1 LinkAlign-60RPT Set-up and Operation Manual LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 1

2 LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 2

3 Description of items included with a LinkAlign360-RPT... 4 General Notes:... 4 LinkAlign360-RPT Details... 5 Quick steps for Setup and Operation of the LinkAlign-360RPT antenna positioner... 7 LinkAlign User interface details Manual Controls window... 12, 14 Target Position window GPS window Settings Page IP Reset instructions... 21, 22 LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 3

4 General Notes: This document provides set-up and operation instructions for the LinkAlign60-RPT. The manual does not cover installation of the antenna or radio which will vary with each user. Warnings: Pinch point hazard: The LinkAlign antenna positioner has potential pinch points while the system is in operation. Maintain a safe distance from the positioner while any axis is in motion. 48VDC present of PoE injector. Take care when installing Ethernet cables between computer and LinkAlign Antenna positioner. The PoE injector has two RJ-45 connectors. One RJ-45 has both 48VDC power and Ethernet present. Take extra precaution when plugging computer and positioner side cables into PoE injector. Do not exceed 2 foot antenna aperture sizes with the LinkAlign-60RPT. The positioner is designed to handle any commercial antenna with a solid panel and surface area of 2 feet high by 2 feet wide or 2 foot round diameter. Consult Nextmove Technologies for aperture sizes greater than these dimensions. Description of items included with a LinkAlign-360RPT The pictures and table below identify what is included with a LinkAlign360-RPT Callout Callout Description number 1 LinkAlign-60RPT positioner with embedded controller and web based user interface installed. The LinkAlign- 60RPT has ±30º of Azimuth range of motion and ±7.5º of Elevation range of motion foot Power over Ethernet (PoE) power and control cable. Connects between the LinkAlign antenna positioner and item 3 PoE power injector 3 Power over Ethernet (PoE) injector. Injection point of 48VDC power to provide 48 volts DC to the LinkAlign antenna positioner watt, 48V DC power supply. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 4

5 LinkAlign-360RPT Details The pictures and table in this section identify and describe each feature of the LinkAlign-60RPT positioner. Additional details can be found in the LinkAlign-60RPT mechanical ICD (ICDN900198) Bottom View Installed on Pole Callout Callout Description number 1 Handle which allows for easy installation and transportation of the LinkAlign-60RPT. 2 RPT60 Quick mount plate. Provides easy installation of the LinkAlign-RPT60. The quick mount plate adapts to the LinkAlign postioner and provides a mechanical interface for pipe mount ranging from 2 inches to 6 inches in diameter. 3 GPS antenna used by the LinkAlign antenna positioner to establish current location. Used by software to automate the set up of an antenna link. 4 LinkAlign antenna controller. 5 Azimuth linear actuator. 6 Elevation linear actuator. 7 Hand knob fasteners. 4 places. Fastens the LinkAlign- 60RPT to the quick mount bracket. Provides tool-less installation of the pan and tilt to a tower or mast. 8 Antenna mount interface for installation of antenna. See LinkAlign-60RPT mechanical ICD identified as ICDN for specific mounting surface dimensions and hole locations. Nextmove also offers antenna adapter brackets to easily adapt antennas and radios to the LinkAlign antenna postioner. Visit for more information on LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 5

6 antenna adapter brackets. 9 Connector for polarization control. An optional polarization rotator is available to work with the LinkAlign-60RPT. Visit for more information on the polarization rotator. 10 RS-485 interface for serial remote control to the LinkAlign positioner. Contact Nextmove technologies for more information. 11 Power over Ethernet (PoE) connector. Provides primary power and Ethernet connectivity to LinkAlign antenna positioner. 12 Weather tight connector for GPS antenna. This connector should always remain in place and should never be removed during normal operation. Allows for replacement of GPS antenna puck. 13 Weather tight connector for Elevation linear actuator. This connector should always remain in place and should never be removed during normal operation. Allows for replacement of elevation linear actuator. 14 Weather tight connector for azimuth linear actuator. This connector should always remain in place and should never be removed during normal operation. Allows for replacement of azimuth linear actuator. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 6

7 Steps for Setup and Operation of the LinkAlign-60RPT antenna positioner Step 1, Install the quick mount plate on pole. Mount the LinkAlign quick mount plate to a 2 inch pole using provided U-bolts. Optional U-Bolts up to 6 inches in diameter are also available. Contact Nextmove for more information. Make sure shoulder screws shown in two places are closer to the top of plate when installed on pole. U-bolts in two places. Top and bottom. Provided with LinkAlign-60RPT LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 7

8 Step 2, Install LinkAlign-60RPT on quick mount plate. Mount the LinkAlign-60RPT to quick mount plate by placing the positioner on the two shoulder screws located on the quick mount bracket that match the provided holes in the positioner. Fasten LinkAlign- 60RPT to quick mount plate using 4 hand knobs. Hand knobs Shoulder screw holds positioner on quick mount plate Step 3, Connect control cable. Connect weather tight quarter turn circular connector end of the PoE Ethernet control cable to LinkAlign positioner as shown below. Run cable through provided access hole as shown at back of unit Connect to LinkAlign- 60RPT controller Step 4, Connect PoE control cable to PoE injector Connect opposite end of Ethernet control cable to the power and data side of PoE injector as shown below. Connect DC power supply provided with PoE injector as shown below. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 8

9 PoE Cable from Positioner 48 VDC Power Supply Step 5, Connect PoE injector to Computer. Connect data side of PoE injector to a computer using a standard Ethernet cable with RJ-45 connectors at each end. This cable is not supplied with positioner. Step 6, Configure your computer IP address Configure your wired Ethernet RJ-45 connection on your computer for a static IP address. The LinkAlign antenna positioner uses the default IP address of Set the computer static IP address at as shown below. Configuring customer supplied computer for a static IP address will vary with each computer operating system. An example using windows is shown below. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 9

