1 A High Eta Forward Muon Trigger & Tracking detector for CMS 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD10) 7-10 June 2010 Siena, Italy

2 A High Eta Forward Muon Trigger & Tracking detector for CMS Archana Sharma for Duccio Abbaneo, Stephane Bally, Hans Postema, Antonio Conde Garcia, Jean Paul Chatelain, Gerard Faber, Leszek Ropelewski, Serge Duarte Pinto, Marco Villa, Gabriel Croci, Matteo Alfonsi, Miranda Van Stenis, Sunil Kumar, Krishna P, Archana Sharma CERN Geneva Switzerland Stefano Bianco, Stefano Colafranceschi, Luigi Benussi, Franco Fabbri, Davide Piccolo, Giovanna Saviano LNF Frascati, Italy Nicola Turini, Eraldo Oliveri, Guido Magazzu Universita' Degli Studi di Siena INFN, Sezione di Pisa, Italy Andrey Marinov, Michael Tytgat, Nicolas Zaganidis Gent University, Gent, Belgium Marcus Hohlmann and Kondo Gnanve Dept. of Physics and Space Sciences Florida Institute of Technology Melbourne, FL USA Yong Ban, Haiyun Teng, Jingxin Cai Peking University Beijing China 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD10) 7-10 June 2010 Siena, Italy

3 Siena June

4 Initial RE system tailored to budget Reduced RE system h < 1.6 h 2.4 h=2.4 STAGED RE RE RE RE RE RE RE RE RE RE RE RE 1/1 1/2 1/3 2/1 2/2 2/3 3/1 3/2 3/3 4/1 4/2 4/3 No. of chambers 36*2 36*2 36*2 18*2 36*2 36*2 18*2 36*2 36*2 18*2 36*2 36*2 Siena June

5 Estimated Particle rates in Forward CMS RPC Region Rates Hz/cm 2 LHC (10 34 cm 2 /s) High Luminosity LHC 2.3 x LHC RB 30 Few 100 khz (tbc) RE 1, 2, 3,4 h < 1.6 Expected Charge in 10 years RE 1,2,3,4 h > 1.6 Total Expected Charge in 10 years 30 Few 100 khz (tbc) 0.05 C/cm C/cm 2 ~ C/cm 2 (10 35 cm 2 /s) Phase II SLHC?? 500Hz ~ khz Few khz Few 10s khz (0.05-1) C/cm 2 few C/cm 2 Few 10s C/cm 2 5

6 MPGDs as candidate technology Improve contribution to Muon Trigger Efficiency Combine triggering and tracking functions? Instrument the vacant (RE i/1) zone in CMS Forward 1.6 >h>2.4 6

7 MPGDs as candidate technology Enhance and optimize the readout (h-f) granularity by improved rate capability Rate capability 10 4 /mm 2 Spatial resolution ~ 100 m ( track < 45 ) Time resolution ~ 1-3 ns (Gas!) Efficiency > 98% Rate capability > 5 khz/cm 2 - Argon CO2 (non flammable mixture - big plus) 7

8 MPGDs as candidate technology Potential for going to large areas ~ 1m x 2m with industrial processes (cost effective) Long term operation experience in Compass Negligible Discharge probability with no consequence Implemented for LHCb first muon station (4m 2 ) ~ 500 khz/cm 2, operational in COMPASS for 10 years Proposed /in prep for ATLAS Muon upgrade (1000m 2 ) 8

9 CMS MPGD High Eta Feasibilty Studies - activities since August Assembly and test of two small MPGD prototypes 2. Participated in Beam tests Planned 2010 (with three different chambers) 4. Mock ups of large prototype - Size and envelope limitations - Services and routing: HV, Gas, LV, Cooling - HV Divider - 3D Model / Drawings 4. Production of the prototype 9

10 Siena June 2010

11 Siena June 2010

12 Siena June 2010

13 First Results to be studied in detail Siena June

14 Siena June 2010

15 Siena June 2010 Gabriele Croci & Michael Tytgat

16 Siena June 2010

17 Siena June 2010

18 25000 GAIN STUDIES WITH TRIPLE GEM ARGON CO2 CURRENT WITH Cu X-Rays GAIN HV Drift (Volts) Siena June

19 DISCHARGE PROBABILTY DISCHARGE STUDIES WITH TRIPLE GEM ARGON CO2 1.20E E E E E E E HV Drift (Volts) Siena June

20 RATE CAPABILITY STUDIES WITH CMS TRIPLE GEM Prototype ARGON CO GAIN E E E+06 RATE PHOTONS/mm 2 Siena June

21 Siena June 2010

22 Siena June 2010

23 Siena June 2010 CONSTRUCTION OF LARGE PROTOTYPE

24 Siena June 2010

25 Velocity field PROBLEMS.. 25 Reducing inlets diameters (1mm) the velocity field is more uniform but slower in the sector 3 and 4

