SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SIMCO ELECTRONICS 6295 Ferris Square San Diego, CA Jeremy Cooper Phone: CALIBRATION Valid To: September 30, 2018 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations and dimensional inspections 1 : I. Dimensional Parameter/Equipment Range 4 CMC 2, 7 ( ) Comments Calipers 3 Up to 5 in (5 to 48) in ( L) µin ( L) µin Gage blocks Micrometers 3 Flatness Parallelism <0.001 in <0.001 in 12 µin 18 µin Optical parallels, & monochromatic light Linearity Up to 1 in (1 to 4) in (4 to 48) in ( L) µin + 0.6R (15 + 4L) µin + 0.6R (68 + 4L) µin + 0.6R Gage blocks Height Gages 3 Up to 5 in (5 to 36) in ( L) µin (80 + 6L) µin Gage blocks, surface plates Depth Gages 3 Linearity Up to 5 in (5 to 36) in ( L) µin + 0.6R (80 + 6L) µin + 0.6R Gage blocks, surface plates Flatness <0.001 in 11 µin Optical parallels, & monochromatic light (A2LA Cert. No ) 08/29/2016 Page 1 of 21

2 Parameter/Equipment Range 4 CMC 2, 7 ( ) Comments Pin, Plug Gages Up to 1 in ( L) µin Supermicrometer, gage blocks Digital & Dial Up to 2 in ( L) µin + 0.6R Gage blocks & surface Indicators 3 plates End Standards Up to 5 in (5 to 10) in ( L) µin ( L) µin Gage blocks, Supermicrometer Surface Plates 3 Flatness Up to 48 x 72 in 98 µin Planekator Repeatability Up to in 28 µin Repeat-o-meter Thread Plug Gages Pitch Diameter Major Diameter Up to 1 in (1 to 4) in Up to 1 in (1 to 4) in ( L) µin ( L) µin ( L) µin ( L) µin Supermicrometer, gage blocks and thread wires II. Electrical DC/Low Frequency Parameter/Equipment Range 4 CMC 2, 8 ( ) Comments DC Voltage Generate 3 (0 to 220) mv (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 10 µv/v µv 7.4 µv/v + 1 µv 7.2 µv/v µv 7.3 µv/v µv 8.4 µv/v + 80 µv 12 µv/v µv Fluke 5700A/5725A (A2LA Cert. No ) 08/29/2016 Page 2 of 21

3 Parameter/Equipment Range 4 CMC 2, 5, 6, 8, 9 ( ) Comments DC Voltage Measure 3 (0 to 100) mv (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V* 8.5 V/V V 6.0 V/V V 5.3 V/V + 1 V 10 V/V + 80 V 13 V/V V* Agilent 3458A OPT-2 *add 12(V in /1000) 2 Parts in 10 6 to all V in >100 (1000 to ) V ( to ) V 0.13 % 0.16 % Ross VD A-KB-AL & HP 34401A DC Current Generate 3 (20 to 220) µa (0.22 to 2.2) ma (2.2 to 22) ma (22 to 220) ma (0.22 to 2.2) A (2.2 to 11) A 54 µa/a + 8 na 52 µa/a + 8 na 52 µa/a na 62 µa/a µa 85 µa/a + 25 µa % µa Fluke 5700A/5725A (11 to 20.5) A % µa Fluke 5520A/SC600 Clamp Meters to 1000 A (10 to 100) A (20.5 to 1000) A 0.1 % 0.51 % A Valhalla 2555A, L&N 4361, & Agilent 3458A Fluke 5500A/coil and 5520A/SC600 DC Current Measure 3 (0.1 to 1) µa (1 to 10) µa (10 to 100) µa (0.1 to 1) ma (1 to 10) ma (10 to 100) ma (0.1 to 1) A (1 to 10) A (10 to 100) A 36 µa/a + 70 pa 24 µa/a pa 23 µa/a na 22 µa/a + 5 na 22 µa/a + 50 na 36 µa/a µa 0.01 % + 10 µa 0.06 % 0.1 % Agilent 3458A OPT-2 L&N 4361 and Agilent 3458A opt-2 (A2LA Cert. No ) 08/29/2016 Page 3 of 21

4 Parameter/Equipment Range CMC 2, 6, 8, 9 ( ) Comments Resistance Measure 3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kω (1 to 10) kω (10 to 100) kω (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1.0) GΩ 15 µω/ω + 52 µω 12 µω/ω mω 10 µω/ω mω 10 µω/ω mω 10 µω/ω + 58 mω 15 µω/ω + 2 Ω 52 µω/ω Ω % + 1 kω 0.51 % + 11 kω Agilent 3458A OPT-2 Resistance Generate 3 Fixed Points 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kω 1.9 kω 10 kω 19 kω 100 kω 190 kω 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 51 µω 98 µω/ω µω 98 µω/ω µω 30 µω/ω µω 29 µω/ω µω 18 µω/ω µω 18 µω/ω + 82 µω 14 µω/ω + 82 µω 14 µω/ω µω 13 µω/ω µω 13 µω/ω mω 13 µω/ω mω 15 µω/ω + 82 mω 21 µω/ω + 82 mω 22 µω/ω mω 47 µω/ω mω 53 µω/ω Ω % Ω Fluke 5700A (A2LA Cert. No ) 08/29/2016 Page 4 of 21

5 Parameter/Equipment Range CMC 2, 5, 9 ( ) Comments Resistance Generate 3 (cont) 4-Wire BNC 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kω 10 kω 100 kω 3.4 % 3.3 % 5.1 % 3.4 % 0.04 % 0.17 % 1.4 % HP 16074A Variable (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kω (1.1 to 3.3) kω (3.3 to 11) kω (11 to 33) kω (33 to 110) kω (110 to 330) kω (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 32 µω/ω mω 24 µω/ω mω 22 µω/ω mω 22 µω/ω mω 22 µω/ω mω 22 µω/ω + 16 mω 22 µω/ω + 17 mω 22 µω/ω mω 22 µω/ω mω 28 µω/ω Ω 28 µω/ω Ω 52 µω/ω + 24 Ω % + 39 Ω % kω % kω 0.24 % + 78 kω 1.2 % kω Fluke 5520A/SC600 (A2LA Cert. No ) 08/29/2016 Page 5 of 21

