Specifications and Dimensions
|
|
- MargaretMargaret Hodges
- 5 years ago
- Views:
Transcription
1 Specifications and Dimensions Specifications and Dimensions Appendix E E-1 Introduction A brief review of AD operation may help you understand the specifications listed in this section. NOTE The specifications and dimensions listed in this section are subject to change without notice. The AD emits an acoustic pulse called a ING. Scatterers that float ambiently with the water currents reflect some of the energy from the ping back to the AD. The AD uses the return signal to calculate a velocity. The energy in this signal is the echo intensity. Echo intensity is sometimes used to determine information about the scatterers. The velocity calculated from each ping has a statistical uncertainty; however, each ping is an independent sample. The AD reduces this statistical uncertainty by averaging a collection of pings. A collection of pings averaged together is an ensemble. The AD s maximum ping rate limits the time required to reduce the statistical uncertainty to acceptable levels. The AD does not measure velocity at a single point; it measures velocities throughout the water column. The AD measures velocities from its transducer head to a specified range and divides this range into uniform segments called depth cells (or bins). The collection of depth cells yields a profile. The AD produces two profiles, one for velocity and one for echo intensity. The AD calculates velocity data relative to the AD. The velocity data has both speed and direction information. If the AD is moving, and is within range of the bottom, it can obtain a velocity from returns off the bottom. This is called bottom-tracking. The bottom-track information can be used to calculate the absolute velocity of the water. The AD can get absolute direction information from a heading sensor. Table E-1 through Table E-18 lists the specifications for all roadband DR/S AD models. About the specifications: a. All these specifications assume minimal AD motion - pitch, roll, heave, rotation, and translation. DR/S Technical Manual (March 1997) E-1
2 Appendix E b. Except where noted, this specification table applies to typical setups and conditions. Typical setups use the default input values for each parameter (exceptions include ings er Ensemble and Number of Depth ells). Typical conditions assume uniform seawater velocities at a given depth, moderate shear, moderate AD motion, and typical echo intensity levels. c. The total measurement error of the AD is the sum of: Long-term instrument error (as limited by instrument accuracy). The remaining statistical uncertainty after averaging. Errors introduced by measurement of AD heading and motion. d. ecause individual pings are independent, the statistical uncertainty of the measurement can be reduced according to the equation: Statistical uncertainity for one ping number of pings E-2 roadband AD Specifications Table E-1. Available roadband Models Model Frequency 20º oncave 30º oncave 20º onvex 30º onvex DR/S 75 X X 150 X X 300 X X 300/600* X X 600 X X 600* X X 1200 X X X X DR/S 5-EAM 600 X X *Special (smaller ceramic) Table E-2. roadband Frequency options System (khz) Actual (Hz) 76, , , ,400 1,228,800 E-2.1 Water Velocity Measurements Relative to the AD Table E-3. General roadband Water Velocity Measurement Specifications Accuracy (long-term) 0.2% of measured velocity ±0.2 cm/s Number of depth cells 1 to 128 cells Depth cell size 5 to 3200 centimeters ( 2 inches to 105 feet) E-2 DR/S Technical Manual (March 1997)
3 Specifications and Dimensions Velocity range ±10 m/s (horizontal) Table E-4. roadband recision (cm/s) Depth cell size (m) Water-current velocity precision is the statistical uncertainty (1σ) of the horizontal velocities for single pings when operating in the normal mode. The precision will decrease proportional to the square root of the number of pings averaged together. Higher precision profiling modes can be used when current shear and instrument dynamics are low. Table E-5. roadband Minimum Time etween ings (seconds) System frequency (khz) ased on 1.57 ms nominal bottom-track range DR/S Technical Manual (March 1997) E-3
