LED Medical Lighting

Size: px
Start display at page:

Download "LED Medical Lighting"

Transcription

1 Since 1895 Bulletin 16MED Lighting Innovators LED Medical Lighting Patient & Facility Featuring: OPTeCOLOR (95+ CRI) LED,, IP65, Cleanroom

2 ISO 5 CLEANROOM ISO 5 CLEANROOM SEARCH BY DESIGN AND APPLICATION Page 2 Section Application / Design Page Kirlin Expertise and Dependability Since Section I SmartLED MRI Introduction and Section Table of Contents 6-9 SmartLED MRI Lighting Systems Downlight and Sconce Lighting Systems: 1. Luminaires 2. Driver 3. Filter Downlight, Adjustable and Wall Wash Luminaires Sconces (ADA Compliant) and Luminaire Options 14 Remote Driver (Required) RFI/EMI Filter (Required) 15 Emergency Power Supply (Optional) Room Configurations, Wiring Diagrams Downlighting Design Guide and Checklist 20 Scenic Panel (2 x 2 Configurable) Systems: Scenic Panel Luminaires 2. Driver Remote Driver (Required) 3. Filter RFI/EMI Filter (Required) 24 Room Configuration, Checklist, Wiring Diagrams Section II Patient Exam Introduction and Section Table of Contents Lensed Antimicrobial Trim Level 1 Infection Control 30 Patient Exam IP65 Rated, ; Tamper Resistant Level 2 and Level 2 + Infection Control IP65 VR 31 Class 100 Cleanroom; Tamper Resistant Level 3 and Level 3 + Infection Control 100 IP65 VR 32 Patient Exam Performance, Typical Installations, Options and Ordering Section III Motorized Patient Exam Introduction and Section Table of Contents OB and LDRP INFRALED 60: Fully Recessed with Remote Control & Wall Control Motorized Patient Exam ICU, CCU, PICU, NICU, ED, Cath Lab, OR (With Remote & Wall Controls) INFRALED : Fully Recessed with Remote Control & Wall Control Patient Room, Pathology OPTeLED : Fully Recessed with Wall Control Section IV Showerlights Introduction and Section Table of Contents Gasketed Flare Trim - Non-Conductive Showerlights: Dead Front (Non-Conductive) IP65 Rated and Tamper Resistant Trim - Non-Conductive Super Shallow Housing and Gasketed Trim - Non-Conductive Gasketed Drop Polycarbonate Trim - Non-Conductive Showerlight Options and Ordering Section V General Lighting and Clinical Spaces Introduction and Section Table of Contents Downlight, Wall Wash and Super Shallow Round and Square General Lighting IP65 Rated, ; Tamper Resistant Level 2 and Level 2 + Infection Control IP65 Clinical Spaces VR Class 100 Cleanroom Sealed Fixture Level 3 Infection Control, Sealed Fixture, IP General Lighting and Clinical Space Options and Ordering 53 Section VI Nightlights, Steplights and Chart Lights Introduction and Section Table of Contents Nightlights Inconspicuous (Round, Square, Rectangle) and Brick Light 56 Nightlights, Steplights Single and Double Face and Chart Lights Maximum Security 57 Steplights and Chart Lights Inconspicuous (Round, Square, Rectangle) and Brick Light 58 Nightlight, Steplight and Chart Light Options and Ordering 59 LUMINAIRE NUMBERING LOGIC MRR L K-MFL Series M = Medical Mount R = Recessed S = Surface N = Nightlight Shape/Design R = Round S = Square T = Rectangle V = Vandal P = Panel (Scenic) Size Recessed Aperture Surface Diameter Voltage Must Specify Lumen Series Must Specify Sequence in Catalog CLASS CLASS Options

3 SEARCH BY NUMBER (SORTED ALPHABETICALLY) Product # Description Pg Product # Description Pg Product # Description Pg EMI MRI Backup Power 15 MRR L MRR L 51 MRI 11 Exam Backup Power 35 MRR L MRR L LPS-0700A MRI Driver For Panels 24 MRR L MRR L Patient Room 52 LPS-1220A MRI Driver For Lights 15 MRR L MRI 12 MRR L MNR Nightlight 56 MRR L MRR Motorized Exam 40 MNR Steplight/Chart Light 58 MRR L MRR INFRALED MRI 13 MNS Nightlight 56 MRR L MRR Motorized Exam 42 MNS Steplight/Chart Light 58 MRR L MRR OPTeLED MNT MRR L Nightlight 56 Shower 46 MRS L MRI 11 MNT MRR L MRS L MNT MRR L MRS L Steplight/Chart Light 58 MNT MRR L MRS L Patient Room 50 MNT MRR L MRS L MNT Nightlight 57 MRR L Patient Room 50 MRS L MNV MRR L MRS L MRP MRI Scenic Panel 21 MRR L MRS L MRI 13 MRR L MRR L MRS INFRALED MRR L MRI 10 MRR L Patient Room 51 MRT L MRR L MRR L MRT L Patient Exam 30 MRR L MRR L MRI 11 MRT L MRR L Shower 46 MRR L MRV L Patient Exam 32 MRR L MRR L MRV L Patient Exam 30 MRR L MRR L MRV L Shower 46 MRR L MRR L MRV L MRR L MRR L Patient Exam 32 MRV L Patient Room 52 MRR L MRR L Patient Room 51 MRV L Patient Room 50 MRR L MRR L Patient Room 52 MRV L Patient Exam 31 MRR L MRR L MRI 13 MRV L MRR L MRR L MRV L MRR L MRR L MRV L Patient Exam 31 MRR L Patient Room 51 MRR L MRV L Patient Exam 32 MRR L MRR L MRV L MRR L Shower 46 MRR L MRV L Patient Room 52 MRR L MRR L MRV L Patient Exam 32 MRR L MRR L MSR L Shower 47 MRI Cylinder 13 MRR L MRR L MSR MRI Sconce 14 Patient Room 51 MRR L Patient Room 51 MRR L RFI-3100D MRI Filter 15,24 MRR L MRR L MSS MRR L MRI 10 MAGNIFYING GLASS ICON (FOUND THROUGHOUT CATALOG) INDICATES TABLE OF CONTENTS PLEASE VISIT FOR: KIRLIN MEDICAL LIGHTING PRODUCTS WITH OTHER LIGHT SOURCES IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC) AND KIRLIN S COMPLETE COLLECTION OF LED LUMINAIRES IN KIRLIN S LATITUDES LED LIGHTING CATALOG (BULLETIN 15/16LED). Page 3

4 KIRLIN EXPERTISE AND DEPENDABILITY SINCE 1895 A SAFER ENVIRONMENT FOR PATIENTS AND STAFF Fully recessed fixtures provide an open work space. ISO 5 Class 100 sealed housings and IP65 trims provide optimal protection against pathogen transmission through luminaires. antimicrobial trim finish inhibits survival of pathogens. Compact and smooth trims, lenses and controls are easy to clean and disinfect. Dead-front (non-conductive) shower trims protect patients and staff. Attractive, inconspicuous vandal resistant designs ideal for ED, psychiatric units and public spaces. CLASS IP 65 ISO CLEANROOM KIRLIN OPTeCOLOR LED HIGHER QUALITY LIGHT FOR MORE ACCURATE DIAGNOSIS AND IMPROVED VISUAL ACUITY High color rendering LEDs assure accurate tissue color rendering: 95+ CRI with excellent R9 (Red), R13 and R15 (Skin Colors) Ideal color temperatures for specific tasks: 3500K (Neutral white: Standard), 3000K (Warm white: Option -30K), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K). Up to 9000 footcandles are provided for the most demanding and intricate medical procedures. -SPT, -NFL, -MFL and -WFL distributions available. Common CRI High CRI GREATER CONTROL FOR IMPROVED CARE Kirlin delivers dimmable light from multiple sources, at proper angles, with optimal light levels to reduce shadows and illuminate clinicians line of site. Intuitive and responsive controls for our motorized lighting systems provide quick and accurate adjustment of direction and intensity of the light. Dimming down to 10% (and 0.2% for MRI lighting systems) permits staff to finely tune light levels for specific tasks, each clinician and time of day. SmartSupply MRI lighting system remote driver controls up to twelve fixtures with 3 zones of dimming. Page 4

5 KIRLIN EXPERTISE AND DEPENDABILITY SINCE 1895 GREATER COMFORT FOR PATIENT AND STAFF LED does not project heat toward the room environment, assuring patient and practitioner comfort while avoiding tissue desiccation. SmartLED Scenic Panels create a soothing, attractive, and more natural environment to reduce patient stress, promoting the healing process. Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; motorized lighting systems controls do not invade patient s personal space. INFRALED Series remote controls use invisible infrared signals to prevent unintended consequences, such as migraines and photosensitive epileptic seizures. Red/Amber (Option -RA) nightlights maintain patients melatonin levels and proper circadian rhythm, ensuring restful nights and time for healing. REDUCED OPERATING COSTS ARRA QUALIFIED Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. Corrosion resistant all-aluminum construction extends every components life by 50% due to operating 25% cooler. Power consumption is typically only 20% of traditional light sources. Fully sustainable. Modular, internal components are visible and easily accessed through the aperture of the fixture. Lighthead may be inexpensively updated to change spacing criteria, light level and color temperature. Luminaires are designed for multiple lumen packages, allowing the specifier to select the most energy efficient solution for each application. LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. Shallow and super shallow recessed housings fit easily in crowded plenums. Page 5

6 SECTION I: SmartLED MRI - THE TURNKEY KIRLIN SYSTEM SmartLED NON FERROMAGNETIC LUMINAIRES Award winning 1500 lumen and 2500 lumen ambient downlights, adjustable task lighting and wall washes. Wall sconces and surface mount available. Up to 4 spacing criteria available: From 0.3 (SPT) for task lighting to 1.5 (WFL) for ambient lighting Architectural SSL Product Innovation Award SmartLED SCENIC PANELS Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. Creates a calming environment to reduce patient stress and assist in the healing process. Limitless configurations available to maximize impact and match the unique dimensions of each suite. SmartSupply REMOTE DRIVER 2011 IES Progress Report Selections Controls up to twelve fixtures (1500L Series) or twelve Scenic Panels or six fixtures (2500L Series). Dims to 0.2% permitting finely tuned light levels. 3 zones of dimming for luminaires. Conveniently mounted outside the shield SmartFilter RFI/EMI FILTER PROVEN to work with MRI equipment (up to 7 Tesla) from all of the major manufacturers. Industry leading RFI/EMI protection. Easily installed on exterior surface of shield Page 6

7 SECTION I: SmartLED MRI LUMINAIRE SYSTEM Design Function Aperture Product # Performance Lumens Watts Page 1500 LUMEN MRI DOWNLIGHT, ADJUSTABLE AND WALL WASH LUMINAIRES Open Appearance Downlight 4 MRR L Open Appearance Downlight 6 MRR L Open Appearance Adjustable 4 MRR L Open Appearance Wall Wash 4 MRR L Flare with Regressed Lens Downlight 6 MRR L Flare with Regressed Lens Downlight 6 MRR L IP65 Infection Control Downlight 7 MRR L Square Flare with Regressed Lens Downlight 4 MRS L MRI SCONCES - ADA COMPLIANT - ONLY 2½ PROTRUSION FROM WALL 14 Round Center Field Edge Glow Sconce 14 MSR Square Center Field Edge Glow Sconce 10 MSS SmartLED MRI Table of Contents - continued on pages 8-9 PLEASE VISIT FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). Page 7

8 SECTION I: SmartLED MRI LUMINAIRE SYSTEM Design Function Aperture Product # Performance Lumens Watts Page 2500 LUMEN MRI DOWNLIGHT, ADJUSTABLE AND WALL WASH LUMINAIRES Open Appearance Lensed Downlight 6 MRR L Open Appearance Lensed Adjustable 6 MRR L Open Appearance Lensed Wall Wash 6 MRR L Flare with Regressed Lens Downlight 6 MRR L Flare with Regressed Lens Downlight 6 MRR L IP65 Infection Control Downlight 8 MRR L Surface Mount Flat Trim Downlight 12 MSR L K-Lens Recessed Square Downlight 8 MRS L LUMINAIRE AND SCONCE OPTIONS 14 For Luminaires SmartSupply (1400mA) Remote Driver LPS-1220A For Luminaires SmartFilter RFI/EMI Filter RFI-3100D 15 For Luminaires SmartPower (Optional) Emergency Power Supply EMI DOWNLIGHTING TYPICAL SYSTEM CONFIGURATION AND PHOTOMETRIC PERFORMANCE 16 TYPICAL SYSTEM CONFIGURATIONS FOR DOWNLIGHTING 17 TYPICAL WIRING OVERVIEW AND WIRING DIAGRAM FOR LUMINAIRES DOWNLIGHTING LUMINAIRE SYSTEM DESIGN GUIDE AND CHECKLIST 20 PLEASE VISIT FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). Page 8

9 SECTION I: SmartLED MRI SCENIC PANEL SYSTEM Design Function Aperture Product # Performance Watts Page Scenic Panel: 2x2 Building Block Configuration 24 MRP SCENIC PANEL IMAGES 22 SCENIC PANEL CONFIGURATIONS & PRODUCT SPECIFICATION GUIDE 23 For Scenic Panels SmartSupply (700mA) Remote Driver LPS-0700A 24 For Scenic Panels SmartFilter RFI/EMI Filter RFI-3100D TYPICAL SYSTEM CONFIGURATION FOR SCENIC PANELS & SCENIC PANEL CHECKLIST 25 TYPICAL WIRING OVERVIEW AND WIRING DIAGRAM FOR SCENIC PANELS SECTION I: SmartLED MRI SCENIC PANEL SYSTEM SmartLED SCENIC PANELS Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. Creates a soothing environment to reduce patient stress and assist in the healing process. Configurable overall size to suit the unique dimensions of each MRI suite. Page 9

10 MRI LUMINAIRE SYSTEM: 1500 LUMEN SERIES (-1500L) Downlights 4 MRR L 6 MRR L 1221 LUMENS 20W MFL (STD) SC: LPW: LUMENS Cone of Light -SPT -NFL -WFL Lm: 1336 SC: 0.4 Lm: 1250 SC: 0.5 Cone of Light -NFL -WFL 20W MFL (STD) SC: LPW: Lm: 1279 Lm: 1150 SC: 0.5 SC: 1.5 Lm: 968 SC: Adjustable 1189 LUMENS 20W NFL (STD) SC: 0.4 LPW: SPT -MFL -WFL Lm: 1205 SC: 0.3 Lm: 1135 SC: 0.6 Lm: 847 SC: 1.0 MRR L 2011 Architectural SSL Product Innovation Award 4 Wall Wash 1035 LUMENS 20W LPW: Cone of Light Key Ft. Distance from fixture FC Footcandles at nadir (0 ) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir. MRR L Page 10