26 Siena June 2010

27 Siena June

28 Siena June 2010

29 CMS Prototype GEM - Stack 29

30 CMS Prototype GEM - Stack 30

31 CMS Prototype GEM - Test Box Jean-Paul Chatelain

32 Siena June 2010 Ongoing Drift Electrode Tests

33 Current [na] All I/V scans openair2 openair1 groundedp floatingp Voltage [V] Siena June 2010

34 Honeycomb GEM studies without the honeycomb between drift and first gem 34

35 counts Analysis of GEM spectrum X displacement <adc channel> mm

36 Moving the GEM (under x rays) along x,y direction with 0,25mm steps

37 Marco Villa CMS single mask GEM1

38 TOP Single GEM Electrodes GEM 1 Top Left Bottom - Right GEM 2 GEM 3 Siena June BOTTOM

39 and cross section pictures (1) TOP Sample 1 Sample 2 Siena June BOTTOM

40 and cross section pictures (2) TOP Sample 3 Sample 4 Siena June BOTTOM

41 Drift GEM1 Anode Preparing the experimental setup 3.05 mm 2.15 mm GEM active area: 10 x 10 cm 2 Gas mixture: Ar/CO 2 70/30 Gas flow: ~ 5 l/h Water content: ~ 100 ppm H 2 O Radiation source: Cu X ray tube Siena June

42 ADC counts Taking spectra E d = 2 kv/cm 200 E i = 3 kv/cm DV GEM = 480 V 100 Rate ~ 32 Hz/mm 2 0 Energy 8.04 kev ~ 19.6 % FWHM/peak ADC channel Siena June

43 Gain Measuring the gain curve 1000 E d = 2 kv/cm E i = 3 kv/cm 100 Rate ~ 180 khz/mm 2 Spark voltage ~ 530 V Max gain ~ DV GEM [V] Siena June

44 Large GEM production by single mask method at surface treatment Workshop - CERN Serge FERRY-4/06/ Base material 50 µm polyimide foil copperclad Photoresist lamination, masking, exposure, development Chemical etching of copper Top Polyimide etching in 2 steps Electrochemical etching of copper Bot + over-etched Polyimide etching to transform hole geometry Photoresist lamination, masking, exposure, development to define electrodes Chemical etching of copper Top and Bot, Cleaning and electrical test -The LGEM are actually in step 4.

45 42cm x 990 cm Siena June

46 Chambers for June: CMS Triple GEM prototype 10 x 10 cm Honeycomb Triple GEM Single Mask GEM 1. Measure Efficiency for perpendicular tracks 2. Measure Efficiency for inclined tracks with tracking 3. Optimization of time resolution 4. Tests with Front End electronics for mips 5. Space and time resolution October 1. Gas Studies CMS High Eta Upgrade Studies Test Beam Plan Magnetic Field Operation 3. Large Prototype test Siena June

47 STATUS AND OUTLOOK 1. Prototype (standard, honeycomb, single mask) tests in lab, beam - continue 2. Beam tests 2010 continue 3. Detail mechanical design for mock up and proto ~ final 4. Definition of readout, electronics and its mechanical support - ongoing Services and routing HV, Gas, LV, cooling - ongoing 5. Mockup realization of detector Done, some details missing 6. Production of prototype expected to be completed by end of June 7. Tests of prototype 8. Feasibility / simulation studies of integration with CMS trigger and tracking to be done (not yet started) Siena June 2010

48 SPARE Siena June

49 Readout Electronics VFAT A digital on/off chip, with an adjustable threshold for each of 128 channels. Used in all the Totem detectors, the GEMs and the CSCs to simplify the DAQ and Trigger design Quarter micron CMOS technology and measures 9.43mm by 7.58mm. Trigger function to provide programmable fast OR information based on the region of the sensor hit. This can be used for the creation of a trigger. Tracking function for providing precise spatial hit information for a given triggered event. Siena June

50 Siena June

51 Siena June

52 Rate capability Measured with an X-ray (5.9 kev) tube; Ar/CO 2 /CF 4 (60/20/20) Gain of about 2x10 4 ; A very good gain stability was found up to a photon flux of about 5x10 7 Hz/cm 2 CMS high h - maximum rate LHCb meas 52

53 Triple GEM Ageing test Gain of 2x10 4 Total integrated charge of 13 C/cm 2 is expected in 10 years of operation in LHCb 50 MHz/cm 2 X-rays, in 10 days a total charge of 20 C/cm 2 was integrated; Less than 5% change in the chamber behavior CMS high h - maximum integrated charge LHCb 53

Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-η muon system

Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-η muon system This work has been submitted to the IEEE Nucl. Sci. Symp. 2011 for publication in the conference record. Copyright may be transferred without notice, after which this version may no longer be available.

More information

Performance studies of large-area triple-gem prototypes for future upgrades of the CMS forward muon system

Performance studies of large-area triple-gem prototypes for future upgrades of the CMS forward muon system Performance studies of large-area triple-gem prototypes for future upgrades of the CMS forward muon system Salvatore A. UPPUI, M. Abbrescia, A. Colaleo, G. de Robertis, F. Loddo, M. Maggi, S. Nuzzo Politecnico

More information

FIRST RESULTS OF THE RADIATION MONITORING OF THE GEM MUON DETECTORS AT CMS

FIRST RESULTS OF THE RADIATION MONITORING OF THE GEM MUON DETECTORS AT CMS FIRST RESULTS OF THE RADIATION MONITORING OF THE GEM MUON DETECTORS AT CMS L. Dimitrov 1, P. Iaydjiev 1, a, A. Marinov 1, G. Mitev 1, F. Ravotti 2, b, I. Vankov 1, c 1 Institute for Nuclear Research and

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A ] (]]]]) ]]] ]]] Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade Givi Sekhniaidze INFN sezione di Napoli On behalf of ATLAS NSW community 14th Topical Seminar on Innovative Particle

More information

Full characterization tests of Micromegas with elongated pillars

Full characterization tests of Micromegas with elongated pillars University of Würzburg Full characterization tests of Micromegas with elongated pillars B. Alvarez1 Gonzalez, L. Barak1, J. Bortfeldt1, F. Dubinin3, G. Glonti1, F. Kuger1,2, P. Iengo1, E. Oliveri1, J.