4 Appendix E Table E-6. roadband Maximum rofiling Range (meters) Frequency (khz) eamwidth (degrees) Depth cell size (m) High-power mode Low-power mode Ranges are for systems using the indicated frequency, transducer beamwidth, depth cell size, and power mode in typical water conditions. Range decreases about 10% each time cell size is halved. Table E-7. roadband Minimum Range to Start of First Depth ell (meters) System frequency (khz) Table E-8. roadband Loss of rofiling Range Near a oundary 30 beam angle 13.4% of range to boundary + one depth cell 20 beam angle 6% of range to boundary + one depth cell NOTE: AD pitch and roll may reduce range. E-4 DR/S Technical Manual (March 1997)
5 Specifications and Dimensions E-2.2 AD Velocity Measurements Relative to the ottom and ottom Depth Measurements Table E-9. roadband General ottom-track Specifications Accuracy (long-term) recision (cm/s) 0.2% of measured velocity ±0.2 cm/s V + (a V)/(1 + baf), where: a = 1 cm/s b = khz 1 m 1 A = Altitude in Meters F = System Frequency in khz V = Velocity in cm/s Altitude accuracy (meters) Velocity range 1% of measured altitude ±120/Frequency (khz) ± 10 m/s (horizontal) Note: bottom-track velocity precision is the statistical uncertainty (1σ) of the horizontal velocities for single pings when operating in the normal mode. The precision will decrease proportional to the square root of the number of pings averaged together. Table E-10. roadband Maximum and Minimum Altitudes (meters) Frequency (khz) eamwidth (degrees) Max. altitudes High-power mode Low-power mode Min. altitudes Altitudes are for systems using the indicated frequency, transducer beamwidth, and power mode in typical seawater conditions. E-2.3 Echo Intensity Measurements Table E-11. Accuracy roadband Echo Intensity Specifications ±2 d rofiling range (meters) Number of depth cells Depth cell size Dynamic range 85% of water-profiling range 1 to 128 cells 5 to 3200 centimeters ( 2 inches to 105 feet) 80 d DR/S Technical Manual (March 1997) E-5
6 Appendix E E-2.4 Table E-12. Interface Input data format Data ommunication S data storage capacity (Standard) S data storage capacity (Optional) roadband Data ommunications Specifications Serial communications at 300 to 115,200 baud using two RS-422 cables, or one RS-232 cable and one RS-422 cable (see Appendix-A) ASII commands (see Appendix-) 10 to 80 megabytes of solid-state memory 90 to 320 megabytes of solid-state memory. This optional unit fits into the power module section of the S-AD and takes up to 72 millimeters of space. You may use either the standard solid state memory or the optional memory pack. The units may not be combined. E-2.5 ower Table E-13. roadband ower Specifications Deck box external power 20 to 60 VD 98 to 264 VA, Hz 12 VD External (DR models) 20 to 60 VD Internal (S models) Alkaline battery packs supplying 45 to 60 VD Table E-14. roadband Dissipation (watts) Source / Mode Standby Operate VD - High-power VD - Low-power VD A - High-power A - Low-power E-6 DR/S Technical Manual (March 1997)
7 Specifications and Dimensions E-2.6 Table E-15. Sensors roadband Internal Sensor Specifications Sensor Accuracy Resolution Heading *±5 0.2 Tilt ± Temperature ± Depth ±1% FS 0.03% FS 10 to 10,000-m full-scale (fs) depth sensors available. Heading accuracy assumes you are working in an environment where the horizontal magnetic field strength is 10,000 to 40,000 nt (nano-teslas) and the operational temperature of External Sensors - RS-485 serial interface at baud (future) E-2.7 Table E-16. Temperature Humidity Environmental roadband Environmental Specifications Operating: -5 to +35 Storage : -50 to +80 Must be non-condensing Vibration Meets MIL-STD-167-1, type 1 Shock DR/S depth ratings 20 g static 200 m, 1000 m, 3000 m, or 6000 m DR/S Technical Manual (March 1997) E-7