11 MRI LUMINAIRE SYSTEM: 1500 LUMEN SERIES (-1500L) 6 Lensed Downlights MRR L 6 MRR L 2011 Architectural SSL Product Innovation Award 1329 LUMENS 20W MFL (STD) SC: LPW: LUMENS Cone of Light -NFL -WFL Lm: 1341 SC: 0.5 Lm: 1252 SC: 1.3 Cone of Light -NFL -WFL 20W MFL (STD) SC: LPW: Lm: 1344 Lm: 1249 SC: 0.4 SC: IP65 Downlight MRR L IP 65 Cone of Light -NFL -WFL 20W MFL (STD) SC: LPW: Lm: 1317 Lm: 1187 SC: 0.5 SC: LUMENS Lensed Downlight 4 MRS L 1342 LUMENS Cone of Light -NFL -WFL 20W MFL (STD) SC: LPW: Lm: 1358 Lm: 1028 SC: 0.4 SC: Page 11

12 MRI LUMINAIRE SYSTEM: 2500 LUMEN SERIES (-2500L) 6 Downlight 2490 LUMENS 35W MFL (STD) SC: LPW: Cone of Light -SPT -NFL -WFL Lm: 2481 SC: 0.2 Lm: 2667 SC: 0.3 Lm: 2118 SC: 1.3 MRR L 6 Adjustable 2352 LUMENS 35W NFL (STD) SC: 0.4 LPW: SPT Lm: 2342 SC: 0.3 -MFL Lm: 2310 SC: 0.7 MRR L 6 Wall Wash 2164 LUMENS 35W LPW: Cone of Light Key Ft. Distance from fixture FC Footcandles at nadir (0 ) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir. MRR L Page 12

13 MRI LUMINAIRE SYSTEM: 2500 LUMEN SERIES (-2500L) Lensed Downlights 6 MRR L 6 MRR L 2490 LUMENS 35W MFL (STD) SC: LPW: LUMENS Cone of Light -NFL -WFL Lm: 2458 SC: 0.4 Lm: 2281 SC: 1.2 Cone of Light -NFL -WFL 35W MFL (STD) SC: LPW: Lm: 2458 Lm: 2281 SC: 0.4 SC: 1.2 IP65 Downlight 8 MRR L IP LUMENS Cone of Light -NFL -WFL 35W MFL (STD) SC: LPW: Lm: 2291 Lm: 2179 SC: 0.4 SC: 1.0 Surface Downlight 12 MSR L 2344 LUMENS Cone of Light 35W WFL SC: LPW: Lensed Downlight 8 MRS L 1814 LUMENS Cone of Light 35W WFL (STD) SC: LPW: Cone of Light Key Ft. Distance from fixture FC Footcandles at nadir (0 ) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir. Page 13

14 MRI SCONCE SYSTEM: ADA COMPLIANT - 2½ FROM THE WALL MSR LED Light Engine 1300 lumen, 20 watt LED array 3500 K CCT standard 90,000 hours (L70) Fully sustainable: Removable for servicing Sconce Assembly Decorative brushed aluminum faceplate and housing with clear 1/4 acrylic diffuser Illuminated center field and edge glow. White standard or specify optional color. See below. Brushed Anodized Aluminum Housing 2 ½ depth meets all ADA requirements All aluminum construction maximizes cool operation and component life Optional housing and faceplate finishes Installation Wall or ceiling mount Universal back plate mounts to any non-ferromagnetic octagon or 4 square J-box (provided by others). MSS Red Wing Red Option -RE Circadian Red / Amber Option -RA Tiger Orange Option -OR Wolverine Maize Option -YE Spartan Green Option -GN Lion Blue Option -BL Custom Image / Logo Option -CI POPULAR LUMINAIRE OPTIONS DOWNLIGHTS Color Temperature (CCT) -27K Color temperature 2700 K instead. -30K Color temperature 3000 K instead. -41K Color temperature 4100 K. Consult factory. -HC 90+ CRI instead. Use with Option -27K or -30K only. Reduces output by ~15%. Optics -NFL Narrow flood distribution. -SPT Spot distribution. -WFL Wide flood distribution. Lenses & Trims -13 Tamper resistant prismatic high strength spread acrylic above 1/8 flat polycarbonate. Also see Option prismatic high strength acrylic lens. Also see Option White translucent flat poly diffuser instead. -23 Frosted microprismatic lens instead. -26 Tamper-resistant button head recessed hex screw with center pin and 1 key / 10 fixtures. -30 All white acrylic enameled cone. -31 White acrylic enameled cone flange (only). Page White oversize trim ring. Specify O.D. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -70 SofTex Clear self-flanged cone. (CP x.95) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin white (only) trim finish. -WA White acrylic (flat) diffuser instead. Surface Housing Finishes (White standard) -35 Natural aluminum acrylic enamel. -38 Black acrylic enamel. -94 Custom color. Specify. Consult factory. Other -79 Extension collar for up to 2 thick ceilings. -99 Special modification. Consult factory. SCONCES (See specification sheets for details.) Faceplate & Housing -30 White baked enamel finish instead. -35 Natural Aluminum baked enamel finish instead. -38 Black baked enamel finish instead. -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin white (only) finish. Colors: Center Field & Edge Glow -BL Blue filter. -CF Custom filter color (Rosco). Specify. -GN Green filter. -OR Orange filter. -RA Red amber filter. -RE Red filter. -YE Yellow filter. Other -CI Custom image (color/logo) in center field of sconce.

15 MRI SmartSupply REMOTE DIMMING DRIVER - REQUIRED LPS-1220A Full range 100% to 0.2% dimming (see page 18 or consult factory for compatible controls). Over wattage, cross channel, and electrical fast transient (EFT) protection. Mounted outside MRI shield (not directly to shield). Input: VAC / 50-60Hz isolated circuit only. Maximum continuous input voltage 290V. Load insensitive. Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply to luminaires. FIVE YEAR Limited Warranty IES Progress Report Selection (6) Channels (Circuits) Maximum Distance Per Channel With 1500 Lumen Series (-1500L) SmartLED Luminaires Up to (2) luminaires / channel Up to (12) luminaires / SmartSupply (1) luminaire / channel: 300 feet (2) luminaires / channel: 100 feet * With 2500 Lumen Series (-2500L) SmartLED Luminaires (1) luminaire / channel Up to (6) luminaires / SmartSupply (1) luminaire / channel: 200 feet *Distance to the farthest fixture SmartFilter DC RFI / EMI FILTER - REQUIRED RFI-3100D RFI-3100D 2011 IES Progress Report Selection MRI SYSTEM ORDERING EXAMPLE Industry leading RFI and EMI protection Superior insertion loss of 100 db (min.) Fully protects 20 khz to 1.0 GHz One filter protects up to three SmartSupply channels Up to two filters required per SmartSupply Mounted on outside surface of MRI shield FIVE YEAR Limited Warranty Quantity Product Description 12 MRR L-41K-WFL Luminaires 1 LPS-1220A SmartSupply (1400mA) driver (required) 2 RFI-3100D SmartFilter DC RFI/EMI filter (required) SmartPower EMERGENCY BACKUP SYSTEM - OPTIONAL EMI High efficiency pure sine wave inverter Operates up to two fully loaded SmartSupply drivers 100% light output for up to 2 hours 120 / 277V, 60Hz input Less than 0.05 seconds transfer time May be mounted up to 1000 feet from load UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements THREE YEAR Limited Warranty. SEVEN YEAR pro-rata battery warranty Page 15

16 MRI LUMINAIRE SYSTEM: TYPICAL CONFIGURATION Photo courtesy of Haselden Construction Typical MRI Suite Lighting Zones and Component Locations 14' - 6" 6' - 10" 22' - 8" 6' - 6" Equipment Room (1) EMI (2) LPS-1220A (4) RFI-3100D MRI Room MRI Zone fc Zone 2 85 fc Zone 3 45 fc Control Room 19' - 9" MRI Shield 0-10VDC Dimmer PRODUCTS Product Type Product # Qty Location Adjustable Task Lighting Fixed Ambient Downlights Remote Drivers EMI/RFI Filters Emergency Inverter 0-10VDC Dimmers Page 16 MRR Over the transfer table MRR Perimeter of MRI room LPS-1220A 2 Outside the MRI shield RFI-3100D 4 On the MRI shield EMI Outside the MRI shield See page 26 2 In the control room PHOTOMETRIC PERFORMANCE Luminaires Zone Location fc Product # Qty 1 Transfer Table 100 MRR Near Transfer Table 85 3 MRI Perimeter 45 MRR

17 MRI LUMINAIRE SYSTEM: TYPICAL CONFIGURATIONS 1500 Lumen (20W) Luminaires RFI / EMI Shield Kirlin SmartLED Luminaire Up to (12) 20W luminaires per SmartSupply Up to (2) luminaires per SmartSupply channel (circuit). Each color represents (1) set of (3) channels Kirlin SmartFilter RFI-3100D (Required) (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels Up to (2) filters required per SmartSupply Mounted on outside surface of MRI shield Kirlin SmartSupply LPS-1220A (Required) (6) channels - Up to (2) luminaires per channel - Up to (12) luminaires per SmartSupply Max distance per channel with (1) luminaire per channel with (2) luminaires per channel Mounted outside MRI shield (not directly to shield) Kirlin SmartPower EMI (Optional) Max distance from load: 1000 Mounted outside MRI shield (not directly to shield) 2500 Lumen (35W) Luminaires RFI / EMI Shield Kirlin SmartLED Luminaire Up to (6) 35W luminaires per SmartSupply (1) luminaire per SmartSupply channel (circuit). Each color represents (1) set of (3) channels Kirlin SmartFilter RFI-3100D (Required) (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels Up to (2) filters required per SmartSupply Mounted on outside surface of MRI shield Kirlin SmartSupply LPS-1220A (Required) (6) channels - Up to (1) luminaire per channel - Up to (6) luminaires per SmartSupply Max distance per channel: with (1) luminaire per channel Mounted outside MRI shield (not directly to shield) Kirlin SmartPower EMI (Optional) Max distance from load: 1000 Mounted outside MRI shield (not directly to shield) Page 17

18 MRI LUMINAIRE SYSTEM: TYPICAL WIRING OVERVIEW This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10VDC dimmer* connected to the master 0-10VDC input of the SmartSupply. Shown with: LPS-1220A RFI-3100D Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty. Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (1400mA) to luminaires. CHANNELS 5, 6 SmartSupply LPS-1220A (Output) JUNCTION BOX CHANNELS 1, 2 CHANNELS 3, 4 CHANNELS 1, 2 CHANNELS 3, 4 CHANNELS 5, 6 GREY SmartFilter RFI-3100D SmartFilter RFI-3100D PURPLE SmartSupply LPS-1220A (Input) CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 CHANNEL 5 CHANNEL L (35W) LINE NEUTRAL WALL BOX DIMMER* 1500L (20W) AC INPUT Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter. * Kirlin recommends using the following compatible 0-10VDC dimmers: Leviton IP710-DLX NFTV ** Nova ZP600FAM-XXX Sunrise NTSTV-DV ** Nova T Lightolier MP1500FAM-XXX Momentum Lutron DVTV Diva V2000FAMU Vega DVSTV ** Diva Acuity ISD BC V-600 w/grx-tvi Vareo Page 18

19 MRI LUMINAIRE SYSTEM: WIRING DIAGRAM Two 1500 Lumen Series (20W) Luminaires on One Circuit DO NOT CONNECT LED luminaires to energized driver. Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty. One 1500 or 2500 Lumen Series (20W or 35W) Luminaire on One Circuit RED (+) BLACK (-) RED (+) BLACK (-) Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (1400mA) to luminaires. DO NOT CONNECT wire shields to the luminaires. RED (+) BLACK (-) RED (+) CH 4 BLACK ( ) CH 4 RED (+) CH 5 BLACK ( ) CH 5 RED (+) CH 6 BLACK ( ) CH 6 Wire shields INSIDE room MUST be connected to room shield grounding bar. INSIDE MRI ROOM RED (+) CH 1 BLACK ( ) CH 1 RED (+) CH 2 BLACK ( ) CH 2 RED (+) CH 3 BLACK ( ) CH 3 ROOM SHIELD GROUNDING BAR SmartFilter RFI-3100D ROOM SHIELD OUTSIDE MRI ROOM SmartFilter RFI-3100D RED (+) CH 4 BLACK ( ) CH 4 WHITE (+) CH 5 GREEN ( ) CH 5 RED (+) CH 6 BLACK ( ) CH 6 Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (1400mA) to luminaires. DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar. WHITE (+) CH 1 GREEN ( ) CH 1 RED (+) CH 2 BLACK ( ) CH 2 WHITE (+) CH 3 GREEN ( ) CH 3 Electrical Input: VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V. ZONE 4 (NOT USED) ZONE 1 ZONE 3 ZONE 2 SmartSupply LPS-1220A* * DO NOT MOUNT OR CONNECT SmartSupply (1400mA) to room shield. Page 19

20 MRI LUMINAIRE SYSTEM: DESIGN GUIDE Recommended Luminaires Ceiling Height Lower Ceilings (8-9 ) Higher Ceilings (8-12 ) Wide Distribution Recessed Ambient Task Accent Specifiable Distribution Patient Table (Aimable) Wall Wash Infection Control * Surface Ambient Wide Distribution MRR MRR Lumen Series (20W) MRR MRR MRR MRR MRR MRS MRR MRR Lumen Series (35W) MRR MRR MRR MRR MSR MRS * Infection Control Key antimicrobial white finish standard. MRI LUMINAIRE / SCONCE SYSTEM: CHECK LIST 1. Select the type and quantity of SmartLED Luminaires. See pages for available models. 2. Determine the quantity and remote location of the SmartSupply(s). See page Determine the quantity of SmartFilters. See page Select dimming controls. See page Determine the quantity and remote location (outside MRI shield) of the dimming controls. m FOR INSTALLATION INSTRUCTIONS AND WIRING DIAGRAMS. Page 20

