TC106 Overview. Assessment of Human exposure to EMF. Don Heirman presenting for TC106 APEMC2016 TU-04. Shenzhen, China. May 2016
|
|
- Coral Stanley
- 6 years ago
- Views:
Transcription
1 INTERNATIONAL ELECTROTECHNICAL COMMISSION TC106 Overview Assessment of Human exposure to EMF Don Heirman presenting for TC106 APEMC2016 TU-04 Shenzhen, China May 2016 Copyright IEC, Geneva, Switzerland
2 TC106 Overview Purpose : To prepare international standards on measurement and calculation methods to assess human exposure to electric, magnetic and electromagnetic fields (0 Hz to 300 GHz). note: establishment of exposure limits is excluded New Strategic Business Plan TC106 September Plenary approved a 5 year Strategic Business Plan to 2020 which will see the internet of things, 5G and a truly connected world Market relevance TC106 standards will touch nearly every aspect of the domestic, industrial, consumer and business world by 2020 making our SBP very important to ensure we deliver efficient compliance assessment standards for the future technologies 2
3 TC106 Structure TC 106 chose a flat management structure - all convenors report directly to TC106 New leadership team commenced in
4 TC106 Work Program New Work Program & initiatives To ensure TC106 continues to deliver quality standards in a timely and efficient manner, the chairman introduced 3 key themes as a focus to help guide the new work program. Developing new ideas and initiatives in TC106 The need for efficiency and speed to market for standards development Collaboration and fostering new talent in TC106. TC106 will also participate in the IEC Young Professionals development program 4
5 Radiated Emission Measurement Projects: Wireless Communications Typical SAR Results Single Mode and Band* While most countries have adopted a regulatory SAR limit of 2.0 W/kg averaged over a 10 g of tissue volume, the limit in a few countries is 1.6 W/kg averaged over 1 g of tissue (e.g. USA) 5
6 TC106 New Work Program STRATEGIC OBJECTIVES 3-5 YEARS ACTIONS TO SUPPORT THE STRATEGIC OBJECTIVES TARGET DATE(S) TO COMPLETE THE ACTIONS Wireless Power Transfer Implement a compliance assessment standard for Wireless Power Transfer equipment and devices Establish Working Committee Identify assessment requirements & current gaps Determine if new IEC standard is required of if existing standard can be adapted Establish Working Group Technical report 5G Assessment Methods for Networks and Devices- Develop and Implement efficient test assessment methods for 5G technology including network equipment and devices Identify new assessment requirements for 5G Conduct gap analysis on existing IEC Standards Assign work to MT1 and MT3 based on identified requirements Revise standards as applicable 2018/19 Body Worn Device Compliance Review assessment methods and applicability of existing IEC Standards Review and update the MT1 business plan Revise standards as applicable 2017/18 6
7 TC106 New Work Program STRATEGIC OBJECTIVES 3-5 YEARS ACTIONS TO SUPPORT TARGET DATE(S) THE STRATEGIC OBJECTIVES TO COMPLETE THE ACTIONS Smart Sustainable Cities Monitor activities Review compliance assessment requirements and applicability of IEC Standards Identify gaps in current IEC standards EMF Compliance Assessment Guidefor teams developing standards/protocols to demonstrate RF exposure compliance Establish Ad Hoc Group in 2015 in Stresa Identify requirements and gaps for the EMF Guide on developing consistent and quality standards for assessment of human exposure 2016 complete draft EMF Guide and report back to TC106 plenary. Contact currents Address methods for assessment of contact current related to human exposures to electric, magnetic and electromagnetic fields; not including electrical shock. Establish working group Determine measuring methods for contact currents Determine an electrical circuit that represents the characteristics of human response 2015 Establish working group in Stresa (Italy) 2016 initial document: August
8 TC106 Project Highlights IEC Procedure to determine the specific absorption rate (SAR) for handheld devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) IEC Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)* Next Steps :2016 will be published early 2016 Unification of Parts 1 & 2 by May 2016 FDIS of Unified standard by end 2016 MT1 will prepare the request document with the technical background and rationale for a dual logo standard in due course. Dual logo is already voted in favor in ICES TC34 for IEC , -2 & -3 standards. IEC Human models, instrumentation, and procedures Part 3: Vector probe systems (Frequency range of 100 MHz to 6 GHz) Significant interest from SAR instrumentation manufacturers towards this activity IEC CD or TR/TS by mid 2016 IEC CDV by the end of 2016 FDIS during 2017 PT will consider writing a proposal for Dual logo standard 8
