SKIM USER S GUIDE SMART KAN INTERFACE MODULE 2 & 8 I/O

Size: px
Start display at page:

Download "SKIM USER S GUIDE SMART KAN INTERFACE MODULE 2 & 8 I/O"

Transcription

1 SKIM USER S GUIDE SMART KAN INTERFACE MODULE 2 & 8 I/O

2 Kongsberg Automotive: Christopher Martin Road Basildon, Essex England SS143ES Tel: +44(0) Fax: +44(0) , 28e Rue Grand-Mere (Qc) Canada G9T 7E9 Tel: (819) Fax:(819) C Kongsberg Automotive 2011 Specifications subject to change without notice. Any trademark used are recognised and are the property of thier respective owners. Part Number: P03882A00 December 2011

3 The SKIM User's Guide Thank you for choosing the SKIM 2 or 8 I/O gateway. These pages provide a brief introduction to CADET and provide operating instructions for the KGCT application used for managing configuration into SKIM gateway. Please read throught the guide before use. We hope you will be very happy with this product and have many years of trouble-free operation. If you have any problems or ideas for improvement then we would like to hear from you. For more information please see the web site:

4 Section/Contents Page 1. Installing CADET and KGCT Applications Understanding KGCT Functionality KGCT Application SKIM Frequency Output Limitation SKIM Limp Home Mode Typical J1939 Signal Ranges SKIM 2 I/O Electrical Connection SKIM 8 I/O Electrical Connection Electrical Specifications Typical J1939 wiring topology SKIM Typical I/O Applications Mechanical characteristics Maintenance and troubleshooting Glossary Important safety and legal information...33

5 1. Installing CADET and KGCT Applications If you whish to change the SKIM behaviour, the first step is to download CADET and KGCT applications. Both applications are available on the following web site: You need to get a user account and request for the profile KA Generic Product. Please note that the software requires at least Windows XP and one of the following USB to CAN interface: IXXAT interface Kvaser interface NEXIQ interface (USB-Link only) ifak system interface You will need to install the CAN interface drivers from the manufacturer website or the CD. Be aware that the drivers may not be compatible with your operating system. page 2

6 2. Understanding KGCT Functionality Because KGCT software is a plugin of CADET software, CADET must be started prior to access SKIM gateway. Then, you have to click on Read "button" or double-click on "CCP Node" in order to read the SKIM internal information datas: page 3

7 2.1 CADET "Module ID" tab Once the SKIM gateway is read, module information datas are displayed in read only mode. For this reason, no changes could be done here on datas. Note that customer parameters section could be modify to fit your needs. But to be able to do such operations, SKIM module must be place in bootloader mode (see below). 2.2 CADET "Commands" tab The following actions could be done (4 buttons available): Program a configuration (by loading a configuration file from disk and saving it into the SKIM memory). Get the internal configuration and start automatically KGCT application. Launch KGCT application (without getting internal SKIM configuration). Start bootloader mode. SKIM must be read again. In bootloader mode, customer parameters and firmware could be updated. 2.3 CADET firmware update When in bootloader mode, SKIM application firmware can be updated by clicking the Firmware button and following the information on screen. Note that firmware update could only be done from CADET. page 4

8 3. KGCT Application Basically, KGCT is used to create, edit, save (on disk) or write (in SKIM) different configurations for general I/O pins. Each I/O pin could be configured individually as an input or an output to do one of the following functions: PWM Output Mode Ohm Meter Mode Frequency Meter Mode Volt Meter Mode Ampere Meter Mode Pulse counter Mode Square Wave Output Mode Switch Input Mode Low Side Output Mode The next sections will describe how to configure the I/O pins for each of the functions listed above. page 5

9 3.1 PWM Output Mode In this mode, the I/O is configured as PWM output generator like the following: Used to set the frequency output. Frequency range is from Hz to 25 khz. Used to enable or disablethe internal 6.8 kω pullup resistor. Used to set the PWM output polarity: Ex.: PWM = 25% with active pulse HIGH Ex.: PWM = 25% with active pulse LOW Used to set the initial output duty cyle. Also used as limp home value when no J1939 messages detected. Also used as limp home value when no J1939 messages detected. Duty cycle range is from 0% to 100% When "Enable" is checked, output duty cycle value is read directly from the CAN bus. Used to select PGN number, data index (from which byte data will be retrieved) and data size (expressed in byte). page 6

10 3.1 PWM Output Mode - continued Used to scale the incoming data. If fields are left empty, up to unsigned 32-bits input data is taken as is (%). Otherwise, linear interpolation is done according to the programmed fields to obtain duty cycle value from J1939 network. Once the configuration is completed: you can save it on disk with "Save" button you can write it into SKIM with "Write" button. * The way to save configurations is the same for all I/0 functions. page 7

11 3.2 Ohm Meter Mode In this mode, the I/O is configured as ohm meter input like the following: Resistor input range is from 0 to 400 Ω. This is a fixed range. Used to scale the outgoing data. If fields are left empty, up to unsigned 32-bits output data is taken as is (ohms). Otherwise, linear interpolation is done according to the programmed fields to obtain J1939 value (to be broadcasted) from resistor input value. Used to select the PGN number, priority and destination address. Used to select data index (from which byte data will be sent), data size (expressed in byte) and the desired message transmission rate. Note that 2 different messages could be send in this mode. page 8

