Ref no.a2/73/17/mec dtd Tender No.6/ /MEC

Size: px
Start display at page:

Download "Ref no.a2/73/17/mec dtd Tender No.6/ /MEC"

Transcription

1 Sheet Ref no.a/73/7/mec dtd Tender No.6/06-7/MEC SL No Item Specification Qty Analog type Portable Ammeters AC/DC Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0-.5/5A, MI 0% and 00% of scale Analog type Portable Voltmeters AC/DC Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0-50V, MI 0% and 00% of scale 3 Rheostat Single Tube Open type Resistance wire wound sliding rheostats on vitreous enameled drawn hexagonal steel tube, fitted with self lubricating copper graphite brush with pigtail connections and Bakelite Knob with good finger grip for smooth operation, and with two end castings insulated with micanite cups. Tolerance on resistance value : + 0% to -5% H.T. Test : kv for minute Maximum working voltage : 500 V 50ohm, 5A (.5" x 0") 4 Wattmeter (Dynamometer type) Page

2 Sheet ph wattmetr (lpf) 5/0A, 75/50/300V;Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of ph., 50/500V, 5/0A, lpf scale phase, 50V, 0A, Electromechanical Induction 5 Energymeter type Clamp- on Ammeter 40A, 6 Clamp- on Ammeters TRMS, Digital Display Page

3 Digital Multimeter Sheet LCD Display with Automatic Polarity & Zero Adjustment, Over range indication, OL protection & Low Battery Indication, DC Voltage: 400mV/4/40/400/000V, Accuracy All range ± (0.5% rdg + dgt), Resolution : 00mV to V 0M ohm Input Impedance. AC Voltage 400mV/4/40/400/750V Accuracy : 400mV- 400V ±(.0% rdg +4 dgt), 750V ±(.5% rdg +4 dgt), Resolution : 00mV to V DC Current 40mA/400mA/0A, Accuracy : 0A range ± (.0% rdg + 3 dgt), Other ranges ± (.0% rdg + dgt) OL Protection : 0A input, Unfused, upto A for 30Sec, Other ranges Input. 0.8A/50V fuse AC Current 40mA/400mA/0A, Accuracy ± 0A range ± (.0% rdg + 4 dgt), Other ranges ± (.% rdg + 4 dgt) OL Protection : 0A input, Unfused, upto A for 30Sec, Other ranges Input. 0.8A/50V fuse Resistance 400ohm/4/40/400kohm/4/40/ 400Mohm, Capacitance 4/400/400nF/4/40Micro F, Accuracy ± (3.0% rdg + 0 dgt), Test frequency : 400Hz, Test Voltage : 50mV, Resolution : pf to 0nF Frequency : Auto Range (4K- MHz),Accuracy ± (% rdg + dgt), OL Protection : 500VAC/DC 7 Digital with LCD Display, 8 Stop Watch Accuracy ± % Page 3

4 Sheet KVA Off-Line HYKON UPS,HYKON- phase AC input & single phase AC output, Floor Mounted,Rating of UPS: 3.0KVA,Indicative Back- 9 UPS up time: 30 Minutes 3-phase, 45V,0A, Electromechanical Induction type / Energy meter 0 Electronic type The trainer kit consists of the following built-in parts : 0. Schering Bridge circuit with arms values. 0. ± VDC at 00 ma, IC Regulated Power Supply internally connected. 03. KHz Sinewave oscillator having output 0-5 Vpp. 04. Audio amplifier and speaker for null detector. 05. Three unknown value of capacitors selectable by a band switch. 06. Potentiometer for balancing the bridge. 07. Band switch to select one from six different values of resistance. 08. Adequate no. of other Electronic Components. 09. Mains ON/OFF switch, Fuse & Jewel light. * The unit is operative on 30V ±0% at 50Hz AC Mains. * Adequate no. of patch cords stackable Schering Bridge trainer kit 4mm spring loaded plug length / metre. 000V, with in-built hand Meggar driven generator Testing Kit for 000V Earth 3 Earth Tester Kit tester 4 Power Factor Meter Dynamometer type Page 4

