1 Overview. Pressure Measurement Transmitters for gauge pressure for the paper industry. 1/72 Siemens FI US Edition

Size: px
Start display at page:

Download "1 Overview. Pressure Measurement Transmitters for gauge pressure for the paper industry. 1/72 Siemens FI US Edition"

Transcription

1 Siemens AG 207 Overview Benefits High quality and service life High reliability even under etreme chemical and mechanical loads, e.g. abrasion. For aggressive and non-aggressive gases, vapors and liquids Etensive diagnosis and simulation functions Minimum conformity error Small long-term drift Wetted parts made of Hastelloy Infinitely adjustable span from 0.0 bar to bar (0.4 psi to 22 psi) for DS III with HART interface Nominal measuring range from bar to bar (4.5 psi to 22 psi) for DS III with PROFIBUS PA and FOUNDATION Fieldbus interface Infinitely adjustable span from 0.0 bar to bar (0.4 psi to 22 psi) for SITRANS P00 with HART interface Nominal measuring range from bar to bar (4.5 psi to 22 psi) for SITRANS P00 with PROFIBUS PA interface High measuring accuracy Parameterization over control keys and HART Communication, or over PROFIBUS PA or FOUNDATION Fieldbus interface (DS III only). SITRANS P DS III and P00 with PMC connection - Technical description The SITRANS P00 and DS III pressure transmitters have been fitted with special process connections for the paper industry. With the two process connection threads ½" and " flush at the front, the SITRANS P00 and DS III transmitters can be used for all processes in the paper industry. SITRANS P00 and SITRANS PDS III series pressure transmitters are digital pressure transmitters featuring etensive userfriendliness and high accuracy. The parameterization is performed using control keys via HART, PROFIBUS-PA or FOUNDATION Fieldbus interface. Etensive functionality enables the pressure transmitter to be precisely adapted to the plant s requirements. Operation is very simple in spite of the numerous setting options. Transmitters with type of protection "Intrinsic safety" and "Eplosion-proof" may be installed within potentially eplosive atmospheres (zone ) or in zone 0. The transmitters are provided with an EC type eamination certificate and comply with the corresponding harmonized European standards (ATEX). Various versions of the pressure transmitters are available for measuring: Gauge pressure Level Mass level Volume level Application The pressure transmitters of the DS III series, can be used in industrial areas with etreme chemical and mechanical loads. Electromagnetic compatibility in the range 0 khz to GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Eplosion-proof" may be installed within potentially eplosive atmospheres (zone ) or in zone 0. The pressure transmitters are provided with an EC type eamination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be operated locally over control keys or programmed eternally over HART or over PROFIBUS-PA or FOUNDATION Fieldbus interface (only DS III). SITRANS P, DS III series Measured variable: Gauge pressure of aggressive and non-aggressive gases, vapors and liquids. Span (infinitely adjustable) For DS III with HART: bar ( psi) Nominal measuring range For DS III with PROFIBUS PA or FOUNDATION Fieldbus:... bar ( psi) SITRANS P00 Span (infinitely adjustable) For DS III with HART: bar ( psi) Nominal measuring range For DS III with PROFIBUS PA or FOUNDATION Fieldbus:... bar ( psi) /72 Siemens FI US Edition

2 Siemens AG 207 Design SITRANS P DS III SITRANS P DS III and P00 with PMC connection - Technical description Eample for an attached measuring point label Y0 or Y02 = ma. 27 char. Y5 = ma. char. Y99 = ma. 0 char. Y = ma. 27 char.... to... mbar Measuring point number (TAG No.) 24 Measuring point tet 8 2 SITRANS P00 The device comprises: Electronics Housing Measuring cell Plastic cover as access to the input keys 2 Screw cover with viewing pane Digital display 4 Locking screw 5 Process connection Screw cover with viewing pane 7 Rating plate 8 Inlet with cable gland Device front view, SITRANS P DS III The transmitter consists of various components depending on the order. The possible versions are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (7, Figure "Device front view) with the Article No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover is screwed on at the front and rear of the housing. The front cover (2) can be fitted with a viewing pane so that the measured values can be read directly on the display. The inlet (8) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (5). The measuring cell is prevented from rotating by a locking screw (4). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (), which hides the input keys. 5 Digital display 2 Process connection Cable gland 4 Rating plate 5 Screw-on lid 4 Perspective view of the SITRANS P00 The housing has a screw-on lid (5) and, depending on the version, is with or without an inspection window. The electrical terminal housing, the buttons for operation of the device are located under this lid and, depending on the version, the display. The connections for the auiliary power UH and the shield are in the terminal housing. The cable gland is on the side of the housing. The measuring cell with the process connection (2) is located on the bottom of the housing. The measuring cell with the process connection may differ from the one shown in the diagram, depending on the device version. 2 Siemens FI US Edition /7

