Econami Digital Sound Decoder Diesel Technical Reference Software Release 1.6

Size: px
Start display at page:

Download "Econami Digital Sound Decoder Diesel Technical Reference Software Release 1.6"

Transcription

1 Econami Digital Sound Decoder Diesel Technical Reference Software Release 16 Previous software versions included Rev E 11/14/17

2 Notice The information in this document is subject to change without notice SoundTraxx (Throttle Up! Corp) shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damage resulting from the furnishing, performance or use of this material This document contains information protected by copyright No part of this document may be photocopied or reproduced in any form without the prior written consent of Throttle Up! Corp Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies SoundTraxx, Econami, Tsunami, Tsunami2, SoundTraxx DCC, Dynamic Digital Exhaust, Auto-Exhaust, Hyperlight, Hyperdrive2, SoundCar, CurrentKeeper and Intelligent Consisting are trademarks of Throttle Up! Corp

3 Contents Primary CVs 5 CV 1: Primary Address 5 CV 2: Vstart 6 CV 3: Baseline Acceleration Rate 7 CV 4: Baseline Deceleration Rate 8 CV 5: Vhigh 9 CV 6: Vmid 10 CV 7: Manufacturer Version (Read-Only) 11 CV 8: Manufacturer ID 12 CV 10: EMF Feedback Cutout 13 CV 11: Packet Time-Out Value 14 CV 12: Alternate Power Source 15 CV 13: Analog Mode Function Enable 1 16 CV 14: Analog Mode Function Enable 2 17 CV 15: CV Unlock Code 18 CV 16: CV Lock ID 19 CVs 17-18: Extended Address 20 CV 19: Consist Address 21 CV 21: Consist Function Enable 1 22 CV 22: Consist Function Enable 2 23 CV 23: Consist Acceleration Rate 24 CV 24: Consist Deceleration Rate 25 CV 25: Speed Table Enable 26 CV 29: Configuration Data 1 27 CV 30: Error Information 28 CV 31: CV Index 1 29 CV 32: CV Index 2 30 CVs 33-46: Function Status CVs 31 CV 33: F0(f) Output Location 32 CV 34: F0(r) Output Location 33 CV 35: F1 Output Location 34 CV 36: F2 Output Location 35 CV 37: F3 Output Location 36 CV 38: F4 Output Location 37 CV 39: F5 Output Location 38 CV 40: F6 Output Location 39 CV 41: F7 Output Location 40 CV 42: F8 Output Location 41 CV 43: F9 Output Location 42 CV 44: F10 Output Location 43 CV 45: F11 Output Location 44 CV 46: F12 Output Location 45 Lighting Effect CVs 46 CVs 49-54: Hyperlight Effect Select 46 CV 57: Forward Direction Enable 50 CV 58: Reverse Direction Enable 51 CV 59: Hyperlight Flash Rate 52 CV 60: Grade-Crossing Hold Time 53 CV 61: Brightness Register 1 54 CV 62: Brightness Register 2 55 CV 63: Dimmer Level 56 Speed Table CVs 57 CV 66: Forward Motor Trim 57 CVs 67-94: Custom Speed Table 58 CV 95: Reverse Motor Trim 59

4 User Information CVs 60 CV 105: User Identifier 1 60 CV 106: User Identifier 2 61 Sound Control CVs 62 CV 113: Quiet Mode Time-Out Period 62 CV 114: Engine Exhaust Control 63 CV 117: F11 Brake Rate 65 CV 119: Max Engine Recovery Speed 66 CV 120: Airhorn Select 67 CV 121: Alternate Airhorn Select 68 CV 122: Bell Select 69 CV 123: Prime Mover Select 70 CV 124: Air Compressor Select 71 CV 126: Coupler Select 72 CV 128: Master Volume 73 CVs : Mixer Channel Volume Control 74 CV 193: Auto-Bell On Set Point 75 CV 194: Auto-Bell On Time 76 CV 195: Coach Door Count 77 CV 196: Brake Squeal Sensitivity 78 CV 197: Analog Mode Auto-Sound Enable 79 CV 198: DCC Mode Auto-Sound Enable 80 CV 200: Poppet Valve Release Rate 81 Advanced Motor Control CVs 82 CVs : Advanced Motor Control Registers 82 CV 209: PID Kp Parameter 82 CV 210: PID Ki Parameter 83 CV 211: Low-Speed Compensation 84 CV 212: BEMF Feedback Intensity 85 CV 213: BEMF Sample Period 86 CV 214: BEMF Sample Aperture Time 87 CV 215: BEMF Reference Voltage 88 CV 216: Motor Speed Step Deadband 89 CV 217: Motor Control Register 90 CV 218: Analog Mode Motor Start Voltage 91 CV 219: Analog Mode Engine Start Voltage 92 7-Band Equalizer CVs 93 CV 225: Equalizer Control Register 93 CVs : Cut/Boost Controls 94 Analog Function Enable CVs 95 CV 241: Analog Mode Function Enable 3 95 CV 242: Analog Mode Function Enable 4 96 CV 243: Analog Mode Function Enable 5 97 Consist Function Enable CVs 98 CV 245: Consist Function Enable 3 98 CV 246: Consist Function Enable 4 99 CV 247: Consist Function Enable Indexed CV Page CVs : Extended Function Mapping CVs 101 CVs : Effect Map Registers 103 CVs : Effect Auxiliary Map Registers 104

5 Primary CVs Primary CVs CV 1: Primary Address CV 1 is used to set the decoder s primary address from 1 to A6 A5 A4 A3 A2 A1 A0 A0-A6: Primary Address 0: Reserved Additional Information Entering values from 1 to 127 into CV 1 will set the primary address while in Service Mode The decoder will ignore commands that attempt to program this CV with values outside the range of 1 to 127 The decoder will process all valid instruction packets addressed with the value contained in CV 1 when bit 5 of CV 29 (Configuration Data 1) is set to 0 Entering a new value into CV 1 will: Set the value of CV 19 (Consist Address) to 0 Clear the Extended Address Mode Enable bit in CV 29 (bit 5) Bit 5 of CV 29 must be set to 1 in order for the value of CV 1 to be changed in Operations Mode Setting bit 5 of CV 29 back to 0 will then allow the decoder to recognize the new primary address Default Value: 3 Related CVs: CV (Extended Address) CV 19 (Consist Address) CV 29 (Configuration Data 1) Econami Diesel Technical Reference 5

6 CV 2: Vstart Primary CVs CV 2 is used to set the voltage level applied to the motor at speed-step 1 D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Motor Start Voltage Additional Information The motor start voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 2 will adjust the starting voltage level Starting voltage is calculated as: Starting Voltage = Supply Voltage CV When CV 2 is set to a non-zero value, the decoder will offset all points of the speed table as speed increases CV 2 is used in conjunction with CV 5 (Vhigh) and CV 6 (Vmid) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 5 (Vhigh) CV 6 (Vmid) CV 29 (Configuration Data 1) Econami Diesel Technical Reference 6

7 Primary CVs CV 3: Baseline Acceleration Rate CV 3 is used to set the decoder s acceleration rate D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Acceleration Rate Additional Information Setting CV 3 to value from 0 to 255 will adjust the acceleration rate Acceleration is calculated as: Seconds/Speed Step = CV Number of Speed Steps When the value of CV 3 is 0, acceleration will respond instantly to increases in the throttle setting When the value of CV 3 is 255, the decoder will accelerate from a stop to full speed in approximately 38 minutes Setting CV 3 to a non-zero value in 14 or 28 speed-step mode will create a smoother acceleration response; the decoder is designed to interpolate between speed steps during acceleration when CV 3 is set to a non-zero value to eliminate erratic transitions Default Value: 0 Related CVs: CV 4 (Baseline Deceleration Rate) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) Econami Diesel Technical Reference 7

8 Primary CVs CV 4: Baseline Deceleration Rate CV 4 is used to set the decoder s deceleration rate D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Deceleration Rate Additional Information A value from 0 to 255 may be entered into CV 4 to adjust the deceleration rate Deceleration is calculated as: Seconds/Speed Step = CV Number of Speed Steps When the value of CV 4 is 0, deceleration will respond instantly to decreases in the throttle setting When the value of CV 4 is 255, the decoder will decelerate from full speed to a stop in approximately 38 minutes Setting CV 4 to a non-zero value in 14 or 28 speed-step mode will create a smoother deceleration response; the decoder is designed to interpolate between speed steps during deceleration when CV 4 is set to a non-zero value to eliminate erratic transitions Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) CV 117 (F11 Brake Rate) Econami Diesel Technical Reference 8

9 CV 5: Vhigh Primary CVs CV 5 is used to set the voltage level applied to the motor at maximum speed and is active when the 3-point speed table is enabled D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Maximum Voltage Value Additional Information Maximum voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 5 will adjust the maximum speed voltage level Maximum voltage is calculated as: Maximum Voltage = Supply Voltage CV Values of 0 and 1 will disable the Vhigh speed table setting A value of 255 will set the Vhigh speed table setting to the maximum available voltage (100%) CV 5 is used in conjunction with CV 2 (Vstart) and CV 6 (Vmid) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 2 (Vstart) CV 6 (Vmid) CV 29 (Configuration Data 1) Econami Diesel Technical Reference 9