8 Appendix E E-2.8 roadband AD hysical haracteristics NOTE See outline drawings for dimensions and weights for specific AD frequencies. TRANSDUER TRONIS TRONIS HASSIS OWER MODULES 4-EAM SEE OUTLINE DRAWINGS AND WEIGHT TALE (ONAVE) (ONVEX) WEIGHT = 1.45 kg (3.2 lbs) WEIGHT = 3.13 kg (6.9 lbs) EXANDALE MAX WEIGHT= 4.7 kg (10.5 lbs) TRANSDUER TRONIS TRONIS HASSIS OWER MODULES 5-EAM SEE OUTLINE DRAWINGS AND WEIGHT TALE kg (3.2lbs) kg (6.9 lbs) EXANDALE MAX WEIGHT = 4.7 kg (10.5 lbs) Figure E-1. roadband Electronics hassis Dimensions Overview E-8 DR/S Technical Manual (March 1997)
9 Specifications and Dimensions Table E-17. roadband ower Module Dimensions and Weights Description Width (mm) Weight (kg) apacitor bank Hi-ower module ower conditioner module (earlier Revision ADs) ower conditioner module Single battery pack module Double battery pack module Triple battery pack module Single battery pack (earlier revision ADs) Optional memory module (up to 160 M) Optional memory module (up to 320 M) DR-AD Slider late (earlier revision ADs) S-AD Slider plate (earlier revision ADs) Latch Lock bracket N/A Slider rail N/A /mm NOTE See configuration drawings for power module locations. 483 mm (19.0 in.) mm (17.5 in.) 88.9 mm (3.5 in.) (FRONT) (RIGHT SIDE) Figure E-2. DR-AD Deck ox Dimensions (Earlier Revision Deck ox) NOTE See outline/installation drawing for dimensions of present deck box. DR/S Technical Manual (March 1997) E-9
10 Appendix E E-2.9 roadband AD Standard onfiguration Drawings S-AD users may convert their systems to a DR-AD configuration by installing the following components: DR-AD end cap DR-AD slider plate (if your AD uses a slider plate) apacitor banks See the configuration drawings for standard configurations. The order in which the modules are placed is important: Do not change. LEGEND = OWER ONDITIONER = ATTERY AK N = ART NUMER HIGH OWER TRONIS N -02 TRONIS A ANK A ANK A ANK A ANK HIGH A A OWER ANK ANK N -02 LUE WATER 75 S ONFIGURATION SHOWN Number of battery packs ressure ase Length (mm) LUE WATER 75 WITH DR ONVERSION DR ONFIGURATION SHOWN Minimum ressure ase Length = 1060mm HIGH TRONIS OWER N -02 A TRONIS ANK A ANK HIGH A OWER ANK N -02 Figure E-3. LUE WATER 150 S ONFIGURATION SHOWN Number of battery packs ressure ase Length (mm) lue Water Systems Standard onfiguration LUE WATER 150 WITH DR ONVERSION DR ONFIGURATION SHOWN Minimum ressure ase Length = 1060mm E-10 DR/S Technical Manual (March 1997)
11 Specifications and Dimensions LEGEND = OWER ONDITIONER = ATTERY AK N = ART NUMER TRONIS A TRONIS ANK A ANK A ANK HIGH OWER N -02 ONTINENTAL SHELF 150 S ONFIGURATION SHOWN Number of battery packs ressure ase Length (mm) ONTINENTAL SHELF 150 WITH DR ONVERSION DR ONFIGURATION SHOWN Minimum ressure ase Length = 830 (mm) TRONIS A TRONIS ANK ONTINENTAL SHELF 300 S ONFIGURATION SHOWN Number of battery packs ressure ase Length (mm) ONTINENTAL SHELF 300 WITH DR ONVERSION DR ONFIGURATION SHOWN Minimum ressure ase Length = 830 (mm) TRONIS TRONIS ONTINENTAL SHELF 1200/600 S ONFIGURATION SHOWN Number of battery packs ressure ase Length (mm) ONTINENTAL SHELF 1200/600 WITH DR ONVERSION DR ONFIGURATION SHOWN Minimum ressure ase Length = 830 (mm) Figure E-4. ontinental Shelf Systems Standard onfiguration DR/S Technical Manual (March 1997) E-11
12 Appendix E LEGEND = OWER ONDITIONER = ATTERY AK N = ART NUMER TRONIS A A A A A A ANK ANK ANK ANK ANK ANK HIGH OWER N -03 DR75 TRONIS A ANK A ANK A ANK HIGH OWER N -03 DR150 TRONIS A ANK DR300 TRONIS DR2400/1200/600 Figure E-5. Direct-Reading Systems Standard onfigurations E-12 DR/S Technical Manual (March 1997)
13 Specifications and Dimensions LEGEND = OWER ONDITIONER = ATTERY AK N = ART NUMER TRONIS ALL ONTINENTAL SHELF SYSTEMS Number of battery packs ressure ase Length (mm) TRONIS HIGH OWER N-02 LUE WATER 75/150 Number of battery packs ressure ase Length (mm) Figure E-6. Self-ontained Systems Standard onfiguration DR/S Technical Manual (March 1997) E-13