3 Siemens AG 207 SITRANS P DS III and P00 with PMC connection - Technical description Function Operation of electronics with HART communication 2 Sensor p e 8 M EEPROM Measuring cell 4 μc HART interface Electronics Measuring cell sensor 2 Instrument amplifier Analog-to-digital converter 4 Microcontroller 5 Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 0 Diode circuit and connection for eternal ammeter I A Output current U H Power supply P e Input variable 5 EEPROM Function diagram of electronics The bridge output voltage created by the sensor (, Figure "Function diagram of electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 20 ma. The diode circuit (0) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the input keys (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans bar (94 psi) measure the input pressure compared to atmosphere, the transmitters with spans 0 bar (220 psi) measure compared to vacuum. 0 I A, U H Operation of electronics with PROFIBUS PA communication PA μc interface Sensor p e 8 M EEPROM Measuring cell EEPROM Measuring cell sensor 2 Instrument amplifier Analog-to-digital converter 4 Microcontroller 5 Electrical isolation One non-volatile memory each in the measuring cell and electronics 7 PROFIBUS-PA interface Electronics Power supply 0 Power supply unit Coupler Function diagram of electronics The bridge output voltage created by the sensor (, Figure "Function diagram of electronics") is amplified by the measuring amplifier(2) and digitized in the analog-to-digital converter (). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (). The first memory is linked with the measuring cell, the second with the electronics. This modular design means that the electronics and the measuring cell can be replaced separately from one another. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. PROFIBUS DP Bus- Master 8 Three input keys (local operation) 9 Digital display 0 Power supply DP/PA coupler or link 2 Bus master p e PROFIBUS-PA 2 Input variable /74 Siemens FI US Edition

4 Siemens AG 207 Operation of electronics with FOUNDATION Fieldbus communication SITRANS P DS III and P00 with PMC connection - Technical description Mode of operation of the measuring cell Measuring cell for gauge pressure with front-flush diaphragm 8 M FF μc interface EEPROM Electronics Foundation Fieldbus Power supply 0 Power supply unit Coupler 5 4 p e 2 Measuring cell 2 Process connection Seal diaphragm 4 Filling liquid 5 Silicon pressure sensor Pressure as input variable p e Sensor p e EEPROM Measuring cell Measuring cell sensor 2 Instrument amplifier Analog-to-digital converter 4 Microcontroller 5 Electrical isolation One non-volatile memory each in the measuring cell and electronics 7 FF interface 8 Three input keys (local operation) 9 Digital display 0 Power supply Function diagram of electronics The bridge output voltage created by the sensor (, Figure "Function diagram of electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. p e Input variable Measuring cell for gauge pressure, with front-flush diaphragm for paper industry, function diagram The pressure p e is applied through the process connection (2, Figure "Measuring cell for gauge pressure, with front-flush diaphragm for paper industry, function diagram) to the measuring cell (). This pressure is subsequently transmitted further through the seal diaphragm () and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then fleed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. Parameterization Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input buttons (local operation) With the input buttons you can easily set the most important parameters without any additional equipment. Parameterization using HART Parameterization using HART is performed with a HART Communicator or a PC. SITRANS P transmitter Power supply Communication between a HART Communicator and a pressure transmitter When parameterizing with the HART Communicator, the connection is made directly to the 2-wire cable. SITRANS P transmitter HART communicator HART modem Ω Ω PC or laptop Power supply USB/RS 22 HART communication between a PC communicator and a pressure transmitter Siemens FI US Edition /75

