FLEX I/O and FLEX Integra

Size: px
Start display at page:

Download "FLEX I/O and FLEX Integra"

Transcription

1 FLEX I/O and FLEX Integra Technical Data 1794 Series and 1793 Series Flexible, Inexpensive, and Compact Additional Savings for Larger Systems Compatibility Now and In the Future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

2 2 Overview FLEX I/O and FLEX Integra Product Data Low Installation, Wiring, and Maintenance Costs ControlNet Network ControlNet network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processor, PLC-5/40C processor, or PLC-5/80C processor 1794 FLEX I/O with 1793 FLEX Integra Remote I/O Network local computer with 1784-KTCX15 card Remote I/O remote rack PLC-5/40 laptop computer 1784-PCC PanelView operator interface 1771-ACN(R) SLC 5/03 processor with 1747-SN scanner module 1791-IOX 128-point block 1336 drive 1794 FLEX I/O with 1793 FLEX Integra 1794 FLEX I/O AC 32-point block 1747-AS 1400-PD power monitor display module 1794 FLEX I/O with 1793 FLEX Integra DeviceNet Network 1771-SDN scanner 1747-SDN scanner 1747-AS PanelView operator interface GK5 interface module DeviceNet network 1794 FLEX I/O with 1793 FLEX Integra 1784-PCD module host computer with DeviceNetManager software Compactlock I/O Armorlock MaXum I/O 1336 FORCE drive 1336 PLUS drive 1305 drive 41478

3 FLEX I/O and FLEX Integra Product Data Overview 3 2YHUYLHZ For information on See page 1794 FLEX I/O 3 About the FLEX I/O System 1793 FLEX Integra 4 )/(;,2FRQVLVWVRIWKUHHVSDFHVDYLQJFRPSRQHQWV DGDSWHUV WHUPLQDOEDVHXQLWV,2PRGXOHV Adapter Flexbus Connectors Terminal ase Keyswitch Flexbus Connector I/O Module 1794-I16 Remote I/O Connector Use the adapter to power the internal logic for as many as eight I/O modules and transfer the I/O data back to a PLC processor or a SLC processor via one of several available networks. Two separate connection terminals for field power let you daisy-chain power connections to adjacent terminal bases. Terminal Strips field power connection terminals (externally provided) Insert the terminal base into your system using the positive-locking flexbus connectors. Use a three-wire terminal base to wire directly to a two- or three-wire device. Terminate most of your wiring on the terminal base with almost no need for terminal blocks. Use the terminals to daisy-chain power connections to adjacent terminal bases, or connect individual power supplies to each base to isolate modules. Adjust the keyswitch to prevent incorrect module insertion into a preconfigured terminal base. Exchange terminal bases without moving other bases in your system Plug the I/O module into the terminal base. Use the module to connect to the I/O bus and field devices. Remove and insert a module without disturbing the field wiring, other I/O modules, or system power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

4 4 Overview FLEX I/O and FLEX Integra Product Data About the FLEX Integra System )/(;,QWHJUD,2FRQVLVWVRIDUDQJHRIGLJLWDODQGDQDORJPRGXOHVDOO FDSDEOHRIXVHZLWK)/(;,2DGDSWHUVDQGRWKHU)/(;,2 PRGXOHV(DFKPRGXOHLVDYDLODEOHZLWKHLWKHUVFUHZFDJHRU VSULQJFODPSZLUHWHUPLQDWLRQV TIP )/(;,QWHJUDPRGXOHVZHUHGHVLJQHGWRILWWRWKHULJKWRI \RXU)/(;,2PRGXOHV%HVXUHWRSODFH\RXU)/(;,QWHJUDPRGXOHVWRWKHULJKWRI\RXU)/(;,2PRGXOHV ZKHQGHVLJQLQJ\RXUV\VWHP Adapter Integra Modules Flexbus Connector Remote I/O Connector field power connection terminals (externally provided) Field wiring terminals Use the adapter to power the internal logic for as many as eight I/O modules and transfer the I/O data back to a PLC processor or a SLC processor via one of several available networks. Two separate connection terminals for field power let you daisy-chain power connections to adjacent FLEX I/O terminal bases. Insert the module into your system using the positive-locking flexbus connectors. Terminate all of your wiring on the module with no need for terminal blocks. Use the terminals to daisy-chain power connections to adjacent FLEX I/O terminal bases, or connect individual power supplies to each base to isolate modules. ATTENTION! 'RQRWUHPRYHDQ,QWHJUDPRGXOHXQGHUSRZHU 5HPRYLQJWKHPRGXOHXQGHUSRZHUZLOOEUHDNWKH HOHFWULFDOEDFNSODQHIOH[EXVFRQQHFWLRQV7KLVFDQ FDXVHSHUVRQDOLQMXU\RUSURSHUW\GDPDJHE\ VHQGLQJDQHUURQHRXVVLJQDOWR\RXUV\VWHP VILHOG GHYLFHVFDXVLQJXQLQWHQGHGPDFKLQHPRWLRQ FDXVLQJDQH[SORVLRQLQDKD]DUGRXVHQYLURQPHQW EUHDNLQJFRPPXQLFDWLRQVEH\RQGWKLVPRGXOH

