Circulation Revitaliser
|
|
- Eustace Lawson
- 5 years ago
- Views:
Transcription
1 IB-CB100EU _Layout 1 24/10/ :15 Page 1 Circulation Revitaliser Instruction Manual CB-100-EU 1
2 IB-CB100EU _Layout 1 24/10/ :15 Page 2 QUICK START GUIDE SAFETY INFORMATION - IMPORTANT - PLEASE READ: Should not be used by women in the first trimester of pregnancy,by people fitted with a pacemaker or other implanted medical device, or anyone being treated for existing deep vein thrombosis (DVT). THIS DEVICE DOES NOT VIBRATE! IT USES ELECTRICAL IMPULSES, NOT VIBRATION. For detailed operation of your Circulation Revitaliser please refer to the comprehensive instructions within this manual. To use Circulation Revitaliser immediately follow this 6 point quick start guide: 1. Remove Circulation Revitaliser and its accessories the packaging. 2. Insert batteries into the remote control (you don t have to use the remote control to use the device it s up to you). 3. Connect the DC adapter to a suitable mains outlet and plug the small DC socket into the device. 4. Turn on the power. 5. Remove your footwear and socks or stockings. PLACE YOUR BARE FEET ONTO THE FOOT PADS. YOUR RIGHT FOOT ON THE RIGHT FOOT PAD AND YOUR LEFT FOOT ON THE LEFT FOOT PAD. B0TH FEET NEED TO BE ON THE DEVICE FOR IT TO WORK. 6. Sit in comfortable chair. Place your bare feet on the left and right foot plates. Increase the intensity levels for the foot by pressing the SOLE^ or to press SOLE V to decrease the intensity. The intensity level ranges from 0-99, slowly increase the level until you begin to feel the micro-current stimulation. PLEASE NOTE, THE AIM IS NOT TO GET TO LEVEL 99 JUST FIND A SETTING THAT IS COMFORTABLE FOR YOU. FREQUENTLY ASKED QUESTIONS. Q: I cannot feel the device vibrate? A: THIS DEVICE DOES NOT VIBRATE. Q: I cannot feel anything in my feet? A: May be your SOLE setting is too low. Increase this until you can feel it (it goes all the way up to 99). Q: Yesterday I used it on SOLE setting 45, today I cannot feel anything? A: Your body s response to the therapy will alter from day to day. Some days you may have to increase the SOLE setting to feel the benefits. Q: My legs ache after using the device. A: Either you had it on a SOLE setting that was too high for you (so reduce this setting next time you use it) or you have used it too many times within a few days. Just give your legs time to relax and then re-use the device. Q: I really don t feel anything when using the device; even on a high SOLE setting A: You may be dehydrated, the device uses EMS which sends tiny electrical impulses to the sole of your feet. You need to drink plenty of fluids to feel the maximum benefits. 2
3 IB-CB100EU _Layout 1 24/10/ :15 Page 3 CB-100-EU 1 Instruction Manual Thank you for purchasing Circulation Revitaliser. We hope you will find it beneficial. Please note, before using the device, please read the user manual carefully and keep it safe in case you have to refer to it at a later date. Please let your family and friends know about the device as they may find it of benefit too. We also advise you to seek medical help or consult a doctor if your symptoms persist. PARTS IDENTIFICATION 1 Electrode Silicon Area for Foot Pads 3 Sole massage roller 5 LCD Screen 7 Electrode Pads 9 Electrode Wire 2 User manual 4 Adapter 6 Handle 8 Remote controller Circulation Reviataliser 3
4 IB-CB100EU _Layout 1 24/10/ :15 Page 4 WHAT IS ELECTRONIC NERVE STIMULATION INTENDED USE: Medical Purpose Increasing the flow of blood helping to reduce pain. PLEASE NOTE THAT IT MAY TAKE UP TO 4 WEEKS TO FEEL THE FULL BENEFITS OF THIS DEVICE. WE ADVISE USING THE DEVICE AT LEAST ONCE A DAY. IF YOU STOP USING THE DEVICE, YOU WILL STOP FEELING THE BENEFITS. REMEMBER TO DRINK PLENTY OF FLUIDS AND KEEP HYDRATED. IF YOU ARE HYDRATED THE EFFECTIVENESS OF THE DEVICE WILL DECREASE. THE ELECTRO PADS ARE THERE TO TARGET HARD TO REACH AREAS. YOU CAN USE THE ELECTRO PADS AT THE SAME TIME AS USING THE FOOT PADS. THE DEVICE HAS 25 PROGRAMMES. This Electronic Nerve Stimulator is intended to be used as a massager to relieve (muscle) pain, increase blood circulation, relax stiff muscles, reduce swollen feet and ankles and fatigue. The massaging effect is achieved by electronic stimulation of the nerves through electrode pads placed on the skin. Various massage regions and treatment programmes can be selected. Suitable Users: Please read safety information before using the unit. (This unit should not be used by people prohibited from doing so in safety information ). Environment: This unit is intended for home use only. Effectiveness: Massager: relieve of (muscle) pain, stiffness and fatigue. Precautions for use: Please read Notes on safety before using the unit. Electronic Nerve Stimulation is a non-invasive, safe nerve stimulation intended to reduce pain. The Circulation Revitaliser uses proven neuromuscular electrical stimulation therapy to send micro current pulses through the soles of your feet. This type of electrical stimulation is clinically proven to be safe and effective and can be carried out in the comfort of your own home. The Circulation Revitaliser improves muscles function by stimulating nerves increasing the flow of blood helping to reduce PAIN, SWELLING, TIRED AND ACHING LEGS 4
5 IB-CB100EU _Layout 1 24/10/ :15 Page 5 HOW TO USE 1. Place you BARE feet on the foot pads at the same time (your left foot on the left pad and your right foot on the right pad). 2. Press the switch button about 3 seconds to turn on the unit, then the LCD screen will light up in Blue MIN 3. Then you can adjust the mode by pressing MODE & MODE to select different modes, Maximum is the 25th mode SOLE MODE BODY 4. Please increase intensity by pushing the button of SOLE BODY Or decrease intensity by pushing the button of SOLE BODY 5. You can adjust the modes at anytime, but once mode is reset, the intensity will be returned to 0. From the new mode, the user should readjust the intensity 6. To terminate the massage period, user can turn off the unit anytime by expressing the Switch button about 3 seconds. PLEASE NOTE-THE AIM IS NOT TO GET TO 99 INTENSITY BUT FIND A COMFORTABLE SETTING FOR YOU. Tips: Please adjust the intensity gradually from lower to stronger. Most of our customers feel the intensity from 40 + onwards, the device goes up to 99. ON/OFF: Sole : Mode : Body : Sole : Mode : Body : press the button about 3 seconds to switch on or off the unit increase the output intensity of foot sole choose one mode from 25 pre-moded massage modes~upward increase the output intensity of electrode pads decrease the output intensity of foot sole choose one mode from 25 pre-moded massage modes~downward decrease the output intensity of electrode pads How to operate the remote control? 1. Open the battery cover behind of the remote control. 2. Put the two AAA batteries into battery cassette in correct polarities. 3. Close the battery cover. 5
