Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line"

Transcription

1 Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line Min Gyu Hyeon, 1 Hyung-Jin Kim, 2 Beop-Min Kim, 1,2,4 and Tae Joong Eom 3,5 1 Department of Biomicro system Engineering, Korea University, Seoul, South Korea 2 Department of Bio-convergence Engineering, Korea University, Seoul, South Korea 3 Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, Gwangju, South Korea 4 5 Abstract: We propose a spectral domain optical coherence tomography (SD-OCT) system that uses a single line-scan detection scheme for balanced detection. Two phase-opposed spectra, generated by two optical fiber couplers, were detected by using a spectrometer with fast optical switching. A 2.69 km optical fiber was introduced to provide a proper time delay to prevent phase errors caused by the difference in measurement time between the two opposing spectra and unstable output voltages for controlling the galvano-scanner. Hence, a phase difference of π was obtained between the spectra over the sample depth without a phase error, which improved sensitivity by approximately 6 db compared to that of conventional SD-OCT. We directly showed and compared the OCT images before and after applying the proposed balanced detection method in a phantom and in vivo sample Optical Society of America OCIS codes: ( ) Optical coherence tomography; ( ) Buffers, couplers, routers, switches, and multiplexers; ( ) Medical and biological imaging. References and links 1. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and A. Et, Optical coherence tomography, Science 254(5035), (1991). 2. J. G. Fujimoto, Optical coherence tomography for ultrahigh resolution in vivo imaging, Nat. Biotechnol. 21(11), (2003). 3. A. G. Podoleanu, Unbalanced versus balanced operation in an optical coherence tomography system, Appl. Opt. 39(1), (2000). 4. A. M. Rollins and J. A. Izatt, Optimal interferometer designs for optical coherence tomography, Opt. Lett. 24(21), (1999). 5. K. Takada, Noise in optical low-coherence reflectometry, IEEE J. Quantum Electron. 34(7), (1998). 6. A. Bradu and A. G. Podoleanu, Fourier domain optical coherence tomography system with balance detection, Opt. Express 20(16), (2012). 7. W.-C. Kuo, C.-M. Lai, Y.-S. Huang, C.-Y. Chang, and Y.-M. Kuo, Balanced detection for spectral domain optical coherence tomography, Opt. Express 21(16), (2013). 8. W.-C. Kuo, Y.-S. Lai, C.-M. Lai, and Y.-S. Huang, Balanced detection spectral domain optical coherence tomography with a multiline single camera for signal-to-noise ratio enhancement, Appl. Opt. 51(24), (2012). 9. H. Wang, Y. Pan, and A. M. Rollins, Extending the effective imaging range of Fourier-domain optical coherence tomography using a fiber optic switch, Opt. Lett. 33(22), (2008). 10. S.-W. Lee, H.-W. Jeong, and B.-M. Kim, High-speed spectral domain polarization- sensitive optical coherence tomography using a single camera and an optical switch at 1.3 µm, J. Biomed. Opt. 15(1), (2010). 11. K. S. Park, W. J. Choi, T. J. Eom, and B. H. Lee, Single-camera polarization-sensitive full-field optical coherence tomography with polarization switch, J. Biomed. Opt. 18(10), (2013). 12. J. Ai and L. V. Wang, Spectral-domain optical coherence tomography: Removal of autocorrelation using an optical switch, Appl. Phys. Lett. 88(11), (2006). (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23079

2 13. R. Huber, M. Wojtkowski, and J. G. Fujimoto, Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography, Opt. Express 14(8), (2006). 14. D. Nankivil, A.-H. Dhalla, N. Gahm, K. Shia, S. Farsiu, and J. A. Izatt, Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 khz imaging with a 100 khz source, Opt. Lett. 39(13), (2014). 15. A.-H. Dhalla, K. Shia, and J. A. Izatt, Efficient sweep buffering in swept source optical coherence tomography using a fast optical switch, Biomed. Opt. Express 3(12), (2012). 16. J. Zhang, J. Jing, P. Wang, and Z. Chen, Polarization-maintaining buffered Fourier domain mode-locked swept source for optical coherence tomography, Opt. Lett. 36(24), (2011). 17. M. Gora, K. Karnowski, M. Szkulmowski, B. J. Kaluzny, R. Huber, A. Kowalczyk, and M. Wojtkowski, Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 khz with adjustable imaging range, Opt. Express 17(17), (2009). 18. Y. Chen, D. M. de Bruin, C. Kerbage, and J. F. de Boer, Spectrally balanced detection for optical frequency domain imaging, Opt. Express 15(25), (2007). 19. B. Baumann, M. Pircher, E. Götzinger, and C. K. Hitzenberger, Full range complex spectral domain optical coherence tomography without additional phase shifters, Opt. Express 15(20), (2007). 20. H.-W. Jeong, J.-G. Lim, H.-J. Kim, W. Chung, and B.-M. Kim, Complex artifact suppression using vestigial sideband filter in Fourier-domain optical coherence tomography, Opt. Lett. 37(23), (2012). 21. American National Standard for Safe Use of Lasers ANSI Z136, (American National Standards Institute, Inc., 2007) 22. R. A. Leitgeb, R. Michaely, T. Lasser, and S. C. Sekhar, Complex ambiguity-free Fourier domain optical coherence tomography through transverse scanning, Opt. Lett. 32(23), (2007). 23. R. K. Wang, In vivo full range complex Fourier domain optical coherence tomography, Appl. Phys. Lett. 90(5), (2007). 24. Halina Abramczyk, Dispersion phenomena in optical fibers, Corning SMF-28 Optical Fiber, 1. Introduction Optical coherence tomography (OCT) is a noninvasive and depth-resolved in vivo imaging technique that can image tissue structure with a high axial resolution [1,2]. Unlike conventional time domain OCT (TD-OCT), Fourier domain OCT (FD-OCT) obtains depthresolved information of the tissue through Fourier transform of the detected interference signal. FD-OCT can be generally classified as spectral domain OCT (SD-OCT) and swept source OCT (SS-OCT). FD-OCT images intrinsically contain zero-delay lines and autocorrelation (AC) artifacts. This noise causes image distortion. Balanced detection (BD) has improved the signal-to-noise ratio (SNR) and efficiently removed DC noise and AC artifacts in the OCT configuration using a dual balanced detector such as in the cases of TD- OCT and SS-OCT [3 5]. On the other hand, most existing SD-OCT techniques use the unbalanced detection (UD) method to configure a single spectrometer in the detection arm. The background subtraction is an essential signal procedure to minimize DC noise; however, lower sensitivity and AC noise remain its drawbacks. Recently, several balanced detection SD-OCT (BD-SD-OCT) designs have been proposed. One such proposed SD-OCT system used two different spectrometers. However, this system suffered from alignment issues while acquiring two opposing fringe signals [6,7]. Although the two spectrometers were tightly aligned, the output fringes often contained minor phase errors, which decreased the SNR significantly, especially with increasing optical path difference (OPD) between the sample and reference arms. In addition, for optimal use of the two-spectrometer system, two cameras should have the same quantum efficiency and uncorrected noise during signal acquisition. Furthermore, using two spectrometers makes the system expensive and bulky. Another BD-SD-OCT system used a single-area CCD camera [8]. In the previous study, the spectrometer comprised two input fibers and an area CCD camera to simultaneously measure the two opposing phased fringe spectra. However, this BD method utilized the whole detection area of the CCD camera from which only two spectral lines were selected to balance the interference signals. The unused data-flow made the data acquisition slower and limited the overall A-scan rate to lower than a few frames per second. Optical switches have served various purposes in OCT, such as AC removal, single spectrometer polarization-sensitive OCT (PS-OCT), and simultaneous imaging of an anterior (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23080