6 Parameter/Equipment Range CMC 2, 9 ( ) Comments Electrical Simulation of Thermocouples Indicating Devices Generate & Measure 3 Type E -250 C to -100 C -100 C to -25 C -25 C to 350 C 350 C to 650 C 650 C to 1000 C 0.39 C 0.14 C 0.12 C 0.14 C 0.17 C Fluke 5520A/SC600 Type J -210 C to -100 C -100 C to -30 C -30 C to 150 C 150 C to 760 C 760 C to 1200 C 0.22 C 0.14 C 0.12 C 0.14 C 0.19 C Type K -200 C to -100 C -100 C to -25 C -25 C to 120 C 120 C to 1000 C 1000 C to 1372 C 0.27 C 0.16 C 0.14 C 0.21 C 0.32 C Type T -250 C to -150 C -150 C to 0 C 0 C to 120 C 120 C to 400 C 0.50 C 0.20 C 0.14 C 0.12 C Waveform Measure 3 Amplitude (0 to 40) V Time / Frequency DC to 1 GHz DC to 1 GHz 1.7 % 120 µhz/hz Tektronix TDS684C Rise & Fall Time 350 ps to 1 s 57 ps (A2LA Cert. No ) 08/29/2016 Page 6 of 21

7 Parameter/Range 4 Frequency CMC 2, 5, 6, 9 ( ) Comments Oscilloscopes 3 Level Sine Wave (5 mv to 5.5 V) (p-p) Level Sine Flatness (5 mv to 5.5 V) (p-p) Relative to 50 khz Reference DC Signal 50, (0.01 to 10) khz 1 M, (0.01 to 10) khz 50 khz reference (0.05 to 100) MHz (100 to 300) MHz (300 to 600) MHz 1 mv to 6.6 V 1 mv to 130 V 1.6 % V 1.7 % V 2 % V 3.3 % V 0.2 % + 40 V 0.08 % + 40 V Fluke 5520A/SC600 See RF Power/Flatness generate for oscilloscopes above 600 MHz Square Wave Signal 50, (0.01 to 10) khz 1 M, (1 to 10) khz 1 mv to 6.6 V (p-p) 1 mv to 130 V (p-p) 0.2 % + 40 V 0.08 % + 40 V Time Marker Output Into 50 2 ns to 20 ms 50 ms to 5 s 2.1 µs/s ( t) µs/s t = sec Pulse Rise Time Generate Rep Rate: 1 khz to 10 MHz (125 to 350) ps 40 ps AC Current Measure 3 (5 to 100) µa (0.1 to 1) ma (45 to 1000) Hz (45 to 100) Hz (0.1 to 5) khz % + 35 na 0.07 % na % na Agilent 3458A OPT -2 (1 to 10) ma (45 to 100) Hz (0.1 to 5) khz 0.07 % µa % µa (10 to 100) ma (45 to 100) Hz (0.1 to 5) khz 0.07 % + 23 µa % + 23 µa (0.1 to 1) A (45 to 100) Hz (0.1 to 5) khz % µa 0.12 % µa (1 to 10) A (10 to 100) A (10 to 60) Hz (10 to 60) Hz % 0.15 % L & N 4361 & Agilent 3458A (A2LA Cert. No ) 08/29/2016 Page 7 of 21

8 Parameter/Range Frequency CMC 2, 5, 8, 9 ( ) Comments AC Current Generate 3 (0.22 to 2.2) ma (>40 to 1000) Hz (1 to 5) khz % + 35 na % na Fluke 5700A/5725A (2.2 to 22) ma (>40 to 1000) Hz (1 to 5) khz % na % na (22 to 220) ma (>40 to 1000) Hz (1 to 5) khz % µa % + 40 µa (0.22 to 2.2) A (>40 to 1000) Hz (1 to 5) khz % + 35 µa % + 80 µa (2.2 to 11) A (>40 to 1000) Hz (1 to 5) khz (5 to 10) khz 0.05 % µa % µa 0.36 % µa (33 to 330) µa (11 to 20.5) A (>45 to 1000) Hz (1 to 5) khz (>0.1 to 1) khz (1 to 5) khz % µa 0.23 % µa 0.12 % ma 2.3 % ma Fluke 5520A/SC600 LCOMP OFF (10 to 100) A Clamp Meters to 1000 A (20.5 to 1000) A (10 to 60) Hz (45 to 400) Hz 0.15 % 1.5 % A Valhalla 2555A, L&N 4361, & Agilent 3458A Fluke 5500A/coil & 5520A/SC600 LCOMP OFF (A2LA Cert. No ) 08/29/2016 Page 8 of 21

9 Parameter/Range Frequency CMC 2, 8, 9 ( ) Comments AC Voltage Generate 3 (0.22 to 2.2) mv (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz % µv % µv % µv % µv % + 9 µv 0.11 % + 16 µv 0.17 % + 29 µv 0.34 % + 31 µv Fluke 5700A OPT 03 & 5725A (2.2 to 22) mv (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz % + 11 µv % µv % + 12 µv % + 13 µv % + 14 µv 0.11 % + 27 µv 0.17 % + 40 µv 0.34 % + 55 µv (22 to 220) mv (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz % + 53 µv % + 23 µv % + 8 µv % + 8 µv % + 25 µv 0.15 % + 25 µv 0.18 % + 35 µv 0.4 % + 80 µv (0.22 to 2.2) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz 0.05 % µv 0.16 % µv 83 µv/v + 6 µv % + 16 µv % + 70 µv % µv 0.11 % µv 0.23 % µv (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz 0.05 % mv % mv 83 µv/v + 60 µv % µv % µv 0.05 % mv 0.13 % mv 0.31 % mv (A2LA Cert. No ) 08/29/2016 Page 9 of 21