5 FLEX I/O and FLEX Integra Product Data Overview 5 Mount and Remove Your System Easily <RXFDQKRUL]RQWDOO\RUYHUWLFDOO\PRXQWWKH)/(;,2V\VWHPDQG)/(;,QWHJUDPRGXOHVRQDVWDQGDUGPP',1UDLO7KHDGDSWHUDQG)/(;,2 WHUPLQDOEDVHHDVLO\VQDSRQWKH',1UDLOE\KDQG8VHDIODWEODGHVFUHZGULYHU WRUHPRYHFRPSRQHQWVIURPWKH',1UDLO 6FUHZKROHVDOORZ\RXWRKRUL]RQWDOO\RUYHUWLFDOO\SDQHOPRXQW\RXU)/(;, 2V\VWHPLQDQHQFORVXUH7RSDQHOPRXQW\RXU)/(;,2V\VWHPXVHWKH RSWLRQDOPRXQWLQJNLW10$QH[DPSOHRID',1UDLOPRXQWHG V\VWHPLVVKRZQEHORZ ATTENTION! :KHQSURSHUO\LQVWDOOHG)/(;,2DQG)/(;,QWHJUDDUH JURXQGHGWKURXJKWKH',1UDLOWRFKDVVLVJURXQG8VH ]LQFSODWHG\HOORZFKURPDWHGVWHHO',1UDLOWRDVVXUH SURSHUJURXQGLQJ8VLQJRWKHU',1UDLOPDWHULDOVHJ DOXPLQXPSODVWLFHWFZKLFKFDQFRUURGHR[LGL]HRUDUH SRRUFRQGXFWRUVFDQUHVXOWLQLPSURSHURULQWHUPLWWHQW SODWIRUPJURXQGLQJ0RXQW)/(;,QWHJUDRQO\RQ ]LQFSODWHG\HOORZFKURPDWHGVWHHO',1UDLO5HIHUWR 0RXQWLQJ'LPHQVLRQVDQG6SDFLQJ5HTXLUHPHQWVRQSDJH IRUPRUHLQIRUPDWLRQ FLEX I/O Connection Point DIN Rail A- part no. 199-DR1 DIN EN (35 x 7.5mm) Hook Screw holes for optional panel-mounting. Locking Lever DIN Rail Side View FLEX I/O adapters, terminal bases, and FLEX Integra modules are slotted to allow DIN-rail mounting. Remote I/O Connector A- part no Locking tab connector holds terminal base onto DIN rail :KHQ\RXXVH)/(;,2PRGXOHVLQDKLJKYLEUDWLRQLQVWDOODWLRQDQG SDUWLFXODUO\ZKHQPRXQWLQJWKHPRGXOHVYHUWLFDOO\ZHUHFRPPHQGXVLQJ ',1UDLOORFNV$OOHQ%UDGOH\SDUWQR($ ATTENTION! 7KHKRRNRQWKHWHUPLQDOEDVHDQGDGMDFHQWFRQQHFWLRQ SRLQWRQWKHDGDSWHUNHHSWKHWHUPLQDOEDVHVWLJKW WRJHWKHUVHHH[SORGHGYLHZDERYH7KHVHFRPSRQHQWVDUH FDSDEOHRIPDLQWDLQLQJDUHOLDEOHFRQQHFWLRQLQFDVHRI VKRFNDQGRUYLEUDWLRQ5HIHUWRWKHHQYLURQPHQWDO FRQGLWLRQVLQIRUPDWLRQLQHDFKPRGXOH VVSHFLILFDWLRQV

6 6 Overview FLEX I/O and FLEX Integra Product Data )/(;,QWHJUDPRGXOHVPRXQWRQWKH',1UDLO$IWHUWKHPRGXOHORFNV LQWRSODFHILUPO\SXVKWKH,QWHJUDPRGXOHLQWRWKHDGMDFHQWPRGXOHWR FRPSOHWHWKHEDFNSODQHFRQQHFWLRQ:KHQUHPRYLQJDQ,QWHJUD PRGXOHLQVHUWDIODWEODGHGVFUHZGULYHUEHWZHHQWKHPRGXOHVDQG WZLVWWXUQ7KHQUHOHDVHWKHORFNLQJOHYHUDQGUHPRYHWKHPRGXOH FLEX Integra Connection point Hook DIN rail A- pt. no. 199-DR1 (35 x 7.5mm) Locking lever DIN rail A A To remove: ATTENTION! 7KHKRRNRQWKHWHUPLQDOEDVHDQGDGMDFHQW FRQQHFWLRQSRLQWRQWKHDGDSWHUNHHSWKHWHUPLQDO EDVHVWLJKWWRJHWKHUVHHH[SORGHGYLHZDERYH 7KHVHFRPSRQHQWVDUHFDSDEOHRIPDLQWDLQLQJD UHOLDEOHFRQQHFWLRQLQFDVHRIVKRFNDQGRU YLEUDWLRQ5HIHUWRWKHHQYLURQPHQWDOFRQGLWLRQV LQIRUPDWLRQLQHDFKPRGXOH VVSHFLILFDWLRQV

7 FLEX I/O and FLEX Integra Product Data Overview 7 Design Your Configuration 2YHUYLHZ <RXFDQXVHDVPDQ\DVHLJKW)/(;,2DQGRU)/(;,QWHJUDPRGXOHV SHUDGDSWHU7KLVIOH[LELOLW\DOORZVDZLGHUDQJHRIGLJLWDODQGDQDORJ,2SRLQWVSHUDGDSWHU0L[DQGPDWFKGLJLWDODQGDQDORJ,2WRPHHW \RXUDSSOLFDWLRQQHHGV <RXFDQXVH)/(;,QWHJUDPRGXOHVZLWK)/(;,2PRGXOHV TIP 3ODFH,QWHJUDPRGXOHVWRWKHULJKWRI\RXU)/(;,2 PRGXOHVZKHQGHVLJQLQJ\RXUV\VWHP Any combination of FLEX I/O and/or FLEX Integra digital or analog modules. Adapter Eight terminal bases (maximum) The number of bases that make up an I/O group depends upon the adapter used Module 0 Module 1 Module 2 Module 3 Optional 1794-CE1 or 1794-CE3 Extender Cable Module 7 Module 6 Module 5 Module 4 Only 1 cable per system When using the optional extender cable, module groups are numbered sequentially along the length of the system. What this Product Data Contains 8VHWKHIROORZLQJWDEOHVWRILQGLQIRUPDWLRQLQWKLVWHFKQLFDOGDWD For Information On See Page Terminal ase Compatibility Cross-Reference Chart 17 Choosing the Correct Counter Module for Your Application 134 Related Publications 152 Mounting Dimensions and Spacing Requirements 154 Support, Training, and Repair Services 155