12 3.3 Frequency Meter Mode In this mode, the I/O is configured as frequency meter input like the following: Used to select on which edge the SKIM will trig. Frequency input range is from 1 to 2500 Hz. Used to scale the outgoing data. If fields are left empty, up to unsigned 32-bits output data is taken as is (Hz). Otherwise, linear interpolation is done according to the programmed fields to obtain J1939 value (to be broadcasted) from frequency input value. Used to select the PGN number, priority and destination address. Used to Select data index (from which byte data will be sent), data size (expressed in byte) and the desired message transmission rate. Note that 2 different message could be send in this mode.!!! WARNING!!! If the input rate frequency reaches the maximum limit of 2500Hz for more then 10 consecutives cycles, the I/O is permanently disabled and reading will be set to zero after timeout time of 2s. Only power up reset restore I/O functionality. page 9

13 3.4 Volt Meter Mode In this mode, the I/O is configured as volt meter input like the following: Voltage input range could be: 0-12VDC or 0-32VDC. Used to scale the outgoing data. If fields are left empty, up to unsigned 32-bits output data is taken as is (V). Otherwise, linear interpolation is done according to the programmed fields to obtain J1939 value (to be broadcasted) from voltage input value. Used to select the PGN number, priority and destination address. Used to select data index (from which byte data will be sent), data size (expressed in byte) and the desired message transmission rate. Note that 2 different message could be send in this mode. page 10

14 3.5 Ampere Meter Mode In this mode, the I/O is configured as ampere meter input like the following: Used to scale the outgoing data. If fields are left empty, up to unsigned 32-bits output data is taken as is (A). Otherwise, linear interpolation is done according to the programmed fields to obtain J1939 value (to be broadcasted) from current input value. Current input range is from 0 to 25mA. This is a fixed range. Used to select the PGN number, priority and destination address. Used to select data index (from which byte data will be sent), data size (expressed in byte) and the desired message transmission rate. Note that 2 different message could be send in this mode.!!! WARNING!!! If the input current reaches the maximum limit of 25mA, the I/O is temporary disconnected to protect internal shunt resistor. When pin voltage falls under 5V, the I/O will be reconnected. page 11

15 3.6 Pulse Counter Mode In this mode, the I/O is configured as pulse counter input like the following: Used to select on which edge the SKIM will trig for pulse counting. Frequency input range is from 1 to 2500 Hz. The total pulse counter will be transmitted on J1939 network. Used to select the PGN number, priority and destination address. Used to select data index (from which byte data will be sent), data size (expressed in byte) and the desired message transmission rate. Note that 2 different message could be send in this mode.!!! WARNING!!! If the input rate frequency reaches the maximum limit of 2500Hz for more then 10 consecutives cycles, the I/O is permanently disabled and reading will freeze to last count value. Only power up reset restore I/O functionality. page 12

16 3.7 Square Wave Output Mode In this mode, the I/O is configured as square wave output generator like the following: Used to set the frequency output. Frequency range is from Hz to 25 khz. The duty cycle will set at 50%. Used to enable or not the internal 6.8 kω pull-up resistor. Used to set the signal level at SKIM startup. page 13

17 3.8 Switch Input Mode In this mode, the I/O is configured as switch input like the following: Used to determine the level to consider input as active. Used to select the PGN number, priority and destination address. Used to select data index (from which byte data will be sent), data bits (on which bits switch value state will be transmitted) and the desired message transmission rate. Note that 2 different message could be send in this mode. page 14

18 3.9 Low Side Output Mode In this mode, the I/O is configured as low side output like the following: Used to enable or disable the internal 6.8 kω pullup resistor. Used to determine the output state (ON/OFF) when J1939 "Enable" is not checked. Also used as limp home value when no J1939 messages detected. When activated, output always gives a GND signal level. Used to determine the activation logic when J1939 "Enable" is checked. When DIRECT logic is seleted, output will be activated when incoming data is "1". When INVERSE logic is seleted, output will be activated when incoming data is "0". When activated, output always gives a GND signal level. page 15

19 3.9 Low Side Output Mode - continued Used to select the PGN number for incoming data. Used to select data index (within which byte data will be received) and data mask bits (from which bits activation data will be read). page 16

20 4. SKIM Frequency Output Limitation Because of the SKIM hardware, there are some limitations when using "frequency functions". Those limitations are only related to the SKIM 8 I/O. The same frequency should be used for I/O 1 and 3 (all connected to the same TPM2 internal timer). The same frequency should be used for I/O 2, 4, 5, 6, 7 and 8 (all connected to the same TPM1 internal timer). For a specific timer, if the frequencies defined for its related I/0 are not the same, then the frequency defined for the first I/O connected on the timer will be used. Example: I/O 2, 5 and 6 are configured as frequency functions using 3 different frequencies. The SKIM will use the frequency defined for I/O 2 for all other inputs / outputs. And in this case, resuting values for I/O 5 and 6 will be incoherent. page 17

21 5. SKIM Limp Home Mode The PWM Output Mode is related to an incoming J1939 message. If the SKIM loses the CAN network or the associated output message before timeout event, the output value will be set to the limp home value. In this particular case, the "Initial Duty Cycle" field is used as limp home value. The Low Side Output Mode is related to an incoming J1939 message. If the SKIM loses the CAN network or the associated output message before timeout event, the output value will be set to the limp home value. In this particular case, the "Initial Output State" field is used as limp home value. Each I/O output have his own limp home mode. The timeout period is set to time of 20s. page 18