10 Step 7, Access control window using web browser. Log on to positioner using Google Chrome, Safari, or Mozilla Firefox. Enter the factory set static IP address of into the command line of the web browser. An authentication required window will appear in the browser as shown below. Enter the factory default user name and password called out below and select the "OK" button. Nextmove default User Name and Password. User Name: admin Password: nextmove LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 10

11 The User Interface main page will load into the browser window indicating that you are now connected to the LinkAlign antenna positioner. The table below identifies and describes each control window Callout number Callout Description 1 Manual Control Window: Provides manual control for up, down, clockwise, and counter clockwise movements of the LinkAlign antenna positioner. 2 Target Position Window: Displays current antenna positioner azimuth and elevation and optional polarization. Allows entry of a commanded azimuth, elevation, and optional polarization. 3 Settings Button: The settings button will open a separate window which allows for configuration of IP address, positioner travel limits, software version, and software updates. 4 GPS Window: Displays current latitude and longitude of antenna positioner and allows manual entry for desired target latitude and longitude to calculate a heading to target end. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 11

12 LinkAlign User interface details This section details each user control window on the main page and describes the command and status function available in each window. Manual Controls window with "Step" Function enabled Callout Callout Callout Function number Description 1 Step/Slew select This button allows the user to select between step or slew command control. The functions outlined in this table identify how the positioner will respond with "Step" selected in the manual controls window. 2 Up Arrow Moves the LinkAlign elevation antenna position in a positive direction (up) in step sizes equal to the defined step size. Each time the arrow is pressed the positioner will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in this direction is met. 3 Counter Clockwise Arrow Moves the LinkAlign azimuth antenna position in a counter clockwise direction in step sizes equal to the defined step size. Each time the arrow is pressed the positioner will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in this direction is met. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 12

13 4 Clockwise Polarization rotator control Moves the LinkAlign Polarization antenna position in a clockwise rotation equal to the defined step size. Each time the button is pressed the polarization axis will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in the clockwise polarization direction is met. (This control will only work if a polarization rotator is installed) 5 Speed control The speed control slider bar selects the velocity of the antenna positioner. The far right as shown in the manual is the fastest and the far left is the slowest. The slider bar has 4 speed locations. The speed control slider bar can change the positioner velocity range from 2º/sec, 3.75º/sec, 5º/sec, and 7 deg per second. 6 Emergency Stop button 7 Step size selection 8 Clockwise Arrow 9 Counter Clockwise Polarization rotator control The emergency stop button will stop travel in all directions when selected. Allows user defined steps sizes in degrees. User configurable step sizes are entered and the value is applied to manual arrow direction commands. Example shows 5 degrees per step. Moves the LinkAlign azimuth antenna position in a clockwise direction in step sizes equal to the defined step size. Each time the arrow is pressed the positioner will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in this direction is met. Moves the LinkAlign Polarization antenna position in a counter clockwise rotation equal to the defined step size. Each time the button is pressed the polarization axis will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in the counter clockwise polarization direction is met. (This control will only work if a polarization rotator is installed) 10 Down Arrow Moves the LinkAlign elevation antenna position in a negative (down) direction in step sizes equal to the defined step size. Each time the arrow is pressed the positioner will move by the defined step size amount and then stop. The positioner will continue to accept this command until the travel limit in this direction is met. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 13

14 Manual Controls window with "Slew" Function enabled LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 14

15 Callout Callout Callout Function number Description 1 Step/Slew select This button allows the user to select between step or slew command control. The functions outlined in this table identify how the positioner will respond with "Slew" selected in the manual controls window. 2 Up Arrow Moves the elevation axis antenna position in a positive direction (up). Press and hold the up arrow and the positioner will continue to move in an upwards direction until the travel limit is met or the directional arrow is released. 3 Counter Clockwise Arrow Moves the azimuth antenna position in a counter clockwise direction (left). Press and hold the CCW arrow and the positioner will continue to move in an CCW direction until the travel limit is met or the directional 4 Clockwise Polarization rotator control arrow is released. Moves the polarization antenna position in a clockwise direction. Press and hold the clockwise polarization button and the positioner will continue to move in an clockwise direction until the travel limit is met or the directional arrow is released. (This control will only work if a polarization rotator is installed) 5 Speed control The speed control slider bar selects the velocity of the antenna positioner. The far right as shown in the manual is the fastest and the far left is the slowest. The slider bar has 4 speed locations. The speed control slider bar can change the positioner velocity range from 2º/sec, 3.75º/sec, 5º/sec, and 7 deg per second. 6 Emergency Stop button 7 Clockwise Arrow 8 Counter Clockwise Polarization rotator control The emergency stop button will stop travel in all directions when selected. Moves the azimuth antenna position in a clockwise direction (right). Press and hold the CW arrow and the positioner will continue to move in an CW direction until the travel limit is met or the directional arrow is released. Moves the polarization antenna position in a counter clockwise direction. Press and hold the counter clockwise polarization button and the positioner will continue to move in an counter clockwise direction until the travel limit is met or the directional arrow is released. (This control will only work if a polarization rotator is installed) 9 Down Arrow Moves the elevation antenna position in a negative direction (down). Press and hold the down arrow and the positioner will continue to move in the down direction until the travel limit is met or the directional arrow is released. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 15

16 Target Position window Callout Callout Callout Function number Description 1 Current Azimuth Displays LinkAlign positioners current azimuth heading in degrees. Position 2 Current Elevation Displays LinkAlign positioners current elevation heading in degrees. Position 3 Current Polarization Displays positioners current polarization angle in degrees. (If a polarization rotator is installed) Position 4 Commanded Azimuth Accepts values in degrees to command the positioner to a desired azimuth angle. Position 5 Commanded Elevation Accepts values in degrees to command the positioner to a desired elevation angle. Position 6 Commanded Polarization Position Accepts values in degrees to command the polarization rotator to a desired polarization angle. (Requires polarization rotator (LinkAlign-360POL) to be installed) 7 Active Axis lights Indicates if an axis is active. Red = stopped (no motion) Green = go (axis in motion). 8 "Go" button Executes commanded Azimuth, Elevation, and Polarization entries. An operator may enter values into one or all of the command boxes and press the "Go" button. The positioner will then move until the desired values are satisfied. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 16