10 CV 6: Vmid Primary CVs CV 6 is used to set the voltage level applied to the motor at the middle speed step and is active when the 3-point speed table is enabled D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Midpoint Voltage Value Additional Information Midpoint voltage is calculated as a fraction of the available supply voltage Entering a value from 0 to 255 into CV 6 will adjust the mid-speed voltage level Midpoint voltage is calculated as: Midpoint Voltage = Supply Voltage CV Values of 0 and 1 will disable the Vmid speed table setting A value of 255 will set the Vmid speed table setting to the maximum available voltage (100%) CV 6 is used in conjunction with CV 2 (Vstart) and CV 5 (Vhigh) to configure the 3-point speed table The 3-point speed table is active when bit 4 (STE) of CV 29 is set to 0 and CVs 2, 5, and 6 are set to non-zero values Default Value: 0 Related CVs: CV 2 (Vstart) CV 5 (Vhigh) CV 29 (Configuration Data 1) Econami Diesel Technical Reference 10

11 Primary CVs CV 7: Manufacturer Version (Read-Only) CV 7 contains the 8-bit software version identifier CV 7 is read-only and cannot be modified D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Version Code 70 = Econami Decoder for Steam, Diesel and Electric Econami Diesel Technical Reference 11

12 Primary CVs CV 8: Manufacturer ID CV 8 is used to reset CV settings to factory defaults and contains the NMRA-issued Manufacturer ID Code (141) assigned to SoundTraxx/Throttle Up! Entering a value from 8 to 13 into CV 8 will reset the CVs defined below Bits 0-7: CV Reset 8 = Full CV reset 9 = Reset CVs = Reset CVs = Reset CVs Manufacturer ID Code: 141 Econami Diesel Technical Reference 12

13 Primary CVs CV 10: EMF Feedback Cutout CV 10 is used to gradually reduce back-emf control as locomotive speed increases D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: EMF Feedback Cutout Additional Information The BEMF intensity is defined as the amount of the BEMF signal that is fed back to the motor controller to stabilize the speed of the motor Reducing the intensity does not regulate the speed of the motor as effectively, but helps consisted locomotives from entering a push/pull scenario where one locomotive is doing all the work Per the equation below, this CV sets the speed step at which the intensity reaches zero When CV 10 is set to 0, only the value in CV 212 is used BEMF Intensity = CV 212 x (1 (speed step CV 10)) 255 Default Value: 0 Related CVs: CV 212 (BEMF Feedback Intensity) CV 213 (BEMF Sample Period) CV 214 (BEMF Sample Aperture Time) CV 215 (BEMF Reference Voltage) Econami Diesel Technical Reference 13

14 Primary CVs CV 11: Packet Time-Out Value CV 11 is used to set duration in seconds that occurs from the time the decoder receives a valid packet to the time speed-related sound effects and motor processes are deactivated D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: Packet Time-Out Value Additional Information Entering a value from 0 to 255 into CV 11 will set the packet time-out period The timeout period is calculated in seconds as follows: Time-Out Period = CV A value of 0 disables the time-out period A value of 255 sets the time-out period to approximately 1 minute The decoder maintains an internal timer that resets each time the decoder receives a valid packet In the event no valid packets are received during the time-out period, the decoder will deactivate motor processes and the locomotive will decelerate according to the value of CV 4 (Baseline Deceleration Rate) or CV 24 (Consist Deceleration Rate) Default Value: 0 Econami Diesel Technical Reference 14

15 Primary CVs CV 12: Alternate Power Source CV 12 is used to determine the alternate power source the decoder will employ when a DCC signal is not available Bit 3 (APS) of CV 29 (Configuration Data 1) must be set to 1 in order for an alternate power source to be used D0 D0: Alternate Power Source 0 = No alternate power source 1 = Analog power supply 0: Reserved Default Value: 1 Related CVs: CV 29 (Configuration Data 1) Econami Diesel Technical Reference 15

16 Primary CVs CV 13: Analog Mode Function Enable 1 CV 13 is used to enable F1-F8 function assignments for analog mode operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for information regarding function mapping F8 F7 F6 F5 F4 F3 F2 F1 F1-F8: Analog Mode Function Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation Additional Information Setting bits 0-7 to 1 will enable the F1-F8 functions active in CVs and/or CVs for analog mode operation Default Value: 0 Related CVs: CV 14 (Analog Mode Function Enable 2) CV (Function Status CVs) CV (Analog Mode Function Enable 3-5) CV (Extended Function Mapping CVs) Econami Diesel Technical Reference 16

17 Primary CVs CV 14: Analog Mode Function Enable 2 CV 14 is used to enable F0(f), F0(r), and F9-F12 function assignments for analog mode operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for information regarding function mapping 0 0 F12 F11 F10 F9 F0(r) F0(f) F0(f)-F0(r): Analog Mode F0 Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation F9-F12: Analog Mode Function Enable 0 = Function disabled for analog operation 1 = Function enabled for analog operation 0: Reserved Additional Information Setting bits 0-7 to 1 will enable the F0(f), F0(r), F9-F12 functions active in CVs and/or CVs for analog mode operation Default Value: 3 Related CVs: CV 13 (Analog Mode Function Enable 1) CV (Function Status CVs) CV (Analog Mode Function Enable 3-5) CV (Extended Function Mapping CVs) Econami Diesel Technical Reference 17

18 Primary CVs CV 15: CV Unlock Code CV 15 is used for unlocking access to the decoder s CVs D2 D1 D0 D0-D2: CV Unlock Code 0: Reserved Additional Information Entering a value from 0 to 7 into CV 15 determines the decoder s lock status CV 15 can be accessed regardless of the decoder s lock status Locked State: If the value of CV 15 is not equal to the value of CV 16 (CV Lock ID), all CVs are locked and read and write operations will be ignored Unlocked State: The decoder s CVs can be accessed only when the value of CV 15 is equal to the value of CV 16 Note: Bit 0 (CV Lock Enable) of CV 30 (Error Information) must be set to 1 in order for the lock feature in CVs 15 and 16 to be used Default Value: 0 Related CVs: CV 16 (CV Lock ID) CV 30 (Error Information) Econami Diesel Technical Reference 18

19 Primary CVs CV 16: CV Lock ID CV 16 is used in conjunction with CV 15 (CV Unlock Code) to determine the decoder s lock status CV 16 determines the lock code used to lock the decoder s CVs ID2 ID1 ID0 ID0-ID2: CV Lock Code 0: Reserved Additional Information Entering a value from 0 to 7 into CV 16 determines the decoder s lock status CV 16 can be accessed regardless of the decoder s lock status Locked State: If the value of CV 16 is not equal to the value of CV 15 (CV Unlock Code), all CVs are locked and all read and write operations will be ignored Unlocked State: The decoder s CVs will only be accessible when the value of CV 15 is equal to the value of CV 16 Note: Bit 0 (CV Lock Enable) of CV 30 (Error Information) must be set to 1 in order for the lock feature in CVs 15 and 16 to be used Default Value: 0 Related CVs: CV 15 (CV Unlock Code) CV 30 (Error Information) Econami Diesel Technical Reference 19

20 Primary CVs CVs 17-18: Extended Address CVs 17 and 18 contain the decoder s 14-bit extended address and are merged as a paired CV CV 17: Extended Address MSB A15 A14 A13 A12 A11 A10 A9 A8 CV 18: Extended Address LSB A7 A6 A5 A4 A3 A2 A1 A0 A0-A15: Extended Address Value Additional Information Most command stations recognize from addresses Bit 5 of CV 29 (Configuration Data 1) must be set to 1 for the decoder to recognize commands sent to the extended address The decoder will ignore commands sent to the primary address when bit 5 of CV 29 is set to 1 Setting bit 5 of CV 29 to 0 will enable the primary address CV 17 contains the most significant bits of the two-byte address and can be set to values from 192 to 231 (0xC0-0xE7) CV 18 contains the least significant bits of the two-byte address and can be set to values from 0 to 255 CV 17 must be set before CV 18 The decoder will ignore attempts to adjust the values of CVs 17 and 18 out-of-order CV 17 and CV 18 can be modified in Service Mode at any time, but cannot be modified in Operations Mode unless bit 5 of CV 29 is set to 0 (ie, CV 1, Primary Address is enabled) Default Value: CV 17 = 192 CV 18 = 3 (Address 0003) Related CVs: CV 1 (Primary Address CV 19 (Consist Address) CV 29 (Configuration Data 1) Econami Diesel Technical Reference 20

