NOISE MEASUREMENTS AND RECORD OF THE ZERO LEVEL NOISE MEASUREMENTS REPORT

Size: px
Start display at page:

Download "NOISE MEASUREMENTS AND RECORD OF THE ZERO LEVEL NOISE MEASUREMENTS REPORT"

Transcription

1 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL OISE MEASUREMETS REPORT 1

2 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL TABLE OF COTETS OISE MEASUREMET REPORT PRESETATIO 1. OISE MEASUREMETS AREAS 2. OISE MEASURMET FORMS 3. PRESETATIO OF MEASUREMET 4. COMMETAR OF THE APPEDIX: oise Forms. 2

3 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL 1. OISE MEASUREMETS AREAS Generally In order to measure the acoustic environment at critical areas of the project Construction of new motorway section Demir Kapija Smokvica as part of the Pan-European Corridor X, a noise monitoring and measuring program was implemented during the phase before construction s period. The noise monitoring program was implemented as part of AKTOR S company obligations, as required from project s contract Construction of new motorway section Demir Kapija Smokvica as part of the Pan-European Corridor X and from the Environmental Impact Assessment Study - Update (July 2009). Aim of program s application and of the acoustic environment - noise measurements, before the implementation of the Project Motorway, is the submission of the elements to the Independent Engineer - Environmental Agency - Supervision. Furthermore, aim of the noise measurements is to create a data base of the zero level acoustic background and some possible use of the results to the countermeasures planning against noise in case of fauna s birds nuisance and local population. Within this context, measurements and recordings of the acoustic environment were completed at the points that are presented in the following Table. TABLE 1: oise measurements points ΑΑ AREA 1 Demir Kapija Canyon 2 Demir Kapija Gorge 3 Miravci 4 Smokvica 5 Miletkovo 6 South Portal of Tunnel 1 oise measurements were done on the axis of the existing motorway inside Demir Kapija Canyon, in the area of South Portal of Tunnel T1 and inside Demir Kapija Gorge which is the protection area for vultures. oise s were made also in residential areas neighboring the project as Miravci, Smokvica and Miletkovo. The measurements for the recordings of the acoustic environment were completed during the period from to , a period when the breeding season begins. During the acoustic environment measurements, no construction activities were being performed, but the traffic circulation at the existing road was flowing normally. Repetition of measurements was executed in order to cover different weather conditions. The program was implemented according to the ational and the International Legislation, as well as relevant standards regarding noise-acoustic environment: 3

4 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL The Law on Prevention of Harmful oise Impact (The Official Gazette of SRM o. 21/84) Guidelines for Community oise, World Health Organization, Geneva, Project s Environmental Impact Assessment Study Update, July ISO :1996 Acoustics Attenuation of sound during propagation outdoors Part 2: General Method of Calculation, International Organization for the Standardization, BS :2009 Code of practice for noise and vibration control on construction and open sites. oise, British Standards Institute, December 2008 oise Data According to World Health Organization s 1999 Guidelines, LAeq (at a given period T) should be used to measure continuing sounds such as road, many types of industrial noises (including construction noise) and noise from ventilation systems in buildings. When there are distinct events to the noise such as with aircraft or railway noise, measures of the individual events should be obtained (using, for example, LAmax), in addition to LAeq,T measurements. The necessary definitions for the noise measurements are the following: L Aeq (Equivalent Continuous A-weighted Sound Pressure Level): The value of the A- weighted sound pressure level of a continuous, steady sound that, within a specified time interval T, has the same mean square sound pressure as a sound under consideration whose level varies over time. L Amax (maximum sound level): The highest value of the A-weighted sound pressure level that occurs during a given event or time period. The time weighting should be specified. L Amax (minimum sound level): The lowest value of the A-weighted sound pressure level that occurs during a given event or time period. The time weighting should be specified. T (time period in seconds or minutes): A specified time interval equal to the noise measurement duration. SPL (Sound pressure level or sound level) is a logarithmic measure of the effective sound pressure of a sound relative to a reference value. It is measured in decibels (db) above a standard reference level. The commonly used "zero" reference sound pressure in air or other gases is 20 μpa RMS, which is usually considered the threshold of human hearing (at 1 khz). A-weighting is the most commonly used of a family of curves defined in the International standard IEC 61672:2003 and various national standards relating to the measurement of sound pressure level. A-weighting is applied to instrument-measured sound levels in effort to account for the relative loudness perceived by the human ear, as the ear is less sensitive to low audio frequencies. 4

5 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL The data and the indicators mentioned above for the 6 selected points of noise measurements are presented in detail and are commented below. oise record, in 5-minutes base, was performed by mobile noise equipment, equipped with noise-meter, all-weather microphone and are being presented on the Table 2 of the present report. During noise recording the noise meter CASTLE PRO-DX Vocis of Castle Group Ltd Company was mainly used. Before the acoustic measurement, the calibration of the equipment took place with specific calibration device (acoustical calibrator) type GA607 designed by the same company, in order to succeed the reliability of results during the recording period of the acoustic environment. For completed noise measurements, local data conditions were recorded as well, data that are useful for the evaluation of the results. The recorded data also include data for device s calibrations, measurements manager, weather conditions, photographic record of the area Google earth and points of sound measurements and other specific descriptions of conditions. Each measurement of has a duration of 5 or 10 minutes. The sound measurements that took place, fully cover the area of Demir Kapija Gorge and Demir Kapija Canyon, while a complete file with all primary data of noise sound measurements is being kept. s have been made by the environmental expert Michalis Karasoulas and worksite s Environmental Manager Periklis Andris, by the presence of environmental expert of Engineer Mr Aldo Contellacci and AKTOR s Sustainable Development Manager Dr.-Ing. iki Siouta. 2. OISE MEASURMET FORMS In this chapter the results are presented in specific forms, as previously mentioned. The general data of each measurement are presented inside the form i.e. location, photograph of the area building, measurement manager, weather conditions etc. as well as the recorded-treated with the use of software, noise data of Leq (5 min) and the variance chart with the allowable noise limits. Comments and conclusions of the noise monitoring program are mentioned in chapter 3 that follows. All the forms constitute Appendix I. 5

