PULSE TRANSDUCER K816 / IWe2. Operating Instructions

Size: px
Start display at page:

Download "PULSE TRANSDUCER K816 / IWe2. Operating Instructions"

Transcription

1 PULSE TRNSDUCER K816 / IWe2 Operating Instructions Operating Instructions s per: 10/10/2003 Copyright by FTL K816_IWe2_Bed_ _engl.doc

2 GENERL INFORMTION With this two-stage transducer it is possible to multiply the value of a measuring pulse by a whole-numbered or fraction-numbered factor. The factor is freely selectable from 1/255 F2/F1 255/1. The values of the numerator (F2) and the denominator ( F1) of the factor desired are separately adjustable (binary coded). Then, the valency of an output pulse I calculates itself with I = IE x F2/F1, with IE as value of an input pulse. Frequencies can also be transformed with the IWe2: f.off = f.on x F1 / F2. If F1 > F2, then the output frequency is unsteady. Some examples of applications : Electricity-measurements: Standardization of non-decadal pulse values of pulsing counters. Gas measurement: daptation of pulsing devices to existing tariff devices, conversion of gas volumes into thermal energy via constant factor, consideration of K-number as constant, control of odorization-pumps. Water measurement: conversion of an HF-signal into a LF-signal for telecommunication and tele-counting purposes. General measuring technique: Pulse measuring technique / counting / evaluating / controlling Essential features: Compact, assembly-friendly plastic housing internal auxiliary supply for transducer circuit Input circuit for most common transducer types available Signal separation via relay or optocoupler Settings protected against accidental adjustments via inlying switches Output in two versions: Relay (250V - 0,5 60W) or optocoupler (24V - 20m - 0,1W) and Open Collector (12V - 15m). Page 2 of 8

3 TECHNICL DT Housing dimensions: W x H x D : 40 x 70 x 110 mm; Suitable for 35 mm installation rail or wall fastening V +8,2V E IWe 2 K816 Impulswandler 250V/2 60W V, 50/60Hz V 15m N L Material: NORYL Protection category: IP30 Elektronik und Feingerätebau TRITSCHLER GmbH Schönaustr / D Laufenburg Telephone: / ; FX : / info@ftl.de Internet: 20 spring clips for wire gauges up to 2,5 mm² 230V~/115V~/24V~/24V=/12V= PE-connection not necessary. Internal fuse (5 x 20 mm, DIN 41571): 230/115V~ : F0,1; 12/24V~= : F 0,63 uxiliary supply internal: +8,2V (clamp 2) clamp 3, suitable for potential-free contacts, proximity switch according to NMUR With ground-referenced signals: Reference potential to Cl. 5, signal level maximum 24Vdc. Relay contact: (clamps 7,8,9) Loadable with maximum 250V~, 2, 60W Or Optocoupler (clamps 7 and 9): Loadable with maximum 24Vdc, 20m, mind polarity! Open Collector : PNP-Transistor, collector on clamp 4; The emitter is connected with the inner operating voltage of 12V. The output may only be loaded with 15m (minimum resistance: 800 ohm). If external voltages are to be connected, it is necessary to mind a proper potential separation to the supply circuit. Manufacturer Connection Supply voltage Signal input Outputs Page 3 of 8

4 Operating temperature: -10 / +70 C Temperature range for storage: -25 / +80 C Humidity: No condensing atmosphere Emitted interference / Interference resistance: CE-conformity. The function is characterized by 4 parameters: Temperature EMV Operational range Factor F1 : djustment range : 1 to 255, binary-coded Factor F2 : djustment range : 1 to 255, binary-coded Working frequency f_ Pulse duration (output) t.ia The values for f_ and t.ia which can be reached by the internal components are specified on the device, as well as the values the respective device has been adjusted to in factory. Lock device onto a top hat rail (35 mm installation rail) and screw catch into fixing position by help of a screw driver. With wall fastening 2 screws are necessary (Diameter d : 3 to 5 mm). Installation Establish connecting lines to the other MSR-components. Connect power supply and put on voltage. Initial operation The connection to the potential equalization (ground) is not always necessary. The respective connection point will only be offered for respective supply feed lines. Normally, maintenance is not necessary. Change fuses: If it is necessary to exchange fuses, the cause of fault must firstly be cleared. If the fault was outside the IWe2, the fuse may be exchanged by disconnecting and subsequently opening the device. Then, the fuse can finally be exchanged. Please use only fuses which have the same electrical characteristics. (With 230Vac and 115Vac-devices: 0,1 Flink, with 24V or 12Vdc: 0,63 Flink) In case error diagnostic is still unclear, the device must be sent to the manufacturer. Maintenance Page 4 of 8

