Vorderer Weinberg 26 D Backnang Tel.:+49 (0) (Fax.:-19) K Series PWM Sine Wave Inverters with Toroidal Transformers

Size: px
Start display at page:

Download "Vorderer Weinberg 26 D Backnang Tel.:+49 (0) (Fax.:-19) K Series PWM Sine Wave Inverters with Toroidal Transformers"

Transcription

1 with Toroidal Transformers

2 Important Safety Information Installation and maintenance of these inverters must be performed by skilled personnel only. Lethal voltages are present inside the device therefore, the device must be opened by qualified and skilled electricians only. Hazardous live voltages may be present even if the inverter has been disconnected. This manual describes how to operate and handle the device properly. Therefore, please read this manual carefully before putting it into operation. Symbols used in this manual To ensure optimal usage of your inverter please note the following explanations of the symbols used in this manual. This symbol indicates a feature or circumstance that is important for optimal and convenient use of the inverter. Non-observance of the associated instructions may adversely affect the proper functioning of the device. This symbol indicates circumstances that are very important for the safety of the user and nonobservance of which may lead to damage of components or malfunctions or the risk of injuries. Example: Disconnect from mains before opening the device. This symbol indicates additional information Subject to change without notice Status: July 2007 KACO NEW ENERGY GMBH K SERIES MANUAL

3 Table of Contents: 1 Introducing KACO NEW ENERGY GmbH 4 2 a brief Description 5 3 Notes on Inverter Operation 5 4 Functional Principle of Inverters Description of Components Protective Functions 7 5 Installation of the Inverter General Information about the Place of Installation Mechanical Dimensions 9 6 Electrical Connections General Information AC Connection DC Connection Connecting the Remote Control Switch 15 7 Inverter Operation Operation of K 150 and K 200 Inverters Operation of K 300 to K 3000 Inverters 16 8 Technical Data Type Plate Description of Optional Features Data Sheet 19 9 EU Declaration of Conformity Warranty and Service Troubleshooting and Fault Diagnostics Troubleshooting Transport Damages 22 KACO NEW ENERGY GMBH K SERIES MANUAL

4 1 Introducing KACO NEW ENERGY GmbH KACO NEW ENERGY is your powerful partner for system solutions in the field of power converters and power electronics which are used in industrial and railway applications. Our company has been developing, designing and manufacturing power converters and electronics for more than 60 years. Our capable and efficient development and projecting team will meet all your specific demands and ensure fast response to your queries. History: Founded in 1914 under the name of "Kupfer-Asbest-Company Gustav Bach" (KACO), our company was Germany s first special factory to produce ring gaskets used in the automotive industry. In 1927, the product range was extended by electrotechnical products and it has permanently been enhanced and expanded since that date. By 1970 the electrotechnical division had grown significantly and was transferred to a separate company Bach & Co. KACO Elektrowerk. In 1991, the company name was changed to KACO ELEKTROTECHNIK Bach GmbH + Co. In 1996, the company, whose name meanwhile had been changed to KACO ELEKTROTECHNIK GmbH, joined the American Danaher Corporation of Washington, DC. On 1 January 1999 the strongly expanding Geraetetechnik Profit Center focused on power converter technology and power electronics was re-established as an independent company under the name of KACO GERÄTETECHNIK GmbH. Our name obliges. For more than 60 years, KACO GERÄTETECHNIK has been developing and manufacturing power converters at its location in Germany. High product quality and long life cycles are our hallmarks. KACO NEW ENERGY GMBH K SERIES MANUAL

5 2 a brief Description inverters convert DC voltage into sine-wave AC voltage. This inverter type has power stage pulsewidth modulation, a technique that ensures simple and cost-efficient inverter design and low space requirements at the same time. As the device is fully microprocessor-controlled, further options (upgrades, extensions, special functions) can be implemented. The inverter disconnects in the event of an overload condition and automatically starts up again after 10 seconds. After having disconnected in the event of excess temperature it automatically starts again when the power stage has cooled down by approx. 10 C. Low/high voltage cut-off protects the DC voltage source (storage batteries, battery) and the inverter against non-permissible operating conditions. All operating conditions are signaled by three LEDs located next to the push-button switch. Special devices, which are particularly resistant to mechanical vibrations, can be manufactured on request - these devices are typically used for railway and emergency vehicles. In consequence of the many optional features which are available for these inverters (see Chapter 8.2) there may be deviations between this manual and your inverter as, for example, a different housing (Option Q). Please note the additional documentation in the clear plastic folder inside the back cover of this manual. All electronic, electromechanical and mechanical components are suitable for operating temperatures between 0 C and 40 C. Devices with options D and E are built for an extended temperature range from -25 C to +70 C. The complete unit is approved for a storage temperature between -25 C and C, and fully compliant with the RFI suppression classification according to EN B (pursuant to VDE 0871). 3 Notes on Inverter Operation The inverter has been manufactured in accordance with the following specifications: VDE 0558 Part 8 + Part 11 EN Part Part 1-3 VDE 0100 Part 410 Since the device is a potential-free power supply, the protective earth contact of the outlet is not connected to the housing of devices with optional feature S (see VDE 0100 Part 410 chapters and ). If multiple loads are connected to the outlet of the inverter, their housings must be interconnected by ungrounded, isolated potential equalization leads. This is achieved, for example, by connecting all loads to a multiple socket-outlet with protective earth contacts. In this way, potential equalization is effected automatically. If your device features an internal mains/inverter change over unit which requires a connection to the mains, the protective earth contact of the outlet will be connected. In contrast to the section above, the protective earth leads of the loads must be connected to the protective earth terminal of the inverter in this case. Please observe all relevant VDE regulations for connecting the devices to the mains. KACO NEW ENERGY GMBH K SERIES MANUAL

