for overload protection 6:Make sure to pick proper heatsinks when load more than 15KW 7
8 Three Phase SCR Power Regulator TC Series A wide range of models with up to 250 amps output currents Work with 220AC and 380AC main source arious input signal, input field configurable, easy to use arious indications for input, output, and error for easy monitoring Over temperature protection, output terminated once over temp occurs Maximum and minimum output configurable Built-in buffer module, unit protected against surge amps Great linearity, strong anti-interference ability Multiple wiring arrangement, offer various control possibilities Heater break alarm optional Built-in maximum and minimum output tuning switch TC 4 1:Basic Model Nmae TC: Maxwell TC Series Power Regulator 2:(power supply for SCR itself) 1: 110AC 2: 220AC 4: 380AC 3:Main Controlled Source 2: 4: Item Nubmer 220~240AC 340~380AC Rated Current(Amps) High Precision and Robust 4:Main Controlled Current 100: 100 amps 125: 125 amps 150: 150 amps 180: 180 amps 200: 200 amps 250: 250 amps TC :TC SCR units, 220 aux power, 380 main controlled source, 180 amps Input Signal Configuration Installation Applicable Overall Dimension(mm) Dimension(mm) Weight(kg) Power(KW) Length Width Height Length Width TC TC TC TC TC TC This SCR supports 0-5DC,0-10DC,4-20mA DC input just put the jumper at respective position, the input signal can be changed. 0-10DC: Put the P1 jumper at S3 spot Phase shift control 0-5DC: Put the P1 jumper at S2 spot 4-20mA : Put the P1 jumper at S1 spot 20% output Factory default input is 4-20mA 50% output 90% output Cooling Fans cooling Panel Description Dry contact oltage Input signal A1 A2 M Aux Supply Input Signal DC+5 Potentiometer mA/ K 8 Wiring details :Main Controlled source 2: Aux power supply 3:Input signal labeling 4: rated amps labeling 5:arisou indicator POWER: Aux power feed indicator IN: Input signal indicator OUT: SCR output indicator ERR: SCR over temperature indicator 6:Output lowest limit tuning switch 7:Output highest limit tuning switch 8:Terminal arrangements labeling There are different ways to wire the SCR for different application, please check carefully on this part before using (1) Analog input( ma, m), and output ratio external adjustable, for example, can manually adjust the output from 0%~100% Input signal >Output ratio external adjustable(0%-100%) >The output ratio will always be 100% When short circuit E3 and E2 (2) Dry contact input, and output ratio external adjustable, for example, can manually adjust the output from 0%~100% >Output ratio external adjustable(0%-100%) >The output ratio will always be 100% When short circuit E3 and E2 8
9 (3) Analog input( ma, m), manual/auto control switchable, output ratio external adjustable, this wiring pretty much the same as type (1) the difference is the manual/auto control is switchable in this mode Input signal (4) Analog input( ma, m), Minimum output ratio can be pre-determined regardless of the input signal, even if input signal is 0 the SCR output will be restrained at its preset value. Input signal Minimum output adjust (5) Analog input( ma, m), Minimum and maximum output ratio can be restrained within a range. The SCR output will not response to input signals if input signals drives the output out of the preset ranges The SCR will work within a range for example 30%~80% Input signal Max. output adjust Min. output adjust When maximum and minimum output set as the same value. SCR output be fixed, and will not respond to the input signal (6) Analog input( ma, m), several SCR units connected together, with one of the units output ration adjustable(0%-100%) Input signal (7) Analog input( ma, m), several SCR units connected together, with one of at 4-20mA input, other units 1-5DC input, maximum 4 SCR units can be connected, all units output ration adjustable (8) Analog input( ma, m), serial connect 2 SCR units together, 2 SCR units controlled by same signals maximum 2 SCR units can be connected, all units output ration adjustable Cautions Input signal 1)For safety, must install a circuit breaks between the SCR and load 2)SCR can not be activated if the load disconnect or current less than 0.5 amps 3)A lot of heat will be generated during the operation. ambient temperature shall be less than 50C,if the cooling is not sufficient and ambient temperature larger than 60C, must use fans to cool the surroundings. 4)SCR operating with very high current, please make sure to fasten the screw firmly. or heat will be generated on the terminals and terminals will be damaged Dimensions and Mounting Cooling Fans Item Specs Units 9
