MB Scientific AB Extremely High Energy Resolution Photoelectron Analyser

Size: px
Start display at page:

Download "MB Scientific AB Extremely High Energy Resolution Photoelectron Analyser"

Transcription

1 December 2014 Product catalogue MB Scientific AB Extremely High Energy Resolution Photoelectron Analyser Model : MBS A-1 and Lens4 A-1 with Lens4 Outlook photo* *System might deviate from the picture depending on the options. Page1

2 General design & Speciality Hemispherical Electron Energy Analyser mm mean radius hemispherical electrostatic analyser with 2 layer Permalloy screen kV Compatible 3. High transmission hemisphere system with 9 slit pairs 50 m to 3.2 mm. 4. Light weight, low outgassing Permalloy vacuum case. 5. Flexible Detector Options: MCP/CCD, Spin, Delay Line. Multifunction Electrostatic Wide Angle Acceptance Zoom Lens 'L4' with Angular Scan function 1. Wide input acceptance angle with 35 mm working distance. 2. Multiple angular modes: 4, 7 and 36 degree total acceptance standard set 3. In vacuum adjustable lens axis 4. Very good focusing and flexibility by using 7 elements and electrostatic x-y deflector. 5. Angular Scan mode takes about ±15 degree perpendicular to the analyser slit without tilting sample. 2-D Detector and Detection System m c/c hexagonal retarding mesh, flat 'artefact-free' type. 2. Increased sensitivity and homogeneity with GigE Megapixel CCD camera. 3. Advanced real time image processing eliminates curved slits. Ultra High Performance Electronics 1. USB 2 Interface 2. LabView application delivered with source code 3. Completely modular system; All modules are easily exchanged by customer. 4. Energy Step Size down to (Channel Width/4) in swept mode. 5. Virtually unlimited number of independent voltages 6. High speed 8Mb/s RS485 internal communication bus. 7. Fast 16 or18 bit 1 khz pulse width modulator (PWM) control. 8. Ultra high stability & Ultra low noise level, 0.25 ppm /4 h rms typical random drift.. 9. Linearity 1 ppm typ. 10. Stable operation down to zero voltage setting by Patented (SE ) Flower current sink. 11. No slow and messy optical fibres, uses on-board 2 ns electromagnetic 15 kv isolation barrier. 12. Fast, precise D/A converters. 50 μv, 100 μv or 200 μv scanning step size options. Page2

3 Detailed Standard Specifications 1. Energy resolution at Ep 1eV with 0.2mm Less than 1.2 mev FWHM straight slit and less than 100eV kinetic energy. Typ. 0.8 mev 2. Energy resolution at Ep 2eV with 0.2mm Less than 1.6 mev FWHM straight slit and less than 100eV kinetic energy. Typ. 1.2 mev 3. Energy resolution at Ep 5eV with 0.2mm Less than 3.5 mev FWHM straight slit and less than 100eV kinetic energy. Typ. 2.8 mev 4. Resolving power Ep/ΔE at Ep 10 ev More than 1500 FWHM and 0.2mm straight slit. Typ Angular Resolution (along the slit) within an angular Less than 0.1 degree* (Ang3d9) interval of ±3.5 degree. 6. Angular Resolution (along the slit) within an angular Less than 0.5 degree* (Ang1d6) interval of ±8 degree. 7. Angular Resolution (along the slit)within an angular Less than 1 degree *(Ang0d6) interval of ±18 degree. *At less than 0.5 mm Φ emission spot size. At smaller emission spot sizes the resolution will be improved 8. Standard Lens modes Spat5: High transmission mode, five times linear magnified image of the sample focussed at the analyser entrance slit. Ang3d9: Ang1d6: Ang0d6: Angular resolving mode, 3.9 mm/degree dispersion at the analyser entrance slit. Angular resolving mode, 1.6 mm/degree dispersion at the analyser entrance slit. Wide Angular resolving mode, 0.6 mm/degree dispersion at the analyser entrance slit. Ang3d7 Epass5 Ang1d6 Epass5 Ang0d6 Epass5 9. Angular Scan modes Yes! (see page 8 to 12) Page3

4 10. Predefined pass energies UPS : 1, 2, 5, 10, 20 ev XPS and higher : 20, 50, 100, 200 ev 11. Applicable kinetic energy range UPS ev XPS ev Optional HIGH 0-6keV Optional HAXPES 0-12 kev Optional 12. Standard Slit Set 9 pairs of 25 mm long BeCu slits Straight: 0.05, 0.1, 0.1(wide aperture), 0.2, 0.4, 0.8, 1.6, 3.2 Curved: 0.2 mm with 1 mm Aperture for adjustments 13. Working distance between the lens and sample 35 mm MBS A-1 analyser with lens3 Performance of Electronics 1. Pulse Width Modulator (PWM) high precision supplies 1 Stability 1 ppm/k, 0.3 ppm/4h rms. 2 Resolution or steps. 3 Linearity ±1 ppm of full scale output. 4 Max static load 50 μa 5 Max capacitive load 30 nf 6 Absorption capability of Flower current sink; 20 μa 7 Max floating voltage; 6 kv versus ground of any terminal. Page4