6 4 Functional Principle of Inverters Figure 1 Figure 2 DC Input + SUBJECT TO CHANGE WITHOUT NOTICE DC Input - EMC Filter Input Capacity Shunt MOSFET Drivers Filter Coil Microprocessor KACO-GERÄTETECHNIK GmbH Neckarsulm BENENNUNG Functional Principle of Functional principle of K 150, K 200, K500 and K1000 devices + SUBJECT TO CHANGE WITHOUT NOTICE - EMC Filter Input Capacity MOSFET Drivers Filter Coil Microprocessor BENENNUNG KACO-Gerätetechnik GmbH Neckarsulm Functional Principle of Functional principle of K 300, K 500N and K 3000 devices U EMC-Filter V PE DATUM NAME GEZ GEPR. VERSIONS-NR. V ZEICHNUNGS-NR. Vo\H\K-Serie\Funktionsprinzip U EMC Filter V PE DATUM NAME GEZ GEPR. VERSIONS-NR. V ZEICHNUNGS-NR. Vo-Pr/Hand/K-Serie KACO NEW ENERGY GMBH K SERIES MANUAL

7 4.1 Description of Components EMC Filter Specially adapted discrete EMC filters are integrated on the board (DC and AC side). These filters ensure compliance with EMC standard threshold values. Due to their high performance there is no need to use ready-made standard line filters Input Capacity inverters have a high input capacity to ensure proper operation of the device even if long DC leads are used, and to reduce adverse effects on the batteries. Filter Coil The filter coil ensures that the output current is sinusoidal. It is manufactured in a special process, and its design guarantees the high efficiency of our inverters. DC Voltage and Current Monitoring The input current (respectively the output current on K300, K500N and K3000 devices) and the input voltage are monitored by a precise measurement circuit which ensures that the inverter is only operated within its specifications. Microprocessor The output voltage and operating modes of the device are controlled by a powerful single chip microcontroller. 4.2 Protective Functions The following monitoring and protective functions are integrated in the inverter: Overvoltage suppressors/vdrs on the DC side for protection in case of lightning strokes VDRs to protective earth for protection of the inverter against burst and surge pulses Safety fuse at input Temperature monitoring of power semiconductors and transformer EMC filters to protect the inverter against RF line interference Monitoring of the DC input for over- and undervoltage Time-dependent switch-off at overload not implemented in K 150 and K 200 devices KACO NEW ENERGY GMBH K SERIES MANUAL

8 5 Installation of the Inverter 5.1 General Information about the Place of Installation Below is a summary of the most important criteria to be observed for an optimal installation environment. The useful life cycle of an inverter is strongly dependent on environmental conditions. The higher the temperature, the shorter is its useful life. Similarly, constant humidity will adversely affect the useful life of an inverter. The ideal place of installation should be dry and air-conditioned. Criteria for an optimal inverter location: The device has been designed for wall-mount installation in indoor areas Do not directly expose the inverter to wetness or humidity Ensure sufficient wire cross-sections depending on the input and output current Installation at eye-level makes it easier to read the LEDs. Ensure accessibility for future service work. Provide a minimum clearance of 100mm above the case, i.e. to other devices, cabinets, ceiling, or similar. Ensure free air circulation around the case and through the heat sink. If the inverter is installed in a switch cabinet or similar enclosure, ensure that heat is carried-off sufficiently, e.g. by means of forced ventilation. The back side of the device and the heat sink can reach a temperature of about 80 C. Important notice: Depending on the type of wall you should use the appropriate screws and dowel pins for fastening the inverter Data referring to the place of installation: Admissible relative air humidity : less than 95% Admissible ambient temperature : C Protection class : IP20 Case/Enclosure material : Aluminum The enclosure is solely made of lightweight aluminum. Therefore, there is no risk of corrosion. KACO NEW ENERGY GMBH K SERIES MANUAL

