IntelliSAW CAM Platform Sensors INSTALLATION MANUAL. Document: Revision: 1.0. Date: 19 September, 2016.
|
|
- Eustace Gallagher
- 5 years ago
- Views:
Transcription
1 INSTALLATION MANUAL Document: Revision: 1.0 Date: 19 September, 2016 Page 1 of 33
2 Copyright 2016, IntelliSAW IntelliSAW reserves the right to make technical changes or modify the contents of this document without prior notice. IntelliSAW is not responsible for errors or possible lack of information in this document. IntelliSAW reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents, in whole or in part, without prior written consent of IntelliSAW is forbidden. IntelliSAW Rosemount Measurement Emerson Process Management 100 Burtt Rd. Andover, MA WARRANTY These products are warranted to be free from functional defects in material and workmanship at time of manufacture and to conform at that time to the specifications set forth in the relevant instruction manuals or data sheets, for such products for a period of one year. Reference IntelliSAW terms and conditions provided at time of purchase for complete warranty details. Installation Manual Page 2 of 33
3 IMPORTANT INFORMATION This symbol identifies messages in this document related to safety. DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. Failure to follow the instructions given will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. Failure to follow the instructions given can result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. Failure to follow these instructions can result in personal injury. NOTICE NOTICE alerts you to practices unrelated to personal injury, such as those that can cause property damage. Failure to follow these instructions can result in property damage. IMPORTANT IMPORTANT indicates additional information about making effective use of this product. Installation Manual Page 3 of 33
4 TABLE OF CONTENTS 1 Introducing the IntelliSAW CAM Platform Sensors IntelliSAW System Architecture SAW Temperature Sensors Specifications Dimension and Mounting Labeling Band Identification and Cal Code Grouping CAM Air Interfaces TMP Air Interface Temperature Only Specifications Dimensions TPD Air Interface Temperature and Partial Discharge Specifications Dimensions Labeling Front (digital print) Back Label Mounting Cabling Impact of Cable Length on Read Range Humidity & Ambient Temperature Sensor Specifications Dimensions Label Mounting Options Wiring Single Connection Series Connect Star Connect Installation Typical Installation Temperature Sensor / Air Interface Installation...22 Installation Manual Page 4 of 33
5 5.2.1 Required Hardware Basic Insulation Level (BIL) RF Isolation and Maximum Sensor Count Sensor Arrangements Mounting Temperature Sensors Radiation Patterns Air Interface Installation Optimizing Signal Strength & Configuring the System SAW Temperature Calibration Partial Discharge Configuration Humidity / Ambient Sensor Installation Mounting Humidity Sensor Wiring Outdoor Asset Installation with Environmental Enclosures...32 Contact...33 Installation Manual Page 5 of 33
6 1 INTRODUCING THE INTELLISAW CAM PLATFORM SENSORS The IntelliSAW Critical Asset Monitoring (CAM ) Platform monitors the three main failure modes of electrical power critical assets. A CAM system consists of a monitoring unit (CAM-4 or Reader) and three types of sensors: Wireless SAW Temperature: addresses thermal breakdown Partial Discharge: addresses insulation breakdown Humidity / Ambient Temperature: addresses air dielectric breakdown 1.1 INTELLISAW SYSTEM ARCHITECTURE IntelliSAW monitoring units (Reader or CAM-4) can accept the following MAXIMUM sensor configuration: 12 wireless SAW temperature sensors 4 air interfaces (Temp only or Temp & PD) 8 humidity / ambient temperature sensors (series connected) Figure 1: IntelliSAW System Overview Installation Manual Page 6 of 33
7 2 SAW TEMPERATURE SENSORS Wireless, passive Surface Acoustic Wave (SAW) temperature sensors are directly mounted to asset critical measurement locations. Radio Frequency (RF) interrogation signals between monitoring units / air interface and sensors are used to determine the temperature. 2.1 SPECIFICATIONS Temperature Measurements Range Resolution Accuracy Standard Range (0 to 80 C) Full Range Number of Sensor Channels Sensor Frequencies -25 C to +125 C ± 0.2 C ± 2 C ± 4 C 12 (non-overlapping channels) Between 425 MHz to 442MHz Physical Base Plate Material 260 Brass, Tin Plated Cover Material Polycarbonate, UL94-HB International Protection (IEC 60529) IP 30 Cover Dielectric Strength 15 KV Dimensions 30.5W x 53.5 L x 35.5 mm H Mounting Bolt (Max) Mounting Torque (Max) Alternate Solutions 13 mm or ANSI ½ in. 102 N-m (75 lb-ft) Use asset manufacturer s recommended bolt torque at all times. A high strength flat washer between the nut and the sensor must be used. Cable Tie: 5.5 W x 1.65 mm Thick (Max) Non-conducting ETFE, 150 C operating temperature (McMaster-Carr 70215K93) Bonding Tape 3M VHB 4646 Bonding Tape (150 C operating temperature) Type Testing Units were installed on switchgear critical locations while the switchgear was subjected to the following testing: IEC IEC MV Switchgear, Voltage withstand: 95 kv/1m, 185 kv impulse MV Switchgear, Short circuit withstand: 63 ka/3s, 171 ka impulse Installation Manual Page 7 of 33
8 2.2 DIMENSION AND MOUNTING SAW Temperature sensor dimensions are 30.5W x 53.5 L x 35.5 mm H. The recommended mounting method is to bolt mount with an existing asset bolt, although alternative mounting solutions such as heat resistant tie wraps or heat resistant tap can be used. For details on installation methods and specifications: 5.2 Temperature Sensor / Air Interface Installation 2.3 LABELING Figure 2: Temperature Sensor Dimensions SAW Temperature sensors have 4 types of labels (sensor ID, sensor ID with barcode, sensor serial number, and China RoHS) Serial Number China RoHS Sensor ID Figure 3: Sensor Labels (Sensor ID with barcode not shown) Band Identification and Cal Code The SAW Temperature sensors have 12 unique band numbers and are grouped by color codes to ensure optimal performance along with easy installation and visualization in electrical power Installation Manual Page 8 of 33