6 IB-CB100EU _Layout 1 24/10/ :15 Page 6 SAFETY INFORMATION Notes: 1. Please note that only original HoMedics accessories and detachable parts are approved for use with this product. 2. Usually,this device is affected by high frequency electromagnetism and microwave radiation machine, please be far away from these machines beyond 500mm when using Persons with the following conditions must consult the doctor before using this unit: 1) acute disease 6) high fever 2) malignant tumour 7) abnormal blood pressure 3) infectious disease 8) skin sensory disorders or skin problems 4) pregnancy 9) receiving medical treatment, especially those feeling discomfort. May 5) cardiac dysfunction cause an accident or ill health. Do not use this unit near the heart, above the neck, on the head, around the mouth or on diseased skin. May cause an accident or ill health. - Application of electrodes near the thorax may increase the risk of cardiac fibrillation. Do not use this unit simultaneously with other therapeutic device or in combination with ointments including spray type ointments. May cause discomfort or ill health. Operation in close proximity (e.g. 1 m) to a shortwave or microwave therapy EQUIPMENT may produce instability the STIMULATOR output. Do not use this unit for purposes other than treatment indicated in this manual. May lead to accident, problems, or failure of the unit. Do not insert the electrode cord plug into any place other than the electrode cord jack of the main unit. May cause an electric shock or accident. Do not disassemble or remodel this unit. No user serviceable parts. Caution If the unit is not functioning properly or you feel discomfort, immediately stop using the unit. If you feel any problems with your body or skin, consult a doctor and follow his/her instructions. If you want to move the Electrode Pad to another region or your body during treatment, be sure to turn off the power first. If not, you may receive a strong electrical shock. Do not try to attach the Pads to any other person during the treatment. You may receive strong electrical shock. Do not start treatment while wearing an electronic device. The settings and timings of the device may be affected. Do not use this unit on infants or people not capable of expressing their intentions. May cause an accident or ill health. Do not use this unit in places with high humidity such as bathrooms or while taking a bath or shower. You will receive a strong electrical shock. Do not use this unit while sleeping. The main unit may develop trouble, or the pad may move to an unexpected region and cause ill health. Do not use this unit while driving. Receiving sudden strong stimulation may lead to traffic accident. Do not leave the Electrode Pad attached to the skin after treatment. Prolonged attachment may cause skin irritation or infection. Be careful not to allow any metal object, such as a belt buckle or necklace to come into contact with the Electrode Pad during treatment. You may receive a strong electrical shock. Do not use cellular phones or other electronic devices near this unit. Put the Long Life pads only on skin or on the Long Life pads holder to avoid damage of the adhesive surfaces of the pads. 6
7 IB-CB100EU _Layout 1 24/10/ :15 Page 7 Explanation of figures, symbols, warning statements and abbreviations on the equipment Type BF applied part Attention consult accompanying documents 0120 CE Mark: conforms to essential requirements of the Medical Device Directive 93/42/EEC DISPOSAL do not dispose of electrical appliances as unsorted Batch code 2011 SN Company Address Serial number Date of manufacture Manufacturer Storage / Maintenance 1. Use wet cloth or neutral cleanser to wipe the machine, and don t use volatile liquid to clean the machine, such as benzene, thinner or gasoline 2. Keep it away from magnetic field and reach of children 3. Keep the machine far away from moisture, high temperature, direct sunlight or sprinkling water 4. If the electrode pads are insufficiently adhesive or dirty, please wipe with a wet cloth or change new ones. Don t clean the electrode pads with any chemical 5. Please do not dismantle, repair or rebuild the machine yourself, or you will invalidate your warranty 6. If not use it for a long time, please remove the batteries from remote controller WEEE explanation This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Specifications Company: HoMedics Group Ltd Address: HoMedics House, Somerhill Business Park, Five Oak Green Road, Tonbridge, Kent TN11 0GP, UK Model number: Circulation Revitaliser This equipment belongs to Type BF of Class II according to Clause 5. Rated: 5 V dc, 1000 ma Powered by adaptor: WT Rated Voltage: V Rated frequency: 50-60Hz Rated input: 0.1 A Rated output: 5v 1000mA Output waveform: Square wave Pulse duration: 115 μs Pulse repetition frequencies: HZ Effect of load impedance: 1KΩ Maximum amplitude of output voltage: 72V Operation condition: 0 40 ºC % RH 860 hpa to hpa Store and transport condition: 0 40 ºC % RH 860 hpa to hpa 7