8 8 Overview FLEX I/O and FLEX Integra Product Data For Information On Catalog Number Description See Page Adapters 1794-ADN DeviceNet Adapter ACN15 ControlNet Adapter ACNR15 ControlNet Redundant Media Adapter AS2/C Remote I/O Adapter (to 2 modules) AS/D Remote I/O Adapter (to 8 modules) 15 Terminal ase Units 1794-T2 2-Wire Screw Clamp Terminal ase Unit T3 3-Wire Screw Clamp Terminal ase Unit T3S 3-Wire Spring Clamp Terminal ase Unit T3T Temperature Terminal ase Unit T3TS Spring Clamp Temperature Terminal ase Unit T3G Screw Clamp Grounded Terminal ase Unit T3GS Spring Clamp Grounded Terminal ase Unit TN Terminal ase Unit (NEMA-Style Screws) TNF Fused Terminal ase Unit (NEMA-Style Screws) F1 SCANport TM Terminal ase Unit AC 120V ac Modules 1794-IA8 120V ac 8 Input Module IA8I 120V ac 8 Isolated Input Module IA16 120V ac 16 Input Module OA8 120V ac 8 Output Module OA8I 120V ac 8 Isolated Output Module OA16 120V ac 16 Output Module V ac Modules 1794-IM8 220V ac 8 Input Module OM8 220V ac 8 Output Module DC Modules 1793-I4, -I4S 4 Sink Input Module I16, -I16S 16 Sink Input Module IV16, IV16S 16 Source Input Module O4P, -O4PS 4 Source Output (Protected) Module O16P, -O16PS 16 Protected Source Output Module OV16P, -OV16PS 16 Protected Sink Output Module I2XO2P, -I2XO2PS 2 Input/2 Protected Output Combo Module DC Modules 1794-I8 8 Sink Input Module I16 16 Sink Input Module IV16 16 Source Input Module O8 8 Source Output Module O16 16 Source Output Module O16P 16 Source Output (Protected) Module 75

9 FLEX I/O and FLEX Integra Product Data Overview OV16 16 Sink Output Module DC 1794-OV16P 16 Sink Output (Protected) Module O8EP Electronically Fused 8 Output Module I10XO6 10 Input/6 2A Output Combo Module 83 48V dc Modules 1794-IC16 48V dc 16 Sink Input Module OC16 48V dc 16 Source Output Module Analog Modules 1793-IE4, -IE4S 4 Input Analog Module OE2, -OE2S 2 Output Analog Module IE2XOE1, -IE2XOE1S 2 Input/1 Output Analog Combo Module Analog Modules 1794-IE8/ Selectable Analog 8 Input Module OE4/ Selectable Analog 4 Output Module IE4XOE2/ 4 Input/2 Output Analog Combo Module 103 Isolated Source Modules 1794-IF4I Source Isolated Analog 4 Input Module 108 Analog 1794-OF4I Source Isolated Analog 4 Output Module IF2XOF2I 2 Input/2 Output Isolated Analog Combo Module Relay Relay Module 1793-OW4, -OW4S 4 Relay Sink/Source Output Module Relay Relay Module 1794-OW8 8 Relay Sink/Source Output Module 120 Specialty RTD Input Module 1794-IR8 RTD Input Module 123 Thermocouple/RTD 1794-IRT8 Thermocouple/RTD Module 126 Input Module Thermocouple/mV Input 1794-IT8 Thermocouple/mV Module 129 Module SCANport Module 1203-FM1 SCANport Module 132 Counters Frequency Input Module 1794-IJ2 2 Input Frequency Module 135 Power Supply For Information On Catalog Number Description See Page Very High Speed Counter Module 2-Channel Pulse Counter Input Module 4-Channel Pulse Counter Input Module 1794-VHSC 2 Channels Very High Speed Counter Module (Used with 1794-ACN15 or ACNR15 only) 1794-ID2 2 Input Pulse Counter Module IP4 12/ 4 Input Pulse Counter Module 145 Power Supply 1794-PS13 Power Supply Module 148 Accessories Accessories 1794-CE1 Extender Cable, 0.3m (1ft) CE3 Extender Cable, 0.9m (3ft) NM1 Mounting Kit CJC2 Cold Junction Compensator Kit LL Label Kit 151 RSWire Software 151 AECAD Software

10 10 Adapter s Table of Contents FLEX I/O and FLEX Integra Product Data $GDSWHU VÃ7DEOHÃRIÃ&RQWHQWV 8VHWKHIROORZLQJWDEOHWRGHWHUPLQHZKLFKDGDSWHUZLOOPHHW\RXU DSSOLFDWLRQQHHGV Adapter Purpose See Page 1794-ADN 1794-ACN ACNR15 Connects up to 8 I/O modules to the DeviceNet network Connects the FLEX I/O system to the ControlNet network Connects the FLEX I/O system to the ControlNet network with optional redundant media capability AS2/C Connects the FLEX I/O system (up to 2 modules) to the Remote I/O network 1794-AS/D Connects the FLEX I/O system (up to 8 modules) to the Remote I/O network 14 15

11 FLEX I/O and FLEX Integra Product Data DeviceNet Adapter Cat. No ADN 11 9ÃGFÃ'HYLFH1HWÃ$GDSWHUÃ&DWÃ1RÃ$'1 Wiring DeviceNet Connector Connect To LK Wire -V LU Wire CAN 1 Low are Wire Drain WHT Wire CAN High RED Wire V 1 CAN = Controller Area Network ATTENTION! D E COM 24V :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ'Ã(Ã )ÃDQGÃ*ÃWRÃÃLQFKSRXQGV F G Specifications ADN I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 125k bit/s 250k bit/s 500k bit/s Indicators Mod/Net status - red/grn I/O status - red/grn Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac for 1s between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 7.6W 19.2V dc Thermal Dissipation V dc DeviceNet Power 90mA maximum Requirements DeviceNet Cable Allen-radley part no. 1485C-P1-Cxxx. Refer to publication DN-2.5 for more information. General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature 0 to 55 o C (32 to 131 o F) Storage Temperature -40 to 85 o C (-40 to 185 o F) Relative Humidity 5 to 95% noncondensing ShockOperating 30g peak acceleration, 11(±1)ms pulse width Non-operating 50g peak acceleration, 11(±1)ms pulse width Vibration Tested Hz per IEC Power Conductors Type Wire Size Category Publications Installation Instructions User Manual Agency Certification Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Groups IIC certified 127(7KHÃZLULQJÃODEHOÃRQÃWKHÃIURQWÃRIÃWKHÃPRGXOHÃVKRZVÃWKHÃFDEOHÃFRORUV 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity. &RQQHFWÃWKHÃ'HYLFH1HWÃFDEOHÃWRÃWKHÃUHPRYDEOHÃFRQQHFWRU,QVHUWÃFRQQHFWRUÃLQWRÃPDWLQJÃFRQQHFWRUÃRQÃ'HYLFH1HWÃDGDSWHUÃPRGXOH &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃWHUPLQDOÃ( &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃWHUPLQDOÃ' &RQQHFWLRQVÃ*ÃDQGÃ)ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃDQGÃFRPPRQÃWRÃWKHÃ QH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃUHTXLUHG 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃVZLWFKÃ%Ã9DOLGÃ VHWWLQJVÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃRUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃ QXPEHU

12 12 ControlNet Adapter Cat. No ACN15 FLEX I/O and FLEX Integra Product Data 9ÃGFÃ&RQWURO1HWÃ$GDSWHUÃ&DWÃ1RÃ$&1 Wiring A ATTENTION! F Network Access Port (NAP) :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ%Ã &Ã'ÃDQGÃ(ÃWRÃÃLQFKSRXQGV &RQQHFWÃWKHÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃWHUPLQDOÃ $Ã &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃ WHUPLQDOÃ% &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃ WHUPLQDOÃ& &RQQHFWLRQVÃ'ÃDQGÃ(ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃ(ÃDQGÃ 9ÃFRPPRQÃ'ÃWRÃWKHÃQH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃ UHTXLUHG C D E Specifications ACN15 I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 5M bit/s Supports Redundant No ControlNet Cabling Indicators Comm A - red/grn I/O Status - red/grn Programming Ports 1 RJ-45 Network Access Port (NAP) for use with ControlNet programming cable (e.g CP cable) Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 4.6W 19.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration ControlNet Cable Power Conductors Type Wire Size Category Publication Installation Instructions Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden RG-6/U Quad Shield Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max. 2 1 Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity. 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃ VZLWFKÃ)Ã9DOLGÃVHWWLQJVÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃ RUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃQXPEHU

13 FLEX I/O and FLEX Integra Product Data ControlNet Redundant Media Adapter Cat. No ACNR ÃGFÃ&RQWURO1HWÃ5HGXQGDQWÃ0HGLDÃ$GDSWHUÃ&DWÃ1RÃ$&15 Wiring A ATTENTION! G REDUNDANT MEDIA :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ&Ã 'Ã(ÃDQGÃ)ÃWRÃÃLQFKSRXQGV &RQQHFWÃWKHÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃ$Ã &RQQHFWÃWKHÃUHGXQGDQWÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃ % :KHQÃXVLQJÃWKHÃ$&15ÃDVÃDÃVLQJOHÃFKDQQHOÃXVHÃFKDQQHOÃ $ 15 Network Access Port (NAP) C D E F Specifications ACNR15 I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 5M bit/s Supports Redundant Yes ControlNet Cabling Indicators Comm A - red/grn (channel A) Comm - red/grn (channel ) I/O status - red/grn Programming Ports 1 RJ-45 Network Access Port (NAP) for use with ControlNet programming cable (e.g CP cable) Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 4.6W 19.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration ControlNet Cable Power Conductors Type Wire Size Category Operating Non-operating Publication Installation Instructions Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden RG-6/U Quad Shield Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max. 2 1 Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃ WHUPLQDOÃ' &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃ WHUPLQDOÃ& &RQQHFWLRQVÃ(ÃDQGÃ)ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃ)ÃDQGÃ 9ÃFRPPRQÃ(ÃWRÃWKHÃQH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃUHTXLUHG 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃ VZLWFKÃ*Ã9DOLGÃVHWWLQJÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃ RUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃQXPEHU 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

14 14 Remote I/O Adapter (up to 2 modules) Cat. No AS2/C FLEX I/O and FLEX Integra Product Data Remote I/O Adapter (up to 2 modules) Cat. No AS2/C Wiring The series C adapter can communicate with FLEX Integra analog modules. ATTENTION! When connecting wiring, torque terminal screws D, E, F, and G to 7-9 inch-pounds. Connect the remote I/O cable to the removable remote I/O connector. Connect input to the left side of the lower connector, terminal (. Connect 24V common to the left side of the upper connector, terminal '. Connections * and ) are used to pass power (G) and 24V common (F) to the next module in the series (if required). Make wiring connections as described in the installation instructions included with the module that mounts on your terminal base unit. This adapter module is shipped configured for standard addressing mode. In standard addressing mode, this module can be used as a replacement for 1794-AS2/A 2-slot Remote I/O adapters. The 1794-AS2/C adapter module can interface a maximum of 2 I/O modules. This adapter can be used in the mode that requires a unique location address for each I/O module and can also be used in a mode that allows duplicate addressing of I/O modules. Duplicate addressing of I/O modules allows the maximum amount of I/O in a system for a given amount of I/O image area. An input module can have the same location address as an output module because they complement each other. The input module uses only the input image area corresponding to the address. The output module uses only the output image area corresponding to the address. Description of Modes Addressing Module Placement Rules Type Standard 2 terminal bases per adapter Each terminal base represents 1 I/O group Compact 16-point addressing 1 SH2 Compact 8-point addressing digital modules 2 terminal bases per adapter Each module represents 1/2 of an I/O group 2 modules represent 1 I/O group Do not place the 1794-I8 next to an output module. If this combination is used the AS will fault. D E COM 24V Legal Module Placements Any module in any slot A 16-point input module and a 16-point output module in an I/O group Not applicable F G Description of Modes (continued) Compact Not applicable Not applicable 8-point addressing analog modules Complementary 16-point addressing Complementary 8-point addressing 2 terminal bases per adapter 2 modules, 1 in primary, and 1 in complement represent 1 I/O group 2 terminal bases per adapter 4 modules, 2 in the primary and 2 in the complement, represents 1 I/O group Any module in any I/O position of the primary chassis, input modules complemented by output modules, analog modules complemented by analog modules or empty base 2 inputs in a group complemented by 2 outputs 2 outputs in a group complemented by 2 inputs 2 block transfer modules complemented by 2 empty slots 1 block transfer module and 1 input in a group complemented by 1 empty slot and 1 output module Specifications AS2/C The 1794-AS2/C adapter cannot be used with PLC-2 processors. I/O Capacity 2 modules Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 57.6, 115.2, 230.4k bit/s Indicators Adapter active - green Adapter fault - red, Local fault - red Flexbus Output Current 640mA maximum Isolation Voltage 500V ac between user power and flexbus Power Consumption 450mA maximum from external 24V supply Power Dissipation 4.6W 31.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Remote I/O Cable Power Conductors Wire Size Category Publication Installation Instructions User Manual Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden 9463 or equivalent as specified in A- Approved Vendor List, publication ICCG-2.2 A- pin connector part no gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