9 assets. They also contain a calibration letter which will be used during configuration. In the sensor example above, the identification would be Band: 08, Cal Code: N. The Band Identification and Cal Code are required when configuring a monitoring unit for temperature measurements. 2.4 GROUPING Sensors are grouped with unique color codes (Sensor ID Labels) to support easy installation and visualization in electrical power assets. When commissioning a system, care must be taken not to duplicate same sensor frequency bands within a given asset or in the common bus of adjacent assets. IntelliSAW recommends selecting sensors based on their groupings for optimal performance. The color codes may also be used as a short-hand notation in system single-line drawings to denote a group of sensors. Identification Bands Sensor Group Color 01, 03, 05 Orange 02, 04, 06 White 07, 09, 11 Dark Gray 08, 10, 12 Tan Figure 4: Example Labels Installation Manual Page 9 of 33
10 3 CAM AIR INTERFACES IntelliSAW Air Interfaces provide optimal signal performance for measuring passive SAW temperature sensors and detecting Partial Discharge (PD) with immunity from induced power frequencies. Reading distances compatible with basic insulation levels (BIL) up to 185kV. There are two CAM Air Interfaces models: TMP: used only for SAW temperature sensor interrogation TPD: used for SAW temperature sensor interrogation and PD monitoring The air interfaces are directly connected to a monitoring unit through shielded coaxial cable and are to be attached to earthed enclosure metal for safety. 3.1 TMP AIR INTERFACE TEMPERATURE ONLY Specifications General Specifications Span Return Loss Gain Impedance Dimensions Material Weight Mounting Interface Connector 425 MHz 442 MHz -7db maximum +3.0 dbi, typical 50 Ω, nominal 118 W x L x mm H (4.65 x 5.3 x 1.36 in.) ABS UL 94 V-0, black 0.2 kg (0.45 lb) Magnetic: 4 magnets, 32.6 kg (72 lb) pull force Bolt mount: 4 x 4.8 mm eyelets SMA International Protection (IEC 60529) IP 40 Operating Condition -25 C to + 70 C, 10 95% RH non-condensing Installation Manual Page 10 of 33
11 3.1.2 Dimensions The TMP Air Interface is 118 W x L x mm H (4.65 x 5.3 x 1.36 in.). Figure 5: TMP Dimensions 3.2 TPD AIR INTERFACE TEMPERATURE AND PARTIAL DISCHARGE The TPD Air Interface combines SAW temperature sensing and Partial Discharge detection. This broad band antenna is optimized for UHF radio detection methods at three distinct bands with center frequencies of 300 MHz, 600 MHz, and 1200 MHz while still providing capabilities for SAW sensor detection at 433 MHz. The CAM air interface affords multiple opportunities to recognize internal and surface discharges associated with the onset of critical asset insulation failures and to distinguish these events from noise sources. Installation Manual Page 11 of 33
12 3.2.1 Specifications General Specifications Span Return Loss (1) At 300 MHz (2) At 425 MHz (3) At 442 MHz (4) At 600 MHz (5) At 1200 MHz Gain Impedance Dimensions Material Weight Mounting 250 MHz 2 GHz See Figure 4 for details Reflective -16 db, max -10 db, max Reflective -16 3, max +3.5 dbi, typical 50 Ω, nominal 198 W x 167 L x 43 mm H (7.8 x 6.6 x 1.7 in.) ABS UL 94 V-0, black 0.57 kg (1.25 lb) Magnetic: 4 magnets, 50.8 kg (112 lb) pull force Bolt mount: 6 x 4.8 mm eyelets (magnets must be removed) Interface Connector SMA International Protection (IEC 60529) IP 40 Operating Condition -25 C to + 70 C, 10 95% RH non-condensing Installation Manual Page 12 of 33
13 3.2.2 Dimensions Figure 6: Air Interface Dimensions 3.3 LABELING Front (digital print) The front of each air interface provides the product logo (IntelliSAW), platform (Critical Asset Monitoring) device type (Air Interface) and application the units can be used for: Temperature Temperature and Partial Discharge Installation Manual Page 13 of 33
14 Figure 7: TPD and TMP Air Interfaces - Front print Back Label The back label contains the model number and serial number of the Air Interface. Model Number Serial Number Figure 8: Air Interface Back Label 3.4 MOUNTING All air interfaces use Neodymium rare-earth magnets, the strongest and most permanent magnets known to man. If they are not overheated or physically damaged, neodymium magnets lose less than 1% of their strength over a 10 year period and less than 5% over a typical asset lifetime. Magnets are the optimal solution for locating the air interface to ensure proper signal strength to the SAW sensors. After the final air interface location has been determined, the units can be bolt mounted if chosen. Installation Manual Page 14 of 33
15 3.5 CABLING IntelliSAW uses the highest quality double-shielded coaxial cables to ensure no signal degradation during data acquisition. The cables are assembled with the required SMA connectors to interface from an air interface to an IntelliSAW monitoring unit Impact of Cable Length on Read Range SAW passive wireless sensors are linear systems and the fundamental limitation for the SAWbased identification system occurs when the received signal level at the reader becomes too weak for reliable detection. With RF signals, as the cable length increases, read range decreases, and therefore there are cable length restrictions. The average loss of read range is 2% per meter. Available Lengths: 3m, 5m, 7m, and 10m Installation Manual Page 15 of 33
16 4 HUMIDITY & AMBIENT TEMPERATURE SENSOR The IntelliSAW Humidity Sensor provides real-time, continuous monitoring of relative humidity and ambient temperature to identify the potential for flashover. The sensor s sintered cap, threaded body, water resistant M12 connector, and 4kV surge protection provides the level of packaging robustness required for reliable operation in harsh environments. The IntelliSAW CAM platform allows up to 8 humidity sensors to be bussed together for multiple location installations such as along a bus duct. 4.1 SPECIFICATIONS Humidity Measurements Range Resolution Accuracy Standard Range (20 to 80%RH) Full Range Repeatability Long term drift 0 to 100% Relative Humidity (%RH) ± 0.1%RH ± 4.5%RH ± 7.5%RH ± 0.2%RH < 0.5%RH/yr Ambient Temperature Measurements Range -25 C to +120 C Resolution ± 0.1 C Accuracy ± 2.5 C Repeatability ± 0.2 C Long term drift < 0.1 C/yr Physical Material 304 Stainless steel Sintered Cap Material Nickel plated bronze Weight 0.1 kg (3.5 oz) International Protection (IEC 60529) Connector Side (IP 67), Cap side (IP 50) Dielectric Strength 4 kv Dimensions 28 W x 28 H x 80 mm D Mounting Body thread Body M22 x 1.5 thread (nut included) 24 mm hex body Installation Manual Page 16 of 33
