1 EnergyMetering Bulk water meter WPD (type Woltman parallel, 1) WPHD (type Woltman parallel, ) WSD (type Woltman perpendicular ) All that c ou n t s.

2 WPD / WPHD Woltman meter with parallel turbine shaft The ZENNER Bulk water meter WPD / WPHD is specially constructed for the measuring of high flow rates with a mainly constant flow rate profile. Due to the robust design, WPD / WPHD can cover a wide measuring range and provide accurate measuring results over a long period. So it covers almost all measuring tasks in the drinking water supply and distribution. WPD / WPHD Bulk water meter WPD ( 1), WPHD ( ) Replacable metrological unit (according to european MID) Prepared for remote meter reading Product characteristics Replacable metrological unit (according to european MID) Floodproof (IP6) hermetically sealed glass/copper register Low starting flow, high overload security Wide measuring range, small pressure loss Hydraulic bearing relieve Longterm measuring stability Swirlreducing inlet No straight inlet or outlet needed () according to OIML R9 and DIN EN 11 Materials and coating approved in accordance with KTW / W 270 Optional WS overall length for, 6, 0 and 0 available Optional ISO length for, 0 and 0 available Approved in accordance with MID and OIML 2 The housing of the WPD / WPHD was flowoptimized. The mesuring insert was newly constructed as a replacable metrological unit according to european MID. In combination with an uptodate bearing of the impeller a good linearity and longterm stability of the error curve can be achieved. The robust copperglassregister is nondiffusive and protected against condensation. It also works reliably under the hardest conditions (e.g. in flooded pits or shafts). Applications For the mesuring of high flow rates For horizontal or vertical installation For cold water up to C AMR options Retrofittable with up to two reedsensors Retrofittable with stationary GSM system Serially equipped with counication interface for: Electronic pulser Wired Mbus Radio via Wireless MBus according to OMS (Open Metering System) Radio via LPWAN (LoRaWAN, SIGFOX) TM

3 Technical Data WPD ( 1) Nominal diameter Permanent flow Q Attainable measuring range Q3/Q1 R R12H RH RH RH RH R31H R31H R31H Standard measuring range (*) Q3/Q1 R Overload flow (**) Q 31, , Minimum flow (**) Q1 0,2/0, 0,/0,63 0,/0,6 0,63/1,01 0,63/1,02 1,0/1,9 1,0/1,60 2,/3,97 Transitional flow (**) Q2 0,/0,63 0,6/1,02 0,6/1,03 1,01/1,61 1,01/1,62 1,6/2, 1,6/2,,0/6,3 Pressure loss at Q3 p MPa 0,01 0,0 0,012 0,01 0,01 0,011 0,012 0,026 l/h min l max m³ C 0,1 0,1 0,1 0,1 0,1 0,1 Startup flow rate Display range Temperature range Operating pressure, max. R0H/63V R0H/63V R0H/63V R0H/63V R0H/63V R0H/63V R0H/63V R0H/63V 7,7 7,7 9. 0,1 0,1 MAP bar Pulse value Reed l/imp. 0/00 0/00 0/00 0/00 0/00 0/00 Pulse value modulator disc l/imp. 0 Pressure loss at Q3 p bar 0,1 0, 0,12 0,1 0,1 0,11 0,12 0,1 Mechanical environ mental condition Climatic condition (****) C Flow profile sensitivity Nominal diameter Overall length (*) L / Height H Height H H1+H /00 00/.000 Weight and dimensions: Total height approx. (***) Installation height of the measuring unit H3 0 0 Typical accuracy curve WSD WPD/WPHD Flange diameter D Bolt circle diameter D Number of bolts pcs. Screw size M M M M M M M 0 Bolt diameter Weight approx. kg,, 11, 13, 13,,9 20,1 31, + pressure loss [bar] Accuracy [%] (*) Other measuring ranges (R) on request (**) Values refer to standard measuring range (***) Total height WPDE/WPHDE + 2 (****) Condensation possible Q1 Q2 Q3 Q Flow rate [] flow rate [m3/h] 3 Accuracy Curve