10 Parameter/Range Frequency CMC 2, 6, 8, 9 ( ) Comments AC Voltage Generate 3 (cont) (22 to 220) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 khz (300 to 500) khz (0.5 to 1) MHz 0.05 % + 48 mv % + 17 mv 89 µv/v mv 0.02 % mv 0.05 % + 8 mv 0.15 % + 90 mv 0.47 % + 90 mv 1.2 % mv Fluke 5700A OPT 03 & 5725A Subject to 2.2 x 10 7 V Hz limitation (220 to 1100) V (40 to 1000) Hz (1 to 20) khz (20 to 30) khz 94 µv/v mv % + 6 mv % + 11 mv (250 to 750) V (30 to 50) khz % + 11 mv AC Voltage Measure 3 (1 to 10) mv (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz % µv % µv % µv 0.12 % µv 0.58 % µv 4.6 % µv Agilent 3458A OPT-2 (10 to 100) mv (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz (0.3 to 1) MHz % µv % µv % µv % µv % µv 0.35 % + 12 µv 1.2 % + 12 µv (0.1 to 1) V (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz (0.3 to 1) MHz % + 46 µv % + 23 µv % + 20 µv % + 20 µv % + 23 µv 0.35 % µv 1.2 % µv (1 to 10) V (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz (0.3 to 1) MHz % mv % mv % mv % mv % mv 0.35 % mv 1.2 % mv (A2LA Cert. No ) 08/29/2016 Page 10 of 21

11 Parameter/Range Frequency CMC 2, 6, 9 ( ) Comments AC Voltage Measure 3 (cont) (10 to 100) V (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz % mv % mv % mv % mv 0.14 % mv 0.46 % + 12 mv Agilent 3458A OPT-2 (100 to 700) V (1 to 40) Hz (40 to 1000) Hz (1 to 20) khz % + 46 mv % + 23 mv % + 23 mv 0.14 % + 23 mv 0.35 % + 23 mv (700 to ) V ( to ) V (50 to 60) Hz (50 to 60) Hz 0.59 % 0.61 % Ross VD A- KB-AL & HP 34401A Inductance Generate 3 4-Wire BNC 100 H DC to 1 khz 0.24 % HP 16074A 100 mh DC to 1 khz 0.12 % (A2LA Cert. No ) 08/29/2016 Page 11 of 21

12 Parameter/Range 4 Frequency CMC 2, 5, 9 ( ) Comments Capacitance Generate 3 2-Wire (0.19 to <3.3) nf (3.3 to <11) nf (11 to 110) nf (110 to <330) nf (0.33 to <1.1) µf (1.1 to <3.3) µf (3.3 to <11) µf (11 to <33) µf (33 to <110) µf (110 to <330) µf (0.33 to <1.1) mf (1.1 to <3.3) mf (3.3 to <11) mf (11 to <33) mf (33 to <110) mf (0.01 to 10) khz (0.01 to 1) khz (0.01 to 1) khz (0.01 to 1) khz (10 to 600) khz (10 to 300) khz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.58 % + 12 pf 0.29 % + 12 pf 0.29 % pf 0.29 % pf 0.29 % nf 0.29 % nf 0.29 % + 12 nf 0.46 % + 36 nf 0.52 % nf 0.52 % nf 0.52 % µf 0.52 % µf 0.52 % + 12 µf 0.87 % + 35 µf 1.3 % µf Fluke 5520A/SC600 4-Wire BNC 1 pf (10 to 1000) Hz (0.001 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 4) MHz (4 to 5) MHz (5 to 10) MHz (10 to 13) MHz % % % % % % 0.25 % 0.37 % HP 16380A air capacitor set, HP 16381A 10 pf (10 to 1000) Hz (0.001 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 4) MHz (4 to 5) MHz (5 to 10) MHz (10 to 13) MHz % % % % % % % 0.04 % HP 16382A (A2LA Cert. No ) 08/29/2016 Page 12 of 21

13 Parameter/Range 4 Frequency CMC 2, 9 ( ) Comments Capacitance Generate 3 (cont) 4-Wire BNC 100 pf (10 to 1000) Hz (0.001 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 4) MHz (4 to 5) MHz (5 to 10) MHz (10 to 13) MHz % % % % % % 0.06 % 0.07 % HP 16383A 1000 pf (10 to 1000) Hz (0.001 to 1) MHz (1 to 2) MHz (2 to 3) MHz (3 to 4) MHz (4 to 5) MHz (5 to 10) MHz (10 to 13) MHz 0.13 % % 0.04 % % % % 0.19 % 0.28 % HP 16384A III. Electrical RF/Microwave Parameter/Range 4 Frequency CMC 2 ( ) Comments RF Power 3 Generate ( to -4.99) dbm (-5.0 to ) dbm 200 Hz to 80 MHz db 0.13 db HP 3335A (+20 to -100) dbm 9 khz to 3200 MHz (>3200 to 4000) MHz 1.2 db 2.3 db HP 8648D OPT-1E2, 1E5, 1EA (<-100 to -127) dbm (9 to <100) khz (0.1 to 2500) MHz (>2500 to 4000) MHz 3.7 db 1.7 db 3.7 db HP 8648D OPT-1E2, 1E5, 1EA > 10 dbm (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (0.01 to <2) GHz 1.4 db 0.72 db 1.0 db 1.6 db HP 83640B OPT-001 Band 0 > 10 dbm (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (2 to 20) GHz 1.5 db 0.88 db 1.2 db 1.8 db HP 83640B OPT-001 Bands 1, 2, & 3 (A2LA Cert. No ) 08/29/2016 Page 13 of 21