17 Connector M12, 4-pole socket 4.2 DIMENSIONS The humidity sensor has dimensions of 28 W 80 H x 28 mm D. 4.3 LABEL Figure 9: Humidity Sensor Dimensions The humidity sensor has one label, containing the model number and serial number. Model Number Serial Number Figure 10: Humidity Sensor Label 4.4 MOUNTING OPTIONS Panel Mount: The sensor body can be inserted into a 22.5mm punch out and fastened with a M22 x 1.5 thin hex nut. Bracket Mount: The sensor can be connected to a 90 bracket with the thin hex nut for alternative mounting methods. Bracket size: 44.5 W x 38 H x 38mm L Note that the humidity sensor s sintered cap should be pointed downward or at least be horizontal to prevent collection of condensation inside the sensor. Installation Manual Page 17 of 33
18 4.5 WIRING The Humidity sensor can be wired in multiple configurations. The components are as follows ID# Description Manufacturer Part # 1 Humidity Sensor (Panel or Bracket Mount) IntelliSAW Panel: IH-10 Bracket: IH-BR-10 2 M12 Plug connector (Connector to Humidity sensor or M12-T) Omron XS2G-D423 3 Cable, 4-conductor, shielded, 18awg N/A N/A 4 M12 T connector Phoenix Contact TERM BLOCK PLUG 4POS STR 3.5MM (Connector to CAM-4 or Reader) On Shore Technology OSTTJ Single Connection IntelliSAW Humidity Sensors communicate with low power I2C communications. 4 conductor shielded cable is used for communications between the humidity sensor and a monitoring unit. IntelliSAW offers standard cable lengths for one-to-one connections. Figure 11: Standard wiring from Humidity Sensor to Monitoring Unit Installation Manual Page 18 of 33
19 4.5.2 Series Connect Humidity sensors can be series connected, with the last sensor capable of being up to 100m away. Standard M12 T-connectors and humidity interface connectors are needed. Figure 12: Series Connected Humidity Sensors Star Connect Although the Humidity Sensors can be star connected, it is not recommended as it goes against the standards of serial connections, creating signal reflections. The Maximum cable length for a star connection should be 15m. Standard M12 T-connectors and humidity interface connectors are needed. The wires should be grouped by color in a terminal block. Figure 13: Humidity Star Connection Installation Manual Page 19 of 33
20 5 INSTALLATION WARNING INSTALLATION ASSUMES THE ASSET IS DE-ENERGIZED AND PROPERLY GROUNDED TO ASSURE A SAFE INSTALLATION. PROPER LOCK-OUT TAG-OUT PROCESSES SHOULD BE FOLLOWED BASED ON CUSTOMER REGULATIONS. Failure to follow the instructions given can result in death or serious injury WARNING PROFESSIONAL INSTALLATION REQUIRED. INSTALLATION AND CONFIGURATION SHOULD BE PERFORMED ONLY BY PERSONNEL WHO ARE TECHNICALLY COMPETENT AND AUTHORIZED TO DO SO. LOCAL REGULATIONS REGARDING ELECTRICAL INSTALLATION AND SAFETY MUST BE OBSERVED. Failure to follow the instructions given can result in death or serious injury Typical Installation The following are examples of where sensors and monitoring units could be located within a medium voltage switchgear vertical section. Depending on the asset manufacturer or type of install (retrofit vs. new hardware), all sensor locations may not be possible on system retrofits. Installation Manual Page 20 of 33
21 Figure 14: IEC style Medium Voltage Switchgear Figure 15: ANSI Style Medium Voltage Switchgear Installation Manual Page 21 of 33
22 5.2 TEMPERATURE SENSOR / AIR INTERFACE INSTALLATION IMPORTANT IntelliSAW CAM Platform Sensors Temperature sensors must be installed using the IntelliSAW Configuration Tool while the asset is de-energized. Failure to do so may result in low sensor-to-air interface signal strength and poor operations Required Hardware Temperature sensor installation requires the use of the following hardware: IntelliSAW o Monitoring unit: Reader or CAM-4 o CAM Air Interface with cable o Configuration Tool (software) o USB A to mini cable Laptop Temperature measurement reference (i.e. RTD or Thermocouple) Mechanical o Torque wrenches o Alternative mounting hardware Basic Insulation Level (BIL) Insulation levels are designed to withstand surge voltages, rather than only normal operating voltages. The system must operate below a Basic Insulation Level (BIL) to withstand these surges. With respect to IntelliSAW components, this means specific spacing requirements need to be maintained when installing air interfaces, cables, temperature sensors, humidity sensors, or any other non-earthed conductors. The table below is a recommended IEC spacing guidelines (ANSI are similar): Equip. Class Operating Voltages Withstand Voltage BIL Air Gap (no test) 7.2kV kV 20kV 60kV 100 mm 12kV 10-11kV 28kV 75kV 120 mm 17.5kV kV 38kV 95kV 160 mm 24kV 20-22kV 50kV 125kV 220 mm 36kV kV 70kV 170kV 320 mm Installation Manual Page 22 of 33
23 5.2.3 RF Isolation and Maximum Sensor Count Each IntelliSAW monitoring unit supports up to 12 unique wireless temperature sensors operating in dedicated frequency bands (IS01, IS02, etc.). Typical application environments will require more than one antenna to interrogate the 12 sensors. If a reader interrogates two sensors of the same frequency band, it will be unable to distinguish between the data from either sensor. This means that two sensors having the same frequency band MUST NOT be installed in the same compartment for interrogation by an air interface. Before installation, determine the system configuration based on the required measurement locations and RF isolation. If there is poor RF isolation between compartments or between adjacent cubicles, care must be taken when placing temperature sensors. Most often, a 6 sensors configuration will be used. If there is acceptable RF isolation between compartments and adjacent cubicles, up to 12 sensor can be installed in a cubicle. Although proper isolation may be available, installation may be limited due to the access to asset compartments or the BIL cannot be maintained Sensor Arrangements Sensors should be installed in compartments based on their 3-phase sensor groupings as described in section 2.4 Grouping. If there is RF leakage between cubicles (as is often found in the bus bar compartment of switchgear), sensors in an adjacent cubicle could be interrogated by the air interface, resulting in two sensors of the same frequency band being read. This problem is relatively easily solved with the proper arrangement of sensors in each cubicle. Note the sensor locations need to coincide with the placement of the air interfaces for optimal signal strength. The configurations below show examples of sensors positioning and final frequency band considerations. Based on RF Return loss, the Sensors to Air interface locations should follow the following scheme: Closest to Air interface: Sensor # 1, 2, 11,12 Intermediate: Sensor # 3, 4, 9, 10 Farthest: Sensor # 5, 6, 7, 8 Sensor numbers should not be repeated in adjacent compartments, represented by blue circles in the image below. Installation Manual Page 23 of 33
