1 User s Manual For DIGITAL PANEL METER QUASAR Class 1.0 LARSEN & TOUBRO LIMITED MYSORE WORKS Table of contents

2 Section 1. General Details 1 Section2. Front Panel Details 1 Section 3. Installation 9 Section 4. Mechanical Dimensions 10 Section 5. Specific Points 10 Section 6. Programming philosophy 11 Section 7. Warranty & Disclaimer 12 Page No. Appendix 1. Technical Specifications 14 Appendix 2. Modbus Details 16 Appendix 3. Memory Map 27 Appendix 4. Meter Programming Procedure 34 Appendix 5. Display Screens 40 Appendix 6. Wiring Diagram 44 Appendix 7. Dimensional Details 48

3 General: QUASAR is a 96 x 96 mm, flush mounted, multi screen digital panel meter for measuring electrical parameters. The meter is designed with DSP technology to combine measurements of both instantaneous and cumulative valeus in an electrical feeder. The device is built with a custom made, backlit, LCD display to provide high resolution view of various parameters to the viewer. The parameters are displayed over 21 screens which can be scrolled up & down by front panel push buttons. The feeder parameters like CT / PT ratings, baud rates, port address, demand parameters etc. are set by additional push buttons (PBs) on the front panel. 2.0 Front Panel : Please see fig. 1. The front panel has one LCD display, 4 PBs and a LED. The functions of the PBs are explained in the sections 2.3, 2.7 and Appendix 4. The LED flashes at a rate proportional to the kwh in the feeder. 2.1 Display Features : QUASAR comes with a custom made LCD display. The power parameters are displayed through 21 screens. Please refer Appendix 5 for details of parameters displayed in each screen. Please alos refer to Table-1 for a ready reckoner of screen references. The following displays appear immediately after power on- 1. all segments check 2. serial no. 3. version no. Finally it continuously displays the selected power on screen until keys are pressed. 2

4 -2- Fig Front panel push buttons : There are four Push buttons (PBs) as on the front panel to do following functions: a) scrolling thro display b) min/max/present values selection c) reset of min/max values d) front panel programming. 3

5 -3- Parameter Unit P1 P2 P3 (4w only) Voltage (P-N for 4W or P-P for 3W) Tot/ Avg Table-1 Max/min option V 2, 16 2, 17 2, 18 1 Current A 3, 19 3, 20 3, 21 1 Active power kw , 1 (only for total) Reactive power L kvar L (Lo r C) (only for total) Reactive power C kvar C (Lo r C) (only for total) Apparent power kva (only for total) Power factor PF Phase angle Φ- V (w.r.t. voltages) Phase angle (between Φ- A voltages & currents) Frequency Hz 12 * * 11 Power demand (max.) Pd 11 Active energy kwh 12 Reactive energy L kvarlh 13 Reactive energy C kvarch 14 Apparent energy KVAh 15 Voltage Fundamental ~ Voltage Distortion ~D Current Fundamental ~ Current Distortion ~D

6 -4- Notes: 21 display screens of 3 parameters each are available. (nos. in the above table 1 indicate the order of the default display screens). Note: * in above table indicates that Freq. of phase 1 is displayed if phase1 is available, freq. of phase 2 is displayed if phase1 is not available and phase 2 is available, freq. of phase 3 is displayed if phase1&2 are not available and phase 3 is available. The power up screen will be by default- total power (of all phases), average voltages (of all phases) & average currents (of all phases). The default power ON screen is programmable. It will remain in this display until keys are pressed as explained below. 2.3 Functions of front panel push buttons : Display scroll PBs 5 & 6. The display scroll PBs are indicated as 5 & 6. The21 screens of display can be viewed one after the other by pressing 5 or 6 PBs of front panel. Pressing 5 & 6 keys simultaneously will take display to auto scroll mode. The display will scroll through all screens at a fixed rate of 3 secs. In auto scroll mode, pressing 5 or 6 key will take display to manual mode. (No time out for any mode of display). 5

7 -5- Max / min values selector PB MODE QUASAR stores max/min values of the feeder (only for parameters ticked in Table-1). The PB designated as MODE is meant to read these max/min values. Normally latest updated values will be displayed. By pressing the push button MODE, the display can be switched to Min., Max. or present values one after the other. The display will remain in MIN & MAX modes until the PB is pressed again. In case there is a maximum timeout of 2 mins., the display will go back to Present values. Min/Max modes are not supported in auto scroll mode. Reset Push button Resets the max/min values, except power demand & energies. 2.4 Energy & Pulse outputs : Units and precision of energy will vary with the CT*PT ratios selected as shown in table below. CT*PT Display format Unit < 10 xxxxxx.xx k < 100 xxxxxxx.x k <= 1000 Xxxxxxxxx k <10,000 xxxxxx.xx M <1,00,000 xxxxxxx.x M <10,00,000 Xxxxxxxx M 6

8 -6- PULSE OUTPUT: kwh pulse output LED is available. Pulses/kWh Voltage/current 2,500 / (external CT*PT ) 3ph 4W 415 V (L-L) / 5A 12,500 / (external CT*PT ) 3ph 4W 415 V (L-L) / 1A 10,000 / (external CT*PT ) 3ph 4W/3W 110 V (L-L) / 5A 50,000 / (external CT*PT ) 3ph 4W/3W 110 V (L-L) / 1A 2.5 Resetting (clearing) the stored parameters Pressing reset key on front panel clears off all the max./min. values except the following parameters. a) Power demand max. value can be cleared only in the programming mode. b) Energy counters can be cleared only in programming mode. 2.6 Harmonics for Voltage & Current Phase wise voltages/currents are separately available as - total fundamental (~) distortion (D) where distortion = square root (total 2 -fundamental 2 ) 7

