Delta Power Meter DPM Series
|
|
- Phillip Rose
- 5 years ago
- Views:
Transcription
1 utomation for a hanging World Delta Power Meter DPM Series
2 Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality parameters, including power factor, harmonics, and current / voltage unbalance with functions such as off - limit alarms and history logs. It provides exceptional communication quality and monitoring functions that are especially suitable for sectors where power quality is critical. DPM DPM Features High Precision Power Measurement Highly precise measurement of bidirectional electrical energy and power parameters, meeting lass 0.5S of IE62053 and S14607 standards Supports power quality measurement, including total and individual harmonic distortion, voltage and current unbalance, and more Supports 31 st harmonics distortion measurement Large Screen LD DPM White - light widescreen LD with resolution of 198x160 dots. Visibility better than segment - type LD Ptot kw Etot kvrh 1
3 Easy Operation and Installation Two mounting clips hold the meter in place, no other tools required Language customization: Traditional hinese, Simplified hinese and English uilt - in RS communication port supports MODUS communications protocol Transmission of all measurement values to the upper - level controllers via communication HMI SD Server Ethernet RS Event larms and History Logs DPM : Keeps max. 2 months of power and electricity energy measurement values for history analysis. Up to 17 power parameters selectable for recording different time intervals (ex. recording 17 electricity parameters every 5 minutes, for up to 2 months). 29 types of built-in event alarms for up to 500 event records DPM : 10 types of built-in event alarms. Front LED indicators for real - time alarms. larm messages with time stamps can be transmitted to upper - level controllers via communication 500 uto Meter Reading DPM Two built - in individual data registers record active / reactive energy in a certain given time lapse when triggered through communication. Two individual time lapse settings STRT STRT ED ED 2
4 Features Parameter Grouping Grouping the measurands for faster data transmission and reading by the upper - level controllers improves the efficiency and performance of data transmission. SD Server urrent Voltage Energy Demand RS DPM Power System P - based onfiguration Software Utilizing DPMSoft software through MODUS communication for power meter setup and data acquisition provides easy power management and analysis. IFD6500 RS DPM
5 HJGH VH FDH 22 SDF HJGHF GFY HJGH K VH FDH 02 SDF HJGUTYRK 457FY HJGH K VH FDH 18 SDF HDRWSJGK GJDFGDHFY HJGH K VH FDH 13 SDF HJGK GHG45FY HJGH K VH FDH 13 SDF HJGK GHG45FY pplications Medium / low voltage power distribution panels, Energy Management Systems, uilding Energy Management Systems, Factory Energy Management Systems Energy Management Systems Ethernet MODUS Human Machine Interface ctive Front End Power Meter Reactor Integrated Elevator Drive Programmable Logic ontroller Motor Drive Programmable Logic ontroller 7F 6F 5F Permanent Magnetic Synchronous Motor hiller ooling Tower Light 4F 3F 2F Motor Drive Motor Drive Light 1F ir Handling Unit Pump Lighting System Elevator HV System Factory Energy Management Systems Human Machine Interface Programmable Logic ontroller MODUS Temperature ontroller Pressure Sensor Timer / ounter / Tachometer Servo Drive Power Meter Motor Drive Hand Insertion Fluxing Wave Soldering Semi - finished Product Testing onformal oating Drying 4
6 Specifications Model DPM DPM Display Display Type White backlit LD LD urrent Instantaneour RMS Values Voltage Frequency Real, Reactive, and pparent Power Power Factor Energy Values ctive, Reactive, and pparent Energy uto Metering urrent - Demand Values Power - Functional haracteristics Power Quality Measurement alculation Mode lock - urrent / Voltage Unbalance Total Voltage Harmonic Distortion Total urrent Harmonic Distortion Individual urrent / Voltage Harmonic Distortion 2~31 - Max. / Min. of Instantaneous Values With Timestamp Data Recording Data Logs Type Selectable 17 measurement values - Data Logs Recording Duration Up to 2 months - larms History larms larms Types RS Port ommunicaton Parameters Grouping MODUS MODUS RTU / SII MODUS RTU urrent ±0.2% Voltage ±0.5% Measurement ccuracy Power ±0.5% ctive Energy IE S Reactive Energy ±0.5% Electrical haracteristics Power Factor ±0.5% Frequency ±0.5% Measurement Input haracteristics Wiring Method Measured Voltage Measured urrent Frequency Range Power Supply 1P2W, 1P3W, 3P3W, 3P4W L - L: 35~690 V L - : 20~400 V 1 / 5 45~70 Hz 80~265 V (Max. power consumption 4.6W) 100~300 VD ommunication RS Port aud rate 9600 / / 38400bps, MODUS 5