9 TC106 Project Highlights IEEE/IEC standard (General FDTD Methods) CDV was published for voting in Dec 2015 IEEE/IEC standard (Vehicle Mounted Antennas) CDV was published for voting in Dec 2015 IEEE/IEC standard (modelling of mobile phones) Possible date for CDV would be the end of Mar 2016 IEEE/IEC standard(finite Element Method) Very little activity/progress Andreas Christ new chairman Planed CD for IEC Determination of RF field strength and SAR in the vicinity of radio communication base stations for the purpose of evaluating human exposure CD2 September 2015 CDV May
10 TC106 New Work Groups Wireless Power Transfer Purpose - Implement a compliance assessment standard for Wireless Power Transfer equipment and devices Mr. Teruo Onishi was nominated Convenor Deliverable Technical Report by 2017 Contact currents Purpose - Address methods for assessment of contact current related to human exposures to electric, magnetic and electromagnetic fields; not including electrical shock Mr. Kenichi Yamazaki was nominated Convenor Deliverable Technical Report in
11 AHG6 EMF Guide for developing consistent and quality standards for the assessment of human exposure Purpose to provide guidenace for developing consistent and quality standards for the assessment of human exposure Current Status TC106 Ad Hoc Group 6 has been active to prepare base draft. The team met on 8th Oct 2015 where besides draft the generic approach of the Guide and structure of the Guide was discussed. The first draft was shared within AHG6 in May 2015 and the second draft in Oct Work program (draft by August 2016) There are four focusing groups in the team, Low frequency range, RF frequency range, uncertainties aspects & medical applications. The contributions are mostly discussed within smaller groups and incorporated in the darft after being discussed in the team. Most of the discussions are carried out during telcos and next f2f meeting is planned for May ACEC has agreed to own the guide Maintenance will be conducted by AdHoc Group 6 11
12 References TC106 Plenary Meeting Reports IEC TC106 MT1&IEC PT Activity & progress report Jafar Keshvari IEC MT1 & IEC PT ConvenerTC106 Plenary, TC106 Strategic Business Plan TC106 Plenary Meeting Report 12
13 INTERNATIONAL ELECTROTECHNICAL COMMISSION THANK YOU Copyright IEC, Geneva, Switzerland
TC106 Overview Assessment of Human exposure to EMF FR-PM-1-7
INTERNATIONAL ELECTROTECHNICAL COMMISSION TC106 Overview Assessment of Human exposure to EMF FR-PM-1-7 ACEC Update Chair: Mike Wood Copyright IEC, Geneva, Switzerland TC106 What s New Strong IEC / IEEE
More informationTechnical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure
Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure International Electrotechnical Commission Michel Bourdages Secretary International
More informationRecent Trends of TC 77 and its Subcommittees
INTERNATIONAL ELECTROTECHNICAL COMMISSION Recent Trends of TC 77 and its Subcommittees William Radasky presenting for Hiroyuki Ohsaki TC 77 Chair APEMC Symposium Seoul, June 2017 Copyright IEC, Geneva,
More informationThis is a preview - click here to buy the full publication
TECHNICAL REPORT IEC TR 63170 Edition 1.0 2018-08 colour inside Measurement procedure for the evaluation of power density related to human exposure to radio frequency fields from wireless communication
More informationRABC Meeting. May Update on ISED s Regulatory Standards Activities - ICES & RF Exposure EDRMS:
EDRMS: 877930 Update on ISED s Regulatory Standards Actiities - ICES & RF Exposure RABC Meeting May 2018 Hughes Nappert Manager, Regulatory Standards Innoation, Science and Economic Deelopment Building
More informationTariq H Alamri ITU-T Study Group 5 Vice-Chairman Communications and Information Technology Commission (CITC), Saudi Arabia
Tariq H Alamri ITU-T Study Group 5 Vice-Chairman Communications and Information Technology Commission (CITC), Saudi Arabia 8 th ITU Symposium on ICTs, the Environment and Climate Change Turin, Italy, 9
More informationMIC MRA WORSKHOP 2015 Fast SAR Trends, Standardization & Regulatory Status. Dr. Benoît Derat, CEO, ART-Fi SAS
MIC MRA WORSKHOP 2015 Fast SAR Trends, Standardization & Regulatory Status Dr. Benoît Derat, CEO, ART-Fi SAS New Wireless Technologies & Increase in SAR Testing Matrix Wireless devices with more complex
More informationIEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec
IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec represents the most complete resource available for professional engineers looking for best practices
More informationRecent Trends of TC 77 and its Subcommittees FR-PM-1-3
INTERNATIONAL ELECTROTECHNICAL COMMISSION Recent Trends of TC 77 and its Subcommittees FR-PM-1-3 Dr. William Radasky presenting for Dr. Hiroyuki Ohsaki, TC 77 Chair IEEE EMC Symposium Long Beach, California
More informationCOMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT
COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area
More informationEU Standards dedicated Mobile and Base Station
EU Standards dedicated Mobile and Base Station Joe Wiart Whist Lab Orange Labs & Telecom Institute laboratory Convenor of the CENELEC TC106x WG1 Gaborone 2010 CENELEC Composed of the National Electrotechnical
More informationTECHNICAL COMMITTEE No. 100: AUDIO, VIDEO AND MULTIMEDIA SYSTEMS AND EQUIPMENT
100(Tel Aviv/Secretariat)30 For IEC use only 2010-10-22 INTERNATIONAL ELECTROTECHNICAL COMMISSION TECHNICAL COMMITTEE No. 100: AUDIO, VIDEO AND MULTIMEDIA SYSTEMS AND EQUIPMENT Decision list of Fifteenth
More informationThis is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL ELECTROTECHNICAL COMMISSION CISPR 22 Fifth edition 2005-04 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Information technology equipment Radio disturbance characteristics Limits
More informationThis is a preview - click here to buy the full publication. Exposure assessment methods for wireless power transfer systems
TECHNICAL REPORT IEC TR 62905 Edition 1.0 2018-02 colour inside Exposure assessment methods for wireless power transfer systems INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 17.220.20 ISBN 978-2-8322-5350-2
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 11452-9 First edition 2012-05-15 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 9: Portable transmitters
More informationANSI C Testing unintentional emitters
ANSI C63.4-2014 Testing unintentional emitters Presented by Don Heirman President Don Lincroft, New Jersey USA Chair, ANSI C63.4 Working Group March 2015 Slide 1 Use of colors on slides Generally text
More informationCanadian Regulatory Requirements for Radio Frequency Exposure Compliance of Radiocommunication Apparatus and Installations
Canadian Regulatory Requirements for Radio Frequency Exposure Compliance of Radiocommunication Apparatus and Installations Josette Gallant Senior EMC/EMI Bioelectromagnetics Engineer Industry Canada 17
More information5G Implementation in Europe and CIS. Setting the scene on EMF and 5G. István Bozsóki
5G Implementation in Europe and CIS Setting the scene on EMF and 5G István Bozsóki Head of Spectrum Management and Broadcasting Division International Telecommunication Union ITU activities on EMF ITU-T
More informationChallenges in standardization related to EMF compliance above 6 GHz
Challenges in standardization related to EMF compliance above 6 GHz BioEM 2018 pre conference workshop June 24, 2018 Davide Colombi, Ericsson Research Challenges in EMF compliance standardization for devices
More informationBefore the Federal Communications Commission Washington, D.C
Before the Federal Communications Commission Washington, D.C. 20554 In the Matter of ) ) Proposed Changes in the Commission s ) ET Docket No. 03-137 Rules Regarding Human Exposure to ) Radiofrequency Electronic
More informationITU-D activities on EMF
ITU-D activities on EMF 2 November 2017, Rome István Bozsóki Head of TND Division ITU/BDT/IEE ITU framework on ElectroMagnetic Fields (EMF) 1. ITU Plenipotentiary Resolution 176 (Rev. Busan, 2014): Human
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61097-2 Second edition 2002-09 Global maritime distress and safety system (GMDSS) Part 2: COSPAS-SARSAT EPIRB Satellite emergency position indicating radio beacon operating on
More informationNumerical Assessment of Specific Absorption Rate in the Human Body Caused by NFC Devices
Second International Workshop on Near Field Communication Numerical Assessment of Specific Absorption Rate in the Human Body Caused by NFC Devices S. Cecil, G. Schmid, K. Lamedschwandner EMC&Optics Seibersdorf
More informationEMF risk for operators mounting, adjusting and maintaining base stations
Environmentalist (2007) 27:545 549 DOI 10.1007/s10669-007-9062-3 EMF risk for operators mounting, adjusting and maintaining base stations T. Shalamanova Æ I. Iliev Æ M. Ivanova Æ M. Israel Published online:
More informationAKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY VERKOTAN OY VERKOTAN LTD.