9 2.7 Set up & Configuration -7- Set up configuration is possible through front panel keys or RS485 port (optional). Viewing and modifying of setup through front panel. is possible all the time (not only on power on) and is password protected. Programming mode can be entered from front panel by pressing simultaneously 5 and MODE keys. Meter restarts after coming out of programming mode. Refer appendix 4 for details of programming through front panel. Refer appendix 3 for details of programming through RS485. Following are the setup (programming) options - a) CT primary/secondary Change in CT ratio will automatically change the resolution of the parameters displayed. Primary and secondary values can be selected between 1 to Default on initialization: 1 b) PT primary/secondary Change in PT ratio will automatically change the resolution of the parameters displayed. Primary and secondary values can be selected between 1 to Default on initialization: 1 c) Clear - clear energy counters - clear max./min. demand 8

10 -8- d) Power demand - Parameter kw or kva - Integration period-1 to 60 mins.(not w.r.t RTC) Default on initialization: kw & 30mins. Any change in power demand settings, clears max./min. demand values. e) Default Power ON screen The default power ON screen can be selected as one of the 21 displays. Default on initialization: Total power, average voltage of all 3 phases & average current of all 3 phases. f) Slave ID setting (Available only for meter with RS485 option ) Unique slave IDs can be set for each meter for monitoring from a PC. Default on initialization: 1 g) Port properties settings (Available only for meter with RS485 option ) Baud rate- 300 bps to 9600 bps Parity- Even, odd, none Default on initialization: 4800 bps, even. h) Password setting (only for front panel programming) Default password is

11 RS485 COMMUNICATION (optional) With this option, the meters can be networked and various parameters can be monitored on a central PC. All parameters will be available via the RS 485 port. Set up configuration is also possible through this port. Protocol : MODBUS in RTU mode. Refer appendix 3 and appendix 2 for RS485 & MODBUS details. 3.0 Installation : 3.1 Incoming Inspection : Before the meter is installed, visual inspection for any damage due to transport, has to be done. If there are any damages, please refer the warranty sheet and take appropriate action. 3.2 Re-Packing : If the meter has to be returned to the supplier, the meter has to be repacked in its original packing. 3.2 Optimum Field conditions : For the reliability and better life of product, the unit has to be operated at moderate temperatures and humidity. The meter is designed to work from 5 to 60 degrees C and humidity of 95%RH non condensing. 3.3 Storage : In case of meter not installed after receipt, it has to be stored in a dry place in its original packing material. 10

12 Extra Precautions : Make sure that voltage, current ratings and the configuration of meter is as per the requirements. Wrong connection can severely damage the meter, which is not covered under warranty. 3.5 Wiring connections: Wiring of the meter has to be done as per wiring diagrams in appendix Mechanical dimensions: As per Appendix Mounting on the panel : The meter is supplied with clip on type mounting accessories. After inserting the meter into the designated cut out on the panel, the clip on clamps have to be fixed on the back side to hold the meter against the panel firmly. 5.0 Specific Points to note : QUASAR uses CT/PT inputs for measuring and display of electrical parameters. Following points should be noted : 5.1 Power demand calculation : Integration period starts and continues from power on, i.e. If integration period selected is 30mins. and if 20mins of integration period is completed and power fails, then in the next power ON, the power is accumulated for the next 10 mins and then demand is computed. 11

13 Current reversal conditions : a) Energies are updated as it is with the sign i.e. negative energies are subtracted & positive energies are added and stored in a single register (no forward & reverse). The negative reading is made positive by adding 10^8. b) Demand is calculated by algebraically adding the powers, but if final demand is negative then display shows just to indicate that something is wrong. 5.3 Unit of Voltage and current when kilo : Unit of voltage: for PT ratio <=30 unit is V for PT ratio >30 V blinks indicating unit is kilo Volt. Unit of current: for CT ratio <=75 unit is A for CT ratio >75 A blinks indicating unit is kilo Amp. 6.0 Programming the meter : Parameters like CT/PT ratios etc have to be programmed into the meter so that it can read the feeder data correctly. Please refer Appendix 4 for detatils of how to programme the meter. 12

14 7.0 Warranty : -12- Larsen & Toubro Limited warrants that all the L&T products will meet L&T's published product specifications, and will be free of defects in workmanship and materials for a period of 12 months from the date of invoice from L&T. L&T's obligation under this warranty shall be limited to servicing or replacing defective parts subject to the following terms and conditions provided the notice of defects and satisfactory proof thereof is given to L&T by its distributor or its customer within the Warranty period. 1. L&T s shall provide repairs and maintenance service for all equipment sold/or distributed by L&T, and products which cannot be repaired by L&T will be returned, subject to L&T's prior consent for free repairs. 2.Defective parts shall be serviced or replaced by L&T on one way freight paid basis. This warranty does not cover any defect in the product caused by accident, misuse, neglect, alteration modification or substitution of any of the components or parts, or any attempt at internal adjustment by unauthorized service personnel. 13

15 -13- Under no circumstance shall L&T be liable for any consequential or resulting injury or for loss, damage of expense directly or indirectly from the use of this product. The foregoing warranty is in lieu of all other warranties, expressed or implied, and is the sole and exclusive remedy for any claim arising from any defect in L&T products. Disclaimer Sufficient care is taken to provide all information regarding the product but L & T does not claim any responsibility for the damages caused by using the product directly or indirectly. 14

16 -14- Appendix 1: TECHNICAL SPECIFICATIONS: Accuracy For power Class IEC 1036/IS For Voltage 0.5% of readout ± 2 digits For Current 0.5% of readout ± 2 digits Voltage(Vn) 3Ph 4W- 415V AC (-40% to +20%) 110V AC (-40% to +20%) 3Ph 3W- 110V AC (-40% to +20%) Current (In) 5A or 1A (to 200%) Starting current 0.2%In (Class 1.0) Frequency 50 Hz +10% Load characteristics Short time over current < 8 VA in potential circuit < 0.5 VA in current circuit 40 times In for 500ms Electromagnetic compatibility IEC 1036/IS (Class 1.0) ESD 8 kv, EFT 2 kv 15