5 Sheet Measuring range : 03, 04 and 05Kilomaxwell turns with 00 % over range protection. Indication : 3 / digit panel meter with mm LED. Resolution : Kilo maxwell turn. Accuracy : ± 0.5 % of full scale. Input Resistance : 0 Kilo Ohms. Drift : Less than 0.5% of full scale per minute on 0'Kilomaxwell turns range. Output Voltage : Kilomaxwell turns range. Input Power : 40 V, 50 Hz, 5 V Output Resistance : Kilo 5 Magenetic Flux Meter Ohms 6 7 Operating Modes : Normal & Differential CH I, CH II, CH I and CH II, ALT, CHOP, ADD, DIFF, XY Vertical Deflection Power Scope Defelction Coeff. 5mv/div -0v/div, Accuracy ±%, Bandwidth 30 Mhz, Rise time.6 ns, Attenuation :0, :00, Input impedance Normal Mo Frequency Range 0.3 Hz to 3 Mhz, Sine, square, triangle wave, variable duty cycle, pulse & ramp, Power Input 30 V±5%, External Voltage Function Generator Controlled Frequency (VCF) Function Duty Cycle Control with Signal Inversion Capability Variable DC Offset Control Built-In 6 Digit Counter AM/FM Modulation DC power supply 0- ±v, A, adjustable by means of coarse & fine controls, Input voltage 30V + 0%, 50 Hz, Ripple Voltage Less than 3mV rms, digital meters for current and voltage, 7 segment LED type dsipaly, meter Accuracy : ±( % + digit), Protection against short circuit and continuous overlaods 8 Page 5

6 Sheet 9 0 Single phase transformer Voltmeter(MC) 0-00V Ammeter(MC) 0-50/500microA 50 VA, 30/ V, 50 Hz, center tapped, CRGO core, air cooled with enclosure, terminals to be taken out for connection(laboratory type) Moving Coil DC Voltmeter 0-00V. Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of scale Moving Coil DC Ammeter 0-50/500microA Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of scale Single Tube Open type Resistance wire wound sliding rheostats on vitreous enameled 500 ohm,.a(" x 6") drawn hexagonal steel tube, fitted with self lubricating copper graphite brush with pigtail connections and Page 6

7 Sheet LCD Display with Automatic Polarity & Zero Adjustment, Over range indication, OL protection & Low Battery Indication, DC Voltage: 400mV/4/40/400/000V, Accuracy All range ± (0.5% rdg + dgt), Resolution : 00mV to V 0M ohm Input Impedance. AC Voltage 400mV/4/40/400/750V Accuracy : 400mV- 400V ±(.0% rdg +4 dgt), 750V ±(.5% rdg +4 dgt), Resolution : 00mV to V DC Current 40mA/400mA/0A, Accuracy : 0A range ± (.0% rdg + 3 dgt), Other ranges ± (.0% rdg + dgt) OL Protection : 0A input, Unfused, upto A for 30Sec, Other ranges Input. 0.8A/50V 3 Digital Multimeter fuse AC Current 40mA/400mA/0A, Accuracy ± 0A range ± (.0% rdg + 4 dgt), Other ranges ± (.% rdg + 4 dgt) OL Protection : 0A input, Unfused, upto A for 30Sec, Other ranges Input. 0.8A/50V fuse Resistance 400ohm/4/40/400kohm/4/40/40 0Mohm, Capacitance 4/400/400nF/4/40Micro F, Accuracy ± (3.0% rdg + 0 dgt), Test frequency : 400Hz, Test Voltage : 50mV, Resolution : pf to 0nF Frequency : Auto Range (4K- MHz),Accuracy ± (% rdg + dgt), OL Protection : 500VAC/DC ph (upf) Wattmeter 5/30A,5/50/500V; Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 4 Wattmeter 0 Megohms at 500V Page 7

8 Sheet 0-5/50V(MI); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 5 Voltmeter(MI) scale 4 0-5/30V(MI); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 6 Voltmeter(MI) scale /00 V(MC); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 7 Voltmeter(MC) scale 0-50/300V(MC); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 8 Voltmeter(MC) scale 4 0-5/0A(MI); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 9 Ammeter(MI) scale 3 0-5/30A(MI); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 30 Ammeter(MI) scale Page 8

