LASER SCATTERING PARTICLE SIZE DISTRIBUTION ANALYZER LA-910
|
|
- Job Gibbs
- 6 years ago
- Views:
Transcription
1 LASER SCATTERING PARTICLE SIZE DISTRIBUTION ANALYZER LA-910
2 Introducing our latest particle-size distribution analyzer, the ultimate in performance and functional capacity: the brand-new Model LA-910 The fast and flexible LA-910 gives you results in 20 seconds all the way from 0.02 µm to 1,000 µm with no optical changes. A powerful computer provides a convenient operator interface for instrument control, color graphics and data management and retrieval. The rugged dispersant-circulation system and the incredibly stable optical system deliver what you need on the job in a user-friendly package: performance, flexibility and reliability. The flexible LA-910 is designed in anticipation of your growing and ever-varying needs in the future of particle-size distribution analysis. 1
3 From 0.02 µm to 1,000 µm with no optical change The LA-910 uses an optical system especially developed by Horiba. Multiple light sources and a large-diameter lens with low optical aberration enable the LA-910 to measure particle size distribution across the entire range of 0.02 µm to 1,000 µm in 20 seconds with no need to adjust lenses. Even with samples where the distribution range is not known there is no longer any need for range selection. 80 channels of resolution accurate, precise analysis The LA-910 uses an iterative deconvolution method to calculate particle-size distribution. The results of analysis are displayed as histograms with the measurement range divided into 80 segments. This gives a highly resolved view of the size distribution. Now it is easy to identify the peaks in mixed samples with particles of different sizes. 2
4 User-friendly operation under Microsoft Windows TM environment The LA-910 works with Microsoft Windows TM to provide a user-friendly interface. Just point with the mouse at on-screen choices to set the parameters for measurement and display, start sequence of analyses, or retrieve and manipulate data in different formats. 3
5 Scattering pattem Display condition Measurement condition Sequence program Uses Microsoft Windows Environment*. Just point the mouse for easy input Setting the conditions for measurement and display, adjusting the sample, taking measurements, file handling, data output, and more all these operations are handled under the Microsoft Windows environment. This means you can use the mouse for virtually everything on the LA The LA-910 sets up three basic types of application windows for you to work under: Measurement Windows, Sequence Windows, and Utility Window. Microsoft Windows TM version 3.1 The Sample Preparation Unit is controlled automatically for ease in adjusting dilution, dispersion, and more The Sample Preparation Unit has everything you need, including an ultrasonic dispersion bath with stirrer, a flowcell, and a circulating pump. It automatically prepares the sample, stirring and dispersing it in an appropriate fashion, and then performs the measurement. Throughout the measurement, the particles suspended in the sample fluid are automatically maintained at the proper concentration, eliminating measurement errors. Real-time processing of all types of sample data for truly efficient measurements The LA-910 is loaded with an array of sophisticated features as standard equipment. The Scattered-Light Intensity- Distribution/Transmittance Monitor Readout makes it easy to determine the sample density and the scattered light intensity distribution accurately at just a glance. The Quick PSD Readout gives you a fast, precise confirmation of the sample's particle-size distribution including both distribution status and the agglomeration status. All these features and more that process the data for you in real time enable you to make quick, accurate decisions concerning the measurement and dispersion conditions. Much faster and more accurate measurements are now possible than ever before. Condition File simplifies the parameter-setting process Once you have specified the optimum parameters for measurement, display, and other factors for a particular sample, all thes information may be stored in condition file as a retrievable data-set. A data set in condition file may be activated at any time just by pointing the sample I.D. Measurement procedures will be carried out using the exact parameters you had specified previously. This greatly enhances operational efficiency. Also, since the results for particular sample types may be shown using the same specified display format, you are assured of greater stability in repeat measurements. Editing function for one-touch automated measurements This window's editing function is used to customize the meaurement sequence. For example if you want to do completely automated measurements using the optional Auto-Sampler or if you just need quick results for a rouine operation it's easy to edit the sequence for up to 255 steps. System Check Function assures reliability of measurement results Each time the LA-910 unit is turned on, it automatically performs a self-diagnostic system check. Measurements will commence only after it has been determined that the system is in optimum condition. This invaluable function gives you complete assurance in the accuracy of your measurement results. 4