17 GPS window Callout Callout number Description 1 Current Coordinates 2 Altitude and number of Satellites Callout Function Displays the current GPS coordinates read from the antenna positioner. Displays additional GPS data identifying current altitude of the positioner and the number of satellites in view. 3 GPS Status Four color LED indicating current GPS status. Green = GPS online and working properly, Yellow = GPS is reporting data but is still collecting data to report accurate fix, Blue = GPS is reading data but GPS data is not valid, and Red indicates that GPS is not communicating with the LinkAlign antenna positioner. 4 Target Coordinates The target coordinates allows user entry of the target Latitude and Longitude position. This tool provides the user with a heading and distance to the desired target. 5 Bearing Angle Displays the calculated azimuth heading angle to the Target Coordinates. Once a target coordinate is entered the bearing angle will populate a heading. 6 Ground Distance Displays the line of sight ground distance between the current coordinates and target coordinates entered in the GPS window. Once a target coordinate is entered the ground distance will display the calculated distance between the two coordinates. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 17

18 Settings Page This section details the settings page. The settings page is a pop up window that is opened by selecting the gear button in the upper right side of the main control page (Identified below as callout number 1). The settings page (Identified below as callout number 2) allows user updates to the system. The full details of the settings page are provided below. 1 2 Callout number Callout Description 1 Settings Page button: Launches the settings window (callout number 2 above) 2 Settings window: Allows user input and provides status of current system settings. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 18

19 Callout Callout Callout Function number Description 1 Limits User configurable travel positioner travel limits. All entries are in degrees. Allows software adjustment to travel limits in Azimuth, Elevation, and optional Polarization axis. The default travel limits for each axis is maximum physical travel limit. The "save settings" button must be selected before updates are applied. 2 IP Settings User configurable IP address settings for the LinkAlign antenna positioner. Each LinkAlign positioner also has a non configurable IP address to access the system in case the primary IP address is lost or forgotten. See the IP Reset instructions for more information. The "save settings" button must be selected before updates are applied. 3 Users Allows users to be added or deleted. There must be at least one user to allow login to the system. The default user is "admin" with the password of "nextmove". The password may be changed or the entire user deleted. 4 Add New Allows new users to be added. 5 Serial Number Displays the LinkAlign antenna positioner serial number. This field is non configurable and is the unique identifier used by Nextmove to track warranty and software LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 19

20 revisions. 6 Reboot Forces the on board CPU to reboot. 7 NMT debugging info checkbox This is normally for factory use only. A Nextmove phone support engineer may ask you to check this box to display real-time analog and digital values used to control and monitor the system. 8 Firmware Display's the current software revision running on the Version LinkAlign digital controller. 9 "Choose File" Allows the user to browse for a file to upload new button software to the LinkAlign antenna positioner. 10 "Upload" button The upload button will load the file selected by the user. 11 "Set Pol Zero" button 12 "Clear Pol Zero" button 13 "Use Google" check box The "Set Pol Zero" button will identify the polarization current position as its zero position. Depending on the pol rotators current position, this may limit the travel in one direction and increase in the opposite. For example, if the "set pol zero was selected at 200 degrees the pol rotator would now have 20 degrees of clockwise direction and 420 degrees of counter clockwise direction. The "save settings" button must be selected before updates are applied. The "Clear Pol Zero" button will restore the factory zero location at the center of physical travel (±220º). The "save settings" button must be selected before updates are applied. Check box to allow the user interface to populate the topographical map in the map window. If left unchecked the map will not load but still display both ends of the link in the map area window. The "save settings" button must be selected before updates are applied. 14 LinkAlign System status Displays last action details for user review during configuration changes. 15 "Exit" button The "Exit" button will close the settings window and return to the main control page. 16 "Save Settings" button The "Save settings" button will save any updates made to the user configurable settings in the settings window. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 20

21 Updating Firmware Nextmove may make firmware updates available to customers. New firmware is loaded in the settings window under Firmware. Step 1, Select the "Choose File" button. Navigate your hard drive to locate the bin file provided by Nextmove. Once selected the file will show up to the right of the "Choose File" button. If no file has been selected, the text "No file chosen" will appear instead. Choose File Step 2, Press the "Upload" button located below the "Choose File" button. The software will then upload. Your browser will show upload progress in the lower left hand corner of the browser window. Upload Step 3, A message in green will appear "Firmware Uploaded Successfully!" Press the "Install" button indentified below to install the new firmware. Install Step 4, Reboot the LinkAlign by removing power to the positioner. This can be done by disconnecting either side of the PoE cable connected to the positioner. Step 5, Apply power and reload the web page. Return to the settings page and verify that the new firmware version matches the new release. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 21

22 IP Reset instructions The LinkAlign antenna positioner has a permanent IP address that is always accessible with the proper setup of your computers IP address settings. This IP address can be used to access the system and recall the current IP address settings or make other changes. It is important to follow the instructions below carefully as this IP reset address is not recognized by standard routers or switches. Step 1, Go to your computers TCP/IPv4 adapter settings and re-configure your computers IP network settings. You must use the specific IP address and subnet mask identified below. The positioner is setup to look for this specific routing and will not communicate if other IP addresses are used. Set a static IP address of: Set a subnet mask of: Select Ok to accept new settings Step 2, Connect the LinkAlign antenna positioner directly to the laptop or computer that has been reconfigured as shown below. The positioner should not have any routers or switches in line as most routers or switches do not recognize a 169 network and will not forward requests or status associated with this number range. 48VDC Power Configuration setup for IP Reset LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 22