5 2. High Precision DAC modules 1 Type of DAC 2 Step Size (Selectable at time of order) 3 Resolution 4 Linearity (w/o compensation table) 5 Standard Compensation Table 6 Voltage Span 7 Stability 8 Max static load 9 Max capacitive load 10 Max Floating Voltage Double Ladder, guaranteed monotonic, 5μs settling with linearization table. 50, 100 or 200 μv 17 Bits <0.01% of Max Voltage 51 points , ±6.55 or ±13.1 Volts Typ. 1 bit/year 1 ma 30 nf 6 kv. 3. Mains Power consumption V, Max 2A, 50-60Hz 4. 2-D Electron detector Dual MCP plus fibre optic phosphor screen. GigE high sensitivity CCD camera readout 5. MCP detection area 41 mm (25 mm*32 mm active) 6. Data acquisition mode Swept, Fixed, Rapid frames, 2D Angular Scan. 7. Communication interface to PC USB Interface program* LabVIEW v.i. or.exe *Attention: LabView License is NOT included. Open or modify the source code it is required LabView license 9. Flexibility adding function to the PC software Delivered with source code 10. Flexibility adding modules to the Voltage Supply Up to 254 PWM or DAC cards 11. Flexibility adding Pass Energies and Lens Modes Unlimited number easily defined Page5

6 Contents of standard set No. Amount Part 1. One set A-1 Analyser with Lens L4 2. One set A-1 Electronics 3. Five set A-1 Filterbox with cables and protective caps 4. One set Manta G-125 (or better) GigE CCD camera with adjustable mount 5. One set LabVIEW v.i.* 6. One A-1 Instrument Manual (English) 7. One A-1 Detector protective case 8. One 36mm wrench for filterbox connection Page6

7 Energy Resolution -----Better than 1meV The following data was obtained by Prof. Dr. Akira Sekiyama and Prof. Dr. Takayuki Kiss at Osaka University, Japan. The system consists of MBS A1 (#0014) with newly developed narrow band UV laser system as excitation. Fig. a (Left) Ultrahigh-resolution (< 1 mev) photoemission spectra of gold at hν = 5.9 ev. (Right) Temperature dependence of the spectra for Nb across a superconducting transition at ~9 K with the energy resolution of 1.1 mev. The following data (fig.b) was obtained by Dr. Seigo Souma at Tohoku University, Japan. The system consists of MBS A1 (#0010) with mini Mott type spin option, MBS T1 multi gas light source, in this case using Xenon gas excitation. Page7

8 MB Scientific AB A-1 Lens 4 New Angular Scan Lens is now able to take angular mapping without moving sample! Standard Angular Mode Data Angular Mapping Mode Data Өx Өx Ek (ev) Өy Page8

9 Test data taken by A-1 analyser_#0022 Date of data taken: File name: A3D0009_00.txt Data size: 2,046KB Page9

10 Angular Image data handling by MBS A1Soft MBS A-1 analyser will be delivered together with MBS A1Soft.vi which is containing functions not only taking Angular image data but also viewing the data in 2D and 3D. Following pictures are screen shots from our A1Soft data viewer. Above screen shot is the start page of A1Soft.vi For viewing the 2D Angular mapping data it shall be used View Data For viewing the 3D Angular mapping data it shall be used View 3D. Page10

11 View Data can show the 2D Angular mapping data as below; View 3D show the data as follows; The 3D Angular mapping data can be analyzed by 3 axis. This is Ek and Өy; Page11

12 This is Ek and Өx (this data is same with ordinary angular mode data); This is Өy and Өx (Angular image) at specified energy; Page12

13 Graphene/SiC(0001) Angular Scan Data taken by Prof. Dr. K. Takahashi at Saga University Synchrotron Light Application Centre using MBS A-1_#0004 with lens4 TEST00014.txt Ep20, 1d6, Slit#3, KE[ , 0.02eV], DefX[ , 0.1], -34deg, 290pA/311mA flame100 x 2scans (~1hr) HeRampTEST00008.txt Ep20, 1d6, Slit#3, KE[ , 0.02eV], DefX[ , 0.1], 35deg flame100 x 3scans (~1.5hrs) Page13