5 Siemens AG 207 SITRANS P DS III and P00 with PMC connection - Technical description When parameterizing with a PC, the connection is made through Parameterization through PROFIBUS PA interface a HART modem. The signals needed for communication in conformity with the HART 5. or. protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameter DS III with HART and P00 with HART Parameters Input keys HART communication Start of scale Full-scale value Electrical damping Start-of-scale value without application of a pressure ("Blind setting") Full-scale value without application of a pressure ("Blind setting") Zero adjustment current transmitter Fault current Disabling of buttons, write protection ) Type of dimension and actual dimension Characteristic (linear) Input of characteristic Freely-programmable LCD Diagnostic functions ) Cancel apart from write protection Diagnostic functions for DS III with HART and P00 with HART Zero correction display Event counter Limit transmitter Saturation alarm Slave pointer Simulation functions Maintenance timer Available physical units of display for DS III with HART and P00 with HART Physical variable Physical dimensions Pressure (setting can also be Pa, MPa, kpa, bar, mbar, torr, atm, made in the factory) psi, g/cm 2, kg/cm 2, inh 2 O, inh 2 O (4 C), mmh 2 O, fth 2 O (20 C), inhg, mmhg Level (height data) m, cm, mm, ft, in Volume m, dm, hl, yd, ft, in, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz Temperature K, C, F, R Miscellaneous %, ma Fully digital communication through PROFIBUS PA, profile.0, is particularly user-friendly. The PROFIBUS connects the DS III PA to a process control system, e.g. SIMATIC PSC 7. Communication is possible even in a potentially eplosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). Parameterization through FOUNDATION Fieldbus interface Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III with FOUNDATION Fieldbus is connected to a process control system. Communication is possible even in a potentially eplosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for DS III with PROFIBUS PA and FOUNDATION Fieldbus, and P00 with PROFIBUS PA and FOUNDATION Fieldbus Adjustable parameters Input keys PROFIBUS PA and FOUNDA- TION Fieldbus interface Electrical damping Zero adjustment (correction of position) Buttons and/or function disabling Source of measured-value display Physical dimension of display Position of decimal point Bus address Adjustment of characteristic Input of characteristic Freely-programmable LCD Diagnostic functions Diagnostic functions for DS III with PROFIBUS PA and FOUNDATION Fieldbus, and P00 with PROFIBUS PA and FOUNDATION Fieldbus Event counter Slave pointer Maintenance timer Simulation functions Display of zero correction Limit transmitter Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be MPa, hpa, kpa, Pa, bar, mbar, torr, made in the factory) atm, psi, g/cm 2, kg/cm 2, mmh 2 O, mmh 2 O (4 C), inh 2 O, inh 2 0 ( 4 C), fth 2 O, mmhg, inhg Level (height data) m, cm, mm, ft, in, yd Mass g, kg, t, lb, Ston, Lton, oz Volume m, dm, hl, yd, ft, in, US gallon, lmp. gallon, bushel, barrel, barrel liquid Temperature K, C, F, R Miscellaneous % /7 Siemens FI US Edition

6 Siemens AG 207 Technical specifications SITRANS P, DS III series for gauge pressure with PMC connection for the paper industry Input Measured variable Gauge pressure Span (fully adjustable) or measuring range, ma. operating pressure and ma. test pressure HART PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring range bar kpa psi bar kpa psi bar kpa psi bar 00 kpa 4.5 psi 4bar 400 kpa 58 psi bar 00 kpa 22 psi SITRANS P DS III with PMC connection Ma. operating pressure MAWP (PS) 4bar 400 kpa 58 psi 7bar 0.7 MPa 02 psi 2 bar 2. MPa 05 psi Ma. perm. test pressure bar 00 kpa 87 psi 0 bar MPa 45 psi 2 bar.2 MPa 44 psi Lower measuring limit 00 mbar a/0 kpa a/.45 psia (For PMC-Style Minibolt no span < 500 mbar adjustable) Upper measuring limit 00% of ma. span Output HART PROFIBUS PA/ FOUNDATION Fieldbus Output signal ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable).55 ma, factory preset to.84 ma - Upper limit (infinitely adjustable) 2 ma, factory preset to 20.5 ma or - optionally set to 22.0 ma Load Without HART communication R B (U H V)/0.02 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART-Communicator) Physical bus - IEC 58-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with ma. supply voltage. Electrical damping (step width 0. s) Set to 2 s ( s) Measuring accuracy Acc. to IEC Reference conditions (All error data refer always refer to the set span) Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Silicone oil filling Room temperature 25 C (77 F) Measuring span ratio r (spread, Turn-Down) r = ma. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic -r % - 5<r 00 (0.005 r ) % Influence of ambient temperature (in percent per 28 C (50 F)) (0.08 r + 0.) % Long-term stability (temperature change ± 0 C (± 54 F)) (0.25 r) % in 5 years Effect of mounting position 0. mbar/0.0 kpa/ psi per 0 inclination (zero point correction is possible with position error compensation) Effect of auiliary power supply % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and 0-5 of nominal measuring range FOUNDATION Fieldbus Siemens FI US Edition /77

7 Siemens AG 207 SITRANS P DS III with PMC connection SITRANS P, DS III series for gauge pressure with PMC connection for the paper industry HART PROFIBUS PA and FOUNDATION Fieldbus Rated conditions Degree of protection to IEC 0529 IP (optional IP/IP8), NEMA 4X Temperature of medium C ( F) Ambient conditions Ambient temperature C ( F) - Transmitter C ( F) Storage temperature C ( F) Climatic class - Condensation Relative humidity % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 2 and NAMUR NE 2 Design Weight (without options).5 kg (. lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi2 or stainless steel precision casting, mat. no Wetted parts materials Gasket (standard) PTFE flat gasket O-ring (minibolt) FPM (Viton) or optionally: FFPM or NBR Measuring cell filling Silicone oil or inert filling liquid Process connection (standard) Flush-mounted, ½", PMC Standard design Process connection (minibolt) Flush-mounted, ", minibolt design Power supply U H Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Power supply - Supplied through bus Separate 24 V power supply - Not necessary Bus voltage Not E V With intrinsically-safe operation V Current consumption Basic current (ma.) ma Start-up current basic current - Yes Ma. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Certificates and approvals Classification according to PED 204/8/EU For gases of fluid group and liquids of fluid group ; complies with requirements of article 4, paragraph (sound engineering practice) /78 Siemens FI US Edition