23 Step 3, Using any web browser type the IP address into the web browser command line as shown below. The standard web browser control window for the LinkAlign antenna positioner will launch. The settings window can now be accessed to view the current IP settings for the unit or entry of new IP address can be made and saved to allow operation on your network. LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 23

LinkAlign-360FER Set-up and Operation Manual

LinkAlign-360FER Set-up and Operation Manual LinkAlign-360FER Set-up and Operation Manual Proprietary, Nextmove Technologies Page 1 Proprietary, Nextmove Technologies Page 2 Table of Contents General Notes:... 4 Description of items included with

More information

Products overview. Auto Point Antenna Alignment Solutions

Products overview. Auto Point Antenna Alignment Solutions Products overview Auto Point Antenna Alignment Solutions About Nextmove Design house and Manufacturer of auto antenna alignment products serving: Commercial communications Emergency Management Military

More information

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW2400iTR Indoor Wireless Ethernet

More information

Connecting the Radio:

Connecting the Radio: Connecting the Radio: Step 1: Connect the Cat5 cable from the radio into the RJ-45 jack marked CPE on the POE injector. The POE injector is not weather proof and should be installed indoors. Step 2: Connect

More information

AW58300HTA AW58300HTS USER S MANUAL

AW58300HTA AW58300HTS USER S MANUAL AW58300HTA AW58300HTS USER S MANUAL 5.8 GHz Outdoor 300 Mbps Wireless Ethernet Access Point and Subscriber Unit Radios Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S The

More information

AW5802xTP. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Panel. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

AW5802xTP. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Panel. AvaLAN. Industrial-grade, long-range wireless Ethernet systems 5.8 GHz Outdoor Wireless Ethernet Panel Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW5802xTP 5.8 GHz Outdoor Wireless Ethernet Panel.

More information

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

3 GHz Carrier Backhaul Radio. Model: AF-3X.   Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA LINK GPS MGMT DATA DATA MGMT GPS LINK 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA DATA MGMT GPS LINK Introduction Thank you

More information

AvaLAN AW58103HTS MANUAL ADDENDUM. 5.8 GHz Outdoor 100 Wireless 3-Port Ethernet Subscriber Unit Radio

AvaLAN AW58103HTS MANUAL ADDENDUM. 5.8 GHz Outdoor 100 Wireless 3-Port Ethernet Subscriber Unit Radio AW58103HTS MANUAL ADDENDUM 5.8 GHz Outdoor 100 Wireless 3-Port Ethernet Subscriber Unit Radio Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S AW58103HTS Addendum The AW58103HTS

More information

LINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK

LINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK LINK GPS MGMT DATA DATA MGMT GPS LINK 4 GHz Licensed Backhaul Radio Model: AF-4X 4 GHz Licensed Backhaul Radio Model: AF-4X LINK GPS MGMT DATA DATA MGMT GPS LINK Introduction Thank you for purchasing the

More information

Antenna Pointing Guide

Antenna Pointing Guide Antenna Pointing Guide 1039429-0001 Revision B September 10, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems, LLC All

More information

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide XLR PRO Radio Frequency (RF) Modem Getting Started Guide XLR PRO Radio Frequency (RF) Modem Getting Started Guide 90002203 Revision Date Description A September 2014 Initial release. B March 2014 Updated

More information

11 GHz FDD Licensed Backhaul Radio. Model: AF 11FX

11 GHz FDD Licensed Backhaul Radio. Model: AF 11FX 11 GHz FDD Licensed Backhaul Radio Model: AF 11FX 11 GHz FDD Licensed Backhaul Radio Model: AF 11FX Introduction Thank you for purchasing the Ubiquiti Networks airfiber AF 11FX. This Quick Start Guide

More information

GPSR400 Quick Start Guide

GPSR400 Quick Start Guide GPSR400 Quick Start Guide Rev. 6 Introduction Microlab s digital GPS repeater system can be used for cellular communications UTC synchronization for locations where the GPS signals are not readily available.

More information

AW5802xTR. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Radio. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

AW5802xTR. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Radio. AvaLAN. Industrial-grade, long-range wireless Ethernet systems AW5802xTR 5.8 GHz Outdoor Wireless Ethernet Radio Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW5802xTR 5.8 GHz Outdoor Wireless Ethernet

More information

BRU-100 Physical Installation

BRU-100 Physical Installation APPENDIX B BRU-100 In This Appendix: Warnings and Cautions, page 50, page 51 Check List, page 57 This appendix provides guidance for the physical installation of the BRU-100 Remote Unit at a subscriber

More information

GPSR116 Quick Start Guide

GPSR116 Quick Start Guide GPSR116 Quick Start Guide .21 [ 5,3] [482,6] 18.12 [460,3] GPSR116 Quick Start Guide Rev 2.35 [8,9] Introduction Microlab s digital GPS repeater system can be used for cellular communications UTC synchronization

More information

AW900xTR USER S MANUAL 900 MHz Outdoor Wireless Ethernet Radio

AW900xTR USER S MANUAL 900 MHz Outdoor Wireless Ethernet Radio USER S MANUAL 900 MHz Outdoor Wireless Ethernet Radio Industrial-grade, long-range wireless Ethernet systems Thank you for your purchase of the AW900xTR Outdoor Wireless Ethernet Radio. The AW900xTR includes:

More information

AW5800-SPEC USER S MANUAL

AW5800-SPEC USER S MANUAL USER S MANUAL 5.8 GHz Site Survey Spectrum Analyzer Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S User s Manual Thank you for your purchase of the AW5800-SPEC Site Survey