6 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL 3. PRESETATIO OF MEASUREMET umber Table 2: oise measurements of period Location X//Z Demir Kapija Canyon X: : Z:159 Demir Kapija Gorge X: : Z: Demir Kapija Gorge 04 Demir Kapija Canyon Miravci X: : Z:103 Smokvica X: : Z:95 Miletkovo X: : Z:94 08 Smokvica 09 Miletkovo 10 Miravci 11 South Portal T1 X: : Z: South Portal T1 13 Smokvica 14 Miletkovo 15 Miravci 16 South Portal T1 17 Demir Kapija Gorge 18 Demir Kapija Canyon Date/Period / / / / / / / / / / / / / / / / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 66,0 86,0 42,9 DKC1 82,2 98,1 68,4 CA2 74,0 90,1 61,4 CA3 46,3 60,5 39,1 DKC4 55,7 76,1 38,3 MIR1 48,0 79,3 34,9 SMO1 46,2 75,0 37,5 MIL1 50,4 75,6 37,0 SMO2 42,9 64,3 37,6 MIL2 58,3 84,0 39,9 MIR2 71,7 90,1 49,3 SPT11 58,0 69,3 44,9 SPT12 48,4 64,1 36,9 SMO3 51,7 66,6 38,3 MIL3 60,7 80,2 44,2 MIR3 63,2 76,2 53,0 SPT13 79,8 85,5 72,5 GOR3 56,9 82,7 40,0 CA1 Comments Trucks passed Highway inside gorge, traffic Highway inside gorge, traffic o trucks passed Local Highway Highway inside gorge, traffic Trucks passed Weather s,,,,, / 6

7 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL umber 02 Location X//Z Demir Kapija Gorge X: : Z: Demir Kapija Gorge 17 Demir Kapija Gorge Table 3: oise measurements at Demir Kapija Gorge Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 82,2 98,1 68,4 CA2 74,0 90,1 61,4 CA3 79,8 85,5 72,5 GOR3 Comments Highway inside gorge, traffic Highway inside gorge, traffic Highway inside gorge, traffic Weather s,, umber 01 Table 4: oise measurements at Demir Kapija Canyon Location X//Z Demir Kapija Canyon X: : Z: Demir Kapija Canyon 18 Demir Kapija Canyon Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 66,0 86,0 42,9 DKC1 46,3 60,5 39,1 DKC4 56,9 82,7 40,0 CA1 Comments Trucks passed o trucks passed Trucks passed Weather s,,, Table 5: oise measurements at Miravci umber 05 Location X//Z Miravci X: : Z: Miravci 15 Miravci Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 55,7 76,1 38,3 MIR1 58,3 84,0 39,9 MIR2 60,7 80,2 44,2 MIR3 Comments Local Weather s Table 6: oise measurements at Smokvica umber 06 Location X//Z Smokvica X: : Z:95 08 Smokvica 13 Smokvica Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 48,0 79,3 34,9 SMO1 50,4 75,6 37,0 SMO2 48,4 64,1 36,9 SMO3 Comments Weather s 7

8 OISE MEASUREMETS AD RECORD OF THE ZERO LEVEL Table 7: oise measurements at Miletkovo umber 07 Location X//Z Miletkovo X: : Z:94 09 Miletkovo 14 Miletkovo Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 46,2 75,0 37,5 MIL1 42,9 64,3 37,6 MIL2 51,7 66,6 38,3 MIL3 Comments Weather s umber 11 Table 8: oise measurements at South Portal of Tunnel T1 Location X//Z South Portal T1 X: : Z: South Portal T1 16 South Portal T1 Date/Period / / / Leq(A) Lmax(A) Lmin(A) Meas. Code 71,7 90,1 49,3 SPT11 58,0 69,3 44,9 SPT12 63,2 76,2 53,0 SPT13 Comments Highway Weather s / 4. COMMETAR OF THE With the completion of noise measurements the data base of the existing acoustic background is created for the critical points of the project, during the phase before the beginning of construction period. Those data of the measurements of the acoustic environment before the implementation of the highway form the zero level for the monitoring of the area during the construction phase of the project and until the completion. APPEDIX: oise record forms Ε1, Ε2, Ε3, Ε4, Ε5, Ε6 8