4 Technical Data WPHD ( ) Nominal diameter 2 2 Permanent flow Q Attainable measuring range Q3/Q1 R R0H R0H R0H R0H R0H R0H Standard measuring range (*) R0H/63V Q3/Q1 R R0H/63V R0H/63V R0H/63V R0H/63V R0H/63V Overload flow (**) Q Minimum flow (**) Q1,0/6,3,0/6,36 6,3/,0 6,3/,1,0/1,7,0/1, Transitional flow (**) Q2 6,/, 6,/,17,0/,0,0/,1,0/2,,0/2, Pressure loss at Q3 p MPa 0,009 0,009 0,00 0,00 0,00 0,00 0 Startup flow rate Display range l/h min l max m³ ,1 Temperature range Operating pressure, max. C 0,1 0,1 0,1 0,1 0,1 MAP bar l/imp. 00/ / / / / /.000 Pulse value Reed Pulse value modulator disc l/imp p bar 0,09 0,09 0,0 0,0 0,0 0,0 Mechanical environmental condition Climatic condition (****) C Flow profile sensitivity Nominal diameter 2 2 Overall length (*) L Height H Height H Pressure loss at Q3 Weight and dimensions: Total height approx. (***) H1+H Installation height of the measuring unit H Flange diameter D Bolt circle diameter D1 WPD/WPHD 29 Typical accuracy curve WSD Number of bolts pcs Screw size Bolt diameter 2 2 Weight approx. kg pressure loss [bar] Accuracy [%] (*) Other measuring ranges (R) on request (**) Values refer to standard measuring range (***) Total height WPDE/WPHDE + 2 (****) Condensation possible Q1 Q2 Q3 Q Flow rate [] Accuracy Curve flow rate [m3/h]

5 H3 H1 H2 D1 D L Safety device Marking connection interface User safety for Reed switch Safety device Marking connection interface User safety for Reed switch M ZENNER 12 (WSD ) ZENNER 1

6 AMR Options All Woltman meters are equipped with the ZENNER 6digitrollers register with modulator disc. Combinated with the ZENNER EDC counication module the modulator disc enables a nonreactive scanning for remote meter reading via radio (wireless MBus according to OMS), MBus or LPWAnetworks in the Internet of Things. The Woltman meters WPD / WPHD and WSD are prepared for the installation of EDC counication modules as a standard. The EDC counication modules are designed for outdoor use and can be retrofitted at any time. In addition the meters are retrofittable with up to two reedpulsers. This enables the integration in an MBus system or the connection of a GSM datalogger. Interface for up to two mechanical reed pulser: Integration into an Mbussystem Learn more about MBus: Connection of a GSM datalogger Leak detection remote readout via GSM Pipe burst Error detection Learn more about GSM: 6

7 Counication interface for EDC modules for electronic pulser, MBus or radio Water meters with EDCmodules provide the following smart metering functions: Selfmonitoring Tampering detection Dismounting of module and meter detection Reverse water flow detection Leakage detection Meter Stop detection Meter oversized detection Meter undersized respectively pipe burst detection Walkby / Driveby Radio System OPERA Wireless MBus radio technology according to OMS Unidirectional radio technology according to EN 1377 and OMS specification Compatible with several thirdparty software systems Frequency: 6MHz Power: 2mW at 6 MHz Operating time up to 1 years Learn more about wireless MBus: Stationary Radio System (Internet of Things) Bidirectional LPWAN radio technology TM (Low Power Wide Area Network) Integration of meters into the Internet of Things (IoT) Use of the international LoRaWAN standard Use of the international SIGFOX standard Learn more about Internet of Things: 7

8 WSD Woltman meter with perpendicular turbine shafts The impeller axis of the WSD is aligned perpendicular to the tube axis. Due to the minmal friction, extremly low starting values can be achieved. Thanks to its design advantages, the Woltmann meter type WSD is an ideal choice especially with fluctuating flow rates and different pressure conditions. WSD Bulk water meter type Woltman perpendicular Replacable metrological unit (according to european MID) Prepared for remote meter reading Product characteristics Replacable metrological unit (according to european MID) Floodproof (IP6) hermetically sealed glass/copper register" Low starting flow, high overload security Hydraulic bearing relieve Longterm measuring stability Swirlreducing inlet No straight inlet or outlet needed () according to OIML R9 and DIN EN 11 Materials and coating approved in accordance The hydrodynamic optimized impeller is driven reliably even at low flow rates. Also under the highest loads it has enough reserve to detect even flow rate peaks. The specially enhanced bearing of the impeller causes low friction and guarantees a long service lifetime of the meter. The robust copperglassregister is nondiffusive and protected against condensation. It also works reliably under the hardest conditions (e.g. in flooded pits or shafts). AMR options Retrofittable with up to two reedsensors Retrofittable with stationary GSM system Serially equipped with counication interface for: Electronic pulser Wired Mbus Radio via Wireless MBus according to OMS (Open Metering System) Radio via LPWAN (LoRaWAN, SIGFOX) with KTW / W 270 Optional WP overall length for, 0 and 0 available Optional ISO length for, 0 and 0 available Approved in accordance with MID and OIML Applications For the mesuring of fluctuating flow rates For horizontal installation For cold water up to C TM