6 Flexible handling of data Not only does the LA-910 allow you to display particle-size distribution data in a variety of formats; it also gives you the flexibility to manipulate and process the data freely. The LA-910 now has the power to meet the most stingent demands for high-level data processing in the laboratory. 10-channel quick memory Up to ten sets of measurement results can be stored in memory by just pointing the mouse. This function offers many important advantages.for example, multiple overlapping particle-size distribution curves may displayed simultaneously. It also permits handy temporary storage of data in the main memory until you are ready to download it on to disks for permanent storage. Built-in text conversion function allows you to process data to meet the needs of each job Conversion to standard ASCII file format is done automatically for easy transporting of data, directly or by modem, to a host computer or LIMS. This function is especially convenient when you need to work directly from your PC to use measurement data, to recompile it, or to develop original data processing programs. Measurement results can easily be transformed into a text file; this means you can directly use your PC's spreadsheet software and graphic processing software to display data gathered by the LA-910. Flexible graphic function allows a variety of display formats, including overlapping curves and expansion of displayed range The Overlap Display allows you to select on-screen display of several different types of particle-size distribution curves. The Expanded Display makes possible the expansion of a desired range of particle diameters within the particlesize distribution graph. Other valuable functions include the ability to set spacing between particular particle diameters and shift the orientation of the graph's axis as needed. All these functions and more give you the flexibility for exactly the type of on-screen presentation you need for each different measurement job. Naturally, hard copies of all display formats can be printed out exactly as they appear onscreen. Overlapping curves Standard displayed range Expansion of displayed range 5
7 Flow Schematics auto sampler (option) dispersant A reservoir unit (option) dispersant B rinsing solution M M P stirrer printer ultrasonic chamber mirror circulation pump He-Ne laser signal selector beam expander tungsten lamp sample flowcell array detector condenser lens A/D converter computer RS-232C CPU 6
8 rear detector side detectors condenser lens ring-type detectors scattered light pattem He-Ne laser beam expander tungsten lamp filter rear detector side detectors sample particle Here is how the LA-910 work Light irradiating the particles is scattered at various angle. If the particles are large, the scattering is concentrated in the forward direction; conversely, if the particles are small, the scattering is in all directions. Therefore, to measure larger particles, data on the scattered light intensity of a small angle is needed; to measure smaller particles, data on the intensity of a large angle is needed. To measure the distribution of small-angle scattered light intensity from the sample particles, the LA-910 uses a condenser lens to condense the light on a ring-type detector. For larger-angle scattered light intensity, detectors are located at the side and rear, as shown. From the angular distribution of the scattered light intensity, the Mie scattering theory is used to calculate the particle-size distribution. In addition, it is known that the shorter the wavelength of the irradiated light, the smaller the diameter becomes of particles that can be measured.asa consequence the LA-910 has expanded the measurable range by using a short wave length tungsten lamp in addition to the He-Ne laser beam. Frequency/cumulative distrbution graph with overlapping curves Frequency/cumulative distrbution graph 7
9 A full range of upgrade options means greater versatility, efficiency, and productivity Automated control and dilution of samples the Reservoir Unit The LA-910 with the Reservoir Unit option automatically injects the right amount of dispersant into the sample until it is diluted to the proper concentration. It employs an auto-cycle (1) agitation, (2) ultra-sonic dispersion, (3)circulation, and (4) measurement. Auto-sampler Continuous, non-stop measurements the Auto-Sampler & the Reservoir Unit A further system upgrade, including both the Auto-Sampler and the Reservoir Unit, can make continuous, non-stop measurements of up to 24 samples, with automatic processing of the resulting data. All you have to do is put in the sample and instruct the instrument to conduct the measurement sequence. This system features streamlined, efficient measuring. Measuring minute samples/retrieving and saving the sample the Fraction Cell & the Cell Holder The LA-910's standard flow-cell measures the sample as it circulates in a liquid state. For samples of costly materials that need to be saved after measurement, use the optional Fraction Cell and Cell Holder. This allows the measurement of minute quantities of sample without loss of the sample material. Precise measurement of dry powders the dry powder feeder A new dry powder feeder easily disperses cohesive samples for precise measurement of dry powders well into the sub-micron range. With the dry powder feeder installed, only the sample cell needs to be changed to convert from wet to dry, or dry to wet, measurement in less than 5 minutes. The dry powder feed system operation is fully controlled from the computer. 8