24 Figure 16: Example Sensor Configuration Mounting Temperature Sensors The SAW temperature sensors can be bolt mounted, tie wrapped with high temperature grade tie wraps, taped with high temperature grade tape or heat shrink. The Temperature sensors can also be installed under insulation boots or insulation tape. Figure 17: Example Temperature Sensor under Insulation Boots Installation Manual Page 24 of 33
25 Temperature sensors must make direct contact with the bus or line they are monitoring. Always use the manufacturer s recommended torque ratings. Figure 18: Example Temp Sensor Install WARNING ALL BIL LEVELS MUST BE MAINTAINED WHEN INSTALLING THE TEMPERATURE SENSORS. THE HEIGHT OF THE SENSORS MUST BE TAKEN ACCOUNT WHEN DETERMINING BIL LEVEL. Failure to follow the instructions given can result in death or serious injury Radiation Patterns The SAW temperature Sensor and Air interfaces have unique radiation patters and rely on an RF reference plane (metal surface) to complete the RF circuit SAW Sensor The SAW Temperature Sensor uses a monopole antenna and has a radiation pattern similar to the image below: Installation Manual Page 25 of 33
26 Figure 19: (Left) Monopole Radiation Pattern. (Right) Pattern Relative to sensor Air Interface The air interfaces are Planar Inverted-F Antennas (PIFA) and have RF emission / radiation patters similar to the image below. This is important to realize when placing an air interface to successfully interrogate a temperature sensor. Figure 20: (Left) Air Interface Radiation Pattern. (Right) Pattern Relative to Air Interface NOTICE The monitoring unit output power is transmitted through the Air Interfaces and is regulated by the FCC. The FCC regulations require the antenna to be installed in metal enclosed compartments similar to the build of a Medium Voltage Switchgear. Using the temperature sensors / air interface in any other capacity will result in diminished signal strength and potential violation of the FCC regulations. Failure to follow these instructions can result in property damage. Installation Manual Page 26 of 33
27 Air Interface and Nearby Metals Note, nearby metal and structures within the asset will affect the radiation patterns and operating frequencies of the air interfaces. It is advised to keep the air interface at a minimum of 100mm away from metal other than the surface on which it is mounted. Figure 21: Keep Air Interface away from nearby metals Metal Obstructions The radiation pattern from an air interface propagates through space until it impinges on something else. If the object is metallic and has sufficient size, the propagating wave reflects off the metallic surface and can cause destructive interference. Since the IntelliSAW temperature sensors need to be located at specific points where temperatures need to be measured, these locations cannot be altered. The only freedom an installer has is to select an air interface location that minimizes any cancellation due to nearby metal structures Sensor to Air Interface Positioning Optimal position between an air interface and SAW temperature sensor will be determined through monitoring the signal strength using the IntelliSAW Configuration Tool. General rules can be applied when positioning the air interface: Optimal position (based on radiation patterns): In this way, the strongest field strengths for each structure are aligned and can help to ensure very good signal levels. Figure 22: Optimal Air Interface to Sensor Positioning Installation Manual Page 27 of 33
28 Intermediate Position. In this case, to prevent excessive loss due to lowered field intensity, try to keep the angle between the ground planes and the center of the structures at 45 or less. Figure 23: Air Interface to Sensors can use angles to ensure proper signal strength Least Optimal: In this case, the structures are aligned so that the SAW Sensor s zone of weakest field strength is facing the Air Interface. A significant reduction in received signal levels can be expected of an air interface aligned in this manner. Figure 24: Least Optimal Positioning Installation Manual Page 28 of 33
29 5.2.7 Air Interface Installation The Air Interfaces are used to interrogate the SAW temperature sensors. The TPD air interface can also monitor PD emissions. Both the TMP (temp only) and TPD are installed the same way. WARNING ALL BIL LEVELS MUST BE MAINTAINED WHEN INSTALLING THE AIR INTERFACES.. Failure to follow the instructions given can result in death or serious injury Air Interface Wiring The Air Interface connects to a monitoring unit through shielded RF cable. When wiring the antenna to a monitoring unit, necessary BIL levels must be maintained during routing of the cable. Air Interface cabling come in standard lengths; cross sections of assets should be used to determine the best distance to minimize extra cable. Wiring shall be completely contained within the asset metal housing, or metal conduit shall be used to protect the cabling. RF cables should not be routed in proximity to MV or HV cables. Even shielded MV and HV cables carry substantial shield currents and voltages. Routing RF cables within the BIL separation of unshielded MV and HV cables can cause partial discharge in the cables and can induce life threatening voltages on ungrounded RF cables. WARNING EXTRA CABLE SHALL NOT BE BUNDLED IN HIGH VOLTAGE COMPARTMENTS. Failure to follow the instructions given can result in death or serious injury Air interface Mounting Use the magnetic mounts to preliminary locate the air interfaces and to optimize location to ensure proper signal strength. The air interface can be left secured by the magnets or alternatively may be bolt mounted once final location is indicated. Use a permanent marker to identify location Optimizing Signal Strength & Configuring the System Once the sensors, antennas and readers have been preliminary installed in the cubicle, use the IntelliSAW software tools to configure the system. A computer with IntelliSAW Configuration Tool and a proper USB interface cable are required. Please refer to the following document to configure a monitoring unit: ( ) IntelliSAW Configuration Tool User Manual and Commission Temperature Sensors. Installation Manual Page 29 of 33