9 Sheet 0-/A(MI); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 3 Ammeter(MI) scale 0-.5/5A(MC); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 3 Ammeter(MC) scale 0-5/0A(MC); Scale length:40mm,test Voltage:000V AC (rms) for minute, Insulation Resistance 0 Megohms at 500V DC. Rated Accuracy: Class.0 (% of full scale value) as per ISS 48/84, between 0% and 00% of 33 Ammeter(MC) scale 500ohm,.A;Single Tube Open type Resistance wire wound sliding rheostats on vitreous enameled drawn hexagonal steel tube, fitted with self lubricating copper graphite brush with pigtail connections and Bakelite Knob with good finger grip for smooth operation, and with two end castings insulated with micanite cups. Tolerance on resistance value : + 0% to -5% 34 Rheostat H.T. Test : kv for minute 3 Maximum working voltage : 500 V 35 Loading rheostat 5kW, 440V x ft multi purpose platform 36 Trolley trolley Page 9

10 Sheet Page 0

11 Sheet Computers Intel core Duo, 3.4 GHz/4GB RAM/500 GB HDD/DVD/8.5 Desk top computer with " preloaded 3, operating system LED/Keyboard/ Mouse, USB ports, operating system Microsoft windows 0 The no of computers presently available are insufficient for conducting regular labs.. More over, for doing main projects also more systems are required. Page

12 Sheet3 Furniture requirement Anticipated expenditure Sl.No Item specification Qty Justification Rate (Rs) Amount (Rs) Vendor Steel cabinet Annexure IV with 4 fixed item (sidco shelves list) (78 x36 x9 ) (G)64 kg Very essential in the department for faculty / HOD to keep documents. 4 Steel table with Annexure a 3 drawers, one drawer and cupboard on right side with novopan top Anjili wood computer table 90x60x75 cm with sliding key board and laminated plywood for top and keyboard V item 0 (sidco list) Annexure item 5 (sidco list) Not sufficient 3 tables in the department/ lab for faculty Currently 9 nos but not sufficient to keep 5 computersalread y available plus computers proposed now and 3 numbers in the staff room SIDCO,Kerala state 5 Full arm chair with plastic seat and back, ordinary wood, steel pipe 6 Mtr Annexure IV item (sidco list) Urgently 5 required in labs and staff room K Page

MINUTES OF PRE BID MEETING

MINUTES OF PRE BID MEETING MINUTES OF PRE BID MEETING Tender for Supply, Delivery, Installation & Commissioning of Equipment for Department of Engineering Technology, Faculty of Technological Studies Tender No : UWU/AHEAD/18/TS/ET/02

More information

RAJKIYA ENGINEERING COLLEGE, KANNAUJ

RAJKIYA ENGINEERING COLLEGE, KANNAUJ RAJKIYA ENGINEERING COLLEGE, KANNAUJ Tender No.: 23/EE/RECM/SPS/2016 Dated: 13.07.2016 due on 03.08.2016 by 1:30 pm Schedule 01 Laboratory Technical Specification / Model Details Qty. Electrical Complete

More information

ELECTRICAL MEASUREMENTS

ELECTRICAL MEASUREMENTS R10 Set No: 1 1. a) Derive the expression for torque equation for a moving iron attraction type instrument and comment up on the nature of scale [8] b) Define the terms current sensitivity, voltage sensitivity

More information

Green LED (right of 'D' type connector)

Green LED (right of 'D' type connector) 3050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interfaces USB Optional Interfaces GPIB (IEEE-488) : RS232

More information

BASIC ELECTRICAL LAB EQUIPMENTS

BASIC ELECTRICAL LAB EQUIPMENTS BASIC ELECTRICAL LAB EQUIPMENTS S No. Name of the Equipment Qty Model/Specification Superposition theorem kit(s) 0 Jupiter Norton's theorem kit(s) 0 Jupiter 3 Thevenin theorem kit(s) 0 Jupiter 4 Maximum

More information

MEASUREMENTS & INSTRUMENTATION ANALOG AND DIGITAL METERS

MEASUREMENTS & INSTRUMENTATION ANALOG AND DIGITAL METERS MEASUREMENTS & INSTRUMENTATION ANALOG AND DIGITAL METERS ANALOG Metering devices Provides monotonous (continuous) movement. ELECTRICAL MEASURING INSTRUMENTS ANALOG METERS A d Arsonval galvanometer (Moving

More information

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications FUNCTION GENERATOR EAN CODE : 3760244880468 5 MHZ+RS232++(USB or LAN)* GF 467F COMPLETE : Reciprocal frequency counter 50 MHz. - Internal linear or logarithmic sweep, and external VCF or FM modulation.