14 Parameter/Range 4 Frequency CMC 2 ( ) Comments RF Power 3 Generate (cont) (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (20 to 40) GHz 1.1 db 1.4 db 2 db HP 83640B OPT-001 Bands 4, 5 & 6 RF Flatness 3 Generate (+13 to ) dbm 1 khz to 25 MHz (25 to 80) MHz db 0.18 db HP 3335A > 10 dbm (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (0.01 to <2) GHz 1.1 db 0.63 db 0.84 db 1.3 db HP 83640B OPT-001 Band 0 > 10 dbm (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (2 to 20) GHz 1.2 db 0.76 db 0.98 db 1.4 db HP 83640B OPT-001 Bands 1, 2 & 3 (9.98 to -9.98) dbm (-10 to ) dbm (-60 to -110) dbm (20 to 40) GHz 0.98 db 1.2 db 1.6 db HP 83640B OPT-001 Bands 4, 5 & 6 RF Power/Flatness 3 Generate (+20 to -20) dbm (0.3 to 1) MHz (0.001 to 4.2) GHz 0.2 db 0.19 db 0.19 db HP 8648D, 11667B, 8482A & E4419B (+20 to -50) dbm (0.05 to 10) GHz (10 to 13) GHz (13 to 26.5) GHz 0.2 db 0.25 db 0.32 db HP 83640B, 11667B, E4413A & E4419B (A2LA Cert. No ) 08/29/2016 Page 14 of 21

15 Parameter/Range 4 Frequency CMC 2, 9 ( ) Comments RF Power 3 Measure (+10 to 0) dbm (0 to -10) dbm (-10 to -20) dbm (-20 to -30 dbm (-30 to -40) dbm (-40 to -50) dbm (-50 to -60) dbm (-60 to -70) dbm (-70 to -80) dbm (-80 to -90) dbm (-90 to -100) dbm (-100 to -110) dbm (-110 to -120) dbm 2.5 MHz to 1.3 GHz 0.11 db 0.11 db 0.11 db 0.12 db 0.15 db 0.16 db 0.18 db 0.21 db 0.24 db 0.25 db 0.27 db 0.29 db 0.52 db HP 8902A & 11722A (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (1.3 to 26.5) GHz 0.10 db 0.11 db 0.11 db 0.13 db 0.15 db 0.16 db 0.18 db 0.21 db 0.23 db 0.25 db 0.27 db HP 8902A & 11792A 0 dbm 50 MHz (0.01 to 1) GHz db (0.44 %) db (0.57 %) HP 432A, 478A-H75, 34401A (+20 to -20) dbm (0.3 to 1) MHz (0.001 to 4.2) GHz db db db HP 8482A & E4419B (+20 to -50) dbm (0.05 to 10) GHz (10 to 13) GHz (13 to 26.5) GHz db db 0.12 db HP E4413A & E4419B (30 to -90) dbm 9 khz to 2.9 GHz (2.9 to 6.46) GHz (6.46 to 13.2) GHz (13.2 to 22) GHz (22 to 26.8) GHz (26.8 to 31.15) GHz 1.2 db 2.1 db 3.2 db 4.1 db 4.6 db 3.5 db HP 8564E (30 to -90) dbm (31.15 to 40) GHz 3.7 db (A2LA Cert. No ) 08/29/2016 Page 15 of 21

16 Parameter/Range 4 Frequency CMC 2 ( ) Comments RF Attenuation 3 Measure (0 to -10) db (-10 to -20) db (-20 to -30) db (-30 to -40) db (-40 to -50) db (-50 to -60) db (-60 to -70) db (-70 to -80) db (-80 to -90) db (-90 to -100) db (-100 to -110) db 2.5 MHz to 1.3 GHz db db db db 0.12 db 0.14 db 0.16 db 0.20 db 0.22 db 0.24 db 0.33 db HP 8902A & 11722A (0 to -10) db (-10 to -20) db (-20 to -30) db (-30 to -40) db (-40 to -50) db (-50 to -60) db (-60 to -70) db (-70 to -80) db (-80 to -90) db (-90 to -100) db (1.3 to 26.5) GHz db db db 0.10 db 0.13 db 0.15 db 0.17 db 0.20 db 0.23 db 0.33 db HP 8902A & 11792A (0 to -25) db (0.3 to 1) MHz (0.001 to 4.2) GHz db db db HP 8482A & E4419B (0 to -50) db (0.05 to 10) GHz (10 to 13) GHz (13 to 26.5) GHz db db db HP E4413A & E4419B (0 to -120) db 9 khz to 2.9 GHz (2.9 to 6.46) GHz (6.46 to 13.2) GHz (13.2 to 22) GHz (22 to 26.8) GHz (26.8 to 31.15) GHz 0.93 db 1.6 db 2.5 db 2.9 db 2.5 db 3.4 db HP 8564E (0 to -115) db (31.15 to 40) GHz 2.8 db (A2LA Cert. No ) 08/29/2016 Page 16 of 21

17 Parameter/Range Frequency CMC 2, 7, 9 ( ) Comments Distortion 3 Measure -80 db -65 db 20 Hz to 20 khz (20 to 100) khz 1.2 db 2.3 db HP 8903B Amplitude Modulation 3 Measure Depth: (5 to 99) % Rate: (0.05 to 10) khz Depth: (5 to 99) % Rate: (0.02 to 10) khz (0.15 to 10) MHz 2.1 % + 1.0R 3.0 % + 1.0R HP 8902A & 11722A Depth: (5 to 99) % Rate: (0.05 to 50) khz Depth: (5 to 99) % Rate: (0.02 to 100) khz (0.01 to 1.3) GHz 1.1 % + 1.0R 3.0 % + 1.0R Depth: (5 to 99) % Rate: (0.05 to 50) khz Depth: (5 to 99) % Rate: (0.02 to 100) khz (1.3 to 26.5) GHz 1.6 % + 1.0R 3.0 % + 1.0R HP 8902 & 11792A Frequency Modulation 3 Measure Deviation: <40 khz/pk Rate: (0.02 to 10) khz (0.25 to 10) MHz 2.3 % + 1.3R HP 8902A & 11722A Deviation: <400 khz/pk Rate: (0.05 to 100) khz (0.01 to 26.5) GHz 1.2 % + 1.3R HP8902A, 11772A & 11792A Deviation: <400 khz/pk Rate: (0.05 to 200) khz (0.01 to 26.5) GHz 5.8 % + 1.3R Phase Modulation 3 Measure Rate: (0.2 to 10) khz (0.15 to 10) MHz 4 % Rad HP 8902A & 11722A Rate: (0.02 to 200) khz (0.01 to 26.5) GHz 5 % Rad HP 8902A & 11792A (A2LA Cert. No ) 08/29/2016 Page 17 of 21