30 Ensure Final Asset Assembly The SAW Sensors and Air Interface rely on adequate RF signals for reliable readings. It is recommended to have asset as close to final assembly as possible - all of the sheet metal panels must be in place, breakers racked in, and all cubicle compartment doors must be closed. Only in this condition will the sensor readings provided by the reader be valid, representing how the temperature monitoring system will behave in actual use. In the example, the cover shown to the left of the opening was used to close up the remaining open area of the switchgear before taking measurements. If the asset is partially assembled, the final signal strength may change and impact readings SAW Temperature Calibration To finalize the installation, the SAW Temperature Sensors must be calibrated through the IntelliSAW Configuration Tool this again assumes the asset is a complete assembly. Sensor Calibration occurs after signal strength between the Air Interface and SAW Sensors has been optimized and verified Calibration Reference A reference measurement from a third party sensor is required for final calibration. Installation Manual Page 30 of 33
31 5.3 PARTIAL DISCHARGE CONFIGURATION IntelliSAW CAM Platform Sensors If the system being installed includes SAW temperature sensors, the TPD Air Interface used for Partial Discharge monitoring should first be setup and configured for optimal SAW sensor locations. Once completed, the PD monitoring frequency configuration can be completed. If the system is not being installed with SAW temperature sensors and is only being used as a PD solution, the Air Interface should be installed to ensure proper BIL is maintained. The location is not critical for PD only application, provided the air interface has a direct view into the enclosure, as emissions will occur within the enclosure and multiple reflections will bring the signal to the air interface. Please refer to the following document to configure PD in a monitoring unit Please refer to the following document to configure a monitoring unit: ( ) IntelliSAW Configuration Tool User Manual and Commission Partial Discharge. 5.4 HUMIDITY / AMBIENT SENSOR INSTALLATION The IntelliSAW humidity sensor is a pre-calibrated humidity and ambient temperature sensor with Sensirion CMOSens technology. Each humidity sensor is individually calibrated in a precision humidity chamber. The calibration coefficients are programmed into an OTP memory on the chip. These coefficients are used to internally calibrate the signals from the sensors. The capacitive humidity sensors provide digital and fully calibrated output that allows for easy integration without the need for additional calibration Mounting The Humidity Sensor uses an M22 x 1.5 body thread and comes with M22 x 1.5 nut. This allows for mounting into a compartment through a hole or a tapped hole. The sensor can also be ordered with a bracket for mounting on internal surfaces. Sensors could also be tie wrapped. While condensation should not occur in electrical assets, the sensor should be installed with the sensing end slightly downward to prevent collection of water in the sensor body Humidity Sensor Wiring Complete the sensor wiring based on the type: one-to-one, series, or star. Wiring shall be completely contained within the asset metal housing, or metal conduit shall be used to protect the cabling. Installation Manual Page 31 of 33
32 5.5 OUTDOOR ASSET INSTALLATION WITH ENVIRONMENTAL ENCLOSURES When installing into outdoor assets such as ISO Phase bus ducts or transformer connector boxes, and an environmental enclosure is required for the reader and for the humidity sensor / air interface connections. All cabling shall be installed in metal electrical conduit. As noted in the image below: 1. IntelliSAW Control environmental enclosure: Designed for Power Environments, the enclosure is a NEMA 4X with an IntelliSAW IRM-48 Reader, Thermostat / Heater, Power Supply, Circuit Breaker, and Surge Suppression. Note conduit connections for air interface and humidity cabling. Multiple types of enclosures are available depending on number of CAM-4 or Readers. 2. IntelliSAW Humidity & Air Interface environmental enclosure: Designed to house a humidity sensor and/or a lightning arrestor for air interface connectors. Multiple types of enclosures are available for single asset or three phase ISO for daisy chaining connections. 3. Conduit: Direct connect conduit can be used to house air interface cables Figure 25: Outdoor installation Installation Manual Page 32 of 33
33 CONTACT Head Office: IntelliSAW 100 Burtt Rd. Andover, MA Regional Office: IntelliSAW LATAM IntelliSAW China Regional Distributors: Visit for the latest distribution locations. Installation Manual Page 33 of 33
Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)
Cisco Aironet.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT588P3M-N) This document outlines the specifications for the Cisco Aironet AIR-ANT588P3M-N.4/5-GHz 8-dBi 3-Port Directional Antenna with N-connectors
More informationCisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949)
Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949) Overview This document describes the 13.5-dBi Yagi mast mount antenna and provides instructions for mounting it. The antenna operates in the
More informationCisco Aironet Six-Element Dual-Band MIMO Patch Array Antenna (AIR-ANT25137NP-R)
Cisco Aironet Six-Element Dual-Band MIMO Patch Array Antenna (AIR-ANT25137NP-R) August 2, 2013 This document describes the AIR-ANT25137NP-R antenna and provides instructions for mounting it. The antenna
More informationCurrent Probes. User Manual
Current Probes User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationSpecification. Part No. : A.90.A
Specification Part No. : A.90.A.101111 Product Name : Bolt High Gain Low Profile GNSS L1 GPS/GLONASS Permanent Mount Antenna with High Out of Band Rejection Features : 30dB GPS Gain, 25dB GLONASS Gain
More informationInstructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION
S&C Alduti-Rupter Switches Outdoor Distribution Three-Pole Double-Break Style and Three-Pole Double-Break Integer Style Live Parts Replacement on Switches with Catalog Number Supplement -R10 34.5 kv and
More informationOMEGA. Communications Interface Cabinet. Antenna Installation Manual
Ω OMEGA Communications Interface Cabinet Antenna Installation Manual 0049-0706-004 The products and programs described in this User s Guide are licensed products of Telenetics Corporation. This User s
More informationMV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer
PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with
More informationCisco Aironet Dual-Band MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2544V4M-R)