More information

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR MODEL 9050 EXTENDED SPECIFICATIONS Ü 50ppm TRANSPORTABLE CALIBRATOR 9050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

Item Name & Package Code Specifications Quantity Last Date & Time of Submission of Quotation

Item Name & Package Code Specifications Quantity Last Date & Time of Submission of Quotation Quotation should be addressed to the Registrar, HBTU, Kanpur, Uttar Pradesh-208002. The envelope should be super scribed with Quotation for TEQIP-III, Package Name (As Applicable). Quotation are invited

More information

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505 OTHER PRODUCTS.. Multi-function Gain-Phase Analyzer ( Response Analyzer) Model 2505 Standard Configurations Gain phase analyzer response analyzer Phase Angle Voltmeter (PAV) Fast dual channel wide-band

More information

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes United States Home >... > Oscilloscope Accessories > U1600 Series Oscilloscope Accessories > U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes Key Specifications Features Ni-MH Battery Pack,

More information

Code No: RR Set No. 1

Code No: RR Set No. 1 Code No: RR310202 Set No. 1 III B.Tech I Semester Regular Examinations, November 2006 ELECTRICAL MEASUREMENTS (Electrical & Electronic Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions

More information

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA Técnicas para la calibración de medidores analógicos Bill Gaviria Regional Product Manager Direct: +1.425.446.5335 Cell: +1.321.626.7845 Email: bill.gaviria@flukecal.com

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product

More information

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator An all-new handheld oscilloscope-hantek2000 series, it continues the compact and lightweight concept but with a new generation of 3 in 1 multifunction

More information

Logic Gates & Training Boards

Logic Gates & Training Boards Logic Gates & Training Boards ANALOG TO DIGITAL (A/D) CONVERTOR (ELP.112.140) Objective : To study Analog to Digital & Digital to Analog convertors using R-2R network & Successive Approximation Method.

More information

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources. 3 Channel Digital Storage Oscilloscope (DSO) Instrument VERTICAL SPECIFICATIONS Analogue Bandwidth (-3dB) Bandwidth Limiting Rise time (10% to 90%, calculated) Input ranges (full scale) Input sensitivity

More information

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR MODEL 9041 EXTENDED SPECIFICATIONS 25ppm TRANSPORTABLE CALIBRATOR 9041 EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1. DIGITAL MULTIMETERS Model M-1700 Model M-2775 Frequency to 20MHz Diode and Transistor Test AC/DC Current to 10A Three Way Overload Protection Extra Large 1 display test Data Hold Frequency to 20MHz Transistor

More information

Calibration Techniques for the Home Lab

Calibration Techniques for the Home Lab Calibration Techniques for the Home Lab Jacques Audet VE2AZX jacaudet@videotron.ca Web: ve2azx.net September 2018 ve2azx.net 1 Summary - Using a reference multimeter as a calibrator for less accurate instruments.

More information

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

R & D Electronics DIGITAL IC TRAINER. Model : DE-150. Feature: Object: Specification:

R & D Electronics DIGITAL IC TRAINER. Model : DE-150. Feature: Object: Specification: DIGITAL IC TRAINER Model : DE-150 Object: To Study the Operation of Digital Logic ICs TTL and CMOS. To Study the All Gates, Flip-Flops, Counters etc. To Study the both the basic and advance digital electronics

More information

No.A2/353/2012/MPTC 04/01/2013 MODEL POLYTECHNIC COLLEGE (Managed by IHRD) Mattakkara P. O, Kottayam (Dt.) TENDER NOTICE

No.A2/353/2012/MPTC 04/01/2013 MODEL POLYTECHNIC COLLEGE (Managed by IHRD) Mattakkara P. O, Kottayam (Dt.) TENDER NOTICE No.A/33/0/MPTC 04/0/03 MODEL POLYTECHNIC COLLEGE (Managed by IHRD) Mattakkara P. O, Kottayam (Dt.) 686 64 Phone 048 40,8470008 TENDER NOTICE Sealed Competitive Tenders in the prescribed forms are invited