14 Appendix E E-2.10 Outline Installation Drawings Table E-18. Outline Installation Drawings Description Drawing Number DR/S 1200kHz 20 oncave DR/S 1200kHz 30 oncave DR/S 1200kHz 20 onvex DR/S 1200kHz 30 onvex DR/S 600kHz 20 onvex, small ceramic DR/S 600kHz 30 onvex, small ceramic DR/S 600kHz 20 onvex DR/S 60kHz 30 onvex DR/S 300/600kHz 20 oncave, small ceramic DR/S 300/600kHz 30 oncave, small ceramic DR/S 300kHz 20 onvex DR/S 300kHz 30 onvex DR/S 150kHz 20 onvex DR/S 150kHz 30 onvex DR/S 75kHz 20 onvex DR/S 75kHz 30 onvex DR/S 600kHz 30 onvex, 5-beam DR/S 600kHz 20 onvex, 5-beam DR/S 1000 meter ressure ase DR/S 3000/6000 meter ressure ase DR/S 90 Adapter Elbow DR Deck ox E-14 DR/S Technical Manual (March 1997)
Mean currents and turbulence, plus wave height, direction and ice tracking
Mean currents and turbulence, plus wave height, direction and ice tracking The ADCP is designed for flexibility. It measures current profiles at up to 8 Hz sampling frequency. It can also measure direct
More informationAquadopp Profiler 2 MHz
Small and compact, short-range current profiling; option for PUV wave measurements The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in four profiling range
More informationReal-time current profiles and directional waves for intermediate water
Real-time current profiles and directional waves for intermediate water The AWAC 600 khz ADCP has become the standard reference technology in submerged wavemeasurement applications. Thousands of these
More informationThe Signature VM package delivers vessel-mounted AD2CP capabilities based on present-day technology
The package delivers vessel-mounted AD2CP capabilities based on present-day technology Until now, ADCP current surveys have been complex and time-consuming processes. A successful current survey depends
More informationPhased Array Velocity Sensor Operational Advantages and Data Analysis
Phased Array Velocity Sensor Operational Advantages and Data Analysis Matt Burdyny, Omer Poroy and Dr. Peter Spain Abstract - In recent years the underwater navigation industry has expanded into more diverse
More informationDesign Characteristics. FlexDrive II. Series
AC AC DC DC FlexDrive II Series Design Characteristics Brushless AC Servo Baldor s FlexDrive II series are designed to provide reliable and durable operation. Options are available to operate either resolver
More informationAdvanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CIBANO 500 3-in-1 test system for medium- and high-voltage circuit breakers Medium- and high-voltage circuit breaker
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field
More informationSPEEDBOX Technical Datasheet
SPEEDBOX Technical Datasheet Race Technology Limited, 2008 Version 1.1 1. Introduction... 3 1.1. Product Overview... 3 1.2. Applications... 3 1.3. Standard Features... 3 2. Port / Connector details...
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationOPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO
OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO. 990-60700-9801 GEOTECH INSTRUMENTS, LLC 10755 SANDEN DRIVE DALLAS, TEXAS 75238-1336 TEL: (214) 221-0000 FAX: (214) 343-4400
More informationExperiment P11: Newton's Second Law Constant Force (Force Sensor, Motion Sensor)
PASCO scientific Physics Lab Manual: P11-1 Experiment P11: Newton's Second Law Constant Force (Force Sensor, Motion Sensor) Concept Time SW Interface Macintosh file Windows file Newton s Laws 30 m 500
More informationExposure Level Tester ELT-400
Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various
More informationLaboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor
Laboratory Grade Instruments 4020 Series & 4021 Power Meter Semiconductor 4020 SERIES Power Sensor 4021 4022 4024 4025 Power Input 300 mw to 1 kw 300 mw to 1 kw 3 W to 10 kw 3 W to 10 kw (1.2 kw max.)