8 IB-CB100EU _Layout 1 24/10/ :15 Page 8 Caution for Electrode Gel Pads Never stick two adhesive pads to each other. Keep the adhesive gel pads clean, and never put them under high temperature and direct sunshine. If the electrode gel pads are insufficiently adhesive or dirty, wipe with a wet cloth or change new ones. Don't clean the electrode gel pads with any chemical To protect the gel pads, always put them onto the gel pad protector after use. Trouble Shooting-Electro Pads Question Reason Solution No stimulation Weak stimulation The skin becomes red and painful The power cut off during therapy Are the wires connected? Is the protective membrane cover removed from the pads? Are the pads stuck tightly to the skin? Are the pads overlapped? Are the pads dirty? Are the pads damaged? Therapy time is too long? The pads too dry? The pads are sticked too tightly? The pads are dirty? The pads are damaged? The pads fall off from the skin? The wire connect cut off? No battery? The therapy time over? Connect wire correctly Remove the protective membrane of the pads Stick the pads tightly Detach the pads, and stick again Clean the pads Adjust the intensity to be stronger Change the stick place Therapy time always be minutes once Clean with wet cloth, then use again Stick the pads lightly to the skin Clean the pads Change the pads Turn off the power, stick the pads again Turn off the power, connect the pads again Change battery The power will turn off after 15 minutes therapy Description of modes Mode Pattern Mode Pattern 1 Reflex points Pushing 14 Scrapping Pressing 2 Reflex points 3 4 Reflex points Kneading Reflex points Tapping 5 Scrapping 6 Squeezing 7 Massage Pushing Massage Pushing Squeezing Reflex points Squeezing Reflex points Hammering 12 Kneading 15 Cupping 16 Body Shaping 17 Hammering 18 Massage Tapping 19 Pushing 20 Rolling Pounding 21 Squeezing 22 Stroke 23 Reflex points Squeezing 24 Shiatsu 25 Rolling Kneading 13 Thumping 8
9 IB-CB100EU _Layout 1 24/10/ :15 Page 9 ELECTRODE PADS THERAPY USAGE ExAMPLE TARGET AREA: Shoulder, Back Symptom: Shoulder, back muscle ache, etc TARGET AREA: Back, Hips, Waist Symptom: Discomfort, aches and pain TARGET AREA: Arms Symptom: Sore arms, aching muscles TARGET AREA: Shoulder, Back Symptom: Shoulder, back muscle ache, etc 9
10 IB-CB100EU _Layout 1 24/10/ :15 Page 10 TROUBLESHOOTING & MAINTENANCE Problem Cause Rectification Device will not turn on. The adapter does not plug well into device properly. Power turns off too soon Power turns off while using massager It is difficult to attach Gel pad to the skin Adhesive surface of Gel pad is not sticky It is difficult to feel stimulation The skin turns red or the skin feels irritated Gel pads not attached correctly to the skin. Treatment period of 25 minutes is over and power turns off automatically If you are using the body massage, the electrode gel pad may be broken Transparent film not peeled off Gel pad applied immediately after washing Adhesive surface of Gel pad damaged The gel pads got dirty and lost their adhesive/stickiness Use of Gel pad whilst perspiring Gel pad washed too long and/or too frequently Gel pads stored under high temperature, high humidity, direct sunlight You sole is too dry, not enough moisture Your sole is not placing on the foot pedal properly Gel pads not attached correctly to the skin Gel pads overlap each other Electrode cord not connected correctly Applied intensity too weak Adhesive surface of Gel pads dirty or dry Adhesive surface of Gel pads damaged Check the mains power is switched on. The adaptor is in correctly. Attach Gel pads correctly to the skin Restart treatment or turn off the massager Replace electrode gel pad Peel off film on the adhesive surface of Gel pad Sufficiently dry Gel pad Replace Gel pad Replace Gel pad or clean the gel pad with a small drop of water onto the sticky side of the electrode pad and rub into the surface Leave Gel pad in freezer for overnight Put some water on your sole to moisturise your sole Ensure both of your soles are placed on each pedal properly. Attach Gel pad firmly to the skin Reattach Long Life pads with no overlap Connect electrode cord correctly Increase the intensity by pressing the + button. Wash adhesive surface of Gel pads softly with your fingertips for about 3 seconds under slow running water Replace Gel pads 10
11 IB-CB100EU _Layout 1 24/10/ :15 Page 11 ACCOMPANYING DOCUMENTS Instructions for use 1. CIRCULATION REVITALISER needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS; 2. Portable and mobile RF communications equipment can affect CIRCULATION REVITALISER. 3. Warning that the use of accessories, transducers and cables other than those specified with the exception of transducers and cables sold by the manufacturer of the CIRCULATION REVITALISER as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the CIRCULATION REVITALISER. 4. Warning that the CIRCULATION REVITALISER should not be used adjacent to or stacked with other equipment 5. Guidance and manufacturer s declaration electromagnetic emissions The CIRCULATION REVITALISER is intended for use in the electromagnetic environment specified below. The customer or the user of the The CIRCULATION REVITALISER should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment guidance RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC Voltage fluctuations/ flicker emissions IEC Group 1 Class B Class A Complies The CIRCULATION REVITALISER uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The CIRCULATION REVITALISER is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. After using the product Clean the device with a soft, damp cloth but make sure squeeze a cloth dry and to clean the foot pedal area. Store the Electrode Gel pads on the plastic pad protectors provided. 11
12 IB-CB100EU _Layout 1 24/10/ :15 Page Guidance and manufacturer s declaration Electromagnetic Immunity The CIRCULATION REVITALISER is intended for use in the electromagnetic environment specified below. The customer or the user of the CIRCULATION REVITALISER should assure that it is used in such an environment. Immunity test IEC test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC ±6 kv contact ±8 kv air ±6 kv contact ±8 kv air Floors should be wood, concrete or ceramic tile. If the floor is covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/burst IEC ±2 kv for power supply lines ±2 kv for power supply lines Mains power quality should be that of a typical commercial or hospital environment. Surge IEC ±1 kv line(s) and neutral ±1 kv line(s) and neutral Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC ± 2 kv line(s) to earth <5% U T (>95% dip in U T ) for 0.5 cycle 40% U T (60% dip in U T ) for 5 cycles ± 2 kv line(s) to earth <5% U T (>95% dip in U T ) for 0.5 cycle 40% U T ) (60% dip in U T ) for 5 cycles Mains power quality should be that of a typical commercial or hospital environment. If a dips or an interruption of mains power occurs, the current of the CIRCULATION REVITALISER may be dropped off from normal level, it may be necessary to use uninterruptible power supply or a battery. 70% U T (30% dip in U T ) for 25 cycles 70% U T (30% dip in U T ) for 25 cycles Power frequency (50/60 Hz) magnetic field IEC <5% U T (>95% dip in U T ) for 5 sec <5% U T (>95% dip in U T ) for 5 sec 3A/m 3A/m If image distortion occurs, it may be necessary to position the Circulation Revitaliser image intensifier further from sources of power frequency magnetic fields or to install magnetic shielding. The power frequency magnetic field should be measured in the intended installation location to assure that it is sufficiently low. NOTE: U T is the a.c. mains voltage prior to application of the test level. 12