8 Siemens AG 207. HART communication HART communication Ω Protocol HART Version 5. Software for computer PROFIBUS PA communication Simultaneous communication with master class 2 (ma.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks 2 Analog input - Adaptation to customer-specific process variables SIMATIC PDM 4 Configuration tool or local operation (standard setting address 2) 5 (one measured value) or 0 (two measured values) 0,, or 2 (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version.0, class B Yes, linearly rising or falling characteristic - Electrical damping, adjustable s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks 2 Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container Ma. 0 nodes characteristic with - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root etraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNDATION Fieldbus communication Function blocks SITRANS P DS III with PMC connection function blocks analog input, function block PID Analog input - Adaptation to customer-specific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI US Edition /79

9 Siemens AG 207 SITRANS P DS III with PMC connection Selection and Ordering data Article No. SITRANS P pressure transmitters for gauge pressure, with PMC connection series DS III with HART 7 M F Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cellcleaning Silicone oil normal Inert liquid grease-free to cleanliness level 2 Measuring span (min.... ma.) bar ) ( psi) ) B bar ( psi) C bar ( psi) D Wetted parts materials Seal diaphragm Connection shank Hastelloy Stainless steel B Process connection PMC Style Standard: Thread ½" 2 PMC Style Minibolt: front-flush " (not with minimum span: 500 mbar (7.25 psi) - version "B") Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, 2 setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with compact operating instructions in various EU languages. Eplosion protection None A With ATEX, Type of protection: - "Intrinsic safety (E ia)" B - "Eplosion-proof (E d)" 2) D - E na/ic (Zone 2)" ) E FM + CSA intrinsic safe (is) 4) F With FM + CSA, Type of protection: - "Intrinsic Safe and Eplosion Proof (is + p)" )4) N C Electrical connection / cable entry Female thread M20.5 B Female thread ½-4 NPT C M2 connectors (stainless steel) 5) ) F Display Without display 0 Without visible display (display concealed, setting: ma) With visible display (setting: ma) With customer-specific display (setting as specified, 7 Order code "Y2" required) Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: Quick-start guide Sealing ring ) Only with "PMC Style Standard" process connection 2) Without cable gland, with blanking plug ) Configurations with M2 connectors are only available in E ic. 4) Eplosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 5) Only in connection with E approval A, B, E or F. ) M2 delivered without cable socket Selection and Ordering data Article No. SITRANS P pressure transmitter for gauge pressure, with PMC connection DS III with PROFIBUS PA (PA) 7 M F DS III with FOUNDATION Fieldbus (FF) 7 M F Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Meas. cell cleaning Silicone oil normal Inert liquid grease-free to cleanliness level 2 Nominal measuring range bar ) (4.5 psi) ) B 4 bar (58 psi) C bar (22 psi) D Wetted parts materials Seal diaphragm Connection shank Hastelloy Stainless steel B Process connection 2) PMC Style Standard: Thread ½" 2 PMC Style Minibolt: front-flush " (minimum span: 500 mbar (7.25 psi), not available with -bar-measuring cell (Option B)) Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, 2 setting for pressure unit: bar Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with compact operating instructions in various EU languages. Eplosion protection None A With ATEX, Type of protection: - "Intrinsic safety (E ia)" B - "Eplosion-proof (E d)" ) D - E na/ic (Zone 2)" 4) E FM + CSA intrinsic safe (is) 5) F With FM + CSA, Type of protection: - "Intrinsic Safe and Eplosion Proof (is + p)" )5) N C Electrical connection / cable entry Female thread M20.5 B Female thread ½-4 NPT C M2 connectors (stainless steel) ) 7) F Display Without display 0 Without visible display (display concealed, setting: bar) With visible display (setting: bar) With customer-specific display (setting as specified, 7 Order code "Y2" required) Included in delivery of the device: Quick-start guide Sealing ring ) Only with "PMC Style Standard"process connection 2) Sealing is included in delivery. ) Without cable gland, with blanking plug 4) Configurations with M2 connectors are only available in E ic. 5) Eplosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505 ) Only in connection with E approval A, B, E or F. 7) M2 delivered without cable socket /80 Siemens FI US Edition