More informationREVOLUTIONIZING LONG RANGE CURRENT PROFILING BROADBAND SERIES TRUE INNOVATION MAKES A DIFFERENCE
REVOLUTIONIZING LONG RANGE CURRENT PROFILING BROADBAND SERIES TRUE INNOVATION MAKES A DIFFERENCE - REVOLUTIONIZING LONG RANGE CURRENT PROFILING Nortek is pleased to introduce the Signature55, a dual frequency
More informationSection 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5
LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section
More information27/11/2013' OCEANOGRAPHIC APPLICATIONS. Acoustic Current Meters
egm502 seafloor mapping lecture 17 water column applications OCEANOGRAPHIC APPLICATIONS Acoustic Current Meters An acoustic current meter is a set of transducers fixed in a frame. Acoustic current meters
More informationGS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application
Features Crane Slew-Angle Wireless Measurement Sensor Resolution of 0.1 Accuracy: typical: 0.5 over 360 Range: 0 to 360 Rugged water proof enclosure IP66 Potted electronics for increased water protection
More informationLow Frequency Coherent Source Sonobuoy
Low Frequency Coherent Source Sonobuoy Active Source The Low Frequency Coherent Source (LFCS) is NATO, A-size sonobuoy manufactured by STS for use as a source in a multi-static field. The LFCS is capable
More informationGE AMX 4+ Portable X-Ray
GE AMX 4+ Portable X-Ray Typical Manufacturer s Picture GE Healthcare s AMX-4+ analog X-ray system provides high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More informationULTRAVOLT HIGH-POWER C SERIES HIGH VOLTAGE CAP-CHARGING SUPPLY
ULTRAVOLT HIGH-POWER C SERIES HIGH VOLTAGE CAP-CHARGING SUPPLY High voltage cap-charging supplies The high-power line of high voltage regulated DCto-DC converters is an extension of the C series, directly
More informationTemposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Analog and Start/Stop Outputs SENSORS Document Part Number: 550996 Revision E Data Sheet FEATURES Linear, Absolute Measurement
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationC B. Models. Models 2MOPP
AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to
More informationKU-BAND OUTDOOR BLOCK CONVERTERS
Features/Options Low Phase Noise Exceeds IESS 308/309 25 db L-Band Gain Control with 0.1 db Step Auto Switch Over to an Internal High Stability REF Internal REF Tune to Match with External
More informationExercise 1-4. The Radar Equation EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS
Exercise 1-4 The Radar Equation EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the different parameters in the radar equation, and with the interaction between these
More informationINSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.
INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL 5012 Copyright 2008 by Bird Electronic Corporation Instruction Book P/N 920-5012 Rev. C Description The Bird 5012 Wideband Power Sensor (WPS) is a Thruline
More informationAgilent U2000 Series USB Power Sensors. Data Sheet
Agilent U2000 Series USB Power Sensors Data Sheet Features Perform power measurement without a power meter Frequency range from 9 khz to 24 GHz (sensor dependent) Dynamic range from 60 dbm to +20 dbm Internal
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER SSI Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationAPPENDIX APPENDIX A 1
A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More informationHigh Power Outdoor. GaN Solid State Power Amplifiers
Teledyne Paradise Datacom s newly packaged High Power Outdoor (H) series of Solid State Power Amplifiers is packaged with the latest Gallium Nitride, GaN, based SSPA modules. Utilizing the latest in linearized
More informationPRINCIPLE OF SEISMIC SURVEY
PRINCIPLE OF SEISMIC SURVEY MARINE INSTITUTE Galway, Ireland 29th April 2016 Laurent MATTIO Contents 2 Principle of seismic survey Objective of seismic survey Acquisition chain Wave propagation Different
More informationAgilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz
Agilent 87C/D/E Coaxial Transfer Switches dc to 6.5, 0, 50 GHz Technical Overview High Performance Transfer Switches for Micro wave and RF Instrumentation and Systems Exceptional repeatability for more
More informationUltrasonic Level Transducer Type: MPUL06 Article No.: ca. 122
Type: Article No.: 0067720.006 Dimensions ø95 PG7 45.25 16 101 ca. 122 ø53 NPS 2" Figure 1: Ultrasonic Level Transducer Description and application The MPULxx is an ultrasonic transducer used for determining
More informationThis manual describes the Motion Sensor hardware and the locally written software that interfaces to it.