15 FLEX I/O and FLEX Integra Product Data Remote I/O Adapter (up to 8 modules) Cat. No AS/D 15 Remote I/O Adapter (up to 8 modules) Cat. No AS/D Wiring The series D adapter can communicate with FLEX Integra analog modules. ATTENTION! When connecting wiring, torque terminal screws D, E, F, and G to 7-9 inch-pounds. Connect the remote I/O cable to the removable remote I/O connector. Connect input to the left side of the lower connector, terminal (. Connect 24V common to the left side of the upper connector, terminal '. Connections * and ) are used to pass power (G) and 24V common (F) to the next module in the series (if required). Make wiring connections as described in the installation instructions included with the module that mounts on your terminal base unit. The 1794-AS adapter module can interface a maximum of 8 I/O modules. This adapter can be used in the mode that requires a unique location address for each I/O module and can also be used in a mode that allows duplicate addressing of I/O modules. Duplicate addressing of I/O modules allows the maximum amount of I/O in a system for a given amount of I/O image area. An input module can have the same location address as an output module because they complement each other. The input module uses only the input image area corresponding to the address. The output module uses only the output image area corresponding to the address. Description of Modes Addressing Module Placement Rules Type Standard 8 terminal bases per adapter Each terminal base represents 1 I/O group Compact 16-point addressing 1 SH2 Compact 8-point addressing digital modules 8 terminal bases per adapter Each module represents 1/2 of an I/O group 2 modules represent 1 I/O group 8 modules = 1/2 I/O rack 8 terminal bases per adapter Each module represents 1/4 of an I/O group 4 modules represent 1 I/O group Do not place the 1794-I8 next to an output module. If this combination is used the AS will fault. D E COM 24V Legal Module Placements Any module in any slot A 16-point input module and a 16-point output module in an I/O group Two 8-point input modules and two 8-point output modules in an I/O group Module type must alternate within an I/O group: input, output, etc. F G Description of Modes (continued) Compact 8-point addressing analog modules Complementary 16-point addressing Complementary 8-point addressing 8 terminal bases per adapter Two block transfer modules Each module and adjacent and their adjacent empty base empty base represents 1/2 of = 1 I/O group - An empty slot an I/O group must accompany each block transfer module in 8-point compact addressing 8 terminal bases per adapter 2 modules, 1 in primary, and 1 in complement represent 1 I/O group 8 terminal bases per adapter 4 modules, 2 in the primary and 2 in the complement, represents 1 I/O group Any module in any I/O position of the primary chassis, input modules complemented by output modules, analog modules complemented by analog modules or empty base 2 inputs in a group complemented by 2 outputs 2 outputs in a group complemented by 2 inputs 2 block transfer modules complemented by 2 empty slots 1 block transfer module and 1 input in a group complemented by 1 empty slot and 1 output module Specifications AS/D The 1794-AS/D adapter cannot be used with PLC-2 processors. I/O Capacity 8 modules Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 57.6, 115.2, 230.4k bit/s Indicators Adapter active - green Adapter fault - red, Local fault - red Flexbus Output Current 640mA maximum Isolation Voltage 500V ac between user power and flexbus Power Consumption 450mA maximum from external 24V supply Power Dissipation 4.6W 31.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration Remote I/O Cable Power Conductors Wire Size Category Operating Non-operating Publication Installation Instructions User Manual Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden 9463 or equivalent as specified in A- Approved Vendor List, publication ICCG-2.2 A- pin connector part no gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

16 16 FLEX I/O Terminal ase Unit s Table of Contents FLEX I/O and FLEX Integra Product Data )/(;Ã,2Ã7HUPLQDOÃ%DVHÃ8QLW VÃ7DEOHÃRIÃ&RQWHQWV 8VHWKHIROORZLQJWDEOHWRGHWHUPLQHZKLFK)/(;,2WHUPLQDOEDVH XQLWZLOOPHHW\RXUDSSOLFDWLRQQHHGV Terminal ase Purpose See Page 1794-T2 A generic version of the 1794-T3 below T T3S 1794-T3T Primarily intended for use with input modules when using 3-wire input proximity switches - can also be used with output modules A spring clamp version of the cage clamp 1794-T3 above - provides faster, simpler wire installation Required with the 1794-IT8 module (when used in thermocouple mode) - also provides chassis ground connections for the 1794-IR8 and analog modules T3TS A spring clamp version of the 1794-T3T T3G A screw clamp terminal base unit with individual grounding used with certain analog modules T3GS A spring clamp version of the 1794-T3G TN 1794-TNF Provides screw terminals to accept larger gauge wires plus cover for I/O wiring Provides 8 5x20mm fuses, screw terminals, plus a cover for I/O wiring - shipped with fuses for the 1794-OA8 module; can be used to fuse the 1794-OM8 and -OW8 modules with a replacement fuse (see the installation instructions) F1 Required with the 1203-FM1 module 29