9 5.2 Mechanical Dimensions Figure Material: Lieferant: Maßstab: 1:1 Toleranz: ISO m Farbe: AlMg3 Pulver RAL 5002 feinstruktur matt xxx Programm: xxx KACO-GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1, Neckarsulm Benennung: K150 4 x Ø4.5 Erstellt Datum: Bearbeiter: Ah Version: V Datei/Teile-Nr: xxx Geprüft/Freigabe Datum: Bearteiter: Art.Nr.: Mechanical dimensions of K 150 and K 200 devices without optional features xxx KACO NEW ENERGY GMBH K SERIES MANUAL

10 Material: Lieferant: Programm: xxx Figure Maßstab: 1:1 Toleranz: ISO m Farbe: 384 AlMg3 Pulver RAL 5002 feinstruktur matt xxx KACO-GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1, Neckarsulm Benennung: K300 4 x Ø6.6 Datum: Mechanical dimensions of K 300 und K 500N devices without optional features Erstellt Bearbeiter: Version: Datei/Teile-Nr: Ah V xxx Geprüft/Freigabe Datum: Bearteiter: Art.Nr.: xxx KACO NEW ENERGY GMBH K SERIES MANUAL

11 Lieferant: xxx Programm: xxx Figure A KACO-GERÄTETECHNIK GmbH Maßstab: 1:1 Toleranz: ISO m Material: AlMg3 Gottfried-Leibniz-Str. 1, Neckarsulm Farbe: Pulver RAL 5002 feinstruktur matt Benennung: A B K 500 AUSGANG EINGANG STÖRUNG K500 Mechanical dimensions of K 500 devices without optional features EIN AUS AUTO 7.2 Erstellt Datum: Bearbeiter: Version: Ah Datei/Teile-Nr: xxx Ø6 V Ø10.3 Geprüft/Freigabe Datum: Bearteiter: Art.Nr.: xxx KACO NEW ENERGY GMBH K SERIES MANUAL

12 Figure Maßstab: 1:1 Toleranz: ISO m Material: AlMg3 Farbe: Pulver RAL 5002 feinstruktur matt Lieferant: xxx Programm: xxx A A K 1000 AUSGANG EINGANG STÖRUNG KACO-GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1, Neckarsulm Benennung: EIN AUS AUTO K1000 Erstellt Datum: Bearbeiter: Version: Datei/Teile-Nr: xxx V Mechanical dimensions of K 1000 devices without optional features 7.2 Ah Ø6 Ø10.3 Geprüft/Freigabe Datum: Bearteiter: Art.Nr.: xxx KACO NEW ENERGY GMBH K SERIES MANUAL

13 Maßstab: Material: Farbe: Lieferant: Programm: xxx Figure 7 1:1 Toleranz: AlMg3 Pulver RAL 5002 feinstruktur matt xxx ISO m K 3000 KACO-GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1, Neckarsulm Benennung: MAINS OUTPUT OUTPUT INV. INPUT FAILURE K x Ø9.0 Mechanical dimensions of K 3000 devices without optional features ON OFF Erstellt Datum: Bearbeiter: Version: Ah Datei/Teile-Nr: xxx V Geprüft/Freigabe Datum: Bearteiter: Art.Nr.: xxx KACO NEW ENERGY GMBH K SERIES MANUAL

14 6 Electrical Connections 6.1 General Information After installing the inverter in a fixed location you may proceed with the electrical connections. The electrical installation of the device must be performed by qualified personnel only. Please observe all relevant safety rules and VDE regulations. Most of the inverters without optional features have their connecting terminals placed inside the device. To perform the electrical connections the cover of the terminal box in the lower part of the enclosure has to be removed. Appropriate PG type or metrical fittings are provided for inserting the leads. Devices with the optional Q feature are provided with the appropriate terminals on the rear side of the case to connect the batteries, AC output leads and remote control switch. On K 150 und K 200 devices the connecting terminals are directly accessible at the bottom side of the enclosure. 6.2 AC Connection The output terminals of the device are marked U, V and PE. Their exact position can vary depending on the type of inverter and the optional features included. Please make sure that the inverter is switched off while connecting the load. 6.3 DC Connection The terminals for the DC leads are marked (+) and (-). Their exact position depends on the type of enclosure and the optional features of the inverter. On K 150 and K 200 devices the DC leads are connected via clamp terminals for wire cross sections up to 4 mm². Starting with the model range K 300 the DC leads are connected via screw terminals which require the use of appropriate terminal ends on the leads. Always make sure not to reverse polarity! This would cause damage to the inverter. Make sure that both the switch on the device itself and the optional remote control switch are in the OFF position while connecting the DC leads. Please ensure sufficient wire cross-sections and keep the connecting lines as short as possible so as to minimize power losses. The wire cross-section depends on the rated input or output current and can be calculated based on the following rule of thumb: 1mm 2 wire cross section for every 5A Therefore, the appropriate wire cross section for 20A is 4mm 2. KACO NEW ENERGY GMBH K SERIES MANUAL