22 6. Typical J1939 Signal Ranges This section defines the range of values that will be used in scaling functions for incoming and outgoing parameters on J1939 CAN network. 6.1 Transmitted / Received Signal Range name 1 byte 2 bytes 4 bytes Valid signal 0x00 to 0xFA 0x0000 to 0xFAFF 0x to 0xFAFFFFFF Error indicator 0xFE 0xFExx 0xFExxxxxx Not available / Not requested 0xFF 0xFFxx 0xFFxxxxxx 6.2 Transmitted Discrete Values Range Name Transmitted Bits Disabled (off) 00 Enabled (on) 01 Error indicator 10 Not available / Not installed Received Discrete Control Commands Range Name Received Bits Disable command (turn off) 00 Enable command (turn on) 01 Reserved 10 Don t care / No action 11 page 19

23 7. SKIM 2 I/O Electrical Connection The SKIM 2 I/O interfaces to data via the 6 pin Delphi connector on the module wired as shown (see pinout diagram). The SKIM can be wired to the vehicle electric system using the one of the following Mating Delphi Metri-Pack Series Connectors: # pin # pin # pin Pinout diagram for SKIM 2 I/O: Connector pin out Signal Notes A1 I/O #1 Configurable I/O #1 B1 I/O #2 Configurable I/O #2 C1 CAN HI CAN HI data line (J1939) D1 CAN LO CAN LO data line (J1939) E1 Power (-) Module power return F1 Power (+) Module power (9-32VDC) Supply should be protected by 500mA-rated circuit breaker / fuse page 20

24 8. SKIM 8 I/O Electrical Connection The SKIM 8 I/O interfaces to data via the 6-pin Delphi connector (1x) and the 3-pin Delphi connectors (2x) on the module wired as shown (see pinout diagram). The SKIM can be wired (connector #1) to the vehicle electric system using the one of the following Mating Delphi Metri-Pack Series Connectors: # pin # pin # pin Pinout diagram for SKIM 8 I/O (connector #1): Connector pin out Signal Notes A1 I/O #1 Configurable I/O #1 B1 I/O #2 Configurable I/O #2 C1 CAN HI CAN HI data line (J1939) D1 CAN LO CAN LO data line (J1939) E1 Power (-) Module power return F1 Power (+) Module power (9-32VDC) Supply should be protected by 500mA-rated circuit breaker / fuse page 21

25 8. SKIM 8 I/O Electrical Connection - Continued The SKIM can be wired (connectors #2 and #3) to the vehicle electric system using the one of the following Mating Delphi GT Series mm Centerline Connectors: # pin (connector #2) # pin (connector. # 3) Pinout diagram for SKIM 8 I/O (connectors #2 and #3): Connectors pin out Signal Notes A2 I/O #3 Configurable I/O #3 B2 I/O #4 Configurable I/O #4 C2 I/O #5 Configurable I/O #5 A3 I/O #6 Configurable I/O #6 B3 I/O #7 Configurable I/O #7 C3 I/O #8 Configurable I/O #8 page 22

26 9. Electrical Specifications INPUTS Digital Pulse counter Frequency Input Mode Digital Input Mode Voltage Input Mode Resistance Mode Current Input Mode Signal Level Frequency Range Resolution Accuracy 4 to 32 V 1 to 2500 Hz 50 ns ± 0.01 % Signal Level Resolution Accuracy 4 to 32 V Range Resolution Accuracy 0 to 12 V 0 to 32 V 12 mv 32 mv ± 1 % ± 2 % Range Resolution Accuracy Precision 0 to 400 Ω --- ± 2 % ± 1 Ω Range Resolution Accuracy Precision 0 to 25 ma --- ± 1% ± 50 ua page 23

27 OUTPUTS COMMUNICATION

28 10. Typical J1939 wiring topology Most modern engine installations include a harness with built in J1939 backbone. (Check engine manufacturer's documentation). If not, it is critical to use twisted shielded pair with a drain wire (max length 40m) terminated with 120 ohm resistors at each end. In addition, all stubs shoud not exceed 1m in length. Termination Resistor (120 ohm) Backbone (Max length 40m) SKIM module I/O#1 I/O#2 J1939 external device Stub (Max length 1m) SKIM module I/O#1 I/O#8 Termination Resistor (120 ohm) page 25

29 11. SKIM Typical I/O Applications VBATT VBATT SKIM 750R 6K8 I/0 Shunt 200R Protection Low side Switch 30 K SKIM Schematic I/O Bloc Diagram page 26

30 11.1 Analog Input Applications VBATT SKIM SKIM 750R I/ Ohms I/ VDC 0-32 VDC I/0 Ohm meter input mode Volt meter input mode SKIM I/0 Shunt 200R 0-25 ma Ampere meter input mode page 27

31 11.2 Digital Output Applications VBATT SKIM VBATT SKIM Load: ma 0-25 khz I/0 Pull Option 6K8 Low side Switch Load >= 10K 0-25 khz I/0 Low side Switch Low side output mode Low side ouput mode (with pull option) page 28

32 11.3 Digital Input Applications VBATT SKIM VBATT VBATT SKIM Pull Option Pull Option 6K8 External Pull Option 6K8 I/0 I/ Hz 4-32 VDC Frequency Meter Input Mode Pulse Counter Input Mode Switch Input Mode (Low Side) VBATT SKIM I/0 30K Switch Input Mode (High Side) page 29