9 Technical Data WSD Nominal diameter Permanent flow Q Measuring range Q3/Q1 R H H H H H H H H Standard measuring range * Q3/Q1 R R0H R0H R0H R0H R0H R0H R0H R0H Overload flow ** Q 31,2 7,7 7, , 0 Minimum flow** Q1 0,2 0, 0, 0,63 0,63 1 2, Transitional flow ** Q2 0, 0,6 0,6 1,01 1,01 1,6 6, Pressure loss at Q3 p MPa 0,0 0,0 0,0 0,0 0,0 0,03 0,01 0,03 l/h min l max m³ Temperature range T C 0,1 0,1 0,1 0,1 0,1 0,1 Operating pressure Starting flow Display range ,1 0,1 MAP bar Pulse value Reed l/imp. 0/00 0/00 0/00 0/00 0/00 0/00 0/00 0/00 Pulse value modulator disc l/imp. p bar Climatic condition (****) C Flow profile sensitivity L /270 /270 22/ 2/ Height H Height H H1+H H Pressure loss at Q3 Mechanical environmental condition Weight and dimensions: Diameter Overall length* Total height approx.*** Removal height measuring unit Typical accuracy curvedwsd WPD/WPHD Flange diameter Bolt circle diameter D Number of bolts pcs. 12 Screw size M M M M M M 0 0 Bolt diameter Weight approx. kg 12/13 12/13 1 /21 21 /2 9 + pressure loss [bar] Accuracy [%] (*) Other measuring ranges (R) on request (**) Values refer to standard measuring range (***) Total height WSDE + 2 (****) Condensation possible Q1 Q2 Q3 Q Flow rate [] flow rate [m3/h] 9 Accuracy Curve

10 H3 H1 H2 D D1 L Safety device Marking connection interface User safety for Reed switch M ZENNER 12 (WSD ) ZENNER 1 Konturen Bemaßung 0,3

11 SMART METERS NOW GOING ONLINE Stationary LPWAN wireless system TM For remote wireless reading via the Internet of Things The new ZENNER counication modules turn the integration of water meters, heat meters, heat cost allocators and other measurement devices with wireless functionality into the Internet of Things into reality. By using LPWAN (Low Power Wide Area Network) technology and the internationally established counication standards LoRaWANTM and SIGFOX meters can now be read more frequently, more quickly and more efficiently. This allows the efficient and extensive fixednetwork reading of consumption measurement devices with maximum flexibility and minimum effort. Learn more! 3 radio im Überblick facebook.com/zennernews twitter.com/zenner_news 11

12 Römerstadt 6 D66121 Saarbrücken Telephone Telefax info@zenner.com Internet Subject to modifications and errors excepted. Any liability for misprints excluded. SAP119_171122_EN ZENNER International GmbH & Co. KG

EDC communication module

EDC communication module EnergyMetering EDC communication module Water meter clip-on module for secure remote reading for integration of water meters in Smart Metering AMR/AMI Systems All that counts. EnergyMetering EDC communication

More information

Residential Water Meters

Residential Water Meters EnergyMetering Residential Water Meters Multi-jet wet dial meters Positive displacement meters All that counts. Multi-jet wet dial meters Options of the D-register at a glance Register and smart metering

More information

EDC communication module

EDC communication module EnergyMetering EDC communication module Water meter clip-on module for secure remote reading for integration of water meters in Smart Metering AMR/AMI Systems All that counts. EnergyMetering EDC communication

More information

Energy Technology. AMR Systems

Energy Technology. AMR Systems Energy Technology AMR Systems Bus systems Wireless M-Bus radio system LPWAN radio system (LoRaWAN, SIGFOX) Stationary GSM system Electronic components Software solutions 1 2 ZENNER AMR Systems Flexible,

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

MID MP-01, MP WATER MEASUREMENT

MID MP-01, MP WATER MEASUREMENT FROM METERING TO DATA MANAGEMENT WATER MP-0, MP30-0 PROPELLER WATER METER WITH VERTICAL ROTOR AXIS DN40 DN0 MID APPROVED MP-0 is a dry Woltmant propeller water meter with the vertical rotor axis which

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h APPLICATION Ray is a fully electronic multi-jets compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors.