15 6.4 Connecting the Remote Control Switch The terminals for the remote control switch are marked by an appropriate switch symbol. Ideally, a 1-pole switch with two switch positions should be used on K 150 and K 200 devices as well as all inverters without an automatic switch-on mode of operation. A 1-pole switch with three switch positions and a central OFF position should be used for all other devices. The switch must be electrically isolated. The length of the leads between the switch and inverter must not exceed 20m. 7 Inverter Operation After the inverter has been installed mechanically and electrically (see Chapters 5 und 6), you can now switch it on. 7.1 Operation of K 150 and K 200 Inverters K 150 and K 200 inverters are provided with a push-button switch on the front side of the case and three LEDs to indicate the operating status. If the button is pushed for more than 1 second the inverter will switch on or off. LED Display LED LED Color Condition Function OUTPUT green permanently lit up Inverter supplies 230 V AC output voltage INPUT green permanently lit up Input voltage within the permissible range green flashing red permanently lit up Undervoltage red flashing Overvoltage FAILURE red permanently lit up Overtemperature red flashing Overload Remote Control Input voltage within the permissible range device is in remote controlled mode The remote control function is used to enable the inverter by means of an electrically isolated switch. How to connect this switch is described in chapter 6.4 on this page. The push-button switch has priority over the remote control switch. When the device has been switched on by the remote control switch, the input LED is flashing green. If the button is pushed for more than one second, the input LED will be lit continuously and the remote control function is deactivated. If the button is pushed again, the remote control switch will be reactivated, which means that depending on the position of the switch the device will be shut down or continue to run in the remote controlled mode (with the input LED flashing). Modes of Operation If the input or output voltage is not within the permissible voltage range, the microcontroller will shut down the inverter. Now the device checks the input voltage every 10 seconds and restarts as soon as it is within the permissible range. This prevents, for example, total discharge of the storage batteries. In overload and short-circuit error condition the inverter restarts automatically after 10 seconds. If the inverter has shut down because of excess temperature, the device will be restarted after the power stage has cooled down by approx. 10 C. KACO NEW ENERGY GMBH K SERIES MANUAL

16 7.2 Operation of K 300 to K 3000 Inverters The inverter is equipped with a rocker switch with three switch positions (ON, OFF, AUTO) and three LEDs indicating the operating modes. If your inverter is equipped with an internal change-over unit (optional features U1, V1, V2 or V4, see chapter 8.2), the automatic switch-on feature will not be implemented. In this case the switch has only two positions (ON and OFF). Rocker Switch Switch Position ON OFF AUTO LED Display Function of the Inverter Inverter continuously supplies 230 V AC output voltage Inverter is switched off Automatically switches on as soon as the output load is greater than 15W LED LED Color Condition Function OUTPUT green permanently lit up Inverter supplies 230 V AC output voltage green flashing Signals automatic starting mode INPUT green permanently lit up Input voltage within the permissible range red permanently lit up Undervoltage red flashing Overvoltage FAILURE red permanently lit up Overtemperature red flashing Overload Automatic Start If the switch is set to the AUTO position, the inverter will periodically apply 230 V AC to the output every 10 seconds to check if a load of at least 15W is present. If such a load is detected, the device will remain on until this load is removed again. After removing the load the inverter will shut down the output voltage after 10 seconds and start checking for load every 10 seconds, as described above. Remote Control The remote control function is used to enable the inverter by means of an electrically isolated switch. How to connect this switch is described in chapter 6.4 on page 15 If the remote control function is active the rocker switch at the front panel of the inverter must be set to the OFF position. However, it will continue to be active, i.e. even if the remote control switch is connected the inverter can still be switched on or off by means of the front-panel switch. The ON function always has priority over the AUTO function on both the switch on the front panel of the device and the remote control switch. Modes of Operation If the input or output voltage is not within the permissible voltage range, the microcontroller will shut down the inverter. Now the device checks the input voltage every 10 seconds and restarts as soon as it is within the permissible range. This prevents, for example, total discharge of the storage batteries. In overload and short-circuit error condition the inverter restarts automatically after 10 seconds. If the inverter has shut down because of excess temperature, the device will be restarted after the power stage has cooled down by approx. 10 C. KACO NEW ENERGY GMBH K SERIES MANUAL