9 OISE REGISTRATIO FORM E1 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 13/02/ minutes REGISTRATIO UMBER: 01 Page 1 of 3 MEASUREMET LOCATIO: Demir Kapija Canyon DISTACE OF THE MICROPHOE FROM THE MOTORWA: ot applicable ISTRUMET: Castle Pro-DX MICROPHOE'S LOCATIO: on inhabited area - ext to an unpaved road DATE OF ISTRUMET'S LAST CALIBRATIO: 13/03/2013 Leq(5m)= 66,0 db(a) Lmax(5m)= 86,0 db(a) Lmin(5m)= 42,9 db(a) 1. Strong wind 2. Two trucks passed from the unpaved road 3. Participants: Coltellacci Al., Siouta., AndrisP. MEASUREMET RESPOSIBLE PERSO: MICHALIS KARASOULAS SIGATURE: Michalis Karasoulas

10 OISE REGISTRATIO FORM E1 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 13/02/ minutes REGISTRATIO UMBER: 04 Page 2 of 3 MEASUREMET LOCATIO: Demir Kapija Canyon DISTACE OF THE MICROPHOE FROM THE MOTORWA: ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 13/03/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to an unpaved road Leq(5m)= 46,3 db(a) Lmax(5m)= 60,5 db(a) Lmin(5m)= 39,1 db(a) 1. o trucks passed 2. Participants: Coltellacci Al., Siouta., AndrisP. MEASUREMET RESPOSIBLE PERSO: MICHALIS KARASOULAS SIGATURE: Michalis Karasoulas

11 OISE REGISTRATIO FORM E1 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 01/03/ minutes REGISTRATIO UMBER: 18 Page 3 of 3 MEASUREMET LOCATIO: Demir Kapija Canyon DISTACE OF THE MICROPHOE FROM THE MOTORWA: ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to an unpaved road Leq(5m)= 56,9 db(a) Lmax(5m)= 82,7 db(a) Lmin(5m)= 40,0 db(a) 1. weather MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

12 OISE REGISTRATIO FORM E2 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 13/02/ minutes REGISTRATIO UMBER: 02 Page 1 of 3 MEASUREMET LOCATIO: Demir Kapija Gorge DISTACE OF THE MICROPHOE FROM THE MOTORWA:2m ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 13/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to the existing highway, between two tunnels Leq(5m)= 82,2 db(a) Lmax(5m)= 98,1 db(a) Lmin(5m)= 68,4 db(a) 1. highway inside gorge 2. traffic 3. Participants: Coltellacci Al., Siouta., AndrisP. MEASUREMET RESPOSIBLE PERSO: MICHALIS KARASOULAS SIGATURE: Michalis Karasoulas

13 OISE REGISTRATIO FORM E2 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 13/02/ minutes REGISTRATIO UMBER: 03 Page 2 of 3 MEASUREMET LOCATIO: Demir Kapija Gorge DISTACE OF THE MICROPHOE FROM THE MOTORWA:2m ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 13/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to the existing highway, between two tunnels Leq(5m)= 74,0 db(a) Lmax(5m)= 90,1 db(a) Lmin(5m)= 61,4 db(a) 1. highway inside gorge 2. traffic 3. Participants: Coltellacci Al., Siouta., AndrisP. MEASUREMET RESPOSIBLE PERSO: MICHALIS KARASOULAS SIGATURE: Michalis Karasoulas

14 OISE REGISTRATIO FORM E2 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 1/03/ minutes REGISTRATIO UMBER: 17 Page 3 of 3 MEASUREMET LOCATIO: Demir Kapija Gorge DISTACE OF THE MICROPHOE FROM THE MOTORWA:2m ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to the existing highway, between two tunnels Leq(5m)= 79,8 db(a) Lmax(5m)= 85,5 db(a) Lmin(5m)= 72,5 db(a) 1. highway inside gorge 2. traffic MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

15 OISE REGISTRATIO FORM E3 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 05 Page 1 of 3 MEASUREMET LOCATIO: Miravci DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX MICROPHOE'S LOCATIO: City centre - Road next to central plaza DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 Leq(5m)= 55,7 db(a) Lmax(5m)= 76,1 db(a) Lmin(5m)= 38,3 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

16 OISE REGISTRATIO FORM E3 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 10 Page 2 of 3 MEASUREMET LOCATIO: Miravci DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: City centre - Road next to central plaza Leq(5m)= 58,3 db(a) Lmax(5m)= 84,0 db(a) Lmin(5m)= 39,9 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

17 OISE REGISTRATIO FORM E3 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 1/03/ minutes REGISTRATIO UMBER: 15 Page 3 of 3 MEASUREMET LOCATIO: Miravci DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: City centre - Road next to central plaza Leq(5m)= 60,7 db(a) Lmax(5m)= 80,2 db(a) Lmin(5m)= 44,2 db(a) 1. Local traffic MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

18 OISE REGISTRATIO FORM E4 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 05 Page 1 of 3 MEASUREMET LOCATIO: Smokvica DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX MICROPHOE'S LOCATIO: City centre - Road next to central plaza DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 Leq(5m)= 48,0 db(a) Lmax(5m)= 79,3 db(a) Lmin(5m)= 34,9 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

19 OISE REGISTRATIO FORM E4 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 08 Page 2 of 3 MEASUREMET LOCATIO: Smokvica DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: City centre - Road next to central plaza Leq(5m)= 50,4 db(a) Lmax(5m)= 75,6 db(a) Lmin(5m)= 37,0 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

20 OISE REGISTRATIO FORM E4 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 01/03/ minutes REGISTRATIO UMBER: 13 Page 3 of 3 MEASUREMET LOCATIO: Smokvica DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: City centre - Road next to central plaza Leq(5m)= 48,4 db(a) Lmax(5m)= 64,1 db(a) Lmin(5m)= 36,9 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