5 INSTRUCTIONS FOR RE-PRMETERIZTION The device must only be re-parameterized in the factory or by especially trained personnel and competent persons. For the re-parameterization of f_ and t.ia it is necessary to work on the device when it is energized. It is strictly necessary to adhere to the respective accident prevention regulations. Normally, maintenance is not necessary. Determine the new parameters desired and specify the default values for F1, F2, f_ and t.ia. Tools necessary: screw driver ( /, size 1), frequency meter, pulse duration meter (e.g. oscilloscope), auxiliary for opening the housing. Open device by pressing back the 4 side locking pins while simultaneously pulling the connection head out of the housing. Pull out connecting part with both circuit boards until the adjustment switches for F1 and F2 become accessible. If changes of f_ or t.ia are necessary, these parameters will conveniently be adjusted at first. Preparation Realization Connect device to power supply. Put all switches on F1 and F2 into position OFF. Put start pulse onto pulse input whereby the oscillator starts. Measure frequency at test point f_ (Pin 10 of IC3 or IC ) and adjust desired frequency by turning the potentiometer P1 on the control circuit board. Modifying the working frequency f_ Connect device to power supply, put all switches of F1 onto OFF, shift switches of F2 onto new adjustment desired. Connect pulse duration meter (e.g. oscilloscope) to the measuring point for t.ia (at the outer connector of the light emitting diode LED1). Put start pulse onto pulse input whereby the oscillator starts and its frequency, divided by F2, will be fed to the power unit and the output circuit board. djust the desired output pulse duration t.ia at the potentiometer P1 of the power unit and output circuit board. Modifying the output pulse t.ia Page 5 of 8

6 Determine the binary parts of the desired factor by forming the factor as sum of the respective binary coefficients. djustment of factors F1 and F2 F1 F2 OFF ON OFF ON S1: 2 0 = 1 dez S2: 2 1 = 2 dez S3: 2 2 = 4 dez S4: 2 3 = 8 dez S5: 2 4 = 16 dez S6: 2 5 = 32 dez S7: 2 6 = 64 dez S8: 2 7 = 128 dez Example: If Fx is to be = 100, the switches for the coefficients , as S7, S6 and S3 must be in position ON, all others on OFF. In order to adjust the respective switches, it is recommended to use a small screwdriver. It is also advisable to shift the switch multiple times to and fro, before it remains in its desired position. If it is not possible to reach the new values for f_ and t.ia via the adjustment of the potentiometer, the components of the oscillator must be exchanged. This may only be carried out by FTL and can normally only be performed in factory. Close device after re-parameterization has been finished. Here, it is necessary to pay attention that the locking pins have been locked properly. Check device by means of new values. Note changed values as new settings on the device, create respective revision notification (informal) and add to device documentation. Determine default values from process: Pulse value of a control pulse (I.E) Shortest occurring distance of two input pulses (t.per.min) Minimum distance necessary Of two output pulses (t.ia.diff.min) Necessary value of an output pulse (I.) Necessary (minimum)duration of an output pulse (t.ia.target). Process for determination of parameters Page 6 of 8