10 < General Features Rated load voltage 380AC~440AC Power supply 220AC oltage input signal: 0-5DC,0-10DC,1-5DC,2-10DC Current input signal: 4-20mA,0-20mA,0-10mA Rated load current 40A, 60A, 75A, 100A. For resistive load Unique Features 3 phase input, auto phase detect Soft start function to protect load and SCR against surge current Integrated display with various indicator for status and error dispaly Integrated heatsink with auto temperature detection with over temperature alarm, SCR output reduce to preset value after alarm on(except T51). Maximum and minimum output configurable Maximum and minimum output configurable Auto/manual control switch RS-485 Mod Bus RTU communication optional(except T-51) Input event function Cautions!!! * SCR can not be operated without load or load current less than 0.5 * Please make sure to tighten the screw securely while wiring the SCR, otherwise extra heat will be accumulated on the terminals results a damage on the SCR * SCR must be mounted vertically on a solid panel without any objects placed above or beneath the SCR to make sure a smooth air flow * If multiple SCR installed at the same control cabinet, the main principle is to make the air flow efficient among each unit * The temperature inside of the control cabinet must be lower than 55 celsius, otherwise a cooling fan must be installed * If two SCR installed paralleled the distance between the two units must be more than CM * It is user s responsibility to make sure your selection on the SCR is compatible with your application * For safety consideration, a circuit breaker must be installed between the load and SCR * Touch the input and output terminals have the same risk even if there is not current at some certain period while SCR is still working * Never ever try to replace the cooling fans when SCR is working * Make sure the load voltage compliance with the ratings of SCR * Always make sure the wiring goes to the correct negative and positive terminals Ordering Information T51/T-6/T-7 4 1:ersion Code T51: T51 series, simplified version with limited function with compare to T6 and T7 T6: T6 series, with more features T7: T7 is the same function as T6, just different size for different mounting space 2:Load type 3: 3 phase load 380AC~440AC 3:Load current 75: 75A 100: 100A( only available for T6) 4:Power Supply 220: 220AC 380: 380AC D: 12-24DC 5:Control signals 1: 0-10mA 2: 0-20mA 3: 4-20mA 7: 2-10DC 6:Alarm 4: 0-5DC 5: 0-10DC 6: 1-5DC M: With alarm and Relay output N: No alarm 7:Communication M: With RS-485 Mod bus RTU N: Without communication feature Panel Discription AL1 POW L1 L2 L3 OUT MAN COM SET STOP RUN A/M C % Connection Diagram INDICATOR SET KEY 3 Phase Power Power Supply AC 220 If you have a selection [ T M-N ] >T7 series >3 phase load >40 amps >220AC for SCR itself >Input 4-20mA >With alarm >Without communication OUT: The flashing frequency indicate the output ratio AL1: Over temperature alarm indicator POW: Power feed indicator L1: Phase indicator, when L1 absence, lights on L2: Phase indicator, when L2 absence, lights on L3: Phase indicator, when L3 absence, lights on MAN: Manual control indicator COM: Communication indicator SET: Parameter setting and configuraion A/M: Manual/auto control switch POW: Power feed indicator <: Left shift key, to shift the display unit < : Decrease key or Stop key : Increase key or Run key Fast fuse, rating at 1.5 x Load amps RS-485 AC1 AC2 B- A+ R S T 4-20mA NO COM NC CC IN- R(250 ohm) IN+ 250 Ohm resistor when input 4-20mA U W +5 NO NC LOAD COM Used with potentiometer DC 0-10mA/DC 0-20mA/DC 4-20mA (switchable between each other) DC 0-5/DC 0-10/DC 1-5/DC 1-10 (switchable between each other) 10
11 AC1 A C2 ON CO M OC B- A+ IN- IN- IN+ +5 A C F AC1 AC2 ON COM OC B- A+ IN+ +5 F2 FAN LINE R S LINE T WARNING U LOAD LOAD W OUT 1 2 SET AL1 OUT POW AL1 L1 POW OUT AL1 POW L1 L2 L3 MAN COM SET WARNING: 1 STOP Do not connect AC power to output terminal s Read the user manual before operation STOP L2 RUN L3 WARNING: Do not connect AC power to output terminals Read the user manual efore operation b L1 L2 L3 2 3/ RUN Power Regual t or MAN 3 / A/M A/M COM Power Regulator Size and Dimensions AC A C INPUT + - C % C Power Re gulator T SET % C % Model T N-N T N-N T N-N Model T N-N T N-N T N-N T N-N Model T N-N T N-N T N-N Size(mm)L*W*H Install(mm)L*W 118*140*118 55* *140* *140*118 55*135 55*135 Size(mm)L*W*H 160*140* *140* *140* *140*145 Size(mm)L*W*H 160*110* *110* *110*148 Install(mm)L*W 120* * * *130 Install(mm)L*W 105* * *100 11