14 MBS Policy MB Scientific AB contributes to the peaceful development of the world through the activities of our leading-edge R&D, commercialization of the products, sales and education. MBS Actions 1. Focus on customers satisfaction 2. Be always faithful towards our customers 3. Keep clear responsibility in the company 4. Provide the Best Products with Best Support to make our customer quickly producing world leading data. Seminariegatan 29B, SE , Uppsala, Sweden Tel: , Fax: Homepage: Page14

COMPONENTS FOR SURFACE ANALYSIS. The State of the Art Energy Analyzer Series

COMPONENTS FOR SURFACE ANALYSIS. The State of the Art Energy Analyzer Series Surface Analysis Technology Vacuum Components Surface Analysis System Software Computer Technology COMPONENTS FOR SURFACE ANALYSIS The State of the Art Energy Analyzer Series PHOIBOS 100/150 Superior performance

More information

Components for Surface Analysis PHOIBOS 150 WAL. Hemispherical Energy Analyzer with Wide Angle Lens

Components for Surface Analysis PHOIBOS 150 WAL. Hemispherical Energy Analyzer with Wide Angle Lens Customized Systems and Solutions Nanostructures and Thin Film Deposition Surface Analysis and Preparation Components Surface Science Applications Components for Surface Analysis PHOIBOS 150 WAL Hemispherical

More information

Quad 12-Bit Digital-to-Analog Converter (Serial Interface)

Quad 12-Bit Digital-to-Analog Converter (Serial Interface) Quad 1-Bit Digital-to-Analog Converter (Serial Interface) FEATURES COMPLETE QUAD DAC INCLUDES INTERNAL REFERENCES AND OUTPUT AMPLIFIERS GUARANTEED SPECIFICATIONS OVER TEMPERATURE GUARANTEED MONOTONIC OVER

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

190 nm (6.5 ev) Laser-ARPES. Laser ARPES using a Tunable ps UV Source

190 nm (6.5 ev) Laser-ARPES. Laser ARPES using a Tunable ps UV Source 190 nm (6. ev) Laser-ARPES Laser ARPES using a Tunable ps UV Source 1 190 nm (6. ev) UV Source Laser ARPES/ARUPS with a High-Power UV Source Tunable deep-uv pulses from 190... 21 nm (6.....77 ev) are available

More information

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Agilent 86146B Optical Spectrum Analyzer Technical Specifications Agilent 86146B Optical Spectrum Analyzer Technical Specifications November 2005 Full-Feature Optical Spectrum Analyzer Exhibits excellent speed and dynamic range with convenient and powerful user interface.

More information

Components for Surface Analysis PHOIBOS 150 NAP. Near Ambient Pressure Hemispherical Energy Analyzer

Components for Surface Analysis PHOIBOS 150 NAP. Near Ambient Pressure Hemispherical Energy Analyzer Customized Systems and Solutions Nanostructures and Thin Film Deposition Surface Analysis and Preparation Components Surface Science Applications Components for Surface Analysis PHOIBOS 150 NAP Near Ambient

More information

Electro Optical Components, Inc. SUNSTAR 传感与控制 TEL: FAX: Skylane Boulev

Electro Optical Components, Inc. SUNSTAR 传感与控制   TEL: FAX: Skylane Boulev Electro Optical Components, Inc. 5460 Skylane Boulevard, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Features Transimpedance (Gain) Switchable from 1 x 10 3 to 1 x 10

More information

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications 8614xB Optical Spectrum Analyzer Family Technical Specifications June 2005 Filter Mode Enables you to drop a single DWDM channel or measure time resolved chirp (TRC) and calculate dispersion penalty (DPC).

More information

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers Spectrometers HR2000+ Spectrometer User-Configured for Flexibility HR2000+ One of our most popular items, the HR2000+ Spectrometer features a high-resolution optical bench, a powerful 2-MHz analog-to-digital

More information

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER Voltage-to-Frequency and Frequency-to-Voltage CONVERTER FEATURES OPERATION UP TO 00kHz EXCELLENT LINEARITY ±0.0% max at 0kHz FS ±0.0% max at 00kHz FS V/F OR F/V CONVERSION MONOTONIC VOLTAGE OR CURRENT

More information

16-Bit ANALOG-TO-DIGITAL CONVERTER

16-Bit ANALOG-TO-DIGITAL CONVERTER 16-Bit ANALOG-TO-DIGITAL CONVERTER FEATURES 16-BIT RESOLUTION LINEARITY ERROR: ±0.003% max (KG, BG) NO MISSING CODES GUARANTEED FROM 25 C TO 85 C 17µs CONVERSION TIME (16-Bit) SERIAL AND PARALLEL OUTPUTS

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 21-23 Campus Road Contact: Mr K G Dove Listerhills Science Park Tel: +44 (0)1274 393857 Bradford Fax: +44 (0)1274 393336 BD7 1HR E-Mail: sales@otc.co.uk