17 -15- Case material Insulation properties Display Plastic moulded Protected to IP51- IEC 1036/IS (Class 1.0) HV & insulation resistance IEC 1036/IS (Class 1.0) Backlit LCD, 10mm height digits Pulse output Pulses/kWh Voltage/current 2,500 / (external CT*PT ) 3ph 4W 415 V (L-L) / 5A 12,500 / (external CT*PT ) 3ph 4W 415 V (L-L) / 1A 10,000 / (external CT*PT ) 3ph 4W/3W 110 V (L-L) / 5A 50,000 / (external CT*PT ) 3ph 4W/3W 110 V (L-L) / 1A Temperature Humidity Dimension Weight c to 60 0 c for operation 20 0 c to 70 0 c for storage 95% RH non condensing 96 x 96 mm - depth 105 mm < 600gms 16

18 -16- Appendix 2: MODBUS DETAILS 1. DETAILS OF COMMUNICATION INTERFACE RS485 interface is available to communicate with the meter. The interface is available at the terminals. For connection details refer Apppendix Interface Standard: The configuration details to communicate with the meter are given below- Standard RS485 (half duplex) Baud rate Selectable- 9600, 4800, 2400,1200,600 or 300 bps Parity Selectable- None, odd or even Start bit 1 Stop bit Protocol: The RS485 interface uses MODBUS Protocol in RTU mode. Communicating with the meter involves sending commands to the meter for reading and writing the particular register. The meter can be addressed with specific user defined meter address (slave ID) from DETAILS OF MODBUS PROTOCOL In the explanation of protocol the examples used are specific to L&T meters. The details of the protocol are also limited to L&T meters. 17

19 Remote Terminal unit Framing: In RTU mode data is sent as 8-bit binary characters. In RTU mode, message characters must be transmitted in a continuous mode. The receiving device monitors the elapsed time between receipt of characters i.e. inter byte delay. If inter byte delay is three and one half the character time (for e.g. at 9600bps, the max. inter byte delay expected will be 1ms*3.5), the receiving device can timeout. The max. response time of the meter to a command, i.e. the time taken to send the first byte out in response to the command is max. 60ms. ADDRESS FUNCTION DATA CHECK 8 BITS 8 BITS N * 8 BITS 16 BITS 2.2 Address field: The meter can be addressed with specific user defined address from Each slave must be assigned a unique address and only the addressed slave responds to query that contains its address. When the slave sends a response the slave address informs the master which slave is communicating. In broadcast message, an address of 0(zero) is used. All slaves interpret this as an instruction to read and take action on the message, but do not issue a response message. 18

20 Function field: The function code field tells the addressed slave what function is to be performed. The higher order bit in this field is set by the slave device to indicate that other than a normal response is being transmitted to the master device (See SECTION 3 for exception response). The following functions have been implemented in the meter. CODE MEANING ACTION 03 Read holding registers Obtains current binary value in one or more holding registers. 06 Preset single register Place a specific binary value into a holding register. 16 Preset multiple registers Places specific binary values into a series of consecutive holding registers. 2.4 Data Field: The data field contains the information needed by the slave to perform the specific function or it contains data collected by the slave in response to a query. 2.5 Error Check Field: This allows the master and slave device to check a message for error transmission. 19

21 -19- The error check field uses a CRC-16 check in the RTU mode. 3. EXCEPTION RESPONSES Exception response is a notification of an error. The exception response codes are listed in the table 3-1.When a slave detects one of these errors, it sends a response to the master consisting of slave address, function code, error code and error check field. To indicate that the response is a notification of an error, the high order bit of the function code is set to 1. Table 3-1 CODE NAME MEANING 01 ILLEGAL FUNCTION The message function received is not an allowable action for slave. 02 ILLEGAL DATA ADDRESS The address referenced in the data field is not an allowable address for the addressed slave location. 03 ILLEGAL DATA VALUE The value referenced in the data field is not allowable in the addressed slave location. 20

22 -20- Example: Query Message SLAVE ADDR FNC H.O START ADDR L.O. START ADDR H.O NO. OF REG L.O NO. OF REG ERROR CHECK FIELD ERROR CHECK FIELD 0A FC BB The query requests the status of input 0036 in slave no.10. Since the function is an invalid function for the L&T meters so the following error response will be generated. Response Message SLAVE ADDR FUN C EXCEPTIO N CODE ERROR CHECK ERROR CHECK 0A F0 52 The function code field is the original function code with the high order bit set and exception code 01 indicates an illegal function field. 4. EXPLANATION OF VARIOUS FUNCTION The purpose of this section is to define the general format for the specific command available to programmers. The form of each query message (in RTU transmission mode) and an explanation of the function the query message performs are provided. All numbers in Modbus format are entered in hexadecimal. 21

23 Read Output Register (Function Code 03) Query Read output Register(03) allows the user to obtain the binary contents of holding register in the addressed slave. The addressing allows up to Max.90 registers to be obtained at each request. Broadcast mode is not allowed. The below example reads registers of 1st phase voltage from slave number 17(decimal). Since 1st phase voltage is stored in the address 0000 and 0001 so to read phase voltage both addresses should be read simultaneously. Example: SLAVE ADDR FNC H.O START ADDR Query Message L.O. H.O L.O START NO NO. ADDR OF OF REG REG ERROR CHECK FIELD ERROR CHECK FIELD C6 9B NOTE: If a particular parameter is stored in more than one address location. Then for reading that particular parameter all the address locations should be read simultaneously. Otherwise meter will not respond or the response will not be the correct value. For further details see memory map of parameters. 22