T287/M04/2018 Liite 1 / Appendix 1 Sivu / Page 1(6) AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY VERKOTAN OY VERKOTAN LTD. Tunnus Code Laboratorio Laboratory Osoite Address www www T287
More informationTesting activities of NCA Type Approval Testing labs and key challenges. Kofi Ntim Yeboah-Kordieh National Communications Authority
Testing activities of NCA Type Approval Testing labs and key challenges Kofi Ntim Yeboah-Kordieh National Communications Authority Contents Legal Authority Benefits of Type Approval NCA Equipment Authorization
More informationProduct Compliance Assessments of Low Power Radio Base Stations with Respect to Whole-Body Radiofrequency Exposure Limits
Product Compliance Assessments of Low Power Radio Base Stations with Respect to Whole-Body Radiofrequency Exposure Limits Björn Thors, Lovisa Nord, Davide Colombi, and Christer Törnevik 1 Ericsson Research,
More informationAustralian/New Zealand Standard
AS/NZS CISPR 11:2011 IEC CISPR 11, Ed. 5.1 (2010) AS/NZS CISPR 11:2011 Australian/New Zealand Standard Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and
More informationIEEE ICES Exposure Limits Above 6 GHz
Mobile Manufacturers Forum Workshop EMF Exposure Limits and Compliance Assessment of Future Wireless Devices Above 6 GHz Exposure Limits Above 6 GHz Dr. C-K. Chou* TC95 Chairman International Committee
More informationAustralian/New Zealand Standard
AS/NZS 2772.2:2011 AS/NZS 2772.2:2011 Australian/New Zealand Standard Radiofrequency fields Part 2: Principles and methods of measurement and computation 3 khz to 300 GHz AS/NZS 2772.2:2011 This Joint
More informationInternational Conference KNOWLEDGE-BASED ORGANIZATION Vol. XXIII No
International Conference KNOWLEDGE-BASED ORGANIZATION Vol. XXIII No 3 2017 ELECTROMAGNETIC DOSIMETRY OF RADIOFREQUENCY PORTABLE TRANSCEIVERS USED IN FRONT OF THE FACE Simona MICLĂUȘ*, Ionel DUMBRAVĂ**,
More informationNEW IEEE C RF SAFETY STANDARD
NEW IEEE C95.1-2005 RF SAFETY STANDARD C-K. Chou, Ph.D. IEEE International Committee on Electromagnetic Safety Technical Committee 95, Subcommittee 4 New York, New York, USA. IEEE RF Safety Standard History
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60268-3 Third edition 2000-08 Sound system equipment Part 3: Amplifiers Equipements pour systèmes électroacoustiques Partie 3: Amplificateurs IEC 2000 Copyright - all rights
More informationNovember 3, Saw Sun Hock, Giorgi Bit-Babik, Ph.D., and Antonio Faraone, Ph.D. Motorola Solutions EME Research Lab, Plantation, Florida
COMPUTATIONAL EME COMPLIANCE ASSESSMENT OF THE DIGITAL VEHICULAR REPEATER (DVR UHF), MOBEXCOM (DQPMDVR4000P, DQPMDVR5000P, DQPMDVR6000P) AND COMPANION APX SERIES MODEL M37TSS9PW1AN MOBILE RADIO. November
More informationEN EMF REPORT For. Two way radio Model No.: RT-5R
Report No.: B-E16049599 Page 1 of 9 EN 62311 EMF REPORT For Zhengzhou Eshow Import and Export Trade Co., Ltd. Two way radio Model No.: RT-5R Model No. Trade Name Prepared for Address : RT-5R : N/A : Zhengzhou
More informationEffects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions
Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1
More informationIEC Vector Probe-Array SAR Measurement
IEC 62209-3 Vector Probe-Array SAR Measurement MIC MRA International Workshop 2016 Benoît Derat Introduction Peak spatial-average 1g and 10g Specific Absorption Rate measurement is key to demonstrate conformity