3 segment and retina [9 12]. Also, buffering methods using a delay line (DL) have been widely applied in Fourier domain mode locked laser (FDML) sources, system speed improvement, imaging depth enhancements, etc [13 17]. In this work, we propose a novel BD method for SD-OCT with a single line-scan camera. The proposed method applies a 1 2 optical switch and a time delay to achieve balanced interference signal acquisition. Using our method, we successfully removed the phase mismatch between two anti-phase interference signals and enhanced the dynamic range of the OCT system. 2. Methods 2.1 Experimental setup Fig. 1. Schematic of the balanced SD-OCT system using a single camera and a time delay. SLD: superluminescent diode, FC1: 90/10 fiber coupler, FC2: 50/50 fiber coupler, C: circulator, PC1-4: polarization controller, OS: optical switch, DL: delay line, GS: galvano scanner, M: mirror CL: collimation lens, L: lens, NDF: neutral density filter, OL: objective lens. Signal flow in the red box will be explained in Fig. 3. Figure 1 shows the schematic of the proposed system based on a Mach-Zehnder interferometer. A superluminescent diode (SLD, DenseLight Semiconductors Incorporated, Singapore) provides a broadband optical source with a center wavelength of 1310 nm and FWHM spectral width of 150 nm that is split into a reference arm and a sample arm by a /10 fiber coupler (FC1). Reflected light from each arm recombines in a /50 fiber coupler (FC2) to form interference signals. After the signals pass through a second coupler (FC2), the phase difference between the divided signals is naturally π. One of the FC2 output is directly guided to a fast 1 2 optical switch (maximum switching speed of 1 MHz, Boston Applied Technologies, USA) and the other travels along an optical delay line. The optical switch delivers two anti-phase fringes from the 2 2 coupler to the single spectrometer in sequence. BD utilizes two consecutive A-scan signals from adjacent, but different, sample positions, which inevitably creates errors without the DL. The DL prevents this problem. The SD-OCT system consists of a linear-in-wavenumber spectrometer (Bayspec, USA) to improve the sensitivity roll-off. An InGaAs line-scan camera (Goodrich Corporation, USA) in the spectrometer has 2048 pixels, 12-bit resolution, and a maximum line rate of 76 khz. Axial resolution and transverse resolution were measured to be 7.9 μm and 21 μm in air, respectively. A CUDA (computer unified device architecture) and multithread programming allowed for real-time display of OCT images. (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23081

4 2.2 Spectral fringe signal flow with optical switching and time delay Figure 2(a) represents the synchronized signals timing diagram between the camera, the optical switch, and the 2-D galvano-scanner controlled by the DAQ board. BD OCT requires two anti-phase fringe signals from the same sample spot. However, the DAQ analog output signal instability easily affects the interference signals. Even though the same voltage signal drives the galvano-scanner during the acquisition of each of the two anti-phase signals, a small, unexpected OPD change can be introduced, as shown in Fig. 2(b). The OPD change causes a random phase shift between the two interference signals generated at time t 1 and t 2, losing the π phase difference. Balancing with the two mismatched interference signals deteriorates the sensitivity and the visibility of the OCT images. Fig. 2. (a) Timing diagram of synchronization of the camera with the optical switch and the galvano-scanner. (b) Unexpected OPD generation due to unstable DAQ analog output signal during signal acquisition. The galvano-scanner position at times t 1 and t 2 are ideally the same. Figure 3 shows signal flow diagrams following the optical switch redrawn from the red box of Fig. 1 with and without corrective time delay. S and S* refer to mutually opposing spectra collected simultaneously. Figure 3(a) shows the signal flow chart without DL. When channel 1 of the optical switch is on at time t 1, S 1, one of the two spectra formed at time t 1, is transmitted to the spectrometer, but S 1 * is blocked in channel 2, which is switched off. When channel 2 of the optical switch is on at time t 2, S 2 *, which is one of the two spectra collected at time t 2, is transmitted to the spectrometer; however, S 2 is blocked in channel 1, which is switched off. Figure 3(b) shows the signal flow-chart when the DL is introduced. The spectrometer measures the first fringe signal, S 1, at time t 1. The signal S 1 * generated from the same spot as S 1, but with an anti-phase of π due to an intrinsic property of the fiber coupler, travels through the DL. By the time the signal S 1 * reaches the end of the DL, the optical switch has switched channel 2 on. Then, the signal S 1 * is detected. This sequence is repeated for every A-scan. To summarize, the camera sequentially detects different interference signals S 1 and S 2 *, each generated at different times, without the DL. In contrast, the fringe pair, S 1 and S 1 *, is generated at the same scanning position and time, with the DL. The two measured fringe signals have an exact phase difference of π. Thus, the BD calculations introduced in [8] can be easily performed without the expected potential errors shown in Fig. 3(a). (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23082

5 Fig. 3. (a) Propagation of interference signals according to the optical switch with no time delay. (b) Propagation of interference signals according to the optical switch with time delay. (c) A table shows obtained spectra according to BD with and without DL. OS: optical switch, FC: fiber coupler, PC: polarization controller, DL: delay line. S is an interference signal which is one of two spectra separated by FC2. S* is the other passed through DL. In our design, an extra DL that consists of a single mode fiber (SMF) several kilometers in length is incorporated prior to the optical switch to match the anti-phase signals. The modulation frequency of the optical switch is half of the camera line rate and the SMF length is given by: l fiber = c fc n eff. (1) where f c is the camera line rate, c is the speed of light, and n eff is the effective refractive group index of the optical fiber [13]. Throughout this study, OCT images were obtained at a camera line rate of 76 khz, optical switching rate of 38 khz, and camera exposure time of 9.21 μs. The optical fiber delay line was 2.69 km length and the effective refractive group index was 1.43 at 1.3 μm wavelength. 3. Results 3.1 Roll-off with depth for three different detection methods To evaluate our design s performance, we compared each acquired image with an image acquired by the conventional SD-OCT with UD scheme. All images obtained by UD was acquired after background subtraction to eliminate the reference (DC) power. Spectrally BD optimally compensated for the difference in overall signal levels caused by a non-uniform coupling ratio of the 3 db fiber coupler and insertion loss of the DL [18]. It is important to match the spectral envelope of the interference signals to reduce DC term. Spectrally BD also eliminates undesirable fixed pattern noise due to light source fluctuations over time. (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23083