21 Primary CVs CV 19: Consist Address CV 19 is used to set the address and direction for advanced consist operation CDIR A6 A5 A4 A3 A2 A1 A0 A0-A6: Consist Address Value CDIR: Consist Direction 0 = Normal direction 1 = Inverted direction Additional Information Bits 0-6 (A0-A6) are used to assign the consist address from 1 to 127 Setting bit 7 (CDIR) to 1 will invert consist direction Entering a value from 1 to 127 will set the consist address from 1 to 127 for the normal direction Entering a value from 129 to 255 will set the consist address from 1 to 127 for the inverted direction Setting CV 19 to 0 or 128 will disable the consist address When CV 19 is set to a non-zero value, the decoder will ignore throttle commands sent to the decoder s primary or extended address The decoder will process valid commands sent to the consist address with the following exceptions: Long-form CV access instructions will be ignored The direction of a speed/direction command or an advanced operation command will be inverted when bit 7 (CDIR) is set to 1 Default Value: 0 Related CVs: CV 1 (Primary Address) CVs (Extended Address) CVs (Consist Function Enable 1-2) CV 23 (Consist Acceleration Rate) CV 24 (Consist Deceleration Rate) CVs (Consist Function Enable 3-5) Econami Diesel Technical Reference 21

22 Primary CVs CV 21: Consist Function Enable 1 CV 21 is used to enable F1-F8 function assignments for advanced consist operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for more information regarding function mapping F8 F7 F6 F5 F4 F3 F2 F1 F1-F8: Consist Function Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation Additional Information CV 21 is commonly used to differentiate various engines and cars of the same consist Setting bits 0-7 to 1 will enable the F1-F8 functions active in CVs and/or CVs for advanced consist operation Default Value: 0 Related CVs: CV 19 (Consist Function Enable 2) CVs (Function Status CVs) CVs (Consist Function Enable 3-5) CVs (Extended Function Mapping CVs) Econami Diesel Technical Reference 22

23 Primary CVs CV 22: Consist Function Enable 2 CV 22 is used to enable F0(f), F0(r), and F9-F12 function assignments for advanced consist operation Refer to CVs (Effect Map Registers) and/or CVs (Function Status CVs) for more information regarding function mapping 0 0 F12 F11 F10 F9 F0(r) F0(f) F0(f)-F0(r): Consist F0 Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation F9-F12: Consist Function Enable 0 = Function disabled for consist operation 1 = Function enabled for consist operation 0: Reserved Additional information CV 22 is commonly used to differentiate various engines and cars of the same consist Setting bits 0-7 to 1 will enable the F0(f), F0(r), and F9-F12 functions active in CVs and/or CVs for advanced consist operation Default Value: 0 Related CVs: CV 19 (Consist Address) CV 21 (Consist Function Enable 1) CVs (Function Status CVs) CVs (Consist Function Enable 3-5) CVs (Extended Function Mapping CVs) Econami Diesel Technical Reference 23

24 Primary CVs CV 23: Consist Acceleration Rate CV 23 is used to set the consist acceleration rate CV 19 must contain a valid consist address for the consist acceleration rate to be active SIGN D6 D5 D4 D3 D2 D1 D0 D0-D6: Consist Acceleration Offset SIGN: Sign 0 = Positive value 1 = Negative value Additional Information The value of CV 23 determines the consist acceleration rate in relation to CV 3 (Baseline Acceleration Rate) When the consist address is active, the consist acceleration rate is added to or subtracted from the decoder s baseline acceleration rate depending on the sign bit Entering a value from 1 to 127 into CV 23 will increase the consist acceleration rate from the baseline acceleration rate in CV 3 Entering values from 129 to 255 into CV 23 will decrease the consist acceleration rate from the baseline acceleration rate in CV 3 Values of 0 and 128 will disable the consist acceleration rate and the decoder will use the value in CV 3 When bit 7 (SIGN) of CV 23 is set to 0, the value added to CV 3 will be positive, where if bit 7 is set to 1, the value added to CV 3 will be negative: Acceleration is calculated as: = = 0 1 = = = = -127 Seconds/Speed Step = (CV 3 + CV 23) 0896 Number of Speed Steps Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 4 (Baseline Deceleration Rate) CV 19 (Consist Address) CV 24 (Consist Deceleration Rate) Econami Diesel Technical Reference 24

25 Primary CVs CV 24: Consist Deceleration Rate CV 24 is used to set the consist deceleration rate CV 19 must contain a valid consist address for the consist deceleration rate to be active SIGN D6 D5 D4 D3 D2 D1 D0 D0-D6: Consist Deceleration Offset SIGN: Sign 0 = Positive value 1 = Negative value Additional Information The value of CV 24 determines the consist deceleration rate in relation to CV 4 (Baseline Deceleration Rate) When the consist address is active, the consist deceleration rate is added to or subtracted from the decoder s baseline deceleration rate depending on the sign bit Entering a value from 1 to 127 into CV 24 will increase the consist deceleration rate from the baseline deceleration rate in CV 4 Entering values from 129 to 255 into CV 24 will decrease the consist deceleration rate from the baseline deceleration rate in CV 4 Values of 0 and 128 will disable the consist deceleration rate and the decoder will use the value in CV 3 When bit 7 (SIGN) of CV 24 is set to 0, the value added to CV 4 will be positive, where if bit 7 is set to 1, the value added to CV 4 will be negative: Deceleration is calculated as: = = 0 1 = = = = -127 Seconds/Speed Step = (CV 4 + CV 24) 0896 Number of Speed Steps Default Value: 0 Related CVs: CV 3 (Baseline Acceleration Rate) CV 4 (Baseline Deceleration Rate) CV 19 (Consist Address) CV 23 (Consist Acceleration Rate) Econami Diesel Technical Reference 25

26 Primary CVs CV 25: Speed Table Enable CV 25 is used in conjunction with CV 29 (Configuration Data 1) to enable the linear or 28-point speed table MIDSPD D6 D5 D4 D3 D2 D1 D0 D0-D6: Table Identifier 0 = Disabled, Speed Curves not used 1 = Disabled, Speed Curves not used 2 = Linear Speed Curve 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved 9 = Reserved 10 = Reserved 11 = Reserved 12 = Reserved 13 = Reserved 14 = Reserved 15 = Reserved 16 = User Defined Speed Table defined by CVs MIDSPD: Reserved Additional Information Speed tables are disabled by default and voltage is directly proportional to the speed step Default Value: 2 Related CVs: CV 2 (Vmid) CV 5 (Vhigh) CV 6 (Vmid) CV 29 (Configuration Data 1) CVs (Custom Speed Table) Econami Diesel Technical Reference 26

27 Primary CVs CV 29: Configuration Data 1 CV 29 contains miscellaneous configuration bits 0 0 EAM STE 0 APS F0 DIR DIR: Direction 0 = Normal direction 1 = Inverted direction F0: F0 Location 0 = 14 speed-step mode enabled 1 = 28/128 speed-step mode enabled APS: Alternate Power Source Enable 0 = NMRA-digital only 1 = Alternate power source enabled (CV 12) STE: Speed Table Enable 0 = 3-point speed table enabled (CVs 2, 5 & 6) 1 = Linear/28-point speed table (CV 25) EAM: Extended Address Mode Enable 0 = Primary address enabled (CV 1) 1 = Extended address enabled (CVs 17-18) 0: Reserved Note: Command stations that do not support the extended address can interfere with normal operation if bit 5 of CV 29 is programmed inadvertently In this situation, connect the decoder to a programming track and set bit 5 of CV 29 to 0 Default Value: 2 Related CVs: CV 1 (Primary Address) CV 2 (Vstart) CV 5 (Vhigh) CV 6 (Vmid) CV 12 (Alternate Power Source) CVs (Extended Address) CV 25 (Speed Table Enable) CVs (Custom Speed Table) Econami Diesel Technical Reference 27

28 Primary CVs CV 30: Error Information CV 30 is used to allow the decoder s CVs to be locked and unlocked with CV 15 (CV Unlock Code) and CV 16 (CV Lock ID) LCK LCK: CV Lock/Unlock Enable 0 = CV lock/unlock feature disabled 1 = CV lock/unlock feature enabled (CVs 15-16) 0: Reserved Default Value: 0 Related CVs: CV 15 (CV Unlock Code) CV 16 (CV Lock ID) Econami Diesel Technical Reference 28

29 Primary CVs CV 31: CV Index 1 CV 31 and CV 32 (CV Index 2) contain the indexed address used for accessing CVs exceeding CV 256 CV 31 contains the most significant bits of the two-byte address and enables indexed CV operation, as determined by CV 32 Note: Modifying the default value of CV 31 will disable indexed CV operation; CV 31 should never be programmed from its default value D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: CV Index MSB 16 = Indexed address Default Value: 16 Related CVs: CV 32 (CV Index 2) Econami Diesel Technical Reference 29