More informationITU-T activities on Human Exposure to Electromagnetic Fields (EMFs)
ITU-T activities on Human Exposure to Electromagnetic Fields (EMFs) 8th Green Standards Week 9-12 April 2018, Zanzibar, Tanzania Dr. Fryderyk Lewicki Chairman of Working Party 1, ITU-T SG5 Orange Polska,
More informationFar-Field Effects with Human Head Evaluation of EM Emission
Proceedings of the 5th WSEAS Int. Conf. on Applied Electromagnetics, Wireless and Optical Communications, Corfu, Greece, August 3, 5 (pp471) Far-Field Effects with Human Head Evaluation of Emission SHENG-YI
More informationPAR FORM SCC-34/SC-2/WG-1
PAR FORM SCC-34/SC-2/WG-1 1. Sponsor Date of Request [January 21, 1998] 2. Assigned Project Number [P1528] 3. PAR Approval Date [03/19/98] 4. Project Title, Copyright Agreement and Working Group Chair
More informationElectromagnetic Fields, Mobile Telephones and Health
Electromagnetic Fields, Mobile Telephones and Health Dr. Matti Rajala European Commission Directorate General for Health and Consumer Protection - Luxembourg Council Recommendation 12th July (1999/519/EC)
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62153-4-11 Edition 1.0 2009-08 colour inside Metallic communication cable test methods Part 4-11: Electromagnetic compatibility (EMC) Coupling attenuation or screening attenuation
More informationMOBILE PHONE EM EXPOSURE STUDY ON INHOMOGENEOUS HUMAN MODELS CONSIDERING DIFFERENT HAND POSITIONS
JAE, VOL. 19, NO. 1, 2017 JOURNAL OF APPLIED ELECTROMAGNETISM MOBILE PHONE EM EXPOSURE STUDY ON INHOMOGENEOUS HUMAN MODELS CONSIDERING DIFFERENT HAND POSITIONS V. Jeladze, T. Nozadze, R. Zaridze, M. Prishvin,
More informationThis is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL ELECTROTECHNICAL COMMISSION CISPR 11 Edition 4.1 2004-06 Edition 4:2003 consolidated with amendment 1:2004 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Industrial, scientific and
More informationExperimental Compliance Testing of Telephony Base Stations, Broadcast Stations, and General Mobile Transmitters
Experimental Compliance Testing of Telephony Base Stations, Broadcast Stations, and General Mobile Transmitters Sven Kühn Foundation for Research on Information Technologies in Society ETH Zurich, Switzerland
More informationINTERNATIONAL. Medical device software Software life cycle processes
INTERNATIONAL STANDARD IEC 62304 First edition 2006-05 Medical device software Software life cycle processes This English-language version is derived from the original bilingual publication by leaving
More informationAppendix for the Report Dosimetric Assessment of the Portable Device Selex Elsag S.p.A. PUMA T3 plus (FCC ID: X5Y )
The Testcenter facility Dosimetric Test Lab within IMST GmbH is accredited by the German National Deutsche Akkreditierungsstelle GmbH (DAkkS) for testing according to the scope as listed in the accreditation
More informationRF Radiation Safety Training
RF Radiation Safety Training Public Three-Day Courses Custom Corporate Training Programs Training Videos RF Radiation You can t see it, smell it, hear it, or touch it. Yet the more we learn about it, the
More informationFryderyk Lewicki, ITU-T SG5, Vice chairman WP2 Orange Polska, Poland