12 MAXWELL Three Phase Reversing Solid State Relay MS-3M Series A Wide Range of models with 10 to 120A Output currents Up to 660AC output oltages All models with the same universal standard size Operation indicator(red ) enables monitoring operation Protective cover for greater safety Built-in RC Snubber Fast response and robust Zero cross function No noise during the operation Ordering Information(480 Load Type) MS-3M Section MS-3M: Maxwell 3 Reversing SSR Section 2:Rated Load oltage 48: 480AC MS-3M4825: Three phase reversing solid state relay 660 Load MS-3M Section MS-3M: Maxwell 3 Reversing SSR Section 2:Rated Load oltage 66: 660AC MS-3M6625: Three phase reversing solid state relay Section 100: 100A Section 100: 100A Specifications(480 Load) Load oltage Control oltage Control Current On oltage Drop Off-leakage Current Reversing time duration Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight Specifications(660 Load) Wiring and Dimensions 4.8 Load oltage Control oltage Control Current On oltage Drop Off-leakage Current On-off Time Dielectric Strength Insulation Resistance Ambient Temperature Mounting Indicator Weight / / R R C1 B1 A DC 10-30mA 2 10mA 300mS 2500 AC 1000M /500DC C~+75C (Red Green) 0.3KG DC 10-30mA 2 10mA 300mS 2500 AC 1000M /500DC C~+75C (Red Green) 0.3KG Rv Rv Corotation Reverse C2 B2 A M 33mm 12
13 MaxWell Accessories for SSR Heatsinks for SSR,SCR. Cooling Fans for SSR MS-3DA/AA Serials SSR and HeatSink Compatible checking list Ordering Information(For Single Phase SSR) MW-I HeatSink Unit:mm 80 60(L) 50(H) 60 (L) MW-I:Compatible with Single Phase SSR with load at 10A and 25A(60*50*50) MW-W-A HeatSink MW-W-B HeatSink Unit:mm (W) 48 50(H) 100(W) 0.2KG MW-W-A: Compatible with Single Phase SSR with load at 40A(72*100*50) MW-W-B: Compatible with Single Phase SSR with load at 60A(100*100*50) MW-T HeatSink 80(H) Unit:mm 70(W) 70 (W) Compatible SSR: Single Phase SSR with load at 80A/100A/120A.(80*70*80) iew from top MW-W-A 50(W) 100(L) 80 (L) HeatSinks and Fans ITEM NO SIZE Compatible SSR Remark MW-I 60x50x50 10A/25A Single Phase SSR MW-W-A 72x100x50 40A Single Phase SSR MW-W-B 100x100x50 60A Single Phase SSR MW-T 80x80x70 80A/100A/120A Single Phase SSR MW-L 150x88x35 10A/25A Three Phase SSR MW-H-A 110x80x80 40A Three Phase SSR MW-H-B 150x80x80 60A Three Phase SSR MW-Y-A 110x125x135 80A Three Phase SSR MW-Y-B 150x125x A/120A Three Phase SSR MW-Y-C 170x125x A/200A Three Phase SSR iew from top iew from top Unit Weight: 0.1KG 100(W) 0.3KG MW-W-B 72(L) Unit Weight: 0.4KG Ordering Information(For Three Phase SSR) MW-L HeatSink Compatible SSR: Three Phase SSR with load at 10A/25A.(150*88*35) MW-H-A HeatSink MW-H-B HeatSink (W) 0.5KG MW-H-A: Compatible with three phase SSR with load at 40A(110*80*80) MW-H-B: Compatible with three phase SSR with load at 60A(150*80*80) MW-Y-A HeatSink MW-Y-B HeatSink MW-Y-C HeatSink Unit:mm 125(W) 80 Unit:mm Unit:mm 135(H) 125(W)(1.5KG) 110(L) MW-Y-A:Compatible with three phase SSR with load at 80A(110*125*135) MW-Y-B:Compatible with three phase SSR with load at 100A/120A(150*125*135) MW-Y-C:Compatible with three phase SSR with load at 150A/200A(170*125*135) MF-1-B-8-110/220 MF-1-S-8-110/220 MF-1-B :Ball bearing Fans(110) Size:80mm*80mm, with Metal Protector MF-1-B :Ball bearing Fans(220) Size:80mm*80mm, with Metal Protector MF-1-S :Sleeve bearing Fans(110) Size:80mm*80mm, with Metal Protector MF-1-S :Sleeve bearing Fans(220) Size:80mm*80mm, with Metal Protector iew from the top 150(W) MW-H-A 110(L) 125(W)(1.9KG) 150(L) 88(L) iew from the top Unit Weight: 0.4KG 80(W) 0.8KG iew from the top MW-H-B 125(W)(2.3KG) 150(L) MW-Y-A MW-Y-B MW-Y-C MF-1-B /220 MF-1-S / (L) MF-1-B :Ball bearing Fans(110) Size:120mm*120mm, with Metal Protector MF-1-B :Ball bearing Fans(220) Size:120mm*120mm, with Metal Protector MF-1-S :Sleeve bearing Fans(110) Size:120mm*120mm, with Metal Protector MF-1-S :Sleeve bearing Fans(220) Size:120mm*120mm, with Metal Protector 13
14 ELECTRICAL LIMITED Add:NO.68 JianMeiLi Industrial Park, HaiCang district, XiaMen,FuJian, China Tel: Fax: In case we didn t get your , please send your inquiry to our alternative mail @qq.com Thank you very much
INSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS PRODUCTS CCM SERIES NOTE: This document provides the necessary information for the use and operation of Greystone current valves. Greystone Energy Systems Inc. reserves