30 Primary CVs CV 32: CV Index 2 CV 32 provides access to CVs exceeding CV 256 and is used to select the active indexed CV page Econami for diesel models supports one indexed CV page: 1 CVs : Indexed CV Page 1 The value of CV 32 indicates the active indexed CV page CVs allow access to indexed CVs when an indexed CV page is selected in CV 32 D7 D6 D5 D4 D3 D2 D1 D0 D0-D7: CV Index LSB 1 = Indexed CV Page 1 Additional Information Entering a value of 1 into CV 32 will select Indexed CV Page 1 as the active indexed CV page Indexed CV Page 1 contains Flex-Map function mapping CVs: CVs : Effect Map Registers CVs : Effect Auxiliary Map Registers Entering a value of 0 or values from 2 to 255 into CV 32 will disable access to CVs exceeding CV 256 If your system does not allow access to CVs exceeding CV 256, contact the manufacturer for more information Default Value: 1 Related CVs: CV 31 (CV Index 1) CVs (Extended Function Mapping CVs) Econami Diesel Technical Reference 30

31 Primary CVs CVs 33-46: Function Status CVs Function Status CVs can be used to map a limited range of effects to functions F0-F12 and are included to remain consistent with NMRA Standards for DCC Configuration Variables (S-922, p7) Note: CVs are set to values of 0 by default, are a secondary method of function mapping for those wishing to use the Legacy Function Mapping associated with the prior generation of Tsunami products, and are not used to determine Econami s default function assignments CVs (Flex-Map Function Mapping CVs) provide function assignments for 28 function keys and offer comprehensive function mapping support for all of Econami s effects in an uncomplicated and versatile format However, mapping an effect to a function key (F0(f), F0(r), or F1-F12) using CVs will override the corresponding function assignment mapped within CVs Note: The use of Legacy Function Mapping and Flex-Map Function Mapping together may produce undesirable results and is not recommended Effects mapped to CV 33 (F0(f) Output Location) can be activated in the forward direction only and effects mapped to CV 34 (F0(r) Output Location) can be activated in the reverse direction only This output is bidirectional only when same effect has been mapped to both CVs The function mapping table provided below indicates the values used for mapping functions to effects All provided effects cannot be mapped to all F0-F12 functions keys Function Output Map Function Key CV HL Output BL Output Airhorn Bell FX3 Output FX4 Output Dynamic Brake Short Airhorn Reserved Reserved Dimmer Mute Reserved Brake Coupler F0(f) F0(r) F F F F F F F F F F F F Econami Diesel Technical Reference 31

32 Primary CVs CV 33: F0(f) Output Location CV 33 is used to map a given effect to the F0(f) function key The enabled effect will be activated when the F0(f) function is turned on Disabled effects will have no relation to the F0(f) function key SAH DYN FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Econami Diesel Technical Reference 32

33 Primary CVs CV 34: F0(r) Output Location CV 34 is used to map a given effect to the F0(r) function key The enabled effect will be activated when the F0(r) function is turned on Disabled effects will have no relation to the F0(r) function key SAH DYN FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Econami Diesel Technical Reference 33

34 Primary CVs CV 35: F1 Output Location CV 35 is used to map a given effect to the F1 function key The enabled effect will be activated when the F1 function is turned on Disabled effects will have no relation to the F1 function key SAH DYN FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Econami Diesel Technical Reference 34

35 Primary CVs CV 36: F2 Output Location CV 36 is used to map a given effect to the F2 function key The enabled effect will be activated when the F2 function is turned on Disabled effects will have no relation to the F2 function key SAH DYN FX4 FX3 BEL AH BL HL HL: Headlight Output 0 = Headlight disabled 1 = Headlight enabled BL: Backup Light Output 0 = Backup light disabled 1 = Backup light enabled AH: Airhorn 0 = Airhorn disabled 1 = Airhorn enabled BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled Default Value: 0 Econami Diesel Technical Reference 35

36 Primary CVs CV 37: F3 Output Location CV 37 is used to map a given effect to the F3 function key The enabled effect will be activated when the F3 function is turned on Disabled effects will have no relation to the F3 function key DIM 0 0 SAH DYN FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 36

37 Primary CVs CV 38: F4 Output Location CV 38 is used to map a given effect to the F4 function key The enabled effect will be activated when the F4 function is turned on Disabled effects will have no relation to the F4 function key DIM 0 0 SAH DYN FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 37

38 Primary CVs CV 39: F5 Output Location CV 39 is used to map a given effect to the F5 function key The enabled effect will be activated when the F5 function is turned on Disabled effects will have no relation to the F5 function key DIM 0 0 SAH DYN FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 38

39 Primary CVs CV 40: F6 Output Location CV 40 is used to map a given effect to the F6 function key The enabled effect will be activated when the F6 function is turned on Disabled effects will have no relation to the F6 function key DIM 0 0 SAH DYN FX4 FX3 BEL BEL: Bell 0 = Bell disabled 1 = Bell enabled FX3: FX3 Output 0 = FX3 disabled 1 = FX3 enabled FX4: FX4 Output 0 = FX4 disabled 1 = FX4 enabled DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 39

40 Primary CVs CV 41: F7 Output Location CV 41 is used to map a given effect to the F7 function key The enabled effect will be activated when the F7 function is turned on Disabled effects will have no relation to the F7 function key BRK 0 MUT DIM 0 0 SAH DYN DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 40

41 Primary CVs CV 42: F8 Output Location CV 42 is used to map a given effect to the F8 function key The enabled effect will be activated when the F8 function is turned on Disabled effects will have no relation to the F8 function key BRK 0 MUT DIM 0 0 SAH DYN DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 41

42 Primary CVs CV 43: F9 Output Location CV 43 is used to map a given effect to the F9 function key The enabled effect will be activated when the F9 function is turned on Disabled effects will have no relation to the F9 function key BRK 0 MUT DIM 0 0 SAH DYN DYN: Dynamic Brake 0 = Dynamic brake disabled 1 = Dynamic brake enabled SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 42

43 Primary CVs CV 44: F10 Output Location CV 44 is used to map a given effect to the F10 function key The enabled effect will be activated when the F10 function is turned on Disabled effects will have no relation to the F10 function key CPL BRK 0 MUT DIM 0 0 SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 43

44 Primary CVs CV 45: F11 Output Location CV 45 is used to map a given effect to the F11 function key The enabled effect will be activated when the F11 function is turned on Disabled effects will have no relation to the F11 function key CPL BRK 0 MUT DIM 0 0 SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 44

45 Primary CVs CV 46: F12 Output Location CV 46 is used to map a given effect to the F12 function key The enabled effect will be activated when the F12 function is turned on Disabled effects will have no relation to the F12 function key CPL BRK 0 MUT DIM 0 0 SAH SAH: Short Airhorn 0 = Short airhorn disabled 1 = Short airhorn enabled DIM: Dimmer 0 = Dimmer disabled 1 = Dimmer enabled MUT: Mute 0 = Mute disabled 1 = Mute enabled CPL: Coupler 0 = Coupler disabled 1 = Coupler enabled BRK: Brake 0 = Bake disabled 1 = Brake enabled 0: Reserved Default Value: 0 Econami Diesel Technical Reference 45

46 Lighting Effect CVs Lighting Effect CVs CVs 49-54: Hyperlight Effect Select CVs are used to configure up to six lighting outputs with Hyperlight lighting effects and other lighting features Bit definitions for CVs are identical CV 49: Headlight Configuration (F0(f) by default) CV 50: Backup Light Configuration (F0(r) by default) CV 51: FX3 Configuration (F24 by default) CV 52: FX4 Configuration (F25 by default) CV 53: FX5 Configuration (F26 by default) ** CV 54: FX6 Configuration (F27 by default) ** ** Available on select formats LED XING PHSE EF4 EF3 EF2 EF1 EF0 EF0-EF4: Hyperlight Effect Select 0 = On/off output 1 = Dimmable on/off headlight 2 = Mars Light 3 = Pyle-National Gyralite 4 = Oscillating headlight 5 = Single-flash strobe 1 6 = Double-flash strobe 7 = Western-Cullen D312 Rotary Beacon 8 = Prime Stratolite 9 = Ditch light type I 10 = Ditch light type II 11 = Flashing rear-end device (FRED) 12 = Engine exhaust flicker 13 = Firebox flicker 14 = Reserved 15 = Dyno-light 16 = Auto-dim forward 17 = Auto-dim reverse 18 = Brake light 19 = On/off brightness 1 20 = On/off brightness 2 21 = Emergency Gyralite 22 = Reserved 23 = Ash pan flicker 24 = Reserved 25 = Single-flash strobe 2 Econami Diesel Technical Reference 46