21 OISE REGISTRATIO FORM E5 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 07 Page 1 of 3 MEASUREMET LOCATIO: Miletkovo DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX MICROPHOE'S LOCATIO:City centre - Road next to Church DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 Leq(5m)= 46,2 db(a) Lmax(5m)= 75,0 db(a) Lmin(5m)= 37,5 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

22 OISE REGISTRATIO FORM E5 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 09 Page 2 of 3 MEASUREMET LOCATIO: Miletkovo DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO:City centre - Road next to Church Leq(5m)= 42,9 db(a) Lmax(5m)= 64,3 db(a) Lmin(5m)= 37,6 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

23 OISE REGISTRATIO FORM E5 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 01/03/ minutes REGISTRATIO UMBER: 14 Page 3 of 3 MEASUREMET LOCATIO: Miletkovo DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO:City centre - Road next to Church Leq(5m)= 51,7 db(a) Lmax(5m)= 66,6 db(a) Lmin(5m)= 38,3 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

24 OISE REGISTRATIO FORM E6 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 22/02/ minutes REGISTRATIO UMBER: 11 Page 1 of 3 MEASUREMET LOCATIO: South Portal Tunnel 1 DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX MICROPHOE'S LOCATIO: on inhabited area - ext to the portal of the tunnel DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 Leq(5m)= 71,7 db(a) Lmax(5m)= 90,1 db(a) Lmin(5m)= 49,3 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

25 OISE REGISTRATIO FORM E6 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 23/02/ minutes REGISTRATIO UMBER: 12 Page 2 of 3 MEASUREMET LOCATIO: South Portal Tunnel 1 DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to the portal of the tunnel Leq(5m)= 58,0 db(a) Lmax(5m)= 69,3 db(a) Lmin(5m)= 44,9 db(a) 1. MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

26 OISE REGISTRATIO FORM E6 - HIGHWA E-75 / SECTIO DEMIR KAPIJA - SMOKVICA DATE - MEASUREMET TIME: 01/03/ minutes REGISTRATIO UMBER: 16 Page 3 of 3 MEASUREMET LOCATIO: South Portal Tunnel 1 DISTACE OF THE MICROPHOE FROM THE MOTORWA:ot applicable ISTRUMET: Castle Pro-DX DATE OF ISTRUMET'S LAST CALIBRATIO: 22/02/2013 MICROPHOE'S LOCATIO: on inhabited area - ext to the portal of the tunnel Leq(5m)= 63,2 db(a) Lmax(5m)= 76,2 db(a) Lmin(5m)= 53,0 db(a) 1. Traffic noise MEASUREMET RESPOSIBLE PERSO: PERIKLIS ADRIS SIGATURE: Periklis Andris

Protocol for Ambient Level Noise Monitoring

Protocol for Ambient Level Noise Monitoring July 2015 Protocol for Ambient Level Noise Monitoring L pressure =10.log [10 (Lp/10) - 10 (LpBackground/10) ] L pressure = 10.log [10 (Lp/10) - 10 (LpBackground/10) ] CENTRAL POLLUTION CONTROL BOARD P

More information

Fundamentals of Environmental Noise Monitoring CENAC

Fundamentals of Environmental Noise Monitoring CENAC Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative

More information

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01 Heslington East Campus Details of Noise Modelling and Noise Survey Report ref Heslington East Campus Details of Noise Modelling and Noise Survey January 2008 Arup Acoustics Admiral House, Rose Wharf, 78

More information

Pfizer Ireland Pharmaceuticals

Pfizer Ireland Pharmaceuticals Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,

More information

Week 1. Signals & Systems for Speech & Hearing. Sound is a SIGNAL 3. You may find this course demanding! How to get through it:

Week 1. Signals & Systems for Speech & Hearing. Sound is a SIGNAL 3. You may find this course demanding! How to get through it: Signals & Systems for Speech & Hearing Week You may find this course demanding! How to get through it: Consult the Web site: www.phon.ucl.ac.uk/courses/spsci/sigsys (also accessible through Moodle) Essential

More information

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare Environmental

More information

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA

More information

REPORT PERIOD: JANUARY 01 MARCH

REPORT PERIOD: JANUARY 01 MARCH QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT PERIOD: JANUARY 01 MARCH 31 2018 IE LICENCE REF. NO. W0178-02 APRIL 2018 QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT

More information

Offaly County Council

Offaly County Council Derryclure Landfill Facility, Derryclure, Co. Offaly Annual Monitoring Report Waste Licence Reg. No. W0029-04 Report Date: th October 15 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth

More information

Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver. Vancouver Airport Authority

Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver. Vancouver Airport Authority Portable Noise Monitoring Report March 5 - April 24, 2016 The Museum of Vancouver Vancouver Airport Authority September 27, 2016 Table of Contents INTRODUCTION... 2 OBJECTIVES... 2 VANCOUVER: AIRCRAFT

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 20 June 2017 Doc no. 102-QM-RP-4-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown

More information

BASELINE NOISE MONITORING SURVEY

BASELINE NOISE MONITORING SURVEY t m s environment ltd TMS Environment Ltd 53 Broomhill Drive Tallaght Dublin 24 Phone: +353-1-4626710 Fax: +353-1-4626714 Web: www.tmsenv.ie BASELINE NOISE MONITORING SURVEY UNIVERSITY COLLEGE DUBLIN Report