More information

Large Size GEM Detectors for 12 GeV Program in Hall A at JLab

Large Size GEM Detectors for 12 GeV Program in Hall A at JLab Large Size GEM Detectors for 12 GeV Program in Hall A at JLab Kondo GNANVO University of Virginia Gas Electron Multiplier (GEM) Detectors GEM Detectors in 12 GeV Programs in Hall A at JLab New Developments

More information

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS CR -2017/402 The Compact Muon Solenoid Experiment Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland 06 November 2017 Commissioning of the

More information

Status of UVa

Status of UVa Status of GEM-US @ UVa Kondo Gnanvo University of Virginia, Charlottesville, SoLID Collaboration Meeting @ JLab 05/15/2015 Outline GEM trackers for SoLID GEM R&D program @ UVa Plans on SoLID-GEM specific

More information

Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade

Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade Givi Sekhniaidze INFN sezione di Napoli On behalf of ATLAS NSW community 14th Topical Seminar on Innovative Particle

More information

Novel MPGD based Detectors of Single Photons for COMPASS RICH-1 Upgrade

Novel MPGD based Detectors of Single Photons for COMPASS RICH-1 Upgrade Outline Basics Why this upgrade and how R&D and Detector commissioning Results Conclusions Novel MPGD based Detectors of Single Photons for COMPASS RICH-1 Upgrade Shuddha Shankar Dasgupta INFN Sezzione

More information

Recent developments on. Micro-Pattern Gaseous Detectors

Recent developments on. Micro-Pattern Gaseous Detectors Recent developments on 0.18 mm CMOS VLSI Micro-Pattern Gaseous Detectors CMOS high density readout electronics Ions 40 % 60 % Electrons Micromegas GEM THGEM MHSP Ingrid Matteo Alfonsi (CERN) Outline Introduction

More information

GEM chambers for SoLID Nilanga Liyanage. University of Virginia

GEM chambers for SoLID Nilanga Liyanage. University of Virginia GEM chambers for SoLID Nilanga Liyanage University of Virginia Tracking needs for SoLID (PVDIS) Rate: from 100 khz to 600 khz (with baffles), GEANT3 estimation Spatial Resolution: 0.2 mm (sigma) Total

More information

Gas Electron Multiplier Detectors

Gas Electron Multiplier Detectors Muon Tomography with compact Gas Electron Multiplier Detectors Dec. Sci. Muon Summit - April 22, 2010 Marcus Hohlmann, P.I. Florida Institute of Technology, Melbourne, FL 4/22/2010 M. Hohlmann, Florida

More information

GEM beam test for the BESIII experiment

GEM beam test for the BESIII experiment RD51 week meeting CERN, Dec 09 2014 GEM beam test for the BESIII experiment Riccardo Farinelli (INFN Ferrara) a joint Kloe / BES III CGEM groups effort (INFN Ferrara, Frascati, Torino) Partially supported

More information

Introduction to TOTEM T2 DCS

Introduction to TOTEM T2 DCS Introduction to TOTEM T2 DCS Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM Single Wire Proportional Chamber Electrons liberated by ionization drift towards the anode wire. Electrical field close to the

More information

A Large Low-mass GEM Detector with Zigzag Readout for Forward Tracking at EIC

A Large Low-mass GEM Detector with Zigzag Readout for Forward Tracking at EIC MPGD 2017 Applications at future nuclear and particle physics facilities Session IV Temple University May 24, 2017 A Large Low-mass GEM Detector with Zigzag Readout for Forward Tracking at EIC Marcus Hohlmann

More information

Introduction. Planar GEM in LHCb. Cylindrical GEM for Inner Trackers

Introduction. Planar GEM in LHCb. Cylindrical GEM for Inner Trackers GEM detectors activity at the Laboratori Nazionali di Frascati INFN G.Bencivenni LNF-INFN 2 OUTLINE Introduction Planar GEM in LHCb Cylindrical GEM for Inner Trackers 3 INTRODUCTION The GEM (Gas Electron

More information

RD51 ANNUAL REPORT WG1 - Technological Aspects and Development of New Detector Structures

RD51 ANNUAL REPORT WG1 - Technological Aspects and Development of New Detector Structures RD51 ANNUAL REPORT 2009 WG1 - Technological Aspects and Development of New Detector Structures Conveners: Serge Duarte Pinto (CERN), Paul Colas (CEA Saclay) Common projects Most activities in WG1 are meetings,

More information

irpc upgrade project for CMS during HL-LHC program

irpc upgrade project for CMS during HL-LHC program irpc upgrade project for CMS during HL-LHC program 1) CMS muon spectrometer 2) irpc project 3) Team, activities, timing M. Gouzevitch (IPNL, France) and T.J Kim (Hanyang University, Korea) FJPPL/FKPPL

More information

Triple GEM detector as beam monitor Monitors for Crystal experiment at SPS A compact Time Projection chamber with GEM

Triple GEM detector as beam monitor Monitors for Crystal experiment at SPS A compact Time Projection chamber with GEM Applications with Triple GEM Detector B.Buonomo, G.Corradi, F.Murtas, G.Mazzitelli, M.Pistilli, M.Poli Lener, D.Tagnani Laboratori Nazionali di Frascati INFN P.Valente Sezione Roma INFN Triple GEM detector