18 IV. Mechanical Parameter/Equipment Range CMC 2, 7, 9 ( ) Comments Scales & Balances 3 (1 to 500) mg (1 to 5) g (5 to 10) g (10 to 20) g (20 to 200) g (0.2 to 10) kg (10 to 20) kg (20 to 35) kg mg R mg R mg R mg R % R % R 84 mg R 89 mg R Troemner Ultra Class & Class 1 weights (0 to 500) lb % R Class F weights Torque Measure (5 to 50) in ozf (1 to 10) in lbf (10 to 50) in lbf (50 to 250) in lbf (25 to 250) ft lbf (250 to 500) ft lbf (500 to 1000) ft lbf 0.75 % R 0.6 % R 0.65 % R 0.61 % R 0.71 % R 0.72 % R 5.8 ft lbf R AWS torque system Mountz torque system Torque Measure 3 (5 to 50) in ozf (1 to 10) in lbf (10 to 50) in lbf (50 to 250) in lbf 0.75 % R 0.6 % R 0.65 % R 0.61 % R AWS torque system Mountz torque system Torque Measuring (0 to 250) in lbf 0.12 % R Class F weights & Equipment 3 torque wheels Force 3 Measuring Equipment (0 to 300) lbf % R Class F weights Pressure & Vacuum Measuring Equipment & Measure (0.9 to 3.16) psia (3.16 to 7.53) psia (7.53 to 23) psia (23 to 97) psia (97 to 300) psia psia R % R % R psia R 0.01 % R Fluke PPC4 (-14.7 to -12.3) psig (-12.3 to -7.9) psig (-7.9 to 8) psig (8 to 86.7) psig (86.7 to 300) psig psig R % R % R psig R % R (2 to ) psi % R Pressurements M P (A2LA Cert. No ) 08/29/2016 Page 18 of 21

19 Parameter/Equipment Range CMC 2, 7, 9 ( ) Comments Pressure & Vacuum Measuring Equipment & Measure 3 (-14.7 to 300) psig (300 to 1000) psig (1000 to ) psig 0.18 psig R 1.2 psig R 7.3 psig R Druck PM620 Druck DPI705 RPM Measure 3 (0 to ) rpm % R Monarch PLT200 V. Thermodynamic Parameter/Equipment Range CMC 2, 7, 9 ( ) Comments Temperature Measuring Equipment (-70 to 175) o C o C R Hart Scientific 1502A, 5628 w/temperature sources Temperature Measuring Equipment 3 (-5 to 125) o C (-15 to 350) o C o C R 0.12 o C R Hart Scientific 1502A, 5628 w/temperature sources Temperature Measure 3 (-196 to 0) o C (0 to 100) o C (100 to 350) o C (350 to 660) o C o C R o C R o C R o C R Hart Scientific 1502A, 5628 Infrared Temperature Measuring Equipment 3, 10 (25 to 100) o C (100 to 300) o C (300 to 500) o C 0.61 o C % 0.78 o C % 1 o C % Hart Scientific 9132 λ = (8 to 14) µm Ɛ = 0.95 Relative Humidity Measure & Measuring Equipment 3 (1 to 90) % RH (90 to 99) % RH 1.4 % RH 2.3 % RH Vaisala HMI41/HPM46, MI70/HMP76 w/humidity chamber (A2LA Cert. No ) 08/29/2016 Page 19 of 21

20 VI. Time & Frequency Parameter/Range Frequency CMC 2 ( ) Comments Timers & Stopwatches 3 Up to 24 hours 65 ms HP 53132A, HP 33220A phase locked to GPS Frequency Reference 10 MHz 1.7 phz/hz Fluke 910R GPS Frequency Measuring Equipment Hz to 600 MHz 86 phz/hz + 5 µhz Fluke 5520A phase locked to GPS 9 khz to 4 GHz 86 phz/hz HP 8648D phase locked to GPS (0.01 to 40) GHz 86 phz/hz HP 83640B phase locked to GPS Frequency 3 Measure 0.1 Hz to 3 GHz 86 phz/hz + 5 µhz Fluke GPS & HP 53132A phase locked to GPS 10 Hz to 26.5 GHz 0.58 nhz/hz Fluke GPS & HP 5343A phase locked to GPS (26.5 to 40) GHz 1.1 nhz/hz Fluke GPS & HP 8564E phase locked to GPS Tachometers (60 to ) rpm 0.18 mrpm/rpm R HP 33220A phase locked to GPS 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. (A2LA Cert. No ) 08/29/2016 Page 20 of 21

21 4 Where ranges are not specified, the CMC stated is for the cardinal points only. Other values can be obtained using substitution method with uncertainty increased by a multiple for each substitution. 5 Based on using the standard at the temperature the Fluke 5520A with SC600 was calibrated (tcal ± 5 o C) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 o C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 o C of use. For AC Current, CMC are determined with LCOMP Off. CMC is based upon 1-year specifications and is read as ppm (parts per million) or percent output plus floor specification where defined. 6 Based on using the standard at the temperature the Agilent 3458A was calibrated (tcal ± 5 o C) and an auto-calibration (ACAL) was performed within the previous 24 hours (± 1 o C of ambient temperature). CMC is based upon 1-year specifications and is read as ppm (parts per million) or percent output plus floor specification where defined. 7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is the numerical value of the resolution of the device. 8 Based on using the Fluke 5700A/5725A within 5 o C of the temperature noted at the time of cal (tcal ± 5 o C) and assuming the zero calibration is performed every 30 days. CMC is based upon 1-year specifications and is read as ppm (parts per million, V/V) or percent of output plus floor specification where defined. Includes stability. Resistance specifications apply only to the displayed resistance value using 4-wire configuration (except for 100 MΩ). Uncertainty specifications for 220 ma and 2.2 ma ranges are increased by a factor of 1.3 when supplied through 5725A terminals. 9 When percent (%) is present in the statement of CMC; the value is defined as the percentage of reading unless otherwise noted. 10 Target Emissivity is not calibrated and assumed to be 0.95 (±0.02 from 8 to 14 µm) for Blackbody. (A2LA Cert. No ) 08/29/2016 Page 21 of 21