24 -22- Response: The addressed slave will respond with its address and the function code, followed by the information field. The information field contains 1 byte describing the quantity of data bytes to be returned. The contents of register requested (DATA) are two bytes each. The first byte includes the higher order bits and the second byte includes lower order bits. Response Message SLAVE ADDR FNC BTE COU NT DATA O/P REG DATA O/P REG DATA O/P REG DAT A O/P ERR. CHE. FLD ERR. CHK FLD H.O L.O H.O REG L.O D E6 52 E8 In this particular example the data obtained for 1st phase voltage is 0x00005DE6 which if converted into integer will be So to get the voltage of the phase this particular value should be multiplied with the specified multiplication factor(mf) which is 0.01 in this case. (For further details see the memory map of the parameters). So x 0.01= which is the phase voltage. 4.2 Preset Single Register (Function Code 06) CAUTION: Function (06) will overwrite controller memory. 23

25 -23- Function (06) allows the user to modify the contents of a holding register. The contents of only those holding registers can be modified which are write only. The values are provided in binary, up to the maximum capacity of the controller (16-Bits in L&T meters)and unused higher bits must be set to zero. When used with slave address zero(broadcast mode), all slave controllers will load the specified registers with the content specified. Example: This example will set the CT primary value in slave number 17.The address of CT primary is 2048 and value to be programmed is Query Message SLAVE ADDR FNC H.O START ADDR L.O. START ADDR DATA VAL. H.O DATA VAL. L.O ERR. CHK FLD ERR. CHK FLD E The normal response to a preset single register request is to transmit the query message after the register has been altered. Response Message SLAVE ADDR FNC H.O START ADDR L.O. START ADDR DATA VALUE H.O DATA VALUE L.O ERR. CHK FLD ERROR CHECK FIELD E

26 -24- If the value is an illegal value then the response message will be an exception response(error message). For the details of max. and min. values of any parameter, please refer to manual. NOTE: For programming RTC the values the data for setting the RTC should be BCD(Binary Coded Decimal). Example: For setting date 29 and day 5 at location 257 the query message will be as follows Query Message SLAVE ADDR FNC H.O START ADDR L.O. START ADDR DATA VALUE H.O DATA VALUE L.O ERR. CHK FLD ERR. CHK FLD F5 4.3 Preset Multiple Registers(Function Code 16) CAUTION: Function(16) will overwrite controller memory. Function(16) allows the user to modify the contents of holding registers. 25

27 AD DR -25- The contents of only those holding registers can be modified which are writeable only. The values are provided in binary up to the maximum capacity of the controller (16-Bits in L&T meters), unused higher bits must be set to zero. Maximum of 10 registers can be programmed by this function. When used with slave address zero(broadcast mode) all slave controllers will load the specified registers with the contents specified. Example: This example will set the CT primary and CT secondary value in slave number 17.The address of CT primary is 2048,CT secondary is 2049 and value to be programmed for CT primary and secondary are 1000 and 100 respectively. FU NC H.O. ADD L.O. ADD QTY. H.O Query Message QTY. L.O BYT SNT H.O DAT L.O DAT H.O DAT L.O DAT ERR FLD E The normal response to a preset multiple register request is to echo the address function code, starting address and number of registers to be loaded. 26 ERR FLD

28 -26- Response message SLAVE ADDR FNC H.O START ADDR L.O. START ADDR QTY H.O QTY L.O ERR. ERR. CHK FIELD CHK FLD

29 -27- Appendix 3: MEMORY MAP Read only Parameters ( Function Code 4): MEMORY MAP (Address list) Address Parameters Words MF (if no specific format is mentioned, format is HEX) READ ONLY PARAMETERS Instantaneous Parameters 30,001 Phase 1 Voltage ,003 Phase 2 Voltage ,005 Phase 3 Voltage * ,007 Phase 1 Current ,009 Phase 2 Current ,011 Phase 3 Current * ,013 Phase 1 Active Power ,015 Phase 2 Active Power ,017 Phase 3 Active Power * ,019 Phase 1 Reactive Power ,021 Phase 2 Reactive Power ,023 Phase 3 Reactive Power * ,025 Phase 1 Apparent Power ,027 Phase 2 Apparent Power

30 -28-30,029 Phase 3 Apparent Power * ,031 Phase 1 Power Factor ,033 Phase 2 Power Factor ,035 Phase 3 Power Factor * ,037 Total Active Power ,039 Total Reactive Power ,041 Total Apparent Power ,043 Total Power Factor Format:for above addresses 30,013 to 30,043 1 st word (MSW) 0x0000 if value positive 0xFFFF if value negative 2 nd word value itself, if positive as indicated by 1 st word 2 s complement of value, if negative as indicated by 1 st word 30,045 Line Frequency ,047 Reserved 2 30,049 Phase 1 Voltage Angle ,051 Phase 2 Voltage Angle ,053 Phase 3 Voltage Angle * ,055 Phase 1 Phase Angle ,057 Phase 2 Phase Angle ,059 Phase 3 Phase Angle * ,061 Phase 1 Voltage Fundamental ,063 Phase 2 Voltage Fundamental

31 -29-30,065 Phase 3 Voltage Fundamental * ,067 Phase 1 Voltage Distortion ,069 Phase 2 Voltage Distortion ,071 Phase 3 Voltage Distortion * ,073 Phase 1 Current Fundamental ,075 Phase 2 Current Fundamental ,077 Phase 3 Current Fundamental * ,079 Phase 1 Current Distortion ,081 Phase 2 Current Distortion ,083 Phase 3 Current Distortion * ,085 Average Voltage ,087 Average Current Minimum / Maximum of Instantaneous Parameters 30,129 Minimum Phase 1 Voltage ,131 Minimum Phase 2 Voltage ,133 Minimum Phase 3 Voltage * ,135 Maximum Phase 1 Voltage ,137 Maximum Phase 2 Voltage ,139 Maximum Phase 3 Voltage * ,141 Minimum Phase 1 Current ,143 Minimum Phase 2 Current