More information

A spark-resistant bulk-micromegas chamber for high-rate applications

A spark-resistant bulk-micromegas chamber for high-rate applications EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN PH EP 2010 061 15 November 2010 arxiv:1011.5370v1 [physics.ins-det] 24 Nov 2010 A spark-resistant bulk-micromegas chamber for high-rate applications Abstract

More information

Recent Developments in Gaseous Tracking Detectors

Recent Developments in Gaseous Tracking Detectors Recent Developments in Gaseous Tracking Detectors Stefan Roth RWTH Aachen 1 Outline: 1. Micro pattern gas detectors (MPGD) 2. Triple GEM detector for LHC-B 3. A TPC for TESLA 2 Micro Strip Gas Chamber

More information

The trigger system of the muon spectrometer of the ALICE experiment at the LHC

The trigger system of the muon spectrometer of the ALICE experiment at the LHC The trigger system of the muon spectrometer of the ALICE experiment at the LHC Francesco Bossù for the ALICE collaboration University and INFN of Turin Siena, 09 June 2010 Outline 1 Introduction 2 Muon

More information

Aging measurements with the Gas Electron Multiplier (GEM)

Aging measurements with the Gas Electron Multiplier (GEM) 1 Aging measurements with the Gas Electron Multiplier (GEM) M.C. Altunbas a, K. Dehmelt b S. Kappler c,d,, B. Ketzer c, L. Ropelewski c, F. Sauli c, F. Simon e a State University of New York, Buffalo,

More information

Small-pad Resistive Micromegas for Operation at Very High Rates. M. Alviggi, M.T. Camerlingo, V. Canale, M. Della Pietra, C. Di Donato, C.

Small-pad Resistive Micromegas for Operation at Very High Rates. M. Alviggi, M.T. Camerlingo, V. Canale, M. Della Pietra, C. Di Donato, C. Small-pad Resistive Micromegas for Operation at Very High Rates CERN; E-mail: paolo.iengo@cern.ch M. Alviggi, M.T. Camerlingo, V. Canale, M. Della Pietra, C. Di Donato, C. Grieco University of Naples and

More information

DEVELOPMENT OF LARGE SIZE MICROMEGAS DETECTORS

DEVELOPMENT OF LARGE SIZE MICROMEGAS DETECTORS DEVELOPMENT OF LARGE SIZE MICROMEGAS DETECTORS Paolo Iengo LAPP/CNRS Outline 2 Introduction on gaseous detectors Limits on rate capability Micro Pattern Gaseous Detector & Micromegas ATLAS & the LHC upgrade

More information

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators Grant Agreement No: 654168 AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators Horizon 2020 Research Infrastructures project AIDA -2020 MILESTONE REPORT SMALL-SIZE PROTOTYPE OF THE

More information

THE MULTIWIRE CHAMBER REVOLUTION (Georges Charpak, 1968)

THE MULTIWIRE CHAMBER REVOLUTION (Georges Charpak, 1968) 1 THE MULTIWIRE CHAMBER REVOLUTION (Georges Charpak, 1968) 2 ARRAY OF THIN ANODE WIRES BETWEEN TWO CATHODES LARGE MWPC SPLIT FIELD MAGNET DETECTOR (CERN ISR, 1972) G. Charpak et al, Nucl. Instr. and Meth.

More information

TPC Readout with GEMs & Pixels

TPC Readout with GEMs & Pixels TPC Readout with GEMs & Pixels + Linear Collider Tracking Directional Dark Matter Detection Directional Neutron Spectroscopy? Sven Vahsen Lawrence Berkeley Lab Cygnus 2009, Cambridge Massachusetts 2 Our

More information

Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1 upgrade of the Muon Spectrometer

Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1 upgrade of the Muon Spectrometer Advancements in Nuclear Instrumenta2on Measurement Methods and their Applica2ons 20-24 April 2015, Lisbon Congress Center Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1

More information

MPGDs: a tool for progress in HEP

MPGDs: a tool for progress in HEP MPGDs: a tool for progress in HEP S. Dalla Torre 1 OUTLOOK Introduction: facts about MPGDs APPLICATIONS The overall application panorama (non an exhaustive list) Selected examples Large tracking systems

More information

Phase 1 upgrade of the CMS pixel detector

Phase 1 upgrade of the CMS pixel detector Phase 1 upgrade of the CMS pixel detector, INFN & University of Perugia, On behalf of the CMS Collaboration. IPRD conference, Siena, Italy. Oct 05, 2016 1 Outline The performance of the present CMS pixel

More information

Tracking properties of the two-stage GEM/Micro-groove detector

Tracking properties of the two-stage GEM/Micro-groove detector Nuclear Instruments and Methods in Physics Research A 454 (2000) 315}321 Tracking properties of the two-stage GEM/Micro-groove detector A. Bondar, A. Buzulutskov, L. Shekhtman *, A. Sokolov, A. Tatarinov,

More information

The detection of single electrons using the MediPix2/Micromegas assembly as Direct Pixel Segmented Anode

The detection of single electrons using the MediPix2/Micromegas assembly as Direct Pixel Segmented Anode The detection of single electrons using the MediPix2/Micromegas assembly as Direct Pixel Segmented Anode NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan

More information

Development and tests of a large area CsI-TGEM-based RICH prototype

Development and tests of a large area CsI-TGEM-based RICH prototype Development and tests of a large area CsI-TGEM-based RICH prototype G. Bencze 1,2, A. Di Mauro 1, P. Martinengo 1, L. Mornar 1, D. Mayani Paras 3, E. Nappi 4, G. Paic 1,3, V. Peskov 1,3 1 CERN, Geneva,

More information

2 Aging Phenomena in Gaseous Detectors (DESY, Oct. 2001), submitted to ELSEVIER PREPRINT Figure 1. Electron microscope photograph of a GEM foil with s

2 Aging Phenomena in Gaseous Detectors (DESY, Oct. 2001), submitted to ELSEVIER PREPRINT Figure 1. Electron microscope photograph of a GEM foil with s Aging Phenomena in Gaseous Detectors (DESY, Oct. 2001), submitted to ELSEVIER PREPRINT 1 Aging Measurements with the Gas Electron Multiplier (GEM) M.C. Altunbas a, K. Dehmelt b S. Kappler cdλ, B. Ketzer

More information

THE ATLAS experiment was designed for a wide physics

THE ATLAS experiment was designed for a wide physics The Micromegas Project for the ATLAS Upgrade Theodoros Alexopoulos, on behalf of the MAMMA R&D Collaboration Abstract Micromegas is one of the detector technologies (along with small-gap Thin Gap Chambers)

More information

arxiv: v1 [physics.ins-det] 25 Oct 2012

arxiv: v1 [physics.ins-det] 25 Oct 2012 The RPC-based proposal for the ATLAS forward muon trigger upgrade in view of super-lhc arxiv:1210.6728v1 [physics.ins-det] 25 Oct 2012 University of Michigan, Ann Arbor, MI, 48109 On behalf of the ATLAS

More information

Tracking and Alignment in the CMS detector

Tracking and Alignment in the CMS detector Tracking and Alignment in the CMS detector Frédéric Ronga (CERN PH-CMG) for the CMS collaboration 10th Topical Seminar on Innovative Particle and Radiation Detectors Siena, October 1 5 2006 Contents 1

More information

GEM Detectors for COMPASS

GEM Detectors for COMPASS IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 48, NO. 4, AUGUST 2001 1065 GEM Detectors for COMPASS B. Ketzer, S. Bachmann, M. Capeáns, M. Deutel, J. Friedrich, S. Kappler, I. Konorov, S. Paul, A. Placci,

More information

The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO)

The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO) The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO) A. Ansarinejad1,2, A. Attili1, F. Bourhaleb2,R. Cirio1,2,M. Donetti1,3, M. A. Garella1, S. Giordanengo1,

More information

Measurements With Irradiated 3D Silicon Strip Detectors

Measurements With Irradiated 3D Silicon Strip Detectors Measurements With Irradiated 3D Silicon Strip Detectors Michael Köhler, Michael Breindl, Karls Jakobs, Ulrich Parzefall, Liv Wiik University of Freiburg Celeste Fleta, Manuel Lozano, Giulio Pellegrini

More information

The CMS Muon Detector

The CMS Muon Detector VCI 21 conference 19-23/2/21 The CMS Muon Detector Paolo Giacomelli INFN Sezione di Bologna Univ. of California, Riverside General Overview Drift Tubes Cathode Strip Chambers Resistive Plate Chambers Global

More information

The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem The MUSE experiment Technical Overview Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem MUSE is not your garden variety scattering experiment Low beam flux Large angle, non-magnetic

More information

Uva GEM R&D Update. Nilanga Liyanage

Uva GEM R&D Update. Nilanga Liyanage Uva GEM R&D Update Nilanga Liyanage Our Class 1000 Clean Room GEM Lab @ UVa Current Clean Room (3.5 3 m 2 ) Built originally for the BigBite drift chambers construction Located in a large (4.5 m x 9 m)

More information

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8 Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8 1 Institite of Physics, Academia Sinica 128 Sec. 2, Academia Rd., Nankang, Taipei 11529, Taiwan cyhsieh0531@gmail.com

More information

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade Silicon Sensor and Detector Developments for the CMS Tracker Upgrade Università degli Studi di Firenze and INFN Sezione di Firenze E-mail: candi@fi.infn.it CMS has started a campaign to identify the future

More information

arxiv: v1 [physics.ins-det] 3 Jun 2015

arxiv: v1 [physics.ins-det] 3 Jun 2015 arxiv:1506.01164v1 [physics.ins-det] 3 Jun 2015 Development and Study of a Micromegas Pad-Detector for High Rate Applications T.H. Lin, A. Düdder, M. Schott 1, C. Valderanis a a Johannes Gutenberg-University,

More information

CMS RPC HL-LHC upgrade with fast timing detectors

CMS RPC HL-LHC upgrade with fast timing detectors Maxime Gouzevitch CMS RPC HL-LHC upgrade with fast timing detectors on behalf of the CMS MUON group ICHEP, SEOUL, 2018 1) RPC upgrade project and motivation 2-3) Requirements and design 4-7) Validation

More information

Development of Floating Strip Micromegas Detectors

Development of Floating Strip Micromegas Detectors Development of Floating Strip Micromegas Detectors Jona Bortfeldt LS Schaile Ludwig-Maximilians-Universität München Science Week, Excellence Cluster Universe December 2 nd 214 Introduction Why Detector

More information

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS NOTE 1998/065 The Compact Muon Solenoid Experiment CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland 21-st Oct 1998 Results of tests of Inverted