47 Lighting Effect CVs PHSE: Phase Select 0 = Phase A 1 = Phase B XING: Grade-Crossing Logic Enable 0 = Grade-Crossing Logic disabled 1 = Grade-Crossing Logic enabled LED: LED Compensation Mode Enable 0 = Incandescent-compatible outputs enabled 1 = LED-compatible outputs enabled Additional Information On/Off Output On/Off Output The on/off lighting effect provides on/off control for the corresponding function Use this effect when the function output is being utilized to drive external electronics such as a low power relay to control a smoke generator or a servo motor Dimmable On/Off Headlight The output set to the dimmable headlight will be reduced to the brightness setting in CV 63 when you turn on the dimmer function (F7 by default) Mars Light The Mars light warning beacon follows the famous figure-eight sweep pattern and oscillates more rapidly than the Gyralite Pyle-National Gyralite The Pyle-National Gyralite is similar to the Mars Light, but oscillates in a circular or elliptical pattern Oscillating Headlight The dual-oscillating headlight generates two beams that follow each other in a tight, circular sweep pattern Single-Flash Strobes 1 and 2 The xenon single-flash strobe 1 effect flashes once during each flash rate timing cycle The xenon single-flash strobe 2 flashes once during each flash rate timing cycle, but at a slightly faster rate This effect allows you to mimic warning lights found on many Amtrak locomotives as well as remote control operated (or RCO ) locomotives Double-Flash Strobe The xenon double-flash strobe effect emits two rapid flashes of light during each flash rate timing cycle CV 59 is used to modify the flash rate timing cycle Western-Cullen D312 Rotary Beacon The Western-Cullen D312 Rotary Beacon effect follows a revolving reflector and bulb assembly flash-pattern Econami Diesel Technical Reference 47

48 Lighting Effect CVs Prime Stratolite The Stratolite is made up of four individual lamps arranged in a circular pattern The Stratolite flashes in a clockwise direction in a mechanical stepped fashion, unlike the smooth motion of the rotary beacon Ditch Lights Type I and II Ditch lights type I and II flash together by default When Grade-Crossing Logic is enabled, ditch light I assumes a steady on state before and after the crossing hold timer countdown Conversely, ditch light II will remain off before and after the crossing hold timer countdown To configure alternating ditch lights, set one lighting output to ditch light I or II and enable Grade-Crossing Logic, and then set a second lighting output to the same ditch light and enable Grade-Crossing Logic and phase offset FRED (Flashing Rear End Device) The FRED effect is a flashing red taillight that indicates the rear of the train Engine Exhaust Flicker This effect produces a random flicker whose intensity increases with locomotive speed This effect is best used by placing a red/orange LED in the exhaust stack As the locomotive increases speed, it will glow brighter, imitating an increase in sparks and exhaust gases Dyno-Light In a diesel locomotive, the lights will fade on and fade off to simulate the heating and cooling of the bulb filaments Auto-Dim Forward and Reverse The auto-dim forward effect will automatically dim lighting outputs to the dimmer level in CV 63 when in the forward direction, and the auto-dim reverse effect will automatically dim lighting outputs to the dimmer level in CV 63 when in the reverse direction Brake Light The brake light effect is dimmed to the brightness setting in CV 63 when active The brake light brightness level will be automatically set to 100% when you turn on the independent or train brake function (F11 by default) On/Off Brightness 1 and 2 On/Off Brightness effects 1 and 2 allow you to independently adjust the level of up to 2 lighting outputs You can accurately recreate low brilliance lighting effects on your model such as class lights, lit number boards or marker lamps The on/off brightness 1 and 2 effects will set lighting outputs to the brightness levels of CVs 61 and 62, respectively Emergency Gyralite The emergency Gyralite follows the same oscillating sweep pattern as the Gyralite, and will automatically disable all active lighting effects Phase Offset Add a value of 32 to the value of flashing Hyperlight effects to set the corresponding lighting output to Phase B from Phase A Flashing effects set to Phase B will flash opposite of flashing effects set to Phase A, ie, Phase A turns off when Phase B turns on, and Phase A turns on when Phase B turns off Econami Diesel Technical Reference 48

49 Lighting Effect CVs Grade-Crossing Logic Grade-Crossing Logic allows you to set up lighting functions, the bell, and airhorn to automatically simulate encountering grade crossings Add a value of 64 to enable Grade-Crossing Logic Turning on the long airhorn function (F2 by default) or the gradecrossing signal function (F9 by default) will start the crossing hold timer countdown and allow lighting effects to assume a flashing state Shown in Table F, flashing Hyperlight effects will return to an on or off state after the countdown ends You can adjust the crossing hold timer countdown from 0 to 15 seconds by entering a value from 0 to 15 into CV 60 (Grade-Crossing Hold Time) Refer to Table F located below for a list of Hyperlight effects commonly configured with Grade Crossing Logic (including alternating ditch lights) and corresponding CV values Table F Commonly Configured Hyperlight Effects CV Value Crossing Logic Crossing Logic Effect Type Off On Phase A Phase B Phase A Phase B Grade Crossing Logic Effect State Mars Light On Pyle-National Gyralite On Oscillating Headlight On Single-Flash Strobe Off Single-Flash Strobe Off Double-Flash Strobe Off D312 Rotary Beacon Off Prime Stratolite Off Ditch Light I On Ditch Light II Off FRED Off LED Compensation Mode The brightness of an incandescent bulb is determined by voltage, whereas an LED s brightness is determined by current LED Compensation Mode alters the method of sending current to the LED to balance the LED and incandescent brightness levels Add a value of 128 to enable LED Compensation Mode for the corresponding lighting output Note: Enabling LED Compensation Mode will not change the output voltage Resistors may still be necessary depending on the board format and drive voltage of the LED Default Value: Related CVs: CV 49 = Varies by software version CV 50 = Varies by software version CVs = 0 CVs (Lighting Effect CVs) Econami Diesel Technical Reference 49

50 Lighting Effect CVs CV 57: Forward Direction Enable CV 57 (Forward Direction Enable) and CV 58 (Reverse Direction Enable) are used to determine the directionality of the FX lighting outputs Use CV 57 to enable a lighting output for the forward direction 0 0 FX6 FX5 FX4 FX3 BL HL HL: Headlight Forward Enable 0 = Headlight output disabled in forward direction 1 = Headlight output enabled in forward direction BL: Backup Light Forward Enable 0 = Backup light output disabled in forward direction 1 = Backup light output enabled in forward direction FX3-FX6: FX3-FX6 Forward Enable 0 = FX output disabled in forward direction 1 = FX output enabled in forward direction 0: Reserved Additional Information Setting bits 0-5 to 1 will enable the corresponding lighting output for the forward direction A given lighting output can be made bidirectional by setting corresponding bits of CVs 57 and 58 Refer to indexed CVs (Extended Function Mapping CVs) for information regarding mapping functions to lighting outputs Default Value: Software versions 11 through 13: 253 Software version 15 and higher: 61 Related CVs: CVs (Hyperlight Effect Select) CV 58 (Reverse Direction Enable) CVs (Extended Function Mapping CVs) Econami Diesel Technical Reference 50

51 Lighting Effect CVs CV 58: Reverse Direction Enable CV 58 (Reverse Direction Enable) and CV 57 (Forward Direction Enable) are used to determine the directionality of the FX outputs Use CV 58 to enable a lighting output for the reverse direction 0 0 FX6 FX5 FX4 FX3 BL HL HL: Headlight Reverse Enable 0 = Headlight output disabled in reverse direction 1 = Headlight output enabled in reverse direction BL: Backup Light Reverse Enable 0 = Backup light output disabled in reverse direction 1 = Backup light output enabled in reverse direction FX3-FX6: FX3-FX6 Reverse Enable 0 = FX output disabled in reverse direction 1 = FX output enabled in reverse direction 0: Reserved Additional Information Setting bits 0-5 to 1 will enable the corresponding lighting output for the reverse direction A given lighting output can be made bidirectional by setting corresponding bits of CVs 57 and 58 Refer to indexed CVs (Extended Function Mapping CVs) for information regarding mapping functions to lighting outputs Default Value: Software versions 11 through 13: 254 Software version 15 and higher: 62 Related CVs: CVs (Hyperlight Effect Select) CV 57 (Forward Direction Enable) CVs (Extended Function Mapping CVs) Econami Diesel Technical Reference 51

52 Lighting Effect CVs CV 59: Hyperlight Flash Rate CV 59 is used to set the flash rate of all enabled flashing Hyperlight effects FR3 FR2 FR1 FR0 FR0-FR3: Hyperlight Flash Rate Select 0 = Fastest flash rate 15 = Slowest flash rate 0: Reserved Default Value: Software versions 11 through 13: 2 Software version 15 and higher: 3 Related CVs: CVs (Hyperlight Effect Select) CV 60 (Grade-Crossing Hold Time) Econami Diesel Technical Reference 52

Econami Digital Sound Decoder Steam Technical Reference Software Release 1.6

Econami Digital Sound Decoder Steam Technical Reference Software Release 1.6 Econami Digital Sound Decoder Steam Technical Reference Software Release 16 Previous software versions included Rev H 11/14/17 Notice The information in this document is subject to change without notice

More information

Tsunami2 Digital Sound Decoder Electric Technical Reference Software Release 1.2 **