More information

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels The PIXIS-XO series of fully integrated imaging cameras utilizes back-illuminated and back-illuminated deep depletion CCDs without AR coating, for direct detection of the widest range of X-rays between

More information

MXD7210GL/HL/ML/NL. Low Cost, Low Noise ±10 g Dual Axis Accelerometer with Digital Outputs

MXD7210GL/HL/ML/NL. Low Cost, Low Noise ±10 g Dual Axis Accelerometer with Digital Outputs FEATURES Low cost Resolution better than 1milli-g at 1Hz Dual axis accelerometer fabricated on a monolithic CMOS IC On chip mixed signal processing No moving parts; No loose particle issues >50,000 g shock

More information

SpectraPro 2150 Monochromators and Spectrographs

SpectraPro 2150 Monochromators and Spectrographs SpectraPro 215 Monochromators and Spectrographs SpectraPro 215 15 mm imaging spectrographs and monochromators from are the industry standard for researchers who demand the highest quality data. Acton monochromators

More information

Dual 16-Bit DIGITAL-TO-ANALOG CONVERTER

Dual 16-Bit DIGITAL-TO-ANALOG CONVERTER Dual - DIGITAL-TO-ANALOG CONVERTER FEATURES COMPLETE DUAL V OUT DAC DOUBLE-BUFFERED INPUT REGISTER HIGH-SPEED DATA INPUT: Serial or Parallel HIGH ACCURACY: ±0.003% Linearity Error 14-BIT MONOTONICITY OVER

More information

MXD6235Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES

MXD6235Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs MXD6235Q FEATURES Ultra Low Noise 0.13 mg/ Hz typical RoHS compliant Ultra Low Offset Drift 0.1 mg/ C typical Resolution better than

More information

PHY385H1F Introductory Optics Term Test 2 November 6, 2012 Duration: 50 minutes. NAME: Student Number:.

PHY385H1F Introductory Optics Term Test 2 November 6, 2012 Duration: 50 minutes. NAME: Student Number:. PHY385H1F Introductory Optics Term Test 2 November 6, 2012 Duration: 50 minutes NAME: Student Number:. Aids allowed: A pocket calculator with no communication ability. One 8.5x11 aid sheet, written on

More information

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels The PIXIS-XO series of fully integrated imaging cameras utilizes back-illuminated (BI) and back-illuminated, deepdepletion CCDs without AR coating, for direct detection of the widest range of X-rays between

More information

Low Cost, General Purpose High Speed JFET Amplifier AD825

Low Cost, General Purpose High Speed JFET Amplifier AD825 a FEATURES High Speed 41 MHz, 3 db Bandwidth 125 V/ s Slew Rate 8 ns Settling Time Input Bias Current of 2 pa and Noise Current of 1 fa/ Hz Input Voltage Noise of 12 nv/ Hz Fully Specified Power Supplies:

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection The PIXIS-XO series of fully integrated imaging cameras utilizes back-illuminated (BI) and back-illuminated, deepdepletion (BR)

More information

Picture 1 PC & USB Connection

Picture 1 PC & USB Connection USB Ethernet HART Profi-bus DeviceNet EtherCAT CANopen CAN RS Zigbee Analog Switch Vibration-wire PWM SSI CDMA GPRS Wi-Fi USB Inclinometer Features - Reference with USB2.0 protocol - P2P and compatible

More information

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER Voltage-to-Frequency and Frequency-to-Voltage CONVERTER FEATURES OPERATION UP TO 500kHz EXCELLENT LINEARITY ±0.0% max at 0kHz FS ±0.05% max at 00kHz FS V/F OR F/V CONVERSION MONOTONIC VOLTAGE OR CURRENT

More information

Precision, Micropower, Low-Dropout, SC70 Series Voltage Reference

Precision, Micropower, Low-Dropout, SC70 Series Voltage Reference 19-2428; Rev ; 4/2 Precision, Micropower, Low-Dropout, SC7 General Description The family of precision, low-dropout, micropower voltage references are available in the miniature 3-pin SC7 surface-mount

More information

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Takeshi Fujiwara 1, Yuki Mitsuya 2, Hiroyuki Takahashi 2, and Hiroyuki Toyokawa 2 1 National Institute of Advanced Industrial

More information

Experimental Analysis of Luminescence in Printed Materials

Experimental Analysis of Luminescence in Printed Materials Experimental Analysis of Luminescence in Printed Materials A. D. McGrath, S. M. Vaezi-Nejad Abstract - This paper is based on a printing industry research project nearing completion [1]. While luminescent