21 MRI SCENIC PANEL SYSTEM: MRP SERIES Selection of beautiful smooth panel artwork attractively backlit Regressed trim provides architectural skylight effect Wave guide lens provides superior uniform illumination Ultra-shallow (2 ) recessed aluminum housing Driverless, 20 watt, low voltage, Class II, DC powered % full range dimming 60,000 hours (L70) life Requires SmartSupply LPS-0700A and SmartFilter RFI-3100D Regressed bevel provides architectural skylight effect Use multiple 2x2 Scenic Panels to create a soothing and attractive luminous ceiling 23¾ Sq. [603mm] Ultra-shallow (2 ) aluminum housing requires minimal plenum space Page 21

22 MRI SCENIC PANEL SYSTEM: IMAGES Artwork Select artwork by adding the option code (i.e., -A01) of the respective artwork. For custom artwork, use Option -A99. -A01 -A02 -A03 -A04 Custom Artwork -A05 -A06 -A99 Dividing and Cropping Artwork When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example: -4x4-6x4-4x6 To see how your artwork will divided and cropped, consult factory. Page 22

23 MRI SCENIC PANEL SYSTEM: PANEL CONFIGURATIONS 1. Use MRP as base catalog number, then add configurations and selections as follows. 2. Choose overall size and orientation of the display using the Overall Size and Orientation table below. 3. Select artwork with option codes (i.e., -A01). Consider how the artwork will be displayed. See Dividing and Cropping Artwork. 4. Add appropriate quantity of SmartSupply LPS-0700A and SmartFilter RFI-3100D (details follow). 5. Following the submission of your order, and before production, you will receive a proof for your review and approval. Overall Size and Orientation Nominal Dimensions Landscape Portrait Fixture Qty Arrangement Option Arrangement Option 2 x 2 1-2x2 2 x 4 2-4x2-2x4 4 x 4 4-4x4 4 x 6 6-6x4-4x6 6 x 6 9-6x6 6 x x6-6x8 8 x x8 Custom Size -9x9 Specify number of panels and orientation of artwork. SCENIC PANEL PRODUCT SPECIFICATION EXAMPLE Example: Scenic Panel Product Number MRP x6 -A01 Size and Orientation Option* Artwork Option Page 23

24 MRI SCENIC PANEL: SmartSupply DRIVER - REQUIRED LPS-0700A Full range 100% to 0.2% dimming (see page 26 or consult factory for compatible controls). Mounted outside MRI shield (not directly to shield). Over wattage, cross channel, and electrical fast transient (EFT) protection. Input: VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V. Load insensitive. Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply to luminaires. FIVE YEAR Limited Warranty. With Scenic Panels (20W) (12) Channels (Circuits) Maximum Distance Per Channel (1) scenic panel / channel Up to (12) scenic panels / SmartSupply 100 feet SmartFilter DC RFI / EMI FILTER - REQUIRED Industry leading RFI and EMI protection Superior insertion loss of 100 db (min.) Fully protects 20 khz to 1.0 GHz One filter protects up to three Scenic Panel SmartSupply channels Up to four filters required per Scenic Panel SmartSupply Mounted on outside surface of MRI shield FIVE YEAR Limited Warranty RFI-3100D 2011 IES Progress Report Selection MRI SCENIC PANEL SYSTEM ORDERING EXAMPLE Quantity Product Description 12 MRP x4-A03 Scenic Panels 1 LPS-0700A Scenic Panel SmartSupply (700mA) driver (required) 4 RFI-3100D SmartFilter DC RFI/EMI filter (required) Page 24

25 MRI SCENIC PANEL SYSTEM: TYPICAL CONFIGURATION Scenic Panels (20W) RFI / EMI Shield Kirlin SmartLED Scenic Panels Up to (12) 20W scenic panels per SmartSupply (1) scenic panel per SmartSupply channel (circuit). Each color represents (1) set of (3) channels Kirlin SmartFilter RFI-3100D (Required) (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels Up to (4) filters required per SmartSupply Mounted on outside surface of MRI shield Kirlin SmartSupply LPS-0700A (Required) (12) channels - (1) scenic panel per channel - Up to (12) scenic panels per SmartSupply Max distance per channel with (1) scenic panel per channel Mounted outside MRI shield (not directly to shield) MRI SCENIC PANEL SYSTEM: CHECK LIST 1. Select the quantity and layout of SmartLED scenic panels. See page Select the image. Consider how the image will be oriented, cropped and divided. See page Determine the quantity and remote location of the SmartSupply(s). See page Determine the quantity of SmartFilters. See page Select dimming controls. See page Determine the quantity and remote location (outside MRI shield) of the dimming controls. FOR INSTALLATION INSTRUCTIONS AND WIRING DIAGRAMS. Page 25

26 MRI SCENIC PANEL SYSTEM: TYPICAL WIRING OVERVIEW This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10VDC dimmer* connected to the master 0-10VDC input of the SmartSupply. Shown with: LPS-0700A RFI-3100D Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty. Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires. CHANNELS 7-9 CHANNELS SmartSupply LPS-0700A (Output) JUNCTION BOX CHANNELS 7-9 SmartFilter RFI-3100D SmartFilter CHANNELS 1-3 CHANNELS 4-6 CHANNELS 1-3 CHANNELS CHANNELS 4-6 SmartFilter RFI-3100D SmartFilter RFI-3100D SmartFilter GREY RFI-3100D PURPLE SmartSupply LPS-0700A (Input) CHANNEL 1 CHANNEL 2 CHANNEL 3 Smar tled Scenic Panels LINE NEUTRAL WALL BOX DIMMER* AC INPUT Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter. * Kirlin recommends using the following compatible 0-10VDC dimmers: Leviton IP710-DLX NFTV ** Nova ZP600FAM-XXX Sunrise NTSTV-DV ** Nova T Lightolier MP1500FAM-XXX Momentum Lutron DVTV Diva V2000FAMU Vega DVSTV ** Diva Acuity ISD BC V-600 w/grx-tvi Vareo Page 26

27 MRI SCENIC PANEL SYSTEM: WIRING DIAGRAM One Smar tled Scenic Panel Per Circuit DO NOT CONNECT LED luminaires to energized driver. Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty. RED (+) BLACK (-) Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires. DO NOT CONNECT wire shields to the luminaires. RED (+) CH 10 BLACK ( ) CH 10 RED (+) CH 11 BLACK ( ) CH 11 RED (+) CH 12 BLACK ( ) CH 12 Wire shields INSIDE room MUST be connected to room shield grounding bar. INSIDE MRI ROOM RED (+) CH 1 BLACK ( ) CH 1 RED (+) CH 2 BLACK ( ) CH 2 RED (+) CH 3 BLACK ( ) CH 3 ROOM SHIELD GROUNDING BAR SmartFilter RFI-3100D ROOM SHIELD OUTSIDE MRI ROOM SmartFilter RFI-3100D RED (+) CH 10 BLACK ( ) CH 10 WHITE (+) CH 11 GREEN ( ) CH 11 RED (+) CH 12 BLACK ( ) CH 12 Requires 18 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires. DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar. WHITE (+) CH 1 BLACK ( ) CH 1 RED (+) CH 2 BLACK ( ) CH 2 GREEN (+) CH 3 BLACK ( ) CH 3 Electrical Input: VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V. ZONE 4 ZONE 1 SmartFilter RFI-3100D ZONE 3 ZONE 2 To RFI-3100D SmartFilter SmartFilter SmartSupply LPS-0700A* * DO NOT MOUNT OR CONNECT SmartSupply (700mA) to room shield. Page 27

28 SECTION II: EXAM LIGHTING (RECESSED DOWNLIGHT / ADJUSTABLE) THREE LEVELS OF INFECTION CONTROL PROTECTION HIGHER QUALITY LIGHT Select delivered lumens from in downlight or adjustable designs. Choose the color of your light: 3500K (neutral white, standard), 3000K (warm white), 4100K (cool white) or 5000K (daylight white). High CRI available (Option -HC) for accurate tissue color rendering: CRI 90+ with high R9 (Red), R13 and R15 (Skin Colors). A SAFER ENVIRONMENT Fully recessed fixtures provide an open work space. IP65 trims minimize the likelihood of pathogens passing through the fixture. antimicrobial finish inhibits the growth of pathogens. Compact and smooth trim and lens are easy to clean and disinfect. Impact resistant lenses available (ideal for emergency departments and psychiatric units). ISO 5 Class 100 sealed luminaires for cleanroom applications. GREATER PERFORMANCE Dimming down to 10% permits staff to finely tune light levels for specific tasks, each clinician and time of day. Higher delivered lumens and 50% energy savings over fluorescent troffers. Multi-light system removes debilitating shadows. LEVEL 1 PROTECTION LENSED LEVEL 2 PROTECTION IP65 (SEALED TRIM) LEVEL 2 + PROTECTION IP65 (SEALED TRIM) AND TAMPER RESISTANT IP65 IP 65 VR LEVEL 3 PROTECTION CLASS 100 (SEALED FIXTURE) LEVEL 3 + PROTECTION CLASS 100 (SEALED FIXTURE) AND TAMPER RESISTANT IP65 CLASS IP65 ISO CLEANROOM CLASS ISO CLEANROOM VR Page 28

29 SECTION II: EXAM LIGHTING (RECESSED DOWNLIGHT / ADJUSTABLE) Infection Control Application Function Aperture Product # Performance Lumens Watts Page Level 1 Protection Antimicrobial Finish Regressed Lens Downlight 7 MRR L MRR L Level 1 Protection Level 1 Protection Antimicrobial Finish Regressed Lens Antimicrobial Finish Regressed Lens MRR L Adjustable 7 MRR L Downlight 4 x 9 MRT L Level 1 Protection Antimicrobial Finish Regressed Lens Downlight 5 x 11 MRT L MRT L Level 2 Protection Level 2 Protection IP65 Rated Finish Regressed Lens IP65 Rated Finish Regressed Lens Downlight 8 Adjustable 8 MRR L MRR L MRR L MRR L Level 2+ Protection Level 2+ Protection IP65 Rated - Tamper Resistant Psychiatric/ED IP65 Rated - Tamper Resistant Psychiatric/ED Downlight 8 Adjustable 8 MRV L MRV L MRV L MRV L Level 3 Protection Class 100 Cleanroom Finish OR/Hybrid OR Downlight 7 MRR L Level 3 Protection Class 100 Cleanroom Finish OR/Hybrid OR Downlight 8 MRR L MRR L Level 3 Protection Class 100 Cleanroom Finish OR/Hybrid OR Adjustable 8 MRR L MRR L Level 3+ Protection Level 3+ Protection Class 100 Cleanroom Finish Tamper Resistant Psychiatric/OR Class 100 Cleanroom Finish Tamper Resistant Psychiatric/OR Downlight 7 MRV L MRV L Downlight 8 MRV L INSTALLATIONS, OPTIONS AND ORDERING PLEASE VISIT FOR KIRLIN TUNGSTEN HALOGEN EXAM LIGHTING PRODUCTS IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). Page 29

30 SECTION II: EXAM LIGHTING LEVEL 1 PROTECTION LENSED 7 Cone of Light Downlight MRR L MRR L LUMENS 55W fc on Task: 8 Ceiling 3 6 Work Plane Applications: Patient Room Cardiac Cath Labor and Delivery Radiology PreOp / PostOp Veterinary Autopsy Adjustable 4845 LUMENS 55W fc on Task: 8 Ceiling 3 6 Work Plane MRR L MRR L 4 x 9 Cone of Light LUMENS 2X35W fc on Task: 8 Ceiling 3 6 Work Plane Downlights MRT L 5 x 11 Applications: Patient Room ICU / NICU Labor and Delivery PreOp / PostOp Veterinary Autopsy Cone of Light MRT L MRT L 6410 LUMENS 2X42W fc on Task: 8 Ceiling 3 6 Work Plane Page 30

31 SECTION II: EXAM LIGHTING LEVEL 2 PROTECTION IP65 (SEALED TRIM) IP 65 8 Cone of Light Downlight Adjustable MRR L MRR L LUMENS 55W 4487 LUMENS 55W fc on Task: 8 Ceiling 3 6 Work Plane Applications: ICU / NICU PreOp / PostOp Autopsy Veterinary PT / CT Scan Infection Control Areas MRR L MRR L fc on Task: 8 Ceiling 3 6 Work Plane LEVEL 2 + PROTECTION IP65 (SEALED TRIM) AND TAMPER RESISTANT IP65 VR 8 Cone of Light Downlight MRV L MRV L LUMENS 55W fc on Task: 8 Ceiling 3 6 Work Plane Applications: Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room Adjustable 3986 LUMENS 55W MRV L MRV L fc on Task: 8 Ceiling 3 6 Work Plane Page 31

32 SECTION II: EXAM LIGHTING LEVEL 3 PROTECTION CLASS 100 (SEALED FIXTURE) IP65 CLASS ISO CLEANROOM 7 Cone of Light Downlights MRR L 8 MRR L MRR L 2013 IES Progress Report Selection 1317 LUMENS 15W 5293 LUMENS 55W Cone of Light fc on Task: 8 Ceiling 3 6 Work Plane fc on Task: 8 Ceiling 3 6 Work Plane Applications: Operating Room Hybrid OR Intraoperative OR CCU Cleanroom Cardiac Cath Interventional Radiology Adjustable 4487 LUMENS 55W MRR L MRR L LEVEL 3 + PROTECTION CLASS 100 (SEALED FIXTURE) AND TAMPER RESISTANT 7 Cone of Light fc on Task: 8 Ceiling 3 6 Work Plane IP65 CLASS ISO CLEANROOM VR Downlight Adjustable MRV L 8 MRV L MRV L 1197 LUMENS 15W 4787 LUMENS 55W Cone of Light fc on Task: 8 Ceiling 3 6 Work Plane fc on Task: 8 Ceiling 3 6 Work Plane Applications: Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room Page 32

33 KIRLIN LED EXAM LIGHTING OUTPERFORMS ANTIQUATED TROFFERS Performance Over 50% energy savings Higher delivered lumens Fewer luminaires, lower cost Exceeds IES recommended light levels Better illumination uniformity; no glare Instant on, reliable dimming Infection Control antimicrobial finish Smaller lens and trim for faster cleaning Award winning cleanroom versions offered Installation and Maintenance Maintenance-free LEDs Smaller size for easier installation Shallow depth housings fit anywhere Reliability IEC/EN medical listing FCC Part 15 EMI/RFI emissions SmartPower Emergency inverter (EMI-21220) available. Provides 100% lumen output for up to two hours IES Progress Report Selection LIGHTING PERFORMANCE Zone Location fc Luminaires* Fixture Qty 1 OR Table 800 MRR L 6 2 Near OR Table OR Perimeter 100 MRR L 15 * See for specification sheets. Operating Room Zones 5' - 6" ' - 7" Footcandles on Operating Table 30' - 0 2' - 7" Zone fc 6' - 0" ' - 0" Zone fc 6' - 6" Zone fc 24' - 0 Zone fc Page 33