Motion Sensor Manual This manual describes the Motion Sensor hardware and the locally written software that interfaces to it. Hardware Our detectors are the Motion Sensor II (Pasco CI-6742). Calling this
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER Start / Stop Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear
More informationSYSTEM 5900 SIDE SCAN SONAR
SYSTEM 5900 SIDE SCAN SONAR HIGH-RESOLUTION, DYNAMICALLY FOCUSED, MULTI-BEAM SIDE SCAN SONAR Klein Marine System s 5900 sonar is the flagship in our exclusive family of multi-beam technology-based side
More informationULTRAVOLT HIGH-POWER C SERIES
HIGH VOLTAGE CAP-CHARGING SUPPLY The Ultravolt high-power line of high voltage regulated DC-to-DC converters is an extension of the C series, directly addressing the high power density needs of > 30 W
More informationModel 845-M Low Noise Synthesizer
Model 845-M Low Noise Synthesizer Features Low phase noise Fast switching down to 20 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency converters
More informationOX-046 VHF low g-sensitivity Oven Controlled Crystal Oscillator
OX-046 VHF low g-sensitivity Oven Controlled Crystal Oscillator OX-046 Features Ultra Low G-Sensitivity Low Phase Noise Very High Frequency Frequency Range: 50 MHZ to 250 MHZ Standard Frequency: 100 MHz
More informationMotion Reference Units
Motion Reference Units MRU Datasheet Rev. 1.3 IP-67 sealed 5% / 5 cm Heave accuracy 0.03 m/sec Velocity accuracy 0.05 deg Pitch and Roll accuracy 0.005 m/sec2 Acceleration accuracy 0.0002 deg/sec Angular
More informationMA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features
Page 1 of 8 Description The MA3 is a miniature rotary absolute shaft encoder that reports the shaft position over 360 with no stops or gaps. The MA3 is available with an analog or a pulse width modulated
More informationLinkAlign-60RPT Set-up and Operation Manual
LinkAlign-60RPT Set-up and Operation Manual LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 1 LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 2 Description of
More informationOX-400 / OX 401 Oven Controlled Crystal Oscillator
OX-400 / OX 401 Oven Controlled Crystal Oscillator OX-400 / 401 Features 4-Pin Dip Fast warm-up TCXO replacement for better short term stability Frequency Range, 10 MHz to 40 MHz Standard frequencies,
More informationGPS-Aided INS Datasheet Rev. 3.0
1 GPS-Aided INS The Inertial Labs Single and Dual Antenna GPS-Aided Inertial Navigation System INS is new generation of fully-integrated, combined GPS, GLONASS, GALILEO, QZSS, BEIDOU and L-Band navigation
More informationKu-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.
200W Outdoor TWT Amplifier for Satellite Communications The T02UO-2G 200 Watt TWT Power Amplifier higher efficiency in an environmentally sealed compact package designed for outdoor operation Less Prime
More informationPOSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire
Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute
More informationULTRAVOLT BIPOLAR HIGH POWER C SERIES
DUAL-OUTPUT HIGH VOLTAGE POWER SUPPLIES The UltraVolt bipolar C series line of regulated DC-to-DC high voltage converters is an extension of the high power C series. Bipolar C series units contain a pair
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157 Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.
More informationTORSTEIN PEDERSEN. Improving the Common DVL: A New Standard in Doppler Velocity Logs
TORSTEIN PEDERSEN Improving the Common DVL: A New Standard in Doppler Velocity Logs VOLVO OCEAN RACE 2011 Precursor to Nortek s DVL story Nortek Background for DVLs Technology Company with expertise in
More informationBW-IMU200 Serials. Low-cost Inertial Measurement Unit. Technical Manual
Serials Low-cost Inertial Measurement Unit Technical Manual Introduction As a low-cost inertial measurement sensor, the BW-IMU200 measures the attitude parameters of the motion carrier (roll angle, pitch
More informationHouston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500
Houston Radar LLC Installation and User Manual For Doppler Radar DR-1500 Houston Radar LLC 13814 Sherburn Manor Dr. Cypress.TX Http://www.Houston-Radar.com Email: sales@houston-radar.com Contact: (281)
More informationULTRASONIC LEVEL INDICATOR
ULTRASONIC LEVEL INDICATOR REFLEX/SCANFLEX MULTIFLEX MINIFLEX LR MICROFLEX-C TYPICAL NON-CONTACT LEVEL METER! OUTSTANDING SOFWARE MAKES HIGHLY STABLE AND RELIABLE. A WIDE RANGE OF S FROM SOLIDS TOLIQUIDS,