6 Fig. 4. Interference fringes from the 250th A line of 500 A lines detected by our BD-SD-OCT (a) without the DL (b) with the DL, (c) black: balanced signals subtracted black signal from red signal of (b), red: balanced signals subtracted black signal from red signal of (a), (d) point spread function of (c). The sensitivity improved about 4.79 db after applying the DL. Figure 4 shows the interference fringes obtained by the BD-SD-OCT with and without the DL. A slightly tilted mirror was placed at the sample arm and laterally scanned. The phase shift without DL is not clear, as shown in Fig. 4(a), whereas the two fringe spectra with DL exhibit almost an exact π phase shift in Fig. 4(b). Figure 4(c) shows the balanced signals from Figs. 4(a) and 4(b) before and after correcting phase error using DL. The resulting difference fringe amplitudes are displayed in red and black in Fig. 4(c), respectively. As expected, the fringe amplitude is larger when DL is used. The sensitivity of the BD-SD-OCT system can be quantified after inverse Fast Fourier Transform (FFT) of the balanced signal, presented in Fig. 4(d). To measure the sensitivity of the system, 11.2 db and 5.3 db neutral density filters were placed in the sample and the reference arm (round trip 33 db attenuation), respectively, and a 5 db coupling loss occurred by tilting the sample mirror. The measured sensitivities of the BD without and with the DL were db and db at 200 μm, respectively. Therefore, the sensitivity improved by approximately 4.79 db with the DL. The difference depends on the tilt angle of the mirror at the sample arm and the A-scan interval. When compensating for systematic attenuation, the peak sensitivity reaches db with DL. Figure 5 shows the signal sensitivity fall-off as a function of depth. We measured the sensitivity of our SD-OCT system for three different cases: UD, BD without DL, and BD with DL. The effective imaging range for a 10 db sensitivity drop was 3 mm for all cases. Throughout the depth range, the sensitivity difference between the BD-SD-OCT with DL and the UD OCT is 6 db. The 6 db sensitivity enhancement over the whole imaging range agrees with theoretical prediction. This implies that the π phase difference between the two spectra is maintained accurately, regardless of the OCT imaging depth. (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23084

7 Fig. 5. The measured sensitivity roll-off as a function of depth. Red line and square points refer to the sensitivity of BD-SD-OCT with DL. Blue line and circle points refer to the sensitivity of BD-SD-OCT without DL. Black line and triangle points refer to the sensitivity of UD. The sensitivity enhancement between the BD-SD-OCT with DL and the UD-OCT is about 6 db. 3.2 A multilayer tape imaging 2D OCT images of a rolled tape are shown in Fig. 6. As before, an image for UD, BD without DL, and BD with DL are presented in Figs. 6(a)-6(c). The scan range of these 2D OCT images was set to 10 mm. As described earlier, the DC noise, shown in Fig. 6(a), was reduced by background subtraction. In addition, AC noise was minimized by increasing the reference power. BD naturally reduces DC noise. A noticeable change after applying BD method is the enhanced visible depth and overall sensitivity. As shown in Fig. 6(c), when BD was employed, the deeper region of the tape was more clearly visualized. It is obvious that imaging depth and brightness are improved in the BD. Comparing Fig. 6(b) and Fig. 6(c), we can see that the signal level of the tape image obtained by BD with the DL is higher than that of an image obtained by BD without the DL. To represent this in more detail, we extracted three A-scans for each of the red dotted lines in Figs. 6(b) and 6(c), and averaged them. The depth-resolved signals through FFT of the averaged A-line data are shown in Fig. 6(d). Figure 6(e) is the depth-resolved signal with a low pass filter. The boundary between air and the sample surface was located 0.8 mm from DC line. We found the mean intensity values of air and the sample regions before and after applying the DL. The mean value at the air region almost coincides with the noise level of the system. The mean noise levels in BD with and without the DL are 20.1 db and db, respectively, marked by dotted lines in Fig. 6(e). It shows that noise in BD with the DL is lower than that in BD without the DL. On the other hand, the mean values of the sample signals detected by the BD method with and without the DL are 7.7 db and 10.2 db, respectively. The sample signal detected by BD with the DL is approximately 2.75 db higher than that detected by BD without the DL. (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23085

8 Fig. 6. 2D OCT images of a multilayer tape obtained by UD, (a) BD without the DL, and (b) BD with the DL (c), (d) depth-resolved A-line signals through FFT of averaged red lines in Figs. 6(b) and 6(c), (e) depth-resolved A-line signals with a low-pass filter, red dotted line: mean noise level in BD with DL, black dotted line: mean noise level in BD without DL. 3.3 In vivo imaging of rat-tail and human eye Figure 7 shows in vivo rat-tail OCT images obtained by the three detection methods as in the previous experiment. Each image consists of 350 (axial) 500 (lateral) pixels and has a scan range of 10 mm. Comparing the three images, we see that the results are quite similar to those obtained in the previous multilayer tape experiment. We can easily observe that the image contrast of Fig. 7(c) is higher than that of other images, Figs. 7(a) and 7(b). Besides, the visible depth range is also extended owing to an increase in sensitivity. # (C) 2015 OSA Received 2 Jun 2015; revised 11 Jul 2015; accepted 22 Jul 2015; published 25 Aug Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23086

9 Fig. 7. Rat-tail OCT images obtained by (a) UD, (b) BD without the DL, and (c) BD with the DL. Red dotted lines (1), (2), and (3) in Fig. 7 will be discussed in Fig. 8. Intensity profiles of the three red dotted line marked on Figs. 7(a)-7(c) are shown in Figs. 8(a)-8(c). Each A-line was extracted for the three detection cases and was constructed by taking average of 7 adjacent A-scans. The A-line was normalized after low pass filtering. Observing the change in intensity obtained by BD without the DL, we see that the intensity profile of BD with the DL exhibits an intensity profile similar to the UD case in Fig. 8(a). Figure 8(b) shows that the intensity of BD without the DL lies somewhere in the middle of UD and BD with the DL in depth of the sample. In contrast to Fig. 8(a), the intensity of BD without the DL is analogous to the intensity of BD with the DL. We calculated the normalized intensity mean values in the range between 0.3 mm and 1.4 mm (inside region of the tissue) for the three detection methods as shown in Fig. 8(d). Normalized intensity mean values of BD with the DL are constantly about 1.6 times higher than that of UD for the three A-scan locations shown in Fig. 7. On the other hand, the intensity mean values obtained by BD without the DL are changed randomly, depending on the later position of the tissue. It should be noted that if the phase difference between adjacent A-lines is ambiguous due to the highscattering tissue, then the proposed system does not detect phase difference accurately, without the DL. If the proposed BD-SD-OCT system is implemented without the DL, the sensitivity will vary according to the A-scan position. (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23087