More information

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit TT-208 300Mps 5.8 GHz IP Camera Wireless Transmission Kit User s Manual V1.0 02 / 2014 Welcome Thank you for purchasing the TT-208 Wireless Transmission Kit for IP Cameras. This user s manual is designed

More information

AW900-SPEC USER S MANUAL

AW900-SPEC USER S MANUAL USER S MANUAL 900 MHz Site Survey Spectrum Analyzer Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S User s Manual Thank you for your purchase of the AW900-SPEC Site Survey

More information

Mounting and Alignment Overview

Mounting and Alignment Overview CHAPTER 3 This chapter provides an overview of bridge mounting and antenna alignment. The following sections are included in this chapter: Mounting the Bridge, page 3-2 Mounting Hardware, page 3-2 Bridge

More information

UCP-Config Program Version: 3.28 HG A

UCP-Config Program Version: 3.28 HG A Program Description HG 76342-A UCP-Config Program Version: 3.28 HG 76342-A English, Revision 01 Dev. by: C.M. Date: 28.01.2014 Author(s): RAD Götting KG, Celler Str. 5, D-31275 Lehrte - Röddensen (Germany),

More information

AW900F AW900F-PAIR USER S MANUAL

AW900F AW900F-PAIR USER S MANUAL AW900F AW900F-PAIR USER S MANUAL 900 MHz Industrial Wireless Ethernet Radios Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW900F Indoor

More information

M-0418 REV:0

M-0418 REV:0 1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that

More information

Ground System Training Department

Ground System Training Department Module 7: IPSTAR Uplink Access Test (IUAT) Ground System Training Department 2012-03-Standard (iuat1.14)-uti-101 THAICOM Public Company Limited Module Objectives At the end of the module the participant

More information

QDV120 Operation and Pointing manual

QDV120 Operation and Pointing manual QDV120 Operation and Pointing manual MPAD1 Plus OP-080316-E1 page 1 Contents Item Description Page 1.0 Health and Safety for Operators and Installation Staff 3 2.0 Transit case Reflector/Mount/BUC/LNB

More information

Installation Guide. Hiltron Motorized Antenna Mount HMAM

Installation Guide. Hiltron Motorized Antenna Mount HMAM HMAM_Install_A.doc Page 1 of 20 Installation Guide for Hiltron Motorized Antenna Mount HMAM HMAM_Install_A.doc Page 2 of 20 Table of Contents 1 Overview...3 2 Unpacking and Inspection...3 3 Contents of

More information

Revision Date: 6/6/2013. Quick Start Guide

Revision Date: 6/6/2013. Quick Start Guide Revision Date: 6/6/2013 Quick Start Guide Important Notice Copyright 2013Frontline Test Equipment. All rights reserved. i Important Notice Table of Contents Purpose 1 Minimum Hardware Requirements 1 Internet

More information

AC and DC solutions- Multiple AC and DC solutions available, please contact factory for your application.

AC and DC solutions- Multiple AC and DC solutions available, please contact factory for your application. The ATX-3000 antenna tracking controller is a user-friendly microprocessor-based intelligent positioning system to reliably track inclined orbit satellites or for use as a positioner for geosynchronous

More information

USER S MANUAL ADDENDUM Matched Pair Bridges

USER S MANUAL ADDENDUM Matched Pair Bridges USER S MANUAL ADDENDUM Matched Pair Bridges Certain AvaLAN radios are sold as matched pairs, pre-configured as a wireless Ethernet bridge. The manual supplied with the pair does not include information

More information

MPR kHz Reader

MPR kHz Reader MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied

More information

Featherweight GPS Tracker User s Manual June 16, 2017

Featherweight GPS Tracker User s Manual June 16, 2017 Featherweight GPS Tracker User s Manual June 16, 2017 Hardware Configuration and Installation The dimensions for the board are provided below, in inches. Note that with the antenna installed, the total

More information

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS 2016 15 Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS Right Side Worms FRONT REMOTE CONTROL BACK Left Side Worms Channel Display Up Stop Down Channel

More information

AES 7705i MultiNet Receiver System Initial Installation and Setup Guide

AES 7705i MultiNet Receiver System Initial Installation and Setup Guide AES 7705i MultiNet Receiver System Initial Installation and Setup Guide AES Corporation 285 Newbury Street. Peabody, Massachusetts 01960-1315 USA Tel: USA (978) 535-7310. Fax: USA (978) 535-7313 Copyright

More information

Rosemount 753R Remote Web Based Monitoring Indicator

Rosemount 753R Remote Web Based Monitoring Indicator Rosemount 753R Remote Web Based Monitoring Indicator Product Discontinued February 2010 Start Overview Rosemount 753R with Integral 3051S Pressure Transmitter Rosemount 753R with Remote Mounted HART Transmitter

More information

Toughsat. Users Manual

Toughsat. Users Manual Toughsat Users Manual TOUGHSAT USERS MANUAL v.2.1 February 2012 Important warning regarding your Toughsat System ALL POWER to ALL system electronics MUST be disconnected if connecting the control cable

More information

Quick Start Guide. Version: 1.0 F/W: V1.2.0_RC1b. Date: December 11, 2017

Quick Start Guide. Version: 1.0 F/W: V1.2.0_RC1b. Date: December 11, 2017 VigorAP 920R Series Ruggedized Outdoor AP with Extreme 802.11ac Power Warranty Quick Start Guide Version: 1.0 F/W: V1.2.0_RC1b Date: December 11, 2017 We warrant to the original end user (purchaser) that

More information

IG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002

IG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002 IG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002 CONVENTIONS USED IN THIS GUIDE These safety alert symbols are used to alert about hazards or hazardous situations that can result in

More information

C-COM Satellite Systems Inc. Page 1 of 39

C-COM Satellite Systems Inc. Page 1 of 39 Page 1 of 39 inetvu Fly-75V & Fly-98G/H/V & Fly-981 User Manual The inetvu brand and logo are registered trademarks of C-COM Satellite Systems, Inc. Copyright 2006 C-COM Satellite Systems, Inc. 1-877-iNetVu6