33 12. Mechanical characteristics TBD page 30

34 13. Maintenance and troubleshooting No regular maintenance is required. If you are experiencing operating problems with SKIM, check these diagnostics: Problem Unit does not power up Unit does not communicate Unit does not give output Possible solution Ensure connections to unit are correct. Ensure power source is present. Ensure power source is present. Ensure connections to unit are correct. Ensure connections to J1939 network. Ensure connections to unit are correct. page 31

35 14. Glossary BYTE CAN J1939 PWM Means 8 bits. Controller Area Network (also referred to as CANbus); serial communication protocol for automotive use. SAE engine data protocol using CAN 2.0B. Pulse Width Modulation. page 32

36 15. Important safety and legal information Under no circumstances shall Kongsberg Automotive or any of its subsidiary companies accept liability for any loss of data, income, incidental damage or consequential losses incurred as a result of the use of the product howsoever caused when used as a monitor for electronically-controlled engines / transmissions or other systems. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without written permission of Kongsberg Automotive is prohibited. Kongsberg Automotive operates a policy of continuous improvement. Kongsberg Automotive reserves the right to alter and improve SKIM module and the KGCT software without prior notice. page 33

37 Kongsberg Automotive: Christopher Martin Road Basildon, Essex England SS143ES Tel: +44(0) Fax: +44(0) , 28e Rue Grand-Mere (Qc) Canada G9T 7E9 Tel: (819) Fax:(819) C Kongsberg Automotive 2011 Specifications subject to change without notice. Any trademark used are recognised and are the property of thier respective owners. Part Number: P03882A00 December 2011

38 Kongsberg Automotive: Christopher Martin Road Basildon, Essex England SS143ES Tel: +44(0) Fax: +44(0) , 28e Rue Grand-Mere (Qc) Canada G9T 7E9 Tel: (819) Fax:(819) C Kongsberg Automotive 2011 Specifications subject to change without notice. Any trademark used are recognised and are the property of thier respective owners. Part Number: P03882A00 December 2011

with Electronic Assistant

with Electronic Assistant TECHNICAL DATASHEET #TDAX021300 Valve Controller 6 On/Off P/N: AX021300 2 Analog and 3 Frequency Command Inputs 6 On/Off Outputs (Option: PWM) CAN (SAE J1939) with Electronic Assistant Features: 2 user

More information

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939) TECHNICAL DATASHEET #TDAX022000 Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference (SAE J1939) Features: 1 universal signal input 2 proportional or on/off outputs up to 3 A User

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12 PDM module (4 selectable polarity outputs) with 4 Inputs (selectable polarity) and 4 MFI Inputs P/N 610-00035 PAGE

More information

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment Features: 6 Universal Signal Inputs are user configurable as: o 0-5V, 0-10V, 4-20mA or 0-20mA o 20Ω to 250 kω Resistive o 1 Hz to 10 khz PWM o Digital o Three of the inputs can be configured as a pulse

More information

Applications: Power generation, Cogeneration, Stationary power Large engines

Applications: Power generation, Cogeneration, Stationary power Large engines Features: 8 inputs are user selectable from the following. 0-5V, 0-10V, 4-20 ma or 0-20 ma Digital inputs for interface to switches, etc. PWM signal, pulse or 16-bit counter inputs from sensors or diesel

More information

Programmable K-Factor Scaler B and Programming Software Kit B

Programmable K-Factor Scaler B and Programming Software Kit B Programmable K-Factor Scaler B220-885 and Programming Software Kit B220-900 INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770

More information

BMS BMU Vehicle Communications Protocol

BMS BMU Vehicle Communications Protocol BMS Communications Protocol 2013 Tritium Pty Ltd Brisbane, Australia http://www.tritium.com.au 1 of 11 TABLE OF CONTENTS 1 Introduction...3 2 Overview...3 3 allocations...4 4 Data Format...4 5 CAN packet

More information

Programmable with Electronic Assistant Simulink

Programmable with Electronic Assistant Simulink TECHNICAL DATASHEET #TDAX022410 2 Universal Inputs, Dual Valve Controller 2 Universal Signal Inputs 2-3A Outputs Drive Hydraulic Valves CAN (SAE J1939) Programmable with Electronic Assistant Simulink P/N:

More information

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board IXDP610 Digital PWM Controller IC Evaluation Board General Description The IXDP610 Digital Pulse Width Modulator (DPWM) is a programmable CMOS LSI device, which accepts digital pulse width data from a

More information

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER TECHNICAL DATASHEET #TDAX020510 6 INPUTS, 5 OUTPUTS VALVE CONTROLLER Up to 6 Digital, Analog or PWM Command Inputs 5 Independent Proportional or On/Off Outputs 1 +5V, 100 ma Reference Voltage CAN (SAE

More information

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER Preliminary TECHNICAL DATASHEET TDAX130540 ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER 2 Analog (Bipolar), Resistive, Digital, Frequency (RPM) or PWM Signal Inputs Encoder Input Magnetic Pick Up Input

More information

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions F5140 and Programming Kit F5141 8635 Washington Avenue Racine, WI 53406 USA Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com www.flo-tech.com TABLE

More information

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR 40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Ordering Part Numbers: SAE J1939 version Controller: AX022400

Ordering Part Numbers: SAE J1939 version Controller: AX022400 TECHNICAL DATASHEET #TDAX022400 2 Universal Inputs, Dual Valve Controller 2 Universal Inputs 2-3A Outputs CAN (SAE J1939) Programmable with Electronic Assistant P/N: AX022400 Features: 2 universal signal