22 Accredited Laboratory A2LA has accredited SIMCO ELECTRONICS San Diego, CA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSLI Z and the requirements of ANSI/NCSLI Z and R205 Specific Requirements Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 29 th day of August Senior Director of Quality and Communications For the Accreditation Council Certificate Number Valid to September 30, 2018 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 6295 Ferris Square San Diego, CA 92121 Jeremy Cooper Phone: 858 200 7027 CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SIMCO SCIENTIFIC INSTRUMENT REPAIR AND CALIBRATION SERVICES CO., LTD. Flat 404 North Software Tower, NanSha IT Park Panyu NanSha, Guangzhou,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 INSTRUMENT CALIBRATION SERVICE, INC., A TEST EQUIPMENT REPAIR CORPORATION company 5965 Shiloh Road East Alpharetta, GA 30005 Don Petersen

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 9902 East 43 RD Street Suite D Tulsa, OK 74146 Mark Jackson Phone: 800 438 8165 CALIBRATION Valid To: September 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 SIMCO ELECTRONICS (Ireland) Limited IDA Business & Technology Park Garrycastle, Dublin Rd Athlone Westmeath, Ireland

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TEKTRONIX CANADA 400 Britannia Road E, Unit 2 Mississauga, Ontario L4Z 1X9 Canada Andrew Sweeny Phone: 905 241 3021 CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone: 613 226 7920 CALIBRATION Valid To: September 30, 2018 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 WESCAN CALIBRATION #9-12240 Horseshoe Way Richmond, B.C., V7A 4X9, Canada Malcolm Smith Phone: 604 275 0600

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: October

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONNECTICUT CALIBRATION LABS 327 S. Main Street Newtown, CT 06470 Joseph Zeolla Phone: 203 270 1263 CALIBRATION Valid To: October 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INSTRUMENTATION DYNATHERM INC. 4127 Rue Cousens Ville St-Laurent, QC Canada H4S 1V6 Graziano Chila Phone: 514 636 7800 CALIBRATION Valid To: May 31, 2018 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: October

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CASCADE ENGINEERING SERVICES, INC. 6640 185th Ave NE Redmond WA 98052 Contact: Charles Heidlage Phone: 425 895 8617 x 713 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PYLON ELECTRONICS INC. 147 Colonnade Road Ottawa, Ontario Canada K2E 7L9 Jim Mullins Phone: 613 226 7920 CALIBRATION Valid To: September 30, 2020 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 SIMCO ELECTRONICS 19804 Nordhoff Place Chatsworth, CA 91311 Randy Ford Phone: 818 773 9750 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 TRESCAL, INC. 5965 Shiloh Road East Alpharetta, GA 30005 Don Petersen Phone: 678 341 6090 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 AMERICAN GAGE 1131 S. Richfield Rd Placentia, CA 92870 Roger Arnold Phone: 657 216 2600 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EXPHIL CALIBRATION LABS, INC. 415 Central Avenue Bohemia, NY 11716 Steven Pidd Phone: 631 563 3520 CALIBRATION Valid To: October 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 EXPHIL CALIBRATION LABS, INC. 415 Central Avenue Bohemia, NY 11716 Steven Pidd Phone: 631 563 3520 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 SIMCO ELECTRONICS 19804 Nordhoff Place Chatsworth, CA 91311 Jim Morrissey Phone: 818 773 9750 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 GRAND RAPIDS METROLOGY 4215 Stafford Avenue, SW Grand Rapids, MI 49548 Dave Warner Phone: 616 538 7080 CALIBRATION Valid To: December

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AMERICAN GAGE 1131 S. Richfield Rd Placentia, CA Roger Arnold Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AMERICAN GAGE 1131 S. Richfield Rd Placentia, CA Roger Arnold Phone: CALIBRATION SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMERICAN GAGE 1131 S. Richfield Rd Placentia, CA 92870 Roger Arnold Phone: 657 216 2600 CALIBRATION Valid To: December 31, 2017 Certificate Number: 4296.01

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION Valid To: May 31, 2019

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 8203-J Piedmont Triad Parkway Greensboro, NC 27409 Gene Denmark Phone: 336 605 1665 Fax: 336

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS - DRAPER, UTAH 65 E. Wadsworth Park Drive Suite 101 Draper, UT 84020 Curtis Keller Phone:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 INDUSTRIAL PROCESS MEASUREMENT, INC. 3910 Park Avenue, Unit 7 Edison, NJ 08820 Mark Gural Phone: 732 632 6400 www.instrumentation2000.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 6125-C Heritage Park Drive Chattanooga, TN 37416 Connie Foster Phone: 800 327 7727 or 423 899 5801 CALIBRATION Valid To: May 31, 2019

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TEKTRONIX INC. 8020 Southpark Circle, Suite 300 Littleton, CO 80120 William Gottbreht Phone: 303 539 1400 CALIBRATION Valid To: September

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 G.T. MICHELLI COMPANY, INC. 130 Brookhollow Esplanade Harahan, LA 70123 Patrick Jester Phone: 504 733 9822 CALIBRATION Valid To: May

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 HAYES INSTRUMENT SERVICE, INC. 530 Boston Road Billerica, MA 01821 Tony Ganchi Phone: 978 663 4800 CALIBRATION Valid until: January

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 INCAL TECHNOLOGIES, INC. 3870 E. Washington Road Saginaw, MI 48601 Rob VanBuskirk Phone: 989 758 0950 CALIBRATION Valid To: May 31,

More information

President For the Accreditation Council Certificate Number Valid to January 31, 2010