More information

WEB I/O. Wireless On/Off Control USER MANUAL

WEB I/O. Wireless On/Off Control USER MANUAL Wireless On/Off Control Technical Support: Email: support@encomwireless.com Toll Free: 1 800 617 3487 Worldwide: (403) 230 1122 Fax: (403) 276 9575 Web: www.encomwireless.com Warnings and Precautions Warnings

More information

MESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX

MESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX MESA-HPX Assembly and Installation Manual w/appendix A for Prodelin Antenna 901-Manual-MESA-HPX Rev 30 March 2011 2 INDEX Installation Cautions 4 Installation Pole Height Orientation of the Mount on the

More information

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer AA-35 ZOOM Antenna and cable analyzer RigExpert User s manual . Table of contents Introduction Operating the AA-35 ZOOM First time use Main menu Multifunctional keys Connecting to your antenna SWR chart

More information

HT1000 Satellite Modem Installation Guide

HT1000 Satellite Modem Installation Guide HT1000 Satellite Modem Installation Guide 1039110-0001 Revision A October 17, 2012 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2012 Hughes Network

More information

Underwater GPS User Manual

Underwater GPS User Manual Underwater GPS Document number W-DN-17002-3 Project Classification - Rev Prepared by Checked by Approved by Short description 1 2017-08-03 T. Trøite O. Skisland T. Trøite Initial 2 2017-08-04 T. Trøite

More information

Installation Guide. Suitable for: OEM Integration OEM Installation Retro Fit Installation

Installation Guide. Suitable for: OEM Integration OEM Installation Retro Fit Installation Installation Guide Suitable for: OEM Integration OEM Installation Retro Fit Installation DTI AngleBlaster release 1.1 DTI 2010 Overview Angleblaster Installation Guide A-1 To obtain the best accuracy from

More information

HandPunch Installation Guide

HandPunch Installation Guide HandPunch Installation Guide www.centraltimeclock.com HandPunch 3000/4000 Manual Planning an Installation Site Preparation Before you begin installation, check the site blueprints, riser diagrams, and

More information

Instruction Manual. Quick Setup

Instruction Manual. Quick Setup Instruction Manual Quick Setup Make sure the Carryout G2 antenna is in a location with a clear view of the southern sky. Connect the provided coaxial cable from the primary receiver to the MAIN port on

More information

Antenna Control Unit (ACU) Graphical User Interface (GUI) Software Instruction Manual

Antenna Control Unit (ACU) Graphical User Interface (GUI) Software Instruction Manual ISO 9001:2015 Certified Antenna Control Unit (ACU) Graphical User Interface (GUI) Software Instruction Manual Quasonix, Inc. 6025 Schumacher Park Dr. West Chester, OH 45069 19 July 2018 Revision 1.5 Software

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title Appendices 1 (10) Project designation R5 RIC Document title CONTENTS 1 Installation... 2 1.1 Connectors... 2 1.1.1 Power... 2 1.1.2 Video... 2 1.1.3 Sync... 3 1.1.4 RS232/ARP/ACP... 3 1.1.5 Radar data...

More information

Quick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface

Quick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface INTEROPERABILITY NOW Quick Start Guide RSP-Z2 Dual Channel Analog-IP Interface Designed and Manufactured by: JPS Interoperability Solutions 5800 Departure Drive Raleigh, NC 27616 919-790-1011 Email: sales@jpsinterop.com

More information

Quick Start Instructions EMV-INspektor V2

Quick Start Instructions EMV-INspektor V2 Connecting the : The illustration below shows the connection diagram for the. Step 1: Before connecting the to the voltage supply, first establish the connection of the to the measuring clamp adapters.

More information

High Security Supplement

High Security Supplement High Security Supplement User Manual Supplement foravalan Wireless Radios with FIPS 140-2 Security AW900FS USER S MANUAL Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S High

More information

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1 ULC Version 7.X August 2015 USER MANUAL pg. 1 Overview Universal LED Controller () provides independent true constant-current or voltage control of two LED loads from 0.02 to 4 Amps continuous (DC) with

More information

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1 ULC Version 6.2 June 12, 2013 USER MANUAL pg. 1 Overview Universal LED Controller () provides independent true constant-current or voltage control of two LED loads from 0.02 to 4 Amps continuous (DC) with

More information

WPE 48N USER MANUAL Version1.1

WPE 48N USER MANUAL Version1.1 Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.

More information

Thuraya Orion IP Satellite Terminal. Maritime Installation Guide

Thuraya Orion IP Satellite Terminal. Maritime Installation Guide Thuraya Orion IP Satellite Terminal Maritime Installation Guide 3500867-0001 Revision 2 November 27, 2013 Copyright 2013 Hughes Network Systems, LLC All rights reserved. This publication and its contents

More information

Fireye. NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Fireye. NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION SAFETY INFORMATION. FX04-1 Shown NEX-3004 JUNE 27, 2011 FX04-1 Shown Fireye NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION This bulletin describes the installation and operating instructions for the FX04 and FX04-1, 3 lb.-ft./

More information

Installation Instructions

Installation Instructions Installation Instructions For 0.2m Ultra-high Performance Antenna Model ADxxG-0-T2 Before Installation, please read these instructions carefully. This instruction guide is for the installation of 8 inch

More information

GNSS Conductor GF. User s Guide. (Document No. SE )

GNSS Conductor GF. User s Guide. (Document No. SE ) GNSS Conductor GF User s Guide (Document No. ) www.furuno.com IMPORTANT NOTICE No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying

More information

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide M-5578/0516 M-5578/0516 Section TABLE OF CONTENTS 1 Introduction... 1 2 Quick Guide on Getting Started... 2 Mounting the LVTX-10 Series

More information

USER MANUAL VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT

USER MANUAL VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT BridgeNet International Contents 1 Welcome... 2 1.1 Accessibility... 2 1.2 Navigation... 2 1.3 Interface Discovery... 4 2 Menu Bar... 5 2.1 Show Flights...