17 FLEX I/O and FLEX Integra Product Data FLEX I/O Terminal ase Compatibility Cross-Reference 17 )/(;Ã,2Ã7HUPLQDOÃ%DVHÃ&RPSDWLELOLW\Ã&URVV5HIHUHQFH 7KHIROORZLQJWDEOHLOOXVWUDWHVWKHUHFRPPHQGHG)/(;,2WHUPLQDOEDVH XQLWVIRUHDFKPRGXOH0DQ\WHUPLQDOEDVHXQLWVFDQEHXVHGZLWKPRVW PRGXOHVEXWDX[LOLDU\WHUPLQDOVWULSVPD\EHUHTXLUHG FLEX I/O Product Catalog Number Recommended ase Compatible ase(s) AC 120V ac Modules 1794-IA IA8I TN T3 T3S T2 TN T3 T3S T IA OA8 T3 T3S TN Auxiliary terminal strips are required when using the TN for the IA16 TNF T3 T3S TN T OA8I TNF T3 T3S TN T2 220V ac Modules 1794-OA IM OM8 T3 T3S T2 TN TN None Auxiliary terminal strips are required when using the TN for the OA16 TN TNF DC Modules 1794-I8 T3 T3S 1794-I16 T3 T3S 1794-IV16 T2 T3 T3S 1794-O8 T2 T3 T3S 1794-O16 T2 T3 T3S 1794-O16P T2 T3 T3S 1794-OV16 T3 T3S 1794-OV16P T3 T3S

18 18 FLEX I/O Terminal ase Compatibility Cross-Reference FLEX I/O and FLEX Integra Product Data FLEX I/O Product Catalog Number Recommended ase Compatible ase(s) DC Modules 1794-O8EP 1794-I10XO6 T3 T3S TN T2 T3 T3S 48V dc Modules 1794-IC16 T3 T3S 1794-OC16 T3 T3S T2 Analog Modules 1794-IE8/ T3 T3S T2 T3T T3TS 1794-OE4/ T3 T3S T2 T3T T3TS TN 1794-IE4XOE2/ T3 T3S T2 T3T T3TS Isolated Analog Source Modules 1794-IF4I T3 T3S T2 T3T T3TS TN 1794-OF4I T3 T3S T2 T3T T3TS TN 1794-IF2XOF2I T3 T3S T2 T3T T3TS TN Relay Relay Module 1794-OW8 TNF T3 T3S T2 TN Specialty RTD Input Module 1794-IR8 T3 T3S T2 T3T T3TS Thermocouple/RTD Input Module 1794-IRT8 T3G T3GS Thermocouple/mV Input Module SCANport Module 1794-IT FM1 T3T T3 T3S T2 T3TS You can use a T2, T3, or T3S for mv inputs only. F1 Counter Frequency Input Module 1794-IJ2 T3G T3GS Very High Speed Counter Module 1794-VHSC T3G T3GS For use with 1794-ACN(R)15 only. 2 Channel Pulse Counter Input Module 4 Channel Pulse Counter Input Module 1794-ID IP4 T3 T3S TN TNF T3 T3S TN TNF Auxiliary terminal strips are required when using the TN or TNF for the ID2 Auxiliary terminal strips are required when using the TN or TNF for the IP4

19 FLEX I/O and FLEX Integra Product Data 2-Wire Screw Clamp Terminal ase Unit Cat. No T2 19 :LUHÃ6FUHZÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% 1794-T2 A 0-15 COM COM V V C 34 & 51 V =, 120V ac, or 48V dc COM = common, 120V ac common, or 48V dc common A - 0 through through 33 C - 34 and 51 ATTENTION! Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply or 120V ac 1794-T2 Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Combination Daisy-chain and Separate Power Supply Specifications T2 Number of Terminals 1 row of 16 1 row of 18 1 row of 2 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

20 20 3-Wire Screw Clamp Terminal ase Unit Cat. No T3 FLEX I/O and FLEX Integra Product Data :LUHÃ6FUHZÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% 1794-T3 A - 0 through through 33 C - 34 through 51 ATTENTION! COM V COM V V =, 120V ac, or 48V dc COM = common, 120V ac common, or 48V dc common Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply or 120V ac 1794-T3 Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A. A C Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Combination Daisychain and Separate Power Supply Specifications T3 Number of Terminals 1 row of 16 2 rows of 18 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

21 FLEX I/O and FLEX Integra Product Data 3-Wire Spring Clamp Terminal ase Unit Cat. No T3S 21 :LUHÃ6SULQJÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% T3S Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring A C Combination Daisychain and Separate Power Supply Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method A - 0 through through 33 C - 34 through 51 ATTENTION! Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply 1794-T3S Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Note: All modules powered by the same power supply must be analog modules for this configuration. Total current draw through any base unit must not be greater than 10A Specifications T3S Number of Terminals 1 row of 16 2 rows of 18 Terminal Type Spring-clamp - To open, insert bladed screwdriver ( in/ mm) and lift up. Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum, 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum (Established by inserted module.) or 120V ac Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

22 22 Screw Clamp Temperature Terminal ase Unit Cat. No T3T FLEX I/O and FLEX Integra Product Data 6FUHZÃ&ODPSÃ7HPSHUDWXUHÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% T3T The temperature terminal base has connections for cold junction compensation, and 8 terminals designated for shield termination to chassis ground. Wiring 1794-T3T Terminal ase Unit Channel High Sig () Low Sig (-) Sig Ret Reserved Shld Ret (C) 18(N0) (C) 20(N1) (C) 22(N2) (C) 24(N3) (C) 26(N4) (C) 28(N5) (C) 30(N6) (C) 32(N7) 46 Common 16, 17, 19, 21, 23, 25, 27, 29, 31, and 33 power 34, 35, 50, and 51 Terminals and are used with cold junction compensators only. 1 Terminals are chassis ground. ATTENTION! Daisy-chaining Using Adapter Power Supply C C N0 C N1 C N2 C N3 C N4 C N5 C N6 C N7 C V C J C C J C V = chassis ground V = N = add. input C = common CJC = cold junction compensation RWDOÃFXUUHQWÃGUDZÃWKURXJKÃWKHÃWHUPLQDOÃEDVHÃXQLWÃLVÃ OLPLWHGÃWRÃ$Ã6HSDUDWHÃSRZHUÃFRQQHFWLRQVÃPD\ÃEHÃ QHFHVVDU\ 'RÃQRWÃGDLV\ÃFKDLQÃSRZHUÃRUÃJURXQGÃIURPÃWKHÃ WKHUPRFRXSOHÃWHUPLQDOÃEDVHÃXQLWÃWRÃDQ\ÃDFÃRUÃGFÃ GLJLWDOÃPRGXOHÃWHUPLQDOÃEDVHÃXQLW 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHÃDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH thermocouple or analog module thermocouple or analog module A thermocouple or analog module C Note: All modules must be analog or thermocouple modules for this configuration. Use this method when wiring all analog modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A thermocouple or analog module Daisy-chaining with a Separate Power Supply Specifications T3T Number of Terminals 1 row of 16; 2 rows of 18 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Ch-to-ch isolation determined by inserted mod General Specifications Dimensions (w/mod in base) 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration Conductors, 48V dc or 120V ac Use this method when mixing digital modules and analog modules and total current draw through terminal base units is greater than 10A. Individually Powered from Separate Power Supply Combination Daisychain and Separate Power Supply Operating Non-operating Wire Size discrete module Category Publication Installation Instructions Agency Certification thermocouple or analog module discrete module Thermocouple module wiring separate from discrete wiring Note: Use this configuration if using any noisy dc discrete I/O modules in your system. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method thermocouple or analog module thermocouple or analog module thermocouple or analog module 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum (Established by inserted module.) 1 discrete module thermocouple or analog module Note: All modules must be analog modules in this configuration. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method or 120V ac Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Note: All modules powered by the same power supply must be analog modules for this configuration. Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.