13 IB-CB100EU _Layout 1 24/10/ :15 Page Guidance and manufacture s declaration electromagnetic immunity The CIRCULATION REVITALISER is intended for use in the electromagnetic environment specified below. The customer or the user of the CIRCULATION REVITALISER should assure that it is used in such an environment. Immunity test Conducted RF IEC Radiated RF IEC IEC test level 3 V/ms 150 khz to 80 MHz 3 V/m 26 MHz to 2.5 GHz Compliance level Electromagnetic environment - guidance 3 V/ms 3 V/m Portable and mobile RF communications equipment should be used no closer to any part of the CIRCULATION REVITALISER, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance d = 1,2 P d = 1,2 P 80 MHz to 800 MHz d = 2,3 P 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. a To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the CIRCULATION REVITALISER is used exceeds the applicable RF compliance level above, the CIRCULATION REVITALISER should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the CIRCULATION REVITALISER. b Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m. 13
14 IB-CB100EU _Layout 1 24/10/ :15 Page Recommended separation distances between portable and mobile RF communications equipment and the Circulation Revitaliser The CIRCULATION REVITALISER is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the CIRCULATION REVITALISER can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the CIRCULATION REVITALISER as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 khz to 80 MHz d = 1,2 P 80 MHz to 800 MHz d = 1,2 P 800 MHz to 2,5 GHz d = 2,3 P 0, , For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 14
15 IB-CB100EU _Layout 1 24/10/ :15 Page 15
16 IB-CB100EU _Layout 1 24/10/ :15 Page HoMedics Group Ltd, HoMedics House Somerhill Business Park, Five Oak Green Road Tonbridge, Kent TN11 0GP, UK Register your product today at: IB-CB-100EU
Powered Traction Unit OPERATION MANUAL
Powered Traction Unit OPERATION MANUAL CONTENTS Symbols Safety precautions Symbol for CAUTION Symbol for CONSULT INSTRUCTIONS FOR USE Symbol for SERIAL NUMBER Symbol for CATALOGUE NUMBER Symbol for AUTHORISED
More informationEnglish
English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm
More informationBIODEX MULTI- JOINT SYSTEM
BIODEX MULTI- JOINT SYSTEM CONFORMANCE TO STANDARDS 850-000, 840-000, 852-000 FN: 18-139 5/18 Contact information Manufactured by: Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704
More informationGuidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System
Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet
More informationHeRO duet
HeRO duet CUSTOMER SERVICE TABLE OF CONTENTS TABLE OF CONTENTS OVERVIEW OVERVIEW OVERVIEW OVERVIEW USING HeRO duet USING HeRO duet USING HeRO duet Current HeRO Score HeRO USING HeRO duet USING HeRO duet
More informationGeneral Safety/EMC and Electrical Information for i-limb ultra and i-limb digits
1. General Safety 1.1 The i-limb ultra and i-limb digits devices are electrical devices, which under certain circumstances could present an electrical shock hazard to the user. Please read the accompanying
More informationD C 01/2019 3
D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while
More informationINTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.
Table of contents INTRODUCTION.............................. 4 SAFETY INSTRUCTIONS........................ 5 ABOUT THIS DEVICE.......................... 6 FIRST OPERATION............................ 7
More informationWireless TENS Pain Reliever. WT1 Series
Wireless TENS Pain Reliever WT1 Series Content Introduction Parts Features General Warnings and Safety Using your Wireless TENS Pain Reliever Troubleshooting Positions for use Mode Selection Specification
More informationElectromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)
Compressor set Equipment Under Test (EUT) Type 028 Type 047 Type 052 Type 085 Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN 60601-1-2:2007 (IEC 60601-1-2:2007) 2017 PARI
More informationTH008F Multi-function Infrared Forehead Thermometer
TH008F Multi-function Infrared Forehead Thermometer Specifications Functions Temperature measurement range: Forehead mode: 34~42.2 C (93.2~108 F), Surface mode: -22~80 C (-7.6~176 F) Operating temperature
More informationBiological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.
Biological Safety Observe the following precautions related to biological safety. WARNING: Non-medical (commercial) grade peripheral monitors have not been verified or validated by SonoSite as being suitable
More informationBy Paul Aylett at 12:08 pm, Apr 13, 2016
TD2 Series Content Introduction Parts Features General Warnings and Safety Using your TENS Pain Reliever Troubleshooting Positions for use Specification Compatibility EMC Maintenance and Cautions Explanation
More informationRolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large
Rolyan Splint Pan OPERATION MANUAL Item #081544816 - Small Item #081544808 Large PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW SPLINT PAN. Failure to follow these instructions could result in
More informationUSER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17
USER MANUAL MHS-2500I Please take time to read these instructions before starting to use the scale Version 1.0 05/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of
More informationTechnical Specifications Micromedical VisualEyes 505 by Interacoustics
VisualEyes 505 - Technical Specifications Page 0 Technical Specifications Micromedical VisualEyes 505 by Interacoustics D-0115523-B 2018/02 VisualEyes 505 - Technical Specifications Page 1 Included and
More informationPHYSIOFLOW Q-LINK TM
PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...