ITU Symposium on ICT, Environment and Climate Change (Kuala Lumpur, Malaysia, 21 April 2016) MEASUREMENTS AND CALCULATIONS OF EMF Fryderyk Lewicki, ITU-T SG5, Vice chairman WP2 Orange Polska, Poland Introduction
More informationSpecific Absorption Rate (SAR) Overview Presented by Mark Jenkins and Vina Kerai. TÜV SÜD Product Service GmbH
Specific Absorption Rate (SAR) Overview Presented by Mark Jenkins and Vina Kerai TÜV SÜD Product Service GmbH Overview Introduction to Specific Absorption Rate (SAR) Why consider it? What is it? Legislative
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62092 First edition 2001-08 Utrasonics Hydrophones Characteristics and calibration in the frequency range from 15 MHz to 40 MHz Ultrasons Hydrophones Caractéristiques et étalonnage
More informationMaking sure of a healthy environment. Narda EMF Monitors. Improving safety in electromagnetic fields
Making sure of a healthy environment Narda EMF Monitors Improving safety in electromagnetic fields EMF: The invisible radiation that permeates our world Rapid growth in complex infrastructures is taking
More informationBiljana Tanatarec Doron Net d.o.o. ISO/HZN National Workshop on Social Responsibility Zagreb, 9 10 September 2010
Biljana Tanatarec Doron Net d.o.o. ISO/HZN National Workshop on Social Responsibility Zagreb, 9 10 September 2010 Introduction Working in Doron Net d.o.o. Head of DN Laboratory Doron Net is a member of
More informationGUIDE 75. Strategic principles for future IEC and ISO standardization in industrial automation. First edition
GUIDE 75 First edition 2006-11 Strategic principles for future IEC and ISO standardization in industrial automation Reference number ISO/IEC GUIDE 75:2006(E) GUIDE 75 First edition 2006-11 Strategic principles
More informationFrequency ranges for operation of non-beam wireless power transmission systems
Recommendation ITU-R SM.2110-0 (09/2017) Frequency ranges for operation of non-beam wireless power transmission systems SM Series Spectrum management ii Rec. ITU-R SM.2110-0 Foreword The role of the Radiocommunication
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
INTERNATIONAL ELECTROTECHNICAL COMMISSION CISPR 14-1 Edition 4.2 2002-10 Edition 4:2000 consolidated with amendments 1:2001 and 2:2002 INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Electromagnetic
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61842 First edition 2002-03 Microphones and earphones for speech communications Reference number IEC 61842:2002(E) Publication numbering As from 1 January 1997 all IEC publications
More informationHAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION
HAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION IS IT SAFE TO USE A CELL PHONE, BLUE TOOTH, AND WIFI HOTSPOTS??? Learning Objectives Non-Ionizing RF Radiation vs. Ionizing Radiation Biological effects
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 11451-3 Third edition 2015-06-01 Road vehicles Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 3: On-board transmitter simulation
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60728-11 1997 AMENDMENT 1 2000-10 Amendment 1 Cabled distribution systems for television and sound signals Part 11: Safety Amendement 1 Systèmes de distribution par câbles destinés
More informationHealth Test Report. Report No.: AGC EH01 EN 62311:2008 EN 50566:2013. Attestation of Global Compliance (Shenzhen) Co., Ltd.