7 Determine whether parameters can be adjusted or not: Is t.ia.target within the adjustment range t.ia specified on the device? Is it possible to represent the relation I. / I.E as whole-numbered fraction F1/F2 (F1 and F2 are to be selected as small as possible in the range from 1 to 255)? The working frequency value which is necessary for the application can be selectedc between f_.min = F1 / t.ie.min and f_.max = F2 / t.ia.diff.min. Is f_.min < f_.max and is a value for the necessary working frequency within the adjustment range for f_ specified on the device? If all questions could be answered with yes, the device can be adjusted for the use case. Example: I.E = 10/9 kwh (= 1,111..kWh) (e.g. given by the electric meter with pulsing device) t.ie.min = 0,4 sec (e.g. from maximal possible instantaneous power 10MW) I. = 1,0 kwh (e.g. due to decadal meter factor) t.ia.diff.min = 0,2 Sek (e.g. since meter can process pulses up to 5 Hz) t.ia.target = 100 msec (e.g. since meter exfiltrates shorter pulses as disturbing pulses) Ranges specified at IWe2: 50 msec < t.ia < 1500 msec 1,6 Hz < f_ < 88 Hz 100 msec is in the range msec: Thus, Ok t.ia Check 1 / (10/9) = 9/10 = F1/F2: Thus, the relation is exactly adjustable: Ok f_.min = F1 / t.ie.min= 9 / 0,4 = 22,5Hz I./I.E Calculation of f_.min f_.max = F2 / t.ia.diff.min = 10 / 0,2 = 50Hz Calculation of f_.max f_.min < f_.max? Yes: Thus, Ok f_-test 22,5 to 50 Hz contained in the range 1,6 to 88 Hz? Yes: Thus, Ok The values necessary are now adjustable, the re-parameterization can be carried out. Page 7 of 8

8 ORDER Order number G Pulse transducer K816 / IWe 2 Voltage Output type 1 Input, control for potential free contacts, transistor switches or Pulse transmitters according to NMUR-regulation DIN 19234, 230V / 3V 1 relay output, instead optional transistor output (optocoupler), plastic housing for 35 mm standard rail adjustment range 1:255 to 255/1 via DIL-switch; Basic setting: 1/1 working frequency: adjustment range (Poti) 1-20 Hz; Basic setting: 5 Hz output pulse duration: adjustable (Poti) 0,1-2 sec; Basic setting: 100 msec V 1. 24Vdc without galvanic isolation 2. 24Vdc with galvanic isolation. 0 Relay output. 1 Optocoupler output Services for K816 / IWe 2 D Customer-specific parameterization according to specification data sheet +12V +8,2V E IWe 2 K816 Impulswandler +12V 15m +12V +8,2V E IWe 2 K816 Impulswandler +12V 15m 250V/2 60W 230V, 50/60Hz N L 30V/100m p< 0,2W 24V =/~ Feingerätebau TRITSCHLER GmbH Schönaustr D Laufenburg info@ftl.de Page 8 of 8

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection... instrumentación para fluidos CI- pulse / ma Converter Instruction Manual TABLE OF CONTENTS PRINCIPLE OF OPERATION.... Limitations.... INSTALLATION.... Mains connection........ Input connection........

More information

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

MINI MCR-SL-UI-f(-SP)

MINI MCR-SL-UI-f(-SP) Configurable Analog Frequency Transducer INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The configurable analog frequency transducer MINI MCR-SL-UI-f(-SP) is used to convert analog standard

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications L Mobile Communications MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2 Printed in U.S.A Maintenance Manual TABLE OF CONTENTS Page SPECIFICATIONS.....................................................

More information

Thermocouple - Transducer

Thermocouple - Transducer Thermocouple - Transducer TM3 Characteristics: Thermocouple type J, K, R, S, T, E, B, N Linearity error < 1% Measurement range configurable -210...+1820 C Built-in cold junction compensation Galvanic 3-way

More information

RS485 AMR Interface E350 User Manual

RS485 AMR Interface E350 User Manual Page 1 from 6 General Upgradable for future communication needs: flexible remote communication modules without breaking approval seal. The new series of modules for domestic use puts promises into practice,

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Technical Description. DCF77 Receiver-Module 4460

Technical Description. DCF77 Receiver-Module 4460 Technical Description DCF77 Receiver-Module 4460 Version 09.02 23.07.2002 COMPANY INFO Safety information The Safety Instructions and Technical Data serve to ensure trouble-free operation and protection