34 SECTION II: EXAM LIGHTING TYPICAL INSTALLATIONS Two Adjustable Exam Lights Placed 4 apart on centers over the head and foot of the bed. Two Adjustable Exam Lights in NICU Placed over the foot corners of the bed. LUMINAIRE 4 [112cm] LUMINAIRES 4 [112cm] 2 8 [81cm] 8 [244cm] 22 (35 Max) SITE 8 [244cm] 23 (35 Max) SITE 30 3 [91cm] 3 4 [101cm] Front View Side View One Adjustable Exam Light Placed over the head (or foot) of the bed to avoid obstructions in ceiling. One Fixed Exam Light Placed over center of the bed. LUMINAIRE LUMINAIRE 22 (35 Max) 8 [244cm] SITE 8 [244cm] SITE 3 [91cm] 3 [91cm] Page 34

35 SECTION II: EXAM LIGHTING POPULAR OPTIONS Input Power V (50-60Hz) input and thermal protector V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory. LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with Option -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L or 100% for -1500L. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply driver or with Option EM INTERNAL emergency inverter. Delivers 500 lumens. Run time: 90+ minutes. -EMH INTERNAL emergency inverter. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply driver (instead of standard internal driver), sold separately. Drives up to (3) -5000L or -3500L, (12) -1500L luminaires. Order LPS-1220A (0-10V analog) for 100-1% PWM dimming. See LPS-1220A specification sheet at Color Temperature (CCT) -27K Color temperature 2700 K instead. 85 CRI. -30K Color temperature 3000 K instead. 85 CRI. -41K Color temperature 4100 K instead. 85 CRI. -50K Color temperature 5000 K instead. 85 CRI. -HC 90+ CRI instead or 3000 K only. Reduces output by ~15%. Optics (-NFL Standard) -MFL Medium flood distribution instead. (See specification sheets for details.) Trims -32 White oversize trim ring. Specify O.D. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -GE Green filter added to lens assembly. Other -79 Extension collar for up to 2 thick ceilings. -99 Special modification. Consult factory. -FD Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. -FS In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead. -SH Sealed housing and junction box. Meets ASTM E283 restricted airflow of 2 CFM maximum. SmartPower EMERGENCY BACKUP SYSTEM - OPTIONAL EMI High efficiency pure sine wave inverter Operates up to (6) -5000L series fixtures 100% light output for up to two hours 120 / 277V, 60Hz input Less than 50 milliseconds transfer time May be mounted up to 1000 feet from load UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements THREE YEAR Limited Warranty LUMINAIRE ORDERING EXAMPLE MUST SPECIFY OPTIONAL Product Number Voltage Options MRV L MRV L -120 (120 volts) -277 (277 volts) -97 (Specify other) See Options above. Ordering Example: MRV L K-MFL LUMEN SERIES AVAILABLE Lumen Series Code Nominal Lumens -5000L 5000 Lumens -3500L 3500 Lumens -1500L 1500 Lumens Page 35

36 SECTION III: MOTORIZED EXAM LIGHTING & CONTROLS HIGHER QUALITY LIGHT WITH OPTeCOLOR Choose the color of your light: 3500K (Neutral white: Standard), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K) Ultra-high 95+ CRI with high R9 (Red), R13 and R15 (Skin Colors) for accurate tissue color rendering. High illuminance for deep cavities or challenging positions. Up to 9000 delivered footcandles from 5 feet, dimmable to 10%. Common CRI High CRI GREATER CONTROL Independent control of each lighthead permits adjustable pattern of light and dual task illumination. Intuitive and responsive controls allow for quick and accurate adjustment of direction and intensity of the light. Angles of illumination up to 60 ensure the task is properly illuminated regardless of the task location or clinicians position. Dimming down to 10% permits staff to finely tune levels, as needed. A SAFER ENVIRONMENT Recessed fixtures provide an open work space. The light remains recessed, protecting the patient from contaminants near or above the ceiling. IP65 trims with antimicrobial finish protect against pathogens. IP65 IES Progress Report Selections GREATER COMFORT Cool LED illumination does not project heat toward the room, assuring patient and practitioner comfort and avoiding tissue desiccation. Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; Remote control does not need to be used near the patient. Remote control technology employs invisible infrared signal, preventing the triggering of photosensitive conditions (migraines, epileptic seizures, stress). DEPENDABILITY Redundancy of LED circuits ensures illumination at all times. Redundancy of controls (wall or remote) ensures 24/7 adjustability of illumination intensity and position. Impact resistant design protects remote control. Loss deterring beeper feature on the remote control reminds staff to return the remote to its home plate on the wall control panel. Page 36

37 SECTION III: MOTORIZED EXAM LIGHTING & CONTROLS Name Application Design Delivered Lumens Total Watts Aperture Product # Page REMOTE CONTROL AND WALL CONTROL WITH RECESSED MOTORIZED LUMINAIRE(S) INFRALED 60 LDRP/OB Pair MRS INFRALED Intraoperative OR Hybrid OR ICU/CCU Cardiac Cath Pair MRR INFRALED ED Patient Room Single MRR WALL CONTROL WITH RECESSED MOTORIZED LUMINAIRE(S) OPTeLED PICU/NICU ED Trauma Pair MRR OPTeLED PICU/NICU Patient Room Autopsy Single MRR PLEASE VISIT FOR KIRLIN TUNGSTEN HALOGEN MOTORIZED EXAM LIGHTING IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). Page 37

38 SECTION III: MOTORIZED EXAM LIGHTING LED Remote Controlled Motorized Recessed Patient Lighting System MRS (Two Light System) FEATURES Light delivered at angles up to 60 to match the clinician s line of site for superior illumination of the birthing canal. Four OPTeCOLOR LED light heads per system deliver up to 6000 fc with no heat in the beam. OPTeCOLOR LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissue and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. Redundancy of controls and electronic components ensures control of fixtures and at least 50% illumination at all times. Fully recessed fixtures with antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. Full control of lighting system (direction, intensity, power) from both remote and wall controls. Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. Kirlin s exclusive three year limited warranty (one year remote control). APPLICATIONS Birthing Suites 2015 IES Progress Report Selection POPULAR OPTIONS Input Power V (50-60Hz) input and thermal protector /120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory /120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load. Color Temperature (CCT) -41K 4100 K instead of 3500 K. 95+ CRI. -50K 5000 K instead of 3500 K. 95+ CRI. Trim and Other -47 Plaster frame bottom pan. For installation in hard ceilings. -87 Custom length (> 35 feet) plenum rated wall control cables (4). Consult factory. -94 Custom color self-flanged flare trim instead. Consult factory. -99 Special modification. Consult factory. -BI Beeper (remote control) inactivated by factory. -RC Extra remote control. -RS Remote infrared sensor with 35 cable. -SE Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes. (See specification sheets for details.) Page 38

39 SECTION III: MOTORIZED EXAM LIGHTING MRS Recommendations for Typical Installation Fixtures placed 4 apart (on centers) to project light on either side of practitioner s head and over practitioner s shoulders. Fixture setback from break in bed determined by ceiling height, and position and height of practitioners. Ideal angle of illumination should be between for sitting practitioners which provides future flexibility should task location change. Consult factory for assistance in determining ideal location of fixtures. Wall control placed in unobstructed location and within line of sight from practitioner's location. Typical Side View: 8 Ceiling Height 8 [244cm] CEILING HEIGHT ANGLE of ILLUMINATION TASK HEIGHT 3 [91cm] LUMINAIRE (ONE SHOWN) 6 7 [201cm] SITE LOW VOLTAGE CABLE 35 [1067cm] WALL CONTROL & BACK BOX SETBACK 3.5 [107cm] Recommended Fixture Setback / Location Sitting Practitioners Photometric testing by ITL (Boulder, CO) ITL Test No Typical Top View: 8 Ceiling Height SPACING (ON CENTER) SITE Ceiling Height Setback from Break in Bed Angle of Illumination Footcandles on Task 4 [122cm] OPTIMAL Alternative SETBACK 6 7 [201cm] OPTIMAL Alternative OPTIMAL Alternative OPTIMAL Alternative Typical Top View: 9' Ceiling Height SPACING (ON CENTER) Sitting Practitioners 4 [122cm] SITE OPTIMAL Alternative setback provided for room configurations that do not allow fixture placement in optimal setback location. For additional setback locations, consult factory. SETBACK 6 7 [201cm] Sitting Practitioners Page 39

40 SECTION III: MOTORIZED EXAM LIGHTING LED Remote Controlled Motorized Recessed Patient Lighting System MRR (Two Light System) MRR (One Light System) FEATURES OPTeCOLOR LEDs deliver up to 10,000 fc with no heat in the beam. OPTeCOLOR LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. Light delivered at angles up to 35 (and 50 with Option -81) to provide full coverage of the patient. Redundancy of controls and electronic components ensures control of fixtures and at least 50% illumination at all times. Fully recessed fixtures with antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. Full control of lighting system (direction, intensity, power) from both remote and wall controls. Independent direction control of each light. Light beams may be aimed at 2 sites or superimposed. Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. Kirlin s exclusive three year limited warranty (one year remote control). APPLICATIONS ICU CCU ED NICU/PICU PATIENT ROOM CATH LAB IP65 POPULAR OPTIONS Input Power V (50-60Hz) input and thermal protector /120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory /120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load. Page 40 Color Temperature (CCT) -41K 4100 K instead of 3500 K. 95+ CRI. -50K 5000 K instead of 3500 K. 95+ CRI. Trim -32 White oversize trim ring. Specify O.D. -94 Custom color self-flanged flare trim instead. Consult factory. -IP IP65 rated trim and lens. Other bottom pan achieves 50 high angle illumination in one direction. Maximum recessed depth 15-1/ Custom length (> 35 feet) plenum rated wall control cables (4). Specify length.-99 Special modification. Consult factory. -BI Beeper (remote control) inactivated by factory. -RC -RS -SE Extra remote control. Remote infrared sensor with 35 cable. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes. (See specification sheets for details.)

41 SECTION III: MOTORIZED EXAM LIGHTING Typical Side View: MRR in Patient Room Typical Side View: MRR in NICU LUMINAIRES 4 [112cm] CONTROL CABLE 35 [1067cm] 4 [112cm] 2 8 [81cm] 22 (35 Max) WALL CONTROL & BACK BOX 23 (35 Max) 30 8 [244cm] SITE 8 [244cm] 3 [91cm] 3 6 [107cm] 3 6 [107cm] 3 4 [101cm] Typical Side View: MRR in Patient Room Front View Side View LUMINAIRE CONTROL CABLES 35 [1067cm] WALL CONTROL & BACK BOX 8 [244cm] SITE 3 [91cm] 3.5 [107cm] Footcandle Distribution Data: MRR (Two Light System) 4' Spacing Photometric testing by ITL (Boulder, CO) I.T.L. Test No ' Ceiling: 3' Work Plane 8990 fc 3' Work Plane 6670 fc 3' Work Plane 5110 fc 9' Ceiling: 10' Ceiling: 3'4" Work Plane fc 3'4" Work Plane 7330 fc 3'4" Work Plane 5570 fc Footcandle Distribution Data: MRR (One Light System) ' Ceiling: 3' Work Plane 5610 fc 3' Work Plane 3900 fc 3' Work Plane 2870 fc 9' Ceiling: 10' Ceiling: 3'4" Work Plane 6420 fc 3'4" Work Plane 4370 fc 3'4" Work Plane 3160 fc Page 41

42 SECTION III: MOTORIZED EXAM LIGHTING LED Motorized High CRI / R9 Recessed Patient Lighting System MRR (Two Light System) MRR (One Light System) FEATURES MRR MRR OPTeCOLOR LEDs deliver up to 10,000 fc with no heat in the beam. OPTeCOLOR LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, red tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. Light delivered at angles up to 35 (and 50 with Option -81) to provide full coverage of the patient. One hand operation of controls: joystick for direction; slide dimmer for intensity (100-10%); push button for power on-off. Independent direction control of each light. Light beams may be aimed at 2 sites or superimposed. Fully recessed fixtures with antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. Kirlin s exclusive three year limited warranty (one year remote control). APPLICATIONS ICU CCU ED NICU/PICU PATIENT ROOM CATH LAB IP IES Progress Report Selection POPULAR OPTIONS Input Power V (50-60Hz) input and thermal protector /120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory /120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load. Color Temperature (CCT) -41K 4100 K instead of 3500 K. 95+ CRI. -50K 5000 K instead of 3500 K. 95+ CRI. Trim and Other -32 White oversize trim ring. Specify O.D bottom pan achieves 50 high angle illumination in one direction. Maximum recessed depth 15-1/8". -87 Custom length (> 35 feet) plenum rated wall control cables (4). Specify length in feet. -94 Custom color self-flanged flare trim instead. Consult factory. -99 Special modification. Consult factory. -IP -SE IP65 rated trim and lens. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes. Consult factory. (See specification sheets for details.) Page 42

43 SECTION III: MOTORIZED EXAM LIGHTING Typical Side View: MRR in Patient Room Typical Side View: MRR in NICU LUMINAIRES 4 [112cm] CONTROL CABLE 35 [1067cm] 4 [112cm] 2 8 [81cm] 22 (35 Max) WALL CONTROL & BACK BOX 23 (35 Max) 30 8 [244cm] SITE 8 [244cm] 3 [91cm] 3 6 [107cm] 3 6 [107cm] 3 4 [101cm] Typical Side View: MRR in Patient Room Front View Side View LUMINAIRE CONTROL CABLES 35 [1067cm] WALL CONTROL & BACK BOX 8 [244cm] SITE 3 [91cm] 3.5 [107cm] Footcandle Distribution Data: MRR (Two Light System) 4' Spacing Photometric testing by I.T.L. (Boulder, CO) I.T.L. Test No ' Ceiling: 3' Work Plane 8990 fc 3' Work Plane 6670 fc 3' Work Plane 5110 fc 9' Ceiling: 10' Ceiling: 3'4" Work Plane fc 3'4" Work Plane 7330 fc 3'4" Work Plane 5570 fc Footcandle Distribution Data: MRR (One Light System) ' Ceiling: 3' Work Plane 5610 fc 3' Work Plane 3900 fc 3' Work Plane 2870 fc 9' Ceiling: 10' Ceiling: 3'4" Work Plane 6420 fc 3'4" Work Plane 4370 fc 3'4" Work Plane 3160 fc Page 43