10 Fig. 8. (a)-(c) Normalized intensity profiles after averaging each of the 7 A-lines marked by red dotted lines, (1), (2), and (3), in Fig. 7, (d) Intensity mean values obtained from each normalized intensity signal in the range between 0.3 mm and 1.4 mm in Fig. 8(a)-8(c). We performed an in vivo experiment on a human eye using our BD-SD-OCT system combined with the off-pivot scanning method for a full range complex imaging [19,20]. The resolution of the spectrometer was nm and a maximum ranging depth of the UD OCT was limited by 5.9 mm. The depth range for full range imaging was extended to 11.8 mm. We imaged an anterior segment of a human volunteer s eye, as shown in Fig. 9. The incident light power on the eye was measured to be 10 mw, which satisfies ANSI safety standards [21]. The off-pivot scanning method requires a large number of A-lines, at least more than 1000, for efficient removal of mirror artifacts [22,23]. The 2D eye OCT images consisted of 2048 (axial) 2500 (lateral) pixels. Images taken with UD, BD without DL, and BD with DL SD- OCT are presented in Figs. 9(a)-9(c), respectively. Three normalized intensity profiles of each yellow dotted line in Figs. 9(a)-9(c) (10 adjacent A-lines were averaged) was shown in Figs. 9(d)-(f). Red dotted lines in Figs. 9(d)-9(f) were obtained after low pass filtering. As shown in A-line profile of UD in Fig. 9(d), the signal level of the cornea was very close to the noise level, so it is hard to differentiate between sample signals and noise. However, Figs. 9(e) and 9(f) showed that the cornea was easily distinguished through BD. In Figs. 9(d)-9(f), the signal levels of red lines at the lens surface were 0.4 (UD), 0.58 (BD without DL), and 0.7 (BD with DL), respectively. Signals from the human eye was the highest in BD with DL. The difference of signal level between BD with and without DL could have been more pronounced if a smaller interval had been used between two adjacent A-scans. If the interval is smaller, the two consecutive A-line data used for BD will be almost identical, thus, the phase error becomes minimal. In this experiment, the signal level at the lens surface of BD with DL was only 1.2 times than that of BD without DL due to the use of 2500 A-scans. DL greatly (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23088

11 reduced speckle noise, as seen in comparisons of Figs. 9(b) and 9(c). In Figs. 9(d)-9(f), Mean noise levels from 512 axial pixels to 1010 axial pixels in the anterior chamber region were 0.1 (UD), 0.18 (BD without DL), and 0.09 (BD with DL), respectively. Noise level of BD without DL was about twofold than that of BD with DL and it was also higher than that of UD after background subtraction. Fig. 9. left column: In vivo imaging of a human volunteer s eye using BD-SD-OCT. (a) human eye image using UD, (b) BD without DL, and (c) BD with DL, right column: intensity profiles of yellow dotted lines marked on images in left column. (d) A normalized intensity profile of the yellow line in Fig. 9(a), (e) A normalized intensity profile of the yellow line in Fig. 9(b), (f) A normalized intensity profile of the yellow line in Fig. 9(c). LPF: low pass filter. Note that DC line in image was not removed and no filter processing was employed. # (C) 2015 OSA Received 2 Jun 2015; revised 11 Jul 2015; accepted 22 Jul 2015; published 25 Aug Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23089

12 4. Discussions and conclusion BD in OCT requires two signals with exactly opposite phases from a single A-scan location to effectively remove undesirable noise, improving SNR. Since SD-OCT, unlike SS-OCT, uses a spectrometer as a detector, BD cannot be easily implemented. As was demonstrated, SD-OCT with BD can be achieved using a single line-scan camera and an optical switch, but such quick consecutive scanning creates slight variations in the A-scan positions of the two fringe signals with opposite phases. To solve this problem, a simple fiber optic DL is used. An advantage of using the DL becomes pronounced when dealing with imaging samples with rough surfaces (see Figs. 7 and 9). If the DL is omitted, the two consecutive A-scan signals, which may not originate from the exact same spot, are combined to generate a balanced signal. Sharper surface morphology changes create larger phase ambiguities in the balanced signal. This effect becomes more significant when a smaller number of A-lines are used to generate the same sized 2D image. Increasing the number of A-lines from 500 to 2000 in BD-SD-OCT negates the effect of the DL (data not shown). This suggests that, especially with a smaller number of A-lines, the image quality could be much improved using our system. Comparing the proposed BD method with UD applied off-pivot full range technique, imaging depth of UD with off-pivot technique is doubled, but the sensitivity of the system remains unchanged. In addition, as a large number of A-scans will be required to eliminate mirror artifacts effectively, the speed of the system decreases accordingly. In contrast, the imaging depth of BD with DL is enlarged as the sensitivity of the system is improved, without increasing the number of A-scans. One shortcoming of our design is the image acquisition speed, which was reduced by half, since we measured two times at the same sample position using an optical switch for BD. Careful observation of Fig. 9 reveals that a simple background subtraction produces lesser speckle noise than the BD-SD-OCT without the DL. However, considering the fact that background noise can vary with time, the BD-SD-OCT still produces more stable images. It is clear that the BD-SD-OCT with the DL produces minimal speckle noise. In this study, a very long SMF bundle acted as the DL. The wavelength range of the SD- OCT system spanned from 1235 nm to 1385 nm. The theoretical dispersion coefficient (D(λ)) in the fiber is approximately ps/(km nm) at 1237 nm and ps/(km nm) at 1384 nm [24, 25]. The estimated group delay is about 36 ps, after passing through the 2.69 km DL. The camera exposure time (9.21 μsec) is much larger than this group delay, therefore, we can ignore the dispersion effect caused by the long DL. Additionally, polarization mode dispersion (PMD) of the optical switch and the delay line are less than 0.1 ps and 0.3 ps, respectively. There values are much shorter than the camera speed, so it is negligible as the dispersion. To summarize, we have demonstrated a new SD-OCT design for BD that has clear advantages over previously reported systems. An ultrafast optical switch and a time delay line were added in order to accurately detect interference fringes with opposite phases using a single camera. In comparison with conventional SD-OCT, the sensitivity was improved by more than 6 db, which improved image quality by eliminating AC and DC noise. Acknowledgments This study was supported by a grant of the Korean Health Technology R&D Project, Ministry of Health & Welfare, Republic of Korea (HI13C1501), the Original Technology Research Program for Brain Science through the National Research Foundation of Korea (NRF) funded by the Ministry of Science ICT and Future Planning (NRF-2015M3C7A ), the new growth power equipment competitiveness reinforcement program ( ), the Industrial Strategic Technology Development Program ( ) funded by the Ministry of Trade, industry & Energy, and the APRI Research Program through a grant provided by the (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23090

13 Gwangju Institute of Science and Technology in All correspondence to Beop-Min Kim, Tae Joong Eom, (C) 2015 OSA 7 Sep 2015 Vol. 23, No. 18 DOI: /OE OPTICS EXPRESS 23091

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography 60 MHz Aline rate ultrahigh speed Fourierdomain optical coherence tomography K. Ohbayashi a,b), D. Choi b), H. HiroOka b), H. Furukawa b), R. Yoshimura b), M. Nakanishi c), and K. Shimizu c) a Graduate

More information

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism VI Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism Fang-Wen Sheu and Pei-Ling Luo Department of Applied Physics, National Chiayi University, Chiayi

More information

some aspects of Optical Coherence Tomography

some aspects of Optical Coherence Tomography some aspects of Optical Coherence Tomography SSOM Lectures, Engelberg 17.3.2009 Ch. Meier 1 / 34 Contents 1. OCT - basic principles (Time Domain Frequency Domain) 2. Performance and limiting factors 3.

