Regency Bellavista B41XT-1 Gas Fireplace

Size: px
Start display at page:

Download "Regency Bellavista B41XT-1 Gas Fireplace"

Transcription

1 Regency ellavista 1XT-1 Gas Fireplace Specifications: Model 1XT-NG 1XT-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (.7 kpa) 1. W.C. (. kpa) 11 W.C. (.7 kpa) 1 W.C. (.9 kpa). W.C. (1. kpa) Orifi ce Size #3 DMS #9 DMS Minimum Input ltitude -5 ft. (-137m) Maximum Input ltitude -5 ft. (-137m) 3, TU/h (.79 kw),5 TU/h (1.5 kw) 9,5 TU/h (.5kW) 37,5 TU/h (1.99 kw) Vent Sizing 5 Inner / Outer 5 Inner / Outer pproved Venting Systems Flex Vent Systems: FPI strocap Flex Vent Rigid Pipe Vent Systems: Simpson Direct Vent Pro Selkirk Direct-Temp Metal-Fab Sure Seal ICC Excel Direct Framing Dimensions: Framing Description 1XT Dimensions M Framing Width 7-1/"(1mm) N Framing Height 9-1/" (157mm) O (Rear Vent) Framing Depth - Rear Vent 3-1/" (591mm) O (Top Vent) Framing Depth - Top Vent -5/" (575mm) P Corner Facing Wall Width -1/" (153mm) Q Corner Facing Wall Width 5-3/1" (13mm) R (Rear Vent) Framed Chase Ceiling - Rear 9-1/" (157mm) R (Top Vent) Framed Chase Ceiling - Top 5-1/" (13mm) S (Rear Vent) Vent Centerline Height - Rear -1/" (7mm) S (Top Vent) Vent Centerline Height - Top 7-1/" (17mm) Rigid / Flex T Gas Connection Height 1-1/" (3mm) U Gas Connection Inset 5" (17mm) V Gas Connection Width 3-1/" (mm) W Non-Combustible Top Height 13-1/" (33mm) ** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth. R Unit Dimensions: -11/1 (11mm) Non-Combustible N Drywall, Wood (or other facing) W Non-Combustible Non-Combustible Facing 3-3/1 (97mm) M O 11" (79mm) dia. Hole through wall Vent. 19-7/1 (9mm) -5/1 (57mm) P Rear Vent S Top Vent S T 1 (5mm) 1-11/1 (159mm) (1mm) 35 (9mm) 3-11/1 (93mm) 9-3/1 (19mm) 3-1/ (591mm) 13-3/1 (335mm) -1/ (7mm) 3-3/ (9mm) 3-1/ (97mm) (17mm) 5-1/" Q -3/" (13mm) Material 1-3/" (1mm) 3-3/" (933mm) U V Opening for gas connection Non-Combustible Requirements: Min. 13-1/" (33mm) 7-1/" (1mm) Framing Min. 3-1/ (9mm) Min. 3-1/ (9mm)

2 Regency ellavista 1XT -1 Gas Fireplace Clearance Requirements: E D F C lcove F Minimum Vent Clearances to Combustibles Horizontal Top 3" (7mm) Horizontal Side " (51mm) Horizontal ottom " (51mm) Vertical Vent " (51mm) E Clearance: Dimension Measured From: : Mantel Height (min.) 15" (31mm) Top of Fireplace Opening : Sidewall 9" (9mm) Side of Fireplace Opening C: Ceiling 33-3/" (933mm) Top of Fireplace Opening D: Mantel Depth (max.) 1" (3mm) 3-1/" (19mm) from Top of Fireplace Opening E: lcove Width " (15mm) Wall to Wall (Minimum) F: lcove Depth 3" (9mm) Front to ack Wall (Maximum) Notes: " No Hearth Required NOTE: 1" deep non-combustible hearth pad is recommended for hardwood fl ooring and carpet. Combustible Mantels: Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Mantel Clearances 1XT From Top of Fireplace Opening C D 35-1/" (95mm) 3-1/" (591mm) 19-1/" (95mm) 15" (31mm) Note: Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour. 1 1 Mantel Leg Clearances: 1 7 Combustible Top View 1-1/ Side Wall (Measured from side of Fireplace Opening) Mantel leg 1-1/" Mantel leg 7 llowable mantel leg projection. 3" Inches C To Floor D Top of Fireplace Opening 1" 13-1/ Standoff Side View