More information

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization The University of Jordan Mechatronics Engineering Department Electronics Lab.(0908322) Experiment 1: Lab Equipment Familiarization Objectives To be familiar with the main blocks of the oscilloscope and

More information

FUNCTION GENERATOR OPERATION MANUAL

FUNCTION GENERATOR OPERATION MANUAL FUNCTION GENERATOR OPERATION MANUAL INDEX 1. Introduction (3) 2. Specifications (3) 3. Working Theory (7) 4. Structure (8) 5. Operation & Maintenance (9) 6. Accessories (14) 1 This instrument is a highly

More information

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1 Digital Multimeters ON / OFF power switch Continuity / Diode Test Function Resistance Function Ranges from 200Ω to 200MΩ Transistor Test Function DC Current Function Ranges from 2mA to 20A. AC Current

More information

U1604A Handheld Oscilloscopes, 40 MHz

U1604A Handheld Oscilloscopes, 40 MHz Products & Services Technical Support Buy Industries About Agilent Search: All Test & Measurement Go United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1604A Handheld

More information

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR (AUTONOMOUS) Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR (AUTONOMOUS) Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE) SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR (AUTONOMOUS) Siddharth Nagar, Narayanavanam Road 517583 QUESTION BANK (DESCRIPTIVE) Suject : Electrical & Electronic Measurements(16EE224) Year & Sem: III-B.Tech

More information

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning SENSORS AND TRANSDUCERS TRAINER IT.MLD900 The s and Instrumentation Trainer introduces students to input sensors, output actuators, signal conditioning circuits, and display devices through a wide range

More information

Calsytech, # 38 North Mada Street Nandambakkam, Chennai, Tamil Nadu. Discipline Electro-Technical Calibration Issue Date

Calsytech, # 38 North Mada Street Nandambakkam, Chennai, Tamil Nadu. Discipline Electro-Technical Calibration Issue Date Last Amended on 23.11.2016 Page 1 of 7 SOURCE 1. DC VOLTAGE $ 1mV to 10 mv 10 mv to100 mv 100 mv to1000 V 0.43% to 0.05% 0.05% to 0.01% 0.01% to 0.004% Calibrator, Calibrator by DC VOLTAGE 1mV to 20 mv

More information

GAMMA 10 DIGITAL MULTIMETER

GAMMA 10 DIGITAL MULTIMETER Gamma 10 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

HP-3310B 20M Colored Handheld Oscilloscope

HP-3310B 20M Colored Handheld Oscilloscope HP-3310B 20M Colored Handheld Oscilloscope 20M digital storage oscilloscope (DSO) Combination of a 4000 count auto-range True RMS DMM DMM functions include True RMS AC/DC voltage and current, resistance,

More information

High Votage Module AC/DC/Impulse Test System

High Votage Module AC/DC/Impulse Test System TSGADI Series High Votage Module AC/DC/Impulse Test System A digital control and measuring system is used to be control the difference output AC/DC/Impulse and related protection device such as over voltage

More information

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS www. transmille.com 3010A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last

More information

2-channel models. 4-channel models

2-channel models. 4-channel models 2-channel models DSO1052B DSO1072B DSO1102B DSO1152B 50 MHz 70 MHz 100 MHz 150 MHz 4-channel models DSO1004A DSO1014A DSO1024A 60 MHz 100 MHz 200 MHz DSO1022A 200 MHz Segment 1 Segment 2 Segment 1000

More information

S.No Description/Specifications Qty 01. Post office box Trainer.

S.No Description/Specifications Qty 01. Post office box Trainer. Specification of Equipments for Physics lab S.No Description/Specifications Qty 01. Post office box Trainer. 06 The trainer should have: On Board DC Power Supply : 5V Galvanometer ; Deflection : 30 0 30

More information

Radio and Electronics Fundamentals

Radio and Electronics Fundamentals Amateur Radio License Class Radio and Electronics Fundamentals Presented by Steve Gallafent September 26, 2007 Radio and Electronics Fundamentals Voltage, Current, and Resistance Electric current is the

More information

SUBJECT TO CHANGE WITHOUT NOTICE

SUBJECT TO CHANGE WITHOUT NOTICE www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters ijunior / JUNIOR Current Transformers Analogue Panel Meters