More information

NOISE IMPACT ASSESSMENT 2016

NOISE IMPACT ASSESSMENT 2016 Panther Environmental Solutions Ltd, Unit 4, Innovation Centre, Institute of Technology, Green Road, Carlow, Ireland. Mobile: 087-8519284 Telephone /Fax: 059-9134222 Email: info@pantherwms.com Website:

More information

A Guide to Environmental Noise Measurement Terminology

A Guide to Environmental Noise Measurement Terminology A Guide to Environmental Noise Measurement inology A summary of parameters and functions shown by the Optimus Sound Level Meters and Trojan Noise Nuisance Recorder A FREE ebook from The Noise Experts Environmental

More information

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE On behalf of: ITV plc Report No. 22396.01v1 October 2014 ITV CORONATION

More information

Xtratherm Limited Kells Road, Navan, Co Meath

Xtratherm Limited Kells Road, Navan, Co Meath Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre Ennis Road Limerick Kells Road, Navan, Co Meath Annual Environmental Noise Survey 2017 IPPC Licence

More information

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Date: 09 March 2016 REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Client: Edinburgh Limited Report Author:... Dr R. Peters Principal Consultant

More information

Appendix D: Preliminary Noise Evaluation

Appendix D: Preliminary Noise Evaluation Appendix D: Preliminary Noise Evaluation Acoustics The study of sound and its properties is known as acoustics. By considering basic physical properties of sound and the acoustic environment, the potential

More information

Noise Study for Proposed Mavis Tire

Noise Study for Proposed Mavis Tire Noise Study for Proposed Mavis Tire Hyde Park, New York April 4, 2017 Prepared For: Town of Hyde Park Planning Board 4383 Albany Post Road Hyde Park, NY 12538 Prepared By: Novus Engineering, P.C. 25 Delaware

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:

More information

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Appendix G Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Environmental Management Plan G May 2014 Colton Coal Mine Aldershot, Queensland Review of Baseline Noise Monitoring

More information

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times 765 kv Substation Acoustic Noise Impact Study by Predictive Software and

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 10 October 2017 Suite 6, Level 1,, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Roche Ireland Limited

Roche Ireland Limited Limited Clarecastle, Co. Clare Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 1 st February 17 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth Report No.

More information

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary Sheringham Shoal Cawston, Norfolk Substation Noise Assessment Summary Document title: Substation Noise Assessment Summary Status: Final Date: 13 March 2015 Project name: Sheringham Shoal, Cawston, Norfolk

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 15 December 2017 Suite 6, Level 1, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1 Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC Final Report Rev 1 Noise Impact Assessment RWDI # 1502274 SUBMITTED TO Paul Dufault Project Manager Metro Vancouver 4330

More information

DOWNWIND LEG NOISE MONITORING SUMMARY REPORT

DOWNWIND LEG NOISE MONITORING SUMMARY REPORT Tel: 43-232-6771 Fax: 43-232-6762 RWDI AIR Inc. #1, 736-8 th Avenue S.W. Calgary, Alberta, Canada T2P 1H4 Email: solutions@rwdi.com DOWNWIND LEG NOISE MONITORING SUMMARY REPORT Introduction This report

More information

Thank you for purchasing the Boogie sound level meter from SINUS Messtechnik GmbH.

Thank you for purchasing the Boogie sound level meter from SINUS Messtechnik GmbH. à ƒ ƒ ƒ 0DQXDO 0LQL6FKDOOSHJHOPHVVHU%RRJLH Œ Thank you for purchasing the Boogie sound level meter from SINUS Messtechnik GmbH. Please read this manual carefully before using the sound level meter. We

More information

Technical Report Noise and Vibration

Technical Report Noise and Vibration Technical Report Noise and Vibration Eagle Mine and Humboldt Mill Prepared for: Eagle Mine, LLC 4547 County Road 601 Champion, MI 49814 Date: August 8, 2014 TriMedia Project Number: 2014-083 Table of Contents

More information

Southwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB

Southwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Study For Southwest Anthony Henday Drive At Wedgewood Heights

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015

More information

Environmental Noise Assessment Cambourne to Cambridge options

Environmental Noise Assessment Cambourne to Cambridge options Environmental Noise Assessment Cambourne to Cambridge options CLIENT: Cambridgeshire County Council Major Infrastructure Delivery Box No SH1311 Shire Hall Cambridge CB3 0AP CONTACT: Tim Watkins REPORTED

More information

TERRESTRIAL S Noise Barriers

TERRESTRIAL S Noise Barriers TERRESTRIAL S Noise Barriers INTRODUCTION Materials have different rates of absorbing or reflecting sound. Typically flat, hard, or high density surfaces reflect sound where soft, fluffy, and low density

More information

Appendix L Noise Technical Report. Rehabilitation and Restoration of the Longfellow Bridge

Appendix L Noise Technical Report. Rehabilitation and Restoration of the Longfellow Bridge Appendix L Noise Technical Report Rehabilitation and Restoration of the Longfellow Bridge Noise Technical Report Rehabilitation and Restoration of the Longfellow Bridge Boston, MA May, 2011* Prepared by

More information

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE Head Office Postal Address T 02 9908 1270 Suite 9 PO Box 270 F 02 9908 1271 38-46 Albany St Neutral Bay 2089 E info@acousticdynamics.com.au St Leonards 2065 ABN: 36 105 797 715 W www.acousticdynamics.com.au

More information

Lesson 3 Measurement of sound

Lesson 3 Measurement of sound Lesson 3 Measurement of sound 1.1 CONTENTS 1.1 Contents 1 1.2 Measuring noise 1 1.3 The sound level scale 2 1.4 Instruments used to measure sound 6 1.5 Recording sound data 14 1.6 The sound chamber 15

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date November 2014 Issue No 1 TABLE OF CONTENTS 1. Introduction/Purpose 2. Responsibility and Authority 3. Noise Monitoring 4.

