1 Report 201 / , R. Wedberg, K. Gajewski Department of Physics and Astronomy P.O. Box 516 SE Uppsala Sweden Papers in the FREIA Report Series are published on internet in PDF- formats. Download from
2 Itelco-Electrosys 400 kw RF Station Site Acceptance Test M. Jobs, R. Wedberg, K. Gajewski, Uppsala, Sweden FREIA Figure 1. Installed Itelco-Electrosys 400 kw Station at FREIA Abstract The manufactured and delivered Itelco-Electrosys 400 kw RF station was tested on site at FREIA, in Uppsala August 31 through September The station could successfully deliver continuous pulsetrains with a power-level up to 400 kw. Each of the stations 200 kw tetrode based amplifier sections were mounted with TH-595 tetrode tubes from Thales and tuned for optimal performance. The gain of the tetrode amplifiers were roughly 15 db with some variation between the two amplifier sections and the overall gain was approximately 85 db maximum. Some droop and phase distortion on the combined output pulse was measured caused primarily by a limited response time of the screen-grid power supply. - 1 / 35 -
3 1. 0Introduction The following section includes some general characteristics and remarks. The data presented within this report provides the test results for acceptance of the Site Acceptance Test of the Itelco-Electrosys RF - station. 1.1 General station characteristics 1. Dimensions of the power station: 4884 mm long 1158 mm width 2550 mm high (incl.combiner) 2. Documentation: Massive 3 folders. 1.2 Response to FAT remarks The following remarks were made during factory acceptance test and have now been responded to 1. One series switch has to be replaced, broken a. Series switch replacement provided by Astrol and installed on site 2. Complete test for EMC/CE compliance are to be done before shipping and must have passed acceptance values before shipping a. Full EMC/CE documentation provided 3. Elimination of software small bugs found during test a. Multiple bugs removed and corrected, see Section Full control via EPICS (some parameters setting by remote is not available in the current software version) a. Remote interface updated, See section Synchronization of history log data-base via SNMP a. Remote interface updated, See section The station emergency stop must be equipped with under-voltage protection. At the time of the test the power supply for the emergency switch had broken and stopped all functionality in the emergency switch. The station should not be able to run if the emergency stop is not working. a. Station installed with properly functioning emergency switch 7. The ability to remotely enable/disable the driver gain control feedback loop. The drivers has a built in gain feedback loop with a few seconds settling time which might interfere with any external feedback loops used to control the station. If this would be the case it must be possible to disable the internal loops to gain full control of the station. a. AGC is now available to enable/disable at will 8. When running at 28 Hz the stations internal power measurement shows a discrepancy in the measured values. When outputting 200 kw 1 ms pulses the stations measured value was roughly 150 kw. It was theorized that this might be related to the short pulse duration and would be further investigated by Electrosys. a. Internal component values updated by Itelco-Electrosys to solve issue - 2 / 35 -
4 2. 0Key Parameters Tender Comparison The following list describes the correspondence of the measured station parameters during the on-site acceptance test and its correspondence with those specified in the tender. Green markings indicate better or equal to tender specifications, yellow indicate slight deviation and red indicate major deviations. Parameter Tender Specification HPA1 HPA2 Station Out Frequency of operation MHz MHz MHz Output power 175 kw 200 kw 200 kw 3 db bandwidth 250 khz 2.5 MHz 2.5 MHz Pulse width 3.5 ms 3.5 ms 3.5 ms Frequency of pulses 14 Hz 14 Hz 14 Hz Input power from driver 10 kw 6.0 kw 6.9 kw Gain 14.5 db 15.6 db 14.9 db Anode Efficiency 65 % 65% 60% Class of operation AB AB AB Harmonics < -35 dbc < -40 dbc Spurious < -60 dbc < -60 dbc Linearity 1 ± 0.5 db ± 1.25 db ± 1.25 db ± 1.25 db Gain amp. stability (time >5 μs) ± 1 db ± 0.3 db Gain phase stability (time >5 μs) ± 5degrees ± 1.5 degrees Driver Gain 2 70 db 69.5 db 70 db Driver amp. stability (time >5 μs) 3 ± 0.2 db ± 0.25 db ± 0.1 db Driver Phase Linearity ± 5degrees 1: Primarily caused by deviation in linearity in the <50 kw range 2: Controlled by station, could be modified by if required 3: Some minor discrepancy of gain control in HPA1 ± 0.5 degrees - 3 / 35 -
5 3. 0Power Supplies The RF station power supplies were thoroughly evaluated as part of the on-site acceptance test. The performance both during idle operation as well as in the output power range 40kW to 400kW were recorded and are presented in the following sections. 3.1 Station Idle Set Values After mounting of the two tetrode tubes the screen and control grid supplies were set for class AB operation. The bias of the control grid voltages were set so that the idle anode currents were 40mA. The input water flow and pressure as well as the serial numbers of the tetrode tubes were recorded and are given below. The main tests were performed using 3.5 ms long pulses at 14 Hz repetition rate and the carrier frequency was set to MHz. Pulse Settings: 3.5 ms 14 Hz Carrier Freq: MHz Power Supplies Idle Control Grid Voltage [V] HPA1 HPA2 Screen Grid Voltage[V] HPA1 HPA2 Operating Voltage Operating Voltage Blanking Voltage Cooling Water: Water Conduct. Water Flowrate [l/min] Pressure [bar] Average [μs/cm] 0,4 Station In 195 Station In 2,55 Log Exist Load In 60 Station Out 0,35 Water Temp [Celsius] HPA1 HPA2 Water Temp [Celsius] Station In Load In 21,3 Station Out Load Out 24,8 Tube A Serial Nr: Tube B Serial Nr: / 35 -