Analog I/O Module Summary

Analog I/O Module Summary 36 Select FLEX I/O Modules Analog I/O Module Summary Catalog Number Inputs Outputs Terminal Base Unit Module Type 1794-IE8 8 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, Selectable, non-isolated inputs 1794-IE8XT

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

24V dc Analog Block I/O Module

24V dc Analog Block I/O Module 24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

Allen-Bradley Automation

Allen-Bradley Automation FLEX Integra I/O (atalog Number 793) Product Data 4868 4869 Flexible, inexpensive, and compact. FLEX Integra is a flexible, low-cost, small increment, modular I/O system for distributed applications that

More information

CompactLogix 5370 L3 Control System

CompactLogix 5370 L3 Control System CompactLogix 5370 Controllers CompactLogix 5370 L1 Control System CompactLogix 5370 L2 Control System CompactLogix 5370 L3 Control System CompactLogix 5370 controllers provide scalable controller solutions

More information

FLEX I/O Frequency Input Module. Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT User Manual

FLEX I/O Frequency Input Module. Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT User Manual FLEX I/O Frequency Input Module Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

1769 Compact I/O Modules Specifications

1769 Compact I/O Modules Specifications Technical Document 1769 Compact I/O Modules Specifications Catalog Numbers 1769 Series Topic Page Summary of Changes 2 I/O Module Overview 2 Place Compact I/O Modules 4 Digital I/O Modules 5 Analog I/O

More information

XM Monitoring Modules Specifications

XM Monitoring Modules Specifications Technical Data XM Monitoring Modules Specifications Catalog Numbers 1440 series The XM series of intelligent I/O modules process, in real-time, the critical parameters used to assess the current health

More information

FOUNDATION Fieldbus Junction Box

FOUNDATION Fieldbus Junction Box Installation Instructions FOUNDATION Fieldbus Junction Box Catalog Number 1788-FBJB4R, 1788-FBJB6 Topic Page Important User Information 2 About the Junction Boxes 3 Additional Resources 3 Installation

More information

1769 Compact I/O Modules Specifications

1769 Compact I/O Modules Specifications Technical Data 1769 Compact I/O Modules Specifications Catalog Numbers 1769 series Topic Page Available 1769 I/O Modules 4 Digital I/O Modules 6 Analog I/O Modules 7 Specialty I/O Modules 8 Module Specifications

More information

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

SLC 500 System Overview

SLC 500 System Overview SLC 500 System Overview The Allen-Bradley SLC 500 is a small chassis-based family of programmable controllers, discrete, analog, and specialty I/O, and peripheral devices. The SLC 500 family delivers power

More information

FLEX Ex Power Supplies

FLEX Ex Power Supplies Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Installation Instructions

Installation Instructions Installation Instructions ControlNet Modular Repeater Dual Copper Module Catalog Number This document describes how to install and apply the dual copper repeater module. Topic: Page: Important User Information

More information

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection

More information

Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC) Allen-Bradley Spares

Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC) Allen-Bradley Spares 1 Allen-Bradley Very High Speed Counter Module User Manual (Cat. No. 1794-VHSC) Allen-Bradley Spares Important User Information Because of the variety of uses for the products described in this publication,

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

SLC 500 RTD/Resistance Input Modules

SLC 500 RTD/Resistance Input Modules Technical Data SLC 500 RTD/Resistance Input Modules (Catalog Numbers 1746-NR4 and 1746-NR8) 1746-NR4 1746-NR8 Inside................... page Hardware Overview............. 2 Module Operation..............

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

FLEX Ex V ac In/Quad-Ex dc Out Power Supply Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic

More information

- 1. Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC)

- 1. Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC) - 1 Allen-Bradley Very High Speed Counter Module User Manual (Cat. No. 1794-VHSC) Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

Modicon Momentum automation platform 0

Modicon Momentum automation platform 0 Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

FP-RTD-122. Features OPERATING INSTRUCTIONS. 8-Channel, 3-Wire RTD and Resistance Input Module

FP-RTD-122. Features OPERATING INSTRUCTIONS. 8-Channel, 3-Wire RTD and Resistance Input Module OPERATING INSTRUCTIONS FP-RTD-122 8-Channel, 3-Wire RTD and Resistance Input Module These operating instructions describe the installation, features, and characteristics of the FP-RTD-122. For details

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

5069 Compact I/O Modules Specifications

5069 Compact I/O Modules Specifications Technical Data 5069 Compact I/O Modules Specifications Digital I/O Module Catalog Numbers 5069-IB16, 5069-IB16F, 5069-IB6F-3W, 5069-OB16, 5069-OB16F, 5069-OW4I, 5069-OX4I Analog I/O Module Catalog Numbers

More information

Allen-Bradley. User Manual. SLC 500 Analog I/O Modules. (Cat. Nos NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V)

Allen-Bradley. User Manual. SLC 500 Analog I/O Modules. (Cat. Nos NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V) Allen-Bradley SLC 500 Analog I/O Modules (Cat. Nos. 1746-NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V) User Manual Important User Information Because of the variety of uses for the products described in this