More information

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S Pre-Construction Sound Study Substation DRAFT January 2011 D A T A AN AL Y S IS S OL U T I ON S TABLE OF CONTENTS 1.0 INTRODUCTION...1 2.0 SOUND LEVEL MONITORING...1 3.0 SOUND MODELING...4 3.1 Modeling

More information

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick. info@axisenv.ie 00353 61 324587 Unit 4, Osberstown Industrial Park, Caragh

More information

Measuring procedures for the environmental parameters: Acoustic comfort

Measuring procedures for the environmental parameters: Acoustic comfort Measuring procedures for the environmental parameters: Acoustic comfort Abstract Measuring procedures for selected environmental parameters related to acoustic comfort are shown here. All protocols are

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 11 August 16 Doc no. 102-QM-RP-1-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Assessment of rail noise based on generic shape of the pass-by time history

Assessment of rail noise based on generic shape of the pass-by time history Proceedings of Acoustics 23 Victor Harbor 7-2 November 23, Victor Harbor, Australia Assessment of rail noise based on generic shape of the pass-by time history Valeri V. enchine, Jonathan Song Science

More information

Pipeline Blowdown Noise Levels

Pipeline Blowdown Noise Levels Pipeline Blowdown Noise Levels James Boland 1, Henrik Malker 2, Benjamin Hinze 3 1 SLR Consulting, Acoustics and Vibration, Brisbane, Australia 2 Atkins Global, Acoustics, London, United Kingdom 3 SLR

More information

Noise Assessment for Planning Purposes - as per TAN11

Noise Assessment for Planning Purposes - as per TAN11 Noise Assessment for Planning Purposes - as per TAN11 Report No: 1703035R01A Report Status: Final Report (Amended) Dated: 23 October 2017 Purchase order No: n/a Prepared for: Garep Demirci 73 Spencer David

More information

Bickerdike Allen Partners

Bickerdike Allen Partners 25 CHURCH ROAD, SE19 ENTERTAINMENT NOISE ASSESSMENT Report to Kayode Falebita Kingsway International Christian Centre 3 Hancock Road Bromley-By-Bow London E3 3DA A9540/R01-A-HT 26/07/2012 CONTENTS Page

More information

A Guide to Noise Measurement Terminology

A Guide to Noise Measurement Terminology A Guide to Noise Measurement inology A summary of parameters and functions shown by the Optimus Sound Level Meters, Trojan Noise Nuisance Recorder and dosebadge Noise Dosimeter A FREE ebook from The Noise

More information

WITHIN GENERATOR APPLICATIONS

WITHIN GENERATOR APPLICATIONS POWER SYSTEMS TOPICS 9 Measuring and Understanding Sound WITHIN GENERATOR APPLICATIONS INTRODUCTION When selecting a generator, there are many factors to consider so as not to negatively impact the existing

More information

ABSTRACT. Noise Monitoring Results. from. The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC)

ABSTRACT. Noise Monitoring Results. from. The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC) ABSTRACT Noise Monitoring Results from The USAF atmospheric interceptor technology (ait) launch From the Kodiak Launch Complex (KLC) As part of the monitoring and mitigation obligation of the United States

More information

Annual Noise Monitoring Report

Annual Noise Monitoring Report Noise monitoring program Annual report sum mary 2 0 1 7 Annual Noise Monitoring Report The Vancouver Fraser Port Authority has a noise m onitoring program in place to better understand the source and intensity

More information

Week I AUDL Signals & Systems for Speech & Hearing. Sound is a SIGNAL. You may find this course demanding! How to get through it: What is sound?

Week I AUDL Signals & Systems for Speech & Hearing. Sound is a SIGNAL. You may find this course demanding! How to get through it: What is sound? AUDL Signals & Systems for Speech & Hearing Week I You may find this course demanding! How to get through it: Consult the Web site: www.phon.ucl.ac.uk/courses/spsci/sigsys Essential to do the reading and

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:

More information

Memorandum 1.0 Highway Traffic Noise

Memorandum 1.0 Highway Traffic Noise Memorandum Date: September 18, 2009 To: Chris Hiniker, SEH From: Stephen B. Platisha, P.E. Re: Updated CSAH 14 Noise Analysis The purpose of this memorandum is to provide the results of the revised traffic

More information

Railway transport sound measurement

Railway transport sound measurement Railway transport sound measurement Žilina 2010 Tomáš Závodský Contents 1. sound basic information 2. sound measurement 3. sound level meter 4. train sound 5. sound protection Recorded sound of the passing

More information

SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011

SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011 Date: 9 June 2012 Ref: SUMMARY REPORT OF NOISE MONITORING AT MEATH GREEN OCTOBER 2010 TO SEPTEMBER 2011 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by

More information

SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011

SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011 Date: 24 June 2012 Ref: 00148/Felbridge/002/rp SUMMARY REPORT OF NOISE MONITORING AT FELBRIDGE NOVEMBER 2010 TO OCTOBER 2011 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant

More information

Proposed Hydropower Archimedean Screw Osney Lock and Weir, Oxford. Noise Impact Assessment TECHNICAL REPORT

Proposed Hydropower Archimedean Screw Osney Lock and Weir, Oxford. Noise Impact Assessment TECHNICAL REPORT Proposed Hydropower Archimedean Screw Osney Lock and Weir, Oxford Noise Impact Assessment TECHNICAL REPORT Hydropower Archimedean Screw Noise Impact Assessment Prepared for: The Low Carbon Hub, 23 Park

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date 31/7/15 Issue No 2e DRAFT TABLE OF CONTENTS 1. Policy Statement 2. Introduction/Purpose 3. Responsibility and Authority

More information

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W0115-01 Report Date: 09 th July 2013 Report Number: 3220-13-03 Version 0 AXIS environmental services 40 Coolraine

More information

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO. 01127-E VERSION A APRIL 2017 PREPARED FOR HANSON CONSTRUCTION MATERIALS PTY LTD LOT 151 PEATS RIDGE ROAD CALGA NSW 2250 DOCUMENT CONTROL Version

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 1996-2 Second edition 2007-03-15 Acoustics Description, measurement and assessment of environmental noise Part 2: Determination of environmental noise levels Acoustique Description,

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:

More information

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS HASTINGS HOUSE, AUCKLAND PARK, MILTON KEYNES, MK1 1BU 01908 642846 01908 642814

More information

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA

More information

Appendix F Noise and Vibration

Appendix F Noise and Vibration 1.1 Wayside Noise Model Methods Wayside noise collectively refers to noise generated by railcars and locomotives (i.e., without including horn noise). The joint lead agencies used noise measurements from

More information

Roche Ireland Limited

Roche Ireland Limited Roche Ireland Limited Clarecastle, Co. Clare Environmental Noise Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 6 th October 17 Fitz Scientific Unit 35A, Boyne Business Park,

More information

Standard Octaves and Sound Pressure. The superposition of several independent sound sources produces multifrequency noise: i=1

Standard Octaves and Sound Pressure. The superposition of several independent sound sources produces multifrequency noise: i=1 Appendix C Standard Octaves and Sound Pressure C.1 Time History and Overall Sound Pressure The superposition of several independent sound sources produces multifrequency noise: p(t) = N N p i (t) = P i

More information

Noise Mitigation Study Pilot Program Summary Report Contract No

Noise Mitigation Study Pilot Program Summary Report Contract No Ohio Turnpike Commission Noise Mitigation Study Pilot Program Summary Report Contract No. 71-08-02 Prepared For: Ohio Turnpike Commission 682 Prospect Street Berea, Ohio 44017 Prepared By: November 2009

More information

Assured Monitoring Group

Assured Monitoring Group Assured Monitoring Group YARRANLEA SOLAR FARM NOISE & VIBRATION IMPACT ASSESSMENT JANUARY 2017 I3 CONSULTING PTY LTD Project ID. 10734 R_1 DATE OF RELEASE: 15/02/2017 Table 1: Document approval Name Position

More information

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2 www.semargroup.org, www.ijsetr.com ISSN 2319-8885 Vol.03,Issue.24 September-2014, Pages:4885-4889 Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2 1 Dept of Mechanical

More information

PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS

PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS PRACTICAL METHODOLOGY FOR FAST ENVIRONMENTAL FIELD MEASUREMENTS PACS REFERENCE: 43.50.Sr Rodrigues, Rui M. G. C.; Carvalho, António P. O. University of Porto, Faculty of Engineering, Laboratory of Acoustics,

More information

Airborne Sound Insulation

Airborne Sound Insulation Airborne Sound Insulation with XL2-TA Sound Level Meter This application note describes the verification of the airborne sound insulation in buildings with the XL2-TA Sound Level Meter. All measurements

More information

APPENDIX F BASELINE NOISE REPORT

APPENDIX F BASELINE NOISE REPORT APPENDIX F BASELINE NOISE REPORT APPENDIX F BASELINE NOISE REPORT F BASELINE NOISE REPORT Contents Summary A Baseline Noise Report was prepared for Damhead Creek 2. This is presented in this Appendix

More information

R e p o r t th A u g u s t

R e p o r t th A u g u s t N o ise Mon it o r ing R e p o r t L e g a c y W a y T u n n e l M o n i t o r i n g P o s t C o m m is s i o n ing T es ts V e n ti la t ion S t a c ks Jun e 20 1 6 R e p o r t 3557 4 th A u g u s t 2

More information

Digital Signal Processing Audio Measurements Custom Designed Tools. Loudness measurement in sone (DIN ISO 532B)

Digital Signal Processing Audio Measurements Custom Designed Tools. Loudness measurement in sone (DIN ISO 532B) Loudness measurement in sone (DIN 45631 ISO 532B) Sound can be described with various physical parameters e.g. intensity, pressure or energy. These parameters are very limited to describe the perception

More information

Bloomfield Colliery. Quarterly Noise Monitoring. and Compliance Assessment September Report Number Q R2.