More informationPrinciples of Operation A Practical Primer
Acoustic Doppler Current Profiler Principles of Operation A Practical Primer Second Edition for Broadband ADCPs by: R. Lee Gordon 9855 Businesspark Ave. San Diego, California 92131 USA Phone: 619-693-1178
More informationGPS-Aided INS Datasheet Rev. 2.7
1 The Inertial Labs Single and Dual Antenna GPS-Aided Inertial Navigation System INS is new generation of fully-integrated, combined GPS, GLONASS, GALILEO, QZSS and BEIDOU navigation and highperformance
More informationFeatures. Electrical Outputs Complementary outputs: A, A, B, B, I, I I and I available only on three channel encoders
HEDL-550x/554x, HEDL-560x/564x, HEDL-9000/90, HEDL-9040/9140/ 92xx Encoder Line Drivers Data Sheet Description Line Drivers are available for the HEDS-55xx/56xx series and the HEDS-9000/90/9200/9040/9140
More informationCurrent / residual current and voltage transformers. Current / residual current and voltage transformers
Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationAppendix B. Argonaut-SL Principles of Operation
Appendix B. Argonaut-SL Principles of Operation SonTek/YSI, Inc. This Argonaut-SL System Manual appendix provides an introduction to the operating principles of the SonTek/YSI Argonaut Side-Looking (SL)
More informationTITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.
PART NUMBER SELECTION Models: 2: Without 50 Ω terminations 4: With 50 Ω terminations RF Connectors: 3: SMA up to 6 GHz 4: SMA up to 20 GHz F: SMA up to 26.5 GHz 8: SMA 2.9 up to 40 GHz (1) Radiall s TITANIUM
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER IO-Link Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationThe Discussion of this exercise covers the following points:
Exercise 3-2 Frequency-Modulated CW Radar EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with FM ranging using frequency-modulated continuous-wave (FM-CW) radar. DISCUSSION
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 550A Getting Started Supplement Issue: Part Number: 415509 Issue Date: 9/18 Print Date: November 01 Page Count: 19 Revision/Date: This supplement contains information necessary to ensure
More informationOX-043 Low g-sensitivity Oven Controlled Crystal Oscillator
OX-043 Low g-sensitivity Oven Controlled Crystal Oscillator OX-043 Features Applications Ultra Low g-sensitivity Low Phase Noise High Stability Frequency Range: 8 MHZ to 15 MHZ Standard Frequency 10 MHz
More informationMA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Mechanical Drawing. Features
Description Page 1 of 8 The MA3 is a miniature rotary absolute shaft encoder that reports the shaft position over 360 with no stops or gaps. The MA3 is available with an analog or a pulse width modulated
More information11. Lowered Acoustic Doppler Current Profiler (LADCP)
11. Lowered Acoustic Doppler Current Profiler (LADCP) 11.1 Instrument Setup The JC031 Drake Passage cruise began in Punta Arenas equipped with a compliment of 3 fully functioning LADCP s, all the same
More informationSL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual
USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit
More informationCONDOR C1216 GPS RECEIVER MODULE technical notes ZELIA INTEGRATES ANTENNA, GPS RECEIVER, RTC AND LNA
CONDOR C1216 GPS RECEIVER MODULE technical notes Zelia GPS RECEIVER MODULE TECHNICAL HIGHLIGHTS Integrated antenna element, GPS receiver, real-time clock, and low noise amplifier Receiver: Trimble Condor
More informationOX-304 at 10 MHz Ultra Low Phase Noise Oven Controlled Crystal Oscillator
OX-304 at 10 MHz Ultra Low Phase Noise Oven Controlled Crystal Oscillator OX-304 The OX-304 is an Ultra Low Phase Noise Ovenized Crystal Oscillator with a noise floor as low as -173 dbc/hz in a compact
More information3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement
Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and
More informationThe quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.
Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly
More informationDP Operator Course Training Manual HPR
- Hydroacoustic Position Reference System consists of transducer(s) onboard a vessel communicating with transponder(s) placed on the seabed. The transducers are lowered beneath the hull, and when a transponder
More informationCharge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...