More information

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic

More information

SN+ MID MASTER + APPLICATION WATER METERS

SN+ MID MASTER + APPLICATION WATER METERS SMART THINKING WATER METERS MASTER + SINGLE-JET DRY WATER METERS DN25, DN32, DN40 MID R 100 Master+ is a single-jet dry meter intended to measurement of quantity of consumption. Thank to modern construction

More information

Release A Member of the

Release A Member of the Release 4.02 A T u n e d GRID M e a s u r e A Member of the GRID GRID The OCTAVE Ultrasonic Meters A revolutionary, precise and ultra reliable ultrasonic bulk water meter with no moving parts. With superior

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Static Meters Portfolio ULTRAHEAT/ ULTRACOLD and ULTRAWATER The best of Landis+Gyr Ultrasonic Static Meters, for

More information

NUBIS. R t o WATER MEASUREMENT

NUBIS. R t o WATER MEASUREMENT FROM METERING TO DATA MANAGEMENT WATER NUBIS PROPELLER WATER METER WITH HORIZONTAL IMPELLER AXLE MID APPROVED Nubis is propeller, dry water meter Woltman s type, with horizontal impeller axle, parallel

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

flowiq 3100 Data sheet

flowiq 3100 Data sheet Data sheet flowiq 3100 Pinpoint accuracy Vacuum sealed construction Drive-by or network Long range Long life Built-in Wireless M-Bus Simple installation Contents Approved meter data 4 Material 4 Technical

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1 Data sheet / 3.3.2017 - V 2.1 Electronic water meter Q water 5.5 Electronic MID-conform water meter for determining water consumption in water supply systems The electronic water meter Q water 5.5 has

More information

wprime TM Series 280W-CI ULTRASONIC WATER METER

wprime TM Series 280W-CI ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water

More information

Nubis propeller water meter with horizontal impeller axle

Nubis propeller water meter with horizontal impeller axle Nubis propeller water meter with horizontal impeller axle Nubis is propeller, dry water meter Woltman s type, with horizontal impeller axle, parallel to pipe axles. Nubis water meters are characterized

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies A T u n e d M e a s u r e A Member of the Integrated Metering Technologies AMR Ready ARAD 3G easy connection to any automated metering reading system. No Moving Parts No wear - Therefore low maintenance.

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-R Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS Design IEC870-6 EW447A0100 26757950 2252 00.02 Type440 Umgebungsklasse: C env: 5 C...105 C Δp: 3K...100K q: 1,5m 3 /h q: 0,03m 3 /h q: 3,0m 3 /h M-Bus kwh 2002 er: 5 C...90 C DN15 PN16 Rücklauf Pt500 Kl.

More information

flowiq 3100 Data sheet

flowiq 3100 Data sheet Data sheet Nominal flow from 1.6 m³/h up to 100 m³/h Approved with dynamic range up to R400 'Drive-by', network or IoT Pinpoint accuracy Designed for operation in submerged environments Integrated communication

More information

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 8452/2HHP. The engineer's choice Product Data Sheet 8452/2HHP The engineer's choice 8452/2HHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2

More information

EverBlu. Wireless fixed data collection system

EverBlu. Wireless fixed data collection system Solution EverBlu Wireless fixed data collection system > Automatic daily meter reads > Graphical data analysis > Reliable self-healing wireless mesh network > Suitable for urban, suburban and rural environments

More information

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS Faster accurate information with Enware Smart Mobile Metering Providing the ability to collect

More information

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR E550 Series 2 Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E550 Series 2, the latest

More information

MULTICAL 21 & flowiq 2101

MULTICAL 21 & flowiq 2101 Data Sheet MULTICAL 21 & flowiq 2101 Pinpoint accuracy Approved with dynamic range up to R400 Drive-by, network or IoT Temperature measurement Low leakage limit Long range Long life Simple installation

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR E550 Series 2 Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E550 Series 2, the latest

More information

Product Data Sheet 622/2HHP-021

Product Data Sheet 622/2HHP-021 The engineer's choice 622/2HHP-021 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. Ultrasonic flow sensor Compact design D a t a s h e e t Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 Application TS 27.01 109 DS/EN