More information

Serial Input 18-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER

Serial Input 18-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER Serial Input 8-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER FEATURES 8-BIT MONOLITHIC AUDIO D/A CONVERTER LOW MAX THD + N: 92dB Without External Adjust 00% PIN COMPATIBLE WITH INDUSTRY STD 6-BIT PCM56P

More information

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first

More information

8-Bit A/D Converter AD673 REV. A FUNCTIONAL BLOCK DIAGRAM

8-Bit A/D Converter AD673 REV. A FUNCTIONAL BLOCK DIAGRAM a FEATURES Complete 8-Bit A/D Converter with Reference, Clock and Comparator 30 s Maximum Conversion Time Full 8- or 16-Bit Microprocessor Bus Interface Unipolar and Bipolar Inputs No Missing Codes Over

More information

LM199/LM299/LM399/LM3999 Precision Reference

LM199/LM299/LM399/LM3999 Precision Reference LM199/LM299/LM399/LM3999 Precision Reference General Description The LM199 series are precision, temperature-stabilized monolithic zeners offering temperature coefficients a factor of ten better than high

More information

Serial Input 18-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER

Serial Input 18-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER Serial Input 8-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER FEATURES 8-BIT MONOLITHIC AUDIO D/A CONVERTER LOW MAX THD + N: 92dB Without External Adjust 00% PIN COMPATIBLE WITH INDUSTRY STD 6-BIT PCM56P

More information

Voltage-to-Frequency and Frequency-to-Voltage Converter ADVFC32

Voltage-to-Frequency and Frequency-to-Voltage Converter ADVFC32 a FEATURES High Linearity 0.01% max at 10 khz FS 0.05% max at 100 khz FS 0.2% max at 500 khz FS Output TTL/CMOS Compatible V/F or F/V Conversion 6 Decade Dynamic Range Voltage or Current Input Reliable

More information

AD9300 SPECIFICATIONS ELECTRICAL CHARACTERISTICS ( V S = 12 V 5%; C L = 10 pf; R L = 2 k, unless otherwise noted) COMMERCIAL 0 C to +70 C Test AD9300K

AD9300 SPECIFICATIONS ELECTRICAL CHARACTERISTICS ( V S = 12 V 5%; C L = 10 pf; R L = 2 k, unless otherwise noted) COMMERCIAL 0 C to +70 C Test AD9300K a FEATURES 34 MHz Full Power Bandwidth 0.1 db Gain Flatness to 8 MHz 72 db Crosstalk Rejection @ 10 MHz 0.03 /0.01% Differential Phase/Gain Cascadable for Switch Matrices MIL-STD-883 Compliant Versions

More information

DACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557*

DACPORT Low Cost, Complete P-Compatible 8-Bit DAC AD557* a FEATURES Complete 8-Bit DAC Voltage Output 0 V to 2.56 V Internal Precision Band-Gap Reference Single-Supply Operation: 5 V ( 10%) Full Microprocessor Interface Fast: 1 s Voltage Settling to 1/2 LSB

More information

High Precision 10 V IC Reference AD581*

High Precision 10 V IC Reference AD581* a FEATURES Laser Trimmed to High Accuracy: 10.000 Volts 5 mv (L and U) Trimmed Temperature Coefficient: 5 ppm/ C max, 0 C to +70 C (L) 10 ppm/ C max, 55 C to +125 C (U) Excellent Long-Term Stability: 25

More information

CMOS 8-Bit Buffered Multiplying DAC AD7524

CMOS 8-Bit Buffered Multiplying DAC AD7524 a FEATURES Microprocessor Compatible (6800, 8085, Z80, Etc.) TTL/ CMOS Compatible Inputs On-Chip Data Latches Endpoint Linearity Low Power Consumption Monotonicity Guaranteed (Full Temperature Range) Latch

More information

MXD6125Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES

MXD6125Q. Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs FEATURES Ultra High Performance ±1g Dual Axis Accelerometer with Digital Outputs MXD6125Q FEATURES Ultra Low Noise 0.13 mg/ Hz typical RoHS compliant Ultra Low Offset Drift 0.1 mg/ C typical Resolution better than

More information

Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER

Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER www.burr-brown.com/databook/.html Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER FEATURES LOW DISTORTION:.3% at khz LOW NOISE: nv/ Hz HIGH SLEW RATE: 25V/µs WIDE GAIN-BANDWIDTH: MHz UNITY-GAIN STABLE

More information

Introduction of New Products

Introduction of New Products Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can

More information

Microprocessor-Compatible 12-Bit D/A Converter AD667*

Microprocessor-Compatible 12-Bit D/A Converter AD667* a FEATURES Complete 12-Bit D/A Function Double-Buffered Latch On Chip Output Amplifier High Stability Buried Zener Reference Single Chip Construction Monotonicity Guaranteed Over Temperature Linearity