More information

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER, TECHNICAL DATASHEET #TDAX020400 12 INPUT, 12 OUTPUT VALVE CONTROLLER, Multi-functional 7 Signal and 5 Digital Inputs 8-2.5A Proportional and 4-3A On/Off Outputs 1 +5V, 100 ma Reference Voltage CAN (SAE

More information

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939) Features: TECHNICAL DATASHEET #TDAX021610 Universal Input, Single Output Valve Controller CAN (SAE J1939) 1 universal signal input (voltage, current, resistive, PWM, frequency or digital) 1 output: proportional

More information

with Electronic Assistant

with Electronic Assistant Description: The quad valve controller provides precise, repeatable control of 4 proportional solenoids and 1 on/off solenoid over a SAE J1939 network. PWM signal inputs or analog voltage or current inputs

More information

Controlling DC Brush Motor using MD10B or MD30B. Version 1.2. Aug Cytron Technologies Sdn. Bhd.

Controlling DC Brush Motor using MD10B or MD30B. Version 1.2. Aug Cytron Technologies Sdn. Bhd. PR10 Controlling DC Brush Motor using MD10B or MD30B Version 1.2 Aug 2008 Cytron Technologies Sdn. Bhd. Information contained in this publication regarding device applications and the like is intended

More information

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650 Preliminary TECHNICAL DATASHEET #TDAX100650 DC MOTOR CONTROLLER P/N: AX100650 Variable Speed Control, Onboard Inputs 6A DC Motor Output, 2.5A Proportional Output, 2 Signal Outputs CAN SAE J1939, Rugged

More information

TECHNICAL DATASHEET #TDAX021901

TECHNICAL DATASHEET #TDAX021901 TECHNICAL DATASHEET #TDAX021901 8 In, 5 Output Valve Controller 6 Universal Analog Inputs, 1 Digital Input 1 Magnetic Pickup Sensor Input 4-2.5A Proportional or On/Off Outputs 1-2.5A Digital Output CANopen

More information

Operation/Reference Guide NXP-CPI16. NetLinx Custom Panel Interface. Custom Panel Interfaces

Operation/Reference Guide NXP-CPI16. NetLinx Custom Panel Interface. Custom Panel Interfaces Operation/Reference Guide NXP-CPI16 NetLinx Custom Panel terface Custom Panel terfaces Last Revised: 5/18/2012 AMX Limited Warranty and Disclaimer AMX warrants its products to be free of defects in material

More information

TLE5014 Programmer. About this document. Application Note

TLE5014 Programmer. About this document. Application Note Application Note About this document Scope and purpose This document describes the Evaluation Kit for the TLE5014 GMR based angle sensor. The purpose of this manual is to describe the software installation

More information

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...

More information

Accurate Lambda Meter. ALM Communication Protocol. -CAN bus V2.0 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Accurate Lambda Meter. ALM Communication Protocol. -CAN bus V2.0 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED. Accurate Lambda Meter ALM Communication Protocol -CAN bus V2.0 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED Http://www.ecotrons.com Note: If you are not sure about any specific details, please contact

More information

Accurate Lambda Meter. ALM Communication Protocol. -CAN bus V1.9 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Accurate Lambda Meter. ALM Communication Protocol. -CAN bus V1.9 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED. Accurate Lambda Meter ALM Communication Protocol -CAN bus V1.9 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED Http://www.ecotrons.com Note: If you are not sure about any specific details, please contact

More information

K-FACTOR SCALER B & B

K-FACTOR SCALER B & B K-FACTOR SCALER B220-880 & B220-881 INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638 Phone: 262.639.6770 Fax:

More information

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw isma-b-w0202 isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw www.gc5.com 1. Introduction... 4 2. Safety rules... 4 3. Technical specifications... 5 4. Dimension... 6 5. LED Indication...

More information

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers: Features: Command messages are received through the CAN network (no physical inputs) 10 universal outputs of up to 2.5A are user selectable from the following types (up to a maximum of 7A of controller

More information

LCC-10 Product manual

LCC-10 Product manual LCC-10 Product manual Rev 1.0 Jan 2011 LCC-10 Product manual Copyright and trademarks Copyright 2010 INGENIA-CAT, S.L. / SMAC Corporation Scope This document applies to i116 motion controller in its hardware

More information

P/N: AX Applications: Typical applications can include: test stands; and industrial automation.

P/N: AX Applications: Typical applications can include: test stands; and industrial automation. Description: The universal motor controller, 100W, drives a brushed DC Motor up to 6A or a 3- phase BLDC motor up to 6A. It features two SAE J1939 ports. Interfacing with 12V or 24Vdc power, the controller

More information

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers: TECHNICAL DATASHEET #TDAX021201 CAN to 9 Output Valve Controller P/N: AX021201 CANopen Features: Command messages are received through the CAN network (no physical inputs) 9 outputs are user selectable

More information

maxon document number:

maxon document number: maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6

More information

P/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123

P/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123 TECHNICAL DATASHEET #TDAX181000 TC/Analog Inputs to CAN Controller 4 Thermocouple, 7 Analog & 3 Signal Inputs 12 Vdc, 24 Vdc, 48 Vdc 2 CAN (SAE J1939) with Electronic Assistant Description: The TC/Analog