More information

Physikalisch-Technische Bundesanstalt

Physikalisch-Technische Bundesanstalt R3-0033 Braunschweig und Berlin Member State of OIML Germany OIML CERTIFICATE OF CONFORMITY Issuing Authority Name: Address: Person responsible: Bundesallee 100, 38116 Braunschweig Dr. Gudrun Wendt Applicant

More information

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation 07EN March 0 Sanitary water meters GE55- series 00A/ Qualitative error diagram % error 5 0 - - - - -5 Q Q Q Q GE55Y90 GE55Y9 Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Description Single-jet dry

More information

A T u n e d M e a s u r e

A T u n e d M e a s u r e A T u n e d M e a s u r e AMR Ready ARAD 3G built-in and Easy connection to any automated metering reading system. No Moving Parts No wear - Therefore low maintenance. ARAD is proud to introduce the OCTAVE,

More information

OIML CERTIFICATE OF CONFORMITY

OIML CERTIFICATE OF CONFORMITY Member State of OIML Germany OIML CERTIFICATE OF CONFORMITY Issuing Authority Name: Address: Person responsible: Physikalisch-Technische Bundesanstalt Bundesallee 100, 38116 Braunschweig Dr. M. Rinker

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow

More information

The innovative way forward symphonic sensor net radio system

The innovative way forward symphonic sensor net radio system The innovative way forward symphonic sensor net radio system Radio system technology The symphonic sensor net radio system Applications at a glance Heat cost allocation meter doprimo 3 radio net Smoke

More information

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications Flow sensor HVAC 100 (548000) Instruction for use Imprint: Copyright 2017 - all rights reserved Version 547996.02 Subject to modifications Important Information These instructions for use must be read

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 8214 J/2H4P. The engineer's choice Product Data Sheet 8214 J/2H4P The engineer's choice 8214 J/2H4P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface

More information

OPTIFLUX 2000 Technical Datasheet

OPTIFLUX 2000 Technical Datasheet OPTIFLUX 2000 Technical Datasheet Electromagnetic flow sensor For all water and wastewater applications Wide range of approvals for potable water Robust, fully welded construction The documentation is

More information

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. ULTRAFLOW Cooling flow sensor Ultrasonic flow sensor Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity Application ULTRAFLOW type 65-T is a static

More information

Product Data Sheet DV4112/2NP-201

Product Data Sheet DV4112/2NP-201 The engineer's choice DV4112/2NP-201 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical

More information

Technical Description. flowiq Water Meter

Technical Description. flowiq Water Meter Technical Description flowiq 3100 Water Meter TECHNICAL DESCRIPTION flowiq 3100 2 Kamstrup A/S Technical Description 5512-1242_H1_GB 02.2018 flowiq 3100 TECHNICAL DESCRIPTION Contents 1 General description...

More information

Product Data Sheet 8214 J/2H4P

Product Data Sheet 8214 J/2H4P The engineer's choice 8214 J/2H4P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Product Data Sheet 3252J/2H3PU

Product Data Sheet 3252J/2H3PU 3252J/2H3PU INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy. Electricity Meters IEC INDUSTRIAL+COMMERCIAL Landis+Gyr Dialog ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA Frequency Nominal Frequency f n 50 or 0 Hz tolerance ± 2% IEC-specific data Current Nominal Current

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 6314/2TDHP. The engineer's choice Product Data Sheet 6314/2TDHP The engineer's choice 6314/2TDHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2

More information

2017. 05.17 www.spic.co.kr E-mail : spic@spic.co.kr Contents Company Profile Products AMR System & Case Company 1. Name : Shinhan Precision Co., Ltd. 2. Location : Incheon, Republic of Korea 3. Site :

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Product Data Sheet 8452/2 GHHP

Product Data Sheet 8452/2 GHHP 8452/2 GHHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3

More information

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110 Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit

More information

SONO 1500 CT Ultrasonic flow sensor

SONO 1500 CT Ultrasonic flow sensor Data sheet SONO 1500 CT Ultrasonic flow sensor Description/Application MID examination certificate no.: DE-09-MI004-PTB011 The SONO 1500 CT is an ultrasonic flow sensor especially designed for heating,

More information

Heat meter Q heat 5 US

Heat meter Q heat 5 US Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement

More information

Speed sensors for general applications:

Speed sensors for general applications: Speed Senss speed senss The contact-free speed senss of the HSS series detect the movement of ferromagnetic structures, such as gear wheels, gear rims perfated discs, using the changes in magnetic flux.