10 Siemens AG 207 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Plug Angled A2 Han 8D (metal, gray) A M2 cable sockets (metal (CuZn)) A50 Rating plate inscription (instead of German) English B French B2 Spanish B Italian B4 Cyrillic (russian) B English rating plate B2 Pressure units in inh 2 0 and/or psi Quality Inspection Certificate (5-point characteristic C curve test) according to IEC Inspection certificate C2 Acc. to EN Factory certificate C4 Acc. to EN "Functional safety (SIL2)" certificate acc. to IEC 508 C20 "Functional safety (SIL2/)" certificate acc. C2 to IEC 508 PED for Russia with initial calibration mark C99 Setting of the upper saturation limit of the D05 output signal to 22.0 ma Degree of protection IP/IP8 D2 (only for M20.5 and ½-4 NPT) Eport approval Korea E Eplosion-proof "Intrinsic safety" to NEPSI (China) E55 ) (only for transmitter 7MF B..) Eplosion protection "Eplosion-proof" E5 ) to NEPSI (China) (only for transmitter 7MF D..) E protection "Zone 2" to NEPSI (China) E57 ) (only for transmitter 7MF E..) E protection E ia", E d" and Zone 2" E58 ) to NEPSI (China) (only for transmitter 7MF R..) Mounting Weldable sockets for standard ½" P0 threaded connection Weldable socket for minibolt connection " P02 (incl. screw 5/-8 UNC-2B and washer) ) Option does not include ATEX approval, but instead includes only the country-specific approval. SITRANS P DS III with PMC connection Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain tet. Measuring range to be set Y0 ) Specify in plain tet (ma. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Stainless steel tag plate and entry in Y5 device variable (measuring point description) Ma. characters, specify in plain tet: Y5:... Measuring point tet (entry in device variable) Y Ma. 27 characters, specify in plain tet: Y:... Entry of HART address (TAG) Y7 Ma. 8 characters, specify in plain tet: Y7:... Setting of pressure indication in pressure Y2 units Specify in plain tet (standard setting: bar): Y2: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H 2 O *), inh 2 O *), fth 2 O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm 2, kg/cm 2, Torr, ATM or % *) ref. temperature 20 C Setting of pressure indication in nonpressure Y22 + units 2) Y0 Specify in plain tet: Y22:... up to... l, m, m, USg,... (specification of measuring range in pressure units "Y0" is essential, unit with ma. 5 characters) Preset bus address Y25 possible between and 2 Ma. 8 characters, specify in plain tet: Y25:... Only "Y0" and "Y2" can be factory preset = available ordering eample Item line: 7MF4-DB20-AB7-Z B line: C + Y0 + Y2 C line: Y0:... 0 bar ( psi) C line: Y2: bar (psi) ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. 2) Preset values can only be changed over SIMATIC PDM. Siemens FI US Edition /8

11 Siemens AG 207 SITRANS P DS III with PMC connection Dimensional drawings 5 4 (5.) (0.) 74 (2.9) 5 (2.) 24 (0.94) 29 (.4) 84 (.) 4 Ø80 (.5) 50 (.97) 2 min. 90 (.54) 2) 5 0 (5.2) H = appro. 7 Space for rotation of housing H 2 2 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland M20,5 or screwed gland ½-4 NPT or M2 conector Protective cover over keys Blanking plug Screw cover - safety bracket (only for type of protection "Eplosion-proof enclosure", not shown in the drawing) Process connection: PMC standard ) Allow appro. 20 mm (0.79 inch) thread length to permit unscrewing 2) 92 mm (. inch) for minimum distance to permit rotation with indicator SITRANS P DS III pressure transmitters for gauge pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an eample of a PMC Style standard flange. In this drawing the height is subdivided into H and H 2. H = Height of the SITRANS P DS III up to a defined cross-section H 2 = Height of the flange up to this defined cross-section Only the height H 2 is indicated in the dimensions of the flanges. M44,25 Ø,4 (.) Ø 2,7 (.05) H 2 D DN PN D H mm (.") appro..8 mm (.4") 20,9 (0.82) Ø, (.44) Ø 58,9 (2.2) ) Ø 8 (0.) 25,4 () 7,8 (0.7) PMC Style minibolt H 2 DN PN D H 2 2. mm (.0") appro.. mm (.") D ) O-ring surface (bore hole Ø 8 mm (0. ) without burr) PMC Style Standard (left) and PMC Style Minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, Mat. No..4404/L /82 Siemens FI US Edition

12 Siemens AG 207 Technical specifications SITRANS P00 for gauge pressure with PMC connection for the paper industry Input Measured variable Gauge pressure (front-flush) Span (fully adjustable) or measuring range, ma. operating pressure and ma. test pressure HART PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring range bar kpa psi bar kpa psi bar kpa psi bar 00 kpa 4.5 psi 4bar 400 kpa 58 psi bar 00 kpa 22 psi SITRANS P00 with PMC connection Ma. operating pressure MAWP (PS) 4bar 400 kpa 58 psi 7bar 0.7 MPa 02 psi 2 bar 2. MPa 05 psi Ma. perm. test pressure bar 00 kpa 87 psi 0 bar MPa 45 psi 2 bar.2 MPa 44 psi Lower measuring limit 00 mbar a/0 kpa a/.45 psia (For PMC-Style Minibolt no span < 500 mbar adjustable) Upper measuring limit 00 % of ma. span Output HART PROFIBUS PA/ FOUNDATION Fieldbus Output signal ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable).55 ma, factory preset to.84 ma - Upper limit (infinitely adjustable) 2 ma, factory preset to 20.5 ma or - optionally set to 22.0 ma Load Without HART communication R B (U H V)/0.02 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC 58-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with ma. supply voltage. Electrical damping (step width 0. s) Set to 2 s ( s) Measuring accuracy Acc. to IEC Reference conditions Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Measuring cell with silicone oil Room temperature 25 C (77 F) Measuring span ratio r (spread, Turn-Down) r = ma. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic -r % - 5<r 00 (0.005 r ) % Influence of ambient temperature (0.08 r + 0.) % (in percent per 28 C (50 F)) Long-term stability (temperature change ± 0 C (± 54 F)) (0.25 r) % in 5 years Effect of mounting position 0. mbar/0.0 kpa/ psi per 0 inclination (zero point correction is possible with position error compensation) Effect of auiliary power supply % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and 0-5 of nominal measuring range FOUNDATION Fieldbus Siemens FI US Edition /8