More information

TENDER NOTICE Sealed tenders affixed with revenue stamp of Rs. 5/- are invited for and on behalf of Vice Chancellor, Islamic University of Science &

TENDER NOTICE Sealed tenders affixed with revenue stamp of Rs. 5/- are invited for and on behalf of Vice Chancellor, Islamic University of Science & TENDER NOTICE Sealed tenders affixed with revenue stamp of Rs. 5/- are invited for and on behalf of Vice Chancellor, Islamic University of Science & Technology(IUST), Awantipora from OEM/Authorized Dealers/Distributors

More information

APPA 300 Series. The Most User-Friendly High Performance Multimeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"

More information

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION An ISO 9001:2008 Company 2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION SPECIAL FEATURES : 2000A AC Clamp-on + Full Multimeter ranges AC True RMS Voltage & Current functions Autocheck

More information

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14 Table of Contents Table of Contents Instrumentation Multimeter 1 2 2 Lucas Nülle GmbH Page 1/14 www.lucas-nuelle.com Instrumentation Robust, educational and industrial measuring equipment for electrical

More information

MODEL POLYTECHNIC COLLEGE KARUNAGAPPALLY Ph: TENDER NOTICE

MODEL POLYTECHNIC COLLEGE KARUNAGAPPALLY Ph: TENDER NOTICE MODEL POLYTECHNIC COLLEGE KARUNAGAPPALLY Ph: 0476-2623597 TENDER NOTICE Superscription.-Tender No :- P/549(19)/2014-15 for Purchasing of Power Supply Due date and time for receipt of tender. 29.04.2014

More information

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual Item ref: 600.104UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. WARNING

More information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating

More information

Specifications. Specifications and Characteristics Specifications

Specifications. Specifications and Characteristics Specifications Specifications and Specifications Specifications All specifications are warranted. Specifications are valid after a 30-minute warm-up period and ±5 C from last calibration temperature. Bandwidth (-3dB)

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications Sefram SEFRAM Make sure to visit our Website http://wwwseframfr A new family of paperless recorders 6 to 72 channels, to cover all your applications 6 to 72 analogue channels Measurement boards : - 6 isolated

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

Electrical And Electronics Engg

Electrical And Electronics Engg Electrical And Electronics Engg Rectifier Cubical panel type Voltage 3Ph 440V /(0-300V) DC 3Ph Isolation transformer-20kva Thyristor rating Current -300A/PIV - 1500V over load protection and necessary

More information

CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO).

CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO). 1. 1 To study CRO. CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO). Apparatus: - C.R.O, Connecting probe (BNC cable). Theory:An CRO is easily the most useful instrument available for testing

More information

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation EECE208 INTRO To ELECTRICAL ENG LAB Dr. Charles Kim LAB 2. Instrumentation Objectives A brief description of the equipment (Oscilloscope, Function Generator, Power Supply, and Digital Multimeter) and its

More information

Bhoj Reddy Engineering College for Women, Hyderabad Department of Electronics and Communication Engineering Electrical and Electronics Instrumentation

Bhoj Reddy Engineering College for Women, Hyderabad Department of Electronics and Communication Engineering Electrical and Electronics Instrumentation Bhoj Reddy Engineering College for Women, Hyderabad Department of Electronics and Communication Engineering Electrical and Electronics Instrumentation Academic Year: 2016-17 III B Tech II Semester Branch:

More information

Chino Scientific Instruments Manufacturing

Chino Scientific Instruments Manufacturing DIGITAL MICRO OHM METER Chino s made DIGITAL MICRO OHM METER is a compact high reliability 3 ½ digit instrument suitable for measurement of resistivity of copper wires from 70 SWG to 50 SWG resistance

More information

MODEL: D03128 CLAMP METER

MODEL: D03128 CLAMP METER MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications

More information

Using Circuits, Signals and Instruments

Using Circuits, Signals and Instruments Using Circuits, Signals and Instruments To be ignorant of one s ignorance is the malady of the ignorant. A. B. Alcott (1799-1888) Some knowledge of electrical and electronic technology is essential for

More information

EE ELECTRICAL ENGINEERING AND INSTRUMENTATION

EE ELECTRICAL ENGINEERING AND INSTRUMENTATION EE6352 - ELECTRICAL ENGINEERING AND INSTRUMENTATION UNIT V ANALOG AND DIGITAL INSTRUMENTS Digital Voltmeter (DVM) It is a device used for measuring the magnitude of DC voltages. AC voltages can be measured