More information

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110 Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit

More information

Fluxi 2000/TZ. Turbine Gas Meter

Fluxi 2000/TZ. Turbine Gas Meter Fluxi 000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght. Electricity Meters IEC INDUSTRIAL+COMMERCIAL Landis+Gyr Dialog ZMG310AR/CR TECHNICAL DATA Frequency Nominal Frequency fn 50 or 60 Hz tolerance ± 2 % Mesurement Accuracy Accuracy ZMG310xR active energy

More information

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour. Electricity Meters IEC/MID INDUSTRIAL+COMMERCIAL Landis+Gyr Dialog ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA IEC-specific data Current Nominal Current I n 1 A, 5 A, 5 1 A Maximal Current I max metrological

More information

flowiq 3101 DATA SHEET

flowiq 3101 DATA SHEET Ultrasonic measurement Pinpoint accuracy Longevity Long range Leak detection Vacuum-sealed construction Lead-free and certified to NSF/ANSI61 Electronic ultrasonic meter for cold residential water Ultrasonic

More information

Product Data Sheet 3254 J/2H3P

Product Data Sheet 3254 J/2H3P 3254 J/2H3P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

Technical Information HOT WATER. RUBY Woltman Turbine Meters WPDH, WSDH, SMQ Velocity Measuring Units

Technical Information HOT WATER. RUBY Woltman Turbine Meters WPDH, WSDH, SMQ Velocity Measuring Units Technical Information HOT WATER RUBY Woltman Turbine Meters WPDH, WSDH, SMQ Velocity Measuring Units VD 2-301 e 10.2001 1. Introduction 3 1.1 Heating supply applications 1.2 Your benefits 1.3 Operating

More information

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water S-band Magnetron GENERAL DESCRIPTION is a mechanical tuned pulsed type S-band magnetron intended primarily for linear accelerator. It is water cooled and has circle waveguide output type. It is designed

More information

ULTRAFLOW TS Application OIML R75 DS/EN 1434

ULTRAFLOW TS Application OIML R75 DS/EN 1434 ULTRAFLOW Ultrasonic flow meter Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 TS 27.01 109 DS/EN 1434 Application ULTRAFLOW

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Electronic device for recording the share of heat output by radiators.

Electronic device for recording the share of heat output by radiators. Data sheet / 7.5.2018 - V 2.6 Q caloric 5.5 Electronic device for recording the share of heat output by radiators. In terms of measuring technology, the Q caloric 5.5 is 100% compatible with the Q caloric

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

ABSOLUTE ROTARY ENCODER SSI

ABSOLUTE ROTARY ENCODER SSI Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet RER225-63/18/2TDO- 406 Product Data Sheet RER225-63/18/2TDO- 406 The engineer's choice RER225-63/18/2TDO-406 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data

More information

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General Electricity Meters IEC INDUSTRIAL+COMMERCIAL Dialog ZMD310AT/CT TECHNICAL DATA Maximal Current I max metrological selectable 40, 60, 80, 100, 120 A thermal 120 A Short Circuit 10 ms 5000 A Measurement

More information

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet RG160-28/18N/2TDPU-331 RG160-28/18N/2TDPU-331 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating

More information

SCHMIDT Flow Sensor SS Quick Guide

SCHMIDT Flow Sensor SS Quick Guide SCHMIDT Flow Sensor SS 20.600 Quick Guide SCHMIDT Flow Sensor SS 20.600 Table of Contents 1 Important information... 3 2 Application range... 3 3 Assembly... 4 4 Electrical connection... 6 5 Commissioning...

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Circular Cold Saws and Systems for every application. Competence in Circular Cold Sawing Technology

Circular Cold Saws and Systems for every application. Competence in Circular Cold Sawing Technology Circular Cold Saws and Systems for every application Competence in Circular Cold Sawing Technology 2 VMS-Range Vertical Circular Cold Saws Manual, semi-automatic and automatic machines Robust and durable.

More information

EC type-examination certificate UK/0126/0087 Revision 3

EC type-examination certificate UK/0126/0087 Revision 3 UK/0126/0087 MI-001 EC type-examination certificate UK/0126/0087 Revision 3 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments

More information