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Allen-Bradley Spares

Allen-Bradley Spares FLEX Ex Technical Data 1797 Series Intrinsically Safe I/O Distributed Architecture FLEX Ex TM is a modular I/O system that mounts directly to the controlled equipment in the hazardous area This eliminates

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix

12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix Installation Instructions 12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix Cat. No. 1799-D12G12GL Inside... For See page About the Module 1 Important User

More information

UniStream Uni-I/O Modules

UniStream Uni-I/O Modules UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,

More information

ControlNet Accessory Specifications

ControlNet Accessory Specifications Technical Data ControlNet Accessory Specifications Catalog Numbers 1786-RPA,, 1786-RPFM, 1786-RPFS, 1756-RPFRL, 1786-PRFRXL Topic Page 1786-RPA/B ControlNet Modular Repeater Adapter 2 ControlNet Dual Copper

More information

This Errata Sheet contains corrections or changes made after the publication of this manual.

This Errata Sheet contains corrections or changes made after the publication of this manual. Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL4 Date: September 12, 218 Manual Number D4-ANLG-M Revision and Date th Ed., Rev.

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

1769 Compact Discrete Input/Output Modules

1769 Compact Discrete Input/Output Modules Technical Data 1769 Compact (Bulletin 1769) &RPSDFW,2LVDQHZ3/&VW\OHSODWIRUPRIIHULQJLQGXVWU\OHDGLQJSULFHDQG SHUIRUPDQFH,WXWLOL]HVWKHODWHVWGHVLJQWHFKQRORJ\IRUVXSHULRUSHUIRUPDQFH H[FHOOHQWIXQFWLRQDOLW\DQGHDVHRIXVH

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis Table of Contents The Allen-Bradley Servo Interface Module (Cat. No. 1771-SF1) when used with the Micro Controller (Cat. No. 1771-UC1) can control single axis positioning systems such as found in machine

More information

F4-08RTD 8-Channel RTD Input

F4-08RTD 8-Channel RTD Input F-8RTD 8-Channel RTD 92 F8RTD 8-Channel RTD Module Specifications The F8RTD 8 Differential Channel RTD module provides several features and benefits. It provides eight RTD input channels with 16-bit resolution.

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

Compact I/O RTD/Resistance Input Module

Compact I/O RTD/Resistance Input Module User Manual Compact I/O RTD/Resistance Input Module Catalog Number 1769-IR6 Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment.

More information

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation MAN0095-15-EN HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation 1 DESCRIPTION The Horner APG High Resolution Thermocouple Input Module allows thermocouple temperature

More information

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS 4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility

More information

FLEX Ex Thermocouple/RTD Input Module

FLEX Ex Thermocouple/RTD Input Module Installation Instructions FLEX Ex Thermocouple/RTD Input Module Catalog Number 1797-IRT8 Contents For Information About See Page Important User Information 2 Module Installation 3 Installation in Zone

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN

SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN 1. SPECIFICATIONS / DIMENSIONS ANALOG OUT Number of Outputs 8 (207) or 4 (107)

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module June 2017 The PACSystems Universal Analog Input module IC695ALG600 provides eight general purpose input channels and two Cold Junction Compensation (CJC) channels. Inputs are divided into two equal groups

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX-1329 AC/DC COUPLING TERMINAL BLOCK INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

SLC 500 Thermocouple/mV Analog Input Module

SLC 500 Thermocouple/mV Analog Input Module SLC 500 Thermocouple/mV Analog Input Module 1746-NT8 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

ControlNet Ex Tap Terminator Installation Instructions

ControlNet Ex Tap Terminator Installation Instructions Installation Instructions Tap Terminator Installation Instructions (Cat No 1797-TCAP) Use this document as a guide when you install a ControlNet TM Ex tap terminator This document will be packaged with

More information

2750 Integra Mainframes

2750 Integra Mainframes Selector Guide Plug-In Modules for 700, 70, 70 Integra Mainframes Module Selector Guide This selector guide may prove helpful in identifying the best module for a specific application. Install up to five

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

DeviceNet Connector. Address Switches. Diagnostic LEDs. I/O Connectors. Power Connectors

DeviceNet Connector. Address Switches. Diagnostic LEDs. I/O Connectors. Power Connectors DeviceNet piconet Stations TURCK s piconet DeviceNet stations are compact rugged stations designed for machine mounting. These stations allow easy connection of standard I/O devices such as sensors, limit

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short

More information

Power Supplies. SCL Series. Features. Related Products. Applications

Power Supplies. SCL Series. Features. Related Products. Applications SDN Series The SDN family of DIN Rail power supplies have industry leading performance with a true industrial grade design and high quality that meets difficult industrial environmental conditions including

More information

SensorLex 8B Isolated Analog Signal Conditioning Products. and D power. 7 to 34VDC 36V TVS, 1A Fuse, OV detection 35.5V max 6.

SensorLex 8B Isolated Analog Signal Conditioning Products. and D power. 7 to 34VDC 36V TVS, 1A Fuse, OV detection 35.5V max 6. Accessories for 8B Analog Modules Features Single Channel DIN Rail Mounting Accessory 2-, 4-, 8-, 16-Position Backpanels Panel or DIN Rail Mounting Options 19-Inch Mounting Rack for Backpanels Interface

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Allen-Bradley. User Manual. SLC 500 Thermocouple/mV Analog Input Module. (Catalog Number 1746-NT8)

Allen-Bradley. User Manual. SLC 500 Thermocouple/mV Analog Input Module. (Catalog Number 1746-NT8) Allen-Bradley SLC 500 Thermocouple/mV Analog Input Module User Manual (Catalog Number 1746-NT8) Important User Information Because of the variety of uses for the products described in this publication,

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application

More information

Analog Modules AS-i IP20

Analog Modules AS-i IP20 (Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage

More information

SISNet Distance Extenders

SISNet Distance Extenders April 2011 Page 1 Extend the DeltaV SIS remote peer ring with Dedicated safety communications Full communications redundancy Flexibility to meets project needs Consistent update rate Introduction The DeltaV

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information