3 Regency ellavista 1XT -1 Gas Fireplace Venting rrangements for Horizontal Terminations: The diagrams show all allowable combinations of vent runs with 5" x " venting using the Regency direct vent system or rigid vent system. vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes. For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum continuous vent length of 1ft (3.m). Note: Must use optional rigid pipe adaptor (Part # 77-99) when using Rigid Pipe vent systems. Maintain clearance to combustibles. Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. 1 1 Max. 3 (.9m) Rigid or Flex 7-1/" (1.m) Max. 3"(.9m) - 1/"(.7m) Vent Restrictor - Set 1 Factory Setting - No Restrictor Required IMPORTNT Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications. Horizontal Terminations - Rigid Pipe 5 x : Top Vent - No Vertical Rise When venting with a 9 elbow directly off the unit Flex vent or approved Rigid Vent System Max. 3 ft. horizontal run Rear Vent w/ Horizontal Termination Max. 3ft. horizontal run Horizontal Termination Cap Rigid Pipe daptor Horizontal Termination Cap o 9 Elbow Rigid Pipe daptor IMPORTNT Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications.

4 Regency ellavista Horizontal Terminations: STROCP XL & RIGID RER VENT KIT FOR CORNER INSTLLTIONS Designed for a minimum vent confi guration when using a rear vent application with a horizontal termination in a corner installation. Kit# 9-1 Includes: 1 strocap XL 9-3/P 1 Rigid Pipe daptor DV-WT Placement of the Unit into the Corner ack Top Corner of Unit to Wall 3" Inside Corner out along the Wall -1/" cross the Face of the Unit, Wall to Wall 5-3/1" - Clearance to Outside Corner 13" - Clearance to Inside Corner 5-1/" 1 " Galvanized Rigid Pipe 5DV- 1-1/" Galvanized Pipe Extension 5DV- 1 5º Galvanized Elbow 5DV-E5 1 9ml MillPac 9-1 Standoff (Optional) 3-1/ strocap XL 5-3/1 5 elbow Rigid Pipe daptor IMPORTNT Must use Rear Venting Deflector packaged with unit in rear vent horizontal termination applications. asic Horizontal & Vertical Terminations: Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish. Vertical Terminal Storm Collar The minimum components required for a basic Horizontal Termination are: 1 strocap XL Termination Cap 1 9 o Elbow 1 Rigid Pipe daptor 1 1 Length of rigid pipe to suit wall thickness The minimum components required for a basic Vertical Termination are: 1 Vertical Termination Cap 1 Rigid Pipe daptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl, furring strips may be used, instead of a vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips. Flashing Ceiling Firestop Pipe Length o 9 Elbow Rigid Pipe daptor (77-99) strocap XL Termination Cap (Part #9-3/P) (Mandatory in all Horizontal Terminations) Vent Guard - if required* (Part #9-5/P) If a Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add inches.

5 Regency ellavista VENTING RRNGEMENTS FOR HORIZONTL TERMINTIONS FOR VERTICL TERMINTIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 9 o (two 5 o elbows equal one 9 o elbow). Maintain clearances to combustibles as listed in "Clearances" section Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. wall thimble is mandatory for all horizontal terminations due to high temperatures The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 9 o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 5 o elbows equal to one 9 o elbow. Maximum of four 5 o elbows allowed. Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles as listed in the "Clearances" section. Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 3-1/" opening, -1/"opening and to 1-1/" opening Restrictor 1-1/ Open Set Restrictor -1/ Open Set Restrictor 3-1/ Open Set Maximum: 35.5 ft. (1. m) Restrictor 1-1/ Open Set 3 7-1/" (17mm) Minimum Height Requirement 1 Restrictor -1/ Open Set Restrictor 3-1/ Open Set 1 Maximum 1 Centerline to Centerline Min. 7-1/ (1.m) Minimum (.m) Maximum Centerline to Centerline