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Short-circuit-proof switching amplifier for inductive loads up to 10 A

Short-circuit-proof switching amplifier for inductive loads up to 10 A MICROOPTO Overview Short-circuit-proof switching amplifier for inductive loads up to 10 Powerful, compact solid-state relay with error signalling contact The MICROOPTO family offers the customer high-quality

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

DESCRIPTION NOTE. Power Supply MODEL 2200A PM

DESCRIPTION NOTE. Power Supply MODEL 2200A PM Instantly integrate any standard power meter with a pulse output into the LonWorks digital network. The firmware executes on a NeuroLogic Research Model 2200A and provides a low-cost interface to two power

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

PULSE/FREQUENCY/CONDITIONER USER GUIDE

PULSE/FREQUENCY/CONDITIONER USER GUIDE PULSE/FREQUENCY/CONDITIONER USER GUIDE D2560-02-02 CN5220 1600F USER GUIDE Page 1 of 13 PULSE/FREQUENCY/CONDITIONER USER GUIDE FREQUENCY INPUT PSU 1 2 + - SUPPLY (to4) Vdc (to32) Vac UNIVERSL Excitation

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

CEC VIBRATION TRANSMITTER

CEC VIBRATION TRANSMITTER CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:

More information

High precision measurement system for current and voltage IHC-A/B-RM01/03

High precision measurement system for current and voltage IHC-A/B-RM01/03 Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

ENS31 Automatic Isolation Unit Product Description

ENS31 Automatic Isolation Unit Product Description ENS31 Automatic Isolation Unit Product Description Issue 09/2005 UfE Umweltfreundliche Energieanlagen GmbH Joachim-Jungius-Straße 9 D 18059 Rostock Tel.: +49 3 81 / 405 97 05 Fax: +49 3 81 / 405 97 03

More information

1 Second Time Base From Crystal Oscillator

1 Second Time Base From Crystal Oscillator 1 Second Time Base From Crystal Oscillator The schematic below illustrates dividing a crystal oscillator signal by the crystal frequency to obtain an accurate (0.01%) 1 second time base. Two cascaded 12

More information

ENS26 Automatic Isolation Unit Product Description

ENS26 Automatic Isolation Unit Product Description ENS26 Automatic Isolation Unit Product Description Issue 09/2005 UfE Umweltfreundliche Energieanlagen GmbH Joachim-Jungius-Straße 9 D 18059 Rostock Tel.: +49 3 81 / 405 97 05 Fax: +49 3 81 / 405 97 03

More information

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm. Distance-settable Photoelectric Sensor FC-AL Distance-settable Photoelectric Sensor with Background Suppression and Visible Laser Beam Reliable background suppression detection, even of shiny objects Detection

More information

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants Vibro-Meter Vibration Monitor FEATURES Absolute vibration measurement Monitoring of machines and industrial plants Suitable for velocity transducers (CV...) and piezoelectric accelerometers (CA... / CE...)

More information

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF KB Part No. 9474 Signal Isolator for KBVF Controls See Page 1 Pending See Safety Warning on Page 1 The information contained in this manual is intended

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information

Continental Hydraulics Installation Manual CEM-PA-A

Continental Hydraulics Installation Manual CEM-PA-A CEMPAA Description: This closed loop PID amplifier drives a single solenoid proportional pressure or flow control valve coil up to 2.6A. It is suitable to provide precise closed loop control in pressure,

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

M302RM OPERATING MANUAL

M302RM OPERATING MANUAL M302RM OPERATING MANUAL The Model 302RM is a Linear, high voltage, differential amplifier designed to drive a capacitive load such as Conoptics 350, 360, 370 series E.O. modulators. The amplifier is DC

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL

More information

U S E R S M A N U A L

U S E R S M A N U A L U S E R S M A N U A L T H E R M O R E G U L A T O R T R 5 0 0 / T R 5 0 1 S E R I E S HUNDREDTHS VERSION ENGLISH V.1.2 TABLE OF CONTENTS -1- Introduction... page 2-2- Technical specifications -3- Description