More information

CPKS8. Photo of device

CPKS8. Photo of device CPKS8 Revised 16-nov-2011. Embedded software version 1. 1. Features The device is designed for using in control systems of accelerators. The device generates 8 output PWM signals. Similar devices (CAMAC

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

HB-25 Motor Controller (#29144)

HB-25 Motor Controller (#29144) Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267

More information

ECUMASTER PMU-16/PMU-16DL Preliminary Manual. ( , rev. 1.01) Page 1

ECUMASTER PMU-16/PMU-16DL Preliminary Manual. ( , rev. 1.01) Page 1 ECUMASTER PMU16/PMU16DL Preliminary Manual (1.7.217, rev. 1.1) Page 1 ATTENTION! The ECUMASTER PMU is designed for motorsport applications only and cannot be used on public roads! The installation of this

More information

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz DEVELOPMENT KIT (Info Click here) 2.4 GHz ZigBee Transceiver Module Small Size, Light Weight, +18 dbm Transmitter Power Sleep Current less than 3 µa FCC and ETSI Certified for Unlicensed Operation The

More information

Graphical Control Panel User Manual

Graphical Control Panel User Manual Graphical Control Panel User Manual DS-MPE-DAQ0804 PCIe Minicard Data Acquisition Module For Universal Driver Version 7.0.0 and later Revision A.0 March 2015 Revision Date Comment A.0 3/18/2015 Initial

More information

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121 TECHNICAL DATASHEET #TDAX030121 10 Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen Features: 10 user selectable signal inputs: o 0-5 V o 0-10 V o 0-20 ma o 4-20

More information

4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol. Software Version v2.03 SRM009FVAE0808

4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol.  Software Version v2.03 SRM009FVAE0808 SRM009FVAE0808 4590 Tank Side Monitor Mark/Space Communication Protocol Service Manual Software Version v2.03 www.varec.com Varec, Inc. 5834 Peachtree Corners East, Norcross (Atlanta), GA 30092 USA Tel:

More information

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

AcuMesh Wireless RS485 Network. User's Manual SOLUTION AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the

More information

ICM- CANBUS. CAN-Bus Guide. Inline Contamination Monitor EN

ICM- CANBUS. CAN-Bus Guide. Inline Contamination Monitor EN ICM- CANBUS Inline Contamination Monitor CAN-Bus Guide www.mpfiltri.co.uk 200.072-EN Document Revision 0.6 1 Introduction 1.1 Overview The ICM measures and quantifies the numbers of solid contaminants

More information

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site: P.N.: Book 092

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site:  P.N.: Book 092 SMR5000F Smart Radio Data Repeater User Manual ISRAEL Office: Email: info@kpsystems.com PO Box 42, Tefen Industrial Park, Tefen 24959 Tel: 972-4-987-3066 / Fax: 972-4-987-3692 USA Office: KP ELECTRONICS,

More information

Rev NGM EVO USER GUIDE

Rev NGM EVO USER GUIDE www.promax.it The information contained in this document are for informational purposes only and are subject to change without notice and should not be interpreted by any commitment by Promax srl. Promax

More information

IsoLoop Isolated QSOP CAN Transceiver Evaluation Board

IsoLoop Isolated QSOP CAN Transceiver Evaluation Board IsoLoop Isolated QSOP CAN Transceiver Evaluation Board Board No.: IL41050-1-01 About This Evaluation Board This Evaluation Board provides a complete isolated CAN node using the world s smallest isolated

More information

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz DEVELOPMENT KIT (Info Click here) 2.4 GHz ZigBee Transceiver Module Small Size, Light Weight, Low Cost Sleep Current less than 3 µa FCC and ETSI Certified for Unlicensed Operation The ZMN2405 2.4 GHz transceiver

More information

DVC700 Series Programmable System Controller

DVC700 Series Programmable System Controller Programmed with HCT s Intella Software Suite 23 I/O (14 inputs & 9 outputs), 2 CAN interfaces Supply voltage 9-30Vdc The is a robust programmable controller for solenoid-operated proportional valves. It

More information

TECHNICAL DATASHEET #TDAX022420

TECHNICAL DATASHEET #TDAX022420 TECHNICAL DATASHEET TDAX022420 Four Inputs, Two Outputs Universal Valve Controller 2 Universal Signal Inputs, Magnetic Pick Up Sensor, or Encoder Inputs 2-3A High Side, Low Side or Half-bridge Outputs

More information

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging TECHNICAL DATASHEET #TDAX102000 35A DC MOTOR CONTROLLER P/N: AX102000 Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging with Electronic Assistant Features: Unidirectional or bi-directional

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1 ULC Version 7.X August 2015 USER MANUAL pg. 1 Overview Universal LED Controller () provides independent true constant-current or voltage control of two LED loads from 0.02 to 4 Amps continuous (DC) with

More information

VersaMax Mixed Discrete / High-Speed Counter Module

VersaMax Mixed Discrete / High-Speed Counter Module Product Description The VersaMax Mixed Discrete High-Speed Counter (HSC) module,, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,

More information

I2C Demonstration Board I 2 C-bus Protocol

I2C Demonstration Board I 2 C-bus Protocol I2C 2005-1 Demonstration Board I 2 C-bus Protocol Oct, 2006 I 2 C Introduction I ² C-bus = Inter-Integrated Circuit bus Bus developed by Philips in the early 80s Simple bi-directional 2-wire bus: serial