More information

COURSE PLAN

COURSE PLAN COURSE PLAN 26-27 Staff Name: DR S.M.SHASHIDHAR Sem:III q Sec:A Course Name: ELECTRICAL AND ELECTRONIC MEASUREMENTS Lesson plan author name: DR S.M.SHASHIDHAR Course Code:15EE36 Checked by: Total Contact

More information

Introduction to Basic Laboratory Instruments

Introduction to Basic Laboratory Instruments Introduction to Contents: 1. Objectives... 2 2. Laboratory Safety... 2 3.... 2 4. Using a DC Power Supply... 2 5. Using a Function Generator... 3 5.1 Turn on the Instrument... 3 5.2 Setting Signal Type...

More information

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual Cycle 2 EE652 Electrical Machines II Lab Manual CIRCUIT DIAGRAM FOR SLIP TEST 80V DC SUPPLY 350Ω, 2 A 3 Point Starter L F A NAME PLATE DETAILS: 3Ф alternator DC shunt motor FUSE RATING: Volts: Volts: 25%

More information

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000 STS 4000 Multifunction substation maintenance & commissioning test system for current, voltage and power transformers. Capacitance / Tan Delta diagnostic system with the optional module TD 5000. w w w.

More information

Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET

Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET LABORATORY MANUAL EXPERIMENT NO. ISSUE NO. : ISSUE DATE: REV. NO. : REV. DATE : PAGE:

More information

i Intelligent Digitize Emulated Achievement Lab

i Intelligent Digitize Emulated Achievement Lab Electronics Circuits Equipment Intelligent Digitize Emulated Achievement Lab intelligent digitize emulated achievement lab is a digitized-based training system, which utilizes integrated Hardware Platform,

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

Type Ordering Code Package TDA Q67000-A5168 P-DIP-18-5

Type Ordering Code Package TDA Q67000-A5168 P-DIP-18-5 Video Modulator for FM-Audio TDA 5666-5 Preliminary Data Bipolar IC Features FM-audio modulator Sync level clamping of video input signal Controlling of peak white value Continuous adjustment of modulation

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor)

Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor) 72 Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor) Equipment List Qty Items Part Numbers 1 PASCO 750 Interface 1 Voltage Sensor CI-6503 1 AC/DC Electronics Laboratory EM-8656 2 Banana

More information

GAMMA 12 DIGITAL MULTIMETER

GAMMA 12 DIGITAL MULTIMETER Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTOMOTIVE MULTIMETER MODEL QM1444 the finger guards on the probes. Measuring voltage which exceeds the limits of the multimeter may damage the meter and expose the operator to a

More information

Multiple Instrument Station Module

Multiple Instrument Station Module Multiple Instrument Station Module Digital Storage Oscilloscope Vertical Channels Sampling rate Bandwidth Coupling Input impedance Vertical sensitivity Vertical resolution Max. input voltage Horizontal

More information

ANALOG AND DIGITAL INSTRUMENTS

ANALOG AND DIGITAL INSTRUMENTS ANALOG AND DIGITAL INSTRUMENTS Digital Voltmeter (DVM) Used to measure the ac and dc voltages and displays the result in digital form. Types: Ramp type DVM Integrating type DVM Potentiometric type DVM

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS DC POWER SUPPLIES We will discuss these instruments one at a time, starting with the DC power supply. The simplest DC power supplies are batteries which

More information

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab University of Jordan School of Engineering Electrical Engineering Department EE 204 Electrical Engineering Lab EXPERIMENT 1 MEASUREMENT DEVICES Prepared by: Prof. Mohammed Hawa EXPERIMENT 1 MEASUREMENT

More information

Analog Digital Multimeter with Insulation Resistance Measurement

Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities

More information

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope. 3.5 Laboratory Procedure / Summary Sheet Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope. Set the function generator to produce a 5 V pp 1kHz sinusoidal output.