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

USER'S GUIDE. Power Transducer WA / RA / WR. Review I

USER'S GUIDE. Power Transducer WA / RA / WR. Review I USER'S GUIDE WA / RA / WR Table of Contents Chapter Page Introduction 3 Term of Warranty 3 Technical Features 4 Wiring Diagrams 6 Single element, two-wire transducer WA or RA 6 Single element, two-wire

More information

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual PHV 1000-RO High Voltage Passive Probe Instruction Manual Copyright 2014 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

PHV RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual PHV 1000-3-RO High Voltage Passive Probe Instruction Manual Copyright 2012 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

TZIF 4. Current-to-Pulse Converter 10/ EN

TZIF 4. Current-to-Pulse Converter 10/ EN TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote

More information

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Section Two: Power Checks Page 2 Check box when completed Power Checks TEST

More information

High Voltage Power Supplies HCE - Series

High Voltage Power Supplies HCE - Series High Voltage Power Supplies HCE - Series power class 7W and 35W certified according to DIN EN ISO 9001 Operating Instructions This instruction is only dedicated to electrical experts and people with a

More information

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o

More information

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information London Electronics Limited Thorncote Road, Near Sandy, Bedfordshire SG19 1PU Tel +44(0)1767 626444 Fax +44(0)1767 626446 www.london-electronics.com help@london-electronics.com Triple output loop splitter

More information

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features Uninterruptible power supply Data sheet 105623_en_00 PHOENIX CTACT 2013-06-07 1 Description Uninterruptible power supply units continue to deliver power even in the event of mains breakdowns or failures.

More information

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Torque min. 0 in-lb Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) pplication For proportional modulation

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Cable transducer Analog output / redundant Measuring length absolute up to 5 m Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

WESTREX RA-1712 PHOTOGRAPHIC SOUND RECORD ELECTRONICS

WESTREX RA-1712 PHOTOGRAPHIC SOUND RECORD ELECTRONICS INTRODUCTION The RA-1712 solid state Record Electronics is an integrated system for recording photographic sound tracks on a Westrex photographic sound recorder. It accepts a 600Ω input signal level from

More information

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006 PRI Ltd. 9600-3004-2 Issue C Information contained within this document is subject to change without notice and does not represent

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

User guide version v1.1

User guide version v1.1 SOLAR SYSTEM REGULATOR DX 4201 User guide version v1.1 Námestovo, October 2015 Content 1 INTRODUCTION...3 2 CONTROL FUNDAMENTALS...4 2.1 REGULATION FUNDAMENTALS...4 2.2 DRAIN-BACK SYSTEM...5 2.3 PUMP PERFORMANCE

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for sensors with incremental output Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic preselection counter Contents Page 1 Safety instructions 2 2 Getting to know the counter 4 3 Counter connection 4 3.1 Connecting the power

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

DESCRIPTION NOTE MODEL 2200VM

DESCRIPTION NOTE MODEL 2200VM Instantly integrate any volume measurement meter such as water or gas meters into the LonWorks digital network. The firmware executes on a NeuroLogic Research Model 2200 and provides a low-cost interface

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

When you have completed this exercise, you will be able to determine ac operating characteristics of a

When you have completed this exercise, you will be able to determine ac operating characteristics of a When you have completed this exercise, you will be able to determine ac operating characteristics of a multimeter and an oscilloscope. A sine wave generator connected between the transistor base and ground

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

AC-DC ITE & Medical Switching Power Supply

AC-DC ITE & Medical Switching Power Supply KEY FEATURES U Bracket Medical Switching Power Supply Remote ON/OFF Function 200 Watt with Free Air Convection 500 Watt with 30CFM FAN Built-in 12V/0.3A Auxiliary Standby 5V@1A with Fan, @0.4A without

More information

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval Solid-State Timer Analog Set Multifunction Timers in Slim Design for Track Mounting All settings are made though front panel Six operating modes in a single timer provides flexibility for many applications

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

Technical Manual Condor Acceptor

Technical Manual Condor Acceptor Technical Manual Condor Acceptor Teach and Run NOTE To meet the requirements for EN 60950 the equipment must be installed according to the following requirements: The equipment must be protected by a 3A

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information