More informationNursing Beds with Dewert drive system
Nursing Beds with Dewert drive system GB Casa Med Classic 4 / Classic (FS) Casa Med Ultra / Ultra (FS) Casa Med Classic Low Casa Med Classic (FS) 4 / Classic / Casa FS Med / Casa Classic Med Low Ultra
More informationUser Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8
User Instruction Computer Assisted Local Analgesia 1-800-667-9622 337 Marion, Le Gardeur QC, Canada, J5Z 4W8 USER INSTRUCTION Congratulations on your new CALAJECT! Please read these instructions thoroughly
More informationTranscutaneous Electrical Nerve Stimulator
Transcutaneous Electrical Nerve Stimulator Simple, effective pain relief *For the temporary relief of pain as part of current medication programme. Distributor Medi-Direct International Ltd. Unit 24, Wilford
More informationVN415/VO425 Specifications
VN415/VO425 Specifications Item No. 8105231-1 01/2014 Contents VN415 Specifications... 1 1.1 Technical Standards:...1 1.2 System Requirements:...1 1.3 Included and Optional Parts...2 VO425 Specifications...
More information(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual
Edition 1 Notice i-pad Operator s Manual CU Medical Systems, Inc. reserves the right to make changes on the device specifications contained in this manual at any time without prior notice or obligation
More information: 0089 GTIN
GTIN: 00894912002050 PRECAUTIONS PROBE Non-invasive probes are for transcutaneous use only Probe transducer tips are thin and delicate. Be careful not to drop or hit the probe tip. After use, protect the
More informationNot for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT
Cochlear Implants Microphone Test Device with SONNET MTD Adapter User Manual AW32690_1.0 (English) Table of contents 1. Table of contents 2. INTRODUCTION 3 Product description 3 3. INTENDED USE INDICATIONS
More informationWRIST BLOOD PRESSURE MONITOR
WRIST BLOOD PRESSURE MONITOR Instruction Manual MODEL: ABP801 www.accumed.com TABLE OF CONTENTS INTRODUCTION... 1 NOTES ON SAFETY... 1 ABOUT BLOOD PRESSURE... 3 PRECAUTIONS BEFORE US... 4 FEATURES OF THE
More informationUSER MANUAL M-200. Please take time to read these instructions before starting to use the scale. Version /06
USER MANUAL M-200 Please take time to read these instructions before starting to use the scale Version 1.0 07/06 Contents Introduction 3 Product Specification 3 Safety Instructions 4 Explanation of Graphic
More informationOperating Manual Infrared thermometer
Operating Manual Infrared thermometer Model:IT-121 Professional Fast Accurate 1 CONTENTS 1 I n t r o d u c t i o n................ 3 1.1Product intended use 3 2 Basic principle 3 3 Pr o d u c t f e a t
More informationPain Management System
TM Pain Management System Model: ireliev Model #: ET-1313 Operating & Instruction Manual Read Before Using ireliev Pain Management System Intended Use The ireliev Pain Management System (Model # ET-1313)
More informationMedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11
INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13
More informationSAVI SCOUT Surgical Guidance System. Console Operation Manual
SAVI SCOUT Surgical Guidance System Console Operation Manual 2 Copyrights and Trademarks 2016 Cianna Medical, Inc. All rights reserved. Patents pending. Cianna Medical and SAVI are registered trademarks
More informationUser Manual. Before Using Your WiTouch Pro Device
User Manual Before Using Your WiTouch Pro Device Sync the Remote Control and the WiTouch Pro Device. Using the provided screwdriver, remove the back cover from the WiTouch Pro device. 2. Remove the clear
More informationM-400 M-410 M-420 M-430
USER MANUAL M-400 M-410 M-420 M-430 Please take time to read these instructions before starting to use the scale Version 1.1 10/17 Contents Introduction 3 Product Specification 3 Safety Instructions 4
More informationOtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06
OtoRead - Technical Specifications Page 0 Technical Specifications OtoRead D-0116698-A 2017/06 OtoRead - Technical Specifications Page 1 OtoRead TM Configuration Overview The OtoReadTM is available in
More informationTechnical Data. Electrocardiograph ECG-1250K TD.ECG1250_L. This technical data may be revised or replaced by Nihon Kohden at any time without notice.
Technical Data Electrocardiograph ECG-1250K This technical data may be revised or replaced by Nihon Kohden at any time without notice. TD.ECG1250_L Specifications ECG input Input impedance: 20 MΩ Electrode
More informationINSTRUCTIONS FOR YOUR NEW PLASMAFLOW. Vascular Therapy System (Compressible Limb Sleeve Device)
INSTRUCTIONS FOR YOUR NEW PLASMAFLOW Vascular Therapy System (Compressible Limb Sleeve Device) Customer Service Toll Free: 888-508-0712 Email: CustomerService@manamed.net Web: www.manamed.net 1511 W. Alton
More informationThe following symbol indicates that the device is MR-unsafe:
The following symbol indicates that the device is MR-unsafe: MR Unsafe Do not use this equipment In the MRI scan room Patient must follow the doctor s instructions and should not perform a self-assessment
More informationDENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK
M 505 DENTAL X-RAY OPERATOR'S INSTRUCTIONS (for USA) Wall Mount Type...WK WARNING This X-ray equipment may be dangerous to patient and operator unless safe exposure factors, operating instructions and
More informationBodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use
BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 1 Body Clock Stimplus TM Instructions for use BodyclockStimplusManual.qx8_Layout 1 17/08/2012 11:53 Page 2 Acupuncture is an ancient Chinese therapy
More information#
INSTALLATION MANUAL 2 Contents Getting To Know Your AVANT POLAR HIT TM... 4 Setting up the System... 6 Software Installation... 7 Driver Installation Windows 7... 10 Driver Installation Windows XP... 13
More informationCentral Blood Pressure Meter Model cbp301. Operating Manual
Central Blood Pressure Meter Model cbp301 Operating Manual Document cbp301-009 Issue 4 September 2011 Contents Introduction... 3 Package Contents... 5 Warnings and Cautions... 6 Contraindications... 7
More informationUser Manual. Glass Body Fat Analyzer LS203-B. version:1.0
version:1.0 User Manual Glass Body Fat Analyzer LS203-B Contains FCC ID: OU9AW8001-LS GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch
More informationThis manual is valid for the TM. In TENSity 5000 TENS Stimulator. This user manual is published by Current Solutions, LLC
INSTRUCTION MANUAL This manual is valid for the TM In TENSity 5000 TENS Stimulator This user manual is published by Current Solutions, LLC Current Solutions, LLC does not guarantee its contents and reserves
More informationBody Clock Stimplus Pro
Body Clock Stimplus Pro TM Instructions for use Acupuncture is an ancient Chinese therapy in which specific points on the body, known as acupuncture points (acupoints) are stimulated by the use of needles.