More information

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography 3. The Art of OCT Dr. Gereon Hüttmann / 2009 System perspective (links clickable) Light sources Superluminescent diodes

More information

High-speed imaging of human retina in vivo with swept-source optical coherence tomography

High-speed imaging of human retina in vivo with swept-source optical coherence tomography High-speed imaging of human retina in vivo with swept-source optical coherence tomography H. Lim, M. Mujat, C. Kerbage, E. C. W. Lee, and Y. Chen Harvard Medical School and Wellman Center for Photomedicine,

More information

Short Ring Cavity Swept Source Based on a Highly Reflective Chirped FBG

Short Ring Cavity Swept Source Based on a Highly Reflective Chirped FBG PHOTONIC SENSORS / Vol. 5, No. 3, 215: 251 256 Short Ring Cavity Swept Source Based on a Highly Reflective Chirped FBG Radu-Florin STANCU * and Adrian PODOLEANU Applied Optics Group, School of Physical

More information

High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength

High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength S. H. Yun, G. J. Tearney, B. E. Bouma, B. H. Park, and J. F. de Boer Harvard Medical School and Wellman Center of Photomedicine,

More information

Off-axis full-field swept-source optical coherence tomography using holographic refocusing

Off-axis full-field swept-source optical coherence tomography using holographic refocusing Off-axis full-field swept-source optical coherence tomography using holographic refocusing Dierck Hillmann *,a, Gesa Franke b,c, Laura Hinkel b, Tim Bonin b, Peter Koch a, Gereon Hüttmann b,c a Thorlabs

More information

Frequency comb swept lasers

Frequency comb swept lasers Frequency comb swept lasers Tsung-Han Tsai 1, Chao Zhou 1, Desmond C. Adler 1, and James G. Fujimoto 1* 1 Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics,

More information

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Abstract: Speckle interferometry (SI) has become a complete technique over the past couple of years and is widely used in many branches of

More information

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As

More information

Differential measurement scheme for Brillouin Optical Correlation Domain Analysis

Differential measurement scheme for Brillouin Optical Correlation Domain Analysis Differential measurement scheme for Brillouin Optical Correlation Domain Analysis Ji Ho Jeong, 1,2 Kwanil Lee, 1,4 Kwang Yong Song, 3,* Je-Myung Jeong, 2 and Sang Bae Lee 1 1 Center for Opto-Electronic

More information

Optimization for Axial Resolution, Depth Range, and Sensitivity of Spectral Domain Optical Coherence Tomography at 1.3 µm

Optimization for Axial Resolution, Depth Range, and Sensitivity of Spectral Domain Optical Coherence Tomography at 1.3 µm Journal of the Korean Physical Society, Vol. 55, No. 6, December 2009, pp. 2354 2360 Optimization for Axial Resolution, Depth Range, and Sensitivity of Spectral Domain Optical Coherence Tomography at 1.3

More information

Frequency comb swept lasers for optical coherence tomography

Frequency comb swept lasers for optical coherence tomography Frequency comb swept lasers for optical coherence tomography The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As Published

More information

Optical coherence tomography

Optical coherence tomography Optical coherence tomography Peter E. Andersen Optics and Plasma Research Department Risø National Laboratory E-mail peter.andersen@risoe.dk Outline Part I: Introduction to optical coherence tomography

More information

Citation for published version (APA): Nguyen, D. V. (2013). Integrated-optics-based optical coherence tomography

Citation for published version (APA): Nguyen, D. V. (2013). Integrated-optics-based optical coherence tomography UvA-DARE (Digital Academic Repository) Integrated-optics-based optical coherence tomography Nguyen, Duc Link to publication Citation for published version (APA): Nguyen, D. V. (2013). Integrated-optics-based

More information

Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique

Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique Jeff Fingler 1,*, Robert J. Zawadzki 2, John S. Werner 2, Dan Schwartz 3, Scott

More information

Supplementary Figures

Supplementary Figures Supplementary Figures Supplementary Figure 1: Mach-Zehnder interferometer (MZI) phase stabilization. (a) DC output of the MZI with and without phase stabilization. (b) Performance of MZI stabilization

More information

A WDM passive optical network enabling multicasting with color-free ONUs

A WDM passive optical network enabling multicasting with color-free ONUs A WDM passive optical network enabling multicasting with color-free ONUs Yue Tian, Qingjiang Chang, and Yikai Su * State Key Laboratory of Advanced Optical Communication Systems and Networks, Department

More information

A NOVEL SCHEME FOR OPTICAL MILLIMETER WAVE GENERATION USING MZM

A NOVEL SCHEME FOR OPTICAL MILLIMETER WAVE GENERATION USING MZM A NOVEL SCHEME FOR OPTICAL MILLIMETER WAVE GENERATION USING MZM Poomari S. and Arvind Chakrapani Department of Electronics and Communication Engineering, Karpagam College of Engineering, Coimbatore, Tamil

More information

Frequency comb swept lasers

Frequency comb swept lasers Frequency comb swept lasers The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As Published Publisher Tsai, Tsung-Han et al.

More information

GRENOUILLE.

GRENOUILLE. GRENOUILLE Measuring ultrashort laser pulses the shortest events ever created has always been a challenge. For many years, it was possible to create ultrashort pulses, but not to measure them. Techniques

More information

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology Dejiao Lin, Xiangqian Jiang and Fang Xie Centre for Precision Technologies,

More information

Laser Sources for Frequency-Domain Optical Coherence Tomography FD-OCT

Laser Sources for Frequency-Domain Optical Coherence Tomography FD-OCT Laser Sources for Frequency-Domain Optical Coherence Tomography FD-OCT Photonic Sensing Workshop SWISSLaser.Net Biel, 17. 9. 2009 Ch. Meier 1/ 20 SWISSLASER.NET Ch. Meier 17.09.09 Content 1. duction 2.

More information

All-Optical Signal Processing and Optical Regeneration

All-Optical Signal Processing and Optical Regeneration 1/36 All-Optical Signal Processing and Optical Regeneration Govind P. Agrawal Institute of Optics University of Rochester Rochester, NY 14627 c 2007 G. P. Agrawal Outline Introduction Major Nonlinear Effects

More information

Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise

Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise Ben Wu, * Zhenxing Wang, Bhavin J. Shastri, Matthew P. Chang, Nicholas A. Frost, and Paul R. Prucnal

More information

All optical wavelength converter based on fiber cross-phase modulation and fiber Bragg grating

All optical wavelength converter based on fiber cross-phase modulation and fiber Bragg grating All optical wavelength converter based on fiber cross-phase modulation and fiber Bragg grating Pavel Honzatko a, a Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, v.v.i.,

More information

Multi-format all-optical-3r-regeneration technology

Multi-format all-optical-3r-regeneration technology Multi-format all-optical-3r-regeneration technology Masatoshi Kagawa Hitoshi Murai Amount of information flowing through the Internet is growing by about 40% per year. In Japan, the monthly average has

More information

Optical Coherence Tomography Systems and signal processing in SD-OCT

Optical Coherence Tomography Systems and signal processing in SD-OCT Optical Coherence Tomography Systems and signal processing in SD-OCT Chandan S.Rawat 1, Vishal S.Gaikwad 2 1 Associate Professor V.E.S.I.T., Mumbai chandansrawat@gmail.com 2 P.G.Student, V.E.S.I.T., Mumbai