32 -30-30,145 Minimum Phase 3 Current * ,147 Maximum Phase 1 Current ,149 Maximum Phase 2 Current ,151 Maximum Phase 3 Current * ,153 Minimum Phase 1 Power Factor ,155 Minimum Phase 2 Power Factor ,157 Minimum Phase 3 power Factor * ,159 Maximum Phase 1 Power Factor ,161 Maximum Phase 2 power Factor ,163 Maximum Phase 3 Power Factor * ,165 Minimum Average Voltage ,167 Maximum Average Voltage ,169 Minimum Average Current ,171 Maximum Average Current ,173 Minimum Average Power Factor ,175 Maximum Average Power Factor ,177 Minimum Frequency ,179 Maximum Frequency ,181 Minimum Total Active power ,183 Maximum Total Active power ,185 Minimum Total Reactive power ,187 Maximum Total Reactive power

33 -31-30,189 Minimum Total Apparent Power ,191 Maximum Total Apparent Power ,193 Minimum Power Demand ,195 Maximum Power Demand Read Only Parameters (Function Code 4): Cumulative energies since installation independent of Tarifs. 30,513 Cumulative energy - forward kvah ,515 Cumulative energy - forward kwh ,517 Cumulative energy - forward kvarh lag ,519 Cumulative energy - forward kvarh lead Read Only Parameters (Function Code 4): 31,281 Power Demand

34 -32- Read Write Parameters (Supported by function code 6 and 16 for Writing and by function code 3 for Reading.) Communication Parameters 42,385 Meter Address ,386 Baud Rate 1 1 Format: 1 -> > > > > > ,387 Parity 1 1 Format : 0 -> None Parity 1 -> Odd Parity 2 -> Even Parity CT PT ratio settings (1 to 9999 max) 42,049 CT Primary ,050 CT Secondary ,051 PT Primary ,052 PT Secondary 1 1 (max. CTpri/Ctsec)*(PTpri/Ptsec) <=

35 -33- MD Settings 42,161 Setting for MD 2 1 Format of MD Setting : 1 st Word : No of MD MD Type 2 ND Word : Intg. Period Sub.Intg. Period No.of MDs : 1 (Only one energy register is available) MD Type : 0 or 1 Forward 0-kVA, 1-kW, Intg. Period : 1,2,3,4,5,6,10,12,15,20,30,60 min. Sub.Intg. Period : Sub.Intg Period is egual to Intg.period * - The Parameter is supported only in four wire meters. In three wire meter the query for this parameter is replied with Zeros. 34

36 Notes : -34- The above are supported by function code 6 and 16 for writing and by function code 3 for reading. * - The Parameter is supported only in four wire meters. In three wire meter the query for this parameter is replied with Zeros...35

37 -35- Appendix 4 Procedure for front panel programming of QUASAR Programming of various parameters in Quasar is done by Selecting the appropriate screen and changing the parameters. Following sections explain the setting procedure. 1.0 Entering into programming mode : Prog Pass 0000 Press both Mode & Up buttons together. Screen will appear as shown. First digit will flash. You have to set Pass password. 1.1 Entering the pass word: Let us say password is Press Up button to change the value of the flashing digit. Press Rst button to shift to next digit. Press Up button to change its value. Set 1234 in all digits. Press mode. Meter will display PW accepted momentarily and go to a new screen ctpt rat. 2.0 Selecting the parameters to be set : Once the meter is at above screen, the user can select a screen to set any of the following paramerters Ctpt rat Change ratios of CTs and PTs Clr data Reset the MD value and cumulative energy values. Set MD You can set the integration time and choose either kw or kva for integration. Set Id set the node address of meter.36

38 Set Port Set Disp Set Pass -36- set the baud rate for communication set the default display screen set the pass word Press Up button to choose any of the above screens. 3.0 Setting CT/PT Ratio 0100 ct prmy Reach the screen ctpt rat as explained above. Press Mode. Display shows existing CT primary rating. First digit will flash. Change the value by using Up and Rst buttons. Say you have set CT primary as ct prmy 0001 ct secy After seting the required value press mode. Meter will display L up date. Press mode again. Meter will display accepted briefly and return to display as shown. Press Down button to go to ct secy. Press Mode. Display shows existing CT secondary rating. First digit will flash. Change the value by Up and Rst buttons. Say you have set CT secondary as After seting the required value press mode. Meter will display L up date. Press mode again. Meter will display accepted briefly and return to display as shown. Press Down button to go to pt prmy..37

39 -37- Set the ratings of PT primary and secondary in the same manner as explained above. After finishing with PT Secondary, press Down button. Meter will display escape and return to ctpt rat.. Press Up button to go to next screen clr data. 4.0 Clearing the existing data : After reaching the screen clr data, press mode. Display will change to clr dmd. Press mode. Display will be L up date. Press mode. Display will be accepted followed by clr dmd. Press up button. Display will change to clr egy. Press mode. Display will be L up date. Press mode. Dis[lay will be accepted followed by clr egy. Press Down button. Display will show escape followed by clr data. Press Up button. Display will enter next screen Set MD. 5.0 Setting the Demand parameters : 30 md intg After reaching the screen set md, press mode. Display will show existing value for MD integration time. The value will be flashing. By pressing Up button change the value to required setting. Press Mode. Display will show L update. Press mode again. Disply will show accepted followed by the up dated screen. Press Up button. Display will show md kw. Press mode. KW will flash...38