Bloomfield Colliery. Quarterly Noise Monitoring. and Compliance Assessment September Report Number Q R2. Bloomfield Colliery Quarterly Noise Monitoring and Compliance Assessment September 2015 Report Number Q59 630.01053-R2 15 October 2015 Bloomfield Collieries Four Mile Creek Road Ashtonfield NSW 2323 Version:

More information

Appendix G Noise and Vibration Assessment

Appendix G Noise and Vibration Assessment Appendix G Noise and Vibration Assessment Annex G1: Noise Perception and Terminology Annex G2: Baseline Noise Monitoring Annex G3: Construction Information Annex G4: Operational Information Annex G1: Noise

More information

Environmental Noise Survey For. Vista Coal Project. Prepared for: Coalspur Mines Ltd. Prepared by: S. Bilawchuk, M.Sc., P.Eng.

Environmental Noise Survey For. Vista Coal Project. Prepared for: Coalspur Mines Ltd. Prepared by: S. Bilawchuk, M.Sc., P.Eng. aci Acoustical Consultants Inc. 5031 210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373, Fax: (780) 414-6376 www.aciacoustical.com Environmental Noise Survey For Vista Coal Project Prepared

More information

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE Cedric Roberts Environmental Operations, Integrated Assessment, Queensland Environmental Protection Agency, 160 Ann Street, Brisbane, Queensland,

More information

PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT RODEO STATION

PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT RODEO STATION PURPLE LINE EXTENSION SECTION 2 AMBIENT NOISE LEVEL REPORT METRO PROJECT 865522 RODEO STATION Kleinfelder Section Table of Contents 1.0 Introduction... 4 2.0 Noise Measurement Procedure... 4 3.0 Noise

More information

DiGi++ Noise Meter. Main functions

DiGi++ Noise Meter. Main functions Main functions DiGi++ Noise Meter This application brings the functionalities of a Sound Level Meter (SLM) and of a Spectrum Analizer (RTA) to your phone: mobile hardware introduce some limitations (lower

More information

Terms of Reference of Aircraft Noise at IGI Airport, New Delhi

Terms of Reference of Aircraft Noise at IGI Airport, New Delhi Terms of Reference of Aircraft Noise at IGI Airport, New Delhi In order to determine the noise impact from aircraft flights and identify potential measures to reduce the noise impact, an Aircraft Noise

More information

Chapter 12. Preview. Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect. Section 1 Sound Waves

Chapter 12. Preview. Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect. Section 1 Sound Waves Section 1 Sound Waves Preview Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect Section 1 Sound Waves Objectives Explain how sound waves are produced. Relate frequency

More information

REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012

REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012 Date: 25 July 2013 Ref: REPORT OF NOISE MONITORING AT HAYWARDS HEATH OCTOBER 2011 TO NOVEMBER 2012 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H.

More information

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording Environmental Noise Boundary noise assessments Noise nuisance complaints Measurements

More information

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Prepared by Umwelt (Australia) Pty Limited on behalf of Mackas Sand Pty Ltd

More information

91 Street Earth Berm Removal in Edmonton, Alberta

91 Street Earth Berm Removal in Edmonton, Alberta aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Monitoring For The 91 Street Earth Berm Removal in Edmonton,

More information

McGill Environmental Ltd.

McGill Environmental Ltd. McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan

More information

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July

More information

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for

More information

Engineering a Sustainable Future for Our Environment

Engineering a Sustainable Future for Our Environment NOISE COMPLIANCE REPORT FOR MULTIQUIP AGGREGATES 5152 OALLEN FORD ROAD, BUNGONIA Prepared for: Alexander Cox, Environmental Officer Multiquip Aggregates Prepared by: Peter Gangemi, Acoustic Engineer R

More information

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA W Les Huson 1 1 L Huson & Associates Pty Ltd les@lhuson.com ABSTRACT Results of two channel simultaneous audio recordings

More information

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 OneSteel Recycling Pty Ltd 14-Jul-2017 60493017 OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 Testing

More information

AN547 - Why you need high performance, ultra-high SNR MEMS microphones

AN547 - Why you need high performance, ultra-high SNR MEMS microphones AN547 AN547 - Why you need high performance, ultra-high SNR MEMS Table of contents 1 Abstract................................................................................1 2 Signal to Noise Ratio (SNR)..............................................................2

More information

REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012

REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012 Date: 25 July 2013 Ref: REPORT OF NOISE MONITORING AT LEIGH SEPTEMBER 2011 TO NOVEMBER 2012 Client: Gatwick Airport Limited Report Author :... Dr R. Peters Principal Consultant Approved by :. A.V.H. Holdich

More information

Attended Noise Monitoring - Quarter Ending September 2013

Attended Noise Monitoring - Quarter Ending September 2013 Unity Mining Level 10, 350 Collins St Melbourne VIC 3000 Version: Page 2 PREPARED BY: ABN 29 001 584 612 Units 7-8, 26-28 Napier Close Deakin ACT 2600 Australia (PO Box 9344 Deakin ACT 2600 Australia)

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report

More information

Data Sheet. Description The 6918 is a unit consisting of a directional and an omni-directional microphone for hearing instruments.

Data Sheet. Description The 6918 is a unit consisting of a directional and an omni-directional microphone for hearing instruments. Description The 6918 is a unit consisting of a directional and an omni-directional microphone for hearing instruments. Features - Low noise CMOS amplifier with improved power supply feedtrough attenuation

More information

The db Concept. Chapter six

The db Concept. Chapter six Chapter six The db Concept CHAPTER OUTLINE dbdpower Ratio... 40 dbdamplitude Ratio... 40 From db to Power or Amplitude Ratio... 41 Conversion Table... 41 Reference Values... 41 Other Relative Units...43

More information