President For the Accreditation Council Certificate Number Valid to January 31, 2010 A2LA has accredited THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY HAYES INSTRUMENT SERVICE, INC. Billerica, MA for technical competence in the field of Calibration This laboratory

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ENI Labs 3120 Independence Dr. Fort Wayne, IN 46808 Andrew Burd Phone: 260 471 6775 CALIBRATION Valid To: April 30, 2018 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z540-1-1994 NATIONAL TECHNICAL SYSTEMS (NTS) 7800 Highway 20 West Huntsville, AL 35806 Rick Davis Phone: 256 716 4483 CALIBRATION Valid To: December

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONTROL AUTOMATION TECHNOLOGIES CORP 6540 Emmaus Church Road Suite 106 Providence Forge, VA 23140 Rob Igoe Phone: 336 725 6120 Ext 2

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 INSTRUMENT CALIBRATION SOLUTIONS, INC. 413 Hopewell Avenue Aliquippa, PA 15001 Mr. David Beier Phone: 724 846 0136 CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALABAMA SCALE & INSTRUMENT, INC. d.b.a. ASI Calibration Labs Alabama 1644 Varner Drive Mobile, AL 36693 Lawson Hill Phone: 251 660 9999

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 7103 Juniper Road Fairview, TN Connie Foster Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 7103 Juniper Road Fairview, TN Connie Foster Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 7103 Juniper Road Fairview, TN 37062 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: May 31, 2019 Certificate Number: 1741.08

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 WESTERN STATES CALIBRATION 105 West 2950 South Salt Lake City, UT 84115-3433 Lon Miles Phone: 801 466 1700 CALIBRATION Valid To: February

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 APTIV CONTRACT SERVICES. S. DE R. L. DE C. V. CALIBRATION LAB Mexico Technical Center Ave. Hermanos Escobar #5756 Cd. Juarez, Chihuahua C.P. 32310, Mexico Ricardo

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan, GA 30265 Van Puymbrouck Phone: 770 254 0400 x 5021 CALIBRATION Valid To: December

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 ACUCAL INC. 600 South 56th Street Chandler, AZ 85226 Thomas Efaw Phone: 480 753 7000 CALIBRATION Valid To: September

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 QUALITY SYSTEMS LAB, INC. 7604 North West 6 th Ave Boca Raton, FL 33487 Bryan Wilkerson Phone: 561-999-1896 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELECTRO LAB SERVICES, INC. 517 N. Fulton Avenue Evansville, IN 47710 Robert J. Dreier Phone: 812 423 5211 CALIBRATION Valid To: April 30, 2019 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NOVASTAR METROLOGY 35200 Plymouth Road Livonia, MI 48150 Guy Howe Phone: 734 453 8003 CALIBRATION Valid To: March 31, 2019 Certificate

More information

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013)

CERTIFICATE OF ACCREDITATION. ANSI/NCSL Z (R2002) and ANSI/NCSL Z (R2013) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration 5909 Breckenridge

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PRIMARY INSTRUMENTS, INC. 9553 Vassar Avenue Chatsworth, CA 91311 Abner de Leon Phone: 818 993 4971 CALIBRATION Valid To: September

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ADVANCED TEST EQUIPMENT CORP. 10401 Roselle Street San Diego, CA 92121 Gabriel Alcala Phone: 858 558 6500 CALIBRATION Valid To: April

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JM TEST SYSTEMS, INC. Calibration Laboratory Division 1600 Watterberg Way Alexandria, LA 71303 Jerry Kraus Phone: 225 925 2029 x 3028

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 J. A. KING & COMPANY, LLC 14200 South Lakes Drive Charlotte, NC 28273 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: August

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Total Solutions, Inc. 7722 Metric Drive Mentor,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAL-TEC, INC. 114 Thruway Park Road Broussard, LA 70518 Chris Grevemberg Phone: 337 839 0450 Email: lab@caltecinc.com CALIBRATION Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SIMCO ELECTRONICS 7730B Trinity Road Suite 130 Cordova, TN 38018 Jeff Coddington Phone: 901-624-7448 CALIBRATION Valid to: September

More information

Accredited Laboratory

Accredited Laboratory Accredited Laboratory A2LA has accredited NORTHSTAR CALIBRATION, INC. Owatonna, MN for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JM TEST SYSTEMS, INC. Calibration Laboratory Division 7323 Tom Drive Baton Rouge, LA 70806 Jerry Kraus Phone: 225 925 2029 x3028 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ADVANCED TECHNOLOGY SERVICES 8201 N. University St. Peoria, IL 61615 Michael White Phone: 309 693 6052 CALIBRATION Valid to: March 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JM TEST SYSTEMS, INC. 3947 Lincoln Ave., Ste. B Groves, TX 77619 Jerry Kraus Phone: 432 580 7040 CALIBRATION Valid To: February 29,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PROBATA CORPORATION 14600 Metro Plaza Blvd. Edmond, Oklahoma 73013 Greg Chambers Phone: 405 607 4813 CALIBRATION Valid To: September

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 TRESCAL, INC. 1125 North Corporate Drive, Suite 207-A Mobile, AL 36607 Sergey Pasechnikov Phone: 251-461-6609

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NOVASTAR METROLOGY 35200 Plymouth Road Livonia, MI 48150 Guy Howe Phone: 734 453-8003 CALIBRATION Valid To: July 31, 2017 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 NORTHROP GRUMMAN MISSION SYSTEMS/BWI CALIBRATION LAB 1745A West Nursery Road Linthicum, MD 21090 Gary R. Mote

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC South Lakes Drive Charlotte, NC Connie Foster Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC South Lakes Drive Charlotte, NC Connie Foster Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC 14200 South Lakes Drive Charlotte, NC 28273 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: August 31, 2019 Certificate Number:

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Technical Maintenance, Inc. 4613 Northwest

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. J. A. KING 354 Riverchase Way Lexington, SC Connie Foster Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. J. A. KING 354 Riverchase Way Lexington, SC Connie Foster Phone: CALIBRATION SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 J. A. KING 354 Riverchase Way Lexington, SC 29072 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: February 28, 2021 Certificate Number: 1741.12 In recognition