40 -38- By using up button choose kw or kva. Press mode. Display will show L up date. Press mode again. Display will show accepted followed by Md kw. Press down button to escape followed by Set Md. Press up button to go to next screen Set Id. 6.0 Setting the node address for meter: After reaching the screen Set Id, press mode. Display 001 will show existing value for Meter Id. The value will Meter Id be flashing. By pressing Up button change the value to required setting. Press Mode. Display will show L update. Press mode again. Disply will show accepted followed by Set Id screen. Press Up button to go to the next screen Set Port. 7.0 Setting the port characteristics: After reaching the screen Set Port, press mode Display will show existing value for baud rate. Press baud rate mode. The value will be flashing. By pressing Up button change the value to required setting. Press Mode. Display will show L update. Press mode again. Disply will show accepted followed by up dated screen. 39

41 even parity -39- Press Up button. Display will change to parity setting screen as shown. Press mode. The parameter even will flash. Using Up button choose even or odd or none parity. Press mode. Display will change to L up date. Press mode again. Display will show accepted followed by up dated screen. Press Down button. Display will show escape followed by Set Port. Press up button to go to next screen Set Disp. 8.0 Setting the default display After reaching the screen Set Disp, press mode. 00 position Display will show existing default screen number. Press mode. The number will be flashing. By pressing Up button change screen number which will become default screen. Press mode. Display will show L update. Press mode again. Disply will show accepted followed by up dated screen. button to go to the next screen Set Pass. Press Up 9.0 Setting the pass word: After reaching the screen Set Pass, press mode pass ord Display will show existing pass word screen as shown. Press mode. The number will be flashing. By pressing Up button change the number into required new pass word. 40

42 -40- Press mode. Display will show L update. Press mode again. Disply will show accepted followed by Set pass screen. Press Up button to go to the next screen Set Pass. Press down button to escape. Meter will return to normal display mode. 41

43 Appendix 5 Display screens -41 Screen 1 Ave. Power, Volts & Amps Screen 2 3Ph. Voltages Screen 3 3Ph. Currents Screen 4 Inst. 3Ph. Active Power Screen 5 Inst. 3Ph. Reactive Power 42

44 -42- Screen 6 Inst. 3Ph. Apparent Power Screen 7 Inst. 3Ph. Power Factor Screen 8 Voltage angles Screen 9 Phase angles Screen 10 Total Active, Reactive & Apparent Power Screen 11 Power demand, Total PF & Frequency 43

45 -43- Screen 12 Cum. Active Energy Screen 13 Cum. Inductive Energy Screen 14 Cum. Capacitive Energy Screen 15 Cum. Apparent Energy Screen 16 Ph 1 - Total, Fundamental & Distortion Voltages Screen 17 Ph 2 - Total, Fundamental & Distortion Voltages..44

46 -44- Screen 18 Ph 3 - Total, Fundamental & Distortion Voltages Screen 19 Ph1 - Total, Fundamental & Distortion Currents Screen 20 Ph2 - Total, Fundamental & Distortion Currents Screen 21 Ph3 - Total, Fundamental & Distortion Currents 45

47 -45- Appendix 6 Wiring Diagram - 3 Ph. 4 Wire with CT & PT.46

48 -46- Wiring Diagram - 3 Ph. 4 Wire with CT & without PT 47

49 -47- Wiring Diagram - 3 Ph. 3 Wire with CT & PT 48

50 -48- Wiring Diagram - 3 Ph.3 Wire with CT & without PT.49

51 Appendix 7 Dimensional details -49-

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual USER S MANUAL EMPOWER POWER METER This document contains the latest technical information about Empower which is a micro-controller based Power meter. The product Empower is sophisticated electronic equipment,

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

Contents. Introduction and description Package contents Device identification PM Options... 80

Contents. Introduction and description Package contents Device identification PM Options... 80 Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections

More information

MODBUS RS485 SERIAL PROTOCOL

MODBUS RS485 SERIAL PROTOCOL MODBUS RS485 SERIAL PROTOCOL ED39DIN DMM3 VIP39DIN VIP396 SIRIO STAR3 STAR3din VERSION 09 JULY 2004 Modbus SIRIO.doc 09 JULY 2004 Pag.1/22 The STAR3, STAR3 din, VIP396, VIP39din, DMM3, SIRIO and ED39din

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

TNM96-ETL Energy Meter & Electrical Powermeter

TNM96-ETL Energy Meter & Electrical Powermeter TNM96-ETL Energy Meter & Electrical Powermeter Celsa Messgeräte GmbH Barthelsmühlring 16, 76870 Kande - Germany Telefon: +49 7275 9883-0; Telefax: +49 7275 9883-33 Web: www.celsagermany.com; E-Mail: info@celsagermany.com

More information

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

TAS APFC Controller / Load Managers with MOD-BUS Interface

TAS APFC Controller / Load Managers with MOD-BUS Interface TAS APFC Controller / Load Managers with MOD-BUS Interface Designed & Prepared by TAS PowerTek Pvt. Ltd., W-61, MIDC Ambad, Nasik-422010, India. Updated on: 4th June 2017, Sunday. Data Parameter Field

More information

Installation and Operating Instructions

Installation and Operating Instructions Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

PM-PA/PM-PAC POWER ANALYZER

PM-PA/PM-PAC POWER ANALYZER PM-PA/PM-PAC POWER ANALYZER 1. INTRODUCTION Power Analyzer is an ideal device to control measure and monitor all electrical parameters of a system. Thanks to its four display rows, all parameters can be

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

DPF-MAC Auto power factor controller

DPF-MAC Auto power factor controller Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power

More information

Modular Metering System ModbusTCP Communications Manual

Modular Metering System ModbusTCP Communications Manual Modular Metering System Manual Revision 7 Published October 2016 Northern Design Metering Solutions Modular Metering System ModbusTCP 1 Description The multicube modular electricity metering system simultaneously

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Ziegler EM 1320/30/40

Ziegler EM 1320/30/40 Ziegler EM 1320/30/40 Operating Manual Ziegler EM 1340 2-60-006-00-00483_Rev. C - 9/2014 www.ziegler-instruments.com 1 36 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation

More information

ELECTRICAL VARIABLE ANALYZER RELAY EVAR

ELECTRICAL VARIABLE ANALYZER RELAY EVAR ELECTRICAL VARIABLE ANALYZER RELAY EVAR 1 ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this

More information

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3 POWER SERIES Plus Volt / Amp / Hertz Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM112 Energy Management Energy Analyzer Type EM112 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

Operating Guide October 2006

Operating Guide October 2006 Operating Guide October 2006 Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

ZHUHAI PILOT TECHNOLOGY CO., LTD.