17 8 Technical Data 8.1 Type Plate Type key K / D Device class Power rating in VA KACO GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1 - D Neckarsulm Device Sine-wave Inverter, PWM technology Type K / D Input 24 V DC Frequency --- Hz Output 230 V AC Frequency 50 Hz Power rating 1000 VA Protection IP 20 Output current 4,35 A AC Iomax 5,22 A AC Load W, L, C Operation continuous Converter circuit symmetrical Mode running Protection class 1 electrically isolated IEC-Norm :1991 EN Serial Number Year 2004 Input voltage in V DC 8.2 Description of Optional Features Output voltage in V AC Optional features A Load controlled activation Device switches off when output power is below 15 VA Device switches on when output power is above 15 VA. C Swiss socket outlet on the front panel of the device (only available in connection with option Q) Socket outlet for Swiss mains plugs (all usual socket outlets available on request) D Railway model (suitable for use on railway vehicles) Includes options R (resistant to mechanical vibrations), K (Device mounted on shock absorbers), E (extended temperature range: - 25 C C), W (extended input voltage range: +35% / -30%) E Extended temperature range - 25 C C (special electronic components) gl Suitable for use on seagoing vessels according to Germanischer Lloyd Includes options E (extended temperature range: - 25 C C), P (suitable for harsh environmental conditions), R (resistant to mechanical vibrations) H With indicating instrument, accuracy class 1,5 (only available in connection with option Q) H1: Analog instrument output current H2: Analog instrument output voltage H3: Analog instrument input current H4: Analog instrument input voltage H5: LED bar graph load indication % H6: Analog instrument resonant reed frequency meter H7: Digital instrument output current H8: Digital instrument output voltage H9: Digital instrument input current H10: Digital instrument input voltage H11: Digital instrument output frequency I All connection terminals inside the device The cover must be removed when setting-up operation. K Device mounted on shock absorbers KACO NEW ENERGY GMBH K SERIES MANUAL

18 M 1 With indication: Inverter failure (potential free change-over contact on terminal) M 2 With Indication: Mains failure only available for devices equipped with an internal change-over unit (options U1, V1, V2, V4) (potential free change-over contact on terminal) M 3 With Indication: Battery supervision (potential free change-over contact on terminal) N Suitable for increased starting current (e.g. motors, cooling units) Different layout of the power stage and current limits P Suitable for harsh environmental conditions Soldered connections, control card with protective coating, anti corrosion measures Q 19" case with perforated plate cover (Protection class IP20) R Resistant to mechanical vibration Includes option K (Device mounted on shock absorbers). S With socket outlet U 1 Integrated relay change-over with inverter priority The output voltage is generated by the inverter. At inverter failure or when leaving the output voltage tolerance range the inverter is disconnected from the output and mains voltage is switched to the output terminals. Includes option M1 (Indication: Inverter failure). Change-over time: up to 1000 VA < 5-20 ms (relay change-over) over 1000 VA < 100 ms (contactor change-over) V 1 Integrated relay change-over with mains priority, inverter in locked-in mode Mains voltage is switched through to the output. At mains failure or, respectively, mains undervoltage the idle running inverter is switched through to the output terminals. Includes options M2 (Indication: Mains failure) and M1 (Indication: Inverter failure). Change-over time: up to 1000 VA < 5-20 ms (relay change-over) over 1000 VA < 100 ms (contactor change-over) V 2 Integrated relay change-over with mains priority, inverter in start-up mode Mains voltage is switched through to the output. At mains failure or, respectively, mains undervoltage the inverter is started and switched through to the output terminals. Includes option M2 (Indication: Mains failure). Interruption time: 2 3 seconds W Extended input voltage range + 35 % / - 30 % The permissible input voltage range is between -30% and +35% of the rated input voltage. (special design of the transformer, modified switching thresholds) X increased insulation test voltage between input and output (>3000Vrms) special insulation of transformers and special construction of the device Z1 English version (manual and type plate in English) Z2 Neutral version (manual and type plate neutral) KACO NEW ENERGY GMBH K SERIES MANUAL

19 8.3 Data Sheet KACO NEW ENERGY GMBH K SERIES MANUAL

20 9 EU Declaration of Conformity The device described below: Sine wave inverter Model: K 150 K 200 K 500N K 1000 K 3000 Power: 150 VA 200 VA 500 VA 1000 VA 3000 VA Input: V DC V DC V DC V DC V DC Output: 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz Is confirmed to be compliant with the protection requirements set forth in The Council Directive for the Harmonization of Legal Stipulations of the Member States concerning Electromagnetic Compatibility (89/336/EWG) and the Low Voltage Regulations (72/23 EWG). The assessment of the product concerning its Electromagnetic Compatibility is based on the following standards: Emitted interference: EN : 1993 Interference resistance: EN : 1997 Harmonics: EN : 1995 Voltage fluctuations and flicker: EN : 1995 The assessment and determination of Electrical Safety is based on the following standard: Semiconductor power converters EN : 1994 EN : 1994 This declaration has been given by KACO GERÄTETECHNIK GmbH Gottfried-Leibniz-Str. 1 D Neckarsulm and authorized by its responsible representative, Matthias Haag Quality Assurance Commissioner Neckarsulm, 30 th August, 2004 KACO GERÄTETECHNIK GmbH i. V. Matthias Haag Quality Assurance Commissioner KACO NEW ENERGY GMBH K SERIES MANUAL