Electronics & Software Charge Meter Type 5015A... Universally Applicable for Piezoelectric Measuring Technology This instrument can be used wherever mechanical quantities are measured with piezoelectric
More informationNavigator I J40-X15SC OEM Laser System 1064nm, 532nm, 355nm, and 266nm
Navigator I J40-X15SC OEM Laser System 1064nm, 532nm, 355nm, and 266nm The Navigator I X15SC laser system is an advanced diode pumped solid state laser system. Its Q-switched output characteristics have
More informationDynamic Angle Estimation
Dynamic Angle Estimation with Inertial MEMS Analog Devices Bob Scannell Mark Looney Agenda Sensor to angle basics Accelerometer basics Accelerometer behaviors Gyroscope basics Gyroscope behaviors Key factors
More informationTD 304 OPERATING MANUAL Doppler Current Profiler Sensor December 2015 DCPS 5400 / 5402 / 5403
TD 304 OPERATING MANUAL Doppler Current Profiler Sensor December 2015 Doppler Current Profiler Sensor DCPS 5400 / 5402 / 5403 Page 2 December 2015 TD 304 OPERATING MANUAL Doppler Current Profiler Sensor
More informationUltrasonic Level Transmitters (Optional Exercise)
Exercise 4-6 Ultrasonic Level Transmitters (Optional Exercise) EXERCISE OBJECTIVE In this exercise, you will study how ultrasonic level transmitters operate. You will measure level in a column using an
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More information5520A. Multi-Product Calibrator. Extended Specifications 2005
5520A Multi-Product Calibrator Extended Specifications 2005 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,
More informationPanaray 302 A TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications. Bose Professional Systems Division 1 OF 6
Key Features Articulated Array design provides wide 175 x 90 coverage to deliver wide-range reproduction over a broad dispersion area Two-way design with 5.25" (133 mm) woofer and two 2.5" (64 mm) drivers
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationPOSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire
POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124 Picture of product with pencil Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low
More informationMotion Reference Units
Motion Reference Units MRU IP-67 sealed 5% / 5 cm Heave accuracy 0.03 m/sec Velocity accuracy 0.05 deg Pitch and Roll accuracy 0.005 m/sec 2 Acceleration accuracy 0.0002 deg/sec Angular rate accuracy NMEA
More informationVarious Technics of Liquids and Solids Level Measurements (Part 4)
(Part 4) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,
More informationDF Absolute position, rotary Electric Encoder
F-60-2017-02, May 2017 F-60-2 bsolute position, rotary lectric ncoder The F-60 is a member of the F series of lectric ncoders, based on Netzer Precision proprietary technology. The lectric ncoder offers
More informationAgilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet
Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz Data Sheet Table of Contents Definitions... 2 FieldFox RF Vector Network Analyzer... 3 Cable and Antenna Analyzer (Option 305)... External
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER SSI Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Secondary calibration of acoustic emission sensors
INTERNATIONAL STANDARD ISO 12714 First edition 1999-07-15 Non-destructive testing Acoustic emission inspection Secondary calibration of acoustic emission sensors Essais non destructifs Contrôle par émission
More informationDAVIS ANEMOMETER MODBUS INTERFACE MODULE DA485. Manual. Pages 10
DAVIS ANEMOMETER MODBUS INTERFACE MODULE DA485 Manual Pages 10 Сontent 1 Description and Operation of the Product... 3 1.1 Product Designation... 3 1.2 Technical Specifications... 3 1.3 Technology and
More informationAgilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet
Agilent N1911A/N191A P-Series Power Meters and N191A/N19A Wideband Power Sensors Data sheet Specification Definitions There are two types of product specifications: Warranted specifications are specifications
More informationMODELS SM SERVOTUBE MODULE
Force» Peak: 46-92 N» Continuous: 6-27 N Maximum Velocity» Up to 10.8 m/s Feedback» Built-in position sensor» 1V pk-pk sin/cos» 6 micron repeatability» Optionally with high resolution encoder Range of
More informationModel FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter
Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------
More informationHigh-Reliability and Environment Qualified Components
High-Reliability and Environment Qualified Components Introduction Ruggedness and reliability have been designed in across our product lines and proven in the field. This section of our catalog provides
More informationHTTF Transit Time Ultrasonic Flow Meter
Transit Time Ultrasonic Flow Meter Reduced material costs: clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers, and filters Reduced installation time: the may be installed
More information