More information

Monolithic SAMPLE/HOLD AMPLIFIER

Monolithic SAMPLE/HOLD AMPLIFIER SHC9 SHC9A Monolithic SAMPLE/HOLD AMPLIFIER FEATURES -BIT THROUGHPUT ACCURACY LESS THAN µs ACQUISITION TIME WIDEBAND NOISE LESS THAN µvrms RELIABLE MONOLITHIC CONSTRUCTION Ω INPUT RESISTANCE TTL-CMOS-COMPATIBLE

More information

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com 771 Series LASER SPECTRUM ANALYZER The Power of Precision in Spectral Analysis It's Our Business to be Exact! bristol-inst.com The 771 Series Laser Spectrum Analyzer combines proven Michelson interferometer

More information

LM199/LM299/LM399/LM3999 Precision Reference

LM199/LM299/LM399/LM3999 Precision Reference Precision Reference General Description The LM199 series are precision, temperature-stabilized monolithic zeners offering temperature coefficients a factor of ten better than high quality reference zeners.

More information

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters NHST Meeting STScI - Baltimore 10 April 2003 TES & STJ Detector Summary

More information

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V

More information

Four-Channel Sample-and-Hold Amplifier AD684

Four-Channel Sample-and-Hold Amplifier AD684 a FEATURES Four Matched Sample-and-Hold Amplifiers Independent Inputs, Outputs and Control Pins 500 ns Hold Mode Settling 1 s Maximum Acquisition Time to 0.01% Low Droop Rate: 0.01 V/ s Internal Hold Capacitors

More information

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position 2 optoncdt 2401 Confocal displacement measurement system - Non-contact measurement principle

More information

stahl-electronics.com

stahl-electronics.com stahl-electronics.com PRICE LIST APRIL 2018 - MAY 2018 ( -version) countries outside EU : email to info@stahl-electronics.com Equipment for Nanoscience, Precision experiments, Cryoelectronics Contents

More information

University of Wisconsin Chemistry 524 Spectroscopic Components *

University of Wisconsin Chemistry 524 Spectroscopic Components * University of Wisconsin Chemistry 524 Spectroscopic Components * In journal articles, presentations, and textbooks, chemical instruments are often represented as block diagrams. These block diagrams highlight

More information

High Precision 2.5 V IC Reference AD580*

High Precision 2.5 V IC Reference AD580* a FEATURES Laser Trimmed to High Accuracy: 2.500 V 0.4% 3-Terminal Device: Voltage In/Voltage Out Excellent Temperature Stability: 10 ppm/ C (AD580M, U) Excellent Long-Term Stability: 250 V (25 V/Month)

More information

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model

More information

LM565/LM565C Phase Locked Loop

LM565/LM565C Phase Locked Loop LM565/LM565C Phase Locked Loop General Description The LM565 and LM565C are general purpose phase locked loops containing a stable, highly linear voltage controlled oscillator for low distortion FM demodulation,

More information

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES The current multiplication mechanism offered by dynodes makes photomultiplier tubes ideal for low-light-level measurement. As explained earlier, there

More information

Octal Sample-and-Hold with Multiplexed Input SMP18

Octal Sample-and-Hold with Multiplexed Input SMP18 a FEATURES High Speed Version of SMP Internal Hold Capacitors Low Droop Rate TTL/CMOS Compatible Logic Inputs Single or Dual Supply Operation Break-Before-Make Channel Addressing Compatible With CD Pinout

More information

PIXIS-XB: 1024BR X-RAY GROUP

PIXIS-XB: 1024BR X-RAY GROUP Now Powered by LightField The is a fully integrated camera that utilizes a back illuminated, deep depletion CCD for direct detection of X-rays between < 3keV and 20 kev. This highly sensitive, high resolution

More information

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1000A Features Linearity error maximum 1 ppm Fluxgate,

More information

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab A. Margaryan 1 Contents Introduction RF time measuring technique: Principles and experimental results of recent

More information

Agilent 86142B and 86146B Optical Spectrum Analyzers

Agilent 86142B and 86146B Optical Spectrum Analyzers Agilent 86142B and 86146B Optical Spectrum Analyzers Technical Overview Full-Feature Optical Spectrum Analyzer Exhibits excellent speed and dynamic range with convenient and powerful user interface. Filter

More information

Microscope-Spectrometer

Microscope-Spectrometer 20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments

More information

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers QE65000 Spectrometer Scientific-Grade Spectroscopy in a Small Footprint QE65000 The QE65000 Spectrometer is the most sensitive spectrometer we ve developed. Its Hamamatsu FFT-CCD detector provides 90%

More information

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER OPTICAL SPECTRUM ANALYZER MS9710B 0.6 to 1.75 µm NEW GPIB The MS9710B is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 0.6 to 1.75 µm wavelength band. In addition to uses

More information

Tunable KiloArc. Tunable Broadband Light Source.