ZHUHAI PILOT TECHNOLOGY CO., LTD. SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Installation Instructions and Reference Handbook. Installation instructions

Installation Instructions and Reference Handbook. Installation instructions Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Installation & Operation Manual ELNet VIP

Installation & Operation Manual ELNet VIP Installation & Operation Manual ELNet VIP Electrical Measurements Table of Contents 1. Mechanical Installation... 1-3 2. Wiring diagram... 2-5 3. Specifications... 3-6 Technical Specifications... 3-6 Measuring

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1

DIRIS Ap RS485 JBUS/MODBUS COM. Systèmes de Coupure et de Protection Industrial Switching and Protection Systems ON 1 DIRIS Ap RS485 JBUS/MODBUS F GB ON 1 D COM I NL E P Systèmes de Coupure et de Protection Industrial Switching and Protection Systems PRELIMINARY OPERATIONS NB: For personnel and product safety please read

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

Energy Management Energy Analyzer Type EM111

Energy Management Energy Analyzer Type EM111 Energy Management Energy Analyzer Type EM111 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

VIP Current & Power Multimeter

VIP Current & Power Multimeter VIP Current & Power Multimeter Rev 1.6 Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4.

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS ASCII Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the

More information

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p

Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p Installation Guide Tegra 710 and 810 Digital metering with RS485 Modbus TM o/p Introduction This manual provides operating and installation instructions for the Tegra 710 and 810 multifunction digital

More information

H8238/MCM MODBUS POINT MAP

H8238/MCM MODBUS POINT MAP H8238/MCM MODBUS POINT MAP F O R M A T Int Float R/W NV Description 1 257/258 R/W NV Energy Consumption, kwh, Low-word integer 2 259/260 R/W NV Energy Consumption, kwh, High-word integer Both 257/258 and

More information

Single phase energy meter with Serial Modbus interface

Single phase energy meter with Serial Modbus interface Data sheet www.sbc-support.com Single phase energy meter with Serial Modbus interface Energy meters with a Serial RS-485 Modbus interface allow direct reading of all relevant data, such as energy (total

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM111 Energy Management Energy Meter Type EM111 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter

More information

SERIES PM172 POWERMETERS COMMUNICATIONS. DNP Communications Protocol REFERENCE GUIDE

SERIES PM172 POWERMETERS COMMUNICATIONS. DNP Communications Protocol REFERENCE GUIDE SERIES PM172 POWERMETERS COMMUNICATIONS DNP3-2000 Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the manufacturer

More information

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter Type EM21 72R Retro-Fit Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class

More information

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM112 Energy Management Energy Meter Type EM112 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter

More information

PowerPlex PowerPlex. DNP3 Interface Option Manual. June 15, 2010 ML0009 Document Revision C 2010 by Bitronics, LLC

PowerPlex PowerPlex. DNP3 Interface Option Manual. June 15, 2010 ML0009 Document Revision C 2010 by Bitronics, LLC PowerPlex PowerPlex DNP3 Interface Option Manual June 15, 2010 ML000 Document Revision C 2010 by ronics, LLC -S530 (formerly DOS53) RS-232C DNP3 Protocol -S540 (formerly DOS54) RS-45 DNP3 Protocol Firmware

More information

Series PM130 PLUS Powermeters PM130P/PM130E/PM130EH

Series PM130 PLUS Powermeters PM130P/PM130E/PM130EH Series PM30 PLUS Powermeters PM30PPM30EPM30EH DNP3 Communications Protocol Reference Guide BG048 Rev. A4 Every effort has been made to ensure that the material herein is complete and accurate. However,

More information

Energy Management Energy Meter Type EM340

Energy Management Energy Meter Type EM340 Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order

More information

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network

More information

745 Transformer Protection System Communications Guide

745 Transformer Protection System Communications Guide Digital Energy Multilin 745 Transformer Protection System Communications Guide 745 revision: 5.20 GE publication code: GEK-106636E GE Multilin part number: 1601-0162-A6 Copyright 2010 GE Multilin GE Multilin

More information

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Analyzer Type EM210 MID Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3

More information

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter GM3T E GM3T-RS485 E Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit

More information

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP Table of Contents 2 FW Release summary Y Y Y Y Y Y PM RS FW History Y Y Y PM_2 OS FW History Y Y Y PM_2 RS FW History Y Y Y Setup & Status Metering Min Max Demand IO Alarms N N Reset Commands DL System

More information

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL GIMA Multi-Function Electricity Meter OPERATOR S MANUAL SIMPSON ELECTRIC COMPANY 520 Simpson Avenue Lac du Flambeau, WI 54538 715-588-3311 FAX: 715-588-7930 Printed in U.S.A. Part No. 06-117285, Edition

More information

SUPPLY NETWORK ANALYZER

SUPPLY NETWORK ANALYZER SUPPLY NETWORK ANALYZER CVM-144 SERIES (Ethernet) (Ver 6.11 and higher) INSTRUCTION MANUAL (M98203401-03-06A) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 ------ User's manual --- Page No. 1 CONTENTS