Contemporary Collection

Contemporary Collection HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold

More information

Contemporary Collection

Contemporary Collection HZ4STE Gas Fireplace Model HZ4STE - NG1 HZ4STE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.49 kpa)

More information

U1500E Gas Fireplace

U1500E Gas Fireplace Model U1500E-NG U1500E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.5 W.C. (0.87 kpa) 10 W.C. (2.48 kpa) Manifold Pressure -

More information

HZO60 Outdoor Decorative Fireplace

HZO60 Outdoor Decorative Fireplace Specifications: HZO60 Outdoor Decorative Fireplace Model HZO60-NG HZO60-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Minimum Supply Pressure Manifold Pressure - High 14 W.C. (3.49 kpa)

More information

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. E33 GAS INSERT ZERO CLEARANCE KIT Owner's & Installation KIT # 340-900 Manual PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance

More information

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING HEARTH PRODUCTS KITS AND ACCESSORIES 750052M Rev. C 05/2014 VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING INSTALLATION INSTRUCTIONS FOR SECURE FLEX VERTICAL TERMINATION KITS (CATALOG NO. 56L74

More information

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE C Series Cool Surface System FRONT VENT [50-3463] INSTRUCTION MANUAL 4001609 This Cool Surface System has been tested for compliance to Standards: ANSI

More information

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney. INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE

More information

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10. TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 36 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508090 4020405 $10.00 P AGE 2 TABLE OF CONTENTS

More information

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

TYPE B GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney. TYPE "B" GAS VENT SD (sizes 3", 4", 5", 6", 7") INSTALLATION INSTRUCTIONS Type "B" Gas Vents are strictly for interior or enclosed exterior use or exterior use above a roof line. Read vent and appliance

More information

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10. TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 44 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508093 4020405 $10.00 P AGE 2 TABLE OF CONTENTS

More information

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent. LockTab Feature for Type Gas Vent Our non-positional lock system on the Selkirk Gas Vent is the best lock system on the market today. The incorporation of the LockTab feature simply improves our lock system

More information

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame INSTALLATION INSTRUCTIONS AND OPERATIONS Firebox Model SWK24 Frame Models SWKL24-LAGUNA (Figure 1) SWKS24-SANDIA SWKH24-HOPI

More information

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL 18 24 30 Kiva Fireplace WOOD BURNING INSTALLATION MANUAL Frame Models: Orno Santa Fe Navajo Zuni Keep these instructions for future use. C This fireplace is to be installed ONLY by a construction industry

More information

ZERO CLEARANCE MANUAL

ZERO CLEARANCE MANUAL 1 NEO 1.6 & NEO 2.5 ZERO CLEARANCE MANUAL Distributed by Pivot Stove & Heating Co 1300 474 686 pivotstove.com.au 1 CONTENTS 1 x base plate 2 x side panels inner 2 x side panels outer 2 x top plates 2 x

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT

More information

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

ECOVENT USA CHIMNEY MODEL EV-SHT 5-8 DIAMETER INSTALLATION INSTRUCTIONS ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS

More information

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

DURATECH CHIMNEY 5-8 DIAMETER INSTALLATION INSTRUCTIONS DURATECH 5"-8" DIAMETER INSTALLATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPOR- TANCE

More information

60/100 Concentric Flue System Parts

60/100 Concentric Flue System Parts 60/00 Concentric Flue System Parts MG88(MG85 m extended option) Std Concentric Flue 60/00 (Avanta Plus). Low profile bend (Avanta Plus). Telescopic terminal. Wall plates - ( x white) MG80 Vertical Terminal