21 10 Warranty and Service Warranty KACO GERÄTETECHNIK GmbH grants a 2-year warranty on inverters, which starts from the date of delivery. Throughout this time KACO NEW ENERGY GmbH will guarantee proper functioning of the device as well as free factory-repair of any defects that we are accountable for. Warranty claims shall not be accepted under the following circumstances: Devices were not used for their intended purpose Improper installation; installation was not carried out in accordance with the relevant standards Improper operation Devices were operated with defective protective features Devices were changed or manipulated by the user External influence or Act of God Insufficient ventilation of the system Non-conformance with valid safety regulations (VDE and others) or Act of God (lightning, overvoltage, tempest, fire) Transport damages Warranty claims must be settled in the factory of KACO ENERGY GmbH. The defective unit(s) must be returned in their original or similar transport packaging. The costs of return shipments cannot be borne by KACO NEW ENERGY GmbH. KACO shall not grant any warranty service unless the defective device has been returned together with a copy of the original invoice. The type label on the device must be fully readable. In the event that these conditions should not be met, KACO shall reserve the right to reject any warranty obligations. The warranty period for rework or replacements shall be 6 months after delivery of the original device, but at least until the end of the original warranty period granted for the delivered device. Service High quality and longevity of our inverters always have been of central importance for us - already at the time of product development. Our more than 60 years of experience in the field of current inverters are backing up this philosophy. Despite all these quality-assuring measures, however, disturbances may occur in very rare cases. KACO NEW ENERGY GmbH will offer a maximum of assistance if one of these cases should arise. KACO NEW ENERGY GmbH will take every effort to remedy any defects fast and without unnecessary bureaucracy. Please contact our service department directly and you will be aided and supported very quickly. For example, you will be able to scheduled fixed dates for factory repair. Moreover, we guarantee the availability of spare parts for 10 years starting from the date of purchase. KACO NEW ENERGY GMBH K SERIES MANUAL

22 11 Troubleshooting and Fault Diagnostics 11.1 Troubleshooting Within the scope of our continuously expanding Quality Assurance System, our goal is to rule out any faults and defects. You have purchased a product that has left our factory in a proper condition. Each individual device has successfully passed extensive inspection tests for their operation and functioning of protective devices, as well as a long-duration test at our factory If your inverter does not work properly despite all these measures, we recommend the following procedure: Check the input and output connections leading to the inverter, observing all safety instructions given in this manual. Please observe the inverter carefully and take note of the display LEDs. If the problem cannot be solved using the methods described in this manual, please contact our Service Department. Please have the following information ready to enable our Service Department to respond quickly and properly: Inverter Data Serial number of the device Inverter type Short description of error Is the error reproducible? If so, please provide a short description. Does the error occur sporadically? 11.2 Transport Damages To ensure high quality and reliability, our inverters are subjected to extensive tests and inspections at our test facility. Our inverters leave our factory in a proper electrical and mechanical condition. Special packaging is used to ensure that nothing can happen during transport. Yet, transport damages are possible, although these damages are usually the carrier s responsibility. Please inspect the inverter carefully after delivery. If you should discover any damages on the packaging which imply damage to the inverter, or if you can state obvious inverter damage, please notify the responsible carrier immediately. If necessary, KACO NEW ENERGY will assist you in this matter. In any case, written damage reports must have been submitted to the carrier within six days after receipt of the goods at the very latest. KACO NEW ENERGY GMBH K SERIES MANUAL

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E Lievers Holland PO Box 103 3640 AC Mijdrecht Tel: +31 (0)297-231900 Fax: +31 (0)297-231909 E-mail: info@lieversholland.nl - www.lieversholland.nl CONTENT

More information

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E Lievers Holland Postbus 103 3640 AC Mijdrecht Tel: +31 (0)297 231900 Fax: +31 (0)297 231909 E mail: info@lieversholland.nl www.lieversholland.nl Operation

More information

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S / / 2013 Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements

More information

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL Table of Contents 1 SAFETY PRECAUTIONS Before use, read the following safety precautions.- 1-1 Explanation of Warning Symbols 001 1-2 Warning Messages for Safe

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

Cable Identifying Generator LCI TX / LCI TX-440

Cable Identifying Generator LCI TX / LCI TX-440 Operation manual Cable Identifying Generator LCI TX / LCI TX-440 Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity Documentation Measurement and Control Type: ELT-GP1 Content 1. Installation instructions 2. Data sheets 3. Declarations of conformity (Part No. 008Q520) eltherm GmbH Ernst-Heinkel-Str. 6-10 57299 Burbach

More information

Radio System Strobe Wizard Plus Freemask

Radio System Strobe Wizard Plus Freemask Radio System Strobe Wizard Plus Freemask User manual Translation of the original German user manual Doc. No.: 900.0509.00 Version: 09/2017 Contents Information about this manual and about the manufacturer...