Tsunami2 Digital Sound Decoder Electric Technical Reference Software Release 1.2 ** Tsunami2 Digital Sound Decoder Electric Technical Reference Software Release 12 ** ** Previous software version included Rev C 11/08/17 Notice The information in this document is subject to change without

More information

Tsunami2 Digital Sound Decoder Steam Technical Reference Software Release 1.2 **

Tsunami2 Digital Sound Decoder Steam Technical Reference Software Release 1.2 ** Tsunami2 Digital Sound Decoder Steam Technical Reference Software Release 12 ** ** Previous software versions included Rev D 11/08/17 Notice The information in this document is subject to change without

More information

Tsunami Digital Sound Decoder. Quick Start Guide for the Blackstone Models C-19

Tsunami Digital Sound Decoder. Quick Start Guide for the Blackstone Models C-19 Tsunami Digital Sound Decoder Quick Start Guide for the Blackstone Models C-19 May 2011 Notice The information in this document is subject to change without notice. Neither Blackstone Models or SoundTraxx

More information

Copies of the NMRA DCC Standards and Recommended Practices may be obtained by contacting:

Copies of the NMRA DCC Standards and Recommended Practices may be obtained by contacting: Scope This section of the manual is designed to provide the advanced user with additional insight into the operation and capabilities of the SoundTraxx Digital Sound Decoder. By necessity, it is somewhat

More information

NIMFT-B Decoder $ Plug and play decoder for Intermountain FT-B units

NIMFT-B Decoder $ Plug and play decoder for Intermountain FT-B units NIMFT-B Decoder Plug and play decoder for Intermountain FT-B units $29.95 This is an EPF (extended packet format) decoder supporting: Silent Running TM motor drive eliminates annoying motor hum or buzz

More information

POWER PRO. Digital Command Control. D14SRP Decoder. Decoder version 3.2 $29.95

POWER PRO. Digital Command Control. D14SRP Decoder. Decoder version 3.2 $29.95 Technical Reference for the TM POWER PRO Digital Command Control D4SRP Decoder Dimensions:.8 x.65 inches 27 x 6.5 mm Decoder version 3.2 $29.95 This decoder is designed specifically to fit decoders with

More information

POWERHOUSE Digital Command Control

POWERHOUSE Digital Command Control Technical Reference TM POWERHOUSE Digital Command Control SW9-SR Drop-In Decoder Dimensions:.95 x.83 x.2 inches 5 x 2 x 3. mm Version 3.2 $29.95 This decoder is designed for easy installation in Lifelike

More information

N12SR Decoder. $29.95 Decoder version 3.3 Dimensions: 0.34 x 0.70 x.12 inches x 18 x 3.2 mm

N12SR Decoder. $29.95 Decoder version 3.3 Dimensions: 0.34 x 0.70 x.12 inches x 18 x 3.2 mm N12SR Decoder $29.95 Decoder version 3.3 Dimensions: 0.34 x 0.70 x.12 inches - 8.6 x 18 x 3.2 mm This is an EPF (extended packet format) decoder supporting: Silent Running TM motor drive eliminates annoying

More information

POWER PRO Digital Command Control

POWER PRO Digital Command Control Technical Reference for the TM POWER PRO Digital Command Control D13SR Decoder Dimensions: 1.65 x 0.630 x.120 inches 42 x 16.5 x 3.2 mm Decoder version 3.2 $29.95 This is an EPF (extended packet format)

More information

POWER PRO. Digital Command Control. DA-SR Decoder. Decoder version 3..2 $29.95

POWER PRO. Digital Command Control. DA-SR Decoder. Decoder version 3..2 $29.95 Technical Reference for the TM POWER PRO Digital Command Control DA-SR Decoder Dimensions: 2.85 x.66 x.2 inches 72 x 7 x 3.2 mm Decoder version 3..2 $29.95 Atlas GP38, GP, RS/2/3, C2/5, GP7, RSD/5/2, C3-7,

More information

When shipped from factory default operating mode is mobile(loco) decoder; "Loco address 3"

When shipped from factory default operating mode is mobile(loco) decoder; Loco address 3 Light-it, Notes to self When shipped from factory default operating mode is mobile(loco) decoder; "Loco address 3" Factory rest set CV128 to value of 170; "sets decoder back to factory settings" Can be

More information

Combi-Decoder SL51-4 for OO/HO

Combi-Decoder SL51-4 for OO/HO www.tran.at Combi-Decoder SL51-4 for OO/HO Translation to English and annotation by YouChoos (www.youchoos.co.uk) 3 rd edition, October 2011 Technical data and installation Track voltage DCC 7-24V Maximum

More information

Multi-protocol decoder with Load Regulation for Locomotives with 21-way connector

Multi-protocol decoder with Load Regulation for Locomotives with 21-way connector Multi-protocol decoder with Load Regulation for Locomotives with 2-way connector Features Locomotive Decoder Multi-protocol decoder with load regulation for DCC and Motorola Suitable for DC and Bell armature

More information

SRVODRV REV7 INSTALLATION NOTES

SRVODRV REV7 INSTALLATION NOTES SRVODRV-8020 -REV7 INSTALLATION NOTES Thank you for purchasing the SRVODRV -8020 drive. The SRVODRV -8020 DC servo drive is warranted to be free of manufacturing defects for 1 year from the date of purchase.

More information

Multi-protocol Decoder with load regulation for DC and Faulhaber Motors Features Description

Multi-protocol Decoder with load regulation for DC and Faulhaber Motors Features Description Multi-protocol Decoder with load regulation for DC and Faulhaber Motors Features Regulated Multi-protocol decoder for DCC, Motorola Suitable for DC and Bell armature motors up to.7a Quiet motor running

More information

Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation

Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation Quick Parameter List: 0x00: Device Number 0x01: Required Channels 0x02: Ignored Channels 0x03: Reversed Channels 0x04: Parabolic

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

CV list expert s searching tool Version: October 2018

CV list expert s searching tool Version: October 2018 CV list expert s searching tool Version: October 2018 This CV list is an addition to the instruction manual for ZIMO driving decoders. The left column shows the chapters of the ZIMO instruction manual

More information

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup. Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2

More information

TAM VALLEY DEPOT. Quad-LN User Manual. Gen2 Firmware v1.1

TAM VALLEY DEPOT. Quad-LN User Manual. Gen2 Firmware v1.1 TAM VALLEY DEPOT Quad-LN User Manual Gen2 Firmware v1.1 N3IX Engineering 20 Aug 2013 Contents 1 Basics... 1 1.1 Overview... 1 1.2 Servos... 1 1.3 External Power Supply... 1 1.4 Onboard LED Indicators...

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

TEAM DIGITAL. Servette TM Single Servo Controller

TEAM DIGITAL. Servette TM Single Servo Controller 12 7 Summary of Configuration Variables CV# Function/Default Value CV# Function/Default Value 1 Servo Address 1 43 reserved - 2 reserved - 44 Sec Input Control 26 3 Servo Move Range 15 45 reserved - 4

More information

PID-CONTROL FUNCTION AND APPLICATION

PID-CONTROL FUNCTION AND APPLICATION PID-CONTROL FUNCTION AND APPLICATION Hitachi Inverters SJ1 and L1 Series Deviation - P : Proportional operation I : Integral operation D : Differential operation Inverter Frequency command Fan, pump, etc.

More information

Release 0.3. Rolling Thunder Technical Reference Manual

Release 0.3. Rolling Thunder Technical Reference Manual Release 0.3 Rolling Thunder Technical Reference Manual INTRODUCTION Introduction Rolling Thunder consists of one transmitter in a Paragon 3 Rolling Thunder equipped locomotive and one Rolling Thunder receiver

More information

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium basalte bvba hundelgemsesteenweg a 980 merelbeke belgium / 68 06 basalte Table of contents:. Introduction... 3. Installation... 4. 3. Identifying the parts... 5 General... 6 3. General functions... 7 3.