More informationSHIMADEN THREE-PHASE POWER REGULATOR
SHIMADEN THREE-PHASE POWER REGULATOR SERIES PAC30Z Easy Wiring With 2-Phase Control Low-Noise Design Wide Capacity Selection (18~135A) Output Standard Feature SPECIFICATIONS Control input: Current capacity:
More information3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays
.6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationVF-nC1 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1
More informationZT-30 ZeroTEM TRANSMITTER MANUAL
ZT-30 ZeroTEM TRANSMITTER MANUAL 06 September, 2000 Zonge Engineering and Research Organization, Inc. 3322 East Fort Lowell Road, Tucson, AZ 85716 USA Tel:(520)327-5501 Fax:(520)325-1588 Email:zonge@zonge.com
More informationIC800SSD Hardware Manual Pub 348R5. for models. A publication of
IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A
More informationP o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.
P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched
More informationAnacon Power & Controls
2254 Main Street, Concord, MA 01742-3829 Tel: 800-466-9080 978-287-0715 Fax: 978-287-0952 www.anaconpower.com sales@anaconusa.com SCR Power Controllers Zero Cross Time Based / Burst Fire C - SCR (Burst)
More information3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3
More informationS11 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National
More informationE3 Adjustable Speed Drive Engineering Specification
E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National
More informationCONTENTS XV300K GB r doc XV300K 2/13
XV300K CONTENTS 1 PRELIMINARY CHECK GUARANTEE RECYCLING... 3 2 XV300K SPECIFICATIONS OF USE... 3 3 CODES - MODELS... 4 4 TECHNICAL SPECIFICATIONS... 4 5 STANDARD REFERENCES... 5 6 MECHANICAL INSTALLATION...
More informationAn RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.
The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial
More informationGTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL
GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL Main applications Plastics extrusion lines and injection moulding machines Polymerization plant for synthetic fibre production
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationTE200S Solid State Relays. Two-phase control of three-phase loads. User manual
TE200S Solid State Relays Two-phase control of three-phase loads User manual Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission in any form or using any procedure
More informationcelduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you
Power Solid State Relay With Analog Control, pitch.5mm compact size and DIN rail mounting. Ready to use SinglePhase Relay: Phase angle controller Transfer characterisic :Angle open loop Operating voltage
More informationRSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC
(reinforced isolation) SPECIFICATION MODEL OUTPUT INPUT PROTECTION RSD-30G-3.3 RSD-30G-5 RSD-30G-12 RSD-30G-24 RSD-30L-3.3 RSD-30L-5 RSD-30L-12 RSD-30L-24 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER
More informationSPECIFICATION, CONTROLS AND ACCESSORIES
AS440 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y697 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationOPERATOR S INSTRUCTION MANUAL
2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions
More informationHAWK5000 Operators Manual
HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED
More informationAnalogue temperature controllers
Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications
More informationEarth 2/3 MI 2126 Instruction Manual Version 1.0, Code No
Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No. 20 750 190 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: metrel@metrel.si
More information60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC
SPECIFICATION MODEL OUTPUT INPUT PROTECTION RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24 RSD-60L-3.3 RSD-60L-5 RSD-60L-12 RSD-60L-24 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER 3.3V 0 ~ 39.6W 5V
More informationP. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX
SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations
More information300W Railway Single Output DC-DC Converter
SPECIFICATION MODEL OUTPUT INPUT PROTECTION WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 4) OTHERS NOTE OVER OVER VOLTAGE SAFETY STANDARDS
More informationZHUHAI PILOT TECHNOLOGY CO., LTD.
SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.
More informationCCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault
CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...
More informationSHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual
SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable
More informationOPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM
OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationBuilt-in soft-start feature. Up-Slope and Down-Slope. Power-Up safe start feature. Motor will only start if pulse of 1.5ms is detected.
Thank You for purchasing our TRI-Mode programmable DC Motor Controller. Our DC Motor Controller is the most flexible controller you will find. It is user-programmable and covers most applications. This
More informationSERIES KC RELAY NONLATCH 3PDT, 25 AMP
All welded construction Contact arrangement 3 PDT configuration in one inch cube Qualified to MIL-PRF-83536 PRINCIPLE TECHNICAL CHARACTERISTICS Applicable sockets: SO-1057-8912 Contacts rated at 28 Vdc;
More informationcelduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you
AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting. Ready to use Single-Phase Relay: " Install it & Forget it!" Zero cross model : 7-28AC 5A back to back thyristors
More informationVC835 DIGTAL MULTIMETER Operation Manual
VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with
More informationSeries 7 Power Controllers
Series 7 DIN Rail Mount Power Devices Series 7 Power Devices put 12 to 80 Amps in a DIN rail mount package that provides precision machine control for heater bands, cartridge heaters, and other resistive
More informationcelduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you
Power Solid State Relay With Analog Control, pitch 22.5mm compact size and DIN rail mounting. Ready to use SinglePhase Relay: Phase angle controller Transfer characterisic :Angle open loop Operating voltage
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationJacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)
Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationMonitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55
Overview Application The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium,
More informationRAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL
RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External
More informationPOWER ANALYZER OPERATION MANUAL. Model : DW-6090A
POWER ANALYZER Model : DW-6090A Your purchase of this POWER ANALYZER marks a step forward for you into the field of precision measurement. Although this POWER ANALYZER is a complex and delicate instrument,
More information60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC
SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.2 60mVp-p 100mVp-p 50mVp-p 50mVp-p
More informationINSULATION TESTER SERIES
INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection guide IR4056-20
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationSECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)
ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX
More informationTRANSFORMERS CHASSIS TANSFORMERS FERRITE ROD 2328 LIGHTING TRANSFORMERS 2328 TOROIDAL TRANSFORMERS 2327 TRANSFORMERS
TRANSFORMERS PULSE TRANSFORMER DAVID USE PHOTO SD0010 AUDIO TRANSFORMER CHASSIS TRANSFORMER TOROIDAL TRANSFORMER LIGHTING TRANSFORMER DAVID USE PHOTO SD0010 CHASSIS TANSFORMERS 2325-2328 FERRITE ROD 2328
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationMM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging
More informationTable of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17
Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................
More informationTC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)
TC1028 series Thyristor units Control of single-phase resistive or inductive loads User manual (300A to 500A rated units) Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationAmbient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3
CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2
More informationAdvantages of the 70S2 Series
Advantages of the 70S2 Series Since acquiring this line of miniature SSRs from Grayhill, this product has continuously evolved both functionally and visually. The 70S2 Series relays are designed for medium-power
More informationCurrent Loop Interface Module M-2025C
CONTROLS Interface Module M-2025C Current-to-Voltage Analog Converter used with the M-2001 Series Digital Tapchanger Control and M-2948/M-2949 Tap Position Sensors to provide positive tap position knowledge
More informationMM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &
More informationLL-105-R LED Dimmer & 0-10V Bridge Setup Guide
www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.
More informationStatiVolt. Inverter UPS Systems. Features. Contents
Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built
More informationSX (400 V) System configuration
~ ~ SX (400 V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More information200W Railway Single Output DC-DC Converter 33.6 ~ 62.4VDC 28.8 ~ 67.2VDC
SPECIFICATION MODEL OUTPUT INPUT PROTECTION RSD0B12 RSD0B24 RSD0B48 RSD0C12 RSD0C24 RSD0C48 RSD0D12 RSD0D24 RSD0D48 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER 12V 16.7A 0 ~ 16.7A 0.4W 24V 8.4A
More informationUSER'S MANUAL DMR-4350
USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................