6 3.2 Supplies Station Read Values The following values were recorded using the stations built in current and voltage meters at a total output power ranging from 40 kw to 400 kw. These should be read in comparison with the actual measured voltages given in Section 3.3 and 3.4. HPA1 Station P. Out [kw] I_anode [I] 4,93 6,98 8,66 10,1 11,35 12,55 13,47 14,52 15,87 17,46 V_anode [kv] 16,3 16,28 16,33 16,33 16,38 16,38 16,43 16,43 16,45 16,5 Filament Current [I] Filament Voltage [V] G1 Current [I] 0 0,03 0,15 0,32 0,47 0,63 0,73 0,89 1,13 1,52 G1 Voltage [V] G2 Current [I] 0,023 0,03 0,072 0,08 0,096 0,117 0,14 0,175 0,24 0,357 G2 Voltage [V] HPA2 Station P. Out [kw] I_anode [I] 4,88 6,95 8,59 10,08 11,35 12,5 13,62 14,62 15,79 17,31 V_anode [kv] 17,14 17,16 17,21 17,24 17,26 17,28 17,31 17,33 17,36 17,38 Filament Current [I] Filament Voltage [V] G1 Current [I] 0 0,05 0,22 0,41 0,58 0,74 0,92 1,1 1,35 1,78 G1 Voltage [V] G2 Current [I] 0,026 0,062 0,073 0,083 0,097 0,12 0,155 0,197 0,264 0,415 G2 Voltage [V] / 35 -
7 3.3 Control Grid Voltage and Current The voltage and current variation of both the control grid supplies were measured during the pulse for the complete power range of 40 kw to 400 kw. In order to measure the voltage and current of the control grid power supplies a Rigol DS4054 scope was connected to the stations BNC connectors included for measurements of control grid voltages and currents. A drop in voltage as a function of increased output power can be seen in Fig. 2 and Fig.3. However, the response time of the control grid supplies seems adequate as only a minor initial drop of control grid voltage is visible when the RF pulse is applied at full power. Figure 2. HPA1 control grid voltage as a function of total output power. Figure 3. HPA2 control grid voltage as a function of total output power. - 6 / 35 -
8 The measured current over the control grid supplies shows an increase in grid current in the initial 1 ms of the output pulse at full (400 kw) power. This is, however, not currently thought of as being attributed to the performance of the control grid supply. The variation in grid current is instead thought of as being an effect of the limited response time of the screen grid power supply (see Section 3.4). Figure 4. HPA1 control grid current as a function of total output power. Figure 5. HPA2 control grid current as a function of total output power. - 7 / 35 -
9 3.4 Screen Grid Voltage The screen grid power supplies were measured in the power range of 40 kw to 400 kw. The measurements seen in Fig. 6 through Fig. 10 show that the screen grid supply experience an initial droop. This indicates that the response time of the screen grid power supplies is long enough to cause distortion of the output pulse. As is presented in Section 4.4 and section 4.8 this causes a distortion on both the amplitude of the output signal as well as a phase-shift. Figure 6. HPA1 screen grid voltage as a function of total output power. Figure 7. HPA2 screen grid voltage as a function of total output power. - 8 / 35 -
10 In order to be able to measure the output current of the screen grid power supply direct probing of the built-in measurement boards were necessary. No external BNC connectors for voltage or current measurements were available on the station. For voltage measurements a high-voltage T-connection were connected to a high-impedance, high-voltage probe placed between the power supply and the tetrode cavity screen voltage connector. Fig. 8 shows the probe location on the board for measuring the screen-grid current. Figure 8. Current measurement probe location on board. - 9 / 35 -
11 Figure 9. HPA1 screen grid current as a function of total output power. Figure 10. HPA2 screen grid current as a function of total output power / 35 -
12 3.5 Station Efficiency Evaluation Both overall station efficiency (wall to RF) was evaluated in the range 0 to 400kW as well as the anode efficiency of both running tetrodes. The voltages and currents delivered to the station through the threephase mains were measured using FREIA facilities built in monitors for the used three phase lines. Only a minor amount of measurement equipment was connected on the same three phase lines making the read values correspond well to the power consumption of the overall station. Station P. Out [kw] Voltage L Voltage L Voltage L Current L , , ,5 Current L ,5 73 Current L ,5 72,2 Power Avg [kw] 10, , ,8 45 Figure 11. Total station efficiency calculated from mains line to RF out / 35 -
13 The efficiency of both tetrodes was calculated using the measured values of anode voltage and current consumption in relation to the RF power generated in the corresponding tetrode. Figure 12. Calculated HPA1 tetrode anode efficiency. Figure 13. Calculated HPA2 tetrode anode efficiency / 35 -
14 3.6 Crowbar Test Test of crowbar by crowbar test buttons. No remarks. 3.7 Series Switch Installation & Test When the station was delivered to FREIA, Uppsala one of the series switches was missing due to being damaged before shipping. A replacement switch had been ordered from Astrol and was installed in time for the on-site test. During initial installation it was discovered that the switch response to the trigger wire (clearly seen in red in Fig. 14) was inverted in relationship to the previous switches. Astrol was contacted and admitted to the replacement switch having been manufactured in this way and the response also told that Astrol would be more stringent in future manufacturing to make sure each switch is manufactured identically. Due to this effect the series switches installed in the station uses mirrored connection of the trigger line, as is seen in Fig. 14. Figure 14. Installed anode power supply series switches from Astrol. Red cables are trigger signal / 35 -
15 The series switch used in the station was tested as follows Test set up: R1 4.7 R2 4.7 R3 4.7 R4 4.7 L1 10uH R5 4.7 R6 4.7 Series switch U2 L3 220uH Dbreak D1 Pulse current transformer F2 Crowbar test C1 54uF C2 54uF F1 C3 54uF di/dt current transformer 2 Crowbar U1 0 1 Wiretester 2 F GAIN = 1 LEM Current sensor F3 F GAIN = 1 R8 dv/dt detector 0 F GAIN = 1 0 U3 0 1 R9 0 0 Figure 15. Schematic of series switch test setup. The performance of both series switches and crowbar was evaluated using a short circuit wire tester. The setup used can be seen in Fig. 16 and Fig. 17. The station successfully passed the short circuit wire test with the anode power supply voltage set to 18 kv. Figure 16. Short circuit wire tester connected to station anode high voltage power supply / 35 -