More information

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# ) Compatibility ProBuilder Linear CoolSmart TV ProBuilder Series Linear Fireplaces (42PB, 54PB & 72PB) Packing List Convection Manifold (with grill and mounting brackets pre-attached) 5 Diameter Aluminum

More information

Accentra 52i Pellet Insert Zero Clearance Cabinet Part #

Accentra 52i Pellet Insert Zero Clearance Cabinet Part # Accentra 52i Pellet Insert Zero Clearance Cabinet Accentra 52i Pellet Insert ZC Cabinet Accentra 52i Pellet Insert Mounting Frame Accentra 52i Pellet Insert www.harmanstoves.com R:\Todd\Instruction Sheets_3-89-574323_RevC

More information

Kiva Fireplace GAS BURNING INSTALLATION MANUAL WITH DOUBLE WALL AIR COOLED CHIMNEY

Kiva Fireplace GAS BURNING INSTALLATION MANUAL WITH DOUBLE WALL AIR COOLED CHIMNEY 18 24 30 Kiva Fireplace GAS BURNING INSTALLATION MANUAL WITH DOUBLE WALL AIR COOLED CHIMNEY Frame Models: Orno Santa Fe Navajo Zuni Keep these instructions for future use. This fireplace is to be installed

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR

More information

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL.   TRADITIONAL GAS FIREPLACES www.regency-fire.com TRADITIONAL GAS FIREPLACES TRADITIONAL GAS FIREPLACES WHY CHOOSE REGENCY? BEAUTIFUL HOME HEATING SOLUTIONS Regency Fireplace Products was founded over 35 years ago with a mission to

More information

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL.   TRADITIONAL GAS FIREPLACES www.regency-fire.com TRADITIONAL GAS FIREPLACES TRADITIONAL GAS FIREPLACES WHY CHOOSE REGENCY? BEAUTIFUL HOME HEATING SOLUTIONS Regency Fireplace Products was founded over 35 years ago with a mission to

More information

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL.  TRADITIONAL GAS FIREPLACES www.regency-fire.com TRADITIONAL GAS FIREPLACES TRADITIONAL GAS FIREPLACES WHY CHOOSE REGENCY? BEAUTIFUL HOME HEATING SOLUTIONS Regency Fireplace Products was founded over 35 years ago with a mission to

More information

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS ROOM SEALED NON-CONDENSING COMBINATION/SYSTEM BOILERS AND WATER HEATERS 24i 47 311 37/38 9/14 CBi 41 311 50/51 28i 47 311 54 14/19 CBi 41 311 52/53

More information

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

GE Monogram. Installation. Instructions. 36 Vent Hood. Model ZV750. Call anywhere in the US and Canada - at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:

More information

Chaska 34, Chaska 335s, Chaska 29, Chaska 25

Chaska 34, Chaska 335s, Chaska 29, Chaska 25 quality fireplaces for life. Kozy Heat Fireplaces Chaska 34, Chaska 335s, Chaska 29, Chaska 25 Chaska 34-L shown with a Rectangle screen front with an Antique Copper overlay, log set and ember light kit

More information

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the Model 80 manual from the Stove Manuals section of our

More information

contemporary gas fireplaces

contemporary gas fireplaces contemporary gas fireplaces why choose Regency? Fire Transformed to Art My vision was to elevate the role of a fireplace beyond the heating function to a highly stylized art form for today s trend toward

More information

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR CANADA TEMP/ GUARD 650 C TEMP/GUARD CHIMNEY SIZES 6-7 - 8 300ºC TEMP/GUARD CHIMNEY Listing No. MH 8251 Tested to UL103 HT / ULC-S629 / ULC-S604 / ULC-609 SIZES

More information

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25 QUALITY FIREPLACES FOR LIFE. KOZY HEAT FIREPLACES CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25 Chaska 34 Log shown with a Rectangle screen front with an Antique Copper overlay, log set, custom 4-sided