More information

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control Installation Guide MMTM/PB Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control Programmable between 1 minute and 30 minutes, in 1 minute steps Suitable

More information

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER AC DRIVE PARAMETERS. In This Chapter... CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4

More information

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code

More information

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD. RYKO Manufacturing Company 116 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 5111 Phone (515) 986-37 www.ryko.com Fax (515) 986-3621 sales@ ryko.com INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+

More information

Signalist SC2. DCC servo point controller user manual

Signalist SC2. DCC servo point controller user manual Signalist SC2 DCC servo point controller user manual 1 Contents Signalist SC2 user manual... 3 Overview... 3 Connections... 3 Power connection... 4 Accessory bus connection... 5 Track connection... 6 Frog

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

QuickBuilder PID Reference

QuickBuilder PID Reference QuickBuilder PID Reference Doc. No. 951-530031-006 2010 Control Technology Corp. 25 South Street Hopkinton, MA 01748 Phone: 508.435.9595 Fax: 508.435.2373 Thursday, March 18, 2010 2 QuickBuilder PID Reference

More information

TEAM DIGITAL. SMC4 Servo & Motor Controller

TEAM DIGITAL. SMC4 Servo & Motor Controller 16 CV# Function/Default Value CV# Function/Default Value 28 reserved - 73 Servo 3 Behavior 0 29 Decoder Configuration 0 74 Servo 4 Behavior 0 30 reserved - 75 Output Flash 0 31 Ops Mode Loco Address 1

More information

Mercury technical manual

Mercury technical manual v.1 Mercury technical manual September 2017 1 Mercury technical manual v.1 Mercury technical manual 1. Introduction 2. Connection details 2.1 Pin assignments 2.2 Connecting multiple units 2.3 Mercury Link

More information

6.9 Jump frequency - Avoiding frequency resonance

6.9 Jump frequency - Avoiding frequency resonance E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant

More information

WMX2 Parameter Manual

WMX2 Parameter Manual WMX2 Parameter Manual Revision 2.0030 2016 Soft Servo Systems, Inc. Warning / Important Notice Warning The product described herein has the potential through misuse, inattention, or lack of understanding

More information

Operation Instruction Manual KAM-TC1000. Precision Temperature Controller

Operation Instruction Manual KAM-TC1000. Precision Temperature Controller Kamweld Industries Inc. Operation Instruction Manual KAM-TC1000 Precision Temperature Controller Introduction Thank you for purchasing Kamweld's Percision temperature controller, KAM-TC1000. We sincerely

More information

TEAM DIGITAL. SC82 Servo Controller

TEAM DIGITAL. SC82 Servo Controller TEAM DIGITAL SC Servo Controller Improving the world of DCC > DCC compatible accessory decoder > Control servos motors > Output status LEDs > inputs for turnout control > 6 inputs for semaphore signaling

More information

MX620 - MX623, MX630 - MX633

MX620 - MX623, MX630 - MX633 Decoder MX62 - MX623, MX63 - MX633 and Sound Decoder MX64 - MX648 Page 1 MX63 INSTRUCTION MANUAL MX621 MX642D MX621N MX63P16 PluX 16 MX632 MX632D 21-pin MTC MX642 PluX 22 MX643P22 SUBMINIATURE and MINIATURE

More information

VL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02

VL1000 Software Version History VL1000 3/25/02 4/10/02 4/15/02 4/25/02 5/16/02 6/25/02 7/09/02 8/08/02 Page 1 of 5 SUBJECT: VL1000 Luminaire Software Version History SERIES: 1000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction VL1000 Software Version History This technical bulletin

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement

More information

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE G320X MANUAL DC BRUSH SERVO MOTOR DRIVE Thank you for purchasing the G320X drive. The G320X DC servo drive is warranted to be free of manufacturing defects for 3 years from the date of purchase. Any customer

More information

TAM VALLEY DEPOT. QuadLN_S User Manual

TAM VALLEY DEPOT. QuadLN_S User Manual TAM VALLEY DEPOT QuadLN_S User Manual Firmware v1.0 N3IX Engineering 25 August 2014 N3IX Engineering 2014 Contents 1 Basics... 1 1.1 Overview... 1 1.2 Servos... 2 1.3 External Power Supply... 2 1.4 Onboard

More information

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

Enhanced PID for Air Compressors F7 Drive Software Technical Manual Software Number: VSF11020X, Drive Models: CIMR-F7UXXXXXX-096 Document Number: TM.F7SW.096, Date: 08/01/05, Rev: 05-08 Enhanced PID for Air Compressors F7 Drive Software Technical Manual This document is

More information

[ 4 ] Using pulse train input (F01 = 12)

[ 4 ] Using pulse train input (F01 = 12) [ 4 ] Using pulse train input (F01 = 12) Selecting the pulse train input format (d59) A pulse train in the format selected by the function code d59 can give a frequency command to the inverter. Three types

More information

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: User Parameters 0-00 Identity Code of AC Drive Factory setting: d# Settings None V HP 1/4 1/2 1 2 3 11V/230V d0 d2 d4 d6 d8 460V -- -- -- d3 d d7 d9

More information

Digital-Servo Analogue Operation. Charateristics. Description. Connection

Digital-Servo Analogue Operation. Charateristics. Description. Connection Digital-Servo 8 3 Charateristics For Märklin oder DCC Digital systems and Analogue operation Integrated Digital decoder Switchable by locomotive functions, solenoid or proportional to speed setting Configurable

More information

Introduction To Temperature Controllers

Introduction To Temperature Controllers Introduction To Temperature Controllers The Miniature CN77000 is a full featured microprocessor-based controller in a 1/16 DIN package. How Can I Control My Process Temperature Accurately and Reliably?

More information

Continental Hydraulics Installation Manual CEM-PA-A

Continental Hydraulics Installation Manual CEM-PA-A CEMPAA Description: This closed loop PID amplifier drives a single solenoid proportional pressure or flow control valve coil up to 2.6A. It is suitable to provide precise closed loop control in pressure,

More information

RailLinx 900 Control System. Operation Manual

RailLinx 900 Control System. Operation Manual RailLinx 900 Control System Operation Manual RCS America RailLinx 900 Control System Operation Manual This manual was written by RCS America Any questions, please don t hesitate to call. RCS America 2818

More information

CT435. PC Board Mount Temperature Controller

CT435. PC Board Mount Temperature Controller CT435 PC Board Mount Temperature Controller Features Two RTD temperature sensor inputs: Pt100 or Pt1000. Wide temperature sensing range: -70 C to 650 C. All controller features are configurable through

More information

Procidia Control Solutions Dead Time Compensation

Procidia Control Solutions Dead Time Compensation APPLICATION DATA Procidia Control Solutions Dead Time Compensation AD353-127 Rev 2 April 2012 This application data sheet describes dead time compensation methods. A configuration can be developed within

More information

Introduction. Purpose

Introduction. Purpose Page 1 of 6 SUBJECT: VL1000 / VL2000 Luminaire Software SERIES: 1000/2000 DISTRIBUTION: Service Centers, End Users STATUS: Routine Introduction 10 minutes Purpose Software Version 4.8 containing updated

More information

DI 24 VDC. Stepper Axis. Dual Stepper Motion Module Applications Guide. 8 Digital Input +24 VDC Sourcing. Stepper. Contents. Programming a Stepper...

DI 24 VDC. Stepper Axis. Dual Stepper Motion Module Applications Guide. 8 Digital Input +24 VDC Sourcing. Stepper. Contents. Programming a Stepper... Dual Stepper Motion Module Applications Guide Stepper Stepper Axis DI 24 VDC 8 Digital Input +24 VDC Sourcing Contents Programming a Stepper...5 Setting Up Stepper Motor Operating Parameters...5 Setting

More information

INSTRUCTION MANUAL. Non-Sound Decoder MX618 - MX634 and Sound Decoder MX640 - MX648 Page 1

INSTRUCTION MANUAL. Non-Sound Decoder MX618 - MX634 and Sound Decoder MX640 - MX648 Page 1 Non-Sound Decoder MX618 - MX634 and Sound Decoder MX64 - MX648 Page 1 INSTRUCTION MANUAL MX618N18 Next 18 NEM 651 MX621N MX632 MX63 MTC 21 MX644C MX63P16 PluX 16 NEXT 18 DECODER SUBMINIATURE and MINIATURE

More information

Speed Feedback and Current Control in PWM DC Motor Drives

Speed Feedback and Current Control in PWM DC Motor Drives Exercise 3 Speed Feedback and Current Control in PWM DC Motor Drives EXERCISE OBJECTIVE When you have completed this exercise, you will know how to improve the regulation of speed in PWM dc motor drives.

More information

Multi-function, Compact Inverters. 3G3MV Series

Multi-function, Compact Inverters. 3G3MV Series Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat

More information

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR 40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a

More information

Copley ASCII Interface Programmer s Guide

Copley ASCII Interface Programmer s Guide Copley ASCII Interface Programmer s Guide PN/95-00404-000 Revision 4 June 2008 Copley ASCII Interface Programmer s Guide TABLE OF CONTENTS About This Manual... 5 Overview and Scope... 5 Related Documentation...

More information

Manual. ihss57-xx. Integrate Stepper Servo Motor.

Manual. ihss57-xx. Integrate Stepper Servo Motor. ihss57-xx Integrate Stepper Servo Motor Manual Shenzhen Just Motion Control Electro-mechanics Co., Ltd TEL:+86-0755-26509689 FAX:+86-0755-26509289 www.jmc-motion.com Email:jmk@jmc-motion.com Address: Floor2,

More information

MX620, MX62, MX63, MX64, MX64D, MX64P

MX620, MX62, MX63, MX64, MX64D, MX64P Decoder MX62, MX62, MX63, MX64, MX64D, MX64P Page 1 INSTRUCTION MANUAL EDITION First common instruction manual for MX62 (SW version 3), MX62, MX63, MX64 (SW version 25) --- 26 8 1 26 9 2 26 12 1 RailCom

More information

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG 2 490 0 220 DME 2 490 0 221 DMB 2 490 0 222 Date: Aug-07 (subject to alterations) Page 1 of 36 Contents 1 FUNCTIONAL CHARACTERISTICS...