More information

Installation Instructions

Installation Instructions Installation Instructions For 4 foot / 1.2m Diameter Ultra-high Performance Antenna Model ADxxG-4-T2 Before Installation, please read the instructions carefully. This instruction guide covers the installation

More information

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements.

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements. User Manual (of Spike ios version 1.14.6 and Android version 1.7.2) This User Manual will guide you through the steps to set up your Spike and take measurements. 1 Mounting Your Spike 5 2 Installing the

More information

Black Marlin radar systems may be purchased with a flat-top radome for mounting cameras on

Black Marlin radar systems may be purchased with a flat-top radome for mounting cameras on SPECIFICATIONS The Black Marlin is DMT s midrange security radar system. It may be used to search and track threats from land and sea. This radar is an X- Band, pulsed- Doppler system that operates in

More information

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers The Indelac / AC Motor Controllers are used for proportional positioning of split phase AC actuator motors. An external command signal of 0-0V, -V, or -0mA can be used to compare to a feedback signal from

More information

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LincView OPC Enhanced Diagnostics Utility It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information

Installing the Hughes BGAN Remote Antenna

Installing the Hughes BGAN Remote Antenna Installing the Hughes BGAN Remote Antenna Product description BGAN Remote Antenna The Hughes BGAN Remote Antenna (HNS Part No. 9501286-0001) is designed to be permanently installed with the Basic Fixed

More information

NTS-pico. Miniature NTP Time Server for Small Networks

NTS-pico. Miniature NTP Time Server for Small Networks NTS-pico Miniature NTP Time Server for Small Networks Table of Contents Introduction... 3 Safety instructions... 3 What is NTS-pico?... 3 Installation... 4 Hardware... 4 General presentation... 4 Antenna

More information

RC3000/ RC3050 INTERFACE SPECIFICATIONS

RC3000/ RC3050 INTERFACE SPECIFICATIONS RC3000/ RC3050 INTERFACE SPECIFICATIONS Research Concepts, Inc.; Lenexa, KS 66215; PH: (913)469-4125; FAX: (913)469-4168 WWW.RESEARCHCONCEPTS.COM SUPPORT@RESEARCHCONCEPTS.COM Overview The RC3000 Satellite

More information

Sales & Technical Support: &

Sales & Technical Support: & Sales & Technical Support: sales@tersus-gnss.com & support@tersus-gnss.com Table of Content Table of Content...1 List of Figures...3 List of Tables... 4 Revision History... 5 1. Introduction...6 1.1 Overview...6

More information

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna Release 3.0 NN47251-311 Issue 02.01 June 2014 Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna How to get help To access the complete range of services and

More information

Produced by Mr B Ward (Head of Geography PGHS)

Produced by Mr B Ward (Head of Geography PGHS) Getting to Know Google Earth The following diagram describes some of the features available in the main window of Google Earth. 9. Sun - Click this to display sunlight across the landscape. 1. Search panel

More information

Camera. Multi Lens Camera A-427-V. Quick Start Guide

Camera. Multi Lens Camera A-427-V. Quick Start Guide Camera Multi Lens Camera A-427-V Quick Start Guide 0 About this Manual Multi Lens Camera Quick Start Guide This Manual is applicable to A-427-V Network Camera. The Manual includes instructions for using

More information

DPC-10. DPC-10 Software Operating Manual. Table of Contents. Section 1. Section 2. Section 3. Section 4. Section 5

DPC-10. DPC-10 Software Operating Manual. Table of Contents. Section 1. Section 2. Section 3. Section 4. Section 5 Table of Contents Section 1 Section 2 Section 3 Section 4 Section 5 About the Software Test Function Programming Functions Connections Basic Mode Connection RC Mode Connection Using the DPC-10 Test Functions

More information

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints

More information

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections...

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections... DPC-11 Operation Manual Table of Contents Section 1 Introduction...2 Section 2 Installation...4 Software Installation...4 Driver Installastion...7 Section 3 Operation...9 D Series Servo Programming...9

More information

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport.

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport. NTS-4000-S Installation and Configuration Manual CONTENTS Contents... 2 Introduction... 4 Features... 4 What should be shipped... 5 Standard Parts... 5 Optional Parts... 5 Technical Specification... 6

More information

USER MANUAL VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT

USER MANUAL VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT VOLANS PUBLIC DISPLAY FOR JOHN WAYNE AIRPORT BridgeNet International Contents 1 Welcome... 2 1.1 Accessibility... 2 1.2 Navigation... 2 1.3 Map Display... 4 2 Menu Bar... 5 2.1 Show Flights... 5 2.2 Adjust

More information

Satellite Terminal. Installation Guide. Release 2.2 Ref. nr

Satellite Terminal. Installation Guide. Release 2.2 Ref. nr Satellite Terminal Installation Guide Release 2.2 Ref. nr. 37628 Table of Contents Table of Contents Table of Contents... 2 1 Introduction... 3 1.1 About this Guide... 3 1.2 Material Provided in the Box...