More information

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF

More information

Crave Series. Direct Vent Gas Fireplaces

Crave Series. Direct Vent Gas Fireplaces Crave Series Direct Vent Gas Fireplaces Crave 72 modern luxury in 36, 48, 60 and 72 inches The Crave provides modern luxury at an affordable price. Multiple upgrade options let you accent your style and

More information

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# ) Compatibility ProBuilder Series CoolSmart TV ProBuilder Series Linear Fireplaces (42PB, 54PB & 72PB) Packing List Convection Manifold (with grill and mounting brackets pre-attached) 5 Diameter Aluminum

More information

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25 QUALITY FIREPLACES FOR LIFE. KOZY HEAT FIREPLACES CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25 Chaska 34 Log shown with a Rectangle screen front with an Antique Copper overlay, log set, custom 4-sided

More information

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications.

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications. CTLOG Type Gas Vent GV-25 Round and oval gas vent pipe and fittings for residential, commercial and industrial applications. FETURES Snap together non-positional lock system Die formed ends Venting gas

More information

SLP-LPC. Installation & Operating Instructions. SLP-LPC Preparation

SLP-LPC. Installation & Operating Instructions. SLP-LPC Preparation SLP-LPC Installation & Operating Instructions Leave this manual with party responsible for use and operation. CAUTION! Do not install damaged components. The Low Profile Cap (LPC) is NOT approved for all

More information

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COM- BUSTIBLE MATERIALS. IT IS OF THE UTMOST

More information

Installation Instructions Window Opening Control Device. Single-Hung & Sliding Windows with No Vent Latches

Installation Instructions Window Opening Control Device. Single-Hung & Sliding Windows with No Vent Latches Single-Hung & Sliding Windows with No Vent Latches These s (WOCDs) work with single-hung windows and sliding windows with one operational and one stationary sash in the confi gurations of either XO or

More information

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UPMOST

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions This symbol on the product means the product is listed by Underwriters Laboratories, Inc. AMERI-VENT MODEL 10 FB FACTORY-BUILT CHIMNEY These are the three ways to

More information

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TABLE OF CONTENTS This installation guide provides detailed step-by-step instructions for do-it-yourself projects. We invite you to read it carefully and

More information

Regency Horizon HZ30E Contemporary Direct Vent Gas Fireplace

Regency Horizon HZ30E Contemporary Direct Vent Gas Fireplace Regency Horizon HZ30 ontemporary irect Vent as ireplace 2014 PI ireplace Products International Ltd. Regency is a registered trademark of PI. NW NW Standard eatures ;Natural;gas;or;propane Safety;screen

More information

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

FACTORY BUILT INSULATED CHIMNEY

FACTORY BUILT INSULATED CHIMNEY & INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (CANADA & UNITED STATES) FACTORY BUILT INSULATED CHIMNEY LISTED Tested to UL03 Type HT LISTED Tested to ULC-S604 ULC-S60 A MAJOR CAUSE OF CHIMNEY RELATED

More information

Monogram 36" Built-In Bottom-freezer Refrigerator

Monogram 36 Built-In Bottom-freezer Refrigerator SETION 1 FLUSH INSET INSTLLTION SETION 2 STNR INSTLLTION 1/4" FRME PNELS 3/4" OVERLY PNELS OVERLL IMENSIONS FTER PNEL INSTLL FLUSH INSET INSTLLTION 38" (96.5) 26" (66.0) 20 5/8" (52.4) 11 1/2" (29.2) *

More information

MONOGRAM 36" BUILT-IN ALL-REFRIGERATOR

MONOGRAM 36 BUILT-IN ALL-REFRIGERATOR SETION 1 STNR INSTLLTION 1/4" FRME PNELS 3/4" OVERLY PNELS SETION 2 INSTLLTION OVERLL IMENSIONS STNR INSTLLTION 25 1/8" (63.8) 36" (91.5) 23 7/8" (60.7) 1 7/8" (4.8) *84" (213.4) *83 1/2" (212.1) 69 5/8"

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

Fireside Retreat. Craftsman-Style BEFORE

Fireside Retreat. Craftsman-Style BEFORE Craftsman-Style Fireside Retreat BEFORE { We transformed this ordinary living room into the warm, inviting retreat shown above one project at a time. I t s pretty obvious, right? A living room is meant

More information

Shapes Siding. Perfection Shingles. Chalk Line

Shapes Siding. Perfection Shingles. Chalk Line Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter

More information

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF

More information

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F.