Cisco Aironet Dual-Band MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2544V4M-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz/5-GHz Dual-Band MIMO Wall-Mounted Omnidirectional
More informationSpecification. Spartan MA650.A.AB.002
MA650.A.AB.002 on ground-plane Spartan MA650.A.AB.002 Specification Part No. Product Name Feature MA650.A.AB.002 Spartan 2in1 MA.650 with 10M cable length Low Profile Screw Mount (Permanent Mount) GPS/GLONASS
More informationInstallation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna
Release 3.0 NN47251-311 Issue 02.01 June 2014 Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna How to get help To access the complete range of services and
More informationAfrica Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound
Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences
More informationModel 3725/2M. Line Impedance Stabilization Network (LISN) User Manual
Model 3725/2M Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationYagi and Omni Antennas Installation Manual
Yagi and Omni Antennas Installation Manual 25500445 Rev. A0 0218 Printed in U.S.A. Copyright 2018 Federal Signal Corporation Limited Warranty This product is subject to and covered by a limited warranty,
More informationInstallation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION
Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant
More informationWORLD-BEAM QS18AFF200 Sensors with Foreground Suppression
WORLD-BEAM QS8AFF00 Sensors with Foreground Suppression Datasheet Compact sensors featuring extended range and foreground suppression mode Exceptional optical performance; up to 00 mm sensing range in
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationSPECIFICATION. Part No. : MA673.A.CGH.004. Product Name : Spartan Antenna 3in1 MA673. Features : ac compatible
SPECIFICATION Part No. : MA673.A.CGH.004 Product Name : Spartan Antenna 3in1 MA673 Low Profile Screw-Mount (Permanent Mount) 3 * 2.4/5.8GHz MIMO 802.11ac antenna Features : 802.11ac compatible IP67 Waterproof
More informationAdvancements in online partial discharge monitoring and assessment of MV through EHV Substation assets
Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Abstract: For decades it has been recognized that partial discharge assessment is an excellent method
More informationApplication Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems
Application Note 50532 (Revision NEW) Original Instructions EMI Control in Electronic Governing Systems General Precautions Read this entire manual and all other publications pertaining to the work to
More informationModel BiConiLog Antenna. User Manual
Model 3149 BiConiLog Antenna User Manual ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been
More informationSIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4
Characteristics 1 Ordering data 2 SIMATIC Ident RFID systems Operating Instructions Installing and mounting 3 Connecting the antenna 4 Antenna parameter assignment 5 Antenna patterns 6 Maximum read/write
More informationTC ANT MOBILE... Mobile communication antennas and antenna cables. Data sheet _en_00. 1 Description
Mobile communication antennas and antenna cables Data sheet 106760_en_00 PHOENIX CONTACT 2015-08-11 1 Description This data sheet describes the accessories for mobile communication products. All mobile
More informationMODEL 3810/2 Line Impedance Stabilization Network
EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047
More information2011 / Circuit Tracer
INSTRUCTION MANUAL 2011 / 00521 Circuit Tracer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52044992 2008 Greenlee Textron
More informationHughes 9450 Mobile Satellite Terminal. Installation Guide
Hughes 9450 Mobile Satellite Terminal Installation Guide 3004129 Revision A September 15, 2010 Copyright 2010 Hughes Network Systems, LLC All rights reserved. This publication and its contents are proprietary
More informationCisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506)
Cisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506) This document outlines the specifications, describes the omnidirectional mast mount antenna, and provides instructions for mounting it. Designed
More informationINSTRUCTION MANUAL. Model 18AVQII Five Band Vertical Antenna 10, 15, 20, 40, 80 Meter. General Description. Theory of Operation
Model 18AVQII Five Band Vertical Antenna 10, 15, 20, 40, 80 Meter 308 Industrial Park Road Starkville, MS 39759 (662) 323-9538 Fax: (662) 323-5803 INSTRUCTION MANUAL General Description The Hy-Gain 18AVQII
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More informationCisco Aironet 12 dbi High Gain Omnidirectional Antenna (AIR-ANT24120)
Cisco Aironet 12 dbi High Gain Omnidirectional Antenna (AIR-ANT24120) Overview This document outlines the specifications and description of the 12-dBi high gain omnidirectional antenna. This antenna operates
More informationUser Guide. Keysight N6850A Broadband Omnidirectional Antenna
User Guide Keysight N6850A Broadband Omnidirectional Antenna Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationHP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide
HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide SAFETY The HP ProCurve J8999A and all associated equipment should be installed in accordance with applicable local and national electrical
More informationGuide. Installation. Wilson Electronics, Inc. Direct Connection High Power iden Amplifi er 800 MHz Band. Contents:
Amplifier Installation Guide Direct Connection High Power iden Amplifi er 800 MHz Band Contents: Guarantee and Warranty 1 Before Getting Started / How it Works 3 Installing a Wilson Outside Antenna - In-Vehicle
More informationDouble-Ridged Waveguide Horn Antennas
Models 3112, 3106B, 3119, 3115, 3117, 3116C Double-Ridged Waveguide Horn Antennas User Manual ETS-Lindgren Inc. Although the information in this document has been carefully reviewed and is believed to
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationUSER MANUAL RM050A-R3, RM051A-R3 WALLMOUNT RACKS 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM
USER MANUAL RM050A-R3, RM051A-R3 ULTRA WALLMOUNT RACKS 24/7 AT OR VISIT BLACKBOX.COM TABLE OF CONTENTS PREFACE... 3 Safety Symbols Used in this Manual...3 Safety Considerations...3 1. SPECIFICATIONS...
More information670K9 SORtrax Level Transmitter
SORtrax is a 4-20 ma continuous level transmitter. It produces a 4-20mA current superimposed on the 12-55 VDC loop supply lines. The 4-20mA current is proportional to the level sensed by the instrument.