7 Mechanical haracteristics Environmental onditions Electromagnetic ompatibility IP Degree of Protection Model DPM DPM Front Display Meter ody Dimensions ( W x H x D ) Dimensions (mm) IP54 IP20 96 * 96 * 95.4 mm Operating Temperature - 20 ~ +70 Storage Temperature - 30 ~ +80 Humidity Rating ltitude ~95% RH elow 2000 m Electrostatic Discharge IE Immunity to Radiated Fields IE Immunity to Fast Transients IE Immunity to Impulse Waves IE onducted Immunity IE Immunity to Voltage Dips IE onducted and Radiated Emissions F part 15 E lass Harmonics Emissions IE Flicker Emissions IE Safety Europe E, IE61010 * Min / max of instantaneous : Phase voltage, line voltage, current, frequency, total 3 - phase active power, total 3 - phase reactive power, total 3 - phase apparent power, total power factor, total voltage harmonic distortion, total phase voltage harmonic distortion, total current harmonic distortion, phase voltage unbalance, 3 - phase voltage unbalance, 3 - phase current unbalance * larm types : Over - current, Under - current, Over natural current, Over line voltage, Under line voltage, Over phase voltage, Under phase voltage, Over voltage unbalance, Over current unbalance, Over active power, Over reactive power, Over apparent power, power factor (lead), power factor (lag), Over current demand, Over active power demand, Over reactive power demand, Over apparent power demand, Over frequency, Under frequency, Over total voltage harmonic distortion, Over total current harmonic distortion, Phase lose, Meter restore factory, Phase sequence reversal, Over DUI, Over EUI * Data log: Phase voltage, line voltage, current, natural current, power factor, displacement power factor, total active power, total reactive power, total apparent power, positive active energy, reversed active energy, positive reactive energy, reversed reactive energy, positive apparent energy, reversed apparent energy, total voltage harmonic distortion, total current harmonic distortion SPE.label
8 Wiring Diagram 1 - Phase 2 - Wire (1T) 3 - Phase 3 - Wire, Δ - connection (3T, no PT) 3 - Phase 4 - Wire, Y - connection (3T, no PT) 1 - Phase 3 - Wire (2T) 3 - Phase 3 - Wire, Δ - connection (2T, no PT) 3 - Phase 4 - Wire, Y - connection (2T, 3 PT) 3 - Phase 3 - Wire, Δ - connection (3T, 2PT) 3 - Phase 4 - Wire, Y - connection (3T, 3 PT) 7
9 DPMSoft User Guide PI Definition 4 D+ 5 D - US IFD PI 5 RJ - 45 Optional ccessories PI 4 Model Primary urrent Secondary urrent Max. Measurement ccuracy DT - S V 1.0% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% DT - S V 0.5% Sizes (mm) Outer Frame 115 x 89 x 51 Inner Frame 32 x 21 x 32 Outer Frame 115 x 89 x 51 Inner Frame 32 x 21 x 32 Outer Frame 115 x 89 x 51 Inner Frame 32 x 21 x 32 Outer Frame 115 x 89 x 51 Inner Frame 32 x 21 x 32 Outer Frame 145 x 116 x 51 Inner Frame 80 x 50 x 32 Outer Frame 145 x 116 x 51 Inner Frame 80 x 50 x 32 Outer Frame 145 x 116 x 51 Inner Frame 80 x 50 x 32 Outer Frame 145 x 116 x 51 Inner Frame 80 x 50 x 32 Outer Frame 196 x 146 x 51 Inner Frame 122 x 80 x 32 Outer Frame 250 x 186 x 1.4 Inner Frame x 81 x 32 Outer Frame 250 x 186 x 51.4 Inner Frame x 81 x 32 Outer Frame 250 x 186 x 51.4 Inner Frame x 81 x 32 8
10 Global Operations Taoyuan Technology enter (Green uilding) Taoyuan Plant 1 Taoyuan Plant (Diamond-rated Green uilding) arcelona Rome Milan H E F G D rasil Minas Gerais Espírito Santo Rio de Janeiro São Paulo State Paraná 9
11 ranch Offices 65 Distributors Dalian 34 Jin 10
12 DELT_I-DPM E_
Automation for a Changing World. Delta Power Meter DPM Series VARITEL
utomation for a hanging World Delta Power Meter DPM Series VRITEL VRITEL IGEIERI ELETROI S.. Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationPower Meter DPM-C530
utomation for a hanging World Power Meter DPM-530 www.deltaww.com Delta's Power Meter DPM-530 Series offers precise measurement of various electrical energy values and power quality parameters, including