44 SECTION IV: SHOWER LIGHTS (RECESSED DEADFRONT) A SAFER ENVIRONMENT Dead-front electrically non-conductive trims standard. Higher light levels provided, ensuring effective patient bathing and shower cleaning/maintenance. Impact resistant lenses and reinforced trims provide safety for patient and staff. Fully gasketed trims reduce moisture intrusion into recessed housing. DESIGNED SPECIFICALLY FOR THE DEMANDS OF SHOWERS Corrosion resistant all-aluminum construction results in components operating 25% cooler, extending every component life by 50%. KIRLIN exclusive acrylic enamel finish protects aluminum from corrosion and exceeds ASTM 1000 hour salt spray test. LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. Shallow and super shallow housings for easier installation in crowded plenums. IP65 IP65 trims protect against pathogens passing through the trim, either into the plenum or into the room environment. DEPENDABILITY and REDUCED OPERATING COSTS Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. Power consumption is reduced by up to 80% over traditional light sources Fully sustainable. Modular internal components are visible and easily accessed through the aperture of the fixture. Replacement components are available years into the future. ARRA QUALIFIED Page 44

45 SECTION IV: SHOWER LIGHTS (RECESSED DEADFRONT) Design Function Aperture Product # Performance Lumens Watts Page Flare Regressed Lens Downlight 4 MRR L MRR L Flare Regressed Lens Downlight 6 MRR L MRR L Flare Regressed Lens Downlight 6 MRR L MRV L IP65 Tamper Resistant Downlight 7 MRV L MRV L Flare Super Shallow Downlight 4 MRR L MRR L MRR L Flare Super Shallow Downlight 5 MRR L MRR L Drop Polycarbonate Trim Downlight 5 MRR L MRR L Drop Polycarbonate Trim Downlight 5 MRR L OPTIONS / LUMINAIRE ORDERING 47 PLEASE VISIT FOR KIRLIN COMPACT FLUORESCENT AND INCANDESCENT SHOWER LIGHTS IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). ALL KIRLIN SHOWER LIGHTS ARE U.L. LISTED WET LOCATIONS Page 45

46 SECTION IV: SHOWER LIGHTS FLARE REGRESSED LENS 4 MRR L 6 MRR L MRR L MRR L 6 MRR L 2405 LUMENS 35W MFL (STD) SC: LPW: LUMENS Cone of Light -SPT -WFL Lm: 2568 SC: 0.3 Lm: 1985 SC: 0.9 Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1344 Lm: 1249 SC: 0.4 SC: LUMENS Cone of Light -NFL -WFL 35W MFL (STD) SC: LPW: Lm: 2642 Lm: 2473 SC: 0.4 SC: 1.2 IP65 & TAMPER RESISTANT REGRESSED LENS 7 MRV L MRV L MRV L 1146 LUMENS Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1197 Lm: 1138 SC: 0.4 SC: 1.1 SUPER SHALLOW FLARE REGRESSED LENS Page 46 4 MRR L MRR L MRR L 6 MRR L 1366 LUMENS Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1410 Lm: 1079 SC: 0.4 SC: LUMENS Cone of Light 35W MFL SC: LPW:

47 SECTION IV: SHOWER LIGHTS DROP POLYCARBONATE TRIM 5 MRR L MRR L MRR L 799 LUMENS 15W MFL SC: LPW: Cone of Light 5 MRR L 1650 LUMENS Cone of Light 35W WFL SC: LPW: POPULAR OPTIONS Input Power V (50-60Hz) input and thermal protector V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory. LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter. 85% of rated lumens for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60Hz input only. Specify voltage. Not for use with Option EM INTERNAL emergency inverter. Delivers 500 lumens. Run time: 90+ minutes. -EMH INTERNAL emergency inverter. Delivers 1000 lumens. Run time: 90+ minutes. Color (CCT and CRI) -27K Color temperature 2700 K instead. -30K Color temperature 3000 K instead. -41K Color temperature 4100 K instead. -HC 90+ CRI instead or 3000 K only. Reduces output by ~15%. Optics -NFL Narrow flood distribution instead. -WFL Wide flood distribution instead. Lenses and Trims -13 Clear poly lens below standard lens. Photometric distribution is unaffected. -18 Flat opal glass lens instead. -21 White translucent flat poly diffuser instead. -23 Frosted microprismatic lens instead. -32 White oversize trim ring. Specify O.D. -94 Custom color/finish. Specify. Consult factory. -CF Custom color filter (Rosco). Specify. -WA White acrylic (flat) diffuser instead. Other -79 Extension collar for ceilings up to 2-5/8 thick. -99 Special modification. Consult factory. -FS In-line fusing. -SH Sealed housing and junction box. (See specification sheets for details.) LUMINAIRE ORDERING EXAMPLE MUST SPECIFY OPTIONAL Product Number Voltage Options MRR L MRR L MRR L -120 (120 volts) -277 (277 volts) -97 (Specify other) See Options above Ordering Example: MRR L WFL LUMEN SERIES AVAILABLE Lumen Series Code Nominal Lumens -2500L 2500 Lumens -1500L 1500 Lumens -1000L 1000 Lumens -500L 500 Lumens Page 47

48 SECTION V: GENERAL AND CLINICAL SPACE LIGHTING KIRLIN QUALITY & VALUE THROUGHOUT Inconspicuous downlights with matching wall washes in round and square designs are available in four distributions from spot (-SPT) to wide flood (-WFL) and many color temperatures. Super Shallow downlights offer uniform illumination scaled down to fit in healthcare facilities crowded plenums. IP65 rated and ISO 5 Class 100 Cleanroom luminaires provide protection against infection while maintaining a sophisticated architectural aesthetic from various apertures with matching LookALike regressed lens trims. LEVEL 2 PROTECTION IP65 (SEALED TRIM) LEVEL 2 + PROTECTION IP65 (SEALED TRIM) AND TAMPER RESISTANT IP65 IP 65 VR LEVEL 3 PROTECTION CLASS 100 (SEALED FIXTURE) IP65 CLASS ISO CLEANROOM SECTION V: GENERAL AND CLINICAL SPACE LIGHTING DOWNLIGHTING AND WALL WASHING: ROUND AND SQUARE Function Application Aperture Product # Performance Lumens Watts Page Downlight Open Appearance Nurse Station Admissions 4 MRR L MRR L MRR L Wall Wash Open Appearance Downlight Open Appearance Lobby Cafeteria Conference Room Waiting Room 4 4 MRR L MRR L MRR L MRS L MRS L MRS L Wall Wash Open Appearance Corridor Auditorium 4 MRS L MRS L MRS L Page 48

49 SECTION V: GENERAL AND CLINICAL SPACE LIGHTING DOWNLIGHTING AND WALL WASHING Function Application Aperture Product # Performance Lumens Watts Page Downlight Open Appearance Wall Wash Open Appearance Conference Room Lobby Hallway Registration 6 6 MRR L MRR L MRR L MRR L MRR L Downlight Regressed Lens Dining Room Auditorium 6 MRR L MRR L MRR L Downlight Super Shallow Canopy Nurse Station 4 MRR L MRR L MRR L Downlight Super Shallow Entrance Kitchen 5 MRR L LEVEL 2: IP65 RATED AND BIOGARD ANTIMICROBIAL TRIM Downlight IP65 Rated Soffit Locker Room 7 MRR L Downlight IP65 Rated Wet Location Canopy 8 MRR L MRR L MRR L LEVEL 2 + IP65 RATED, BIOGARD ANTIMICROBIAL AND VANDAL RESISTANT TRIM Downlight IP65 Tamper Resistant Downlight IP65 Tamper Resistant Psychiatric ED Psychiatric Trauma 7 MRV L MRV L MRV L MRV L LEVEL 3: CLEANROOM (ISO 5 CLASS 100) SEALED LUMINAIRE Downlight Cleanroom Downlight Cleanroom Operating Room ICU / NICU / PICU Hybrid OR Operating Room 7 MRR L MRR L MRR L POPULAR OPTIONS AND LUMINAIRE ORDERING 53 PLEASE VISIT FOR: KIRLIN MEDICAL LIGHTING PRODUCTS WITH OTHER LIGHT SOURCES IN KIRLIN S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC) AND KIRLIN S COMPLETE COLLECTION OF LED LUMINAIRES IN KIRLIN S LATITUDES LED LIGHTING CATALOG (BULLETIN 15/16LED). Page 49

50 SECTION V: GENERAL AND CLINICAL SPACE LIGHTING Downlight 4 MRR L MRR L MRR L 1221 LUMENS 15W MFL (STD) SC: LPW: Cone of Light -SPT -NFL -WFL Lm: 1336 SC: 0.4 Lm: 1250 SC: 0.5 Lm: 968 SC: Wall Wash MRR L MRR L MRR L 1035 LUMENS 15W LPW: Square Downlight 4 MRS L MRS L MRS L 1270 LUMENS 15W MFL (STD) SC: LPW: Cone of Light -SPT -NFL -WFL Lm: 1312 SC: 0.3 Lm: 1309 SC: 0.4 Lm: 1068 SC: 1.0 Square Wall Wash 4 MRS L MRS L MRS L 1151 LUMENS 15W LPW: Downlight 6 MRR L MRR L MRR L 4733 LUMENS 55W MFL (STD) SC: LPW: Cone of Light -SPT -NFL -WFL Lm: 4797 SC: 0.3 Lm: 4879 SC: 0.4 Lm: 4070 SC: Wall Wash MRR L MRR L 2883 LUMENS 42W LPW: Cone of Light Key Ft. Distance from fixture FC Footcandles at nadir (0 ) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir. Page 50

51 SECTION V: GENERAL AND CLINICAL SPACE LIGHTING Downlight 6 MRR L MRR L MRR L 4803 LUMENS 55W MFL (STD) SC: LPW: Cone of Light -NFL -WFL Lm: 5058 SC: 0.4 Lm: 4405 SC: 0.8 Super Shallow Downlights 4 MRR L MRR L MRR L 5 MRR L FLARE TRIM FLAT TRIM 1366 LUMENS Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1410 Lm: 1079 SC: 0.4 SC: LUMENS Cone of Light 35W WFL SC: LPW: Cone of Light Key Ft. Distance from fixture FC Footcandles at nadir (0 ) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir. LEVEL 2 PROTECTION IP65 (SEALED TRIM) IP 65 IP65 Downlights 7 MRR L 8 MRR L MRR L MRR L 1327 LUMENS Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1317 Lm: 1187 SC: 0.5 SC: LUMENS Cone of Light -NFL -WFL 55W MFL (STD) SC: LPW: Lm: 5293 Lm: 4487 SC: 0.4 SC: Page 51

52 SECTION V: GENERAL AND CLINICAL SPACES IP65 VR IP65 and Tamper Resistant Downlights 7 MRV L 8 MRV L MRV L MRV L 1146 LUMENS 15W MFL (STD) SC: LPW: LUMENS Cone of Light -NFL -WFL Lm: 1197 SC: 0.4 Lm: 1138 SC: 1.1 Cone of Light -NFL -WFL 55W MFL (STD) SC: LPW: Lm: 4787 Lm: 4046 SC: 0.4 SC: 1.0 LEVEL 3 PROTECTION CLASS 100 (SEALED FIXTURE) IP65 CLASS ISO CLEANROOM 7 Cleanroom Rated Downlights MRR L 8 MRR L MRR L MRR L 2013 IES Progress Report Selection Cone of Light -NFL -WFL 15W MFL (STD) SC: LPW: Lm: 1317 Lm: 1187 SC: 0.5 SC: LUMENS 5229 LUMENS Cone of Light -NFL -WFL 55W MFL (STD) SC: LPW: Lm: 5293 Lm: 4487 SC: 0.4 SC: 0.9 Page 52

53 SECTION V: GENERAL AND CLINICAL SPACES OPTIONS Input Power V (50-60Hz) input and thermal protector V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory. LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L, 85% for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply driver or with Option EM INTERNAL emergency inverter. Delivers 500 lumens. Run time: 90+ minutes. -EMH INTERNAL emergency inverter. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply driver (instead of standard internal driver), sold separately. Drives up to (12) -1500L luminaires or consult factory. Order LPS-1220A (0-10V analog) for 100-1% PWM dimming. See LPS-1220A specification sheet at Color (CCT and CRI) -27K Color temperature 2700 K instead. -30K Color temperature 3000 K instead. -41K Color temperature 4100 K instead. -HC 90+ CRI instead or 3000 K only. Reduces output by ~15%. Optics (-MFL Standard) -NFL Narrow flood distribution. (0.5 SC) -SPT Spot distribution. (0.4 SC) -WFL Wide flood distribution. (1.0 SC) Lenses and Trims -13 Clear poly lens below standard lens. Photometric distribution is unaffected. -17 Prismatic high strength acrylic lens instead. -18 White flat opal glass lens instead. -21 White translucent flat poly diffuser instead. -23 Frosted microprismatic lens instead. -30 All white acrylic enameled cone. -31 White acrylic enameled flange. -32 White oversize trim ring. Specify O.D. -35F Natural aluminum (silver) acrylic enameled flange. -38F Black acrylic enameled flange. -35T Natural aluminum acrylic (silver) enameled trim. -38T Black acrylic enameled trim. -70 SofTex Clear self-flanged cone. (CP x.93) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin white (only) trim finish. -CF Custom color filter (Rosco). Specify. -DF Electrically isolated dead front gasketed trim. -WA White acrylic (flat) diffuser instead. Filter -GE Green acrylic filter mounted in lens assembly. -XF Custom filter mounted in lens assembly. Specify. Other -79 Extension collar for ceilings up to 2 thick. -99 Special modification. Consult factory. -FD Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. -FS In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead. -SH Sealed housing and junction box. (See specification sheets for details.) LUMINAIRE ORDERING EXAMPLE MUST SPECIFY OPTIONAL Product Number Voltage Options MRR L MRR L MRR L -120 (120 volts) -277 (277 volts) -97 (Specify other) See Options above Ordering Example: MRR L K-NFL LUMEN SERIES AVAILABLE Lumen Series Code Nominal Lumens -5000L 5000 Lumens -3500L 3500 Lumens -2500L 2500 Lumens -1500L 1500 Lumens -1000L 1000 Lumens -500L 500 Lumens Page 53