13 Siemens AG 207 SITRANS P00 with PMC connection SITRANS P00 for gauge pressure with PMC connection for the paper industry Rated conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to eplosion hazard. Measuring cell with silicone oil C ( F) Display readable C ( F) Storage temperature C ( F) Climatic class Condensation Relative humidity % Condensation permissible, suitable for use in the tropics Degree of protection acc. to EN 0529 IP5, IP8, NEMA 4X, enclosure cleaning, resistant to lyes, steam to 50 C (02 F) Electromagnetic Compatibility Emitted interference and interference immunity Acc. to IEC 2 and NAMUR NE 2 Medium conditions Temperature of medium Measuring cell with silicone oil C ( F) Design Weight (without options) Appro. kg (2.2 lb) Enclosure material Stainless steel, mat. no..40/04 Material of parts in contact with the medium Seal diaphragm Hastelloy C27, mat. no Measuring cell filling Silicone oil Surface quality touched-by-media Ra-values 0.8 µm (2 µ inch)/welds Ra. µm (4 µ inch) Power supply U H HART PROFIBUS PA/ FOUNDATION Fieldbus Terminal voltage on transmitter V DC for intrinsically safe operation: V DC Power supply Supplied through bus Separate power supply - Not necessary Bus voltage Without E V With intrinsically-safe operation V Current consumption Ma. basic current ma Start-up current basic current - Yes Ma. fault current in the event of a fault ma Fault disconnection electronics (FDE) available - Yes /84 Siemens FI US Edition

14 Siemens AG 207 SITRANS P00 with PMC connection SITRANS P00 for gauge pressure with PMC connection for the paper industry Certificates and approvals HART PROFIBUS PA/ FOUNDATION Fieldbus Classification according to PED 204/8/EU For gases of fluid group and liquids of fluid group ; complies with requirements of Article 4, paragraph (sound engineering practice) Eplosion protection Intrinsic safety "i" PTB 05 ATEX 2048 Marking II /2 G E ia llc/llb T4/T5/T Ga/Gb Permissible ambient temperature Temperature class T C ( F) Temperature class T C ( F) Temperature class T C ( F) Connection To certified intrinsically-safe circuits with peak values: U i = 0 V, I i = 00 ma, P i = 750 mw, R i = 00 Ω To certified intrinsically-safe circuits with peak values: FISCO supply unit: U i = 7.5 V, I i = 80 ma, P i = 5.2 W Linear barrier: U i = 24 V, I i = 250 ma, P i =.2 W Effective inner capacitance: C i = nf C i =. nf Effective internal inductance: L i = 0.4 mh L i 7 μh Eplosion protection to FM for USA and Canada (cfm US ) Identification (DIP) or (IS); (NI) Certificate of Compliance CL I, DIV, GP ABCD T4... T; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AE ia IIC T4... T; CL I, DIV 2, GP ABCD T4... T; CL II, DIV 2, GP FG; CL III Identification (DIP) or (IS) Certificate of Compliance C CL I, DIV, GP ABCD T4... T; CL II, DIV, GP EFG; CL III; E ia IIC 4... T; CL I, DIV 2, GP ABCD T4... T; CL II, DIV 2, GP FG; CL III Siemens FI US Edition /85

15 Siemens AG 207 SITRANS P00 with PMC connection HART communication HART Ω Protocol HART Version 5. Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with 4 master class 2 (ma.) The address can be set using Configuration tool Local operation (standard setting Address 2) Cyclic data usage Output byte One measured value: 5 bytes Two measured values: 0 bytes Input byte Register operating mode: bytes Reset function due to metering. bytes Device profile PROFIBUS PA Profile for Process Control Devices Version.0, class B Function blocks 2 Analog input - Adaptation to customer-specific process variables Linearly rising or falling characteristic - Electrical damping s adjustable - Simulation function Input /Output - Limit monitoring One upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset and preset Optional direction of counting Simulation function of the register output - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks 2 Pressure transducer block - Monitoring of sensor limits Yes - Specification of a container Ma. nodes characteristic with - Characteristic curve Linear - Simulation function Available Transducer block "Electronic temperature" Simulation function Available FOUNDATION Fieldbus communication Function blocks function blocks analog input, function block PID Analog input - Adaptation to customerspecific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /8 Siemens FI US Edition