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F. Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

MONOGRAM 36" BUILT-IN ALL-REFRIGERATOR

MONOGRAM 36 BUILT-IN ALL-REFRIGERATOR MONOGRM 36" UILT-IN LL-REFRIGERTOR SETION 1 STNR INSTLLTION 1/4" FRME PNELS 3/4" OVERLY PNELS SETION 2 FLUSH INSET INSTLLTION MONOGRM 36" UILT-IN LL-REFRIGERTOR OVERLL IMENSIONS STNR INSTLLTION 25 1/8"

More information

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech Installation Instructions All-Fuel Chimney System 10 to 24 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS

More information

MM700R Recess Box Kit Addendum

MM700R Recess Box Kit Addendum TM MM700R Recess Box Kit Addendum IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Please read this entire manual before you begin. Do not unpack any contents until you verify additional requirement

More information

Rythmik Audio. DS1500v - 3 cu ft vented enclosure. Articulate bass for the discerning audiophile. Feet Dimensions: 1.5 x 1.5 x 2.5

Rythmik Audio. DS1500v - 3 cu ft vented enclosure. Articulate bass for the discerning audiophile. Feet Dimensions: 1.5 x 1.5 x 2.5 DS1500v - 3 cu ft vented enclosure Driver: DS1500 15 (Driver cutout: 14 1/16") Enclosure dimensions: 18 wide x 24 deep x 25 high Enclosure material: ¾ MDF (Medium Density Fibreboard) Feet Dimensions: 1.5

More information

HowtoPlans..org. 12'x20' Garden Shed Plan

HowtoPlans..org. 12'x20' Garden Shed Plan HowtoPlans.org 12'x20' Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard or

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual [USA Fireplace Models [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE MODELS: STAND ALONE 7565 CURVED TUNNEL DOUBLE

More information

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie  . Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS Web. acrylicdesign.ie Email. sales@acrylicdesign.ie Acrylic Design 2004-2015 Mobile Cable System Components Single panel clamp Stand Off for

More information

PRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5" to 8" Diameter

PRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5 to 8 Diameter PRODUT TLOGUE RIGID STINLESS STEEL HIMNEY LINER 5" to 8" Diameter Listed To: UL-S635, UL-S640 and UL 1777 Get the Selkirk dvantage... The tradition continues...selkirk is the original innovator of prefabricated

More information

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to

More information

INSERTS GAS FIREPLACE. GAS FIREPLACE INSERTS

INSERTS GAS FIREPLACE.   GAS FIREPLACE INSERTS www.regency-fire.com GAS FIREPLACE INSERTS GAS FIREPLACE INSERTS why choose Regency? Beautiful Home Heating Solutions Regency Fireplace Products was founded over 35 years ago with a mission to produce

More information

HRI4E REGENCY HORIZON MEDIUM GAS INSERT STANDARD FEATURES. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black Crystals.

HRI4E REGENCY HORIZON MEDIUM GAS INSERT STANDARD FEATURES. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black Crystals. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black rystals. REGENY HORIZON MEDIUM GAS INSERT HRI4E HRI4E shown with regular backing plate, vignette faceplate in Black, raftsman

More information

LRI6E LIBERTY RADIANT LARGE GAS INSERT RADIANT CONVECTIVE HEAT

LRI6E LIBERTY RADIANT LARGE GAS INSERT RADIANT CONVECTIVE HEAT LRI6E shown with Regular Backing Plate, Vignette Faceplate in Black, raftsman inlay in Tuscan Sunset and Rustic Brown Brick Panels. LIBERTY RADIANT LARGE GAS INSERT LRI6E LRI6E shown with small backing