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Realization of 16-channel digital PGC demodulator for fiber laser sensor array

Realization of 16-channel digital PGC demodulator for fiber laser sensor array Journal of Physics: Conference Series Realization of 16-channel digital PGC demodulator for fiber laser sensor array To cite this article: Lin Wang et al 2011 J. Phys.: Conf. Ser. 276 012134 View the article

More information

Optimisation of DSF and SOA based Phase Conjugators. by Incorporating Noise-Suppressing Fibre Gratings

Optimisation of DSF and SOA based Phase Conjugators. by Incorporating Noise-Suppressing Fibre Gratings Optimisation of DSF and SOA based Phase Conjugators by Incorporating Noise-Suppressing Fibre Gratings Paper no: 1471 S. Y. Set, H. Geiger, R. I. Laming, M. J. Cole and L. Reekie Optoelectronics Research

More information

Transmission- and side-detection configurations in ultrasound-modulated optical tomography of thick biological tissues

Transmission- and side-detection configurations in ultrasound-modulated optical tomography of thick biological tissues Transmission- and side-detection configurations in ultrasound-modulated optical tomography of thick biological tissues Jun Li, Sava Sakadžić, Geng Ku, and Lihong V. Wang Ultrasound-modulated optical tomography

More information

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade: Examination Optoelectronic Communication Technology April, 26 Name: Student ID number: OCT : OCT 2: OCT 3: OCT 4: Total: Grade: Declaration of Consent I hereby agree to have my exam results published on

More information

Simultaneous multiple-depths en-face optical coherence tomography using multiple signal excitation of acousto-optic deflectors

Simultaneous multiple-depths en-face optical coherence tomography using multiple signal excitation of acousto-optic deflectors Simultaneous multiple-depths en-face optical coherence tomography using multiple signal excitation of acousto-optic deflectors Mantas Zurauskas, * John Rogers, and Adrian Gh. Podoleanu Applied Optics Group,

More information

Chirped Bragg Grating Dispersion Compensation in Dense Wavelength Division Multiplexing Optical Long-Haul Networks

Chirped Bragg Grating Dispersion Compensation in Dense Wavelength Division Multiplexing Optical Long-Haul Networks 363 Chirped Bragg Grating Dispersion Compensation in Dense Wavelength Division Multiplexing Optical Long-Haul Networks CHAOUI Fahd 3, HAJAJI Anas 1, AGHZOUT Otman 2,4, CHAKKOUR Mounia 3, EL YAKHLOUFI Mounir

More information

High-Coherence Wavelength Swept Light Source

High-Coherence Wavelength Swept Light Source Kenichi Nakamura, Masaru Koshihara, Takanori Saitoh, Koji Kawakita [Summary] Optical technologies that have so far been restricted to the field of optical communications are now starting to be applied

More information

Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm

Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm Jan Philip Kolb 1,2, Thomas Klein 2,3, Mattias Eibl 1,2, Tom Pfeiffer 1,2, Wolfgang Wieser 2,3 and Robert Huber

More information

Soliton stability conditions in actively modelocked inhomogeneously broadened lasers

Soliton stability conditions in actively modelocked inhomogeneously broadened lasers Lu et al. Vol. 20, No. 7/July 2003 / J. Opt. Soc. Am. B 1473 Soliton stability conditions in actively modelocked inhomogeneously broadened lasers Wei Lu,* Li Yan, and Curtis R. Menyuk Department of Computer

More information

Phase-Sensitive Optical Time-Domain Reflectometry Amplified by Gated Raman Pump

Phase-Sensitive Optical Time-Domain Reflectometry Amplified by Gated Raman Pump PHOTONIC SENSORS / Vol. 5, No. 4, 2015: 345 350 Phase-Sensitive Optical Time-Domain Reflectometry Amplified by Gated Raman Pump Yi LI *, Yi ZHOU, Li ZHANG, Mengqiu FAN, and Jin LI Key Laboratory of Optical

More information

Customized Lasers for Specific Swept Source OCT Applications. Bill Ahern Axsun Technologies, Inc. June 20, 2013

Customized Lasers for Specific Swept Source OCT Applications. Bill Ahern Axsun Technologies, Inc. June 20, 2013 Customized Lasers for Specific Swept Source OCT Applications Bill Ahern Axsun Technologies, Inc. June 20, 2013 Outline Axsun Overview Axsun Technology and Manufacturing Axsun OCT Laser Platform Laser Operation

More information

High-speed optical frequency-domain imaging

High-speed optical frequency-domain imaging High-speed optical frequency-domain imaging S. H. Yun, G. J. Tearney, J. F. de Boer, N. Iftimia and B. E. Bouma Harvard Medical School and Wellman Laboratories for Photomedicine, Massachusetts General

More information

Photonics and Optical Communication

Photonics and Optical Communication Photonics and Optical Communication (Course Number 300352) Spring 2007 Dr. Dietmar Knipp Assistant Professor of Electrical Engineering http://www.faculty.iu-bremen.de/dknipp/ 1 Photonics and Optical Communication

More information

Lecture 8 Fiber Optical Communication Lecture 8, Slide 1

Lecture 8 Fiber Optical Communication Lecture 8, Slide 1 Lecture 8 Bit error rate The Q value Receiver sensitivity Sensitivity degradation Extinction ratio RIN Timing jitter Chirp Forward error correction Fiber Optical Communication Lecture 8, Slide Bit error

More information

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration 22 Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration Jun-Hyuk Seo, and Woo-Young Choi Department of Electrical and

More information

Vixar High Power Array Technology

Vixar High Power Array Technology Vixar High Power Array Technology I. Introduction VCSELs arrays emitting power ranging from 50mW to 10W have emerged as an important technology for applications within the consumer, industrial, automotive

More information

Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection

Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection Adnan H. Ali Technical college / Baghdad- Iraq Tel: 96-4-770-794-8995 E-mail: Adnan_h_ali@yahoo.com Received: April

More information

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024 Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 1 Suwanee, GA 324 ABSTRACT Conventional antenna measurement systems use a multiplexer or

More information

Multi-wavelength laser generation with Bismuthbased Erbium-doped fiber

Multi-wavelength laser generation with Bismuthbased Erbium-doped fiber Multi-wavelength laser generation with Bismuthbased Erbium-doped fiber H. Ahmad 1, S. Shahi 1 and S. W. Harun 1,2* 1 Photonics Research Center, University of Malaya, 50603 Kuala Lumpur, Malaysia 2 Department

More information

Low-noise broadband light generation from optical fibers for use in high-resolution optical coherence tomography

Low-noise broadband light generation from optical fibers for use in high-resolution optical coherence tomography 1492 J. Opt. Soc. Am. A/ Vol. 22, No. 8/ August 2005 Wang et al. Low-noise broadband light generation from optical fibers for use in high-resolution optical coherence tomography Yimin Wang, Ivan Tomov,

More information

Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second

Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second Wolfgang Wieser, Benjamin R. Biedermann, Thomas Klein, Christoph M. Eigenwillig and Robert Huber* Lehrstuhl