16 Siemens AG 207 Selection and Ordering data SITRANS P00 pressure transmitters with PMC connection, single-chamber measuring housing, rating plate inscription in English Article No. with ma / HART 7 M F with PROFIBUS PA 7 M F with FOUNDATION Fieldbus (FF) 7 M F Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid Cleanliness level 2 to DIN 2540 Measuring span bar ) (4.5 psi) B 4 bar (58 psi) C bar (22 psi) D Wetted parts materials Seal diaphragm Measuring cell Hastelloy Stainless steel B Process connection PMC Style Standard: Thread ½" 2 PMC Style Minibolt: front-flush " (minimum span: 500 mbar (7.25 psi), not available with -bar-measuring cell (Option B)) Non-wetted parts materials Stainless steel, deep-drawn and electrolytically 4 polished Version Standard versions Eplosion protection None A With ATEX, Type of protection: - "Intrinsic safety (E ia)" B Zone 20/2/22 2) C E na/nl (Zone 2) ) E With FM + CSA, Type of protection: - "Intrinsic Safe (is)" (planned) 4) M Electrical connection/cable entry Screwed gland M20.5 (polyamide) 5) A Screwed gland M20.5 (metal) B Screwed gland M20.5 (stainless steel) C M2 connectors (without cable socket) F M2 connectors (stainless steel), without cable G socket) ½-4 NPT metal thread ) H ½-4 NPT stainless steel thread ) J SITRANS P00 with PMC connection Selection and Ordering data Article No. SITRANS P00 pressure transmitters with PMC connection, single-chamber measuring housing, rating plate inscription in English with ma / HART 7 M F with PROFIBUS PA 7 M F with FOUNDATION Fieldbus (FF) 7 M F Display Without display, with keys, closed lid With display and keys, closed lid 7) 2 With display and keys, lid with Makrolon pane 4 (setting on HART devices: ma, with PROFIBUS PA and FOUNDATION Fieldbus equipment: pressure units) 7) With display and keys (setting acc. to specifications, Order code "Y2" or "Y22" required), lid with 5 Makrolon pane 7) With display and keys, lid with glass pane (setting on HART devices: ma, with PROFIBUS PA and FOUNDATION Fieldbus equipment: pressure unit) 7) With display (setting acc. to specifications, Order 7 code "Y2" or "Y22" required), lid with glass panel 7) Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: Quick-start guide Sealing ring ) Only with "Standard" process connection" 2) Not in conjunction with electrical connection option A. ) Only available together with electrical connection options B, C or G. 4) Eplosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 5) Only together with HART electronics. ) Without cable gland. 7) Display cannot be turned. Siemens FI US Edition /87

17 Siemens AG 207 SITRANS P00 with PMC connection Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Cable socket for M2 plug Stainless steel A5 Rating plate inscription (instead of English) German B0 French B2 Spanish B Italian B4 English rating plate B2 Pressure units in inh 2 0 and/or psi Quality Inspection Certificate (5-point characteristic C curve test) according to IEC Inspection certificate C2 Acc. to EN Factory certificate C4 Acc. to EN Setting of the upper saturation limit of the D05 output signal to 22.0 ma Degree of protection IP5/IP8 D2 (only for M20.5 and ½-4 NPT) Mounting Weldable sockets for standard ½" P0 threaded connection Weldable socket for minibolt connection " (incl. screw 5/-8 UNC-2B and washer) P02 Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain tet. Measuring range to be set Y0 ) Specify in plain tet (ma. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Stainless steel tag plate and entry in Y5 device variable (measuring point description) Ma. characters, specify in plain tet: Y5:... Measuring point tet (entry in device variable) Y Ma. 27 char., specify in plain tet: Y:... Entry of HART address (TAG) Y7 Ma. 8 char., specify in plain tet: Y7:... Setting of pressure indication in Y2 pressure units Specify in plain tet (standard setting: bar): Y2: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H 2 O *), inh 2 O *), fth 2 O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm 2, kg/cm 2, Torr, ATM or % *) ref. temperature 20 C Setting of pressure indication in non-pressure Y22 + units 2) Y0 Specify in plain tet: Y22:... up to... l, m, m, USg,... (specification of measuring range in pressure units "Y0" is essential, unit with ma. 5 characters) Preset bus address Y25 possible between and 2 Specify in plain tet: Y25:... Only "Y0" and "Y2" can be factory preset = available ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. 2) Preset values can only be changed over SIMATIC PDM. /88 Siemens FI US Edition