Tunable KiloArc. Tunable Broadband Light Source. Optical Building Blocks Corporation Tunable KiloArc Tunable Broadband Light Source www.obb1.com Tunable KiloArc Need a CW laser that is tunable from 250 to 1,100 nm? yes Need it to deliver Hundreds of

More information

High specification CCD-based spectrometry for metals analysis

High specification CCD-based spectrometry for metals analysis High specification CCD-based spectrometry for metals analysis New developments in hardware and spectrum processing enable the ARL QUANTRIS CCD-based spectrometer to achieve the performance of photo-multiplier

More information

nanodpp datasheet I. FEATURES

nanodpp datasheet I. FEATURES datasheet nanodpp I. FEATURES Ultra small size high-performance Digital Pulse Processor (DPP). 16k channels utilizing smart spectrum-size technology -- all spectra are recorded and stored as 16k spectra

More information

Optional AR coating and wedge windows are available

Optional AR coating and wedge windows are available TThe PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras designed for quantitative scientific imaging optical spectroscopy applications. Designed utilizing PI s exclusive

More information

High Current High Power OPERATIONAL AMPLIFIER

High Current High Power OPERATIONAL AMPLIFIER OPA High Current High Power OPERATIONAL AMPLIFIER FEATURES WIDE SUPPLY RANGE: ±V to ±V HIGH OUTPUT CURRENT: A Peak CLASS A/B OUTPUT STAGE: Low Distortion SMALL TO- PACKAGE APPLICATIONS SERVO AMPLIFIER

More information

nanomca datasheet I. FEATURES

nanomca datasheet I. FEATURES datasheet nanomca I. FEATURES Finger-sized, high performance digital MCA. 16k channels utilizing smart spectrum-size technology -- all spectra are recorded and stored as 16k spectra with instant, distortion-free

More information

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier Model 7265 DSP Lock-in Amplifier FEATURES 0.001 Hz to 250 khz operation Voltage and current mode inputs Direct digital demodulation without down-conversion 10 µs to 100 ks output time constants Quartz

More information

Current transducer FHS 40-P/SP600

Current transducer FHS 40-P/SP600 Current transducer I PM = 0-100 A Minisens transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for

More information

MXD2125J/K. Ultra Low Cost, ±2.0 g Dual Axis Accelerometer with Digital Outputs

MXD2125J/K. Ultra Low Cost, ±2.0 g Dual Axis Accelerometer with Digital Outputs Ultra Low Cost, ±2.0 g Dual Axis Accelerometer with Digital Outputs MXD2125J/K FEATURES RoHS Compliant Dual axis accelerometer Monolithic CMOS construction On-chip mixed mode signal processing Resolution

More information

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping RIEGL LMS-Q56 high laser pulse repetition rate up to 8 khz digitization electronics for full waveform data

More information

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters General Description The LM231/LM331 family of voltage-to-frequency converters are ideally suited for use in simple low-cost circuits

More information

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications August 2003 Filter Mode Enables you to drop a single DWDM channel or measure time resolved chirp (TRC) and calculate dispersion

More information

Microprocessor-Compatible ANALOG-TO-DIGITAL CONVERTER

Microprocessor-Compatible ANALOG-TO-DIGITAL CONVERTER Microprocessor-Compatible ANALOG-TO-DIGITAL CONVERTER FEATURES COMPLETE 12-BIT A/D CONVERTER WITH REFERENCE, CLOCK, AND 8-, 12-, OR 16-BIT MICROPROCESSOR BUS INTERFACE IMPROVED PERFORMANCE SECOND SOURCE

More information

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,

More information

PUV3402 LED multiwave photometer A new approach to online process photometry

PUV3402 LED multiwave photometer A new approach to online process photometry ABB MEASUREMENT & ANALYTICS WHITE PAPER PUV3402 LED multiwave photometer A new approach to online process photometry The UV LED photometer with a design concept advantage. Measurement made easy PUV3402

More information

Reflectometer Series:

Reflectometer Series: Reflectometer Series: R54, R60 & R140 Vector Network Analyzers Clarke & Severn Electronics Ph +612 9482 1944 Email sales@clarke.com.au BUY NOW - www.cseonline.com.au KEY FEATURES Patent: US 9,291,657 No

More information

Specifications Test Conditions Vs = ± 15 V, Ta = 25 C Gain Gain Values 40, 60, 80, 100 db indicated by four LEDs Gain Accuracy ± 0.1 % (between settin