More informationRelief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak.
Relief. At Last. User Manual For an effective treatment, read the entire User Manual before using Kyrobak. Contents Know Your Kyrobak 2 Safety Instructions 3 Before You Start 4 How to Use Kyrobak 5 Operating
More informationGTIN:
GTIN: 00894912002920 TABLE OF CONTENTS Introduction...1 Features...1 Indications for Use...1 Contraindications...1 Warnings & Precautions...2 Controls...3 Operation...4 Recharging the Battery...5 Replacing
More informationCeiling Model Ceiling Model for LEDview Plus and Heliodent Plus. Installation Requirements. New as of: English
New as of: 03.2017 Ceiling Model Ceiling Model for LEDview Plus and Heliodent Plus Installation Requirements English Installation Requirements Ceiling Version = Dentsply Sirona Installation Requirements
More informationINTRODUCTION. It is also intended for symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis.
TENS / HEAT 1 2 TABLE OF CONTENTS Introduction...4 Indications for Use...4 Safety Warning...5 Contraindications...5 Warnings...5 Precautions...6 Adverse Reactions...8 Symbol and Title...8 Environmental
More informationisoothe User Manual WIRELESS RECHARGEABLE TENS INV-942R
isoothe WIRELESS RECHARGEABLE TENS Rechargeable Battery 20 Minute Treatment Timer 5 Preset Modes 15 Intensity Levels Auto Shut-Off Clinically Proven User Manual INV-942R This manual is applicable to the
More informationINSTALLATION MANUAL AVANT HIT+ Hearing Instrument Test Chamber.
INSTALLATION MANUAL AVANT Hearing Instrument Test Chamber HIT+ www.medrx-int.com Contents Getting To Know Your AVANT HIT+. 3 Computer Requirements 4 Setup System. 5 Software Installation.. 6 Sound Card
More informationOperator s Manual External Remote Controller (ERC)
OM0000-C, 2010-07 Page 1 of 25 Table of Contents 1. SYMBOLS DEFINITION:...3 2. PRODUCT WARNINGS:...6 3. PRODUCT DESCRIPTION:...8 4. COMPONENT IDENTIFICATION:...8 5. INSTRUCTIONS FOR USE:...9 6. EMERGENCY
More informationCompressor Nebulizer. Model No: 9R-021 series. Please read the instruction manual before use.
Compressor Nebulizer Model No: 9R-021 series Please read the instruction manual before use. IMPORTANT SAFEGUARDS...... 1 1. INTRODUCTION... 6 2. PRODUCT DESCRIPTION... 7 3. OPERATION... 8 4. CLEANING...
More informationWelch Allyn Home Scale (T- RPM-SCALE100)
Welch Allyn Home Scale (T- RPM-SCALE100) Directions for use 901077 Weight scale, Software Version 1.0 2017 Welch Allyn. All rights are reserved. To support the intended use of the product described in
More informationThe following languages can be found on our website: French. German. Spanish. Italian. Swedish. Portuguese. Russian. Dutch.
Manufactured By: 5580 S. Nogales Hwy. Tucson, Az 85706 USA Telephone: 800-975-7987 Fax: 520-294-6061 www.westmedinc.com PN 74586, Rev. 10 MT Promedt Consulting GmbH Altenhofstr. 80 66386 St. Ingbert, Germany
More informationMini TENS. User Manual. Natural, drug-free pain relief. 20 Minute Treatment Single Patient Use. Model ACRL Clinically Proven
Mini TENS Natural, drug-free pain relief 20 Minute Treatment Single Patient Use Clinically Proven User Manual Model ACRL-1000 This manual is valid for the AccuRelief Mini TENS ACRL-1000 This instruction
More informationAS SUPER 4 digital. Elektrischer Nadelstimulator / Electrical needle stimulator. Art.-Nr
AS SUPER 4 digital Elektrischer Nadelstimulator Electrical needle stimulator Art.-Nr. 200510 Gebrauchsanweisung Instruction Manual - Art.-Nr. 101477 20 Contents Foreword...21 Purpose for use...21 Safety
More informationENG en. Operating instructions. Iris Magneton MF Wellness therapy
ENG en Operating instructions Iris Magneton MF Wellness therapy Edition 09 / 2012 These operating instructions constitute an accessory of the device. They must therefore be kept in a suitable place near
More informationAUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL
AUTOMATIC BLOOD PRESSURE MONITOR (Arm Cuff Type) INSTRUCTION MANUAL Model: SPBP-04 English Instruction Guide Thank you for choosing Advocate as your monitor of choice. The first, most important part of
More informationL NKTEMP. Non-contact. Infrared Thermometer. User Manual LMP001
L NKTEMP Non-contact Infrared Thermometer User Manual LMP001 TABLE OF CONTENTS Product Description Intended Use Product Features Safety Precautions Using the Thermometer Taking a Measurement Temperature
More informationPOCKET AIR. Portable Nebulizer. Instruction Manual MBPN002 / MB / MB05006
R POCKET AIR Portable Nebulizer Instruction Manual MBPN002 / MB0500300/ MB05006 Table of Contents General information... 1 Intended Use... 2 Safety Precautions... 3 Explanation of Symbols... 4 Package
More informationMulti-Control Panel for built-in system. Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001
Multi-Control Panel for built-in system Multi Pad for NLX / imd OPERATION MANUAL OM-E0538E 001 Thank you for purchasing Multi Pad. Read this Operation Manual carefully before use for operation instructions
More informationENGLISH. Important safety information Read this important information carefully before you use the device and save it for future reference.