More information

USB-PWM10. User s Manual

USB-PWM10. User s Manual USB-PWM10 User s Manual Windows, Windows2000, Windows NT and Windows XP are trademarks of Microsoft. We acknowledge that the trademarks or service names of all other organizations mentioned in this document

More information

OrionBMS Master/Slave Supplement

OrionBMS Master/Slave Supplement www.orionbms.com OrionBMS Master/Slave Supplement Document Version 1.1 Master / Slave (Series) Overview As of firmware version v2.4.0, multiple Orion BMS units can be configured to operate together in

More information

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1 Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11

More information

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1 ULC Version 6.2 June 12, 2013 USER MANUAL pg. 1 Overview Universal LED Controller () provides independent true constant-current or voltage control of two LED loads from 0.02 to 4 Amps continuous (DC) with

More information

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation B25A20FAC Series B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation FEATURES: All connections on front of amplifier Surface-mount technology Small size, low cost,

More information

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals. TECHNICAL DATASHEET #TDAX130521 ECONOMY DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER 2 Analog, Resistive, Digital, Frequency (RPM) or PWM Signal Inputs 2 Analog, Digital, Frequency or PWM Signal Outputs +5V

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

Brushed DC Motor Control. Module with CAN (MDL-BDC24) Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) Ordering Information Product No. MDL-BDC24 RDK-BDC24 Description Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) for Single-Unit

More information

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

PULSE INPUT MODULE PI232/PI272 USER S MANUAL UM-TS02 -E021 PROGRAMMABLE CONTROLLER PROSEC T2-series PULSE INPUT MODULE PI232/PI272 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage or human

More information

PACSystems* RX3i IC695MDL765

PACSystems* RX3i IC695MDL765 March 2011 PACSystems* RX3i IC695MDL765 Digital Output Module with Diagnostics 16-Channel The 24/125 volt DC 2A Smart Digital Output module, IC695MDL765, provides 16 discrete outputs in two isolated groups

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL 5Hz to 1MHz WIDE RANGE FULLY AUTOMATIC DISTORTION ANALYZER MODEL 6900B SERIAL NO. OPERATING AND MAINTENANCE MANUAL Unit 4, 15 Jonathan Drive, Brockton, MA 02301-5566 Tel: (508) 580-1660; Fax: (508) 583-8989

More information

PHOENIX CONTACT - 03/2007

PHOENIX CONTACT - 03/2007 Inline Function Terminal for Pulse Width Modulation and Frequency Modulation N AUTOMATIONWORX Data Sheet 6920_en_01 1 Description PHOENIX CONTACT - 03/2007 $ ' ) The terminal is designed for use within

More information

XL270 Series 270-Watt AC to DC Power Supplies Rev

XL270 Series 270-Watt AC to DC Power Supplies Rev PMBus Interface: User s Guide XL270 Series 270-Watt AC to DC Power Supplies 706679 Rev 09-26-18 User s Guide XL270 PMBus Interface This document and the PMBus firmware described within are subject to change

More information

MD04-24Volt 20Amp H Bridge Motor Drive

MD04-24Volt 20Amp H Bridge Motor Drive MD04-24Volt 20Amp H Bridge Motor Drive Overview The MD04 is a medium power motor driver, designed to supply power beyond that of any of the low power single chip H-Bridges that exist. Main features are

More information

Tarocco Closed Loop Motor Controller

Tarocco Closed Loop Motor Controller Contents Safety Information... 3 Overview... 4 Features... 4 SoC for Closed Loop Control... 4 Gate Driver... 5 MOSFETs in H Bridge Configuration... 5 Device Characteristics... 6 Installation... 7 Motor

More information

PCAN-MIO Universal Controller for CAN Applications. User Manual. Document version ( )

PCAN-MIO Universal Controller for CAN Applications. User Manual. Document version ( ) PCAN-MIO Universal Controller for CAN Applications User Manual Document version 1.12.1 (2018-01-11) Relevant products Product Name Model Part number Firmware version PCAN-MIO Industrial connector IPEH-002187

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com

More information

Mini-Expansion Unit (MEU) User Guide V1.2

Mini-Expansion Unit (MEU) User Guide V1.2 Mini-Expansion Unit (MEU) User Guide V1.2 Disclaimer Although every care is taken with the design of this product, JT Innovations Ltd. can in no way be held responsible for any consequential damage resulting

More information

AMU-214 Auxiliary Monitor Unit Operations Manual

AMU-214 Auxiliary Monitor Unit Operations Manual AMU-214 Auxiliary Monitor Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE AMU-214 SERIES ITS CABINET AUXILIARY MONITOR UNIT. REVISION: SEPTEMBER 2008 pn 888-0214-001 THE AMU-214 SERIES AUXILIARY

More information

etatronix PMA-3 Transmitter Tester Manual

etatronix PMA-3 Transmitter Tester Manual etatronix PMA-3 Transmitter Tester Manual TxTester_Manual_rev1.02.docx 1 Version Version Status Changes Date Responsible 1 Release Initial release 01. Apr. 2015 CW 1.01 Release Updated Figure 4 for better

More information

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0 CoolEx User Manual Revision 1.0 2 CoolEx User Manual Table of Contents Foreword 0 Part I Overview 3 Part II Configuration and Setup 4 1 Terminals Layout... 4 2 Modbus Address... Switch 4 Part III Functional