54 SECTION VI: NIGHTLIGHTS, STEPLIGHTS & CHART LIGHTS The most comprehensive collection of nightlights, steplights, chart lights and options available. Full spectrum of optional colors, including Red/Amber (Option -RA) to maintain melatonin levels and circadian rhythm. Fastener-free er-f ree faceplate ate (Option -FF) available on most models. Double faced (thru-the-wall) nightlight illuminates two adjoining spaces. Adjustable to fit various wall thicknesses. Lenses optional instead of louvers. Applications: Patient Room / Patient Room Corridor / Patient Room Bathroom / Patient Room Maximum security nightlight. Optional tamper resistant designs (Option -26) available on most other models. Applications: Public spaces and psychiatric wards. Page 54

55 SECTION VI: NIGHTLIGHTS, STEPLIGHTS & CHART LIGHTS Design Function Aperture Product # Watts Page NIGHTLIGHTS Round Lensed Nightlight 5 MNR Square Lensed Nightlight 5 x 5 MNS Rectangle Lensed Nightlight 3 x 5 MNT Bricklight Louvered Nightlight 3 x 8 MNT Single Face Louvered Nightlight 7 x 10 MNT Double Face Louvered Nightlight 7 x 10 MNT Maximum Security Louvered Nightlight 7 x 9 MNV STEPLIGHTS AND CHART LIGHTS 58 Round Lensed Step/Chart Light 5 MNR Square Lensed Step/Chart Light 5 x 5 MNS Rectangle Lensed Step/Chart Light 3 x 5 MNT Bricklight Louvered Step/Chart Light 3 x 8 MNT POPULAR OPTIONS AND LUMINAIRE ORDERING 59 Page 55

56 SECTION VI: NIGHTLIGHTS 5 Popular Trim Options Fastener Free Face Option Code -FF Tamper Resistant Fasteners -26 MNR x 5 Lensed Popular Trim Options Fastener Free Face Option Code -FF Tamper Resistant Fasteners -26 MNS x 5 Popular Trim Options Option Code Tamper Resistant Fasteners -26 MNT x 8 Popular Trim Options Option Code Tamper Resistant Fasteners -26 MNT Page 56

57 SECTION VI: NIGHTLIGHTS 7 x 10 Popular Trim Options Option Code Prismatic Lens Instead -17 Tamper Resistant Fasteners -26 On-Off Switch -34 GFCI Outlet -GF MNT x 10 MNT Popular Trim Options Option Code Tamper Resistant Fasteners -26 Prismatic Lens on One Side Louver on Other Side Prismatic Lens on Both Sides On-Off Switch on One Side On-Off Switch on Both Sides -L1 -L2 -S1 -S2 GFCI Outlet on One Side -G1 GFCI Outlet on Both Sides -G2 NIGHTLIGHTS - MAXIMUM SECURITY 7 x 9 Popular Trim Options Dual Lens - Polycarbonate Lens Plus High Strength Acrylic Prismatic Lens Instead Option Code -17 MNV Page 57

58 SECTION VI: STEPLIGHTS AND CHART LIGHTS 5 Popular Trim Options Fastener Free Face Option Code -FF Tamper Resistant Fasteners -26 MNR x 5 Popular Trim Options Fastener Free Face Option Code -FF Tamper Resistant Fasteners -26 Lensed MNS x 5 Popular Trim Options Option Code Tamper Resistant Fasteners -26 MNT x 8 Popular Trim Options Option Code Tamper Resistant Fasteners -26 MNT Page 58

59 SECTION VI: NIGHTLIGHT, STEPLIGHT & CHART LIGHT OPTIONS Input Power/ Battery Pack -97 Other voltage input. Consult factory V (50-60Hz) input. Required for Options -34, -GF or -HD. -EI Remote emergency inverter for 100% of rated lumens. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. -HW Higher light output. Approximately doubles light output. Filter Colors -BL Blue filter. -GE Green filter. -OR Orange filter. -RA Red/Amber filter. -YE Yellow filter. -CF Custom color filter (Rosco). Specify. Lenses and Trims high strength prismatic acrylic lens with door instead of louvers. For MNV clear polycarbonate with.187 high strength acrylic prismatic lensed faceplate instead. -26 Faceplate secured to housing with two center pin tamper resistant screws. Tamper resistant tool included. -34 With hospital grade push button on-off switch. Indoor use. Rated 120V only. Must add Option G1 With duplex hospital grade GFCI installed on one side. White. Indoor use. Rated 120V only. Must add Option G2 With duplex hospital grade GFCI installed on both sides. White. Indoor use. Rated 120V only. Must add Option GF With duplex hospital grade GFCI installed. Indoor use. Rated 120V only. Must add Option H1 With duplex hospital grade receptacle on one side. White. Indoor use. Rated 120V only. Must add Option H2 With duplex hospital grade receptacle on both sides. White. Indoor use. Rated 120V only. Must add Option HD With duplex hospital grade receptacle installed. Indoor use. Rated 120V only. Must add Option L1.187 high strength acrylic prismatic lens and door instead on one side. Louvers on other side. -L2.187 high strength acrylic prismatic lens and door instead on both sides. -S1 With hospital grade push button on-off switch installed on one side. Controls both lamps. Indoor use. Rated 120V only. Must add Option S2 With one hospital grade push button on-off switch installed on each side. Controls each side separately. Use with -84. Indoor use. Rated 120V only. Must add Option Faceplate Finishes -35 Natural aluminum (silver) acrylic enamel. -37 Dark Bronze acrylic enamel. -38 Black acrylic enamel. -94 Custom color/finish. Specify. Consult factory. Other -84 Wired for two circuits. -99 Special modification. Consult factory. -FF Fastener free faceplate / trim. No visible hardware. (UL Damp listed only) OPTIONAL FILTER COLORS Circadian Red / Amber Option -RA Tiger Orange Option -OR Wolverine Maize Option -YE Spartan Green Option -GE Lion Blue Option -BL Custom Color Filter Option -CF (See specification sheets for details.) NIGHTLIGHTS, STEPLIGHTS & CHART LIGHTS: ORDERING MUST SPECIFY OPTIONAL Product Number Voltage Options MNT (120 volts) -97 (Specify other) See Options above Ordering Example: MNT GF Page 59

60 1970 s 1990 s s 2000 s launched, ARRA QUALIFIED COMPLIANT and Assembled in the United States of America

SmartLED MRI Lighting Systems

SmartLED MRI Lighting Systems Since 1895 KIRLIN Innovating Design and Performance Bulletin 13LED-MRI-3 SmartLED MRI Lighting Systems The Turnkey Quality Solution from Kirlin Recipients of 2011 Architectural SSL Product Innovation and

More information

Ceramic Metal Halide Lighting

Ceramic Metal Halide Lighting Since 1895 Bulletin 13CMH2 Innovating Design and Performance Ceramic Metal Halide Lighting JW Marriott Grand Rapids, MI. Luminaires by Kirlin. Gary Steffy Lighting Design, Adjustables, Wall Washes Recessed

More information

T4 T4.5 T6 Ceramic Metal Halide Lighting

T4 T4.5 T6 Ceramic Metal Halide Lighting Since 1895 Bulletin 13CMH2 Innovating Design and Performance T4 T4.5 T6 Ceramic Metal Halide Lighting JW Marriott Grand Rapids, MI. Luminaires by Kirlin. Gary Steffy Lighting Design SPOT NARROW FLOOD MEDIUM

More information

THE KIRLIN COMPANY 3401 EAST JEFFERSON AVENUE FAX: LIGHT SYSTEM 1 LIGHT SYSTEM

THE KIRLIN COMPANY 3401 EAST JEFFERSON AVENUE FAX: LIGHT SYSTEM 1 LIGHT SYSTEM lighting since 1895 THE KIRLIN COMPANY 3401 EAST JEFFERSON AVENUE 313-259-6400 FAX: 313-259-9409 www.kirlinlighting.com Remote Controlled High Angle 60 Adjustable Lighting: INFRALITE 60 2 LIGHT SYSTEM

More information

Luminaire. CANOPY: Spun aluminum canopy with silver finish. Available in flat or round. CORD: 96" standard, custom length available to up to 120".

Luminaire. CANOPY: Spun aluminum canopy with silver finish. Available in flat or round. CORD: 96 standard, custom length available to up to 120. PRODUCT SPECIFICATIONS Luminaire PENDANT: Extruded aluminum body with silver powder coat finish. Spun aluminum ring with silver powder coat finish. White frosted glass dome. Optional partially frosted

More information

Luminaire. CANOPY: Spun aluminum canopy with silver finish. Available in flat or round.

Luminaire. CANOPY: Spun aluminum canopy with silver finish. Available in flat or round. PRODUCT SPECIFICATIONS Luminaire PENDANT: Extruded aluminum body with silver powder coat finish. Spun aluminum ring with silver powder coat finish. White frosted glass dome. Optional partially frosted

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ PRODUCT DESCRIPTION Recessed adjustable LED luminaire produces up to 000 delivered lumens. Fixture has 50 visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum

More information

Supporting Healthcare Professionals While Enhancing the Patient Experience

Supporting Healthcare Professionals While Enhancing the Patient Experience Multi- Healthcare Luminaire Supporting Healthcare Professionals While Enhancing the Patient Experience A multi-functional LED luminaire that supports the demands of healthcare environments by improving

More information

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L PRODUCT DESCRIPTION Recessed adjustable 0W LED luminaire produces up to 000 fixture lumens (depending on trim) and approximates the performance of a 75W MR6 lamp. Fixture has 50 visual cutoff and features

More information

Skyline Series. Overbed LED Light. Multiple Directional Light Configurations. 1 Amico Lights Corporation

Skyline Series. Overbed LED Light. Multiple Directional Light Configurations. 1 Amico Lights Corporation Lighting Solutions Skyline Series Overbed LED Light Inspired by the aerodynamic shape of an airplane wing, the Amico Skyline Series Overbed LED Light offers a sleek and elegant design that meets the needs

More information

Drywall with Plaster and Paint. Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. (2x2.5WDC) (2x5WDC) (2x6WDC)

Drywall with Plaster and Paint. Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. (2x2.5WDC) (2x5WDC) (2x6WDC) Drywall Drywall with Plaster and Paint 3.73" (9.5cm) 1" (2.5cm) 6" (15.2cm) 1'- 40' (30.5cm - 1219.2cm) Description: TruLine 1.6A, a versatile 24VDC linear plaster-in LED system, creates glare-free, indoor

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR PRODUCT DESCRIPTION Recessed adjustable LED remodel luminaire produces up to 00 delivered lumens. Fixture has 50 visual cutoff. Low profile housing is available in both IC and Non-IC rated configurations.

More information

BLACK BODY DIMMING & TUNABLE WHITE 1000 LUMEN ADJUSTABLE, DOWNLIGHT AND WALL WASH LED ROUND APERTURE IC410T, TC410T P1.16.0

BLACK BODY DIMMING & TUNABLE WHITE 1000 LUMEN ADJUSTABLE, DOWNLIGHT AND WALL WASH LED ROUND APERTURE IC410T, TC410T P1.16.0 PRODUCT DESCRIPTION Recessed LED luminaire compatible with adjustable, downlight and wall wash trims, features both Black Body Dimming and Tunable White technology in a single fixture and delivers up to

More information

Drywall with Plaster and Paint. 6" - 400" (15.2cm cm) Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. per Foot (2.

Drywall with Plaster and Paint. 6 - 400 (15.2cm cm) Lamp: The average LED Life is 50,000 hours. per Foot. per Watt. per Foot (2. TruQuad 1A, 24Vdc Plaster-In LED system Drywall Drywall with Plaster and Paint 6" (15.2cm) 6" (15.2cm) Description: TruQuad 1A, a versatile 24VDC linear plaster-in LED system, creates glare-free, indoor

More information

Lamp: The average LED Life is 50,000 hours. per Foot 2WDC (2.5WDC) per Watt. per Foot 5WDC Lumen values are based on the 3000K LED test.

Lamp: The average LED Life is 50,000 hours. per Foot 2WDC (2.5WDC) per Watt. per Foot 5WDC Lumen values are based on the 3000K LED test. Drywall Drywall with Plaster & Paint 2" (5.1cm) 1" (2.5cm) 6" (15.2cm) 1'- 40' (30.5cm - 1219.2cm) Description: TruLine.5A, a versatile 24VDC linear plaster-in LED system, creates glare-free, indoor architectural

More information

TruLine TruQuad.5A 24VDC - PLASTER-IN LED SYSTEM

TruLine TruQuad.5A 24VDC - PLASTER-IN LED SYSTEM Drywall Drywall with Plaster & Paint 6" (15.2cm) 2.62" (6.7cm) 6" (15.2cm) 2" (5.1cm) 6" - 400" (15.2cm - 1016cm) 6" - 400" (15.2cm - 1016cm) 6" - 400" (15.2cm - 1016cm) 0.63" (1.6cm) DESCRIPTION TruQuad.5A,

More information

6 Gravity LED Downlight

6 Gravity LED Downlight IHOL-6DR / IRD600 6 Gravity LED Downlight 6 7/8 1 1/4 5 1/16 10 7/16 14 9/16 15 1/8 4 1/2 5 7/8 7 Housing Specification: recognized 1 Trim Specification: Ceiling Cut Out: 6 1/2 Catalog Number Delivered

More information

DRD2X & SurfaceFrame Alt/EM Apex Series Shallow Recessed LED Downlight

DRD2X & SurfaceFrame Alt/EM Apex Series Shallow Recessed LED Downlight DRD2X & SurfaceFrame Alt/EM Apex Series Shallow Recessed LED Downlight Project: Product Code: Type: Date: Spec Sheet V- 11.15.18 Maintains all the standard SurfaceFrame ratings Offers enhanced dimming

More information

DCD2 & Commercial Frame Commercial Recessed LED Downlight

DCD2 & Commercial Frame Commercial Recessed LED Downlight DCD2 & Commercial Frame Project: Product Code: Type: Date: Spec Sheet V- 2.06.8 Commercial-grade downlight that complements high ceiling projects 6 application shown Up to 4000 lumens of architectural-grade

More information

LUM-TECH LED Housing Architectural Downlight CONCENTRA. Architectural. Downlight

LUM-TECH LED Housing Architectural Downlight   CONCENTRA. Architectural. Downlight LUM-TECH LED Housing Architectural Downlight CONCENTRA Architectural Downlight CONCENTRA Lighting Company LED DOWNLIGHT DESIGN CONCENTRA LIGHTING COMPANY has been a leading lighting manufacturer, designing,

More information

Starfire LED. Starfire Lighting inc

Starfire LED. Starfire Lighting inc Starfire LED Starfire Lighting inc Starfire End-to-end shadowless lighting Starfire s proprietary EvenGlow system achieves uniform shadowless light output from end-to-end on both standard and custom lengths.