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality
More informationDelta Power Meter DPM Series
utomation for a Changing World Delta Power Meter DPM Series www.deltaww.com Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power quality parameters, including
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Multifunction Power Meter DPM Series precisely measures various electrical energy and power quality
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Multifunction Power Meter DPM Series precisely measures various electrical energy and power quality
More informationDelta Power Meter DPM Series
utomation for a hanging World Delta Power Meter DPM Series www.deltaww.com Product Introduction Delta's Power Meter DPM Series offers precise measurement of various electrical energy values and power qual
More informationSmart Demand Controller
Smart Demand ontroller PowerLogic TM EM700 series Quick and easy installation Meter for all electrical panels Power energy monitoring PowerLogic TM EM700 - Smart Demand ontroller Functions and charteristics
More informationPower Meter Series PM3200 Functions and characteristics
Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring
More informationPM5000 Series. PowerLogic PM5100, PM5300 and PM5500 series
Functions and characteristics PowerLogic PM5100, PM5300 and PM5500 series PB111776 The PowerLogic applications. It provides the measurement capailities needed to allocate energy usage, perform tenant metering
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationElectrical network management. Schneider Electric. PM3200 Technical Datasheet
Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact
More informationSide view View from below Rear view
Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4
More informationAlpha 50. Technical Data Sheet. Special Features
Technical ata Sheet lpha 50 lpha 50 is a compact multifunction instrument with touch screen LC utility which measures important electrical parameters in 3 phase and single phase Network & replaces the
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationZHUHAI PILOT TECHNOLOGY CO., LTD.
SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationHV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point
2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION
More informationPQube 3 Specifications
PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,
More informationJewell DPM Power / Power Factor Size 96/96 BEST IN CLASS
Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has
More informationEASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter
SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationA Power Quality Interface for Low and Medium Voltage Smart Grids
Technical Data Power Quality Interface for Low and Medium Voltage Smart Grids Model PQI-D smart 1 Wall-mounted housing 1 DIN-Rail housing 1 Panel mounting housing 1. pplication Solving all measurement
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationE6500 Power Quality Analyzer
E6500 Power Quality Analyzer E6500 power quality analyzer can record and analyze all power quality parameters such as harmonics, voltage, current, frequency, fluctuation, flicker, power and three-phase
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More information150 C 30 F B D 8L 152H C 30 F BD 43 8L
ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open
More informationUMG 509-PRO. Multifunction power analyser with RCM
UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)
More informationC.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards
Keeping up with the standards C.A 8352 Power Quality Monitor Complete electrical network analysis at the tips of your fingers! All measurements for complete analysis: powers, harmonics, flicker, symmetry,
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationINSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13
INSTALLATION MANUAL Model: Smart Analyzer Manufacturer: Smart Impulse Power meter with consumption breakdown by use 03/12/13 Table of contents Table of contents... 2 1. Introduction... 3 2. Installation
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationUMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.
Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics
More informationPower supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation
Portable Description Features Measures all of the main electrical parameters of an electricity network Measurement in true root mean square Built-in energy meter With 4 voltage channels and 4 current channels
More informationChronos 2 electronic timers - Plug-in 8-pin (35 mm)
hronos electronic timers Plugin pin (5 mm) elay output or change over relays Multifunction or monofunction Multirange (7 ranges, available options) Multivoltage elay output or : 50 V (0 A L) Plugin LED
More informationConzerv EM6400NG series
Conzerv EM6400NG series Multi-function power & energy meters Technical datasheet PB115131 Introducing EM6400NG, next generation power meters of iconic EM6400 series with innovative Accurate measurements
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationNetwork Analyzer for Low-, Medium- and High-Voltage Networks
Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 150 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 FFT nalysis up
More informationChronos 2 electronic timers mm
hronos electronic timers.5 mm elay output DDP relay Multifunction or monofunction Multirange (7 ranges, available options) Multivoltage Output : 50 V ( L) Screw or spring terminals LED status indicators
More informationDelta Din-rail Power Meter DPM-D520I User Manual.
Delta Din-rail Power Meter DPM-D520I User Manual www.deltaww.com Table of Content 1. Preface 4 2. Notes 5 2.1 Safety Notes 5 2.2 Installation Environment 6 3. Descriptions of Parts 7 3.1 Operating Interface
More informationMulti-functional Power Meter DPM-C530A User Manual.
Multi-functional Power Meter DPM-C530A User Manual www.deltaww.com Table of Contents 1. Preface 2 2. Notes 3 2.1 Safety Notes 3 2.2 Installation Environment 4 3. Descriptions of Parts 5 3.1 Operating Interface
More informationCentrale de mesure Power Meter PM500 Merlin Gerin
Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with
More informationPMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.
PMAC770 Multifunction Power Meter Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals. The manufacturer shall not
More informationTechnical Data Sheet
Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application
More informationRS Pro ENGLISH. Datasheet
Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital
More informationRISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics
Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock
More informationATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW
Characteristics soft starter for asynchronous motor - ATS48-65 A - 208..690 V - 15..55 KW Main Range of product Altistart 48 Product or component type Product destination Product specific application Device
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationN100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.
cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy
More informationIntroduction DIN rail mounted electricity meters
Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More information1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus
speicher MID energy meter ECSEM series Emax 2 Tariffs GridVis 7 Tariffs 8 Tariffs 14 Tariffs 0,2 kwh Class 0,5 kwh Class 1,0 kwh Class Pulse output Tarife 2 tariffs Messgenauigkeit Modbus MID M-Bus eratureingang
More informationALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring
ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring The first Real-Time Protection and Automation platform that can be adapted to a wide variety of applications. While
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationPower quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I
Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationM ulti Ac tive Three Phase C O N C E P T I O N. UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES
O E P T I O ulti c tive Three Phase UPS (Uninterruptible Power Supply) Digital Signal Processor ODOS LIERES ODOS LIERES E Innovation, quality, technology and reliability. Trademarks of omandos Lineares
More informationNetworks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM
Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationNPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.
REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationNPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator
REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer
nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase
More informationRS Pro ENGLISH. Datasheet
Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393
More informationDESCRIPTION RATINGS 25 C) Note: For Mechanical Dimensions See Pages
YBERGATE YG2100/YG2110/YG2120 DESRIPTION lare s YG21XX Series DAA modules provide a complete telephone line interface circuit in a small 1.07" x 1.07" x 0.4" package. The modules provide a fast and cost
More informationMeasuring centers MC7x0 series Multifunction Meter MC740
Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationAdvantages There are many diverse advantages of a portable analyzer for the user. The most important is information.