18 Siemens AG 207 Dimensional drawings SITRANS P00 with PMC connection Ø 9 (.58) (2.) H 2 = appro.,8 (.4) H = appro. 20 (4.72) 9 (2.72) 2 (.02) 2,5 (.04) 82 SITRANS P00 pressure transmitters for gauge pressure, with PMC connection, dimensions in mm (inch) The diagram shows a SITRANS P00 with an eample of a flange. In this drawing the height is subdivided into H and H 2. H = Height of the SITRANS P00 up to a defined cross-section H 2 = Height of the flange up to this defined cross-section Only the height H 2 is indicated in the dimensions of the flanges. PMC Style Standard H 2 DN PN D H mm (.") Appro..8 mm (.4 ) M44,25 Ø,4 (.) Ø 2,7 (.05) D 20,9 (0.82) Ø, (.44) Ø 58,9 (2.2) ) Ø 8 (0.) 25,4 () 7,8 (0.7) PMC Style Mini bolt H 2 DN PN D H 2 2. mm (.0") Appro.. mm (. ) D ) O-ring surface (bore hole Ø 8 mm (0. ) without burr) PMC Style Standard (left) and PMC Style Minibolt (right) weldable sockets, dimensions in mm (inch) Material: Stainless steel, mat. No / L Siemens FI US Edition /89

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 SITRANS P300 and DS III series with PMC connection Technical description Benefits High quality and long life High reliability even under etreme chemical and mechanical loads, e.g.

More information

SITRANS P. Transmitters for level. Introduction 1/42. Application

SITRANS P. Transmitters for level. Introduction 1/42. Application Introduction HK series S series Fig. / transmitters for level, with built-in analog indicator or digital display Application The transmitter with mounting flange measures the level of corrosive and non-corrosive

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

Temperature Measurement

Temperature Measurement Siemens AG 00 - Transmitter, two-wire system and - Field indicator for 4 to 0 ma Overview Our field devices for heavy industrial use HART, Universal 4 to 0 ma, universal Field indicator for 4 to 0 ma signals

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Temperature Measurement

Temperature Measurement Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Temperature Measurement

Temperature Measurement Siemens AG 017 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,

More information

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Temperature Measurement Transmitter for field mounting/field indicator

Temperature Measurement Transmitter for field mounting/field indicator Siemens AG 017 SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 0 ma Overview Our field devices for heavy industrial use HART, Universal 4 to 0 ma, universal Field indicator

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

Extractive continuous process gas analysis Series 6 CALOMAT 62

Extractive continuous process gas analysis Series 6 CALOMAT 62 Siemens AG 208 Overview The gas analyzer is primarily used for quantitative determination of one gas component (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 265GS Gauge Model 265AS Absolute standard overload Base accuracy : ±0.04% Span limits 0.2 to 60000kPa; 0.8inH2O to 8700psi 0.3 to 3000kPa abs;

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm Electronic pressure measurement Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm WIKA data sheet PE 86.11 Applications Process engineering Pharmaceutical industry

More information

Data Sheet SS/265VS-EN_1

Data Sheet SS/265VS-EN_1 Contents Data Sheet Model 265VS Absolute Series 2600T Pressure Transmitters Engineered solutions for all applications Maximum overload capability up to 41 MPa, 5945 psi Base accuracy ± 0.04 % Span limits

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

SMART PRESSURE TRANSMITTER APC-2000ALW

SMART PRESSURE TRANSMITTER APC-2000ALW SMART PRESSURE TRANSMITTER APC-2000ALW Digital PROFIBUS PA signal 4 20, 0 20 or 0 5 m A output signal + HART protocol Programmable range, zero shift, characteristic and damping ratio with local panel keys

More information

Pressure and level transmitter PASCAL CV LEVEL,

Pressure and level transmitter PASCAL CV LEVEL, Pressure and level transmitter PASCAL CV LEVEL, temperature compensation by LTC-technology,Type series CV311. L Features Modular pressure and level transmitter temperature compensation up to 0.1 mbar /

More information

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application

600T EN Series Pressure Transmitters. Specification sheet. Model 624ES gauge/absolute with direct mount seal for pulp & paper application Specification sheet 6T EN Series Pressure Transmitters Model 6ES gauge/absolute with direct mount seal for pulp & paper application Base accuracy : ±.7% Reliable inductive sensing system coupled with the

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature SITRANS T measuring instruments for temperature /2 Product overview / SITRANS T transmitters for mounting in sensor head / SITRANS TK PA, with PROFIBUS connection /8 SITRANS TH100, two-wire system (Pt100)

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

High-quality pressure transmitter For general industrial applications Model S-20

High-quality pressure transmitter For general industrial applications Model S-20 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications

More information

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview Overview Design and mode of operation Like the other units in the range, the SITRANS FVA250 operates according to the variablearea flow tube principle: the flowing medium lifts the conical float in the

More information

ProcessMaster, HygienicMaster FEX300, FEX500

ProcessMaster, HygienicMaster FEX300, FEX500 SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview Flow Measurement Flowmeter SITRANS FC40 Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information