More information

XK-700 DELUXE DIGITAL / ANALOG TRAINER

XK-700 DELUXE DIGITAL / ANALOG TRAINER XK-700 DELUXE DIGITAL / ANALOG TRAINER DELUXE COMPLETE MINI-LAB FOR BUILDING, TESTING AND PROTOTYPING ANALOG AND DIGITAL CIRCUITS Elenco s advanced designed Digital/Analog Trainer is specially designed

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

FUNCTION GENERATOR KIT

FUNCTION GENERATOR KIT FUNCTION GENERATOR KIT MODEL FG-500K Assembly and Instruction Manual Elenco Electronics, Inc. Copyright 2005 by Elenco Electronics, Inc. All rights reserved. Revised 2005 REV-B 753069 No part of this book

More information

Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018

Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018 Simple measurement at the best price Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018 Contents Clamp-on multimeters page 3 Multimeters

More information

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal

More information

Electronic Circuits EE359A Final project requirements

Electronic Circuits EE359A Final project requirements Design an electronic circuit it may be one of the ideas described below or a similar project of your choosing. Senior Design projects are acceptable designs if the design is yours, and not your team s.

More information

Instrument Usage in Circuits Lab

Instrument Usage in Circuits Lab Instrument Usage in Circuits Lab This document contains descriptions of the various components and instruments that will be used in Circuit Analysis laboratory. Descriptions currently exist for the following

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

Interpreting Specifications

Interpreting Specifications www. transmille.com 4015 EXTENDED SPECIFICATIONS Interpreting Specifications TRANSMILLE LTD Interpreting Specifications Transmille have taken great care over presenting the extended specifications in a

More information

770E DIGITAL MULTIMETER OPERATOR S MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL 770E DIGITAL MULTIMETER OPERATOR S MANUAL TABLE OF CONTENTS 1.Overview... 1 2.Panel Layout...1/2 3. Safety information... 2 4. Specical cautions for operation.... 2 5.General specifications...2/3 6.Testing

More information

DL-91 DL-92 DL-94 DL-97

DL-91 DL-92 DL-94 DL-97 DL-91 DL-92 DL-94 DL-97 (Accuracy 0.5%) (Accuracy 0.3%) (Accuracy 0.1%) (Accuracy 0.06%) OUTLINE These four digital multimeters of the DL-90 Series have been designed to meet the diversifying needs users

More information

Indeks: WMXXCMM60 Advanced Industrial Multimeter

Indeks: WMXXCMM60 Advanced Industrial Multimeter CMM-60 Indeks: WMXXCMM60 Advanced Industrial Multimeter Description The CMM-60 multimeter allows you to record data thanks to the Trend Capture function of the built-in memory as well as the possibility

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

CHAPTER 6. Motor Driver

CHAPTER 6. Motor Driver CHAPTER 6 Motor Driver In this lab, we will construct the circuitry that your robot uses to drive its motors. However, before testing the motor circuit we will begin by making sure that you are able to

More information

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION Objectives: ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION The primary goal of this laboratory is to study the operation and limitations of several commonly used pieces of instrumentation:

More information

5080A Multi-Product Calibrator

5080A Multi-Product Calibrator 5080A Multi-Product Calibrator Calibration solutions for your analog and digital workload 5080A Multi-Product Calibrator: expanded workload coverage Calibrate analog and digital meters, and much more The

More information

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual Model 6610 1Hz to 10MHz Precision Phasemeter Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give long

More information

Handheld Digital Storage Oscilloscopes 2510 Series

Handheld Digital Storage Oscilloscopes 2510 Series Data Sheet Handheld Digital Storage Oscilloscopes The handheld digital storage oscilloscopes provide floating measurement and recorder capabilities with a built-in digital multimeter (DMM), all in one

More information

DEPARTMENT OF ELECTRICAL ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING LAB MANUAL SUBJECT: EMI B.TECH -3 RD SEM KCT COLLEGE OF ENGG & TECH FATEHGARH PUNJAB TECHNICAL UNIVERSITY Prepared by:- Er. Prince Munjal (AP) B.Tech (EE) M.Tech( EE)

More information

U1600 Series Handheld Digital Oscilloscopes

U1600 Series Handheld Digital Oscilloscopes U1600 Series Handheld Digital Oscilloscopes Data Sheet Delivering more functionality and performance with a handheld digital oscilloscope Features Three-in-one solution: Dual channel oscilloscope, True

More information

1587/1577 Insulation Multimeters

1587/1577 Insulation Multimeters 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information