SCH740 EN www.philips.com/avent Philips Consumer Lifestyle BV Tussendiepen 4, 9206 AD Drachten, Netherlands Trademarks owned by the Philips Group. 2017 Koninklijke Philips N.V. All rights reserved Find
More informationSJM MRI Activator. Handheld Device. User's Manual. Model EX4000
SJM MRI Activator Handheld Device User's Manual Model EX4000 Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL
More informationProduct Name: COMPER SMART DOPPLER FETAL MONITOR. Product Model: DFMX
DFMX User Manual Document Num: History of Change: User Manual JS02114DFMX V1.0 Issue Date: Version: Editor: Reviewer: Approver: Date:xx-xx-xx Date:xx-xx-xx Date:xx-xx-xx Product Name: COMPER SMART DOPPLER
More informationOperation Guide Model: 405-HT V3.0
MODEL 405-HT Operation Guide Model: 405-HT V3.0 Fully Automatic Wrist Cuff Blood Pressure Monitor (ELECTRONIC SPHYGMOMANOMETER) OPERATION GUIDE INDEX IMPORTANT INFORMATION... 2 CONTENTS AND DISPLAY INDICATORS...
More informationOsmolarity System USER MANUAL FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES. osdcare.com
Osmolarity System FOR QUANTITATIVE MEASUREMENT OF OSMOLARITY OF OCULAR TISSUES USER MANUAL osdcare.com I-PEN User Guide I-PEN User Guide TABLE OF CONTENTS I-PEN I-PEN is a trademark of I-MED Pharma Inc.
More information2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands
SCH740 2015 Koninklijke Philips N.V. All rights reserved Philips Consumer Lifestyle BV Tussendiepen 4, 9206AD Drachten, Netherlands 4213.354.3816.3 (11/2015) >75% recycled paper >75% papier recyclé 2 3
More informationDIGITAL BLUETOOTH THEROMETER PBT
DIGITAL BLUETOOTH THEROMETER PBT Index 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Introduction Important Information Before Use Product Identification Description of LCD Display Battery Installation
More informationUSER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus
USER S MANUAL Volk Pictor Plus Fluorescein Angiography (FA) Module For Use with: Volk Pictor Plus IM-080 Rev. A Page 1 of 16 THIS SALES PACKAGE INCLUDES: Model: Fluorescein Angiography (VP2FA) IM-080 Description:
More information#0086.
INSTALLATION MANUAL Contents Getting to Know Your AVANT REM Speech+... 3 Software Installation... 4 Driver Installation Windows 7... 7 EMC Precautions... 11 Safety... 15 Limited Warranty... 18 #0086 www.medrx-usa.com
More informationBLOOD PRESSURE MONITOR
E BLOOD PRESSURE MONITOR Instructions and Guarantee BPW-9100 NORMAL BLOOD PRESSURE FLUCTUATION All physical activity, excitement, stress, eating, drinking, smoking, body posture and many other activities
More informationH2 Check Operating Manual
H2 Check Operating Manual Federal (USA) law restricts this device to sale by or on the order of a physician or licensed practitioner. Micro Direct, Inc. 803 Webster Street Lewiston, ME 04240 1-800-588-3381
More informationIEC Second Edition
Electromagnetic Compatibility of Medical Electrical Equipment Second Edition Prepared by Mr. James Conrad Presented by Dr. William A. Radasky 1 Second Edition Updates first edition on standards developed
More informationSeries 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual
Series 1 Remote Multiple Mode Remote Controlled Electro Stimulation Control Unit User Manual Issue 5.0 March 2010 WELCOME 4 2 Key Features 4 WHAT'S IN THE KIT? 5 Contents 5 Quick Guide 5 Before Use 5 USING
More informationPhilips body analysis scale with Bluetooth Smart DL8781, DL8780 EN-US
Philips body analysis scale with Bluetooth Smart DL8781, DL8780 EN-US 1 3 4 5 1 2 6 7 8 9 10 11 12 English 6 6 English Contents Introduction 7 General 7 Explanation of symbols 8 General description (Fig.
More informationTABLE OF CONTENTS CONVENTIONS AND GRAPHICAL SYMBOLS 1. INTRODUCTION 2 2. WARNINGS 3 3. CAUTIONS 4 4. ADDITIONAL BENEFITS 5 5. PACKAGE CONTENTS 6
USER S MANUAL TABLE OF CONTENTS 1. INTRODUCTION 2 2. WARNINGS 3 3. CAUTIONS 4 4. ADDITIONAL BENEFITS 5 5. PACKAGE CONTENTS 6 6. USING LIVIA 6 7. CHARGING LIVIA 11 8. SPECIFICATIONS 11 9. SYSTEM CONTROLS
More informationOPERATOR S MANUAL AN APPLIED DIGITAL COMPANY
OPERATOR S MANUAL AN APPLIED DIGITAL COMPANY Contents: VeriChip H2 Reader Assembly Part Number 600-000515-000 (includes all of the following): USER INSTRUCTIONS Description Part Number Description The
More informationDraft. User s Manual. Transmitter Model EX1150
User s Manual Merlin @home Transmitter Model EX1150 CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 2008 St. Jude Medical Cardiac Rhythm Management Division.