More informationmicro DOUBLE TEN SWITCH
micro DOUBLE TEN SWITCH microham fax: +421 2 4594 5100 e-mail: support@microham.com homepage: www.microham.com 5 December, 2011 1 TABLE OF CONTENTS CHAPTER PAGE 1. IMPORTANT WARNINGS... 3 2. DESCRIPTION...
More informationType DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv
Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv DMX-N gapless metal oxide surge arresters DMX-N surge arresters are used for the protection of switchgear, transformers and other equipment
More informationModel 3180B Mini-Bicon Antenna User Manual
Model 3180B Mini-Bicon Antenna User Manual Model 3180B with conical elements Model 3180B with cage elements ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order
More informationSTOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets
Rev. 04 STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID NET-ACCESS S-Type Network Cabinets -Phillips screwdriver -Flatblade screwdriver -22mm socket wrench -15mm socket wrench
More informationGuide. Installation. Wilson Electronics, Inc. In-Building Wireless Amplifi er. Contents:
Amplifier Installation Guide In-Building Wireless Amplifi er Contents: Guarantee and Warranty 1 Antenna Options and Accessories 2 Before Getting Started / How It Works 2 Installation Overview 3 Installation
More informationLog Periodic Dipole Array Antenna
Model 3148B Log Periodic Dipole Array Antenna User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason.
More informationFrom dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).
121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and
More informationDynamo Brushless DC Motor and GreenDriveTM Manual
Dynamo Brushless DC Motor and GreenDriveTM Manual This manual was developed as a guide for use by FIRST Robotics Teams using Controller Part Number 840205-000 in conjunction with the Nidec Dynamo BLDC
More informationMFJ-1750/1752 2M BASE ANTENNA with 5/8 GROUND PLANE Instruction Manual
MFJ-1750/1752 2M BASE ANTENNA with 5/8 GROUND PLANE Thank you for purchasing the MFJ-1750/1752. The 1750 is a 5/8 wave antenna designed for operation on 144-148 MHz. The 1752 is designed to operate on
More informationHeavy Duty Screw Mount Antenna - Dual-Band GHz
Hercules WS.01.B.305151 Description: Heavy Duty Screw Mount Antenna - Dual-Band 2.4 5.2GHz Features: 2.4GHz 5.2GHz suitable for ISM Bands/ZigBee/WLAN/Bluetooth IEEE.802.11/IEEE.802.15 UV and Vandal Resistant
More informationEVID Surface Mount S Series - X Models
EVID Surface Mount S Series - X Models EVID-S5.2XB EVID-S5.2XW en Installation manual en 3 Table of contents 1 Safety 4 1.1 Suspension 4 1.2 Notices 4 2 Introduction 5 2.1 System features 5 2.2 Product
More information3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA
LINK GPS MGMT DATA DATA MGMT GPS LINK 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA DATA MGMT GPS LINK Introduction Thank you
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION 16075 ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationIN-BUILDING ANTENNAS
Ceiling Mount Antenna, 4G LTE MIMO, PIM160 VenU PIM160-ICM Ultra Flat Dual-Polarization LTE MIMO Ceiling Mount Antenna The PIM160-ICM is a dual-polarization LTE MIMO antenna with ultra-low PIM (@ 2x43
More informationCisco Outdoor Omnidirectional Antenna for 2G/3G/4G Cellular (ANT-4G-OMNI-OUT-N)
CHAPTER 4 Cisco Outdoor Omnidirectional Antenna for 2G/3G/4G Cellular (ANT-4G-OMNI-OUT-N) The Cisco Outdoor Omnidirectional Antenna for 2G/3G/4G Cellular antenna is designed to cover domestic LTE700/Cellular/PCS/AWS/MDS,
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationDOCUMENT TR2028/R3- PICO BASE STATION WITH GPS SYNC
19473 Fraser Way,Pitt Meadows, B.C. Canada V3Y 2V4 Phone (604) 460-6002 Fax (604) 460-6005 www.tranzeo.com DOCUMENT TR2028/R3- PICO BASE STATION WITH GPS SYNC HARDWARE INSTALLATION GUIDE Thank you for
More informationHLC-1000 High-limit Humidity Control
FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification
More informationRADOME OMNI ANTENNA GHz, 6 dbi, FOAM FILLED
RADOME OMNI 5.15-5.975 GHz, 6 dbi, FOAM FILLED PAGE 1/8 ISSUE 1525 SERIES RADOME OMNI 5.15-5.975 GHz, 6 dbi, FOAM FILLED PAGE 2/8 ISSUE 1525 SERIES ELECTRICAL CHARACTERISTICS Frequency:..... 5150-5975
More informationINTELLIMETER REGISTER
INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationFW / FIG Partition Kit(s) Installation Instructions
FW / FIG Partition Kit(s) Installation Instructions This instruction explains how to join 8 in. and 10 in. top piping partitions to FIG and FW merchandisers. Do not remove the shipping braces until the
More informationAppearance of device and accessories may vary.
Tri-Band 4G-V Adjustable Gain 700 (Band 13) / 800 / 1900 MHz In-Building Wireless Smart Technology Signal Booster (Band 13 is 700 MHz Verizon LTE) Tri-Band 4G-A Adjustable Gain 700 (Band 12/17) / 800 /
More informationINSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500
INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500 Specifications: Designed for in-wall installation spanning a minimum of 3 wood studs, 16" on center. Accomodates MWR, PWR and
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed
More information40 mm Beam Pitch General Purpose Area Sensor. Failure monitoring
OTHER SUNX PRODUCTS NA0 SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Interference prevention Slim and intelligent Refer to p.9l for the light curtain. Slim body Failure monitoring
More informationBulk Current Injection Probe Test Procedure
Bulk Current Injection Probe Test Procedure 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 6 SAFETY 8 FIGURES 9 FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION CURRENT PROBE
More informationA-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE
A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE A-dec 574L Dental Light Mounted on an A-dec Inspire TM 59 Central Console Before You Begin. Turn off the power to the system before
More informationEMI Installation Guidelines
EMI Installation Guidelines Although Red Lion Controls Products are designed with a high degree of immunity to Electromagnetic Interference (EMI), proper installation and wiring methods must be followed
More informationCopyright Black Box Corporation. All rights reserved.