16 Figure 17. Short circuit wire tester setup connected and boxed off to provide security / 35 -
17 3.8 Tube Installation After verification of all non-rf operation of the station (including power-supplies idle voltages, control logic and water flow) both HPA1 and HPA2 were fitted with Thales TH-595 tubes. Both tubes were installed and checked to verify that the seals for the liquid anode cooling were leak free. Figure 18. Tetrode cavity with anode coolant lines (red) disconnected in preparation for tube insertion / 35 -
18 3.9 Modulator In order to run the station in pulsed mode a blanking pulse synchronized to the input RF pulse was required as well. Also, the rise time of the input RF pulse should be limited to approximately 20 us in order to make sure no overshoot appears on the output pulse. Both these parameters were included by the use of a custom modulator loaned to FREIA by Itelco-Electrosys. The modulator used was only intended for station testing as custom modulator system will be used at FREIA during normal operation but was not yet fully realized at the time of the on-site acceptance test. Figure 19. Blanking pulse generator and RF modulator provided by Itelco-Electrosys Interlock Settings The following settings were used for the interlocks a. Anode power limit 800 kw b. Peak anode power average rms 40 kw. c. Screen grid power max 400 W. d. Anode peak current 30 A. e. Screen grid peak current 800 ma. f. Anode overvoltage 18 kv. g. Anode minimum voltage 10 kv. h. Control grid voltage window V i. Control grid peak current 4 A.(Sink) j. Control grid max source current 0.5 A / 35 -
19 4. RF Characteristics The RF characteristics of the station were evaluated for the complete total power range of 40 kw to 400 kw. Measured parameters were primarily measured using a Rigol DS4045 Oscilloscope and a Rigol DSA815 spectrum analyzer. The measured results are presented below. 4.1 Power Measurement Setup When measuring the performance of the RF station the built in directional couplers were used. The corresponding coupling values of all built in directional couplers is listed below. Directional Couplers Value [db] Value [db] Driver A Output [dbm] Driver B Output [dbm] Forward -57,6 Forward -57,6 Reverse -47,6 Reverse -46,6 Value [db] Value [db] Tetrode A Output [dbm] Tetrode B Output [dbm] Forward -70,6 Forward -70,6 Reverse -60,6 Reverse -60,6 Value [db] Value [db] Station Out [dbm] Dummy Load [dbm] Forward -74,2 Forward -73,3 Reverse -64,2 Reverse -63,3 When measuring the output pulse using the built in directional couplers the insertion loss of the cable used to connect between the couplers and the measurement equipment was characterized using a Keysight FieldFox network analyzer and is given below. Cable Losses Spectrum Analyzer Cable S21-1,2 db - 18 / 35 -
20 Fig. 20 shows measured transmission coefficient of the low-pass filters mounted on the station. At MHz the insertion loss was 0.2 db and was used to calibrate the power meter used to measure the absolute power output of the station. Figure 20. S 21 measurements on low-pass filters provided with station. Fig. 21 shows the relationship between set values used to obtain a specific power level and the actual power level measured. The plotted difference between designated and measured values are <0.2dB and is considered to be below the total combined measurement accuracy of absolute power measurements with the equipment used. Figure 21. Relationship between designated power and measured power / 35 -
21 4.2 Cavity Tuning Measurements After mounting the tubes the cavity output was tuned at low power levels using a Keysight FieldFox network analyzer. Fig. 22 shows the measured transfer function of HPA1 before tuning and Fig. 23 shows the transfer function after tuning. The measured bandwidth after tuning was 11.4 MHz. The same procedure was carried out for HPA2 and the -3 db bandwidth measured to 12 MHz. Figure 22. S 21 measurements on installed tetrode HPA1 at low power before tuning. Figure 23. S 21 measurements on installed tetrode HPA1 at low power after tuning / 35 -
22 4.3 Gain & Linearity Measurements The gain and linearity of both the complete station as well as that of tetrodes and drivers were measured and evaluated for the total output power range of 40 kw to 400 kw and is presented below. Combined Station Station P. Out [kw] Power - In [dbm] -6,8-4,8-3,62-2,65-2,02-1,22-0,67-0,08 0,48 1,29 Power - FWD [dbm] 0,3 3,48 5,07 6,37 7,15 8,22 8,92 9,57 10,06 10,47 Power - Out [dbm] 75,7 78,88 80,47 81,77 82,55 83,62 84,32 84,97 85,46 85,87 Gain [db] 82,5 83,68 84,09 84,42 84,57 84,84 84,99 85,05 84,98 84,58 Figure 24. Total measured gain of station for all output power levels. Driver Section A Station P. Out [kw] Power - In [dbm] -9,8-7,8-6,62-5,65-5,02-4,22-3,67-3,08-2,52-1,71 Power - FWD [dbm] 0,37 2,5 3,78 4,75 5,41 6,3 6,89 7,48 8,08 8,95 Power - Out [dbm] 59,17 61,3 62,58 63,55 64,21 65,1 65,69 66,28 66,88 67,75 Gain [db] 68,97 69,1 69,2 69,2 69,23 69,32 69,36 69,36 69,4 69,46-21 / 35 -
23 Figure 25. Measured gain of driver HPA1 for all power levels. Driver Section B Station P. Out [kw] Power - In [dbm] -9,8-7,8-6,62-5,65-5,02-4,22-3,67-3,08-2,52-1,71 Power - FWD [dbm] 1,38 3,35 4,49 5,53 6,16 7,02 7,58 8,18 8,72 9,6 Power - Out [dbm] 60,18 62,15 63,29 64,33 64,96 65,82 66,38 66,98 67,52 68,4 Gain [db] 69,98 69,95 69,91 69,98 69,98 70,04 70,05 70,06 70,04 70,11 Figure 26. Measured gain of driver HPA2 for all power levels / 35 -
24 Amp Section A Station P. Out [kw] Power - In [dbm] -9,8-7,8-6,62-5,65-5,02-4,22-3,67-3,08-2,52-1,71 Power - FWD [dbm] 1 4,2 5,84 7,02 7,83 8,82 9,51 10,12 10,65 11,08 Power - Out [dbm] 72,8 83,8 77,64 78,82 79,63 80,62 81,31 81,92 82,45 82,88 Gain [db] 82,6 91,6 84,26 84,47 84,65 84,84 84, ,97 84,59 Figure 27. Measured gain of HPA1 for all power levels. Figure 28. Measured gain of tetrode HPA1 for all power levels / 35 -