More information

RM600 Carrier Grade E1 Radios

RM600 Carrier Grade E1 Radios Carrier Grade E1 Radios Quick Start Guide Package Contents ODU 1 IDU 1 Mast/Wall Mounting Kit 1 Outdoor Ethernet Cable (Optional) 1 External Antenna (Optional) 1 Power Supply Cable 1 Quick Start Guide

More information

Quick Start Guide. P-TEC Gotthard

Quick Start Guide. P-TEC Gotthard Quick Start Guide P-TEC Gotthard Important Notice This product has been designed and manufactured so that it does not represent a personal safety hazard for the user. Any misuse can lead to electric shock

More information

Quick Start Guide. Contents

Quick Start Guide. Contents 1 Quick Start Guide Contents Powering on the Machine Login/Password Entry Jaw Set Up High Security Cut by Code High Security Jaw Set Up Edge Cut Cut by Code Edge Cut Cut by Decode Cutter Replacement Tracer

More information

Software User Manual

Software User Manual Software User Manual ElectroCraft CompletePower Plus Universal Servo Drive ElectroCraft Document Number: 198-0000021 2 Marin Way, Suite 3 Stratham, NH 03885-2578 www.electrocraft.com ElectroCraft 2018

More information

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1 Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11

More information

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE 8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...

More information

SMACSM Frequency Agile Pilot Carrier Redundancy Source

SMACSM Frequency Agile Pilot Carrier Redundancy Source SM by Status Monitoring And Control Solutions (HMS Compliant, SNMP Based) SMACSM Frequency Agile Pilot Carrier Redundancy Source INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

BLACK MARLIN Specification SPECIFICATIONS. Black Marlin radar systems may be purchased with a flattop radome for mounting

BLACK MARLIN Specification SPECIFICATIONS. Black Marlin radar systems may be purchased with a flattop radome for mounting Black Marlin radar systems may be purchased with a flattop radome for mounting cameras on top. This gives 360 degrees of coverage for both the radar and camera. SPECIFICATIONS The Black Marlin is DMT s

More information

Instruction Manual REMOTE CONTROL BOX OM3500 A. OM POWER, s. r. o Báč 126 SLOVAKIA

Instruction Manual REMOTE CONTROL BOX OM3500 A. OM POWER, s. r. o Báč 126 SLOVAKIA Instruction Manual REMOTE CONTROL BOX OM3500 A OM POWER, s. r. o. 930 30 Báč 126 SLOVAKIA General description of the OM 3500 A Remote control Remote Control expands possibilities of using OM3500 A up to

More information

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt. Quick Start Guide Backplate Backup Key Battery Cover Touchscreen Assembly Parts Strike Bolt Inside Assembly Thumbturn Reinforcement Plate Set Screw Reinforcement Screws Inside Assembly Screw Backplate

More information

Print Head Installation Guide

Print Head Installation Guide Print Head Installation Guide MCS Raptor 6 (MCS Eagle AMS Software) is copyright of MCS Incorporated. 2015 MCS Incorporated. 1 Contents Tools... 4 Warnings... 4 Introduction... 4 Section One - Pillar Installation...

More information

User Manual. Last updated on September 5, 2008

User Manual. Last updated on September 5, 2008 User Manual AlfaSpid by Hy-Gain For use with: AlfaSpid Rotator RAS1 & Controller Rot2Prog by Hy-Gain Azimuth and Elevation rotator and controller AZ/EL RAS1 OR Elevation rotator and controller EL REAL1

More information

75cm ODU/SurfBeam 2 Point and Peak Job Aid

75cm ODU/SurfBeam 2 Point and Peak Job Aid Summary This Job Aid covers: 75cm ODU/SurfBeam 2 Point and Peak Job Aid Preparing the Antenna for Pointing and Peaking Configure the SurfBeam 2 Modem and 75cm TRIA Point Elevation Set the Skew Point Azimuth

More information

Endurance R/C Wi-Fi Servo Controller 2 Instructions

Endurance R/C Wi-Fi Servo Controller 2 Instructions Endurance R/C Wi-Fi Servo Controller 2 Instructions The Endurance R/C Wi-Fi Servo Controller 2 allows you to control up to eight hobby servos, R/C relays, light controllers and more, across the internet

More information

The second case is labeled as the Senor Node Kit. It contains four individual Sensor Nodes, attachment plates, and batteries for the Sensor Nodes.

The second case is labeled as the Senor Node Kit. It contains four individual Sensor Nodes, attachment plates, and batteries for the Sensor Nodes. PROPRIETARY ETREMA e488:sg1.1:production:usermanual:introduction http://astro/precious/e488/sg1.1/production/usermanual/introduction 1 of 2 5/30/2012 1:31 PM This user manual is for the STARS system which

More information

Installing the 3 Indexer: PRS Standard Tools

Installing the 3 Indexer: PRS Standard Tools 888-680-4466 ShopBotTools.com Installing the 3 Indexer: PRS Standard Tools Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Route Cable into Box...5

More information

RC2000. Cable Preparation ACU Installation Troubleshooting/Alarm codes. Patriot 1.8m

RC2000. Cable Preparation ACU Installation Troubleshooting/Alarm codes. Patriot 1.8m RC2000 Cable Preparation ACU Installation Troubleshooting/Alarm codes Patriot 1.8m Installation Instructions I. Needed equipment: Multimeter, small flathead screwdriver, large phillips screwdriver,

More information

ORCA RX-103 IS A OVERBOARD RECOVERY COMMUNICATIONS APPARATUS RECEIVER. ORCA RX-103 Owner s Manual

ORCA RX-103 IS A OVERBOARD RECOVERY COMMUNICATIONS APPARATUS RECEIVER. ORCA RX-103 Owner s Manual ORCA RX-103 IS A OVERBOARD RECOVERY COMMUNICATIONS APPARATUS RECEIVER ORCA RX-103 Owner s Manual BriarTek, Inc. Technical Support: 703.548.7892 Email: support@briartek.com Web: www.briartek.com 2 Introduction

More information

NEXEDGE Type-D Trunking System

NEXEDGE Type-D Trunking System NEXEDGE Type-D Trunking System 2015.26.05 Copyright 2014 JVCKENWOOD Corporation. All rights reserved. 1. Type-D Trunking Overview 1. Type-D Trunking System Overview NEXEDGE Type-D Trunking System New affordable

More information