10 Dimentional Outlines Unit: mm (in) 570 (22.4) SPECIFICATIONS Principles of measurement: Based on Mie scattering theory Range of particle size measured: 0.02 to 1,000 µm Measurement time: Approx. 20 seconds, normally from start of measurement to display of data Amount of sample liquid required for measurement: 10 mg to 1 g per measurement, with 215 to 315 ml of dispersant fluid when using the flow cell This figure depends on the sample Optical system: Light souce: nm He-Ne laser 1mW, Tungsten lamp 50 W Photo-cell detector: 18-division, silicone photo-diode array; and Silicon photo-diode( 6) Sample recirculation system: Mechanical stirrer: Up to 1,000 rpm(for distilled water), 7 speed selections, silicone-tubing Ultrasonic chamber: 40 W, 39 khz Circulation pump: Peristaltic pump, discharge volume 1,000 ml/min.(for distilled water), 7 speed selections, silicone-tubing Sample flow cell: Tempax glass Communications: RS-232C port Operating conditions: 10 (50 F) to 35 C (75 F), less than 85% RH(no condensation) Computer: COMPAQ DESKPRO (Subject to change at discretion of manufacture.) OS: MS-DOS 6.0 Operation interface: TM Microsoft Windows Ver.3.1 Power: 100/120 to 200/220 V to 240 V AC. selectable, 50/60 Hz, approx. 500 VA 320 (12.6) 650 (25.6) Dimentions*: 650(W) 570(D) 320(H)mm 25.6(W) 22.4(D) 12.6(H)inch. Weight*: Approx. 55 kg, 120 lbs ( excluding the computer) Measurement Conditons Agitation speed: 0-1,000 rpm(for distilled water), 7 speed selections between 1 to 7 Ultrasonic working time: 0-30 min, 1.0 min. increment including operation during measurement Waiting time after ultrasonic-preparation: 0, 10, 20, 30, 60 second selectable Circulation speed: 0-1,000 ml/min. (for distilled water), 7 speed selections between 1 to 7 Scanning frequency: 10, 15, 20, 25, 30, 40, 50, 100 times, selectable Calculation: Multiple calculation with 2-types selectable Printout: Automatic or manual, selectable Dilution solution: Up to 250 ml, 10 ml increment(for automatic mode) Rinse amount: Up to 250 ml, 10 ml increment(for automatic mode) Rinse frequency: 1 to 3 times, selectable Data Presentations Computer display: S-VGA color monitor (a) Data (b) Setting of conditions (data display conditons) (c) Scattering light display/sample concentration monitor (d) Measurement data Analysis basic by volume, area, length or particle number Graph segment number 80, logarithmically fixed Particle distribution graph Frecuency distribution graph, percent undersize or percent oversize Particle diameter representation Median diameter % on diameter Diameter on % Mean diameter Standard deviation Mode diameter Span value Coefficient of variation Option a) Reservoir unit(automatic concentration adjustment and rinsing) b) Auto sampler(automatic injection and measurement of up to 24 samples) c) Fraction cell holder with magnetic stirrer d) Fraction cell e) Dry powder feeder F) Application software Please read the operation manual before using this product to assure safe and proper handling of the product. The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. The color of the actual products may differ from the color pictured in this catalog due to printing limitations. HORIBA, Ltd. Head Office Miyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Phone: 81 (75) Fax: 81 (75) Tokyo Sales Office Higashi-Kanda Chiyoda-ku, Tokyo, Japan Phone: 81 (3) Fax: 81 (3) Beijing Representative Office Suite 1409, Tower B, COFCO Plaza, No. 8, Jianguomennei Avenue, Beijing, China, Phone: Fax: Shanghai Representative Office Unit F1 16F Jiushi Fuxing Mansion, No. 918, Huaihai Zhong Road, Shanghai, China, Phone: /90 Fax: Taiwan Representative Office No.15 Alley6, Lane 485, Sec. 1, Kuang Fu Rd., Hsin-Chu, Taiwan, R.O.C. Phone: 886 (3) Fax: 886 (3) Tel : (02) Fax : (02) HORIBA INSTRUMENTS Pte. LTD. 10 Ubi Crescent #05-11/12, Ubi Techpark Singapore Phone: Fax: HORIBA INSTRUMENTS INCORPORATED Irvine Facility Ann Arbor Facility Armstrong Avenue 5900 Hines Drive Irvine, CA 92614, U.S.A. Ann Arbor, MI Phone: 1 (949) U.S.A. Fax: 1 (949) Phone: 1 (734) Fax: 1 (734) HORIBA / STEC INCORPORATED 1080 E. Duane, Suite. A Sunnyvale, CA U.S.A. Phone: 1 (408) Fax: 1 (408) HORIBA GmbH Kaplanstrasse 5 A-3430 Tulln, Austria Phone: 43 (2272) Fax: 43 (2272) HORIBA CZECHIA Organizachi slozka Praha Petrohradska 13 CZ Praha 10, Czech Republic Phone: 420 (2) Fax: 420 (2) HORIBA INSTRUMENTS LIMITED Kyoto Close Summerhouse Road Moulton Park, Northampton NN3 6FL, U.K. Phone: 44 (1604) Fax: 44 (1604) HORIBA EUROPE GmbH Head Office Hauptstrasse 108 D Sulzbach Germany Phone: 49 (6196) Fax: 49 (6196) Leichlingen Facility Julius-kronenberg Strasse D Leichlingen Germany Phone: 49 (2175) Fax: 49 (2175) HORIBA FRANCE Rue L. et A. Lumie `re Technoparc F St-Genis-Pouilly France Phone: 33 (4) Fax: 33 (4) HORIBA SWEDEN Her tig Carlsv ag S So derta lje Sweden Phone: 46 (8) Fax: 46 (8) HORIBA ITALY Europalace Corso Torino 43/ Orbassano,Torino,Italy Phone: 39 (011) Fax: 39 (011) Bulletin : HRE-3630A Printed in Japan ZZ-F(SK)3