25 Amp Section B Station P. Out [kw] Power - In [dbm] -9,8-7,8-6,62-5,65-5,02-4,22-3,67-3,08-2,52-1,71 Power - FWD [dbm] 0,75 3,82 5,4 6,81 7,56 8,71 9,41 10,07 10,55 10,95 Power - Out [dbm] 72,55 75,62 77,2 78,61 79,36 80,51 81,21 81,87 82,35 82,75 Gain [db] 82,35 83,42 83,82 84,26 84,38 84,73 84,88 84,95 84,87 84,46 Figure 29. Measured gain of HPA2 for all power levels. Figure 30. Measured gain of tetrode HPA2 for all power levels / 35 -
26 4.4 Droop Measurements Droop measurements of the output pulse were performed at 400 kw output power. A total combined output RF power droop of 0.3 db was recorded and is presented in Fig. 31 through 35. In measurements of both the combined output pulse as well as the individual tetrode outputs an amplitude distortion can be seen in the first half of the pulse corresponding in time to the measured response time of the screen grid power supply. Figure 31. Measured amplitude and droop of combined output pulse for full pulse at 400 kw. Figure 32. Measured amplitude and droop of HPA2 output pulse for full pulse at 400 kw / 35 -
27 Figure 33. Measured amplitude and droop of HPA1 output pulse for full pulse at 400 kw. Figure 34. Measured amplitude and droop of HPA1 driver output pulse for full pulse at 400 kw / 35 -
28 Figure 35. Measured amplitude and droop of power delivered to load for full pulse at 400 kw / 35 -
29 4.5 Bandwidth at 400 kw The station bandwidth at 400 kw output power was measured by using a Rigol DSA815 spectrum analyzer with a 10 MHz span set to maximum hold. The input frequency was varied in the range of +/- 2.5 MHz and the output power recorded. The resulting output power measured on the built in directional coupler can be seen in Fig. 36. As can be seen the station exhibited minimal gain variation in the set frequency range. Any variations shown is attributed to the fact that the measurement required a frequency sweep with maximum hold and some variation due to synchronization issues of the swept points to the input RF pulses. In the figure 10.5 dbm corresponds to an output power of 400 kw. Figure 36. Bandwidth measurements of combined station output at 400 kw for +/- 2.5 MHz range 4.6 Harmonics Harmonics were measured at 400 kw and are listed below in conjunction with the output power measured at MHz Frequency [MHz] 352,2 704, Output [dbm] 85,86 35,1 33,2 4.7 Spurious Using the Rigol DSA815 spectrum analyzer with the maximum frequency span of 1.5 GHz no spurious signals in excess if the tender specified -60 dbc was recorded / 35 -
30 4.8 Phase Stability The phase stability of the output pulse was measured by sampling the complete output pulse using a Rigol DS4054 Oscilloscope using a sample-rate of 2 GSa/s. The recorded.wfm traces were imported in Matlab and the phase calculated using a FFT of the recorded traces. The measured results are presented below. Figure 37. Phase-shift between station input and station output relative to initial value at 400 kw. Figure 38. Phase-shift between station input and HPA1 tetrode output relative to initial value at 400 kw / 35 -
31 Figure 39. Phase-shift between station input and HPA1 driver output relative to initial value at 400 kw. Figure 40. Phase-shift between station input and station output relative to initial value at 200 kw / 35 -
32 Figure 41 Phase-shift between station input and HPA1 tetrode output relative to initial value at 200 kw. Figure 42. Phase-shift between station input and HPA1 driver output relative to initial value at 200 kw / 35 -
33 5. Epics Interface The remote control from Epics has been tested during the last day (Friday). The first three days have been used by Stefano Dilio to test the bug fixes and additions made in the new firmware. The test has been done on the spare Central Control Unit (CCU) not connected to the power station. The new features added to the firmware as compared to the firmware that came installed in the CCU in the power station: 1. Added status bit for Automatic Gain Control 2. Added remote command to reset IP communication buffers 3. Added possibility (only from local control panel) to specify the period for automatic reset of IP communication buffers. Setting the period to 0 disables the automatic resets. The improvements and bug fixes done during the acceptance tests: 1. Fixed some pointer reference error (the SNMP object pointed to the wrong hardware) 2. Fixed SNMP Agent status indication 3. Improved the response time for the Epics commands by tuning some parameters for interprocessor communication over RS-232 line in the CCU. During the tests all acquisition values and status bits have been compared with the local display and no discrepancies have been found. The observed update rate for all parameters is about one second and is limited by the Power station s internal communication architecture. This update rate is often delayed by a few seconds after sending the commands/settings to the station. All commands and settings have been tested and worked properly. However, there are some limitations on sending the remote commands and settings. The most serious is that it does not work to send the setting for two or more parameters at the same time. Only value for one parameter is accepted and there is no feedback (other than by checking the read-back value) that the rest is silently ignored. The second limitation is that the commands/settings can t be accepted more often than every few seconds (recommended by Itelco-Electrosys delay is 5 s). These limitations don t cause serious problems during a normal operation of the station at FREIA but might be unacceptable at ESS / 35 -