More information

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Takeshi Fujiwara 1, Yuki Mitsuya 2, Hiroyuki Takahashi 2, and Hiroyuki Toyokawa 2 1 National Institute of Advanced Industrial

More information

CALICE AHCAL overview

CALICE AHCAL overview International Workshop on the High Energy Circular Electron-Positron Collider in 2018 CALICE AHCAL overview Yong Liu (IHEP), on behalf of the CALICE collaboration Nov. 13, 2018 CALICE-AHCAL Progress, CEPC

More information

Design and Construction of a cylindrical GEM detector as the Inner Tracker device of the KLOE-2 experiment

Design and Construction of a cylindrical GEM detector as the Inner Tracker device of the KLOE-2 experiment Design and Construction of a cylindrical GEM detector as the Inner Tracker device of the KLOE-2 experiment G. Morello LNF-INFN, Frascati, Italy E-mail: morello@lnf.infn.it A. Balla, G. Bencivenni, S. Cerioni,

More information

Average energy lost per unit distance traveled by a fast moving charged particle is given by the Bethe-Bloch function

Average energy lost per unit distance traveled by a fast moving charged particle is given by the Bethe-Bloch function Average energy lost per unit distance traveled by a fast moving charged particle is given by the Bethe-Bloch function This energy loss distribution is fit with an asymmetric exponential function referred

More information

UniTO - PROPOSAL PhD programme in_physics HR-MPGD-4-NG-HEP

UniTO - PROPOSAL PhD programme in_physics HR-MPGD-4-NG-HEP UniTO - PROPOSAL PhD programme in_physics HR-MPGD-4-NG-HEP Scientific Project Proposal The PhD Doctoral School in Physics of the University of Turin can host a three-year doctoral programme aimed to develop

More information

Construction and first beam-tests of silicon-tungsten prototype modules for the CMS High Granularity Calorimeter for HL-LHC

Construction and first beam-tests of silicon-tungsten prototype modules for the CMS High Granularity Calorimeter for HL-LHC TIPP - 22-26 May 2017, Beijing Construction and first beam-tests of silicon-tungsten prototype modules for the CMS High Granularity Calorimeter for HL-LHC Francesco Romeo On behalf of the CMS collaboration

More information

Production of HPDs for the LHCb RICH Detectors

Production of HPDs for the LHCb RICH Detectors Production of HPDs for the LHCb RICH Detectors LHCb RICH Detectors Hybrid Photon Detector Production Photo Detector Test Facilities Test Results Conclusions IEEE Nuclear Science Symposium Wyndham, 24 th

More information

Micromegas for muography, the Annecy station and detectors

Micromegas for muography, the Annecy station and detectors Micromegas for muography, the Annecy station and detectors M. Chefdeville, C. Drancourt, C. Goy, J. Jacquemier, Y. Karyotakis, G. Vouters 21/12/2015, Arche meeting, AUTH Overview The station Technical

More information

What do the experiments want?

What do the experiments want? What do the experiments want? prepared by N. Hessey, J. Nash, M.Nessi, W.Rieger, W. Witzeling LHC Performance Workshop, Session 9 -Chamonix 2010 slhcas a luminosity upgrade The physics potential will be

More information

Operation and performance of the CMS Resistive Plate Chambers during LHC run II

Operation and performance of the CMS Resistive Plate Chambers during LHC run II Operation and performance of the CMS Resistive Plate Chambers during LHC run II, Isabel Pedraza Benemérita Universidad Autónoma de Puebla On behalf of the CMS collaboration XXXI Reunión Anual de la División

More information

Study of gain fluctuations with InGrid and TimePix

Study of gain fluctuations with InGrid and TimePix Study of gain fluctuations with InGrid and TimePix Michael Lupberger 5th RD51 Collaboration Meeting 24-27 May 2010 Freiburg, Germany Summary Hardware Timepix Chip + InGrid Experimental setup and calibration

More information

Micromegas calorimetry R&D

Micromegas calorimetry R&D Micromegas calorimetry R&D June 1, 214 The Micromegas R&D pursued at LAPP is primarily intended for Particle Flow calorimetry at future linear colliders. It focuses on hadron calorimetry with large-area

More information

Gas Detectors for μ systems

Gas Detectors for μ systems Gas Detectors for μ systems Marcello Piccolo SNOWMASS August 2005 μ system requirements for gaseous detectors Given the design we have seen up to now, a muon system should comprise a detector that; Is

More information

Status of the LHCb Experiment

Status of the LHCb Experiment Status of the LHCb Experiment Werner Witzeling CERN, Geneva, Switzerland On behalf of the LHCb Collaboration Introduction The LHCb experiment aims to investigate CP violation in the B meson decays at LHC

More information

Pixel hybrid photon detectors

Pixel hybrid photon detectors Pixel hybrid photon detectors for the LHCb-RICH system Ken Wyllie On behalf of the LHCb-RICH group CERN, Geneva, Switzerland 1 Outline of the talk Introduction The LHCb detector The RICH 2 counter Overall

More information

VErtex LOcator (VELO)

VErtex LOcator (VELO) Commissioning the LHCb VErtex LOcator (VELO) Mark Tobin University of Liverpool On behalf of the LHCb VELO group 1 Overview Introduction LHCb experiment. The Vertex Locator (VELO). Description of System.