Specifications Test Conditions Vs = ± 15 V, Ta = 25 C Gain Gain Values 40, 60, 80, 100 db indicated by four LEDs Gain Accuracy ± 0.1 % (between settin Electro Optical Components, Inc. SUNSTAR 传感与控制 http://www.sensor-ic.com/ 5460 Skylane Boulevard, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Features Variable Gain 40

More information

Low-Cost, Low-Power, Low-Dropout, SOT23-3 Voltage References

Low-Cost, Low-Power, Low-Dropout, SOT23-3 Voltage References 13-1395; Rev 1; /99 Low-Cost, Low-Power, Low-Dropout, General Description The family of SOT23, low-cost series voltage references meets the cost advantage of shunt references and offers the power-saving

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

Components of Optical Instruments

Components of Optical Instruments Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors)

More information

EMC-scanner. HRE-series. See it before you CE it!

EMC-scanner. HRE-series. See it before you CE it! EMC-scanner HRE-series See it before you CE it! Print Screen image of a scan measurement. Seeing high frequencies! Now you can SEE high frequency electro magnetic fields. The background There are high

More information

taccor Optional features Overview Turn-key GHz femtosecond laser

taccor Optional features Overview Turn-key GHz femtosecond laser taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond

More information

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available. Now Powered by LightField PyLoN:2K 2048 x 512 The PyLoN :2K is a controllerless, cryogenically-cooled CCD camera designed for quantitative scientific spectroscopy applications demanding the highest possible

More information

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications System Options AC Susceptibility Magnetic Property Measurement System Many materials display dissipative mechanisms when exposed to an oscillating magnetic field, and their susceptibility is described

More information

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available. SOPHIA: 2048B The SOPHIA : 2048B camera from Princeton Instruments (PI) is fully integrated, ultra-low noise 2048 x 2048, 15 µm pixel CCD camera designed expressly for the most demanding quantitative scientific

More information

High Stability Voltage Source

High Stability Voltage Source Bilt System module - BE2100 High Stability Voltage Source Voltage to ±12V, current to ±200mA High Resolution: 21 bits, 6 ½ digits Ultra Low Noise: down to 6µVp-p Clean output noise spectrum with no spike

More information

Arbitrary power supplies. 160 W to 5200 W

Arbitrary power supplies. 160 W to 5200 W Arbitrary power supplies 160 W to 5200 W TOE 8815 Arbitrary power supplies for generation of any voltage and current characteristics with an output power from 160 W to 5200 W. With exceptionally versatile

More information

LM79XX Series 3-Terminal Negative Regulators

LM79XX Series 3-Terminal Negative Regulators 3-Terminal Negative Regulators General Description The LM79XX series of 3-terminal regulators is available with fixed output voltages of 5V, 12V, and 15V. These devices need only one external component

More information

Multiple Instrument Station Module

Multiple Instrument Station Module Multiple Instrument Station Module Digital Storage Oscilloscope Vertical Channels Sampling rate Bandwidth Coupling Input impedance Vertical sensitivity Vertical resolution Max. input voltage Horizontal

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

SPEEDBOX Technical Datasheet

SPEEDBOX Technical Datasheet SPEEDBOX Technical Datasheet Race Technology Limited, 2008 Version 1.1 1. Introduction... 3 1.1. Product Overview... 3 1.2. Applications... 3 1.3. Standard Features... 3 2. Port / Connector details...

More information

LM6118/LM6218 Fast Settling Dual Operational Amplifiers

LM6118/LM6218 Fast Settling Dual Operational Amplifiers Fast Settling Dual Operational Amplifiers General Description The LM6118/LM6218 are monolithic fast-settling unity-gain-compensated dual operational amplifiers with ±20 ma output drive capability. The

More information

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset

More information

GB4571 Video Buffer with Precision Strobed DC Restore

GB4571 Video Buffer with Precision Strobed DC Restore GB Video Buffer with Precision Strobed DC Restore DATA SHEET FEATURES DESCRIPTION accurate clamping to within ± mv less than mv clamping distortion variable clamping range ( + 3.0 V to -. V) ultra low

More information

High Speed 12-Bit Monolithic D/A Converters AD565A/AD566A

High Speed 12-Bit Monolithic D/A Converters AD565A/AD566A a FEATURES Single Chip Construction Very High Speed Settling to 1/2 AD565A: 250 ns max AD566A: 350 ns max Full-Scale Switching Time: 30 ns Guaranteed for Operation with 12 V (565A) Supplies, with 12 V

More information

LM567/LM567C Tone Decoder

LM567/LM567C Tone Decoder LM567/LM567C Tone Decoder General Description The LM567 and LM567C are general purpose tone decoders designed to provide a saturated transistor switch to ground when an input signal is present within the

More information