Portable s CIRCUTOR offers a wide range of portable analyzers designed to measure, display and/or record the most important parameters of an electrical network. With the analysis of the electrical parameters,
More informationnew! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485
new! nd40 - power network analyzer / recorder Measurement and recording of over 500 electric energy quality parameters acc. to en 50160, en 61000-4-30, en 6100-4-7 standards. Measuring class a - for 3
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationSUBJECT TO CHANGE WITHOUT NOTICE
TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers
More informationPower Quality Analyzer / High Frequency Recorder
Technical data Power Quality nalyzer / High Frequency Recorder Model PQ-Box 300 1 Fault detection 1 Evaluation of voltage quality according to EN50160 und IEC61000-2-2/-2-4 1 Permanent FFT nalysis from
More informationTransienten. Datenspeicher
25. 40. 63. Grenzwertüberwachung Oberschwingungen Power quality RCM Residual current monitoring Transienten Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management 32 MB 128 MB
More informationImprove asset protection and utilization
QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause
More informationME432 Three-phase Power Meter
ME432 Three-phase Power Meter Connectivity advantages MODEL ME432 Support Extra sensor Programmable digital output I/O function 333mV CT Rogowski coil Relay 1*digital output Power 85~265V AC/DC 1 Feature
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationRTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03
Multimeter 560CVD03 Without LCD Display There are several versions available: With LCD Display Figure 1 Type Display LO HI 1A 5A Versions R0031 3U3I x x x R0035 3U3I x x x R0051 3U3I x x x R0055 3U3I x
More informationAS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis
Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis HIGH PERFORMANCE ACQUISITION The AS-1250FE is a high performance, compact and flexible data acquisition hardware platform
More informationDRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationPQM3000R Class A network analyzer according to EN for power quality monitoring
Class A network analyzer according to EN 50160 for power quality monitoring Possibility to carry out parameter recording according to EN 50160 Integrated web server for complete device management 4 GB
More informationC series Product brief
Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationPD140FNT60QMU-02C. Through Beam. Main features. Description
Through eam Description The PD140 sensor consists of an emitter, which sends out invisible, infrared light, and a receiver, capable of detecting the light from the emitter. The sensor is encapsulated in
More information3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments
2001 3196 POWER QUALITY ANALYZER Power Measuring Instruments Solve All Your Power Quality Problems ISO14001 JQA-E-90091 1 Identify power anomalies simply and surely! Problems in power quality that can
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationnd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485
cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase
More informationHarmonic Correction Unit NEMA 1 Enclosure
ffective: June 2001 Page 1 New Information Harmonic orrection Unit ontents Description Page Harmonic orrection Unit Specifications.......... 2 Sizing and Selection.............................................
More informationT 1000 PLUS Secondary Injection Relay Test Set
Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory
More informationnew! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS
new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320
More informationFluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data
Fluke 1735 Three-Phase Power Logger Technical Data Electrical load studies, energy consumption testing, and general power quality logging The Fluke 1735 Three-Phase Power Logger is the ideal electrician
More informationApplication and features
Power Measurement Unit PM 2214 Power Measurement Unit PM 2214 Application and features PM 2214 Power supervision / SCADA system Feeder automation / Customized 0.05% high accuracy Cost saving for 4 feeder
More information7SD/7SH/7SM Temperature Controllers
7SD/7SH/7SM Temperature ADVANTAGE EZ Series 7SD, 7SH, 7SM 1/16 DIN Temperature 3Digit LED Display Thermocouple and RTD Input Autotuning NEMA 4X Field onfigurable 100 to 40 Vac Switching Power Supply Programmable
More information