More information

AC MASTER Switch mode sine wave inverter

AC MASTER Switch mode sine wave inverter USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING MANUEL D UTILISATION / MANUAL DE UTILIZACION / INSTRUZIONI PER L USO AC MASTER Switch mode sine wave inverter Models 12/200, 12/350, 24/200 & 24/350-230V

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-920 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,

More information

OIS25. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

OIS25. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information Optical smart sensor for hydraulic cylinders General Description is a patented smart optical device, which is usually combined with a hydraulic steering cylinder. The main application is on rough terrain

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

ProfiScale MULTI Multimeter

ProfiScale MULTI Multimeter 1,5 V 9V 200 mv 600 V 200 ma 1/10 A ProfiScale MULTI Multimeter en Operating instructions BURG-WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany Introduction Want the reassurance of knowing whether current

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero

More information

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY TT403- K (1000W) Wireless Inline Switch Product Description The TT403- K is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

LED Driver Compact dimming

LED Driver Compact dimming Driver LCAI 35W 350mA 900mA ECO C ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 900 ma Max. output power 35 W Nominal

More information

EN 50178, IEC

EN 50178, IEC Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230

More information

2015 RIGOL TECHNOLOGIES, INC.

2015 RIGOL TECHNOLOGIES, INC. Service Guide DG000 Series Dual-channel Function/Arbitrary Waveform Generator Oct. 205 TECHNOLOGIES, INC. Guaranty and Declaration Copyright 203 TECHNOLOGIES, INC. All Rights Reserved. Trademark Information

More information

Commissioning and Maintenance of Power Factor Correction Systems

Commissioning and Maintenance of Power Factor Correction Systems Dear Customer, We would like to thank you for choosing a power factor correction system from FRAKO Kondensatoren- und Anlagenbau GmbH. It is a pleasure to welcome you into the ever-expanding circle of

More information

LED Driver Compact dimming

LED Driver Compact dimming Driver LCAI 35W 3mA 900mA ECO C flat ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 3 900 ma Max. output power 35 W Nominal

More information

Digital Function Generator

Digital Function Generator Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions

More information

QL55 Series Luminescence Sensor

QL55 Series Luminescence Sensor Self-contained, microprocessor-based luminescence sensor Features Self-contained design in a robust, compact metal housing High sensitivity Microprocessor-controlled Senses luminescent marks, even on luminescent

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

TS-700/1000 INVERTER Instruction Manual

TS-700/1000 INVERTER Instruction Manual TS-700/1000 INVERTER Instruction Manual TS-700/1000 Instruction Manual Index 1. Safety Guidelines... 1 2. Introduction... 1 2.1 Features... 1 2.2 Main Specification... 2 3. User Interface... 2 3.1 Front

More information

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5. Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...

More information

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series EL Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 150 400 ma Max. output power 20 W Nominal life-time up to 100,000 h 5-year guarantee

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

TT W Wireless receiver Inline Switch

TT W Wireless receiver Inline Switch TT403 1000W Wireless receiver Inline Switch Product Description The TT403 is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 350 900 ma Max. output power 20 W Nominal life-time up to 100,000 h 5-year guarantee Dimming

More information

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 55 W Nominal life-time up to 100,000 h 5-year guarantee

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

E N G I N E E R I N G M A N U A L

E N G I N E E R I N G M A N U A L 1 1 1.0 PURPOSE The purpose of this document is to define policy and provide engineering guidelines for the AP operating companies (Monongahela Power Company, The Potomac Edison Company, and West Penn

More information

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI Circuit Analyzer Operation S Manual MS5908A L - N L - E N - E Peak Z - L Z - N Z - E ASCC AC TEST N[] [] L E ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA Ω% V Vd Z RCD GFCI MS5908A General Instructions This

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Pure sine wave inverter USER S MANUAL

Pure sine wave inverter USER S MANUAL USER S MANUAL INV10120700 / INV20120700 / INV30120700 INV10121000 / INV20121000 / INV10121500 INV20121500 / INV30121500 / INV10240700 INV20240700 / INV10241000 / INV10241500 INV20121500 Pure sine wave

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

MASTECH MS5908. Circuit Analyzer

MASTECH MS5908. Circuit Analyzer MASTECH MS5908 Circuit Analyzer Operation Manual 2 General Instructions This circuit analyzer is a special test device designed for AC low-voltage distribution line quick fault location. With simple operation,

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009 User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent

More information

Analog amplifier RA. RE Edition: Replaces:

Analog amplifier RA. RE Edition: Replaces: Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable

More information

Orbital GFI Inverter Series

Orbital GFI Inverter Series Orbital GFI Inverter Series Datasheet Key Features One, split or three phases and up to 25 kva Superior efficiency of 95% CAN Bus control and DAQ Power quality and EMC compliance in accordance with European

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Installation and Operating Instructions. Power IT Power Factor Controller RVC Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...