More information

Swept Wavelength Testing:

Swept Wavelength Testing: Application Note 13 Swept Wavelength Testing: Characterizing the Tuning Linearity of Tunable Laser Sources In a swept-wavelength measurement system, the wavelength of a tunable laser source (TLS) is swept

More information

Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography

Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography Barry Cense, Nader A. Nassif Harvard Medical School and Wellman Center for Photomedicine, Massachusetts

More information

Interference [Hecht Ch. 9]

Interference [Hecht Ch. 9] Interference [Hecht Ch. 9] Note: Read Ch. 3 & 7 E&M Waves and Superposition of Waves and Meet with TAs and/or Dr. Lai if necessary. General Consideration 1 2 Amplitude Splitting Interferometers If a lightwave

More information

Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides

Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides Yaming Li, Chong Li, Chuanbo Li, Buwen Cheng, * and Chunlai Xue State Key Laboratory on Integrated Optoelectronics,

More information

Swept Source Optical Coherence Tomography for Small Animals: System Control and Data Acquisition

Swept Source Optical Coherence Tomography for Small Animals: System Control and Data Acquisition University of Coimbra Faculty of Sciences and Technology Department of Physics Swept Source Optical Coherence Tomography for Small Animals: System Control and Data Acquisition Master s Degree in Physics

More information

Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer

Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer Michael North Morris, James Millerd, Neal Brock, John Hayes and *Babak Saif 4D Technology Corporation, 3280 E. Hemisphere Loop Suite 146,

More information

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor Development of a Low Cost 3x3 Coupler Mach-Zehnder Interferometric Optical Fibre Vibration Sensor Kai Tai Wan Department of Mechanical, Aerospace and Civil Engineering, Brunel University London, UB8 3PH,

More information

Performance Evaluation using M-QAM Modulated Optical OFDM Signals

Performance Evaluation using M-QAM Modulated Optical OFDM Signals Proc. of Int. Conf. on Recent Trends in Information, Telecommunication and Computing, ITC Performance Evaluation using M-QAM Modulated Optical OFDM Signals Harsimran Jit Kaur 1 and Dr.M. L. Singh 2 1 Chitkara

More information

White-light interferometry, Hilbert transform, and noise

White-light interferometry, Hilbert transform, and noise White-light interferometry, Hilbert transform, and noise Pavel Pavlíček *a, Václav Michálek a a Institute of Physics of Academy of Science of the Czech Republic, Joint Laboratory of Optics, 17. listopadu

More information

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

SUPPLEMENTARY INFORMATION DOI: /NPHOTON Supplementary Methods and Data 1. Apparatus Design The time-of-flight measurement apparatus built in this study is shown in Supplementary Figure 1. An erbium-doped femtosecond fibre oscillator (C-Fiber,

More information

Stability of a Fiber-Fed Heterodyne Interferometer

Stability of a Fiber-Fed Heterodyne Interferometer Stability of a Fiber-Fed Heterodyne Interferometer Christoph Weichert, Jens Flügge, Paul Köchert, Rainer Köning, Physikalisch Technische Bundesanstalt, Braunschweig, Germany; Rainer Tutsch, Technische

More information

arxiv:physics/ v1 [physics.optics] 12 May 2006

arxiv:physics/ v1 [physics.optics] 12 May 2006 Quantitative and Qualitative Study of Gaussian Beam Visualization Techniques J. Magnes, D. Odera, J. Hartke, M. Fountain, L. Florence, and V. Davis Department of Physics, U.S. Military Academy, West Point,

More information

Kent Academic Repository

Kent Academic Repository Kent Academic Repository Full text document (pdf) Citation for published version Toadere, Florin and Stancu, Radu.-F. and Poon, Wallace and Schultz, David and Podoleanu, Adrian G.H. (2017) 1 MHz Akinetic

More information

Directly Chirped Laser Source for Chirped Pulse Amplification

Directly Chirped Laser Source for Chirped Pulse Amplification Directly Chirped Laser Source for Chirped Pulse Amplification Input pulse (single frequency) AWG RF amp Output pulse (chirped) Phase modulator Normalized spectral intensity (db) 64 65 66 67 68 69 1052.4

More information

Performance Analysis of SOA-MZI based All-Optical AND & XOR Gate

Performance Analysis of SOA-MZI based All-Optical AND & XOR Gate International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Utkarsh

More information

Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts

Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts S. H. Yun, G. J. Tearney, J. F. de Boer, and B. E. Bouma Harvard Medical School and Wellman Center

More information

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 35. Self-Phase-Modulation

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 35. Self-Phase-Modulation FIBER OPTICS Prof. R.K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay Lecture: 35 Self-Phase-Modulation (SPM) Fiber Optics, Prof. R.K. Shevgaonkar, Dept. of Electrical

More information

Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control

Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control S. Witte 1,4, M. Baclayon 1,4, E. J. G. Peterman 1,4, R. F. G. Toonen 2,4, H. D. Mansvelder 3,4, and M.

More information

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers ContourGT with AcuityXR TM capability White light interferometry is firmly established

More information

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION Revised November 15, 2017 INTRODUCTION The simplest and most commonly described examples of diffraction and interference from two-dimensional apertures

More information

Superfast phase-shifting method for 3-D shape measurement

Superfast phase-shifting method for 3-D shape measurement Superfast phase-shifting method for 3-D shape measurement Song Zhang 1,, Daniel Van Der Weide 2, and James Oliver 1 1 Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA 2

More information

Extended coherence length megahertz FDML and its application for anterior segment imaging

Extended coherence length megahertz FDML and its application for anterior segment imaging Extended coherence length megahertz FDML and its application for anterior segment imaging Wolfgang Wieser, 1 Thomas Klein, 1 Desmond C. Adler, 2 Francois Trépanier, 3 Christoph M. Eigenwillig, 1 Sebastian

More information

CHAPTER 4 RESULTS. 4.1 Introduction

CHAPTER 4 RESULTS. 4.1 Introduction CHAPTER 4 RESULTS 4.1 Introduction In this chapter focus are given more on WDM system. The results which are obtained mainly from the simulation work are presented. In simulation analysis, the study will

More information

Communication using Synchronization of Chaos in Semiconductor Lasers with optoelectronic feedback

Communication using Synchronization of Chaos in Semiconductor Lasers with optoelectronic feedback Communication using Synchronization of Chaos in Semiconductor Lasers with optoelectronic feedback S. Tang, L. Illing, J. M. Liu, H. D. I. barbanel and M. B. Kennel Department of Electrical Engineering,

More information

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT Could OCT be a Game Maker OCT in Optometric Practice: A Hands On Guide Murray Fingeret, OD Nick Rumney, MSCOptom Fourier Domain (Spectral) OCT New imaging method greatly improves resolution and speed of

More information

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and EXERCISES OF OPTICAL MEASUREMENTS BY ENRICO RANDONE AND CESARE SVELTO EXERCISE 1 A CW laser radiation (λ=2.1 µm) is delivered to a Fabry-Pérot interferometer made of 2 identical plane and parallel mirrors