Page 1 of 9 Health Test Report Report No.: AGC01039140302EH01 TEST NAME : 1999/5/EC R&TTE Directive PRODUCT DESIGNATION : Mobile radio BRAND NAME : TYT MODEL NAME : TH 9800, TH 9800D, TH 7800, TH 7900
More informationThis is a preview - click here to buy the full publication TECHNICAL REPORT
TECHNICAL REPORT IEC TR 61967-4-1 First edition 2005-02 Integrated circuits Measurement of electromagnetic emissions, 150 khz to 1 GHz Part 4-1: Measurement of conducted emissions 1 Ω/150 Ω direct coupling
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61993-1 First edition 1999-04 Maritime navigation and radiocommunication equipment and systems Part 1: Shipborne automatic transponder system installation using VHF digital selective
More informationTechnical Specifications for Broadband Terminal Equipment of Mobile Broadband Business
Technical Specifications of the Telecommunications Land Mobile 10 (PLMN10) Inspection Requirements Date: 12 March 2018 Technical Specifications for Broadband Terminal Equipment of Mobile Broadband Business
More informationThis document is a preview generated by EVS
CONSOLIDATED VERSION CISPR TR 16-4-4 Edition 2.1 2017-06 colour inside INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Specification for radio disturbance and immunity measuring apparatus and methods
More informationRadio Frequency Exposure Test Report
Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified)
More informationThis is a preview - click here to buy the full publication
CONSOLIDATED VERSION CISPR TR 16-4-4 Edition 2.1 2017-06 colour inside INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Specification for radio disturbance and immunity measuring apparatus and methods
More informationPart 3: Image quality classes
INTERNATIONAL STANDARD ISO 19232-3 Second edition 2013-06-15 Non-destructive testing Image quality of radiographs Part 3: Image quality classes Essais non destructifs Qualité d image des radiogrammes Partie
More informationTECHNICAL COMMITTEE No. 100: AUDIO, VIDEO AND MULTIMEDIA SYSTEMS AND EQUIPMENT
For IEC use only 100(Tokyo/Secretariat)43 2014-11-09 INTERNATIONAL ELECTROTECHNICAL COMMISSION TECHNICAL COMMITTEE No. 100: AUDIO, VIDEO AND MULTIMEDIA SYSTEMS AND EQUIPMENT Resolution list of the twentieth
More informationSAR Test Summary. Maximum Reported 1g SAR FCC. Harris Corporation 221 Jefferson Ridge Parkway Lynchburg, VA, USA. XL-200P w/ LTE.
Test Report Serial Number: Test Report Date: Project Number: 45461356NAR1.0 7 October 2016 1359 SAR Test Summary Applicant: Harris Corporation 221 Jefferson Ridge Parkway Lynchburg, VA, 24501 USA FCC ID:
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61000-2-13 First edition 2005-03 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 2-13: Environment High-power electromagnetic (HPEM) environments Radiated and
More informationEN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD
EN 62479:2010 ASSESSMENT REPORT For WIN CHANNEL ELECTRONICS (HK) CO., LTD No.1, Shangxing Road, Shangjiao, Changan Town, Dongguan, Guangdong, China Tested Model: 318EU Multiple Models: 73500, 73506, FREECOMM
More informationHealth Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1
Health Issues 18.1 Health Issues Introduction Let s face it - radio waves are mysterious things. Especially when referred to as electromagnetic radiation the concept makes many people nervous. In this
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 15848-2 Second edition 2015-06-01 Industrial valves Measurement, test and qualification procedures for fugitive emissions Part 2: Production acceptance test of valves Robinetterie
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61993-2 First edition 2001-12 Maritime navigation and radiocommunication equipment and systems Automatic identification systems (AIS) Part 2: Class A shipborne equipment of the
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61726 Second edition 1999-11 Cable assemblies, cables, connectors and passive microwave components Screening attenuation measurement by the reverberation chamber method Câbles,
More informationWLAN. Date: 20 October 2016
WLAN Date: 20 October 2016 A wireless local area network (WLAN) allows computers and laptops to be connected to each other, to peripheral devices (printers, scanners etc.) and to an Internet access point.
More informationNumerical Modelling for Evaluation of Biological Effects Due to High Frequency Radiations in Indoor Environment
PIERS ONLINE, VOL. 6, NO. 3, 2010 247 Numerical Modelling for Evaluation of Biological Effects Due to High Frequency Radiations in Indoor Environment M. Cacciola, G. Megali, D. Pellicanò, M. Versaci, and
More informationGEISLAVARNIR RÍKISINS ICELANDIC RADIATION SAFETY AUTHORITY
GEISLAVARNIR RÍKISINS ICELANDIC RADIATION SAFETY AUTHORITY Danish National Board of Health (Sundhedsstyrelsen) Finnish Radiation and Nuclear Safety Authority (Säteilyturvakeskus, STUK) Icelandic Radiation
More informationTABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3
Revision History Version Issue Date Revisions Rev. 01 June 30, 2014 First edition TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 Identification of the Testing Laboratory... 3 1.2 Identification of the