More information

DCD2 & Commercial Frame Commercial Recessed LED Downlight

DCD2 & Commercial Frame Commercial Recessed LED Downlight DCD2 & Commercial Frame Project: Product Code: Type: Date: Spec Sheet V- 2.06.8 Commercial-grade downlight that complements high ceiling projects 6 application shown Up to 4000 lumens of architectural-grade

More information

LOW PROFILE 3-1/4 LED RECESSED ADJUSTABLE, DOWNLIGHT AND WALL WASH 800/1200/1500/2000 LUMEN ROUND APERTURE TC420LP, IC415LP, IC412LP, IC408LP

LOW PROFILE 3-1/4 LED RECESSED ADJUSTABLE, DOWNLIGHT AND WALL WASH 800/1200/1500/2000 LUMEN ROUND APERTURE TC420LP, IC415LP, IC412LP, IC408LP PRODUCT DESCRIPTION Low Profile recessed LED luminaire compatible with downlight, adjustable and wall wash trims, is less than 4 tall and produces up to 000 delivered lumens. Fixture has 45 visual cutoff

More information

Evoke 2.9" HP. 2.9" Round Downlight

Evoke 2.9 HP. 2.9 Round Downlight Evoke.9" HP Downlight Features Evoke.9 LED fixtures are now available with a higher performance LED module providing W, 8W or 0W of lighting power. Featuring the fit, finish and attention to detail of

More information

HIGH PERFORMANCE RECESSED Collection

HIGH PERFORMANCE RECESSED Collection HIGH PERFORMANCE RECESSED Collection Delivering Superior Performance Featuring HPR-LED Luminaires DesignLights Consortium (DLC) Qualified HIGH PERFORMANCE RECESSED Collection Take the first step to sustainability

More information

CRS8 Quick Release 8W LED Gravity-Fit Pendants

CRS8 Quick Release 8W LED Gravity-Fit Pendants Catalog No. CRS8 Quick Release 8W LED Gravity-Fit Pendants Type Project Specifications/Features Fixture High performance, eco-friendly 8W LED pendant delivering 750+ lumens; matching the output and uniformity

More information

PA-UD-1'x4' LED UP&DOWN PANEL Light. Unique 35% uplight & 65% downlight distribution. Project Location. Catalog # Ordering Information

PA-UD-1'x4' LED UP&DOWN PANEL Light. Unique 35% uplight & 65% downlight distribution. Project Location. Catalog # Ordering Information V.1606 PA-UD-1'x4' LED UP&DOWN PANEL Light Unique 35% uplight & 65% downlight distribution The PA-UD-1x4 series architectural suspended Up/Down dimmable LED panel is a commercial pendant fixture utilizing

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 27 = LED 2700K 30 = LED 3000K 35 = LED 3500K 40 = LED 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 27 = LED 2700K 30 = LED 3000K 35 = LED 3500K 40 = LED 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Winter 2012 Winter 2012 LE 2D L 20 i-g 2 h 4 tin 0 g V Ca LE t Dalo Li g ghting Catalog

Winter 2012 Winter 2012 LE 2D L 20 i-g 2 h 4 tin 0 g V Ca LE t Dalo Li g ghting Catalog Winter 2012 Winter 2012 LED 220-240V Lighting LED Catalog Lighting Catalog LOOK TO CREE FOR PROVEN INNOVATION & SUPERIOR VALUE At Cree, customer-driven innovation is nothing new. It has been our constant

More information

Diffuser. Lamp Specification. total wattage. Dimmer. color correction filter 2500K (Very warm) 20 20" Defogger. Square 15" 15.5" (39.

Diffuser. Lamp Specification. total wattage. Dimmer. color correction filter 2500K (Very warm) 20 20 Defogger. Square 15 15.5 (39. The Edge Lighting mirror collection features integrated lighting that complements any bathroom space. The provided 3000K warm white color renders the space and the user in just the right light. Warmer

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

LED T8 Lamp Replacement Dual-Ended Bypass Existing Fluorescent Ballast. RoHS DIMENSIONS

LED T8 Lamp Replacement Dual-Ended Bypass Existing Fluorescent Ballast. RoHS DIMENSIONS DEBP Series LED T8 Replacement Dual-Ended Bypass Existing Fluorescent Ballast Project: Type: Catalog #: STANDARD The DEBP (dual-ended bypass) Series of LED T8 lamps replace conventional fluorescent lamps

More information

R6NC 6" LED Recessed Downlight: Universal New Construction Housing

R6NC 6 LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 6" housing, 6-1/2" aperture. 6-5/8" Ceiling opening. 16 Gauge galvanized steel housing with die-cast aluminum heat sink. Requires minimum 3"

More information

Linear Sign Lighter. LED and fluorescent lighting for signage, displays and architectural accents. Acuity Brands Juno Linear Sign Lighter

Linear Sign Lighter. LED and fluorescent lighting for signage, displays and architectural accents. Acuity Brands Juno Linear Sign Lighter Linear Sign Lighter LED and fluorescent lighting for signage, displays and architectural accents Acuity Brands Juno Linear Sign Lighter I LED fixture has an 80,000 hour rated life with a look that is contemporary

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71" [69mm]

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71 [69mm] DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Complete Product = Frame-in kit + Light engine + Reflector Order each separately. N Non-IC New construction. Z V Dimming L Lutron.

Complete Product = Frame-in kit + Light engine + Reflector Order each separately. N Non-IC New construction. Z V Dimming L Lutron. Downlighting LyteProfile Project: Location: Cat.No: Type: Lamps: Notes: Qty: " Round downlight and Lensed wall wash LyteProfile LED Downlights are designed for new construction and include downlight and

More information

Ambient Indoor.

Ambient Indoor. Ambient Indoor Healthcare Solutions is focused on understanding the needs of patients, medical personnel and the facilities team to create lighting systems that support the healing process. By blending

More information

4" & 6" LED DOWNLIGHT SPECIFICATION GRADE LED RECESSED DOWNLIGHTS

4 & 6 LED DOWNLIGHT SPECIFICATION GRADE LED RECESSED DOWNLIGHTS 4" & 6" LED DOWNLIGHT SPECIFICATION GRADE LED RECESSED DOWNLIGHTS Optically engineered to balance visual comfort while maintaining maximum output Available in New Construction, Insulated Ceiling, Air-Tight

More information

LED Recessed Lighting

LED Recessed Lighting Ivalo Finiré LED Recessed Lighting Guaranteed LED compatibility with standard high quality 1% Lutron dimming and Xicato LEDs IVALO COLLECTION Overview Why Choose LEDs? LEDs make sense for today s applications.

More information

R4NC 4" LED Recessed Downlight: Universal New Construction Housing

R4NC 4 LED Recessed Downlight: Universal New Construction Housing R4NC 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 4" New Construction housing, 4-3/4" aperture; 4-7/8" ceiling opening. 16

More information

Basics Series Retrofit LED. Economical 4", 5" and 6" Downlight Trims

Basics Series Retrofit LED. Economical 4, 5 and 6 Downlight Trims Basics Series Retrofit LED Economical 4", 5" and 6" Downlight Trims Saves up to 85% in energy costs when compared to equivalent incandescent light source 2 Juno Lighting Group Juno Basics Series Retrofit

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR PRODUCT DESCRIPTION Recessed adjustable LED remodel luminaire produces up to 00 delivered lumens. Fixture has 45 visual cutoff. Low profile housing is available in both IC and Non-IC rated configurations.

More information

R4NC 4" LED Recessed Downlight: Universal New Construction Housing

R4NC 4 LED Recessed Downlight: Universal New Construction Housing R4NC 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Housing/Mounting Specification grade 4" New Construction housing, 4-3/4" aperture; 4-7/8" ceiling opening. 16

More information

Novation. LED 3 Shallow Adjustable IC Downlight Cutout: 4 1/8. Project Name: Fixture Type:

Novation. LED 3 Shallow Adjustable IC Downlight Cutout: 4 1/8. Project Name: Fixture Type: DESPTION The Novation shallow downlight has a height of just. inches with an adjustable housing that utilizes a heat pipe module that can tilt up to degrees and rotate a full degrees. SPECIFICATIONS Watts:

More information

Project: Comments: Prepared By: Shallow. Shallow Pinhole. Control. Code Fixture and Trim D3 Fixed, Square. 9 Watts Watts Watts 18

Project: Comments: Prepared By: Shallow. Shallow Pinhole. Control. Code Fixture and Trim D3 Fixed, Square. 9 Watts Watts Watts 18 Project: Comments: Prepared By: Tunable, fixture produces a wide range of 9+ CRI/ R9 whites from 14K-1,K, as well as pastels and saturated colors Closed-loop color point maintenance to

More information

R4NCIE Intellect Enabled 4" LED Recessed Downlight: Universal New Construction Housing

R4NCIE Intellect Enabled 4 LED Recessed Downlight: Universal New Construction Housing R4NCIE Intellect Enabled 4" LED Recessed Downlight: Universal New Construction Housing Specifications/Features Intellect Control Intellect-enabled luminaires integrate occupancy/vacancy sensing and light

More information

MacAdam Steps Colour consistency within 3 MacAdam steps (SDCM).

MacAdam Steps Colour consistency within 3 MacAdam steps (SDCM). Series 4" recessed LED - Integrated COB and driver Project: Type: Catalogue #: Drawn by: Date: The 4" recessed LED series is developed with an integrated COB and built in driver with a choice of two lumen

More information

Novation. LED 3 Shallow Adjustable IC Downlight Cutout: 4 1/8. Project Name: Fixture Type:

Novation. LED 3 Shallow Adjustable IC Downlight Cutout: 4 1/8. Project Name: Fixture Type: DESPTION The Novation shallow downlight has a height of just. inches with an adjustable housing that utilizes a heat pipe module that can tilt up to degrees and rotate a full degrees. SPECIFICATIONS Watts:

More information

QuickShip. Shipping in 48 hours

QuickShip. Shipping in 48 hours Shipping in 48 hours January 2018 The Williams QuickShip program offers a competitive suite of topselling products to support immediate lighting requirements on any job. Shipping within 48 hours, our centrally

More information

RL630-14W-120V-DIM-FL / RL607-14W-120V-DIM-FL Module LED - Elite Lighting Module LED Lighting Component

RL630-14W-120V-DIM-FL / RL607-14W-120V-DIM-FL Module LED - Elite Lighting Module LED Lighting Component RL630-14W-120V-DIM-FL / RL607-14W-120V-DIM-FL Module LED - Elite Lighting Module LED Lighting Component UNIQUELY ENGINEERED FOR NEW AND EXISTING CONSTRUCTION The Elite Module LED has been engineered for

More information

2" LED Downlights and Adjustables. Energy-efficient, discreet aperture, high performance LED lighting

2 LED Downlights and Adjustables. Energy-efficient, discreet aperture, high performance LED lighting 2" LED Downlights and Adjustables Energy-efficient, discreet aperture, high performance LED lighting 2" LED IC-Rated Downlights and Adjustables Big things come in small packages The sophisticated aesthetics

More information

ROUND LIGHTPLANE 1 3D RLP1/3D SURFACE MOUNT

ROUND LIGHTPLANE 1 3D RLP1/3D SURFACE MOUNT ROUND LIGHTPLANE 1 3D RLP1/3D MOUNT STANDARD SIZES 1" Aperture Rotatable light channels available in 2ft. and 4ft. sections Customizable 3D design, tailor-made to illuminate any space LAMPING LED - Single

More information

Dire ct L in e a r L u min a ire s

Dire ct L in e a r L u min a ire s Dire ct L in e a r L u min a ire s w w w. s i m k a r. c o m It s All in the Name. A premium direct luminaire with high-efficiency operation D iscover how attractive high performance architectural lighting

More information

Architectural LED Luminaires for the Sophisticated Lighting Designer. Acuity Brands Indy Designer Series Collection Generation 5

Architectural LED Luminaires for the Sophisticated Lighting Designer. Acuity Brands Indy Designer Series Collection Generation 5 Designer Series Collection Generation 5 Architectural LED Luminaires for the Sophisticated Lighting Designer Acuity Brands Indy Designer Series Collection Generation 5 I II Acuity Brands Indy Designer

More information

ASW with Emergency Battery Backup (EBB)

ASW with Emergency Battery Backup (EBB) Catalog Number: Approvals: ASW - 32 - - NW - - - - EBB - Series # of LEDs Overall Dimensions Driver LED Color Distribution Voltage Mounting Options Finish Accessories Emergency battery Backup (EBB) Details

More information

IL 3525 Series. LED Industrial Lighting. Advantages of IL3525. Application

IL 3525 Series. LED Industrial Lighting. Advantages of IL3525. Application LED Industrial Lighting Advantages of IL3525 Proprietary Reflector and Optics enabling glare-free uniform lighting for all working environments. Eliminating the need for costly and fragile plastic lenses

More information

ROUND LIGHTPLANE 2 RLP2 WALL MOUNT. STANDARD SIZES 2" Diameter Wall-Mounted Luminaires Configurable in individual sections from 1ft. - 8ft.

ROUND LIGHTPLANE 2 RLP2 WALL MOUNT. STANDARD SIZES 2 Diameter Wall-Mounted Luminaires Configurable in individual sections from 1ft. - 8ft. ROUND LIGHTPLANE 2 RLP2 STANDARD SIZES 2" Diameter Wall-Mounted Luminaires Configurable in individual sections from 1ft. - 8ft. LAMPING LED - Direct or Indirect - 80/90 CRI - 3000K/3500K/4000K Output Options:

More information

PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light.

PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light. PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light. LED RECESSED DOWNLIGHTS Cree LED downlights deliver beautiful light with superior color quality and high

More information

ELECTRICAL. Hertz 50/60 Input Current.7 -.3A. -20 C to +45 C Operating Temp. -4 F to +113 F. Power Factor > 0.9 THD. 1.5 (38.1mm)

ELECTRICAL. Hertz 50/60 Input Current.7 -.3A. -20 C to +45 C Operating Temp. -4 F to +113 F. Power Factor > 0.9 THD. 1.5 (38.1mm) LESTRA-18V1 UPLIGHT Lestra-18V1 is a mid-bay fixture that achieves high lumen output levels. Lestra s diffused light is free from shadows and breaks. The fixture has an anodized finish providing excellent

More information

LEDPNL1X4-40W IC RATED FOR INSULATED CEILINGS. 40 Watt 1x4 Ultra-Thin Edge-Lit LED Panel. Project: Type: Catalog #: WARRANTY & LISTINGS FEATURES

LEDPNL1X4-40W IC RATED FOR INSULATED CEILINGS. 40 Watt 1x4 Ultra-Thin Edge-Lit LED Panel. Project: Type: Catalog #: WARRANTY & LISTINGS FEATURES LEDPNL1X4-W Watt 1x4 Ultra-Thin Edge-Lit LED Panel Project: Type: Catalog #: STANDARD DAMP IC RATED FOR INSULATED CEILINGS The ultra-thin, edge-lit LED panel (LEDPNL) series is designed to deliver general

More information

3 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square

3 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square 3 Eco-Downlight Wattage CCT Delivered Lumens Efficacy 13W 13W 21W 21W 21W 2700K 3000K 2700K 3000K 3500K 1000lm 1200lm 1700lm 1850lm 2000lm Lumens will vary depending on optic, finish & trim type 77lpw

More information

Complete product = Fixture kit + Mounting kit (optionl) Fixture comes with standard ceiling mount. M Medium, s.c. W Wide, s.c.

Complete product = Fixture kit + Mounting kit (optionl) Fixture comes with standard ceiling mount. M Medium, s.c. W Wide, s.c. " mm Downlighting Project: Location: Cat.No: Calculite LED " Cylinder Narrow, Medium & Wide beam, ///lm Calculite LED " features an LED array of high brightness white light LEDs. The new LED boards in

More information

Gravity. High Power 4, 6 & 8-Inch Downlighting

Gravity. High Power 4, 6 & 8-Inch Downlighting Gravity High Power 4, 6 & 8-Inch Downlighting Unlimited Capabilities Powerful Performance From beautiful architectural cylinders to precisely tuned wall washers, performance based design is balanced with

More information

FINELITE 10 Year LED Warranty

FINELITE 10 Year LED Warranty 10 Industry Best Year LED Warranty Top Glow Diffuser (Standard) Date Project Type Comments Bottom Glow Diffuser (Shown) DESCRIPTION High Performance 2" aperture Indirect/Direct (HP-2 ID) is a patented,

More information

Catalog Number. Notes

Catalog Number. Notes Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Our recessed LED module is the most economical means to create a well lit environment with exceptional energy efficiency and near zero maintenance.

More information

Small Form Factor. Track & Recessed Multiples

Small Form Factor. Track & Recessed Multiples MX Downlighting, Small Form Factor Pendants, Track & Recessed Multiples Small Aperture Dynamic Solution The MX Family of LED downlighting, pendants, track & recessed multiples is built on an award-winning

More information

Project: Comments: Prepared By: Shallow. Shallow Pinhole. Control. Code Fixture and Trim D3 Fixed, Round. 9 Watts Watts Watts 18

Project: Comments: Prepared By: Shallow. Shallow Pinhole. Control. Code Fixture and Trim D3 Fixed, Round. 9 Watts Watts Watts 18 Project: Comments: Prepared By: Tunable, fixture produces a wide range of 9+ CRI/ R9 whites from 14K-1,K, as well as pastels and saturated colors Static White platform option produces 9+ CRI/R9 whites,

More information

Ivalo Finiré LED Recessed Lighting

Ivalo Finiré LED Recessed Lighting Ivalo Finiré LED Recessed Lighting Guaranteed LED compatibility standard with high-quality 1% Lutron dimming and Xicato LEDs New! Higher Output, up to 2000 lumens Higher efficacy with more light output

More information

MODA MINI COVE INTERIOR DYNAMIC WHITE

MODA MINI COVE INTERIOR DYNAMIC WHITE MODA MINI COVE INTERIOR DYNAMIC WHITE Client: Project Name: MODA Contact: E-Mail: Type: Notes: PO#: Quantity: Miniature Line Voltage Cove Fixture. MODA MINI COVE INTERIOR is an award winning, line voltage,

More information

Halo Commercial HC4 HM PS. Housing Frame. LED Module. Series Reflectors. 4-inch Lens Downlight and Lens Wall Wash

Halo Commercial HC4 HM PS. Housing Frame. LED Module. Series Reflectors. 4-inch Lens Downlight and Lens Wall Wash ESCRIPTION Recessed 4-inch LE downlight provides narrow, medium or wide distribution patterns ideal for general area lighting. Lumen packages range from 1000 to 4000 lumens in color temperatures of 2700K,

More information

QuickShip. Shipping in 48 hours

QuickShip. Shipping in 48 hours Shipping in 48 hours January 2017 The Williams QuickShip program offers a competitive suite of topselling products to support immediate lighting requirements on any job. Shipping within 48 hours, our centrally

More information

ROUND LIGHTPLANE 1 3D

ROUND LIGHTPLANE 1 3D ROUND LIGHTPLANE 1 3D RLP1/3D LED Find additional images and information at www.alwusa.com/product/lightplane-1-round-rlp1-3d PRODUCT SUBMITTAL WORKSHEET 1. BASE MODEL RLP1/3D RLP1/3D/F Page 2 of 10 1"

More information

New Ivalo Finiré LED Recessed Lighting. Works with RadioRA 2, HomeWorks QS, and GRAFIK Eye QS control systems

New Ivalo Finiré LED Recessed Lighting. Works with RadioRA 2, HomeWorks QS, and GRAFIK Eye QS control systems New Ivalo Finiré LED Recessed Lighting Works with RadioRA 2, HomeWorks QS, and GRAFIK Eye QS control systems IVALO COLLECTION LED Recessed Lighting Introducing Finiré Finiré eliminates guesswork by ensuring

More information

Knife-edge interior cove system for interior architecture

Knife-edge interior cove system for interior architecture Description The Light Cut is a linear cove lighting system comprising a knife-edge extruded profile which integrates perfectly in drywall ceilings and moveable spot modules. To achieve more innovative

More information

SPECFIT 9.5" Retrofit Downlight AD9.5 DIM010 UNV ADR9.5. Project: Part#: Type: Ex: AD9.5-LES-9040-DIM010-UNV-MD-ADR9.5-CC

SPECFIT 9.5 Retrofit Downlight AD9.5 DIM010 UNV ADR9.5. Project: Part#: Type: Ex: AD9.5-LES-9040-DIM010-UNV-MD-ADR9.5-CC Project: Part#: Type: SPECFIT 9.5" Retrofit Downlight Mechanical SPECFIT retrofits existing commercial housings. Spring action clips to accommodate ½ to 2 ceiling thicknesses. Fixture with remote driver

More information

Open. Distribution Ratios 20% / 80% 40% / 60%

Open. Distribution Ratios 20% / 80% 40% / 60% 10 Industry Best Year LED Warranty Series 16 LED Indirect/Direct - 2E, 3E, & 4E Date Project Flat Endcap shown Type Comments Extended Endcap Signal White is standard finish DESCRIPTION Series 16 LED is

More information

8.50 (216) Ball Catch Retainers 3.00 (76) Aperture Lens Location .74 (19)

8.50 (216) Ball Catch Retainers 3.00 (76) Aperture Lens Location .74 (19) VF150 Series - 8704 Trim RECESSED RECTANGULAR BEVELED ACCENT 2-LIGHT TRIMMED LED PROJECT TYPE CATALOG NUMBER Measurements in ( ) are metric equivalents. RECTANGULAR BEVELED TRIMMED ACCENT - The VF150 Series

More information

Finiré 3" & 4" LED Recessed Lighting

Finiré 3 & 4 LED Recessed Lighting Finiré 3" & 4" LED Recessed Lighting Luxury LED Recessed Lighting by Ivalo Guaranteed Lutron control compatibility Standard Lutron 1% dimming driver with Soft-on, Fade-to-Black options Industry best 97

More information

WALL HI-OUTPUT. Project. Type. Notes

WALL HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.3 W/ft 96 lm/w 900 lm/ft 9.8 W/ft 92 lm/w 1100 lm/ft 12.5 W/ft 88 lm/w 1 5/8"

More information

1.80 (46) Aperture Lens Location. Ball Catch Retainers

1.80 (46) Aperture Lens Location. Ball Catch Retainers VF150 Series - Trim SQUARE BEVEL ACCENT DOWNLIGHT 1-LIGHT TRIMMED LED PROJECT TYPE CATALOG NUMBER Measurements in ( ) are metric equivalents. SMALL APERTURE SQUARE BEVEL ACCENT - The VF150 Series family

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information

CONTROL BY SAVANT LIGHT BY USAI

CONTROL BY SAVANT LIGHT BY USAI CONTROL BY SAVANT LIGHT BY USAI savant.com 2018 Savant Systems, LLC. All rights reserved. Exclusive TrueImage technology delivers sophisticated lighting control with true-to-life images. Use the Savant

More information

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CHROMAWERX OUTPUT WATTAGE. LED - high performance LED

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CHROMAWERX OUTPUT WATTAGE. LED - high performance LED PROJECT: APPROVED BY: SIGNATURE: Grid - shown with a Nova flat lens Grid - shown with a Nova Slope lens DESCRIPTION Nova is an efficient architectural LED troffer with a distinctive luminous shielding

More information

Evoke 2.9" HP. 2.9" Round Adjustables

Evoke 2.9 HP. 2.9 Round Adjustables Evoke 2.9" HP Adjustable/Adjustable Shower Features Evoke 2.9 ED fixtures are now available with a higher performance ED module providing 11, 18 or 20 of lighting power. Featuring the fit, finish and attention

More information

CALIBER LIGHTING. SERIES 4SQLBV-NF Lumen Bridglux LED Recessed Downlight APPLICATION PRODUCT DATA. Trim Finish. Options

CALIBER LIGHTING. SERIES 4SQLBV-NF Lumen Bridglux LED Recessed Downlight APPLICATION PRODUCT DATA. Trim Finish. Options APPLICATION These high-lumen fixtures are ideally suited for lobbies, auditoriums and many other applications with high ceilings, where superior light output is needed. Multiple beam distributions are

More information

OUTDOOR TRACK (PATENT PENDING)

OUTDOOR TRACK (PATENT PENDING) 1.91" (4.9cm) Micro Track Head Finish Micro Track Head Finish Features & Benefits Offers the flexibility of track lighting in an Exterior environment Uses 12VAC low voltage wiring without the need for

More information

SERIES 6SQLCDB79V Low Voltage LED Downlight

SERIES 6SQLCDB79V Low Voltage LED Downlight APPLICATION Remotely powered fixtures designed specifically for the Trinity systems. For use where access to driver and electrical components may be restricted after installation. Especially useful in

More information

Decorative luminaires for open ceiling commercial and retail applications. Indy Commercial/Retail Lighting

Decorative luminaires for open ceiling commercial and retail applications. Indy Commercial/Retail Lighting Commercial & Retail Lighting Decorative luminaires for open ceiling commercial and retail applications Indy Commercial/Retail Lighting I II Indy Indy Commercial/Retail Lighting Lighting Commercial and

More information

REMEDI. LED Multi-function Bed Light

REMEDI. LED Multi-function Bed Light REMEDI LED Multi-function Bed Light APPLICATIONS PATIENT ROOMS EXAMINATION ROOMS PRE- AND POST-OP AREAS PHYSICIAN S OFFICES CLINICS REMEDI PRODUCT OVERVIEW Remedi blends architectural aesthetics with leading

More information

C2L04LS Calculite 1.75" Aperture, 400 Lumen LED

C2L04LS Calculite 1.75 Aperture, 400 Lumen LED CLLS Calculite." Aperture, Lumen LED Page of 6.6 (standard installation). (if fully extended).8 Top view.6.8..6.86..6 Front view... Side view Ordering Guide: Frame-in Kits Frame-in Kit Series Lumen Package

More information

Catalog # Project. Comments. Prepared by

Catalog # Project. Comments. Prepared by description Recessed 6 inch aperture open wall wash for two horizontal 13W or 18W double twin tube compact fluorescent lamps. Fixture is suitable for commercial construction. Insulation must be kept 3

More information

Material. LED Chip. Mounting. Max Length. Environment. Certifications. Warranty. Dimming. COLOR (K) LUMENS (per ft) EFFICACY (LM/W) CRI/Ra R9 Rf Rg

Material. LED Chip. Mounting. Max Length. Environment. Certifications. Warranty. Dimming. COLOR (K) LUMENS (per ft) EFFICACY (LM/W) CRI/Ra R9 Rf Rg Quantum 2 ANGLED 1005 Description The Quantum 2 ANGLED 1005 Channel is a frosted lensed aluminum channel fixture that is powered by Quantum 2 High Density 08 LED tape light. It is dimmable, surface mountable

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information

INTERNATIONAL PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light.

INTERNATIONAL PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light. INTERNATIONAL PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light. LED RECESSED DOWNLIGHTS Cree LED downlights deliver beautiful light with superior color

More information

Halo Commercial PRS4 SM4 41S 44S. colors. 4-inch Square Lens Downlight and Lens Wall Wash

Halo Commercial PRS4 SM4 41S 44S. colors. 4-inch Square Lens Downlight and Lens Wall Wash ESCRIPTION Recessed 4-inch LE square downlight with field interchangeable optics deliver narrow, medium and wide distribution patterns ideal for general area lighting. Luminaire is airtight and can be

More information

DCC4. Adjustable LED Cylinder JA8. Surface, Cord, Stem, Wall Mount. Precise, 360º adjustability expands the capabilities of DMF s DCC Cylinder

DCC4. Adjustable LED Cylinder JA8. Surface, Cord, Stem, Wall Mount. Precise, 360º adjustability expands the capabilities of DMF s DCC Cylinder Project: Product Code: Type: Date: Spec Sheet V- 12.01.18 Precise, 360º adjustability expands the capabilities of DMF s DCC Cylinder Class leading 45 tilt and 20, 30, or 40 optics put light control at

More information