34 6. 0Open Issues & Remarks During the acceptance test of the station a few issues and remarks were noted which related to either the Epics interface of the station or to the electrical/physical performance of the station. Any remarks or issues are listed below with the corresponding proposed cause of action. Itelco-Electrosys has shown a positive attitude towards working on these long-term improvements. The Epics improvements can be done just by updating the firmware without any need for changing the hardware. Uploading of the new firmware to the CCU can be easily done by FREIA staff. All issues listed below are considered minor issues and does not negatively affect the overall operation of the station at FREIA Description Type Scope Part Action Replacement switch provided by Astrol had inverted trigger cable connection compared to previous switch Remark Long Term UU/IE Astrol has noted the issue and future manufactured switches will be properly standardized Response time of screen grid power supplies are a bit long causing slight distortion of output pulse amplitude and phase Issue Long Term UU Investigate if current supply could be improved or find a suitable replacement Linearity of the power station is slightly of out the tender specification due to variation in gain for lower output power levels (<100 kw combined output) Remark Long Term UU Find exact limitations of tetrodes (linearity vs efficiency tradeoff) and determine feasibility of current specifications Some variation of control grid bias settings between HPA1 and HPA2 Anode efficiency of HPA2 slightly below specified requirements (<65%) at full power, currently reaching roughly 60% Risetime of RF input pulse needs to be externally limited to be no less than 20 μs Issue Long Term UU Remark Long Term UU Remark Long Term UU No status bit for "Crowbar Fired" Issue Short Term UU MIB file documentation/comments should be updated Remark Short Term UU Switch tubes between HPA1 and HPA2 to determine if tube related, if not further investigation might be required Determine cause of anode efficiency difference and propose solution Investigate if overshoot due to fast risetimes can be reduced Add a status bit for Crowbar Fired (new firmware) Update the MIB file (only the documentation/comments part) - 33 / 35 -
35 HPA.1 and HPA.2 PIB Water Conductivity Alarm and Warning mask timer settings MIB capacitor Charge Power not reliably measured Description of dependencies/permissives for all commands and settings not available Delays in communication when sending commands/settings to the station Cannot process all incoming commands/settings in one burst Issue Short Term UU Issue Short Term UU Remark Short Term UU Issue Long Term UU/IE Issue Long Term UU/IE Increase HPA.1 and HPA.2 PIB Water Conductivity Alarm and Warning mask timer when the system is powered (from 20 to 36 secs) Delete from MIB capacitor Charge Power Documentation updated already done Improve the inter-processor communication in the CCU Add a FIFO buffer for incoming commands/settings - 34 / 35 -
36 7. 0Conclusions The 400 kw RF station delivered by Itelco-Electrosys to FREIA, performed well during on-site acceptance tests. A few smaller remarks have been made as pointed out in Section. The station fulfills all major tender specifications apart from a few minor deviations as noted in Section 6. Following the on-site acceptance test initial further investigations will focus on the performance of the screen-grid supplies as well as further characterization of the station. Some unbalance in bias conditions between HPA1 and HPA2 TH-595 bias voltages were recorded and test including a switch between the tubes mounted in HPA1 and HPA2 has been proposed to verify that the difference in bias conditions stems from difference in tube characteristics and not from the power supplies, power meters and control logic in the respective stations. The station will also be interfaced with the proper modulator system in development in FREIA and the temporary modulator provided by Itelco-Electrosys will be shipped back to their facilities. Further work will also be performed in improving the EPICS interface, including trying to reduce the delay times in the CCU. Overall the station has been considered to pass the on-site acceptance test and start operations within FREIA / 35 -
DB Science 400 kw RF Station Site Acceptance Test
Report 2017/01 January 2017 DEPARTMENT OF PHYSICS AND ASTRONOMY UPPSALA UNIVERSITY DB Science 400 kw RF Station Site Acceptance Test M. Jobs, R. Wedberg, K. Gajewski, Uppsala, Sweden Department of Physics
More informationMHz 58 db 1 KW RF Amplifier (EDA 00097)
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN A&B DEPARTMENT AB-Note-2004-029 RF 0.2-10 58 1 KW RF Amplifier (EDA 00097) M. Paoluzzi 25 th March 2004 Geneva, Switzerland 1 1. DESCRIPTION 1.1. GENERAL
More informationSensitivity of Series Direction Finders
Sensitivity of Series 6000-6100 Direction Finders 1.0 Introduction A Technical Application Note from Doppler Systems April 8, 2003 This application note discusses the sensitivity of the 6000/6100 series
More informationKeysight Technologies PNA-X Series Microwave Network Analyzers
Keysight Technologies PNA-X Series Microwave Network Analyzers Active-Device Characterization in Pulsed Operation Using the PNA-X Application Note Introduction Vector network analyzers (VNA) are the common
More informationDSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.
FAQ Instrument Solution FAQ Solution Title DSA-815 Demo Guide Date:08.29.2012 Solution: The DSA 800 series of spectrum analyzers are packed with features. Spectrum analyzers are similar to oscilloscopes..
More informationAgilent 8902A Measuring Receiver
Agilent 8902A Measuring Receiver Technical Specifications Agilent 11722A Sensor Module Agilent 11792A Sensor Module Agilent 11793A Microwave Converter Agilent 11812A Verification Kit The Agilent Technologies
More informationUnderstanding RF and Microwave Analysis Basics
Understanding RF and Microwave Analysis Basics Kimberly Cassacia Product Line Brand Manager Keysight Technologies Agenda µw Analysis Basics Page 2 RF Signal Analyzer Overview & Basic Settings Overview
More informationFREIA Facility for Research Instrumentation and Accelerator Development Infrastructure and Control Architecture
FREIA Facility for Research Instrumentation and Accelerator Development Infrastructure and Control Architecture Konrad Gajewski 10 September 2013, Uppsala Why FREIA? Several circumstances test stand for
More informationKeysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
More informationFM TRANSMITTERS TESTS
FM TRANSMITTERS TESTS - FACTORY TESTS - SITE TESTS Page 1 of 11 I. FACTORY TEST (on dummy load) TX s.n... Exciter no...(s.n...) Date... Page 2 of 11 1.PERFORMANCE A) OPERATING FREQUENCY Carrier stability:
More informationRIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.