Laser scattering particle size distribution analyzer LA-300
Laser scattering particle size distribution analyzer LA-300 The LA-300 Particle Size Analyze You asked for "affordability," "easy use," and "compact size" without compromise in quality, and HORIBA has
More informationDynamic Light Scattering Particle Size Distribution Analyzer LB-500
Dynamic Light Scattering Particle Size Distribution Analyzer LB-500 At Last, Routine Particle Size Distribution Measurement Enters the realm of the Nanometer Horiba has refined its expertise in developing
More informationGLOSS CHECKER USER GUIDE. Handheld Gloss Meter. IG Series. Printed in Japan XX-X(SK)00. Integrated type IG-320. Remote sensor type IG-331
Integrated type The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. The color of the actual products may differ from the color
More informationSemiconductor Manufacturing Process Monitor
Semiconductor Manufacturing Process Monitor OES (Optical Emission Spectroscopy) Etching End-point Monitor Real Time Interferometric Process Monitor DM-1000 series LEM-CT-670-G50 Integrated management with
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 US EDITION The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green laser that
More informationLA-950 Laser Diffraction Analyzer
LA-950 Laser Diffraction Analyzer mark.bumiller@horiba.com Laser Diffraction Particle size 0.01 3000 µm Low End Sensitivity 30, 40, 50, 70 nm latex standards Low End Sensitivity Sensitivity: small particle
More informationGCMS-3 GONIOSPECTROPHOTOMETER SYSTEM
MURAKAMI Color Research Laboratory 11-3 Kachidoki 3-Chome Chuo-Ku Tokyo 104 Japan Tel: +81 3 3532 3011 Fax: +81 3 3532 2056 GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM GSP-1 Main System Overview The colour and
More informationGreen Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500
Green Scan Laser PhotocoagulatorGYC-500 Vixi Green Laser PhotocoagulatorGYC-500 The Small, Incredibly Versatile Green Laser Photocoagulator The GYC-500 Vixi / GYC-500 is a solid state green laser that
More informationUV / VIS Spectrophotometer EMCLAB Instruments GmbH
A Professional Manufacturer UV / VIS Spectrophotometer EMCLAB Instruments GmbH EMCLAB Instruments GmbH Bismarckstrasse 120 47057 Duisburg Germany Phone: +49 203 3064042 Fax: +49 203 3064044 E-mail: info@emc-lab.de
More informationCOFFEE LABORATORY WHITE STONE VA Tel (804)
COFFEE LABORATORY USA FOR THE PARTICLE SIZE ANALYSIS OF COFFEE GROUND COFFEE COFFEE BEAN GRADING CLICK HERE PRODUCT DEMONSTRAION Reference code: OCC63 Occhio Zephyr ESR Particle size range (30 microns
More informationThermo Scientific SPECTRONIC 200 Education
molecular spectroscopy Thermo Scientific SPECTRONIC 200 Education Part of Thermo Fisher Scientific Designed for the Teaching Laboratory Classroom Friendly Sample Compartment Whether you measure in 10 mm
More informationThermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument
Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer The perfect teaching instrument Designed for the Teaching Laboratory Thermo Scientific SPECTRONIC spectrophotometers have served as core analytical
More informationSP-8001 UV/Visible Spectrophotometer
SP-8001 UV/Visible Spectrophotometer Provide Accurate Results High performance UV/Visible Spectrophotometer for Research, and Laboratory work Product Features The Metertech SP-8001 UV/Visible Spectrophotometer
More informationParticle size range (0.8 microns 1000 microns)
Reference code: OCC242-02 Occhio Flowcell FC200 M-HR Particle size range (0.8 microns 1000 microns) Technical specifications Working conditions Working temperature 5-40 C non condensing Power Supply 100-220
More informationQ8384 Q8384. Optical Spectrum Analyzer
Q8384 Optical Spectrum Analyzer Can measure and evaluate ultra high-speed optical DWDM transmission systems, and optical components at high wavelength resolution and high accuracy. New high-end optical
More informationYellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500
Yellow Scan Laser Photocoagulator YLC-500 Vixi Yellow Laser Photocoagulator YLC-500 A 577 nm Yellow Laser with Multiple Scan Patterns The YLC-500 Vixi / YLC-500 is a yellow laser using the innovative OPSL
More informationThermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements
Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer The perfect tool for routine measurements The Standard for Routine Measurements Thermo Scientific SPECTRONIC spectrophotometers have served as
More informationThermo Scientific SPECTRONIC 200
molecular spectroscopy Thermo Scientific SPECTRONIC 200 Part of Thermo Fisher Scientific The New Standard for Routine Measurements Robust, Multifunction Sample Compartment Whether you measure in 10 mm
More informationQAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)
OCCHIO Pharma CLICK FOR PRODUCT DEMO 400 OCCHIO Pharma O. O. O. O. OCCHIO Pharma 4 G 00 NANO OCCHIO 500 Occhio 500nano TECHNICAL DATASHEET Reference code: OCC023 Occhio500nano Technical specifications
More informationSuper High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series
Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series Nikon's proprietary scanning-type optical interference measurement technology achieves 1pm* height resolution. * Height
More informationLumenis Array LaserLink Pattern Scanning Laser Technology RETINA
Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA Array LaserLink Pattern Scanning Laser Technology Pattern Scanning Laser can reduce photocoagulation treatment time by as much as 60% Pattern
More informationMulti-Wavelength Meter AQ6141. Perfect for Wavelength Analysis in DWDM Systems
Multi-Wavelength Meter AQ6141 Perfect for Wavelength Analysis in DWDM Systems Multi-Wavelength Meter AQ6141 Perfect for Wavelength Analysis in Wavelength Division Multiplexing (WDM) transmission enables
More informationA Revolution in Information Management
Conforms to SEMI Standards Upgraded with New Functions Suitable for Reading Dot Cell Codes A Revolution in Information Management Actual size Industry's smallest head (without lens) V530-R150E-2, V530-R150EP-2
More informationL100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION
L100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION It s a Nikon... The L100 CMM laser scanner offers the best possible combination of speed,
More informationLM-1200 / 1000(P) AUTO LENSMETER
LM-1200 / 1000(P) AUTO LENSMETER LM-1200 / 1000(P) Auto Lensmeters Advanced & Dynamic Technologies Provide for Faster, Easier and More Accurate Measurement Faster & Easier for Progressive Power Lenses
More informationCoherent Laser Measurement and Control Beam Diagnostics
Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field
More informationCroma Enterprise Cromtech India
UV 1601 - Split Beam & Dual (equivalent to Double beam Spectro Photometer ) Wide wavelength range, satisfying requirements of various fields. The split-beam ratio monitoring system provides accurate measurements
More informationProduct data sheet Palas Fidas 200 E
Product data sheet Palas Fidas 200 E Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Long-term studies Emission source classification Distribution
More informationFlow-Cell FC200S+ OCCHIO. The best solution for measuring suspensions,emulsions and foams
Y o u n e e d p r e c i s i o n, y o u w a n t m o r p h o l o g y OCCHIO Flow-Cell FC200S+ The best solution for measuring suspensions,emulsions and foams OCCHIO C C H I O Pharma F l o w - C e l l FC200S+
More informationAuto Ref / Kerato / Tono / Pachymeter TONOREFTM III
Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III The space saving TONOREF TM III is a comfortable and efficient upgrade to your practice High Measurement Accuracy Refraction Large Pupil Zone Imaging
More informationUSB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system
Visible range spectrophotometers V-1100 and VR-2000 V-1100 MODEL WITH MANUAL WAVELENGTH SETTINGS AND AUTOMATIC BLANK. VR-2000 MODEL WITH AUTOMATIC WAVELENGTH SETTINGS AND BLANK. V-1100 Part no. 4120025
More informationJoliot Type Spectrometer. photosynthesis system JTS-10. A LED pump-probe spectrometer
photosynthesis system Joliot Type Spectrometer JTS-10 A LED pump-probe spectrometer General Specifications Standard applications Single setup for fluorescence and absorbance changes NPQ Integrated array
More informationFaster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)
Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P) Auto Lensmeters LM-1200 / 1000(P) Advanced & Dynamic Technologies Provide for Faster, Easier and More Accurate Measurement Faster & Easier
More informationUV / VIS Spectrophotometer
UV / VIS Spectrophotometer Single Beam Double Beam NANO EMCLAB Instruments GmbH EMCLAB Instruments GmbH Kulturstrasse 55 47055 Duisburg Germany Fon: +49 203 3064042 Fax: +49 203 41504809 E-mail: info@emc-lab.de
More informationThe Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.
The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, 31-342 Kraków, Poland. www.ifj.edu.pl/reports/2003.html Kraków, grudzień 2003 Report No 1931/PH
More informationNon-Mydriatic Auto Fundus Camera AFC-330
Non-Mydriatic Auto Fundus Camera AFC-330 The Smart Fundus Camera What is the smart fundus camera? It is a camera that is sophisticated, technologically advanced, and user-friendly. The AFC-330 speaks for
More informationOptical Spectrum Analyzer AQ6331. A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
Optical Spectrum Analyzer AQ6331 A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Compact, lightweight and high-spec! The AQ6331 is a new portable
More informationSimplicity. Reliability. Performance. ProdigyPlus
Simplicity Reliability Performance ProdigyPlus ProdigyPlus High Dispersion ICP Spectrometer All the capability you ll ever need in an ICP. From basic applications to the most complex research task, Prodigy
More informationHandheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef
Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef A valued assistant that is always at hand Wouldn t you want to be able to take an accurate measurement anytime and anywhere? NIDEK
More informationStepping Motor Station
Stepping Motor Station PV-7300 System A single system can measure all seven of the characteristics important in a stepping motor, namely the -T characteristic, holding torque, detent torque, pull-in torque,
More informationOpto Devices Product Information LED
Opto Devices Product Information LED 01 USHIO s Goal USHIO s Goal 1 ONE STOP SOLUTION with USHIO s LED and LD Optimization: USHIO will propose the best device to your application from both LED and LD.
More informationConfocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series
Confocal NEXIV VMZ-K Series CNC Video Measuring System CONFOCAL NEXIV VMZ-K Series 3D FOV Measurements Generated with Confocal Images The Confocal NEXIV VMZ-K series, a ground-breaking multifunctional
More informationDurst HL 2506 AF. Durst HL 2506 AF
Durst HL 2506 AF Durst HL 3506 AF Professional horizontal enlarger for colour and BW-enlargements from film formats up to 25 x 25 cm (10 x 10 in.) with computer driven Permanent Closed Loop light monitoring
More informationAgilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth
Agilent 8703B Lightwave Component Analyzer Technical Specifications 50 MHz to 20.05 GHz modulation bandwidth 2 The 8703B lightwave component analyzer is a unique, general-purpose instrument for testing
More informationConfocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series
Confocal NEXIV VMZ-K Series CNC Video Measuring System CONFOCAL NEXIV VMZ-K Series The VMZ-K series enables microscopic height measurements using various objective lenses, with two models to choose from,
More informationF210 Vision Sensor Flow Menus and Macro Capability
F210 Vision Sensor Flow Menus and Macro Capability Reduce the overhead involved in system planning and introduction. The Three Features of Flow Menus and Macros The Flow Menus and Macros of the F500-UM3FE/UM3ME
More informationZEPHYR LDA. Laser Diffraction Alternative. m 3000 m. Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0)
Imaging particle analyzers 200 nm 5 cm ZEPHYR LDA Laser Diffraction Alternative m 3000 m Occhio SA, 4 rue des chasseurs ardennais BE4031 Angleur (Belgium) Tel:+32 (0) 42 43 00 14 Imaging analyzers from
More informationSpectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD.
Spectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD. High resolution satisfying European Pharmacopoeia (spectral bandpass: 1.5 nm). Trace-amount measurement
More informationThe HORIBA LA-960. Simple, Powerful, Reliable Particle Size Measurement. Ian Treviranus
The HORIBA LA-960 Simple, Powerful, Reliable Particle Size Measurement Ian Treviranus ian.treviranus@horiba.com www.horiba.com/particle LA-960 Laser Particle Size Analyzer a What we ll talk about Ease
More informationHigh-Accuracy Surface Scanning Method
Surface Scanning Laser Confocal Displacement Meter LT-9000 Series First in the world High-Accuracy Surface Scanning Method High resolution of 0.3 µm The high-accuracy, surface scanning method allows measurements
More informationSatellite Tracer LT-1200 / 980
Satellite Tracer LT-1200 / 980 Satellite Tracer LT-1200 / 980 Confidently performs around all curves The LT-1200 and LT-980 tracers incorporate an advanced state-of-the-art and newly engineered tracing
More informationFor Isotropic Measurement of Magnetic and Electric Fields
Field Analyzers EFA-300 For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field Exposure compared to Major Standards and Guidance (selectable) Shaped Time Domain (STD) an innovative
More informationVeraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation
Diagnostic and Imaging Equipment Treatment Units Handpieces and Instruments Endodontic Systems Laser Equipment Laboratory Devices Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced
More informationVisual Inspection by Digital Solution.
Visual Inspection by Digital Solution. R Digital LUPE * Images are exemplary only. Making Visual Inspection more Precise and Efficient The level of quality control can be greatly improved by using monitor
More informationComplete support to all your needs
CNC Video Measuring Systems Ryf AG Bettlachstrasse 2 2540 Grenchen tel 032 654 21 00 fax 032 654 21 09 www.ryfag.ch Complete support to all your needs The perfect answer to all your measurement needs The
More informationWafer Loaders for IC Inspection Microscopes NWL200 Series. Wafer Loaders for IC Inspection Microscopes
Wafer Loaders for IC Inspection Microscopes NWL200 Wafer Loaders for IC Inspection Microscopes Wafer Loaders for IC Inspection Microscopes I Nikon s original technology ensures safe, reliable loading of
More informationDeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)
DeltaMyc Fluorescence Lifetime Mapping Microscope Affordable Fluorescence Lifetime Imaging Microscopy (FLIM) DeltaMyc Affordable Fluorescence Imaging Lifetime Microscopy (FLIM) At last, an affordable yet
More informationPark NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.
Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis www.parkafm.com Park NX-Hivac High vacuum scanning for failure analysis applications 4 x 07 / Cm3 Current (µa)
More informationForward-looking technologies. Seamlessly integrated. cad integration
Forward-looking technologies. Seamlessly integrated. cad integration hypermill The most comprehensive range of CAM strategies under a single interface hypermill is certified as a Gold Product by SolidWorks.
More informationMEASUREMENT APPLICATION GUIDE OUTER/INNER
MEASUREMENT APPLICATION GUIDE OUTER/INNER DIAMETER Measurement I N D E X y Selection Guide P.2 y Measurement Principle P.3 y P.4 y X and Y Axes Synchronous Outer Diameter Measurement P.5 y of a Large Diameter
More informationIntroduction of New Products
Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can
More informationVisible & UV/Vis Spectrophotometers
Visible & UV/Vis Spectrophotometers Accurate Precise Affordable S20 Series UV/Vis Spectrophotometers The Unico S20 Series Spectrophotometers are simple, flexible, easytouse and maximize value while providing
More informationHitachi Double Beam Spectrophotometer
Hitachi Double Beam Spectrophotometer Spectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD. High resolution satisfying European Pharmacopoeia (spectral
More informationOptical Biometer AL-Scan
Optical Biometer AL-Scan State 10 Seconds to Measure 6 Values Rapid measurements are essential for clinical efficiency and patient comfort. NIDEK s solution is the state of the art optical biometer - the
More informationT92+ UV-VIS SPECTROPHOTOMETER
T92+ UV-VIS SPECTROPHOTOMETER The T92+ is a high performance double beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous variable slit. The instrument is fitted
More informationTechnical Benefits of the
innovation in microvascular assessment Technical Benefits of the Moor Instruments moorflpi-2 moorflpi-2 More Info: Measurement Principle laser speckle contrast analysis Measurement 85nm Laser Wavelength
More informationMAGNETOSCAN MAGNETIC MEASURING SCANNER
LABORATORIO ELETTROFISICO MAGNETOSCAN MAGNETIC MEASURING SCANNER Fully automated ease with micrometrical accuracy A magnetic measuring scanner, the Magnetoscan is designed to measure the superficial magnetic
More informationHP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm
HP 8509B Lightwave Polarization Analyzer Product Overview polarization measurements of signal and components 1200 nm to 1600 nm 2 The HP 8509B Lightwave Polarization Analyzer The HP 8509B lightwave polarization
More informationAuto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1
Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 The Superior Auto and Auto What is the superior auto ref / The ARK-1 / AR-1 series speak for themselves, and auto refractometer generating greater
More informationAuto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1
Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 The Superior Auto and Auto What is the superior auto ref / The ARK-1 / AR-1 series speak for themselves, and auto refractometer generating greater
More informationOptical Coherence Tomography Retina Scan Duo
Optical Coherence Tomography Retina Scan Duo High Definition OCT & Fundus Imaging in One Compact System The Retina Scan Duo is a combined OCT and fundus camera system that is a user friendly and versatile
More informationAD-4826 AD G/200G/500G. For high-speed, highly accurate continuous feeding of powder and dry solids. Model predictive feeder controller
Patent pending For high-speed, highly accurate continuous feeding of powder and dry solids AD-4826 Model predictive feeder controller AD-4826-30G/200G/500G Vibratory feeder http://www.aandd.jp Model predictive
More informationSpectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam
Spectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam Software Specifications Model UVD-3500 Spectro UV-VIS Double Beam UVD 3500 Research Spectrophotometer is a superior instrument for
More informationSEIMITU WAVE AR1260. Allegro. Mobility LLC
SEIMITU WAVE Allegro AR1260 Mobility LLC 3-5-6, Zenpukuji, Suginami-ku, Tokyo 167-0041 Japan Tel : 81-03-6454-7730 Fax : 81-03-6454-7292 E-Mail : info@mobilityjapabcom URL : http://wwwmobilityjapancom/
More informationHSV-2000 High Speed Vibrometer
HSV-2000 High Speed Vibrometer Measurement of Vibration Velocity and Displacement at High Speeds Non-contact Single point or differential Velocities up to ± 30 m/s High Speed Capability The HSV-2000 High
More informationOCULUS Keratograph 4. Topographer. We focus on progress
OCULUS Keratograph 4 Topographer We focus on progress Ophthalmologist Versatile and precise For me the Keratograph 4 is an indispensable device for diagnosis and surgical planning. Its automatic measurement
More informationPIRest Actuators ACTIVE SHIMS WITH LONG-TERM STABILITY AND NANOMETER RESOLUTION
PIRest Actuators ACTIVE SHIMS WITH LONG-TERM STABILITY AND NANOMETER RESOLUTION PIRest Technology Using PIRest active shims COMPLETELY NEW PIEZO TECHNOLOGY FOR ACTIVE ADJUSTMENT OF CONSISTENTLY STABLE
More informationCLV 480 Bar Code Scanner For near and far Dynamic focus control Advanced line
Product Information CLV 480 Bar Code Scanner For near and far Dynamic focus control Advanced line A large range of applications One device The CLV 480 enables omni-directional reading of bar codes for
More informationTechnical Explanation for Displacement Sensors and Measurement Sensors
Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting
More informationSintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:
Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore 658079 Tel: +65 63167112 Fax: +65 63167113 Full Laser Parts in Nd:YAG Lasers For lamp-pumped Nd:YAG lasers and diode-pumped
More informationSpectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.