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014 Operating Manual RISH EM 1320/30/40 1 2-60-006-00-00483_Rev. C - 9/2014 2 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation & Operating Instructions Section Contents

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM] Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High

More information

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202 DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase

More information

EIG DNP V3.0 Protocol Assignments

EIG DNP V3.0 Protocol Assignments E Electro Industries/G augetech "The Leader in Web Accessed Power Monitoring" EIG DNP V3.0 Protocol Assignments For Futura+ and DM Series Power Monitors Version 1.14 July 15, 2003 Doc # E100-7-03 V1.14

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

3 phase energy meters with integrated Serial Modbus interface

3 phase energy meters with integrated Serial Modbus interface Data sheet www.sbc-support.com 3 phase energy meters with integrated Serial Modbus interface Energy meters with an integrated Serial RS-485 Modbus interface allow direct reading of all relevant data, such

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

ULTRA RAPID POWER QUALITY ANALYZER

ULTRA RAPID POWER QUALITY ANALYZER ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with

More information

Energy Management Energy Analyzer Type EM270-72D

Energy Management Energy Analyzer Type EM270-72D Energy Management Energy Analyzer Type EM270-72D RS485 dual port for daisy chain connection (optional) 2 programmable pulsating outputs (optional) Easy connections management (selectable) disabled by default

More information

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003 9.0 WARRANTY Table of Contents ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the

More information

E50 MODBUS POINT MAP

E50 MODBUS POINT MAP E50 MODBUS POINT MAP The E50C2 Full Data Set (FDS) features data outputs such as demand calculations, per phase VA and VAR, and VAh VARh accumulators. The E50C3 Data Logging model adds configuration registers

More information

POWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M A CIRCUTOR, SA

POWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M A CIRCUTOR, SA POWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M98174001-03-15A CIRCUTOR, SA CONTENTS 1 BASIC INSTRUCTIONS... 3 1.1 Checks on receipt.... 3 1.2 Main features... 3 1.3 Electrical parameters... 3 1.4

More information

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006 PRI Ltd. 9600-3004-2 Issue C Information contained within this document is subject to change without notice and does not represent

More information

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM210 Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)

More information

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups

DIRIS A40/A41 RS485 PROFIBUS DP. Operating instructions F GB D I NL E P. SOCOMEC GROUP switching PROTECTION & ups DIRIS A40/A41 RS485 PROFIBUS DP Operating instructions F GB D I NL E P SOCOMEC GROUP switching PROTECTION & ups 2 DIRIS A20 - Réf. : 536 182 A GB 876_786_A_gb.indd 2 3/04/09 10:50:47 GB Contents PRELIMINARY

More information

EM-72 Electricity Meters for Current Transformers

EM-72 Electricity Meters for Current Transformers Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the

More information

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03 Multimeter 560CVD03 Without LCD Display There are several versions available: With LCD Display Figure 1 Type Display LO HI 1A 5A Versions R0031 3U3I x x x R0035 3U3I x x x R0051 3U3I x x x R0055 3U3I x

More information

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification

DIRIS A40/A41 RS485 PROFIBUS DP COM. Operating instructions. PROFIBUS Certification DIRIS A40/A41 RS485 PROFIBUS DP Operating instructions F GB D I NL E P ON 1 COM PROFIBUS Certification SOCOMEC GROUP SWITCHING PROTECTION & UPS Systèmes de Coupure et de Protection Industrial Switching

More information

Universal-Transducer Multi-E11-MU

Universal-Transducer Multi-E11-MU Universal-Transducer Multi-E11-MU Safety Informations Observe instructions! The device described in these instructions shall only be installed by a qualified electrician according to both EN 50110-1/-2

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. PMAC770 Multifunction Power Meter Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals. The manufacturer shall not

More information

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

CVM-C5-ITF-485 CVM-C5-MC-485

CVM-C5-ITF-485 CVM-C5-MC-485 Power analyzer CVM-C5-ITF-485 CVM-C5-MC-485 CVM-C5-mV-485 INSTRUCTION MANUAL (M026B01-03-18A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below DANGER Warns

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

RISH Master 3440i/3440iDL 0.2S

RISH Master 3440i/3440iDL 0.2S Operating Manual RISH Master 3440i/3440iDL 0.2S as per IEC62053-22 Touch Screen Digital Multi-Function Meter Installation & Operating Instructions Section Contents 1. Introduction INDEX 2. Measurement

More information

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM280-72D Energy Management Energy Analyzer Type EM280-72D Equivalent to Class 1 (kwh) of EN62053-21 (EM280 base only) Equivalent to Class 2 (kvarh) of EN62053-23 (EM280 base only) Virtual meter (sum of two 3-phase

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual.   en/countis-e2x Instruction manual COUNTIS E23/E24 Three-phase energy meter Direct - 80 A MODBUS COUNTIS E23 COUNTIS E24 - MID www.socomec.com/ en/countis-e2x Contents 1. Documentation.... 3 2. Hazards and warnings...

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

User's Manual. Clamp-on Power Datalogger. Model

User's Manual. Clamp-on Power Datalogger. Model User's Manual Clamp-on Power Datalogger Model 382060 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS PREMIER INSTALLATION AND OPERATING INSTRUCTIONS Copyright 2002-2006, PRI Ltd. 9600-3003-2 Issue C Information contained within this document is subject to change without notice and does not represent a

More information

SUPPLY NETWORK ANALYZER

SUPPLY NETWORK ANALYZER SUPPLY NETWORK ANALYZER CVM-144 SERIES (PROFIBUS-DP) INSTRUCTION MANUAL ( M 981 704 / 01A - GB) CIRCUTOR S.A. ----- Supply network analyzer CVM-144 (PROFIBUS) ------ --- Page No. 1 CONTENTS page 1.- DELIVERY

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information