More information

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration R&D Plans, Present Status and Perspectives Benedikt Vormwald Hamburg University on behalf of the CMS collaboration EPS-HEP 2015 Vienna, 22.-29.07.2015 CMS Tracker Upgrade Program LHC HL-LHC ECM[TeV] 7-8

More information

Spectrometer cavern background

Spectrometer cavern background ATLAS ATLAS Muon Muon Spectrometer Spectrometer cavern cavern background background LPCC Simulation Workshop 19 March 2014 Jochen Meyer (CERN) for the ATLAS Collaboration Outline ATLAS Muon Spectrometer

More information

The CMS Outer HCAL SiPM Upgrade.

The CMS Outer HCAL SiPM Upgrade. The CMS Outer HCAL SiPM Upgrade. Artur Lobanov on behalf of the CMS collaboration DESY Hamburg CALOR 2014, Gießen, 7th April 2014 Outline > CMS Hadron Outer Calorimeter > Commissioning > Cosmic data Artur

More information

X-ray Scanners* for ATLAS Barrel TRT Modules

X-ray Scanners* for ATLAS Barrel TRT Modules X-ray Scanners* for ATLAS Barrel TRT Modules ** Hampton University * This work was funded by the National Science Foundation Award No. 0072686 ** On the behalf of ATLAS TRT Collaboration 1 Abstract X-ray

More information

Performance of 8-stage Multianode Photomultipliers

Performance of 8-stage Multianode Photomultipliers Performance of 8-stage Multianode Photomultipliers Introduction requirements by LHCb MaPMT characteristics System integration Test beam and Lab results Conclusions MaPMT Beetle1.2 9 th Topical Seminar

More information

GEM chambers for SoLID Nilanga Liyanage. University of Virginia

GEM chambers for SoLID Nilanga Liyanage. University of Virginia GEM chambers for SoLID Nilanga Liyanage University of Virginia SoLID Spectrometer Gas Cerenkov Shashlyk Baffles GEM s 2 Main Challenge: large area COMPASS GEM chambers only 30 cm x 30 cm; there were total

More information

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration The LHCb Upgrade BEACH 2014 XI International Conference on Hyperons, Charm and Beauty Hadrons! University of Birmingham, UK 21-26 July 2014 Simon Akar on behalf of the LHCb collaboration Outline The LHCb

More information

Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8

Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8 Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8 1 Department of physics, Kyoto University Kitashirakawa-Oiwakecho, Sakyo-ku, Kyoto 606-8502, Japan E-mail: natsuki@scphys.kyoto-u.ac.jp

More information

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics How to compose a very very large jigsaw-puzzle CMS ECAL Sept. 17th, 2008 Nicolo Cartiglia, INFN, Turin,

More information

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades for High Luminosity LHC Upgrades R. Carney, K. Dunne, *, D. Gnani, T. Heim, V. Wallangen Lawrence Berkeley National Lab., Berkeley, USA e-mail: mgarcia-sciveres@lbl.gov A. Mekkaoui Fermilab, Batavia, USA

More information

Parallel Ionization Multiplier(PIM) : a new concept of gaseous detector for radiation detection improvement

Parallel Ionization Multiplier(PIM) : a new concept of gaseous detector for radiation detection improvement Parallel Ionization Multiplier(PIM) : a new concept of gaseous detector for radiation detection improvement D. Charrier, G. Charpak, P. Coulon, P. Deray, C. Drancourt, M. Legay, S. Lupone, L. Luquin, G.

More information

The Detector at the CEPC: Calorimeters

The Detector at the CEPC: Calorimeters The Detector at the CEPC: Calorimeters Tao Hu (IHEP) and Haijun Yang (SJTU) (on behalf of the CEPC-SppC Study Group) IHEP, Beijing, March 11, 2015 Introduction Calorimeters Outline ECAL with Silicon and

More information

Solid Instrumentation and GEM chambers Nilanga Liyanage. University of Virginia

Solid Instrumentation and GEM chambers Nilanga Liyanage. University of Virginia Solid Instrumentation and GEM chambers Nilanga Liyanage University of Virginia SoLID Spectrometer Gas Cerenkov Shashlyk Baffles GEM s 2 SoLID Spectrometer for SIDIS Gas Electron Multiplier- GEM: technology

More information

Effects of the induction-gap parameters on the signal in a double-gem detector

Effects of the induction-gap parameters on the signal in a double-gem detector WIS/27/02-July-DPP Effects of the induction-gap parameters on the signal in a double-gem detector G. Guedes 1, A. Breskin, R. Chechik *, D. Mörmann Department of Particle Physics Weizmann Institute of

More information

Status of the Continuous Ion Back Flow Module for TPC Detector

Status of the Continuous Ion Back Flow Module for TPC Detector Status of the Continuous Ion Back Flow Module for TPC Detector Huirong QI Institute of High Energy Physics, CAS August 25 th, 2016, USTC, Heifei - 1 - Outline Motivation and goals Hybrid Gaseous Detector

More information

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data

Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data Development of a Highly Selective First-Level Muon Trigger for ATLAS at HL-LHC Exploiting Precision Muon Drift-Tube Data S. Abovyan, V. Danielyan, M. Fras, P. Gadow, O. Kortner, S. Kortner, H. Kroha, F.