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 TESTEQUITY LLC 6100 Condor Drive Moorpark, CA 93021 Ed Yankajtis Phone: 805 498 9933 CALIBRATION Valid To: October

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 8023 Interstate 30 Little Rock, AR 72209 Dustin R. Detten Phone: 214 638 1808 CALIBRATION Valid To: September 30, 2018

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SdM AEROSPACE PYROMETRY CALIBRATION SERVICES Avenida Tecnologico # 5754 Colonia del Real Cd Juarez Chihuahua, Mexico CP 32690 Victor

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Transcat Denver 3521 Lewiston St, Suite 12

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & Z540.3-2006 INSPEC, INC. 7282 Haggerty Rd Canton, MI 48187 Dale Robenault Phone: 734 451 8740 CALIBRATION Valid To: September 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PROCESS INSTRUMENTS, INC. 615 E Carson Street Pittsburgh, PA 15203 Karl W. Klevens Phone: 412 431 4600 website: www.procinst.com CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METROCAL, INC 3631 44 th Street SE, Suite B Kentwood, MI 49512 Kent Anderson Phone: 616 698 3124 CALIBRATION Valid To: September 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EAGLE EYE CALIBRATION LABS, INC. 21358 Nordhoff Street, Suite 101 Chatsworth, CA 91311 Kirpal Chhokar Phone: 818 993 0055 CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 Caliber Test & ment 2100 W. 6th Ave. Broomfield, CO 80020 Everett Hedrick Phone: 303 469 5335 CALIBRATION Valid to: May 31, 2019 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EL AL STANDARDS LABORATORY EL AL Head Office Ben-Gurion Airport Motty Shai Phone: 972 3 9716596 CALIBRATION Valid To: July 31, 2019 Certificate Number: 4282.01

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Techmaster Electronics, Inc. 46782 Lakeview

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 PRATT & WHITNEY CALIBRATION SERVICES LAB 17900 Beeline Highway MS 724-14 Jupiter, FL 33478 Contact: Mr. Jack Pardue Phone: 561 796 1315

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Technical Maintenance, Inc. 3000 Northwoods

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Korea 775 Gyeongin-ro

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TEKTRONIX SERVICE SOLUTIONS 24301 Catherine Industrial Road, Suite 116 Novi, MI 48375 Lance Rieger Phone: 248 305 5200 CALIBRATION Valid

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI National Accreditation Board 11617 Coldwater Road, Fort Wayne, IN 46845 USA This is to certify that E2b Calibration, LLC 521 Fifth Avenue Chardon, OH 44024 has been assessed

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 MTS METROLOGY AND CALIBRATION LABORATORY 14000 Technology Drive Eden Prairie, MN 55344 Kevin Rust Phone: 952 937 4790 www.mts.com CALIBRATION

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TEKTRONIX INC. 18939 120 th Ave NE Bothell, WA 98011 Andree Black Phone: 800 438 8165 CALIBRATION Valid To: June 30, 2018 Certificate

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that TesCom 2600 Longhorn Blvd., Ste. 112 Austin,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TEKTRONIX 9639 Interocean Drive Cincinnati, OH 45246 Richard Morton Phone: 513 870 4714 CALIBRATION Valid To: June 30, 2019 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & Z540.3-2006 INSPEC, INC. 7282 Haggerty Rd Canton, MI 48187 Thomas Snyder Phone: 734 451 8740 CALIBRATION Valid To: July 31, 2019 Certificate

More information

CALIBRATION CMC 2, 4 ( )

CALIBRATION CMC 2, 4 ( ) SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ADVANCED TEST EQUIPMENT CORP.. 104011 Roselle Street San Diego, CA 92121 Jill Berg Phone: 858 558 6500 CALIBRATION Valid To: April 30,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 TRANE LA CROSSE METROLOGY LAB 2313 20th Street South La Crosse, WI 54601 Rick McKenzie Phone: 608 787 4032 CALIBRATION Valid To: October

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ENVIROCAL INC. 256 E. Washington Street Sabina, OH 45169 Brian K. Riddick Phone: 937 584 4848 CALIBRATION Valid To: June 30, 2019 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY TESTING SERVICES, INC. 2305 Millpark Drive Maryland Heights, MO 63043 Heather Ryan Phone: 314 770 0607 CALIBRATION Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NORTHSTAR CALIBRATION, INC th Place NW Owatonna, MN John Moorhouse Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NORTHSTAR CALIBRATION, INC th Place NW Owatonna, MN John Moorhouse Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NORTHSTAR CALIBRATION, INC. 1045 26th Place NW Owatonna, MN 55060 John Moorhouse Phone: 507 444 9111 CALIBRATION Valid To: February 29, 2020 Certificate Number:

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that TECHMASTER ASIA (Thailand) Co., Ltd 5/41

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 DIGITAL MEASUREMENT METROLOGY INC. (A TRESCAL COMPANY) 26 Automatic Road, Unit 4 Brampton, Ontario, CANADA L6S 5N7 Nana Mantey Phone:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JOHNSON GAGE AND INSPECTION 5920 W. 21st Street North Wichita, KS 67205 Scott Porter Phone: 316-943-7532 CALIBRATION Valid To: May 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 MENTOR TECHNICAL GROUP METROLOGY LAB Caguas Real #100 Alhambra Granada Blvd. Caguas, Puerto Rico Angel Pabellon Phone: 787 536-6028

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Caltronix, Inc. 100 Town Centre Drive Rochester,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 INTERNATIONAL CERTIFICATION MEASUREMENTS, INC. (SUBSIDIARY OF LEADER CORPORATION) 51644 Filomena Dr. Shelby Township, MI 48315 Brenda

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Transcat Portland 14058 SW Milton Court Portland,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CONTROL AUTOMATION TECHNOLOGIES CORP 101 N Chestnut St. Winston-Salem, NC 27101 Rob Igoe Phone: 336 725 6020 x 111 CALIBRATION Valid

More information

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002) CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that McCune s Instrument, Inc. 108 North Lee Street

More information