More information

DESCRIPTION DOCUMENT FOR WIFI / BT HEAVY DUTY RELAY BOARD HARDWARE REVISION 0.1

DESCRIPTION DOCUMENT FOR WIFI / BT HEAVY DUTY RELAY BOARD HARDWARE REVISION 0.1 DESCRIPTION DOCUMENT FOR WIFI / BT HEAVY DUTY RELAY BOARD HARDWARE REVISION 0.1 Department Name Signature Date Author Reviewer Approver Revision History Rev Description of Change A Initial Release Effective

More information

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) 217-3367 Ordering Information Product Number Description 217-3367 Stellaris Brushed DC Motor Control Module with CAN (217-3367)

More information

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide M-5578/0516 M-5578/0516 Section TABLE OF CONTENTS 1 Introduction... 1 2 Quick Guide on Getting Started... 2 Mounting the LVTX-10 Series

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

Sales & Marketing: Version 1.01

Sales & Marketing: Version 1.01 User s Manual II COPYRIGHT The entire contents of this instruction manual, including any future updates, revisions, and modifications, shall remain the properties of AMEC at all times. Unauthorized copies

More information

CAT bit Programmable LED Dimmer with I 2 C Interface DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION CIRCUIT

CAT bit Programmable LED Dimmer with I 2 C Interface DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION CIRCUIT 16-bit Programmable Dimmer with I 2 C Interface FEATURES 16 drivers with dimming control 256 brightness steps 16 open drain outputs drive 25 ma each 2 selectable programmable blink rates: frequency: 0.593Hz

More information

VersaMax Mixed Discrete / High-Speed Counter Module

VersaMax Mixed Discrete / High-Speed Counter Module Product Description The VersaMax Mixed Discrete High-Speed Counter module, IC200MDD841, has twenty 24VDC positive-logic type inputs and twelve positive-logic 24VDC 0.5Amp outputs. In its default configuration,

More information

Integrity Instruments

Integrity Instruments Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485M300 Series I/O Modules Digital

More information

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which

More information

MILFORD INSTRUMENTS Limited

MILFORD INSTRUMENTS Limited MILFORD INSTRUMENTS Limited DMX Receiver (#1-497) Rev1.5 09/01/2007 The DMX receiver module is designed to provide 8 consecutive channels of output from a standard DMX protocol input signal. The outputs

More information

UM DALI getting started guide. Document information

UM DALI getting started guide. Document information Rev. 2 6 March 2013 User manual Document information Info Content Keywords LPC111x, LPC1343, ARM, Cortex M0/M3, DALI, USB, lighting control, USB to DALI interface. Abstract This user manual explains how

More information

MV110-8AS. Analog input module 8 channel. User guide

MV110-8AS. Analog input module 8 channel. User guide MV110-8AS Analog input module 8 channel User guide MV110-8AS_2016.12_0226_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...

More information

Uni-Mux XQL Multi-Channel Data Acquisition Module

Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.

More information

SCI ISO-K CCD PCI CAN

SCI ISO-K CCD PCI CAN DCX Networks SCI (Serial Communication Interface): The system uses two wires; one to transmit and one to receive. ISO-K is the adaptation of the 9141 standards allowing two-way communication on a single

More information

DESCRIPTION NOTE MODEL 2200VM

DESCRIPTION NOTE MODEL 2200VM Instantly integrate any volume measurement meter such as water or gas meters into the LonWorks digital network. The firmware executes on a NeuroLogic Research Model 2200 and provides a low-cost interface

More information

Table of Contents. HWIO-Gateway User Manual

Table of Contents. HWIO-Gateway User Manual User Manual HWIO-Gateway INUX AB Katrinedalsg. 3, 504 51 Borås http://www.inux.se Copyright 2009 Uppdaterad 2010-01-12 Copyright 2009 INUX AB 1 Table of Contents 1. Product overview...3 2. License...3

More information

SMARTALPHA RF TRANSCEIVER

SMARTALPHA RF TRANSCEIVER SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design

More information

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions 601 System SourceMeter 60 Multi-Channel I-V Test Solutions SPECIFICATION CONDITIONS This document contains specifications and supplemental information for the Models 601 and 60. Specifications are the

More information

VT-DTMSA5-433M RF Transceiver Module User s guide

VT-DTMSA5-433M RF Transceiver Module User s guide RF Transceiver Module User s guide V-Chip Microsystems, Inc Add:6 floor, Longtang Building, Nan Shan Cloud Valley Innovation Industrial Park, No.1183, Liuxian Road, Nanshan District, Shenzhen city Tel:86-755-88844812

More information

X3M. Multi-Axis Absolute MEMS Inclinometer Page 1 of 13. Description. Software. Mechanical Drawing. Features

X3M. Multi-Axis Absolute MEMS Inclinometer Page 1 of 13. Description. Software. Mechanical Drawing. Features Page 1 of 13 Description The X3M is no longer available for purchase. The X3M is an absolute inclinometer utilizing MEMS (micro electro-mechanical systems) technology to sense tilt angles over a full 360

More information

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K Round Profile Housing with Analog POSICHRON position sensor in a stainless steel pressure tube Protection class IP68/IP69K Underwater applications, permanent pressure-proof up to 15 bar Measurement range

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative

More information

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING DESCRIPTION The versatile CAN I/O PLC with 14 inputs and outputs impresses with its compact design and its operating voltage range of 9 to 30 volts. It provides 8 I/Os that can be configured as inputs

More information