Spectroradiometer CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. 15 World's top level capability to detect extremely low
More informationSolutions for Lithium Ion Battery Manufacturing
Solutions for Lithium Ion Battery Manufacturing NDC Advantage Series NDC ADVANTAGE - LITHIUM ION BATTERY Measurement and Control Solutions Achieve a new level of quality and performance with NDC Technologies
More informationDROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES
DROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES PRECISION AND PERFECTION QUITE AUTOMATICALLY Options for complete software-controlled surface analysis
More informationBack-illuminated scientific CMOS camera. Datasheet
Back-illuminated scientific CMOS camera Datasheet Breakthrough Technology KURO DATASHEET Highlights The KURO from Princeton Instruments is the world s first scientific CMOS (scmos) camera system to implement
More informationINSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01
INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01 EL-221, MIDC Electronic Zone, Mhape, Navi Mumbai-400710. Tel: 022- 61393000 CHAPTER 1 INTRODUCTION Contech CDO-01 measures Dissolved Oxygen and temperature
More informationCNC Video Measuring System NEXIV VMZ-K series. CNC Video Measuring System. Confocal Model
CNC Video Measuring System NEXIV VMZ-K series CNC Video Measuring System Confocal Model D FOV Measurements Generated with s A ground-breaking multifunctional video measuring system developed on the strength
More informationSpecifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism
SpectraPro Series Monochromators and Spectrographs The PI/Acton SpectraPro Series imaging spectrographs and monochromators represent the latest advance in the industry-standard SpectraPro family. The SpectraPro
More informationMorphologi. Advanced image analysis for high sensitivity particle characterization. Particle size. Particle shape
Particle size Particle shape Morphologi detailed specification sheets from www.malvern.co.uk Introducing a new concept in image analysis The Morphologi high sensitivity particle analyzer is more than just
More informationCONTENTS Product Accessory Software V /02 V-5100/UV /04 UV-5100B 05/06
CONTENTS Product V-5000 01/02 V-5100/UV-5100 03/04 UV-5100B 05/06 V-5600/UV-5600/V-5800/UV-5800 07/08 UV-6000 09/10 UV-6100/6100A/6100S 11/12 UV-9000/UV-9000A/9000S 13/14 B-500 15 TOC-2000/TOC-3000 16/17
More informationVMZ-K3040 CONFOCAL. Confocal Imaging & Metrology. CNC Video Measuring System. Specifications. Dimensional Diagram
Specifications Types Type - S Objectives Magnification W.D. Confocal Imaging & Metrology Type - H 3x 7.5x 15x 30x 24mm 5mm 20mm 5mm Confocal optics (Area height measurement) Maximum scan height Field of
More informationEdging Station LE-700
Edging Station LE-700 Simple, built-in intelligent blocker Simple, accurate blocking The built-in intelligent manual blocker enables the operator to achieve accurate blocking with simple operation. Precise
More informationVeraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.
Veraview IC5 HD High definition, digital imaging excellence Thinking ahead. Focused on life. 2 Thinking ahead. Focused on life. 3 4 IC5 HD Ultra-fast Panoramic Images with Outstanding Resolution For dental
More informationQuick and simple installation and no maintenance needed. 3 Times More affordable Than a normal SEM. Obtaining results in less than 4 minutes
INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM series of SEM. In short space of time, our device
More informationUltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related
UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to
More informationImaging Photometer and Colorimeter
W E B R I N G Q U A L I T Y T O L I G H T. /XPL&DP Imaging Photometer and Colorimeter Two models available (photometer and colorimetry camera) 1280 x 1000 pixels resolution Measuring range 0.02 to 200,000
More informationDIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000
DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA Truly Magnificent Digital Imaging Non-Mydriatic Fundus Camera Digital Imaging for Optimal Screening:Diabetes, Glaucoma Macular Degeneration, and Other Retinal
More informationContent Spectrophotometers
Spectroph Content Spectrophotometers Selection table Spectrophotometers Page 163 PRIM Page 164 UviLine Page 166 162 Selection table Spectrophotometers PRIM Light/ PRIM Advanced UviLine 9100/ UviLine 9400
More informationPhotoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.
More information