More information

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG Optics and Photonics Journal, 2013, 3, 163-168 http://dx.doi.org/10.4236/opj.2013.32027 Published Online June 2013 (http://www.scirp.org/journal/opj) Performance Analysis of WDM RoF-EPON Link with and

More information

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

Timing Noise Measurement of High-Repetition-Rate Optical Pulses 564 Timing Noise Measurement of High-Repetition-Rate Optical Pulses Hidemi Tsuchida National Institute of Advanced Industrial Science and Technology 1-1-1 Umezono, Tsukuba, 305-8568 JAPAN Tel: 81-29-861-5342;

More information

Recent Progress in Pulsed Optical Synchronization Systems

Recent Progress in Pulsed Optical Synchronization Systems FLS 2010 Workshop March 4 th, 2010 Recent Progress in Pulsed Optical Synchronization Systems Franz X. Kärtner Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics,

More information

RECENTLY, studies have begun that are designed to meet

RECENTLY, studies have begun that are designed to meet 838 IEEE JOURNAL OF QUANTUM ELECTRONICS, VOL. 43, NO. 9, SEPTEMBER 2007 Design of a Fiber Bragg Grating External Cavity Diode Laser to Realize Mode-Hop Isolation Toshiya Sato Abstract Recently, a unique

More information

How to build an Er:fiber femtosecond laser

How to build an Er:fiber femtosecond laser How to build an Er:fiber femtosecond laser Daniele Brida 17.02.2016 Konstanz Ultrafast laser Time domain : pulse train Frequency domain: comb 3 26.03.2016 Frequency comb laser Time domain : pulse train

More information

Photomixing THz Spectrometer Review

Photomixing THz Spectrometer Review Photomixing THz Spectrometer Review Joseph R. Demers, PhD 9/29/2015 Leveraging Telecom Manufacturing Techniques to Improve THz Technology Terahertz Spectrum THz radiation was difficult to produce and detect

More information

TCSPC at Wavelengths from 900 nm to 1700 nm

TCSPC at Wavelengths from 900 nm to 1700 nm TCSPC at Wavelengths from 900 nm to 1700 nm We describe picosecond time-resolved optical signal recording in the spectral range from 900 nm to 1700 nm. The system consists of an id Quantique id220 InGaAs

More information

Numerical simulation of a gradient-index fibre probe and its properties of light propagation

Numerical simulation of a gradient-index fibre probe and its properties of light propagation Numerical simulation of a gradient-index fibre probe and its properties of light propagation Wang Chi( ) a), Mao You-Xin( ) b), Tang Zhi( ) a), Fang Chen( ) a), Yu Ying-Jie( ) a), and Qi Bo( ) c) a) Department

More information

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications Carlos Macià-Sanahuja and Horacio Lamela-Rivera Optoelectronics and Laser Technology group, Universidad

More information

Photonics and Optical Communication Spring 2005

Photonics and Optical Communication Spring 2005 Photonics and Optical Communication Spring 2005 Final Exam Instructor: Dr. Dietmar Knipp, Assistant Professor of Electrical Engineering Name: Mat. -Nr.: Guidelines: Duration of the Final Exam: 2 hour You

More information

The secondary MZM used to modulate the quadrature phase carrier produces a phase shifted version:

The secondary MZM used to modulate the quadrature phase carrier produces a phase shifted version: QAM Receiver 1 OBJECTIVE Build a coherent receiver based on the 90 degree optical hybrid and further investigate the QAM format. 2 PRE-LAB In the Modulation Formats QAM Transmitters laboratory, a method

More information

All-optical clock division at 40 GHz using a semiconductor amplifier. nonlinear interferometer

All-optical clock division at 40 GHz using a semiconductor amplifier. nonlinear interferometer All-optical clock division at 40 GHz using a semiconductor amplifier nonlinear interferometer R. J. Manning, I. D. Phillips, A. D. Ellis, A. E. Kelly, A. J. Poustie, K.J. Blow BT Laboratories, Martlesham

More information

Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid

Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid Boy Braaf, 1,* Koenraad A. Vermeer, 1 Victor Arni D.P. Sicam, 1 Elsbeth van Zeeburg, 1,2

More information

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report Introduction and Background Two-photon microscopy is a type of fluorescence microscopy using two-photon excitation. It

More information

Chad A. Husko 1,, Sylvain Combrié 2, Pierre Colman 2, Jiangjun Zheng 1, Alfredo De Rossi 2, Chee Wei Wong 1,

Chad A. Husko 1,, Sylvain Combrié 2, Pierre Colman 2, Jiangjun Zheng 1, Alfredo De Rossi 2, Chee Wei Wong 1, SOLITON DYNAMICS IN THE MULTIPHOTON PLASMA REGIME Chad A. Husko,, Sylvain Combrié, Pierre Colman, Jiangjun Zheng, Alfredo De Rossi, Chee Wei Wong, Optical Nanostructures Laboratory, Columbia University

More information

Multiply Resonant EOM for the LIGO 40-meter Interferometer

Multiply Resonant EOM for the LIGO 40-meter Interferometer LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY LIGO-XXXXXXX-XX-X Date: 2009/09/25 Multiply Resonant EOM for the LIGO

More information

Z-LASER Optoelektronik GmbH Stemmer 3d Technologietag Useful information on Z-Lasers for Vision

Z-LASER Optoelektronik GmbH Stemmer 3d Technologietag Useful information on Z-Lasers for Vision Z-LASER Optoelektronik GmbH Stemmer 3d Technologietag - 24.2.2011 Useful information on Z-Lasers for Vision The Company Core Competences How to Build a Z-LASER Electronics and Modulation Wavelength and

More information

Common Path Side Viewing Monolithic Ball Lens Probe for Optical Coherence Tomography

Common Path Side Viewing Monolithic Ball Lens Probe for Optical Coherence Tomography Common Path Side Viewing Monolithic Ball Lens Probe for Optical Coherence Tomography DOI 10.17691/stm2015.7.1.04 Received November 21, 2014 Kanwarpal Singh, PhD, Research Fellow, Wellman Center for Photomedicine,

More information

Module 12 : System Degradation and Power Penalty

Module 12 : System Degradation and Power Penalty Module 12 : System Degradation and Power Penalty Lecture : System Degradation and Power Penalty Objectives In this lecture you will learn the following Degradation during Propagation Modal Noise Dispersion

More information

Imaging Fourier transform spectrometer

Imaging Fourier transform spectrometer Rochester Institute of Technology RIT Scholar Works Theses Thesis/Dissertation Collections 2001 Imaging Fourier transform spectrometer Eric Sztanko Follow this and additional works at: http://scholarworks.rit.edu/theses

More information

Components of Optical Instruments 1

Components of Optical Instruments 1 Components of Optical Instruments 1 Optical phenomena used for spectroscopic methods: (1) absorption (2) fluorescence (3) phosphorescence (4) scattering (5) emission (6) chemiluminescence Spectroscopic

More information

Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement

Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement PHOTONIC SENSORS / Vol. 4, No. 3, 2014: 215 219 Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement Jiahong ZHANG *, Fushen CHEN, Bao SUN, and Kaixin CHEN Key Laboratory

More information