More information

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS SAUDI STANDARD NO. SASO IEC 60669-2-2: 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS Part 2-2: Particular requirements Electromagnetic remote-control switches (RCS) SAUDI ARABIAN

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ESP Product Warranty Zener Electric warrant the Electronic Shear Pin against defective workmanship and materials for a period of 24 months from the

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series Driver LC 100W 24V lp SNC ESSENCE series Product description LED Driver Output voltage 24 V Max. output power 100 W Dimmable via PWM LED dimmers Nominal life-time up to 50,000 h 5-year guarantee Typical

More information

LED Driver Constant voltage. Driver LC 60W 24V lp SNC ESSENCE series

LED Driver Constant voltage. Driver LC 60W 24V lp SNC ESSENCE series Driver LC 60W 24V lp SNC ESSENCE series Product description LED Driver Output voltage 24 V Max. output power 60 W Dimmable via PWM LED dimmers Nominal life-time up to 50,000 h 5-year guarantee Typical

More information

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 550 ma Max. output power 20 W Nominal life-time up to 100,000 h 5-year guarantee

More information

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series Udriver LCAI 20W 350mA 550mA ECO lp ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 550 ma Max. output power 20 W Nominal

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Level Switch NRS 2-50 NRS Original Installation Instructions English

Level Switch NRS 2-50 NRS Original Installation Instructions English Level Switch NRS 2-50 NRS 2-51 EN English Original Installation Instructions 819179-03 1 Contents Important Notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and Standards

More information

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau Reactive Power Control Relay RM 2106 / 2112 Operating Instructions FRAKO Kondensatoren- und Anlagenbau www.frako.com Figure 1 Front view a b c d e Display for active capacitor stages Display for inductive

More information

ECM3 EARTH CONTINUITY RELAY

ECM3 EARTH CONTINUITY RELAY TECHNICAL DATASHEET ECM3 EARTH CONTINUITY RELAY Electrical Protection for Hard Rock Mines Application The ECM3 has been designed to provide earth continuity protection for cables containing pilot cores.

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 30 900 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam User Manual SBeamRep-BEN091911 98-0002611 Version 1.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 15 4 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

LED Driver Linear / area dimming

LED Driver Linear / area dimming EL Udriver LCAI 35W 900mA 1750mA ECO lp ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power

More information

Operating manual. TruTool N 500 (1A1) english

Operating manual. TruTool N 500 (1A1) english Operating manual TruTool N 500 (1A1) english Table of Contents 1. Safety...4 1.1 General safety information...4 1.2 Specific safety information...5 2. Description...6 2.1 Correct use...7 2.2 Technical

More information

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New) XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Original operating instructions Fail-safe inductive sensor GG507S

Original operating instructions Fail-safe inductive sensor GG507S Original operating instructions Fail-safe inductive sensor GG507S 80236827 / 00 09 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Digital Multimeter E 1018832 Instruction sheet 12/16 SD/UD 1 probe 1a Finger guards 2 Measurement socket 10 A for current measurement in 10-A (positive) 3 Measurement socket COM (negative)

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

basicdim Wireless basicdim Wireless LED Drivers

basicdim Wireless basicdim Wireless LED Drivers LED Drivers Driver LC 35W 24V bdw SC PRE2 premium series constant voltage Product description Dimmable 24 V constant voltage LED Driver for flexible constant voltage strips enables different dimming options

More information

Operating Instructions K-POWERgrip EWL Always on the safe site.

Operating Instructions K-POWERgrip EWL Always on the safe site. Operating Instructions K-POWERgrip EWL 4941. Always on the safe site. KaVo Elektrotechnisches Werk GmbH Wangener Straße 78 D-88299 Leutkirch A 1 User information...2 A 1.1 Meaning of the pictograms...2

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series Driver LC 100W 24V lp SNC ESSENCE series Product description LED Driver Output voltage 24 V Max. output power 100 W Dimmable via PWM LED dimmers Nominal life-time up to 50,000 h 5-year guarantee Typical

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

BROADBAND LINEAR AMPLIFIER Model P150

BROADBAND LINEAR AMPLIFIER Model P150 ELECTRONICS AB BROADBAND LINEAR AMPLIFIER Model P150 HIGH VOLTAGE GAIN HIGH CURRENT +150V 20x 1A HIGH POWER SMALL SIGNAL SLEW RATE BANDWIDTH BANDWIDTH 30 V/µs DC to ca 60 khz DC to >200 khz FLC Electronics

More information

Thank you for purchasing a qualiton A20i power amplifier!

Thank you for purchasing a qualiton A20i power amplifier! Introduction Thank you for purchasing a qualiton A20i power amplifier! It is designed to deliver a high standard of musical performance. The innovation in engineering and manufacturing this product guarantees

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 350 900 ma Max. output power 35 W Nominal life-time up to 100,000 h For luminaires of protection

More information

Installation and Operating Instructions for Phase Demodulator Type _.2

Installation and Operating Instructions for Phase Demodulator Type _.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)

More information

XUA1 - AC Voltage and phase balance relay

XUA1 - AC Voltage and phase balance relay XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of

More information