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE

More information

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11 SECURE-TEMP ASHT + USA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING........... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS...2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART............. 3 GENERAL INSTALLATION

More information

GE Monogram 36" Built-In Bottom-freezer Refrigerator

GE Monogram 36 Built-In Bottom-freezer Refrigerator SECTION 1 FLUSH INSET INSTLLTION SECTION 2 STNDRD INSTLLTION 1/4" FRMED PNELS 3/4" OVERLY PNELS OVERLL DIMENSIONS FLUSH INSET INSTLLTION 38" (96.5) 25 7/8" (65.7) 20 5/8" (52.4) 9 5/8" (24.4) * 8 (212.1)

More information

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

GAS FIREPLACES INSERTS.   GAS FIREPLACES INSERTS www.regency-fire.com GAS FIREPLACES INSERTS GAS FIREPLACES INSERTS WHY CHOOSE REGENCY? BEAUTIFUL HOME HEATING SOLUTIONS Regency Fireplace Products was founded over 35 years ago with a mission to produce

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES Model 49-240 Model 48LL1 Model 49-280 Model 49-480 Model 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance.

More information

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s DuraPlus Installation Instructions All-Fuel Chimney System C o m p l e t e V e n t i n g S o l u t i o n s A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO

More information

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

GAS FIREPLACES INSERTS.  GAS FIREPLACES INSERTS www.regency-fire.com GAS FIREPLACES INSERTS GAS FIREPLACES INSERTS WHY CHOOSE REGENCY? BEAUTIFUL HOME HEATING SOLUTIONS Regency Fireplace Products was founded over 35 years ago with a mission to produce

More information

Glass Front Sauna Room Assembly Manual

Glass Front Sauna Room Assembly Manual Glass Front Sauna Room Assembly Manual Classic Bench Version: 1.3 Note: Above images are for illustrative reference only and may differ from actual item. Parts List Exterior *For room with full glass wall

More information

The chimney must extend at least 2 above any part of the roof within 10 of it. A fireplace must have an intake combustion air duct installed to plan.

The chimney must extend at least 2 above any part of the roof within 10 of it. A fireplace must have an intake combustion air duct installed to plan. ROOF ASSEMBLY FURNACE VENT In the utility room or where the furnace is located, there is an access panel to inspect the furnace chimney pipe for gas fired units. Remove the cover and check to see that

More information

Dry Toilet, Version 2.0 June 17, 2015

Dry Toilet, Version 2.0 June 17, 2015 Dry Toilet, Version 2.0 June 17, 2015 Concrete Base When forming the concrete base, make sure it is same or slightly larger dimensions than the wooden base described below. The urine drain pipe is accommodated

More information

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE Featuring our NEW 10-Groove Design Aluminum Kits now packaged in new Slim-Line Suitcase style Cartons. Easier to Carry Easier to Stock Easier to Ship MODEL SFCL

More information

Installation Guide Classic Series Wood Siding

Installation Guide Classic Series Wood Siding Installation Guide Classic Series Wood Siding Please read the following instructions prior to beginning your installation. The following installation guidelines have been produced in accordance with the

More information

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes General Guidelines These instructions show one type of installation and are intended for the professional

More information

Jeep Cherokee Door XJ Set Part # Revision J

Jeep Cherokee Door XJ Set Part # Revision J Jeep Cherokee 84-96 4 Door XJ Set Part # 10911 Revision J 6-5-06 Step 1: Prior to Installation: A) Fit: Verify the fit of the flares to vehicle. (Some filing, sanding, or cutting may be necessary to ensure

More information

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= Attic Insulation Shield must be installed when the chimney passes from a lower living space into an upper living space. R&B #3802-07(CR) Menards 6 8 20

More information

Ekoroof LiteTile Dimensions

Ekoroof LiteTile Dimensions Ekoroof LiteTile Dimensions 7 3 3.5 Height 40 Width 20 Length Weight per Panel: 3 kg / 6.61 lbs 2 2 Area per panel 800 in / 5.55 ft 2 Panels per Square: 20 (including overlap, for a 100 ft covered area)