More informationET-3888 True RMS Clamp Meter. User Manual
ET-3888 True RMS Clamp Meter User Manual Index Introduction... 3 Safety Notes... 4 Features... 5 Specifications... 6-8 Instrument Layout... 9 Measurement... 10 Maintenance... 11 Page 2 1. Introduction
More informationsimulations that extend the test capability for the most demanding engineering and automated test applications.
Programmable DC Electronic Load MODEL 63200 SERES Key Features : Power Rating : PROGRAMMABLE DC ELECTRONC LOAD MODEL 63200 SERES Chroma's 63200 series of programmable electronic loads are designed to a
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More informationK3P ENG.qxd 23/10/ Pagina 1
K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED
More informationVFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions
ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Product availability : Stock - Normally stocked in distribution facility Price* : 191.76 USD Main Range of
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationDigital Clamp Meter. User Manual
Digital Clamp Meter User Manual CM240 WWW.OWON.COM.CN Mar. 2016 edition V1.2 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the patent rights, including
More informationInstruction Manual. Digital Panel Meter Model 3153B
Instruction Manual Digital Panel Meter I-01999 1. Preface Please take care that this instruction manual is certainly delivered to the person in charge of operating this instrument. For safe use of this
More informationPEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B
PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints
More informationMODEL SERIES MODEL SERIES. Programmable DC Electronic Load
Programmable DC Electronic Load MODEL 63200 SERES PROGRAMMABLE DC electronic load MODEL 63200 SERES The Chroma Electronic Loads 63200 series and Master / Slave control capability, the are designed for
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More informationElectronic Circuit Protector ESX10-T
Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationTo be automatically connected to the nearest North American Technical Sales Office:
DIN-A-MITE C SCR Power Controller Delivers Up To 80 Amperes in a Compact Package TOTAL CUSTOMER SATISFACTION 3 Year Warranty The Watlow DIN-A-MITE Style C silicon controlled rectifier (SCR) power controller
More informationAdvantages of the 70S2 Series
Advantages of the 70S2 Series SECTION Since acquiring this line of miniature SSRs from Grayhill, this product has continuously evolved both functionally and visually. The 70S2 Series relays are designed
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationCSG110 Strain Gauge Universal Amplifier
Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationINSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)
INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668) Use with Models KBDA-24D, 27D, 29, 45, 48 See Safety Warning, on page 4. RoHS The information contained in this
More information3 Input (+) & 4 Input (-) 1 & 2 Output
Product Catalogue DC SSR 02 ~ 40 Amps INPUT OUTPUT : DC Control, : Darlington/MOSFET Input Series : 001 K 3 Input (+) & 4 Input (-) 1 & 2 A = 3.2 C/W C = 0.5 C/W For Heatsink details refer to Recommended
More information3DM phase Digital Stepper Drive
3DM2283 3-phase Digital Stepper Drive 150-220VAC, 0.5-8.2A peak, Auto-configuration, Low Noise Anti-Resonance provides optimal torque and nulls mid-range instability Motor auto-identification and parameter
More informationBrunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2
Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing
More informationcelduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac
Power Solid State Relay With Analog Control, pitch 22.5mm compact size and DIN rail mounting. Ready to use Single-Phase Relay: Phase angle ler Transfer characterisic :Angle open loop Operating voltage
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationEC centrifugal fan. backward curved, single inlet
RG4-AM56- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 8 8- Fax: +49 8 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG4-AM56- MG-EA Phase ~ Nominal voltage [VAC]
More informationRHP-1U Rack System. 1600~8000W 1U Distributed Power/Charger System. File Name:RHP-1U RACK SYSTEM-SPEC Sicherheit ID
Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 600~8000W U Distributed Power/Charger System RHP-U Rack System File Name:RHP-U RACK SYSTEM-SPEC 06--09 600~8000W U Distributed
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationCI-tronic Soft start motor controller
Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationMM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS
INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY
More informationPower Resistor, for Mounting onto a Heatsink Thick Film Technology
Power Resistor, for Mounting onto a Heatsink Thick Film Technology FEATURES 5 W to 50 W High power rating DESIGN SUPPORT TOOLS Models Available click logo to get started High overload capabilities up to
More informationIndex 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13
Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access
More informationPEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION
The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety,
More informationADJUSTABLE SPEED DRIVES VF-S11 Sords Electric
ADJUSTABLE SPEED DRIVES VF-S11 The Next Generation of Micro Inverters is Here. The S11 provides maximum torque with precise speed control. It features an easy-to-use, quiet and compact design. In addition,
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More information