More information

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group The LHCb Vertex Locator : status and future perspectives Marina Artuso, Syracuse University for the VELO Group The LHCb Detector Mission: Expore interference of virtual new physics particle in the decays

More information

A triple GEM detector with two dimensional readout

A triple GEM detector with two dimensional readout A triple GEM detector with two dimensional readout M. Ziegler, P. Sievers, U. Straumann Physik Institut Universität Zürich arxiv:hep-ex/77v1 4 Jul 2 February 7, 28 This is a reduced version for hep-ex,

More information

Test of a MWPC for the LHCb Muon System at the Gamma Irradiation Facility at CERN

Test of a MWPC for the LHCb Muon System at the Gamma Irradiation Facility at CERN Test of a MWPC for the LHCb Muon System at the Gamma Irradiation Facility at CERN LHCb-MUON 2005-003 12 January 2005 M. Anelli, P. Ciambrone, G. Felici, C. Forti, G. Lanfranchi, R. Rosellini, M. Santoni,

More information

Large TPC Prototype of LCTPC

Large TPC Prototype of LCTPC Large TPC Prototype of LCTPC Klaus Dehmelt DESY On behalf of the LCTPC Collaboration LCWS2010 Beijing, China LCTPC Collaboration 2 LCTPC Collaboration Performance goals and design parameters for a TPC

More information

PoS(TIPP2014)065. The Triple-GEM Project for the Phase 2 Upgrade of the CMS Muon System

PoS(TIPP2014)065. The Triple-GEM Project for the Phase 2 Upgrade of the CMS Muon System The Triple-GEM Project for the Phase 2 Upgrade of the CMS Muon System D. Abbaneo 15, M. Abbas 15, M. Abbrescia 2, A.A. Abdelalim 8, M. Abi Akl 13, W. Ahmed 8, W. Ahmed 17, P. Altieri 2, R. Aly 8, A. Ashfaq

More information

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration ATLAS Muon Trigger and Readout Considerations Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration ECFA High Luminosity LHC Experiments Workshop - 2016 ATLAS Muon System Overview

More information

Discharge Investigation in GEM Detectors in the CMS Experiment

Discharge Investigation in GEM Detectors in the CMS Experiment Discharge Investigation in GEM Detectors in the CMS Experiment Jonathan Corbett August 24, 2018 Abstract The Endcap Muon detectors in the CMS experiment are GEM detectors which are known to have occasional

More information

Development of High Granulated Straw Chambers of Large Sizes

Development of High Granulated Straw Chambers of Large Sizes Development of High Granulated Straw Chambers of Large Sizes V.Davkov 1, K.Davkov 1, V.V.Myalkovskiy 1, L.Naumann 2, V.D.Peshekhonov 1, A.A.Savenkov 1, K.S.Viryasov 1, I.A.Zhukov 1 1 ) Joint Institute

More information

arxiv: v1 [physics.ins-det] 13 Jul 2018

arxiv: v1 [physics.ins-det] 13 Jul 2018 A new type of RPC with very low resistive material S. Chakraborty a, S. Chatterjee a, S. Roy a,, A. Roy b, S. Biswas a,, S. Das a, S. K. Ghosh a, S. K. Prasad a, S. Raha a arxiv:1807.04984v1 [physics.ins-det]

More information

A New GEM Module for the LPTPC. By Stefano Caiazza

A New GEM Module for the LPTPC. By Stefano Caiazza A New GEM Module for the LPTPC By Stefano Caiazza Basics The TPC Gas Tight Container where ionization occurs Well known Electric and Magnetic Fields To control the drifting inside the chamber The most

More information

Status of the Continuous Ion Back Flow Module for CEPC-TPC

Status of the Continuous Ion Back Flow Module for CEPC-TPC Status of the Continuous Ion Back Flow Module for CEPC-TPC Huirong QI Institute of High Energy Physics, CAS September 1 st, 2016, TPC Tracker Detector Technology mini-workshop, IHEP - 1 - Outline Motivation

More information

PandaX-III High Pressure Gas TPC and its Prototype

PandaX-III High Pressure Gas TPC and its Prototype PandaX-III High Pressure Gas TPC and its Prototype Ke HAN ( 韩柯 ) Shanghai Jiao Tong University On Behalf of the PandaX-III Collaboration May 25, 2017 Outline PandaX-III project overview Design features

More information

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol University of Bristol E-mail: sophie.richards@bristol.ac.uk The upgrade of the LHCb experiment is planned for beginning of 2019 unitl the end of 2020. It will transform the experiment to a trigger-less

More information

Gas Pixel Detectors. Ronaldo Bellazzini INFN - Pisa. 8th International Workshop on Radiation Imaging Detectors (IWORID-8) Pisa 2-6/july 2

Gas Pixel Detectors. Ronaldo Bellazzini INFN - Pisa. 8th International Workshop on Radiation Imaging Detectors (IWORID-8) Pisa 2-6/july 2 Gas Pixel Detectors Ronaldo Bellazzini INFN - Pisa 8th International Workshop on Radiation Imaging Detectors (IWORID-8) Pisa 2-6/july 2 2006 Polarimetry: The Missing Piece of the Puzzle Imaging: Chandra

More information

Development, Characterization and Qualification of first GEM foils produced in India

Development, Characterization and Qualification of first GEM foils produced in India arxiv:83.36v [physics.ins-det] 8 Mar 8 Development, Characterization and Qualification of first GEM foils produced in India Aashaq Shah, Asar Ahmed, Mohit Gola, Ram krishna Sharma, Shivali Malhotra, Ashok

More information

New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic

New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic Outline Short history of MAPS development at IPHC Results from TowerJazz CIS test sensor Ultra-thin

More information