More information

LEDsmart + Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

LEDsmart + Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control DIGINET CONTROL SYSTEMS DATA SHEET LEDsmart + Programmable between 1 minute and 30 minutes with built in multi-way control www.diginet.net.au Wall plate not included Range Overview MMTM / PB Designed in

More information

USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector

USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector 575W HMI Scan light ZIPPER 575 USER S MANUAL This manual must be considered an integral part of the projector. The user must read this manual before using the projector AUTHORISED AND QUALIFIED PERSONNEL

More information

Fibaro System Modules

Fibaro System Modules Chapter 3 Fibaro System Modules 3.1 Fibaro Dimmer FGD211 Figure 3.1: Dimmer module, FGD-211 Radio controlled light dimming module, designed to work with light sources of any type. May be connected to two-wire

More information

Bulletin 1402 Line Synchronization Module (LSM)

Bulletin 1402 Line Synchronization Module (LSM) Bulletin 1402 (LSM) Application Notes Table of Contents What is Synchronization?...................................... 2 Synchronization............................................. 3 1771 Modules and

More information

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 PARAMETER SUMMARY CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions

More information

Final Mini Project Report

Final Mini Project Report Integrated System Analysis Team 1 Savath Lieng: Leader Jose Diaz: Certifier Shabuktagin Photon Khan: Rapporteur Abstract This mini project III shows an integrated system analysis. In this project, we built

More information

recognise that electronic systems are assembled from sensing, processing and out put sub-systems, including:

recognise that electronic systems are assembled from sensing, processing and out put sub-systems, including: Electronic Systems Learners should be able to: (a) recognise that electronic systems are assembled from sensing, processing and out put sub-systems, including: sensing units: light, temperature, magnetic

More information

RB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver

RB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver RB-Rop-08 Scorpion XXL Dual 20A 6V to 28V R/C DC Motor Driver The Robot Power Scorpion XXL is a flexible high-performance two-channel motor controller for small to medium mobile robots such as firefighting

More information

Automationdirect.com. D i r e c t L o g i c L o o p P I D C o p r o c e s s o r F P I D

Automationdirect.com. D i r e c t L o g i c L o o p P I D C o p r o c e s s o r F P I D Automationdirect.com D i r e c t L o g i c 4 0 5 1 6 L o o p P I D C o p r o c e s s o r F 4-1 6 P I D Order Number: F4-16PID-M TRADEMARKS Automationdirect.com is a Trademark of Automationdirect.com CoProcessor

More information

DACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557*

DACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557* a FEATURES Complete 8-Bit DAC Voltage Output 0 V to 2.56 V Internal Precision Band-Gap Reference Single-Supply Operation: 5 V ( 10%) Full Microprocessor Interface Fast: 1 s Voltage Settling to 1/2 LSB

More information

Introduction to Servo Control & PID Tuning

Introduction to Servo Control & PID Tuning Introduction to Servo Control & PID Tuning Presented to: Agenda Introduction to Servo Control Theory PID Algorithm Overview Tuning & General System Characterization Oscillation Characterization Feed-forward

More information

Multi-protocol decoder in Mini-format with 6 way NEM 651 plug

Multi-protocol decoder in Mini-format with 6 way NEM 651 plug Multi-protocol decoder 73 51 in Mini-format with 6 way NEM 651 plug For locomotives from Arnold, Bemo, Brava, Fleischmann, Kato, Roco, Tillig, Minitrix. Features 73 51 Regulated Multi-protocol decoder

More information

Continental Hydraulics Installation Manual CEM-RA-A

Continental Hydraulics Installation Manual CEM-RA-A CEM-RA-A Description: This ramp amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to either proportional directional, flow, or pressure

More information

Introduction. Example. Table of Contents

Introduction. Example. Table of Contents May-17 Application Note #5532 Positioning a Stepper Motor Using Encoder Feedback on an Axis With Non-Linear Mechanics Table of Contents Introduction...1 Example...1 Open-loop operation as baseline...2

More information

DSB810A Digital DC Servo Driver Manual V1.0

DSB810A Digital DC Servo Driver Manual V1.0 User s Manual For DSB810A Digital DC Servo Driver Version 1.0 2007 All Rights Reserved Attention: Please read this manual carefully before using the driver! The content in this manual has been carefully

More information

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2

More information

VersaMax Mixed Discrete / High-Speed Counter Module

VersaMax Mixed Discrete / High-Speed Counter Module Product Description The VersaMax Mixed Discrete High-Speed Counter (HSC) module,, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,

More information

GL102 Intelligent Temperature Controller User s Guide

GL102 Intelligent Temperature Controller User s Guide GL102 Intelligent Temperature Controller User s Guide 1 Caution Abnormal operating conditions can lead to one or more undesirable events that, in turn, could lead to injury to personnel or damage to the

More information

ScaleRCHelis.com Light Controller Users Manual

ScaleRCHelis.com Light Controller Users Manual This manual is for both the 450 and High Power light controllers. The difference between the two controllers: The 450 controller is only single input allowing the user to directly control the landing and

More information

T14MZ Software Update Function Modification Contents (Version: 1.1.0, 1.2.0)

T14MZ Software Update Function Modification Contents (Version: 1.1.0, 1.2.0) T14MZ Software Update Function Modification Contents (Version: 1.1.0, 1.2.0) 1M23N14837 Hardware setting This function is for adjusting the sticks, switches and trim characteristics. [System menu] Swash

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

Qik 2s12v10 User's Guide

Qik 2s12v10 User's Guide 1 Overview 2 Contacting Pololu 3 Connecting the Qik 3a Power and Motor Connections 3b Logic Connections 3c Included Hardware 3d Jumpers 3e Indicator LEDs and Phases of Operation 3f Board Dimensions and

More information

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control ZoneLite control unit The new Flex Connectors ZoneLite is an intelligently configurable all in one lighting control solution for many commercial lighting applications. Control can vary from ON/OFF/DIM,

More information

PID Control Technical Notes

PID Control Technical Notes PID Control Technical Notes General PID (Proportional-Integral-Derivative) control action allows the process control to accurately maintain setpoint by adjusting the control outputs. In this technical

More information

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual

More information

INSTRUCTION MANUAL. Non-Sound Decoder MX600 - MX634 and Sound Decoder MX640 - MX658 Page 1

INSTRUCTION MANUAL. Non-Sound Decoder MX600 - MX634 and Sound Decoder MX640 - MX658 Page 1 Non-Sound Decoder MX6 - MX634 and Sound Decoder MX64 - MX658 Page 1 INSTRUCTION MANUAL THIN DECODER MX6, MX6R, MX6P12 SUBMINIATURE and MINIATURE DECODER NEXT 18 - DECODER MX621, MX621N, MX621R, MX621F

More information

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3 CHAPTER MAINTENANCE AND 6 TROUBLESHOOTING In This Chapter... Maintenance and Inspection.................6 2 Monthly Inspection:..................................6 2 Annual Inspection....................................6

More information

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E User s Manual Model US1000 Digital Indicating Controller Functions 2nd Edition Introduction This instruction manual describes the functions of the US1000 Digital Indicating Controller in detail. Read

More information

Advanced Programming Mode (APM) for Maestro ELV Dimmers

Advanced Programming Mode (APM) for Maestro ELV Dimmers Advanced Programming Mode (APM) for Maestro EV Dimmers Application Note #453 evision D January 2013 Maestro Models MAEV-600 MSCEV-600M Overview The Maestro dimmer features an Advanced Programming Mode

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W L L N N on error RUN 1 2 3 4 KNX EIB 1 1 1 1 Chapter 9: Dimming actuators/control units Chapter 9:Dimming actuators/control unitsart. no.6493xxas of 10/079.2Universal dimming actuators Universal dimming

More information

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives Page 2 (68) Index Honeywell HVAC Application (Software [ALFIQ105] Ver.2.09) INDEX 1. INTRODUCTION... 3 2. CONTROL I/O... 3. HVAC APPLICATION

More information

Operation/Reference Guide NXP-CPI16. NetLinx Custom Panel Interface. Custom Panel Interfaces

Operation/Reference Guide NXP-CPI16. NetLinx Custom Panel Interface. Custom Panel Interfaces Operation/Reference Guide NXP-CPI16 NetLinx Custom Panel terface Custom Panel terfaces Last Revised: 5/18/2012 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material

More information

ServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version.

ServoDMX OPERATING MANUAL. Check your firmware version. This manual will always refer to the most recent version. ServoDMX OPERATING MANUAL Check your firmware version. This manual will always refer to the most recent version. WORK IN PROGRESS DO NOT PRINT We ll be adding to this over the next few days www.frightideas.com

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13 Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access

More information