More information`bob`=p=^åèìáëáíáçå=råáí
`bob`=p=^åèìáëáíáçå=råáí qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the mouth.
More informationJPD-FR302. User Manual. Infrared Thermometer
JPD-FR302 User Manual Infrared Thermometer User Instructions For proper use of the product, please read this manual before using the product, and follow this manual when operating the product. Before using
More informationSE: Bruksanvisning GB: User Guide ES: Instrucciones DE: Gebrauchsanweisung IT: Istruzioni per l uso FR: Consignes d utilisation.
SE: Bruksanvisning GB: User Guide ES: Instrucciones DE: Gebrauchsanweisung IT: Istruzioni per l uso FR: Consignes d utilisation active Svenska... 3 English... 9 Español... 15 Deutsch... 21 Italiano...
More informationOPERATOR'S INSTRUCTIONS DENTAL X-RAY MODEL 096
DENTAL X-RAY MODEL 096 OPERATOR'S INSTRUCTIONS 0197 WARNING: This X-ray equipment may be dangerous to patients and operators unless safe exposure factors and operating instructions are observed. R Table
More informationCardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring. Technical Manual
CardioMessenger II-S Transmitter for BIOTRONIK Home Monitoring 362454_D_GA_CM_II-S_US.indd 1 Technical Manual 17.04.08 16:28:16 by BIOTRONIK GmbH & Co. KG All rights reserved. Specifications subject to
More informationManual of Electronic Pulse Stimulator
Manual of Electronic Pulse Stimulator PL-029K8B Operation Manual PL-029K8B Edition V1.0 1 Table of Contents Introduction...3 Indications for Use...3 Safety Warning... 4 Contraindications...4 Warnings...4
More informationTranscutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using
Transcutaneous Electrical Nerve Stimulator TENS 212 Instruction Manual Read before using TABLE OF CONTENTS GENERAL DESCRIPTION 1 SYSTEM COMPONENTS 1 WARRANTY 1 INDICATIONS AND CONTRAINDICATIONS 2 WARNINGS
More informationTransmitter Model EX1100, EX1100W. User's Manual
Merlin@home Transmitter Model EX1100, EX1100W User's Manual Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL
More information`bob`=p=^åèìáëáíáçå=råáí=bma
`bob`=p=^åèìáëáíáçå=råáí=bma qéåüåáå~ä=a~í~= båöäáëü The new CEREC 3 generation for the computer-aided manufacture of ceramic restorations. CAD system for making high-precision optical impressions in the
More informationHD STETH TM Quick Start User Guide
Thank you and for choosing the futuristic HD Steth TM manufactured by HD Medical Inc. USA Indications for Use (IFU) HD Steth is an electronic stethoscope meant to assist a qualified clinician to capture,
More informationConnevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at
Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk
More informationThis product may malfunction due to electromagnetic waves caused by portable
1 IMPORTANT NOTICE This product may malfunction due to electromagnetic waves caused by portable personal telephones, transceivers, radio-controlled toys, etc. Be sure to avoid having objects such as, which
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationNerve stimulator TWISTER
Nerve stimulator TWISTER INSTRUCTIONS FOR USE Softwareversion 1.19 Manufacturer: Dr. Langer Medical GmbH Fabrik Sonntag, Haus 4a 79183 Waldkirch Germany Table of contents 1 Intended use... 5 2 Common
More informationOperating Manual D-ACTOR 100
Operating Manual D-ACTOR 100 Published March, 2012 Original language: German STORZ MEDICAL AG Lohstampfestr. 8 CH-8274 Tägerwilen Switzerland 22629»elite edition +«11 381 02 0312 blank page 11 381 02 0312
More informationSplash-proof Wireless Stereo Speaker System User s Manual
Splash-proof Wireless Stereo Speaker System User s Manual Please read carefully before using this equipment and retain for future use. Introduction This splash-proof wireless speaker system uses the latest
More informationEICKEMEYER INFUSION WARMER
EICKEMEYER INFUSION WARMER MANUAL Art. No. 402091 TELEPHONE +49 7461 96580 0 www.eickemeyer.com Contents 1 Introduction... 3 2 Working Principle... 3 3 Main Technical Specifications... 3 4 Composition
More informationOPERATOR'S INSTRUCTIONS DX-073 DENTAL X-RAY
DENTAL X-RAY DX-073 Wall Mount Type...WK Ceiling Mount Type...CK Floor Mount Type...FK1/2 Mobil Mount Type...FM Room Mount Type...RKII OPERATOR'S INSTRUCTIONS 0197 WARNING : This X-ray equipment may be
More informationContent. User Instruction - Pointoselect digital. Intended use...3 Safe usage of the device...3 Description...4
2 Content Intended use...3 Safe usage of the device...3 Description...4 Operating the device Setting up the device...4 Starting the device...4 Mode selection...5 Measurement...5 Automatic...5 Manual...6
More informationAlways there to help you. Register your product and get support at AJ3400. Question? Contact Philips.
Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3400 User manual Contents 1 Important 3 2 Your clock radio 4 What's in the box 4 3
More informationDigital Wireless Weather System
Digital Wireless Weather System Thermometer, Hygrometer and Heat Index with Remote Sensor Leading the Way in Accuracy 1458 Instruction Manual C H CHANNEL Congratulations on your purchase of the Taylor
More informationSingle Channel TENS. Natural, drug-free pain relief. Target-specific pain relief. Clinically Proven. User Manual. Model ACRL-2000
Single Channel TENS Natural, drug-free pain relief Target-specific pain relief. Clinically Proven User Manual Model ACRL-2000 This manual is valid for the AccuRelief Single Channel TENS Pain Reliever ACRL-2000.
More informationDual Channel TENS. User Manual. Prescription Strength Pain Relief
User Manual Dual Channel TENS Prescription Strength Pain Relief Quick and Easy Set-Up 20 Minute Treatment Timer 12 Preset Modes 100 Intensity Levels Treatment Record Log Auto Shut-Off This manual is valid
More information