More informationHuman Exposure Requirements for R&TTE and FCC Approval
Human Exposure Requirements for R&TTE and FCC Approval Derek Y. W. LEUNG Founding and Committee Member of EMC Chapter- IEEE-HK Requirements of Non-Specific Short Range Device (SRD) for CE Marking Radio
More informationEMF Compliance Assessments of 5G Devices
EMF Compliance Assessments of 5G Devices Serge Pfeifer, IT IS Foundation Esra Neufeld, IT IS Foundation Eduardo Carrasco, IT IS Foundation Andreas Christ, IT IS Foundation Myles Capstick, IT IS Foundation
More informationC E R T I F I C A T E OF C A L I B R A T I O N
NCL CALIBRATION LABORATORIES Calibration File No.: 1233 Client.: APREL C E R T I F I C A T E OF C A L I B R A T I O N It is certified that the equipment identified below has been calibrated in the NCL
More informationArea Network Applications] Notice: This document has been prepared to assist the IEEE P It is
Project: IEEE P802.15 Working Group for Wireless Personal Area Networks N (WPANs) Submission Title: [RF Safety Considerations for Body Area Network Applications] Date Submitted: [] Source: [Kamya Yekeh
More informationISO/IEC INTERNATIONAL STANDARD. Information technology Security techniques Privacy framework
INTERNATIONAL STANDARD ISO/IEC 29100 First edition 2011-12-15 Information technology Security techniques Privacy framework Technologies de l'information Techniques de sécurité Cadre privé Reference number
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 11452-8 Second edition 2015-06-01 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 8: Immunity to magnetic
More informationAS/NZS CISPR 14.1:2013
AS/NZS CISPR 14.1:2013 CISPR 14-1, Ed.5.2 2011, IDT Australian/New Zealand Standard Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission
More informationBulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results
Immunity Testing: radiated immunity 41 Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results Immunity Testing: radiated immunity 42 Bulk Current
More informationISO/IEC INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 24730-62 First edition 2013-09-01 Information technology Real time locating systems (RTLS) Part 62: High rate pulse repetition frequency Ultra Wide Band (UWB) air interface
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60489-1 1983 AMENDMENT 2 1999-05 Amendment 2 Methods of measurement for radio equipment used in the mobile services Part 1: General definitions and standard conditions of measurement
More informationSERIES K: PROTECTION AGAINST INTERFERENCE
International Telecommunication Union ITU-T K.49 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2005) SERIES K: PROTECTION AGAINST INTERFERENCE Test requirements and performance criteria for voice
More informationRoad vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy. Part 3:
INTERNATIONAL STANDARD ISO 11452-3 Third edition 2016-09-01 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 3: Transverse electromagnetic
More informationWHITEPAPER WHITEPAPER
WHITEPAPER WHITEPAPER Radio Frequency Emissions Analysis of Radio Frequency Exposure Associated with Silver Spring Networks Advanced Metering Devices Executive Summary This document provides information
More informationIS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation
INTERNATIONAL STANDARD IS0 9613-2 First edition 1996-I 2-l 5 Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation Acoustique -Attenuation du son lors de
More informationAntennas and Propagation for Body-Centric Wireless Communications
Antennas and Propagation for Body-Centric Wireless Communications Peter S. Hall Yang Hao Editors ARTECH H O U S E BOSTON LONDON artechhouse.com Preface CHAPTER 1 Introduction to Body-Centric Wireless Communications
More informationSAR Evaluation Considerations for Handsets with Multiple Transmitters and Antennas
Evaluation Considerations for Handsets with Multiple Transmitters and Antennas February 2008 Laboratory Division Office of Engineering and Techlogy Federal Communications Commission Introduction This document
More informationIEC Second Edition
Electromagnetic Compatibility of Medical Electrical Equipment Second Edition Prepared by Mr. James Conrad Presented by Dr. William A. Radasky 1 Second Edition Updates first edition on standards developed
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60601-2-18 1996 AMENDMENT 1 2000-07 Amendment 1 Medical electrical equipment Part 2-18: Particular requirements for the safety of endoscopic equipment Amendement 1 Appareils
More informationISO 262 INTERNATIONAL STANDARD. ISO general purpose metric screw threads Selected sizes for screws, bolts and nuts
INTERNATIONAL STANDARD ISO general purpose metric screw threads Selected sizes for screws, bolts and nuts A ISO 6 Second edition 998--5 Filetages métriques ISO pour usages généraux Sélection de dimensions
More informationReport On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW
Report On RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW Document 75908189 Report 04 Issue 2 March 2010 TUV Product Service
More information