RIGOL Data Sheet DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A Product Overview DG3000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationExternal Source Control
External Source Control X-Series Signal Analyzers Option ESC DEMO GUIDE Introduction External source control for X-Series signal analyzers (Option ESC) allows the Keysight PXA, MXA, EXA, and CXA to control
More informationAgilent ESA-L Series Spectrum Analyzers
Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are
More informationAgilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software
Test System Overview Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview The Agilent Technologies test system is designed to verify the performance of the
More information2100L Broadband Power Amplifier
2100L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationSignal Generators for Anritsu RF and Microwave Handheld Instruments
Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis
More informationAnalog Arts SF900 SF650 SF610 Product Specifications
www.analogarts.com Analog Arts SF900 SF650 SF610 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without prior
More informationA 500 Broadband Power Amplifier
A 500 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More information1140LA Broadband Power Amplifier
1140LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationKeywords: GPS, receiver, GPS receiver, MAX2769, 2769, 1575MHz, Integrated GPS Receiver, Global Positioning System
Maxim > Design Support > Technical Documents > User Guides > APP 3910 Keywords: GPS, receiver, GPS receiver, MAX2769, 2769, 1575MHz, Integrated GPS Receiver, Global Positioning System USER GUIDE 3910 User's
More informationPXA Configuration. Frequency range
Keysight Technologies Making Wideband Measurements Using the Keysight PXA Signal Analyzer as a Down Converter with Infiniium Oscilloscopes and 89600 VSA Software Application Note Introduction Many applications
More informationAgilent N9320B RF Spectrum Analyzer
Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned
More informationSpecification for Radiated susceptibility Test
1 of 11 General Information on Radiated susceptibility test Supported frequency Range : 20MHz to 6GHz Supported Field strength : 30V/m at 3 meter distance 100V/m at 1 meter distance 2 of 11 Signal generator
More information3100LA Broadband Power Amplifier
3100LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationLOI progress report INTRODUCTION
LOI-5 LOI progress report Summary of Experiments from August 4th through 22nd, 2008 November 10, 2008 INTRODUCTION Waveform distortions of the LOI system were investigated using a liquid resistor in place
More informationRIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.
RIGOL Data Sheet DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A Product Overview DG2000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables to generate
More informationPXIe Contents SPECIFICATIONS. 14 GHz and 26.5 GHz Vector Signal Analyzer
SPECIFICATIONS PXIe-5668 14 GHz and 26.5 GHz Vector Signal Analyzer These specifications apply to the PXIe-5668 (14 GHz) Vector Signal Analyzer and the PXIe-5668 (26.5 GHz) Vector Signal Analyzer with
More informationModels FSW-0010 FSW-0020
MICROWAVE FREQUENCY SYNTHESIZERS Features: 0.1 to 10 GHz and 0.2 to 20 GHz Coverage 0.001 Hz Resolution Power Calibration and Control 100 μs Frequency Switching Instrument-Grade Spectral Purity QuickSyn
More informationPXIe Contents. Required Software CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5160 This document contains the verification and adjustment procedures for the PXIe-5160. Refer to ni.com/calibration for more information about calibration solutions. Contents
More informationContents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer
CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5668R (NI 5668R) vector signal analyzer (VSA)
More informationMeasurement of Digital Transmission Systems Operating under Section March 23, 2005
Measurement of Digital Transmission Systems Operating under Section 15.247 March 23, 2005 Section 15.403(f) Digital Modulation Digital modulation is required for Digital Transmission Systems (DTS). Digital
More informationAnalog Arts SG985 SG884 SG834 SG814 Product Specifications [1]
www.analogarts.com Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, and an arbitrary
More informationGA GHz. Digital Spectrum Analyzer
Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com
More informationLOI Progress Report -- Summary of Experiment in January
LOI Progress Report -- Summary of Experiment in January 2010 -- LOI-7 February 18, 2010 1. Introduction Following the previous experiments in October, 2009, a new method to improve the RF waveform distortions
More informationChapter 5 Specifications
RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.
More informationAPPH6040B / APPH20G-B Specification V2.0
APPH6040B / APPH20G-B Specification V2.0 (July 2014, Serial XXX-XX33XXXXX-XXXX or higher) A fully integrated high-performance cross-correlation signal source analyzer for to 7 or 26 GHz 1 Introduction
More informationDSA700 Series Spectrum Analyzer
DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.
More informationOPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING
1 Introduction Radiated emission tests are typically carried out in anechoic chambers, using antennas to pick up the radiated signals. Due to bandwidth limitations, several antennas are required to cover
More informationEXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947
EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 7.1 RF Power -- Pursuant to 47 CFR 2.947(c) Method of Conducted Output Power Measurement: Adaptation of TIA/EIA-603-A clause 2.2.1 for Pulsed Measurements
More informationMEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR
MEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR The SCTE defines hum modulation as, The amplitude distortion of a signal caused by the modulation of the signal by components of the power
More informationRIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design
RIGOL Data Sheet DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Product Overview DG1000 series Dual-Channel Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationMSE M A G N E T I C S O U N D E N H A C E R. Passion
Passion for F M &T V Broadcasting MOZART Series Green RF tecnology High Efficiency 120W to 5000W Compact and Modular FM Transmitters Tr MSE M A G N E T I C S O U N D E N H A C E R TECHNICAL CHARACTERISTICS
More informationSC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.
SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter Datasheet 2017 SignalCore, Inc. support@signalcore.com P RODUCT S PECIFICATIONS Definition of Terms The following terms are used throughout this datasheet
More informationAnalog Arts SF990 SF880 SF830 Product Specifications
1 www.analogarts.com Analog Arts SF990 SF880 SF830 Product Specifications Analog Arts reserves the right to change, modify, add or delete portions of any one of its specifications at any time, without
More informationModel 855 RF / Microwave Signal Generator
Features Very low phase noise Fast switching Phase coherent switching option 2 to 8 phase coherent outputs USB, LAN, GPIB interfaces Applications Radar simulation Quantum computing High volume automated
More informationTechnical Service Bulletin DCX AGC Setup Procedure for MODAP Exciters
Technical Service Bulletin 030624 DCX AGC Setup Procedure for MODAP Exciters This service bulletin provides the procedure to properly install and align the total system automatic gain control (AGC) upgrade
More informationWILCOX 914A RF modules kb
Local Oscillator 0 50 0. MHz uf A T V dc / A Power Supply R0 R0 0 0 k n 0 00uH V 00 L0 0 +.V k N 0 0-0mV +0 V x N 55V 0 0 k 50mA MHz n 5 50 5k C 5 0 ON/OFF 0 MC IF AMPLIFIER n RFC p C0 W N05 STC50 5-0
More informationR3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation
R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World
More informationKeysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set
Keysight Technologies E5071C ENA Vector Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set
More informationCharacterisation of the VELO High Voltage System
Characterisation of the VELO High Voltage System Public Note Reference: LHCb-2008-009 Created on: July 18, 2008 Prepared by: Barinjaka Rakotomiaramanana a, Chris Parkes a, Lars Eklund a *Corresponding
More informationAnalog Arts SL987 SL957 SL937 SL917 Product Specifications [1]
www.analogarts.com Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1] 1. These models include: an oscilloscope, a spectrum analyzer, a data recorder, a frequency & phase meter, an arbitrary
More informationHP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!
HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web! On-line curator: Glenn Robb This document is for FREE distribution only!
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR 304/1 DATA SHEET Frequency range: 300 khz to 3.2 GHz Measured parameters: S11, S21, S12, S22 Dynamic range of transmission measurement magnitude: 135 db Measurement time
More informationKeysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note
Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators Application Note 02 Keysight 8 Hints for Making Better Measurements Using RF Signal Generators - Application Note
More informationThe VSX3622, a 1.5 kw X-Band GaN Power Amplifier for Radar Application
The VSX3622, a 1.5 kw X-Band GaN Power Amplifier for Radar Application George Solomon, Dave Riffelmacher, Matt Boucher, Mike Tracy, Brian Carlson, Todd Treado Communications & Power Industries LLC, Beverly
More informationELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS
Academic Year 2015-2016 ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS V. BEAUVOIS P. BEERTEN C. GEUZAINE 1 CONTENTS: EMC laboratory session 1: EMC tests of a commercial Christmas LED light
More informationBroadcasting MSE M A G N E T I C S O U N D E N H A C E R. Passion
Passion for F M &TV Broadcasting MOZART Series Green RF tecnology High Efficiency 300W to 5000W Compact and Modular FM Transmitters Tr MSE M A G N E T I C S O U N D E N H A C E R TECHNICAL CHARACTERISTICS
More informationPXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth
IBRATION PROCEDURE PXIe-5646 Reconfigurable 6 GHz Vector Signal Transceiver with 200 MHz Bandwidth This document contains the verification and adjustment procedures for the PXIe-5646 vector signal transceiver.
More informationData Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved
Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...
More informationAirScope Spectrum Analyzer User s Manual
AirScope Spectrum Analyzer Manual Revision 1.0 October 2017 ESTeem Industrial Wireless Solutions Author: Date: Name: Eric P. Marske Title: Product Manager Approved by: Date: Name: Michael Eller Title:
More informationTechnical Service Bulletin DCX AGC Setup Procedure for ADAPT IV Exciters
Technical Service Bulletin 110427 DCX AGC Setup Procedure for ADAPT IV Exciters This service bulletin provides the procedure to properly install and align the total system automatic gain control (AGC)
More informationCompact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES
Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Frequency range: 9 khz - 6.5 or 8.5 GHz Measured parameters: S11, S12, S21, S22 Wide output power adjustment range: -50 dbm to +5 dbm
More informationOPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING
1 Introduction Radiated emission tests are typically carried out in anechoic chambers, using antennas to pick up the radiated signals. Due to bandwidth limitations, several antennas are required to cover
More informationModel 310H Fast 800V Pulse Generator
KEY FEATURES Temperature Stability +/-5ppm 100 V to 800 V into 50 Ω
More informationContents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer
CALIBRATION PROCEDURE NI PXIe-5665 3.6 GHz and 14 GHz RF Vector Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5665 (NI 5665) RF vector signal analyzer
More informationAgilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs
Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs Application Note Fast, accurate synthesizer switching and settling are key performance requirements in
More informationAgilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet
Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet 10 MHz to 110 GHz Specifications apply after full user calibration, and in coupled attenuator
More informationModel 7000 Series Phase Noise Test System
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Model 7000 Series Phase Noise Test System Fully Integrated System Cross-Correlation Signal Analysis to 26.5 GHz Additive
More information2026Q CDMA/GSM Interferer MultiSource Generator
Signal Sources 2026Q CDMA/GSM Interferer MultiSource Generator The 2026Q is designed to work with a radio test set to provide a fully integrated radio receiver test solution for cellular and PCS systems
More informationA NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER
GENERAL A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER by Charles H. Currie Scientific-Atlanta, Inc. 3845 Pleasantdale Road Atlanta, Georgia 30340 A new generation programmable, phase-amplitude
More informationNotes on DYNALYZER HVU Usage
December 19, 1986 Notes on DYNALYZER HVU Usage It has been shown that the Dynalyzer HVU gives accurate reproduction of tube waveforms for almost all applications. Possible cautions, a) kv frequency response
More informationPulsed S-Parameter Measurements using the ZVA network Analyzer
Pulsed S-Parameter Measurements using the ZVA network Analyzer 1 Pulse Profile measurements ZVA Advanced Network Analyser 3 Motivation for Pulsed Measurements Typical Applications Avoid destruction of
More informationIdeal for high dynamic range measurements from compression to noise floor
USB/Ethernet Very Wideband Synthesized Signal Generator 5Ω -75 dbm to +14 dbm, 25 khz - 64 MHz The Big Deal Cost effective production test solution Power level resolution of.1 db Frequency resolution under.1
More informationMQH0XX-YYDS3-ZZZ-2S. High Power 2 Channel RF Driver: For 2 Acousto-optic Q-Switches. Description: Key Features: Applications:
High Power 2 Channel RF Driver: For 2 Acousto-optic Q-Switches MQH0XX-YYDS3-ZZZ-2S Former Model Number: 390XX-YYDSZZZ-2CH-A Description: The MQH0XX-YYDS3-ZZZ-2S is a High Power RF Driver with two RF outputs
More informationCost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK
Cost-Effective Traceability for Oscilloscope Calibration Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK Abstract The widespread adoption of ISO 9000 has brought an increased
More informationCharacterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes
Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes Application Note 1493 Table of Contents Introduction........................