Copyright 2004. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JULY 2004 LW6200A LW6201A Pure Networking 2.4-GHz Antennas CUSTOMER SUPPORT
More informationSureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery
SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery Node with an integrated battery for the EZ-LIGHT family 900 MHz, Internal battery model Features The SureCross DX80 is a radio frequency network
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects
929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~
More informationWEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K
O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationOMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz
INSTRUCTION MANUAL OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM-6865 2 GHz - 18 GHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PRO- PRIETARY. UNAUTHORIZED REPRO- DUCTION
More informationQuick Release Hardware
Backs and Support OWNER MANUAL Quick Release Hardware TFB Hardware Quick Release Owner s Manual Customer Satisfaction 1.0 Stealth Products strives for 100% customer satisfaction. Your complete satisfaction
More informationMighty Mo GX Series Cabinet Installation Guide. OR Rev /11
Mighty Mo GX Series Cabinet Installation Guide OR-71601787 Safety and Warning ATTENTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating
More informationModel 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents
Model 0-MMPC-L Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 877 Aurora Road Quick Start Guide Cleveland, Ohio 9-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments Model
More informationGuide. Installation. Wilson Electronics, Inc. In-Building Wireless Amplifi er. Contents:
Amplifier Installation Guide In-Building Wireless Amplifi er Contents: Guarantee and Warranty 1 Antenna Options and Accessories 2 Before Getting Started / How It Works 3 Installation Overview 4 Installing
More information4-Port Antenna ircu / /65 16/18.5dBi 0 10 /0 10 T V01
4-Port Antenna Frequency Range Dual Polarization Half-power Beam Width Integrated replaceable Remote Control Unit Adjustable Electrical Downtilt 0 10 0 10 4-Port Antenna 698 894/1710 2170 65 /65 16/18.5dBi
More informationWORLD-BEAM QS18AF Sensor with Background Suppression
WORLD-BEAM QS8AF Sensor with Background Suppression Datasheet Compact sensors featuring extended range and background suppression mode Exceptional optical performance; up to 00 mm sensing range in compact
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LF 21-S/SPA2 I P N = 2 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationI P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017
Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and
More informationCP /240-MC4 User Manual
CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...
More informationSPECIFICATION. G21 GSM Hercules Gen.II Penta Band Cellular Antenna. Screw-mount (Permanent mount)
SPECIFICATION G21 GSM Hercules Gen.II Penta Band Cellular Antenna Part No. : G21.B.301111 Product Name : Hercules Gen.II Penta Band Cellular Antenna Screw-mount (Permanent mount) Features : GSM/GPRS/CDMA/EVDO/UMTS/HSPA/WCDMA
More informationSPECIFICATION. Heavy Duty Screw Mount Antenna. Features : Wi-Fi/ISM Bands/ZigBee/WLAN/ Bluetooth. UV and Vandal Resistant ABS Housing
SPECIFICATION Part No. : WS.02.B.205111 Product Name : 4dBi 2.4GHz Omni-Directional Heavy Duty Screw Mount Antenna Features : Wi-Fi/ISM Bands/ZigBee/WLAN/ Bluetooth UV and Vandal Resistant ABS Housing
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationRIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc
User s Guide RP1000D Series High Voltage Differential Probe Feb. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2012 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information
More informationS5-ADU. Front... 4 Rear... 4
Trantec ANTENNA DISTRIBUTOR INSTRUCTION MANUAL S5-ADU Thank you for purchasing TRANTEC Antenna Distributor. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationSpecification. Spartan MA605.A.ABC in1 MA.605 Low Profile Screw-Mount (Permanent Mount) GPS/GLONASS/Cellular/2.4GHz ~ 5GHz Combination Antenna
MA65.A.ABC.1 on ground-plane Spartan MA65.A.ABC.1 Specification Part No. Product Name Feature MA65.A.ABC.1 Spartan 3in1 MA.65 Low Profile Screw-Mount (Permanent Mount) GPS/GLONASS/Cellular/2.4GHz ~ 5GHz
More informationMPR kHz Reader
MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied
More informationParadigm. Connect100 Installation Guide
Paradigm GX Connect100 Installation Guide Paradigm GX Safe Use WARNING Radiation Hazard. Transmitter power levels are sufficient to cause blindness or other serious injury to body tissue. Do not power
More informationWireless Transceiver (TRV)
Installation and Operation Manual Wireless Transceiver (TRV) For Platinum Controls with Communication WARNING This equipment complies with the limits for a Class B digital device, pursuant to Part 15 of
More informationCurrent Probe Fixture Instruction Manual
Current Probe Fixture Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 5 SAFETY 7 FIGURES 8 FORMULAS 10 MAINTENANCE 11 WARRANTY 12 2 INTRODUCTION figure 1 Mechanical
More informationPlease read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.
Attachment Tab Height: 16-1/2 Serial Number Attachment Tab Width: 24 Please read BOTH these and the General Instructions prior to installing or operating this equipment. 1. Blue Ox towing products and
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LF 2010-S/SPA0 I P N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and
More informationPICO-AMP Miniature Remote Sensing System
PICO-AMP Miniature Remote Sensing System MD14 Modulated Amplifer and Ultra-small Remote Sensors PICO-AMP Features Ultra-small remote sensors to fit the tightest locations Three fixed frequency selections
More informationAN-80i. Advanced Broadband Wireless Infrastructure Solutions. 3 GHz Antenna Guide
Advanced Broadband Wireless Infrastructure Solutions 7-125-1-2a Proprietary Redline Communications 11 Page 1 of 28 February 18, 11 Copyright Information All rights reserved February 18, 11. The information
More informationK1FO 12 ELEMENT 144/147 MHz YAGI
K1FO 12 ELEMENT 144/147 MHz YAGI WARNING: INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS. FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS. Ariane Arrays, Inc. Copyright 2006 201 Hopedale
More information