More information

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS MIROWV HOO OMINTION INSTLLTION INSTRUTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See Installation Requirements section for further

More information

Woodburning appliances price list

Woodburning appliances price list Woodburning appliances price list Front cover: Luna Diamond 1100 CR. Boley, Netherlands 1. Swipe 2. Driver (central unit). Motorunit with step engine (glass / sparkscreen / regulation combustion air supply)

More information

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL Masport Limited 1-37 Mt Wellington Highway Panmure Auckland 6 Ph: 09 571 1200 Fax: 09 571 5864 www.masport.com 2005 CONTENTS Ordering Information... Page 3 Freestanding

More information

Woodburning appliances price list

Woodburning appliances price list Woodburning appliances price list 1. Swipe 2. Driver (central unit). Motorunit with step engine (glass / sparkscreen / regulation combustion air supply) 4. Interface cables to motor 5. Temperature sensor

More information

gas fireplace inserts woo

gas fireplace inserts woo www.regency-fire.com woo gas fireplace inserts why choose Regency? Beautiful Home Heating Solutions Regency Fireplace Products was founded over 30 years ago with a mission to produce the finest fireplace

More information

gas fireplace inserts

gas fireplace inserts gas fireplace inserts why choose Regency? Beautiful Home Heating Solutions Regency Fireplace Products was founded almost 30 years ago with a mission to produce the finest fireplace products available anywhere.

More information

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS

MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS MIROWV HOO OMINTION INSTLLTION INSTRUTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See the Installation Requirements section for

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual IM770 Group: pplied ir Part Number: IM770 Date: pril 2003 Roof Curb for Skyline TM Outdoor ir Handlers 2013 Daikin pplied IM 770 Page 1 Table of Contents General Description...

More information

Installation Instructions. All-Fuel Chimney System. DuraPlus

Installation Instructions. All-Fuel Chimney System. DuraPlus Installation Instructions All-Fuel Chimney System DuraPlus A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

More information

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS MantelMount TMA Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS TM Thank you for choosing the MantelMount television wall mount. Please read this entire manual before

More information

RENU PANELING SYSTEM Installation Guide PLEASE READ GUIDE COMPLETELY BEFORE ASSEMBLY. Version 1.0 ALL STATED SIZES ARE NOMINAL DIMENSIONS.

RENU PANELING SYSTEM Installation Guide PLEASE READ GUIDE COMPLETELY BEFORE ASSEMBLY. Version 1.0 ALL STATED SIZES ARE NOMINAL DIMENSIONS. RENU PANELING SYSTEM Installation Guide Version 1.0 PLEASE READ GUIDE COMPLETELY BEFORE ASSEMBLY. ALL STATED SIZES ARE NOMINAL DIMENSIONS. Components Trim Track (TT) 1" x 1 3 4" (GER3TTAA): fastens to

More information

Mod-E Pro Electric L-Shaped Standing Desk

Mod-E Pro Electric L-Shaped Standing Desk The Height of Healthy Design Mod-E Pro Electric L-Shaped Standing Desk ASSEMBLY AND OPERATION MultiTable Mod-E Pro Electric L-Shaped Table Base PARTS AND TOOLS PLEASE REVIEW these instructions before beginning

More information

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan HowtoPlans.org DuraMax 8'x12 Garden Shed Plan Compare our Free vs. Premium Shed Plan This perfectly designed plan will guide you through the entire process of building your very own shed for any backyard

More information

15 Ft. x 39 Ft. Hoop House Construction

15 Ft. x 39 Ft. Hoop House Construction 15 Ft. x 39 Ft. Hoop House Construction Hoop House 15 Ft. x 39 Ft. HOOP HOUSE The Hoop House, Cold Frame and High Tunnel can be basically the same structure with minor changes to the design. The Hoop House

More information