More informationAdvances in Antenna Measurement Instrumentation and Systems
Advances in Antenna Measurement Instrumentation and Systems Steven R. Nichols, Roger Dygert, David Wayne MI Technologies Suwanee, Georgia, USA Abstract Since the early days of antenna pattern recorders,
More informationQuickSyn Frequency Synthesizers
QuickSyn Frequency Synthesizers The QuickSyn Advantage Our popular line of QuickSyn frequency synthesizers delivers instrumentgrade performance up to 82 GHz, increased functionality, and efficient power
More informationDSA800. No.1 RIGOL TECHNOLOGIES, INC.
No.1 DSA800 9 khz to 1.5 GHz Frequency Range Typical -135 dbm Displayed Average Noise Level (DANL) -80 dbc/hz @10 khz offset Phase Noise Total Amplitude Uncertainty
More informationSignal Forge 1800M Frequency Expansion Module. 1.0 GHz to 1.8 GHz. User Manual
TM TM Signal Forge 1800M Frequency Expansion Module 1.0 GHz to 1.8 GHz User Manual Technical Support Email: Support@signalforge.com Phone: 512.275.3733 x2 Contact Information Web: www.signalforge.com
More informationSpectrum Analyzers 2680 Series Features & benefits
Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level
More informationSC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.
SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter Datasheet Rev 1.2 2017 SignalCore, Inc. support@signalcore.com P R O D U C T S P E C I F I C A T I O N S Definition of Terms The following terms are used
More information2520 Pulsed Laser Diode Test System
Complete pulse test of laser diode bars and chips with dual photocurrent measurement channels 0 Pulsed Laser Diode Test System Simplifies laser diode L-I-V testing prior to packaging or active temperature
More informationA COMPACT, AGILE, LOW-PHASE-NOISE FREQUENCY SOURCE WITH AM, FM AND PULSE MODULATION CAPABILITIES
A COMPACT, AGILE, LOW-PHASE-NOISE FREQUENCY SOURCE WITH AM, FM AND PULSE MODULATION CAPABILITIES Alexander Chenakin Phase Matrix, Inc. 109 Bonaventura Drive San Jose, CA 95134, USA achenakin@phasematrix.com
More informationThis report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87.
FCC test report for the ADR-7050 Radio This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87. Prior to this FCC approval
More informationContinental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter
Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter Includes the 802A solid -state exciter LED status indicators Features SCR Power Control Automatic RF Power Output Control Automatic SWR Circuit
More informationSeries 48 Water Cooled Laser & UC-2000 Quick Start Guide
Important Read all Danger, Warning, Caution terms, symbols, and instructions located in the (Laser Safety Hazard information) sections in the Series 48 Laser Operation Manuals. http://www.synrad.com/synrad/docroot/resources/libraries/manuals
More informationFREQUENCY SYNTHESIZERS, SIGNAL GENERATORS
SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And
More informationQ: What does it mean if the RF generator will not put out full power and the reflected power is nearly equal to forward power?
Q: What does it mean if the RF generator will not put out full power and the reflected power is nearly equal to forward power? A: This generally means that the generator is in "reflected foldback." The
More informationFFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS. Version 1.0 MICRON OPTICS, INC.
FFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS Version 1.0 MICRON OPTICS, INC. 1852 Century Place NE Atlanta, GA 30345 USA Tel (404) 325-0005 Fax (404) 325-4082 www.micronoptics.com Page 2 Table
More informationAgilent 86030A 50 GHz Lightwave Component Analyzer Product Overview
Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview 2 Characterize 40 Gb/s optical components Modern lightwave transmission systems require accurate and repeatable characterization of their
More informationDG5000 series Waveform Generators
DG5000 series Waveform Generators DG5000 is a multifunctional generator that combines many functions in one, including Function Generator, Arbitrary Waveform Generator, IQ Baseband /IQ IF, Frequency Hopping
More informationCS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL
CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive
More informationAgilent N9343C Handheld Spectrum Analyzer (HSA)
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Agilent N9343C Handheld Spectrum Analyzer (HSA) 1 MHz to 13.6 GHz (tunable to 9 khz) Data Sheet Field
More informationKeysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers
Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers White Paper Abstract This paper presents advances in the instrumentation techniques that can be used for the measurement and
More informationAgilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)
Agilent E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 0 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5091A Multiport Test Set E5092A Configurable Multiport Test
More informationHP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One
HP 8901B Modulation Analyzer 150 khz - 1300 MHz HP 11722A Sensor Module 100 khz - 2600 MHz Technical Specifications Four Instruments In One RF Power: ±0.02 db instrumentation accuracy RF Frequency: 10
More informationArbitrary/Function Waveform Generators 4075B Series
Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators
More informationLab Assignment 1 Spectrum Analyzers
1 Objectives THE UNIVERSITY OF BRITISH COLUMBIA Department of Electrical and Computer Engineering ELEC 391 Electrical Engineering Design Studio II Lab Assignment 1 Spectrum Analyzers This lab consists
More informationReconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth
CALIBRATION PROCEDURE PXIe-5840 Reconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth This document contains the verification procedures for the PXIe-5840 vector signal transceiver. Refer
More information